Loading...
HomeMy WebLinkAbout2020-02-05; Planning Commission; ; SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS Item No. Application complete date: November 21, 2019 P.C. AGENDA OF: February 5, 2020 Project Planner: Cliff Jones Project Engineer: Tecla Levy SUBJECT: SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS – Request for approval of a Site Development Plan and Hillside Development Permit to construct a four-story, 26-unit residential apartment project which includes four inclusionary housing units, on vacant property generally located along the west side of Viejo Castilla Way between Navarra Drive and Pirineos Way within Local Facilities Management Zone 6. The City Planner has determined that this project is exempt from the requirements of the California Environmental Quality Act (CEQA) pursuant to Section 15332 “In-Fill Development Projects” of the State CEQA Guidelines and will not have any adverse significant impact on the environment. I. RECOMMENDATION That the Planning Commission ADOPT Planning Commission Resolution No. 7358 APPROVING Site Development Plan SDP 2018-0022 and Hillside Development Permit HDP 2018-0006 based upon the findings and subject to the conditions contained therein. II. PROJECT DESCRIPTION AND BACKGROUND The project consists of grading two existing lots and the construction of a 26-unit residential apartment project consisting of three, three-story buildings and two, four-story buildings. The 0.86-acre project site consists of two legal parcels that were previously graded. The lots are conditioned to be merged prior to development. The site fronts Viejo Castilla Way and is the remaining vacant site to be developed in the neighborhood. Previously, in September 2006, the Planning Commission approved a 15-unit residential condominium project on the site. However, this previous approval expired, and the project site remains vacant. A narrow strip of dense, shrubby habitat classified as unoccupied, disturbed scrub oak chaparral habitat was identified in the applicant’s Biological Technical Report for this property. This habitat runs in a diagonal direction across the property from northwest to southeast and is 0.14 acres in size. This scrub vegetation is of low habitat value, being isolated on the property and surrounded by development on all sides. Although the project will impact this native habitat, the impact has already been analyzed, anticipated, and authorized by the City of Carlsbad Habitat Management Plan (HMP). The habitat being impacted by this project is not a part of, nor of any biological value to, the HMP citywide habitat preserve system, and will not jeopardize the existence or survival of any rare, threatened or endangered plant or animal species. The impact will be mitigated through the payment of habitat in lieu mitigation fees in accordance with the adopted HMP. 1 SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 2 Grading for the proposed project includes 4,000 cubic yards (c.y.) of cut, 500 c.y. of fill, with 3,500 c.y. of export. The grading results in two, split level pads that are slightly lower in height than existing. A grading permit is required for the project. The project will take access off of Viejo Castilla Way which is a fully improved public street with curb, gutter, and sidewalk. Two driveways are provided off Viejo Castilla Way to access the two-car garages, covered parking spaces, trash and utility areas. The site design consists of five separate buildings surrounding a central courtyard. Buildings “A” and “B” are three stories in height, each containing three units. Each unit has a private roof deck overlooking the golf course, and a two-car garage. Buildings “C” and “D” are four stories in height, each containing six units, with two-car garages. Building “E” is three stories in height, containing eight units. The four, two-bedroom units are assigned two covered parking spaces each and the four, one-bedroom units are assigned one covered parking space each. One surplus parking space is provided with the project. A breakdown of each type of unit is summarized in Table 1 below. TABLE 1 – DETAILS FOR UNIT TYPE Unit # Quantity Size Bedroom/Bathrooms Parking Spaces Per Unit A1, A2, A3 3 1,215 – 3,008 SF 3/3 2 B1, B2, B3 3 1,954 – 2,230 SF 3/3 2 C1, C2 2 1,519 – 1,522 SF 3/4 2 C3, C4, C5, C6 4 1,509 – 1,531 SF 3/3 2 D1, D2 2 1,504 – 1,520 SF 3/4 2 D3, D4, D5, D6 4 1,515 – 1,533 SF 3/3 2 E1 (affordable) 1 992 SF 2/2 2 E4, E5, E8 3 992-1054 SF 2/2 2 E2, E3, E6 (affordable) 3 590 – 592 SF 1/1 1 E7 1 592 SF 1/1 1 Buildings “A” and “B” are located at the southern end of the site, abutting the golf course, and are approximately 34 feet in height as measured from the new, lower, finished grade. Architectural features extend to approximately 39 feet in height. Buildings “C” and “D” are located in the middle of the site and are approximately 48 feet in height as measured from the new, lower, finished grade. Architectural features extend to approximately 51 feet in height. Building “E” is located at the north of the site, abutting a three-story residential development at the corner of Viejo Castilla Way and Navarra Drive, and is approximately 32 feet in height as measured from the new, lower, finished grade. Architectural features extend to approximately 37 feet in height. The façades consist of a series of private balconies alternating between living spaces that are designed to maximize access to sun and views offered by the lot’s location adjacent to the golf course. A common landscaped courtyard with seating areas, a barbeque, and a fire pit is located at the center of the site. Parking areas are concealed from view within private garages or by buildings. A new drainage system will be constructed along the westerly and northerly property lines as part of the proposed project to convey site runoff to the Viejo Castilla Way right-of-way, in compliance with the City's National Pollutant Discharge Elimination System Permit. This new drainage system will reduce the total volume of runoff to Viejo Castilla Way. SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 3 Pursuant to Chapter 21.86 of the Carlsbad Municipal Code (CMC), the applicant is requesting a 35 percent density bonus which requires a minimum of 20 percent of the base units as inclusionary (i.e., rent- restricted) units affordable to “low-income households.” With this density bonus, the maximum number of units allowed for the 0.86-acre site is 27 units with four units required to be affordable to “low-income” households. The project is proposing 26 units, which is one unit less than what is allowed per density bonus law for providing four low-income units. The project is also required to comply with the city’s inclusionary housing requirement of 15 percent, or three, affordable units, which is satisfied though the provision of the four “low-income” units. Including the density bonus/inclusionary units, the 26-unit project has a proposed density of 30.3 dwelling units per acre. As part of the density bonus request for providing 20 percent of the base units affordable to “low-income households,” up to two incentives or concessions may be requested (CMC Section 21.86.050) and an unspecified number of waivers. Accordingly, the applicant is requesting: 1) two incentives which are the allowance for increased building height and units from the city’s Excess Dwelling Unit Bank; and 2) a wavier to allow the rear yard stairs to encroach into the rear setback area. Section “A” provides a detailed discussion on the density bonus request. Table 2 below includes the General Plan Land Use designations, zoning and current land uses of the project site and surrounding properties. TABLE 2 – SURROUNDING LAND USE Location General Plan Designation Zoning Current Land Use Site R-23 Residential Residential Density – Multiple (RD-M) Vacant North R-23 Residential RD-M Multi-Family Residential South Open Space (OS) Planned Community (PC) Golf Course East R-23 Residential RD-M Multi-Family Residential West R-23 Residential RD-M Multi-Family Residential Although not required for residential development less than fifty units, the applicant voluntarily chose to conduct enhanced stakeholder public outreach. The applicant’s team met with surrounding residents, property owners, and interested parties on September 25, October 24 and December 5, 2019. Public concerns included but were not limited to parking, traffic, density, height, and views. The applicant explained that the project is meeting parking requirements, is allowed additional height and density per Density Bonus Law, the additional traffic has negligible impact upon the intersection of Viejo Castilla Way and La Costa Avenue, and prepared additional visual simulations to demonstrate the project’s impact upon adjacent development. Public comments received and the applicant’s response to the comments are provided within the attached Enhanced Stakeholder Outreach Report (Attachment 4). III. ANALYSIS The project is subject to the following regulations: A. R-23 Residential General Plan Land Use Designation and Density Bonus Ordinance (CMC Chapter 21.86); B. Residential Density – Multiple (RD-M) Zone (CMC Chapter 21.24); C. Qualified Development Overlay Zone (CMC Chapter 21.06); D. Hillside Development Ordinance (CMC Chapter 21.95); E. Inclusionary Housing Ordinance (CMC Chapters 21.85); and SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 4 F. Growth Management Ordinance (CMC Chapter 21.90) and Local Facilities Management Plan Zone 6. The recommendation for approval of this project was developed by analyzing the project’s consistency with the applicable regulations and policies. The project’s compliance with each of the above regulations is discussed in detail in the sections below. A. R-23 Residential General Plan Land Use Designation and Density Bonus Ordinance (CMC Chapter 21.86) The General Plan Land Use designation for the property is R-23 Residential, which allows residential development at a density range of 15-23 dwelling units per acre (du/ac) with a Growth Management Control Point (GMCP) of 19 du/ac. Table 3 below identifies the permissible density range for properties designated R-23 Residential. TABLE 3 – DENSITY Gross Acres Net Acres R-23 Residential Allowable Density 0.86 0.86 Range: 15-23 du/ac Minimum: 15 x 0.86 = 13 dwelling units GMCP: 19 x 0.86 = 16 dwelling units Maximum: 23 x 0.86 = 20 dwelling units The proposed project entails a request to construct a 26-unit apartment project. As summarized above, the maximum number of units for a 0.86-acre parcel at 23 dwelling units per acre is 20 dwelling units. In order to construct 26 units, the applicant is requesting approval of a density bonus pursuant to CMC Chapter 21.86, the Residential Density Bonus and Incentives or Concessions Ordinance. CMC Chapter 21.86 was established as a means to implement state law and the goals, objectives and policies of the Housing Element of the General Plan which includes the provision to provide housing affordable to lower- and moderate-income households. Specifically, the applicant is requesting a 35 percent density bonus pursuant to Table A of CMC Section 21.86.040. In exchange for the 35 percent density bonus, the applicant is required to designate 20 percent of the base number of units, or four units, as inclusionary units. The inclusionary apartments are required to be rent-restricted and affordable to “low-income households.” Pursuant to CMC Section 21.86.020, a “low-income household” is defined as a household whose gross income is more than fifty percent but does not exceed eighty percent of the median income for San Diego County as determined annually by the U.S. Department of Housing and Urban Development. CMC Chapter 21.85 requires a minimum of 15 percent inclusionary units or three inclusionary units for projects requesting an incentive (increased building height and excess dwelling units). However, CMC Chapter 21.86 requires 20 percent, or four, inclusionary units for this proposed project. The project is satisfying both requirements by providing four inclusionary housing units. Summary of density bonus request: Base maximum density: 23 dwelling units per acre Base maximum units: 0.86 acres x 23 = 20 dwelling units (round up per CMC Section 21.86.040(G)) (15% or three units required to be inclusionary units) 35% density bonus: 20 + 35% = 27 units (round up per CMC Section 21.86.040(G)) SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 5 Proposed number of units: 26 units Proposed density: 26/0.86 = 30.3 dwelling units per acre Table 4 below summarizes the project’s compliance with standards required for a density bonus. TABLE 4 – CMC SECTION 21.86.090 - DENSITY BONUS HOUSING STANDARDS Standard Analysis Complies? A. Required target dwelling units shall be constructed concurrent with market-rate dwelling units unless both the final decision-making authority of the city and the developer/applicant agree within the density bonus housing agreement to an alternative schedule for development. The four affordable units will be built concurrent with the market rate units. Yes B. Whenever feasible, target dwelling units and density bonus dwelling units should be built on- site (within the boundary of the proposed development) and, whenever reasonably possible, be distributed throughout the project site. The inclusionary units will be built on- site and located within Building E that includes market rate units. In addition, the units will be distributed throughout the building on floors two and three. Yes C. Whenever feasible, target dwelling units should be located on sites that are in proximity to, or will provide access to, employment opportunities, urban services, or major roads or other transportation and commuter rail facilities (i.e., freeways, bus lines) and that are compatible with adjacent land uses. The proposed project is located within 1.2 miles from the bus stop at El Camino Real/La Costa Avenue and within 1.4 miles from the bus stop at Rancho Santa Fe Road/La Costa Avenue, which both currently connect to transit stations. In addition, the project site is located within 1.2 miles of urban services. The proposed project is compatible with existing surrounding multi-family land uses. Yes D. Whenever feasible, target dwelling units should vary in size and number of bedrooms, in response to affordable housing demand priorities of the city. The inclusionary housing includes three one-bedroom units that range in size from 590 to 592 square feet and one two-bedroom unit that is 992 square feet. Yes E. Density bonus projects shall comply with all applicable development standards, except those which may be modified as an incentive or concession, or as otherwise provided for in this chapter. In addition, all units must conform to the requirements of the applicable building and housing codes. The design of the target dwelling units shall be reasonably consistent or compatible with the design of the total project development in terms of appearance, materials and finished quality. With exception to the allowance for increased building height and the stair encroachment, which are a permissible concession and waiver, the project is consistent with all applicable development standards. Further, the design of the target inclusionary units will be the same as the market rate units as they will be incorporated within a building also containing market rate units. Yes F. No building permit shall be issued, nor any development approval granted, for a development which does not meet the requirements of this A density bonus agreement is required to be recorded prior to building permit issuance. The agreement will include Yes SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 6 Standard Analysis Complies? chapter. No target dwelling unit shall be rented or sold except in accordance with this chapter. details as specified pursuant to CMC Section 21.86.130. G. Upon the request of the applicant, the parking ratio (inclusive of handicap and guest parking) for a housing development that conforms to the requirements of Section 21.86.040(A) shall not exceed the ratios specified in Table E or as noted, below. If the applicant does not request the parking ratios specified in this section or the project does not conform to the requirements of Chapter 21.86.040(A), the parking standards specified in Chapter 21.44 of this code shall apply. 1. If a development includes the maximum percentage of low- or very low-income units provided for in Chapter 21.86.040(A) and is located within one-half mile of a major transit stop, as defined in the state Public Resources Code (subdivision (b) of Section 21155), and there is unobstructed access to the major transit stop from the development, then, upon the request of the developer, the city shall not impose a vehicular parking ratio, inclusive of handicapped and guest parking, that exceeds 0.5 spaces per bedroom. For purposes of this subsection, a development shall have unobstructed access to a major transit stop if a resident is able to access the major transit stop without encountering natural or constructed impediments. 2. If a development consists solely of rental units, exclusive of a manager’s unit or units, with an affordable housing cost to lower income families, as provided in state Health and Safety Code (section 50052.5), then, upon the request of the developer, the city shall Table E requires one parking space per unit for units with zero- to one- bedroom, two parking spaces per unit for units with two- to three-bedrooms, and two and a half parking spaces per unit for units with four or more bedrooms. Four, one-bedroom units 4 units x 1 space/unit = 4 spaces Four, two-bedroom units 4 units x 2 spaces = 8 spaces 18, three-bedroom units 18 units x 2 spaces = 36 spaces 8+4+36 = 48 spaces required. 49 spaces provided. 1. N/A 2. N/A Yes SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 7 Standard Analysis Complies? not impose a vehicular parking ratio, inclusive of handicapped and guest parking, that exceeds the following ratios: a. If the development is located within one- half mile of a major transit stop, as defined in state Public Resources Code (subdivision (b) of section 21155), and there is unobstructed access to the major transit stop from the development, the ratio shall not exceed 0.5 spaces per unit. b. If the development is a for-rent housing development for individuals who are 62 years of age or older that complies with state Civil Code (sections 51.2 and 51.3), the ratio shall not exceed 0.5 spaces per unit. The development shall have either paratransit service or unobstructed access, within one-half mile, to fixed bus route service that operates at least eight times per day. c. If the development is a special needs housing development, as defined in state Health and Safety Code (section 51312), the ratio shall not exceed 0.3 spaces per unit. The development shall have either paratransit service or unobstructed access, within one-half mile, to fixed bus route service that operates at least eight times per day. 3. If the total number of parking spaces required for a development is other than a whole number, the number shall be rounded down to the next whole number. 4. For purposes of this section, a housing development may provide “on-site” parking through tandem parking or uncovered parking, but not through on-street parking. 5. The applicant may request parking incentives or concessions beyond those provided in this section, subject to the findings specified in Chapter 21.86.050(A) (2). 6. Notwithstanding subsections G.1 and G.2 of this section, if the city or an independent 3. N/A 4. N/A 5. N/A 6. N/A SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 8 Standard Analysis Complies? consultant has conducted an area-wide or jurisdiction-wide parking study in the last seven years, then the city may impose a higher vehicular parking ratio not to exceed the ratio described in Table E, based upon substantial evidence found in the parking study, that includes, but is not limited to, an analysis of parking availability, differing levels of transit access, walkability access to transit services, the potential for shared parking, the effect of parking requirements on the cost of market-rate and subsidized developments, and the lower rates of car ownership for low- and very low income individuals, including seniors and special needs individuals. The city shall pay the costs of any new study. The city shall make findings, based on a parking study completed in conformity with this paragraph, supporting the need for the higher parking ratio. Incentives/Concessions: Pursuant to CMC Section 21.86.050 (A)(3)(b) of the Density Bonus Ordinance, for a project which designates at least 20 percent of the total units for low-income households, a total of two incentives or concessions shall be granted. An incentive or concession may include any of the following: a. A reduction in site development standards or a modification of zoning code or architectural design requirements (excluding State Building Standards), that results in identifiable, financially sufficient and actual cost reductions. A reduction/modification to standards or requirements may include, but is not limited to, a reduction in minimum lot size, setback requirements, and/or in the ratio of vehicular parking spaces that would otherwise be required. b. Approval of mixed-use zoning in conjunction with the housing development if: (i) commercial, office, industrial or other land uses will reduce the cost of the housing development; and (ii) the commercial, office, industrial, or other land uses are compatible with the housing development and the existing or planned future development in the area where the proposed project will be located. c. Other regulatory incentives or concessions that result in identifiable, financially sufficient and actual cost reductions. d. The city council may, but is not required to, provide direct financial incentives, including the provision of publicly owned land, or the waiver of fees or dedication requirements. SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 9 The applicant is requesting the following incentives/concessions: 1. Allowance for increased building height: The RD-M Zone currently restricts building height to 35 feet. The applicant is requesting the allowance for increased building height as a concession pursuant to the above-noted options. As discussed in the findings in Planning Commission Resolution No. 7358, increased building height is an appropriate concession for the requested density bonus in that it results in cost reductions to enable the provision of housing affordable to the designated income group. 2. Request for excess dwelling units: Since the project proposes to construct more units than permitted at the city’s Growth Management Control Point (GMCP), the additional residential units must be withdrawn from the city’s Excess Dwelling Unit Bank (EDUB). The EDUB is implemented through City Council Policy No. 43. Pursuant to City Council Policy No. 43, an applicant for an allocation of dwelling units shall agree to provide the number of inclusionary units as required pursuant to CMC Section 21.85.050 and shall execute an affordable housing agreement (AHA) prior to building permit issuance pursuant to CMC Section 21.85.140. As discussed in Section C below, the proposal to construct 26 units, including four inclusionary units, is consistent with the inclusionary housing requirement as set forth in City Council Policy No. 43. In approving a request for an allocation of excess dwelling units, the project shall meet the findings identified in City Council Policy No. 43. Specifically, the project location and density shall be found to be compatible with adjacent land uses and the project to be consistent with the General Plan and any other applicable planning document. As discussed in the attached Planning Commission Resolution No. 7358, the proposed project meets these findings. Waivers: In addition to incentives or concessions, CMC Section 21.86.060 also authorizes the waiver or reduction of development standards that would “have the effect of physically precluding the construction of a density bonus housing development at the density or with the incentives or concessions permitted by” CMC Chapter 21.86. There is no limit on the number of waivers or reductions that may be granted, and the grant of a waiver or reduction shall neither increase nor decrease the number of incentives or concessions to which the project is entitled. The project is requesting one waiver to allow the stairs to encroach into the 10-foot rear yard setback four-to-five feet as opposed to the two-foot encroachment permitted per CMC Section 21.46.120(3). Waivers or reductions of development standards shall be granted by the city unless certain findings can be made. In order to deny the requested waivers or reductions, the city would have to make any of the following findings in writing based upon substantial evidence: 1. The standard(s) requested to be waived or reduced will not have the effect of physically precluding the construction of a housing development at the densities or with the incentives or concessions permitted by this chapter; 2. The requested waiver or reduction of development standards would have a specific adverse impact (a significant, quantifiable, direct, and unavoidable impact, based on objective, identified written public health or safety standards, policies, or conditions as they existed on the date the application was deemed complete) upon public health and safety or the physical environment, or on any real property that is listed in the California Register of Historical Resources, and for which there is no feasible method to satisfactorily mitigate or avoid the specific adverse impact; or SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 10 3. The waiver or reduction of development standards would be contrary to state or federal law. Staff has found no substantial evidence that any of the above findings apply in this case. Summary of General Plan compliance: The following Table 5 describes how the proposed project is consistent with the various elements of the Carlsbad General Plan. TABLE 5 – GENERAL PLAN COMPLIANCE ELEMENT USE, CLASSIFICATION, GOAL, OBJECTIVE, OR PROGRAM PROPOSED USES & IMPROVEMENTS COMPLY? Land Use Policy 2-P.8 Do not permit residential development to exceed the applicable Growth Management Control Point (GMCP) density unless the following findings are made: a. The project qualifies for and will receive an allocation of “excess” dwelling units, pursuant to City Council Policy No. 43. b. There have been sufficient residential projects approved at densities below the GMCP so the citywide and quadrant dwelling unit limits will not be exceeded as a result of the proposed project. c. All necessary public facilities required by the Citywide Facilities and Improvements Plan will be constructed, or are guaranteed to be constructed, concurrently with the need for them created by this development and in compliance with adopted city standards. Policy 2-P.9 Incentivize development of lower- income affordable housing by allowing residential development above the GMCP and maximum densities permitted by the General Plan, subject to the findings The proposed 26-unit residential apartment project qualifies for an allocation of excess dwelling units pursuant to City Council Policy No. 43 since the project includes the inclusionary housing units required by CMC Chapters 21.85 and 21.86 and the project is conditioned to execute affordable housing and density bonus housing agreements. There are currently excess dwelling units available in the Southeast Quadrant as a result of residential projects approved at densities below the GMCP. All necessary public facilities required by the Citywide Facilities and Improvements Plan will be constructed, or are guaranteed to be constructed, concurrently with the need for them created by this development and in compliance with adopted city standards. The proposed 26-unit residential apartment project includes four inclusionary units which will be required to be rented to low- income households. The multi- family residential land use is consistent with the adjacent multi- Yes SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 11 specified in 2-P.8, above, and an evaluation of the following: (a) the proposal’s compatibility with adjacent land uses, and (b) the project site’s proximity to a minimum of one of the following: freeway or major street; commercial center; employment opportunities; city park or open space; or commuter rail or transit center. family residential development. The project site is conveniently located two blocks from La Costa Avenue which is a neighborhood connector street providing vehicle and pedestrian access to commercial centers and bus stops within 1.2 miles of the project site. Mobility Policy 3-P.5 Require developers to construct or pay their fair share toward improvements for all travel modes consistent with the Mobility Element, the Growth Management Plan, and specific impacts associated with their development. Goal 3-G.3 Provide inviting streetscapes that encourage walking and promote livable streets. The proposed project has been designed to meet applicable circulation requirements, which include two driveway access points from Viejo Castilla Way. In addition, the applicant will be required to pay traffic impact fees prior to issuance of a building permit that will go towards future road improvements. The proposed project will maintain an existing sidewalk along Viejo Castilla Way which will provide pedestrian access to and from the project. Yes Noise Goal 5-G.2 Ensure that new development is compatible with the noise environment, by continuing to use potential noise exposure as a criterion in land use planning. The project consists of 26 residential apartments located in five buildings. A noise study by Rincon Consultants, Inc, dated November 2018, was provided. The apartment project does not have any required exterior private recreation areas and therefore is not subject to the maximum 60 dB(a) CNEL noise level. Furthermore, existing ambient noise levels are below the maximum 60 dB(a) CNEL noise level at 56.7 dB(a) CNEL. Given the exterior noise levels and modern building construction that meets or exceeds the 2019 California Green Building Code requirements, the project will experience interior noise levels below the required 45 dB(a) CNEL interior noise level. Yes SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 12 Public Safety Goal 6-G.1 Minimize injury, loss of life, and damage to property resulting from fire, flood, hazardous material release, or seismic disasters. Policy 6-P.6 Enforce the requirements of Titles 18, 20, and 21 pertaining to drainage and flood control when reviewing applications for building permits and subdivisions. Policy 6-P.34 Enforce the Uniform Building and Fire codes, adopted by the city, to provide fire protection standards for all existing and proposed structures. Policy 6-P.39 Ensure all new development complies with all applicable regulations regarding the provision of public utilities and facilities. The proposed structural improvements are required to be designed in conformance with all seismic design standards. In addition, the proposed project is consistent with all of the applicable fire safety requirements. Further, the project has been conditioned to develop and implement a program of “best management practices” for the elimination and reduction of pollutants which enter into and/or are transported within storm drainage facilities. Yes Housing Goal 10-G.3 Sufficient new, affordable housing opportunities in all quadrants of the city to meet the needs of current lower and moderate income households and those with special needs, and a fair share proportion of future lower and moderate income households. Goal 10-P.15 Pursuant to the Inclusionary Housing Ordinance, require affordability for lower income households of a minimum of 15 percent of all residential ownership and qualifying rental projects. For projects that are required to include 10 or more units affordable to lower income households, at least 10 percent of the lower income units should have three or more bedrooms (lower income senior housing projects exempt). The proposed project includes four inclusionary units (20 percent) which will be required to be rented to low-income households. The provision for inclusionary housing will contribute toward achieving the city’s Regional Housing Needs. The project has been conditioned accordingly to require the approval of an Affordable Housing Agreement prior to building permit issuance. Yes SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 13 B. Multiple-Family Residential (RD-M) Zone (CMC Chapter 21.24) The proposed project is required to comply with all applicable use and development standards of the Carlsbad Municipal Code (CMC) including the Residential Density – Multiple (RD-M) Zone (CMC Chapter 21.24). The 26-unit residential apartment project meets or exceeds the requirements of the RD-M Zone, except building height and stair encroachment into the rear setback, as outlined in Table 6 below. TABLE 6 – RD-M ZONE COMPLIANCE R-3 Standards Required Proposed Comply Setbacks Front (Viejo Castilla Way): 20’; or 15’ provided carport or garage openings do not face onto the front yard; or 10’ provided carport or garage openings do not face onto the front yard and the remaining front yard is landscaped. Interior Side: 5’ Front (Viejo Castilla Way): 10’ with landscaping: Interior Side: 5’ Yes Rear: 10’ Rear Encroachments: Stairs may encroach 2 feet into setback area. Rear: 10’ to building Rear Encroachments: Stairs encroach four to five feet into 10’ setback area.* Yes * * Density Bonus Waiver for stair encroachment. Lot Coverage 60% 53.4% Yes Policy 10-P.18 Adhere to City Council Policy Statement 43 when considering allo- cation of “excess dwelling units” for the purpose of allowing development to exceed the Growth Management Control Point (GMCP) density, as discussed in Section 10.3 (Resources Available). With limited exceptions, the allocation of excess dwelling units will require provision of housing affordable to lower income households. In approving a request for an allocation of excess dwelling units, the project shall meet the findings identified in City Council Policy No. 43. Specifically, the project location and density shall be found to be compatible with adjacent land uses and the project is consistent with the General Plan and any other applicable planning document. As discussed in the attached Planning Commission Resolution No. 7358, the proposed project meets these findings. SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 14 R-3 Standards Required Proposed Comply Building Height 35’ Building A 33’-11” with projections to 38’-7.5” Building B 33’-2”’ with projections to 38’-3” Building C* 48’-2” with projections to 50’-11” Building D* 47-11” with projections to 50’-8.5” Building E 31’-11” with projections to 36’-11” Yes* * Density Bonus Incentive for height. As summarized in Table 7 below, the proposed residential apartment project is consistent with the parking requirements pursuant to the Density Bonus Ordinance. TABLE 7 – PARKING ANALYSIS USE Ratio REQUIRED PROPOSED COMPLY? Residential Apartments developed pursuant to the Density Bonus Ordinance. One bedroom: 1 space/unit Two bedroom: 2 spaces/unit Three bedroom: 2 spaces/unit One bedroom: 4 4 units = 4 spaces Two bedroom: 4 4 units = 8 spaces Three bedroom: 18 18 units = 36 spaces 4 covered parking spaces. 8 covered parking spaces. 36 garaged spaces. Additional Parking: 1 covered parking spaces. Yes TOTAL REQUIRED: 48 PROPOSED: 49 Yes C. Qualified Development Overlay Zone (CMC Chapter 21.06) Pursuant to Section 21.53.120 of the CMC, a Site Development Plan (SDP) is required to be processed for this 26-unit apartment project pursuant to CMC Chapter 21.06, the Qualified Development Overlay Zone. As demonstrated in Table 8 below, all of the required SDP findings can be made. TABLE 8 – SITE DEVELOPMENT PLAN FINDINGS FINDING PROJECT CONSISTENCY That the proposed development or use is consistent with the General Plan and any applicable master plan or specific plan, complies with all applicable provisions of Chapter 21.06 of the Carlsbad Municipal Code, and all other applicable provisions of this code. The project is consistent with the various elements and objectives of the General Plan as discussed in Section “A” of the project staff report. The various goals and objectives of the General Plan will be implemented as the proposed project is consistent with the General Plan, which allows for a mixture of residential uses, including multiple-family residential, within the R-23 Residential Land Use designation. As discussed in Section “A” above, although the project’s density of 30.3 dwelling units per acre is above the maximum R-23 Residential density of 23 du/ac, the 26-unit residential apartment project can be found SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 15 consistent with the General Plan Land Use Policies as discussed in Section “A”, Table 5 above. FINDING PROJECT CONSISTENCY That the requested development or use is properly related to the site, surroundings and environmental settings, will not be detrimental to existing development or uses or to development or uses specifically permitted in the area in which the proposed development or use is to be located, and will not adversely impact the site, surroundings or traffic circulation. The proposed multiple-family residential use will not be detrimental to existing uses or to uses specifically permitted in the area in which the use is located in that multiple-family residential is a permitted use within the Residential Density – Multiple (RD-M) Zone and is compatible with the other multiple- family residential uses surrounding the project site. The residential apartment project will not adversely impact the site, surroundings, or traffic circulation in that the existing surrounding streets have adequate capacity to accommodate the 156 Average Daily Trips (ADT) generated by the project. With exception to the allowance for increased building height and the rear stair encroachment as discussed in Section “A” above, the project complies with all minimum development standards of the Carlsbad Municipal Code, including but not limited to the RD- M Zone, and the project is adequately parked on-site and does not result in any environmental impacts. That the site for the intended development or use is adequate in size and shape to accommodate the use The subject site is adequate in size and shape to accommodate the proposed 23-unit residential apartment building in that with exception to the allowance for increased building height and rear stair encroachment as discussed in Section “A” above, the residential apartment project complies with all remaining development standards of the Residential Density – Multiple (RD-M) Zone and all other applicable sections of the Zoning Ordinance, as demonstrated in Table 6 above. That all yards, setbacks, walls, fences, landscaping, and other features necessary to adjust the requested development or use to existing or permitted future development or use in the neighborhood will be provided and maintained With exception to the allowance for increased building height and rear stair encroachment as discussed in Section “A” above, the project complies with all remaining development standards (i.e. front, side and rear setbacks, lot coverage, parking) of the Residential Density – Multiple (RD-M) Zone, as demonstrated in Table 6 above. Landscaping along the outer edges of the property, including the areas along Viejo Castilla Way, will be provided consistent with the requirements of the city’s Landscape Manual. That the street systems serving the proposed development or use is adequate to properly handle all traffic generated by the proposed use The project will take access off Viejo Castilla Way with vehicles traveling to and from the project on Viejo Castilla Way as well. Viejo Castilla Way is identified as a local street, designed to adequately handle the 156 Average Daily Trips generated by the 26-unit residential apartment project. D. Hillside Development Ordinance (CMC Chapter 21.95) The project is subject to the Hillside Development Regulations because the site contains slopes over 15% and slope elevation differences greater than 15 feet. The steeper slopes traverse the site from northwest to southeast. The steep slope area is roughly 653 square feet in area with a slope gradient of 40% or greater. SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 16 The development complies with the Hillside Development Ordinance and Hillside Development Guidelines. The proposed project is consistent with the Land Use and Open Space/Conservation Elements of the General Plan since the site has been previously graded, there exist no natural hillsides, and the project site has limited value as habitat for endangered, rare or threatened species. The project design minimizes the amount of grading to an acceptable quantity of 5,653 cubic yards per acre, will incorporate an aesthetically pleasing design with landscaping, and retaining walls will be developed primarily into the slope as opposed to on top of the slope to minimize the visual impacts on the adjacent properties and public roadways. The existing hillside is manufactured and accordingly, there will be no impacts to natural resource areas, wildlife habitats or native vegetation areas that have not already been analyzed, anticipated and authorized by the City's Habitat Management Plan (HMP). Finally, there will be no impact on lagoons or riparian ecosystems in that the project has been conditioned to submit an erosion control plan consistent with the NPDES permit requirements as required by the Regional Water Quality Control Board and the City of Carlsbad. E. Inclusionary Housing (CMC Chapters 21.85) The Inclusionary Housing regulations, specifically CMC Chapter 21.85, shall apply to any new construction of rental units where the developer receives offsets or any incentives of the type specified in the density bonus law pursuant to the provisions of CMC Chapter 21.86 and the developer agrees by contract to limit rents for below market-rate rental units. Pursuant to CMC Section 21.85.030, not less than 15 percent of the total units approved shall be constructed and restricted both as to occupancy and affordability to lower-income households. To satisfy this requirement, the applicant proposes to designate four units as inclusionary units although only three units are required per CMC Section 21.85. The four units will be affordable to households earning more than fifty percent but not exceeding eighty percent of the San Diego Area Median Income (AMI) as determined annually by the U.S. Department of Housing and Urban Development. The city’s Housing Policy Team recommended approval of the request on November 25, 2019. As required by CMC Chapters 21.85 and 21.86, the project has been conditioned to require the approval of an Affordable Housing Agreement and Density Bonus Housing Agreement, respectively, prior to building permit issuance. F. Growth Management (CMC Chapter 21.90) The proposed project is located within Local Facilities Management Zone 6 in the Southeast Quadrant of the city. The impacts on public facilities created by the project, and its compliance with the adopted performance standards, are summarized in Table 9 below. SDP 2018-0022 / HDP 2018-0006 (DEV2017-0225) – RESORT VIEW APARTMENTS February 5, 2020 Page 17 TABLE 9 – GROWTH MANAGEMENT COMPLIANCE STANDARD IMPACTS COMPLIANCE City Administration 91.96 sq. ft. Yes Library 49.05 sq. ft. Yes Waste Water Treatment 26 EDU Yes Parks 0.18 acres Yes Drainage 4.4 CFS Yes Circulation 156 ADTs Yes Fire Station 6 Yes Open Space n/a n/a Schools E: 2.83, M: 2.13, H: 3.48 Yes Sewer Collection System 5,720 GPD Yes Water 6,500 GPD Yes The project proposes 26 dwelling units and the unit yield at the GMCP of the property is 16 dwelling units. Therefore, a total of ten (10) dwelling units are proposed to be deducted from the City’s Excess Dwelling Unit Bank. Pursuant to Planning Commission Resolution No. 7358, the allocation from the EDUB can be supported since 327 units are available for allocation in the Southeast Quadrant according to the city’s Quadrant Dwelling Unit Report dated November 30, 2019. IV. ENVIRONMENTAL REVIEW The City Planner has determined that the project belongs to a class of projects that the State Secretary for Resources has found do not have a significant impact on the environment, and it is therefore categorically exempt from the requirement for the preparation of environmental documents pursuant to Section 15332 (In-Fill Development Projects) Class 32 Categorical Exemption of the State CEQA Guidelines. The project is consistent with the General Plan as well as with the Zoning Ordinance. The project site is within the city limits, is less than five acres in size, and is surrounded by urban uses. There is no evidence that the site has value as habitat for endangered, rare, or threatened species. Approval of the project will not result in significant effects relating to traffic, noise, air quality, or water quality, and the site can be adequately served by all required utilities and public services. In making this determination, the City Planner has found that the exceptions listed in Section 15300.2 of the state CEQA Guidelines do not apply to this project in that there are no unusual circumstances that apply to this project site. A Notice of Exemption will be filed by the City Planner upon final project approval. The 26-unit apartment project is consistent with the Climate Action Plan (CAP) because the project will be required to comply with all applicable CAP ordinances and state law requirements in effect at the time of application for grading and building permits. ATTACHMENTS: 1. Planning Commission Resolution No. 7358 2. Location Map 3. Disclosure Statement 4. Enhanced Stakeholder Outreach Report 5. Reduced Exhibits 6. Full Size Exhibits “A” – “OO” dated February 5, 2020 NAVARRA DR LA COS T A A V VIEJO CASTILLA WYPIRINEOS WY LA COR U N A P L SDP 2018-0022 / HDP2018-0006 (DEV2017-0225)RESORT VIEW APARTMENTS SITE MAP J SITE E L C AMINO RE A LLA COSTA AV A L G A R DCARLSBAD B L POINSETT I A L N ATTACHMENT 2 ATTACHMENT 3 ATTACHMENT 4 PROJECT LOCATIONTO 5 FWYSAN MARCOS CREEKRANCHO SANTA FE RDGIBRALTARROMERIA LEVANTE STLA COSTA AVENAVARRA DRVIEJO CASTILLA WAYEL CAMINO REALNAPN(S): OCCUPANCY GROUP:TYPE OF CONSTRUCTION: ZONING: GENERAL ZONING:2161701500, -1400R2, TYPE VA OVER TYPE IRD-MR-23LEGAL DESCRIPTION:PROPOSED LOT COVERAGE:STORIES: DWELLING UNITS:DWELLING UNITS PER ACRE:ACCESSIBLE UNITS:AFFORDABLE UNITS:19,269 SF // 57.2%4 (1 PARKING + 3 LIVING)26 TOTAL; 6 MULTI-STORY TOWNHOUSE APARTMENTS, 20 APARTMENTS 32.66 DU/AC223 -E1,E2,E6SITE DATA:LOT SIZE: LOT AREA:DEVELOPABLE AREA SF:0.858 ACRES37,375SF37,375SFADDITIONAL INFORMATION:TOTAL BUILDING COVERAGE19,269 SF / 33,375 SF LOT COVERAGE DATA:19,269SF57.7%THE LAND REFERRED TO HEREIN BELOW IS SITUATED IN THE CITY OF CARLSBAD, IN THE COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, AND IS DESCRIBED AS FOLLOWS:LOTS 35 AND 36 OF LA COSTA SOUTH UNIT NO. 1, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 6117, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, JUNE 3, 1968.CUT:FILL:EXPORT:REMEDIAL:REPLACED IMPERVIOUS AREA:PROPOSED IMPERVIOUS AREA:GRADING INFORMATION:4,000CY500CY3,500CY3,500CY0SF31,810SFBUILDING A:BUILDING B: BUILDING C:BUILDING D:BUILDING E:BUILDING HEIGHT INFORMATION: FROM FINISH GRADE33'-11" with projections to 38'-7 1/2"33'-2"with projections to 38'-3"48'-2"with projections to 50'-11"47'-11'with projections to 50'-8 1/2"31-11" with projections to 36'-11"2016 CALIFORNIA RESIDENTIAL CODE2016 CALIFORNIA MECHANICAL CODE2016 CALIFORNIA PLUMBING CODE2016 CALIFORNIA ELECTRICAL CODE2016 CALIFORNIA ENERGY CODE2016 CALIFORNIA GREEN BUILDING CODE2016 CALIFORNIA FIRE CODEOWNER:RAM SETYABNR DEVELOPMENT 23800 VIA DEL RIO, YORBA LINDA, CA 92887ARCHITECT:MICHAEL FOXFOXLIN ARCHITECTS392 CAMINO DE ESTRELLASAN CLEMENTE CA 92672(949) 325-3001 TEL(949) 203-3339 FAXINFO@FOXLIN.COMLANDSCAPE ARCHITECT:PAT MURPHYSMP ENVIRON. DESIGNSUITE 20034197 PACIFIC COAST HWY.DANA POINT, CA 92629(949)443.1446INFO@SMPINC.NETSTRUCTURAL ENGINEER:KURT FISCHERKURT FISCHER STRUCTRUAL ENGINEERS17547 VENTURA BLVD. SUITE 302ENCINO, CA, 91316TELEPHONE: (818) 874-1445EMAIL: INFO@KFSENG.COMSOILS:RYAN BOHMERGEOSOILS5741 PALMER WAYCARLSBAD, CALIFORNIA 92010(760) 438-3155CIVIL / SURVEY:MICHAEL BENESH MLB ENGINEERING 404 S. LIVE OAK PARK ROADFALLBROOK, CA 92028760 731-6603MECHANICAL, ELECTRICAL, AND PLUMBING:ENVIRONMENTAL REPORTS:RINCON180 NORTH ASHWOOD AVE.VENTURA CA, 93003(805) 644-4455DEVELOPMENT:JOHN ALLENSTREAMLINE DEVELOPMENT GROUPPO BOX 99417 SAN DIEGO, CA 92169 (805) 889-0447 JOHN@STREAMLINEDEVEL-OPMENTGROUP.COMTHE PROJECT SCOPE INCLUDES 26 UNITS; 6 TOWNHOUSE STYLE WITH SEPARATE PARKING, 18 SINGLE STORY APARTMENTS, WITH SHARED AND PRIVATE GARAGES. MERGE TWO LOTS.SETBACKS FRONT YARD(WITH APPROVAL): INTERIOR SIDE YARD: REAR YARD: MAX LOT COVERAGE HEIGHT LIMIT10 FT5 FT10 FT60%35 FT REQUIRED:TWO PER 3 BEDROOM @ 18 UNITS TWO PER 2 BEDROOM @ 4 UNITONE PER 1 BEDROOM @ 4 UNITS TOTAL COMPACT -45% MAX COVERED / GARAGE NON-COVEREDADA VAN ACCESSIBLE368448NONE 24231 TOTALPROVIDED:GARAGED (2PER @ 14 UNITS): COVERED:ADA VAN PARKING:TOTAL:3612149MIN. AND MAX. LIMITS:USE: RESIDENTIALCATAGORY:OVER 20 UNITSIMPACT RATE:6 PER DWELLING UNITIMPACT CALC.:156 = 6 * 26duPEAK WEEKDAY:170.0 = 156(1.09)TRASH:WASTE MANAGEMENTWATER DISTRICT:CARLSBAD MUNICIPAL FIRE DISTRICT:6SEWER DISTRICT:LEUCADIA WASTEWATER DISTRICTSCHOOL DISTRICT:ENCINITAS UNIFIED SCHOOL DISTRICT1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE(F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITHCONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FORMEANS AND METHODS.DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/14/202011:00:05 AM4PLANNINGCOMMISSIONREV1/14/2020 11:00:05 AMBNR DEVELOPMENTTITLEG-001RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENTG-001 // TITLE // ISSUED: xVICINITY MAPPROJECT DATAGOVERNING CODESPROJECT DIRECTORYSHEET LIST#SHEET NAMEREVISIONGENERALG-001 TITLE4G-002 ADDITIONAL INFORMATION4G-003 BUILDING AREAS4G-004 SLOPE ANALYSIS4ARCHITECTURALA-101 SITE PLAN4A-102 PARKING DESIGN4A-110 FLOOR PLAN TYPE A4A-130 FLOOR PLAN TYPE B4A-150 FLOOR PLAN TYPE C, D & E4A-160 SITE ROOF PLAN4A-201 SITE ELEVATIONS4A-202 SITE ELEVATIONS4A-211 ELEVATIONS - BUILDING A4A-212 ELEVATIONS - BUILDING B4A-213 ELEVATIONS - BUILDING C & D4A-214 ELEVATIONS - BUILDING E4A-301 SECTIONS4A-302 SECTIONS4A-303 SECTIONS4A-304 SECTIONS4A-305 CONTEXT SECTIONS4A-900 3D RENDERINGS4A-901 3D RENDERINGS4A-902 MATERIALS BOARD4CIVILC-01 PRELIMINARY GRADING4C-02 DETAILS AND SECTIONS4C-03 DETAILS AND SECTIONS4LANDSCAPINGL-01 TITLE SHEET4L-02 CONSTRCUTION LAYOUT PLAN4L-03 CONSTRCUTION LAYOUT PLAN4L-04 CONSTRCUTION DETAILS4L-05 CONSTRCUTION SPECIFICATIONS 4L-06 MAINTENANCE RESPONSIBILITY PLAN 4L-07 TREE PLANTING LAYOUT4L-08 TREE PLANTING LAYOUT4L-09 SHRUB PLANTING LAYOUT4L-10 SHRUB PLANTING LAYOUT4L-11 PLANTING DETAILS4L-12 PLANTING NOTES4L-13 IRRIGATION TITLE SHEET4L-14 IRRIGATION HYDROZONE PLAN4VIEJO CASTILLA WAY, CARLSBAD CA 92009RESORT VIEW APARTMENTSSCOPE OF WORKZONING INFORMATIONPARKING DATATRAFFIC IMPACTAPPLICATIONS SUBMITTEDSITE DEVELOPMENT PLANSERVICES DIRECTORYAPN #s: 216-170-1400, 216-170-1500REVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020ATTACHMENT 5 & And<ANGLE@ ATCENTERLINE# NUMBERº DEGREE(E) EXISTINGABV ABOVEAB ANCHOR BOLTACFL ACCESS FLOORACOUS ACOUSTICALACT ACOUSTICAL CEILING TILEAD AREA DRAINADD ADDENDUMADDL ADDITIONALADJ ADJUSTABLEADMIN ADMINISTRATIONAFF ABOVE FINISH FLOORAHU AIR HANDLING UNIT ALT ALTERNATEALUM ALUMINUMAMEND AMENDMENTANUN ANUNCIATORAP ACCESS PANELAPC ARCHITECTURAL PRECAST CONCRETEAPROX APPROXIMATEARCH ARCHITECTURAL/ARCHITECTAUTO AUTOMATICAWT ACOUSTICAL WALL TREATMENTBA BUILDING ACCESSORYBD BOARDBFE BOTTOM FOOTING ELEVATIONBG BUMPER GUARDBIT BITUMINOUSBKT BRACKETBLDG BUILDINGBLKG BLOCKINGBLW BELOWBM BEAMBO BY OWNERBOF BY OWNER FUTUREBOT BOTTOMBR BEDROOMBRG BEARINGBSMT BASEMENTBTWN BETWEENBULL BULLETINBUR BUILT-UP ROOFINGC CHANNELC DISP CUP DISPENSERCAB CABINETCANTL CANTILEVERCAP CAPACITYCAT CATEGORYCG CORNER GUARDCH COAT HOOKCJT CONTROL JOINTCI CONSTRUCTION ISSUEDCLG CEILINGCLR CLEARCM CONSTRUCTION MANAGERCO CASED OPENINGCOL COLUMNCOMB COMBINATION/-EDCONC CONCRETECONF CONFERENCECONN CONNECT/-ED/-IONCONST CONSTRUCTIONCONT CONTINUE/OUSCONTR CONTRACT/ORCORR CORRIDORCPT CARPETCT CERAMIC TILECTR CENTERCTSK COUNTERSUNKCUH CABINET UNIT HEATERCW CURTAIN WALLCW COLD WATERCYL CYLINDERD DEPTH OR DEEPDEMO DEMOLITIONDPR DEPRESSIONDEPT DEPARTMENTDET DETAILDF DRINKING FOUNTAINDIA DIAMETERDIAG DIAGONALDIFF DIFFUSERDIM DIMENSIONDISP DISPENSERDIST DISTRIBUTIONDIV DIVISIONDN DOWND.O. DOOR OPENINGGA GAUGEGAL GALLONSGALV GALVANIZEDGB GRADE BEAMGC GENERAL CONTRACTORGEN GENERATORGEN GENERALGL GLASSGWA GENERAL WORK AREAGR GRADEGYB GYPSUM BOARDGYPSHTG GYPSUM SHEATHINGH HEIGHT/HIGHHB HOSE BIBHD HAND DRYERHDCP HANDICAPHDR HEADERHDW HARDWAREHM HOLLOW METALHORIZ HORIZONTALHPT HIGH POINTHR HANDRAILHT HEIGHTHTR HEATERHVAC HEATING, VENTILATING, AIR CONDITIONINGHW HOT WATERHWD HARDWOODIC INTERCOMID INSIDE DIAMETERIN INCHINSUL INSULATIONINT INTERIORISO ISOLATIONJAN JANITORJB JUNCTION BOXJST JOISTJT JOINTKO KNOCK OUTLAV LAVATORYLB POUNDLBS POUNDS (WIEGHT)LCD LINEAR CEILING DIFFUSERLF LINE FIGUREDLIN LINEARLKR LOCKERLMC LINEAR METAL CEILINGLOC LOCATION OR LOCATELPT LOW POINTLT LIGHTLTG LIGHTINGLVR LOUVERLWC LINEAR WOOD CEILINGM MIDDLEMAN MANUALMATL MATERIALMAX MAXIMUMMBD MARKER BOARDMC MEDICINE CABINETMECH MECHANICALMEMB MEMBRANEMEZZ MEZZANINEMFR MANUFACTURERMIN MINIMUMMIR MIRRORMISC MISCELLANEOUSMO MASONRY OPENINGMONO MONOLITHICMTL METALMPC METAL PAN CEILINGMPU MULTI-PURPOSE UNITMTD MOUNTEDMTR MOTORMULL MULLIONNA NOT APPLICABLENIC NOT IN CONTRACTNO NUMBERNOM NOMINALNRC NOISE REDUCTION COEFFICIENTNT NOTENTS NOT TO SCALEOC ON CENTEROD OUTSIDE DIAMETEROFF OFFICEOH OVERHEADOP OPERABLE PARTITIONOPER OPERATOROPNG OPENINGOPP OPPOSITEORD OVERFLOW ROOF DRAINPART PARTITIONPB PUSH BUTTONPC PRECAST CONCRETEPL PROPERTY LINEPLT PLATEPLAM PLASTIC LAMINATEPLBG PLUMBINGPLS PLASTERPLW PLYWOODPNL PANELPR PAIRPRELIM PRELIMINARYPRESS PRESSUREPRIM PRIMARYPROJ PROJECTIONPT PAINTPVC POLYVINYL CHLORIDEQT QUARRY TILER RISERRA RETURN AIRRAD RADIATIONRB RESILIENT BASERD ROOF DRAINRE RELOCATE EXISTINGREC RECESSEDREF REFERENCEREFR REFRIGERATORREG REGISTERREINF REINFORCE/-ED/-INGREM REMOVEREQD REQUIREDRET RETAININGREV REVERSEREV REVISERF RESILIENT FLOORRH ROOF HATCHRM ROOMRO ROUGH OPENINGRS ROUGH SLABS SINK/SUPPLY FANSCHED SCHEDULESD SHOWER DRAINSDM SMOKE DAMPERSDISP SOAP DISPENSERSECT SECTIONSECY SECRETARYSF SQUARE FOOTSFG STORE FRONT GLASSSH SHOWERSHD SHOWER HEADSHT SHEETSHTG SHEATHINGSIM SIMILARSL SEALERSLNT SEALANTSLV SLEEVESM SURFACE MOUNTEDSOG SLAB ON GRADESP STANDPIPESPEC SPECIFICATIONSSPR SINGLE PLY ROOFSQ SQUARESQ YD SQUARE YARDSS SERVICE SINKSST STAINLESS STEELST STREETSTI STONE TILESTC SOUND TRANSMISSIONSTD STANDARDSTL STEELSTN STONESTNL STONE LEDGESTOR STORAGESTR STRUCTURALSTS STEEL STRUCTURESUPV SUPERVISORSUSP SUSPENDEDSW STEEL WINDOWSSW SWITCHSWD SOFTWOODSYM SYMMETRICALT TOPTAN TANGENTTBD TACKBOARDTCAB TOWEL CABINETTDISP TISSUE DISPENSERTDR TRENCH DRAINTEL TELEPHONETEMP TEMPERATURETER TERRAZZOTG TONGUE & GROOVETHRES THRESHOLDTPH TOILET PAPER HOLDERTR TREADTRANSF TRANSFORMERTS TUBE SECTIONTV TELEVISIONTYP TYPICALU URINALUC UNDERCUTUFD UNDER FLOOR DUCTUG UNDERGROUNDUH UNIT HEATERUNFIN UNFINISHEDUNO UNLESS NOTED OTHERWISEUS UTILITY SHELFUTIL UTILITYVC VALVE CABINETVENT VENTILATIONVERT VERTICALVEST VESTIBULEVTR VENT THROUGH ROOFW WIDE FLANGEW/ WITHW/O WITHOUTWC WATER CLOSETWC WALL COVERINGWD WOODWDW WINDOWWG WALL GUARDWH WALL HYDRANTWHCH WHEELCHAIRWHTR WATER HEATERWPR WATERPROOFWR WASTE RECEPTACLEWS WEATHERSTRIPWSCT WAINSCOTWT WINDOW TREATMENTWT WEIGHTWW WOOD WINDOWWWF WELDED WIRE FABRICDOU DOUBLEDP DEMOUNTABLE PARTITIONDR DOORDS DOWNSPOUTDW DUMBWAITERDWG DRAWINGDWLS DOWELSEA EACHEC ELECTRIC CABINETEF EXHAUST FANEIFS EXTERIOR INSULATION AND FINISH SYSTEMEJT EXPANSION JOINTEL ELEVATIONELEC ELECTRICALELEV ELEVATOREMERG EMERGENCYENCL ENCLOSUREENTR ENTRANCEEO ELECTRICAL OUTLETEQ EQUALEQUIP EQUIPMENTES END SECTIONEWC ELECTRIC WATER COOLEREXC EXCAVATE/-ED/-IONCL101.AWindow SymbolInstance No.Door Tag00Building Gridlines1 AA1011SIM8'-0"NSectionSection No.Sheet No.North ArrowRoom No.Instance No.Room No.Detail CalloutExterior ElevationInterior ElevationCeiling HeightRoom LabelMatchlineRevision Cloud 1Dimension String1/4"1/2"3/4"Elev No.Sheet No.Detail No.Sheet No.Area ReferencedCeiling HeightFloor LevelA1011SIMDetail No. & Sheet No.Revision No.(Cloud aroundRevision optional)(Shaded portion faces side considered)Elev No.Sheet No.A1.121Project northTrue North1A101SIM1A101NameElevationAbsoluteRelative0"1"1"To StructureTo FinishWall Finish TypeWall Tag2x4 Wall2x6 WallRoof Finish TypeRoof TagRoof InstanceFloor TagAFloor Type MarkSimilar or Typical (TYP.)1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:40:04AM4PLANNINGCOMMISSIONREV1/13/2020 8:40:04 AMBNR DEVELOPMENTADDITIONALINFORMATION G-002RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT G-002 // ADDITIONAL INFORMATION // ISSUED: xABBREVIATIONSSYMBOLSREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 4511 SFC4575 SFD4329 SFE3084 SFA3086 SFB223 SFTRAREA 0 - 25% SLOPE.754 acAREA 25% - 40% SLOPE .084 ac50% USABLE.042 acAREA OVER 40%.015 acDEVELOPABLE AREA .773 acresIN FT33,671 ft²1827 SFSITE664 SFSITE445 SFA1450 SFA2425 SFA3423 SFB1452 SFB2450 SFB3426 SFDG3419 SFDG5407 SFDG6413 SFDG4426 SFDG2434 SFDG1375 SFCG3369 SFCG5406 SFCG6412 SFCG4406 SFCG2369 SFCG1473 SFAG1479 SFAG2441 SFAG3448 SFBG1486 SFBG2485 SFBG3677 SFDG21520 SFD1903 SFA1936 SFA2992 SFE1590 SFE2592 SFE3790 SFA3783 SFB1928 SFB2896 SFB31504 SFD21519 SFC11522 SFC21054 SFE488 SFE1D1533 SFD3859 SFA11627 SFA2RedundantAreaA3748 SFB1850 SFB2846 SFB31515 SFD41516 SFC31531 SFC4991 SFE5591 SFE6592 SFE71054 SFE886 SFE5D1533 SFD51515 SFD61531 SFC61509 SFC5247 SFA1D246 SFA2D224 SFA3D218 SFB1D239 SFB2D243 SFB3D1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/14/202010:59:43 AM4PLANNINGCOMMISSIONREV1/14/2020 10:59:43 AMBNR DEVELOPMENTBUILDING AREASG-003RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENTG-003 // BUILDING AREAS // ISSUED: x1" = 30'-0"1LOT COVERAGE2Site - LEVEL 023Site - LEVEL 03AREA SCHEDULE (GROSS)AREA / BUILDING AREA TYPEAREA % of Devleopable AreaExterior AreaNAN/A0 SF 0.0%ROAD ACIRCULATION0 SF 0.0%ROAD BCIRCULATION0 SF 0.0%SITEOPEN SPACE2491 SF 7.4%Exterior Area2491 SF 7.4%Gross Building AreaABUILDING3084 SF 9.2%BBUILDING3086 SF 9.2%CBUILDING4511 SF 13.4%DBUILDING4575 SF 13.6%EBUILDING4329 SF 12.9%TRBUILDING223 SF 0.7%Gross Building Area19809 SF 58.8%4Site - LEVEL 045Site - LEVEL 05UNIT SCHEDULE (DETAIL)UNITUNITTYPEAREA BEDS BATHSOPENSPACEPARKINGREQ.AFFORDABLE(LOW)ADAADAPTABLEAA1 A 2207 SF 3 3 60 SF 2 No YesA2 A 3012 SF 3 3 60 SF 2 No NoA3 A 1215 SF 3 3 60 SF 2 No No6435 SF 9 9 180 SF 6BB1 A 1954 SF 3 3 60 SF 2 No YesB2 A 2230 SF 3 3 60 SF 2 No NoB3 A 2192 SF 3 3 60 SF 2 No Yes6376 SF 9 9 180 SF 6CC1 B 1519 SF 3 3 60 SF 2 No YesC2 B 1522 SF 3 3 60 SF 2 No YesC3 B 1516 SF 3 3 60 SF 2 No YesC4 B 1531 SF 3 3 60 SF 2 No YesC5 B 1509 SF 3 3 60 SF 2 No YesC6 B 1531 SF 3 3 60 SF 2 No Yes9128 SF 18 18 360 SF 12DD1 B 1520 SF 3 3 60 SF 2 No YesD2 B 1504 SF 3 3 60 SF 2 No YesD3 B 1533 SF 3 3 60 SF 2 No YesD4 B 1515 SF 3 3 60 SF 2 No YesD5 B 1533 SF 3 3 60 SF 2 No YesD6 B 1515 SF 3 3 60 SF 2 No Yes9120 SF 18 18 360 SF 12EE1 C 992 SF 2 2 0 SF 2 Yes YesE2 D 590 SF 1 1 0 SF 1 Yes YesE3 D 592 SF 1 1 0 SF 1 Yes YesE4 E 1054 SF 2 2 0 SF 1 No YesE5 C 991 SF 2 2 0 SF 2 No YesE6 D 591 SF 1 1 0 SF 1 Yes YesE7 D 592 SF 1 1 0 SF 1 No YesE8 E 1054 SF 2 2 0 SF 1 No Yes6457 SF 12 12 0 SF 10GRAND TOTAL:3837515 SF 66 66 1080 SF 46*NOTE: THE "D" ON THE END OF UNIT NUMBER REPRESENTS A DECK THAT ISN'T PART OF UNIT AREA CALCULATION, BUT IS PART OF EGRESS CALCULATIONEGRESS LOAD CALCULATIONUNITUNITTYPEAREA BEDS BATHSOCCUPANCYTYPEOCCUPANTLOAD FACTOROCCUPANCYLOADAA1 A 2207 SF 3 3 R3 200 11A1D A 247 SF 0 0 N/A 0 0A2 A 3012 SF 3 3 R3 200 15A2D A 246 SF 0 0 N/A 0 0A3 A 1215 SF 3 3 R3 200 6A3D A 224 SF 0 0 N/A 0 07152 SF 9 9 32BB1 A 1954 SF 3 3 R3 200 10B1D A 218 SF 0 0 N/A 0 0B2 A 2230 SF 3 3 R3 200 11B2D A 239 SF 0 0 N/A 0 0B3 A 2192 SF 3 3 R3 200 11B3D A 243 SF 0 0 N/A 0 07077 SF 9 9 32CC1 B 1519 SF 3 3 R3 200 8C2 B 1522 SF 3 3 R3 200 8C3 B 1516 SF 3 3 R3 200 8C4 B 1531 SF 3 3 R3 200 8C5 B 1509 SF 3 3 R3 200 8C6 B 1531 SF 3 3 R3 200 89128 SF 18 18 46DD1 B 1520 SF 3 3 R3 200 8D2 B 1504 SF 3 3 R3 200 8D3 B 1533 SF 3 3 R3 200 8D4 B 1515 SF 3 3 R3 200 8D5 B 1533 SF 3 3 R3 200 8D6 B 1515 SF 3 3 R3 200 89120 SF 18 18 46EE1 C 992 SF 2 2 R3 200 5E1D C 88 SF 0 0 N/A 0 0E2 D 590 SF 1 1 R3 200 3E3 D 592 SF 1 1 R3 200 3E4 E 1054 SF 2 2 R3 200 5E5 C 991 SF 2 2 R3 200 5E5D C 86 SF 0 0 N/A 0 0E6 D 591 SF 1 1 R3 200 3E7 D 592 SF 1 1 R3 200 3E8 E 1054 SF 2 2 R3 200 56630 SF 12 12 32GRAND TOTAL 39107 SF 66 66 188REVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 RESORT VIEW APARTMENTSLA COSTA GOLF COURSE177.77'209.80'200.83'8.99'177.32'THE AREA OF THE SITE WITH A GRADE OVER 40% SLOPE IS LESS THAN 10,000 SF. PER 21.95.140.B.1(C)THE AMOUNT OF CUT/FILL PER ACRE IS 5,653.25 WHICH IS UNDER THE 7999 CUBIC YD/ACRE ACCEPTABLE LIMIT.THE HIGHEST POINT ON THE SITE IS ALONG A SIDE YARD BETWEEN THE ADJACENT PROPERTIES. WE’RE GRADING EVERYTHING DOWN TO MATCH STREET LEVEL.1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:40:09AM4PLANNINGCOMMISSIONREV1/13/2020 8:40:09 AMBNR DEVELOPMENTSLOPE ANALYSIS G-004RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT G-004 // SLOPE ANALYSIS // ISSUED: 03/18/191" = 30'-0"1SITE SLOPE ANALYSISREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 DNDNSIGHT DISTANCE LINE, TYP.SIGHT DISTANCE LINE, TYP.SIGHT DISTANCE LINE, TYP.SIGHT DISTANCE LINE, TYP.O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/6O/3O/3WWWWWWWWWO/*O/*O/*PPPƇ/*Ƈ/*Ƈ/*10' - 0"FRONT SETBACK10' - 0"5' - 0"REAR SETBACK10' - 0"SIDE SETBACK5' - 0"BUILDING CBUILDING DBUILDING ABUILDING E1 A-2012 A-2022 A-2011 A-2021 A-2113 A-2112 A-2114 A-2113 A-2131 A-2134 A-2132 A-2133 A-214BUILDING B75.29 ft68.51 ftP.L.P.L.11' - 3"SIDE YARD ENTRY SETBACK8 UNITSONE LEVEL APARTMENT DWELLINGS. (4) ONE BEDROOMS, (4) TWO BEDROOM.TWO LEVELS OF TYPE-V CONSTRUCTION OVER TYPE-I CONCRETE PODIUM.1 A-2144 A-2142 A-214LA COSTA GOLF COURSE(6) THREE BEDROOM WITH THREE LEVELS OF LIVING OVER ONE LEVEL OF PARKING. LOBBY SPACE ON ENTRY LEVEL. THREE LEVELS OF TYPE-V CONSTRUCTION OVER TYPE-I CONCRETE PODIUM(6) THREE BEDROOM UNITS WITH THREE LEVELS OF LIVING OVER ONE LEVEL OF PARKING. COMMUNITY GYM SPACE ON GROUND FLOOR.THREE LEVELS OF TYPE-V CONSTRUCTION OVER TYPE-I CONCRETE PODIUM(3) THREE BEDROOM TOWNHOUSES. EACH HAS PARKING AND BEDROOM WITH TWO LEVELS OF LIVING ABOVE. SEPARATE ROOFTOP DECK FOR EACH UNIT. (3) THREE BEDROOM TOWNHOUSES. EACH HAS PARKING AND BEDROOM WITH TWO LEVELS OF LIVING ABOVE. SEPARATE ROOFTOP DECK FOR EACH UNIT. TYPE-V CONSTRUCTION.VIEJO CASTILLA WAYNNOTES:1. ALL ROOF MOUNTED EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH BUILDING DEPARTMENT POLICY 80-62. TOTAL IMPERVIOUS AREA: 21,576 SF3. FIRE PROTECTION SPRINKLER LEVEL NFPA 13 OR GREATER FOR ALL BUILDINGS4. ALL WINDOWS TO BE RECESSED A MINIMUM OF 3" FROM EXTERIOR SURFACE.R1R1R1R1R1BITUMOUS ROOFING WHITEMETAL FENCING. MAX 6' TALL. EXISTING1 A-2124 A-2122 A-2123 A-212BUILDING TO NORTHBUILDING TO WESTSAFTEY GATESAFTEY GATEADA ACCESS PATH0° 00' 00"200.83'SWLLLLLLLLLLLL90° 00' 00"177.32'NW0° 00' 00"209.80'NE90° 00' 00"177.77'NE2° 52' 05"8.99'NES-12S-2S-2S-2S-12S-2S-1S-1S-1S-2S-11S-2S-2S-12(E) 8" SEWER MAIN PER DWG 168-10.NOT ON DRAWING. 30' FROM P.L. SEE PRELIMINARY GRADING PLAN FOR FURTHER INFORMTAION1" WATER SERVICE & METERFIRE SPRINKLER SERVICE BLDG. A THRU E1" WATER SERVICE & METERBROW DITCH ON TOP OF LANDSCAPING RETAINING WALLS-12S-12ART SCULPTURE WITHIN FRONT YARD SETBACK PER LANDSCAPING. NOT TO EXCEED 42" IN HEIGHT1. ALL NOTES LABELED NOT IN PERMIT(NIP) ARE NOT PART OF THIS APPLICATION. 2. SOILS EXCAVATION, RECOMPACTION, AND GRADING TO FOLLOW PARAMETERS STATED IN GEOLOGICAL REPORT/UPDATE PREPARED BY GEOSOILS, INC. DATED APRIL 16, 2010.3. ALL NEW GRADED SLOPES SHALL BE NO STEEPER THAN 2H:1V 4. ALL SURFACE WATER MUST DRAIN AWAY FROM BUILDING, A MINIMUM OF 5% WITHIN FIRST 10' HORIZONTAL (2% FOR IMPERVIOUS SURFACES).5. ALL LOOSE FOUNDATION EXCAVATION MATERIAL SHALL BE REMOVED PRIOR TO COMMENCEMENT OF FRAMING. SLOPES DISTURBED BY CONSTRUCTION ACTIVITIES SHALL BE RESTORED.6. ALL RETAINING WALLS SHALL BE PROVIDED WITH A SUBDRAIN SYSTEM TO PREVENT POSSIBLE HYDROSTATIC PRESSURE BEHIND THE WALL. 7. ALL ROOF AND PAD DRAINAGE SHALL BE CONDUCTED TO THE STREET IN AN ACCEPTABLE MANNER. IF WATER SHALL BE DISPERSED ON TO DESCENDING SLOPES, ACQUIRE SPECIFIC APPROVAL FROM THE GRADING SECTION AND THE CONSULTING GEOLOGIST AND/OR SOIL ENGINEER. 8. ALL DECK DRAINAGE SHALL BE COLLECTED AND CONDUCTED TO AN APPROVED LOCATION IN A NON-EROSIVE DEVICE. 9. CONTRACTOR TO REVIEW BOTH PROPOSED SITE DRAINAGE CONDITIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES OR CONDITIONS THAT DO NOT ALLOW FOR POSITIVE DRAINAGE AWAY FROM BUILDING AND OTHER STRUCTURES. DO NOT COMMENCE SITE DRAINAGE WORK UNTIL ALL DISCREPANCIES AND CONDITIONS HAVE BEEN REVIEWED BY ARCHITECT.10. ALL PIPING SHALL BE 4-INCH DIAMETER, U.O.N. NOTIFY ARCHITECT OF DISCREPANCIES OR UNDERSIZED PIPING SYSTEMS.11. ALL SOLID DRAINAGE PIPING SHALL HAVE A MINIMUM SLOPE OF 2% UNLESS OTHERWISE NOTED.12. 5% DRAINAGE AROUND/AWAY FROM BUILDING FOR A MINIMUM DISTANCE OF 10'. ALTERNATIVELY, SWALES WITH SLOPE OF 2% SHALL BE LOCATED WITHIN 10' OF BUILDING FOUNDATION. 13. ALL EXISTING TREES TO REMAIN, UNLESS OTHERWISE NOTED. PROTECT EXISTING TREES DURING ALL CONSTRUCTION OPERATIONS, AS NEEDED.14. ARCHITECT TO VERIFY ALL DRAIN LOCATIONS PRIOR TO THEIR INSTALLATION.15. A COPY OF THE CONSTRUCTION DOCUMENTS OR A COMPARABLE DOCUMENT INDICATING THE INFORMATION FROM E16. THE PANEL OR SUBPANEL SHALL PROVIDE CAPACITY TO INSTALL A 40-AMPERE MINIMUM DEDICATED BRANCH CIRCUIT AND SPACE(S) RESERVED TO PERMIT INSTALLATION OF A BRANCH CIRCUIT OVERCURRENT PROTECTIVE DEVICE17. THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE OVERCURRENT PROTECTIVE DEVICE SPACE(S) RESERVED FOR FUTURE EV CHARGING AS EV CAPABLE. THE RACEWAY TERMINATION LOCATION SHALL BE PERMANENT AND VISIBLY MARKED EV CAPABLE. PROPERTY LINESETBACKBUILDING FOOTPRINTEXISTING TREEHOSE BIBSITE LEGENDMETAL FENCEWOOD FENCELANDSCAPING WALLLOCATION OF UTILITY STUB-OUTS AND CLEAN-OUTSPROPOSED UTILITIESSITE NOTES*HEIGHTHB1iWALL TAGTYPEHEIGHT*HEIGHTS-2DECORATIVE MASONRY PAVINGSITE LANDSCAPING FINISH LEGENDS-12NATURAL GREY CONCRETE PAVINGS-22GARAGE DRIVEWAY AND APRON. DECORATIVE PAVERSS-1PRODUCTION CONCRETES-11ARCHITECTURAL TURF1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:40:16AM4PLANNINGCOMMISSIONREV1/13/2020 8:40:16 AMBNR DEVELOPMENTSITE PLAN A-101RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-101 // SITE PLAN // ISSUED: x1" = 10'-0"1SITE PLANREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 SIGHT DISTANCE LINE, TYP.SIGHT DISTANCE LINE, TYP.SIGHT DISTANCE LINE, TYP.SIGHT DISTANCE LINE, TYP.EXISTING TOPOGRAPHY A-3033209' - 9 1/2"VIEJO CASTILLA TO GOLF COURSEADJACENT PROPERTY BUILDING12347891012116ADA - VAN5ENTRY LOBBYSTREET ENTRYCOURTYARDAMENITIES132 SFMECHANICAL ROOM242219 2034 363331 32484745 46444321 233513 15 18172725 28 302916142637 38 4039 41 42TYPICAL8' - 6"8' - 0"8' - 6"10' - 0"10' - 0"TYPICAL20' - 0"TYPICAL20' - 0"20' - 0"TRASHTRASH49PROPOSED DRIVEWAYEXISTING TOPOGRAPHY44' - 7"41' - 9"45' - 5"42' - 7"1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:40:49AM4PLANNINGCOMMISSIONREV1/13/2020 8:40:49 AMBNR DEVELOPMENTPARKINGDESIGN A-102RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-102 // PARKING DESIGN // ISSUED: xPARKING SCHEDULETYPE COUNT DESCRIPTIONGARAGE36COVERED - ADA 1COVERED12PARKING TOTAL 491/16" = 1'-0"3DRIVEWAY SECTION - NORTH1/16" = 1'-0"1PARKING PLAN1/16" = 1'-0"4DRIVEWAY SECTION - SOUTHREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 UPDNUPDNDNDN DNDNDNUP UP UP445 SFA1450 SFA2425 SFA3423 SFB1452 SFB2450 SFB3473 SFAG1479 SFAG2441 SFAG3448 SFBG1486 SFBG2485 SFBG3ADA ACCESS FOR UNIT A1P.L.163 SFBED 03156 SFBED 03152 SFBED 0364 SFBATH64 SFBATH55 SFBATH106 SFCIRCULATION85 SFCIRCULATION160 SFCIRCULATION30 SFCLOSET30 SFCLOSET33 SFLAUNDRY32 SFLAUNDRY430 SFGARAGE463 SFGARAGE461 SFGARAGEP.L.4687 SFLIVING152 SFKITCHEN131 SFKITCHEN38 SFPOWDER42 SFPOWDER695 SFLIVING597 SFLIVING112 SFKITCHEN39 SFDECK42 SFDECK35 SFDECKJULIET BALCONY130 SFBED 02143 SFBED 02138 SFBED 02271 SFMASTER BEDROOM271 SFMASTER BEDROOM229 SFMASTER BEDROOMMASTER BATHMASTER BATHMASTER BATHBATHBATHBATHCLOSETCLOSETCLOSETMASTERCLOSETMASTERCLOSETMASTERCLOSET176 SFCIRCULATION178 SFCIRCULATION171 SFCIRCULATION221 SFROOF DECK242 SFROOF DECK239 SFROOF DECKSHARED ROOF(SOLAR)903 SFA1936 SFA2790 SFA3783 SFB1928 SFB2896 SFB3859 SFA11627 SFA2RedundantAreaA3748 SFB1850 SFB2846 SFB3247 SFA1D246 SFA2D224 SFA3D218 SFB1D239 SFB2D243 SFB3D1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:40:57AM4PLANNINGCOMMISSIONREV1/13/2020 8:40:57 AMBNR DEVELOPMENTFLOOR PLANTYPE A A-110RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-110 // FLOOR PLAN TYPE A // ISSUED: x5LEVEL 011/8" = 1'-0"1EAST SIDE VARIATION LEVEL 011/8" = 1'-0"2EAST SIDE VARIATION LEVEL 021/8" = 1'-0"3EAST SIDE VARIATION LEVEL 031/8" = 1'-0"4PLANNING A46LEVEL 027LEVEL 038LEVEL 04REVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 DNUPDN UPUPDNDN UP1520 SFD11504 SFD21519 SFC11522 SFC210' - 2"11' - 7"12' - 1"21' - 0"6' - 0"10' - 9"14' - 11"12' - 0"374 SFLIVING85 SFDINING143 SFDECK106 SFKITCHEN128 SFBED 03123 SFBED 02180 SFMASTER BEDROOM374 SFLIVING108 SFKITCHEN85 SFDINING125 SFBED 0380 SFMASTER BATH36 SFBATH58 SFBATH37 SFLAUNDRY377 SFLIVING92 SFDINING106 SFKITCHEN150 SFBED 02113 SFBED 03184 SFMASTER BEDROOM101 SFMASTER BATH36 SFLAUNDRY58 SFBATH25 SFCLOSET25 SFCLOSET102 SFCIRCULATION37 SFBATH1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:41:01AM4PLANNINGCOMMISSIONREV1/13/2020 8:41:01 AMBNR DEVELOPMENTFLOOR PLANTYPE B A-130RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-130 // FLOOR PLAN TYPE B // ISSUED: x1" = 40'-0"2TYPE B - 021/8" = 1'-0"4BUILDING C LEVEL 03 & 04 (BUILDING D IS MIRRORED)1/8" = 1'-0"1BUILDING C LEVEL 02 (BUILDING D IS MIRRORED)REVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 DNUPDNUP/1 A-150344 SFLIVING63 SFBATH491 SFLIVING43 SFBATH32 SFCLOSET146 SFBEDROOM125 SFBEDROOM71 SFADA BATH84 SFDECK165 SFBEDROOM165 SFBEDROOM11' - 10"11' - 1"16' - 10"992 SFE1590 SFE288 SFE1D5' - 0"12' - 2"11' - 10"/2 A-15010' - 7"162 SFBEDROOM346 SFLIVING152 SFBEDROOM434 SFLIVING64 SFBATH98 SFKITCHEN29 SFCLOSET63 SFBATH19 SFLAUNDRY164 SFBEDROOM43 SFBATH11' - 1"8' - 0"12' - 6"14' - 1"7' - 6"11' - 0"10' - 7"11' - 10"592 SFE31054 SFE41. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:41:04AM4PLANNINGCOMMISSIONREV1/13/2020 8:41:04 AMBNR DEVELOPMENTFLOOR PLANTYPE C, D & E A-150RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-150 // FLOOR PLAN TYPE C, D & E // ISSUED: x1/4" = 1'-0"2UNITS TYPE D1/4" = 1'-0"1UNITS TYPE EREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 SIGHT DISTANCE LINE, TYP.SIGHT DISTANCE LINE, TYP.SIGHT DISTANCE LINE, TYP.SIGHT DISTANCE LINE, TYP.BUILDING CBUILDING DBUILDING ABUILDING EBUILDING BR1R1R1R1R1R1R1R1R1R1R1R1R1R1ALL ROOF MOUNTED EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH BUILDING DEPARTMENT POLICY 80-6NMECHANICAL EQUIPMENT1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:41:11AM4PLANNINGCOMMISSIONREV1/13/2020 8:41:11 AMBNR DEVELOPMENTSITE ROOF PLAN A-160RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-160 // SITE ROOF PLAN // ISSUED: 03/18/191" = 10'-0"1SITE ROOF PLANREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 E1 FF69' -9 3/4"A1 FF75' -7 1/2"BUILDING A - EASTBUILDING C - EASTBUILDING E - EASTC1 FF75' -1 3/4"C0 FF69' -7 1/4"A1+ 34' - 5"A1+ 31' - 7"C1+ 34' - 4"C0+ 48' - 2"E1+ 36' - 11"C0+ 39' - 5"S1A2A4A3S1A4A3A4A1A1A4A1A4A2A1+ 38' - 8"EXISTING GRADEC1+ 42' - 7"C0+ 50' - 11"A2GA1S1A4E1 FF69' -9 3/4"D1 FF76' -0"BUILDING B - WESTBUILDING D - WESTBUILDING E - WESTB286' -0"B1 FF77' -0 1/4"B1+ 33' - 1"D0+ 50' - 8"D0+ 47' - 11"E1+ 36' - 11"D0 FF69' -10"A4A1EF1A2A1A1A2W1A4A1W1GA1A3A2EF1EXISTING GRADED1+ 41' - 9"A3A2A2B2+ 29' - 3"B2+ 28' - 4"E1+ 31' - 11"E1+ 34' - 5"A1STUCCO -SMOOTH FINISH, WHITEA3STUCCO -SMOOTH FINISH, ACCENT COLORGGLASS / GLASS RAILINGM1METAL 01 -ANODIZED / PAINTEDW1WOOD FINISH 01EXTERIOR FINISH LEGENDAL1ALUMINUM -PAINTEDA2STUCCO -SMOOTH FINISH, GRAYEF1EXTERIOR FINISH 01D1DOOR FINISH -TBDS1STONE, WHITE RECTANGULARBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBUILDING CBUILDING DBUILDING ABUILDING BBUILDING E1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:42:52AM4PLANNINGCOMMISSIONREV1/13/2020 8:42:52 AMBNR DEVELOPMENTSITEELEVATIONS A-201RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-201 // SITE ELEVATIONS // ISSUED: x1/8" = 1'-0"1SITE ELEVATION EAST (VIEJO CASTILLA FRONTAGE)1/8" = 1'-0"2SITE ELEVATION WEST (REAR)REVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 E1 FF69' -9 3/4"BUILDING C BEYONDBUILDING D BEYONDE1+ 36' - 11"A1A2GA4A2A1A3A1A4M1EXISTING GRADEE1+ 31' - 11"E1+ 34' - 5"A1 FF75' -7 1/2"B286' -0"BUILDING E BEYONDBUILDING C BEYONDBUILDING D BEYONDB1+ 33' - 2"A1+ 33' - 10"GA1A2A1A1A2D1M1A1+ 38' - 8"EXISTING GRADERAILING & LANDSCAPING WALLB2+ 29' - 3"B2+ 24' - 2"A1+ 33' - 10"B1+ 38' - 3"B1+ 33' - 2"A1STUCCO -SMOOTH FINISH, WHITEA3STUCCO -SMOOTH FINISH, ACCENT COLORGGLASS / GLASS RAILINGM1METAL 01 -ANODIZED / PAINTEDW1WOOD FINISH 01EXTERIOR FINISH LEGENDAL1ALUMINUM -PAINTEDA2STUCCO -SMOOTH FINISH, GRAYEF1EXTERIOR FINISH 01D1DOOR FINISH -TBDS1STONE, WHITE RECTANGULARBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBUILDING CBUILDING DBUILDING ABUILDING BBUILDING E1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:43:31AM4PLANNINGCOMMISSIONREV1/13/2020 8:43:31 AMBNR DEVELOPMENTSITEELEVATIONS A-202RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-202 // SITE ELEVATIONS // ISSUED: x1/8" = 1'-0"2SITE ELEVATION NORTH1/8" = 1'-0"1SITE ELEVATION SOUTH (GOLF COURSE FRONTAGE)REVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 A1A2A1S1A1 FF75' -7 1/2"A285' -0"A396' -0"A4106' -0"A1+ 31' - 7"A3A1+ 38' - 8"A2EXISTING GRADEGAL1GS1A1A1 FF75' -7 1/2"A285' -0"A396' -0"A4106' -0"A1+ 33' - 10"EXISTING GRADEA3GA1A1A1 FF75' -7 1/2"A285' -0"A396' -0"A4106' -0"A2A1+ 38' - 8"EXISTING GRADEA2GA1 FF75' -7 1/2"A285' -0"A396' -0"A4106' -0"A1+ 20' - 4"A1+ 34' - 5"EXISTING GRADEA1+ 38' - 8"A1STUCCO -SMOOTH FINISH, WHITEA3STUCCO -SMOOTH FINISH, ACCENT COLORGGLASS / GLASS RAILINGM1METAL 01 -ANODIZED / PAINTEDW1WOOD FINISH 01EXTERIOR FINISH LEGENDAL1ALUMINUM -PAINTEDA2STUCCO -SMOOTH FINISH, GRAYEF1EXTERIOR FINISH 01D1DOOR FINISH -TBDS1STONE, WHITE RECTANGULARBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EELEVATION NOTES1. ALL ROOF MOUNTED EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH BUILDING DEPARTMENT POLICY 80-61. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:44:08AM4PLANNINGCOMMISSIONREV1/13/2020 8:44:08 AMBNR DEVELOPMENTELEVATIONS -BUILDING A A-211RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-211 // ELEVATIONS -BUILDING A // ISSUED: x1/8" = 1'-0"4BUILDING A EAST1/8" = 1'-0"2BUILDING A NORTH1/8" = 1'-0"1BUILDING A SOUTH1/8" = 1'-0"3BUILDING A WESTREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 A1STUCCO -SMOOTH FINISH, WHITEA3STUCCO -SMOOTH FINISH, ACCENT COLORGGLASS / GLASS RAILINGM1METAL 01 -ANODIZED / PAINTEDW1WOOD FINISH 01EXTERIOR FINISH LEGENDAL1ALUMINUM -PAINTEDA2STUCCO -SMOOTH FINISH, GRAYEF1EXTERIOR FINISH 01D1DOOR FINISH -TBDS1STONE, WHITE RECTANGULARB286' -0"B396' -8"B4106' -8"B1 FF77' -0 1/4"B2+ 29' - 3"B2+ 24' - 2"27' - 4"GA1A2EXISTING GRADEB286' -0"B396' -8"B4106' -8"B1 FF77' -0 1/4"A4A1A3A2A2B1+ 33' - 8"B2+ 29' - 3"EXISTING GRADEB286' -0"B396' -8"B4106' -8"B1 FF77' -0 1/4"B1+ 33' - 8"B2+ 24' - 9"A2A2A3A225' - 9"27' - 10"EXISTING GRADEA1A2B286' -0"B396' -8"B4106' -8"B1 FF77' -0 1/4"B1+ 33' - 8"B1+ 30' - 10"B2+ 24' - 9"A3A129' - 9"EXISTING GRADEBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EELEVATION NOTES1. ALL ROOF MOUNTED EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH BUILDING DEPARTMENT POLICY 80-61. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:44:44AM4PLANNINGCOMMISSIONREV1/13/2020 8:44:44 AMBNR DEVELOPMENTELEVATIONS -BUILDING B A-212RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-212 // ELEVATIONS -BUILDING B // ISSUED: 03/12/191/8" = 1'-0"1B SOUTH1/8" = 1'-0"2B NORTH1/8" = 1'-0"3B WEST1/8" = 1'-0"4B EASTREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 A1A1A3S1A4C1 FF75' -1 3/4"C286' -0"C396' -0"C4106' -0"C5116.00C0 FF69' -7 1/4"C1+ 45' - 5"C0+ 48' - 2"A1EXISTING GRADEA4A4A2A3A1A1A2A3A1C1 FF75' -1 3/4"C286' -0"C396' -0"C4106' -0"C5116.00C0 FF69' -7 1/4"C1+ 45' - 5"EXISTING GRADEGA1A2A2A1A4C1+ 45' - 5"C0+ 39' - 11"EXISTING GRADEA3C1 FF75' -1 3/4"C286' -0"C396' -0"C4106' -0"C5116.00C1+ 45' - 5"A4A1A2A3A239' - 11"EXISTING GRADEA1STUCCO -SMOOTH FINISH, WHITEA3STUCCO -SMOOTH FINISH, ACCENT COLORGGLASS / GLASS RAILINGM1METAL 01 -ANODIZED / PAINTEDW1WOOD FINISH 01EXTERIOR FINISH LEGENDAL1ALUMINUM -PAINTEDA2STUCCO -SMOOTH FINISH, GRAYEF1EXTERIOR FINISH 01D1DOOR FINISH -TBDS1STONE, WHITE RECTANGULARBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EELEVATION NOTES1. ALL ROOF MOUNTED EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH BUILDING DEPARTMENT POLICY 80-61. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:45:29AM4PLANNINGCOMMISSIONREV1/13/2020 8:45:29 AMBNR DEVELOPMENTELEVATIONS -BUILDING C & D A-213RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-213 // ELEVATIONS -BUILDING C & D // ISSUED: x1/8" = 1'-0"3BUILDING C EAST1/8" = 1'-0"4BUILDING C WEST1/8" = 1'-0"2BUILDING C NORTH1/8" = 1'-0"1BUILDING C SOUTHREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 E1 FF69' -9 3/4"E391' -0"E4100' -0"E281' -0"E1+ 36' - 11"EXISTING GRADEE1+ 31' - 11"E1 FF69' -9 3/4"E391' -0"E4100' -0"E281' -0"E1+ 36' - 11"A2A1A2A2EXISTING GRADEE1+ 34' - 5"E1+ 31' - 11"A4A3GE1 FF69' -9 3/4"E391' -0"E4100' -0"E281' -0"E1+ 36' - 11"A2A1A4A4M1A1A2EXISTING GRADEE1+ 31' - 11"E1+ 34' - 5"A2A3E1 FF69' -9 3/4"E391' -0"E4100' -0"E281' -0"A4A1A1A3A1S1M1E1+ 36' - 11"EXISTING GRADEBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBUILDING CBUILDING DBUILDING ABUILDING BBUILDING E1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:46:07AM4PLANNINGCOMMISSIONREV1/13/2020 8:46:07 AMBNR DEVELOPMENTELEVATIONS -BUILDING E A-214RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-214 // ELEVATIONS -BUILDING E // ISSUED: x1/8" = 1'-0"3BUILDING E WEST1/8" = 1'-0"1BUILDING E SOUTH1/8" = 1'-0"2BUILDING E NORTH1/8" = 1'-0"4BUILDING E EASTREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 E1 FF69' -9 3/4"D1 FF76' -0"B286' -0"B1 FF77' -0 1/4"D0 FF69' -10"EXISTING TOPOGRAPHYP.L.P.L.33' - 9" TO EG42' - 0" TO FG47' - 6" TO FG37' - 5" TO EG25' - 4" TO EG34' - 4" TO FGEXISTING GRADE38' - 9" TO FG37' - 10" TO FG7' - 0"31' - 11" TO FG33' - 2" TO EGE1 FF69' -9 3/4"31' - 11" TO FGA1 FF75' -7 1/2"A285' -0"C1 FF75' -1 3/4"C0 FF69' -7 1/4"EXISTING TOPOGRAPHYP.L.P.L.75.140 ft75.797 ft75.630 ft48' - 0" TO FG46' - 2" TO EG33' - 9" TO EG35' - 3" TO EG33' - 8" TO EG34' - 3" TO FG38' - 8" TO FGEXISTING GRADE36' - 11" TO FG50' - 11" TO FGBUILDING CBUILDING DBUILDING ABUILDING BBUILDING E121. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:46:37AM4PLANNINGCOMMISSIONREV1/13/2020 8:46:37 AMBNR DEVELOPMENTSECTIONS A-301RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-301 // SECTIONS // ISSUED: 03/13/191/8" = 1'-0"1SITE SECTION 011/8" = 1'-0"2SITE SECTION 05REVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 A1 FF75' -7 1/2"B286' -0"B396' -8"B4106' -8"B1 FF77' -0 1/4"A285' -0"A396' -0"A4106' -0"P.L.P.L.33' - 3"28' - 11"29' - 3"28' - 1"33' - 10"30' - 3"38' - 8"36' - 4"31' - 6"EXISTING GRADED1 FF76' -0"D4106' -0"D5116.00C1 FF75' -1 3/4"C286' -0"C396' -0"C4106' -0"D396' -0"D286' -0"C5116.0034' - 1" TO EG36' - 9" TO FG41' - 9" TO FG41' - 9" TO FG39' - 8" TO EG45' - 1" TO EG42' - 7" TO FGEXISTING GRADE44' - 7" TO FG50' - 11" TO FG45' - 5" TO FGBUILDING CBUILDING DBUILDING ABUILDING BBUILDING E121. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:47:15AM4PLANNINGCOMMISSIONREV1/13/2020 8:47:15 AMBNR DEVELOPMENTSECTIONS A-302RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-302 // SECTIONS // ISSUED: 03/13/191/8" = 1'-0"1SITE SECTION 041/8" = 1'-0"2SITE SECTION 02REVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 O/6O/6O/6O/6O/6 78' - 0" 79' - 0" 80' - 0" 81' - 0" 82' - 0" 76' - 0" 77' - 0" 78' - 0" 79' - 0" 80' - 0" 81' - 0" 82' - 0" 75' - 0" DNO/6O/6O/6O/6O/6O/6 84' - 0" 85' - 0" 86' - 0" 81' - 0" 82' - 0" 83' - 0" 81' - 0" 82' - 0" 83' - 0" 84' - 0" 85' - 0" 86' - 0" 88' - 0" 89' - 0" 87' - 0" B286' -0"B PAD76.202 A-303EXISTING TOPOGRAPHYP.L.2' - 10"10' - 0"NEW TOPOGRAPHY3' - 8"E1 FF69' -9 3/4"D1 FF76' -0"4 A-3033 A-102B286' -0"B PAD76.20D0 FF69' -10"3 A-3031 A-3033' - 0"EXISTING TOPOGRAPHY6 7/8"18R12"TYPE A10R12"6 3/8"TYPE A5 A-3036 3/4"21R12"TYPE A11' - 2"86.08 ft86.08 ft86.13 ft84.83 ft4' - 9"9' - 9"81.14 ft78.50 ft75.34 ft75.34 ft82.50 ft85.49 ftPLANTING PER LANDSCAPING DRAWINGSPLANTING PER LANDSCAPING DRAWINGSEF1EF1EXISTING GRADEEXISTING GRADE2 A-3032' - 7"6' - 4"P.L.EXISTING TOPOGRAPHY LINEP.L.EXISTING TOPOGRAPHY LINENEW TOPOGRAPHY LINERETAINING WALLS2 A-30310' - 0"3' - 8"2' - 10"D1 FF76' -0"2 A-303D286' -0"D0 FF69' -10"P.L.EXISTING TOPOGRAPHY LINE2' - 10"2' - 10" 6' - 4" 10' - 0"1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:47:38AM4PLANNINGCOMMISSIONREV1/13/2020 8:47:38 AMBNR DEVELOPMENTSECTIONS A-303RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-303 // SECTIONS // ISSUED: 03/18/191/4" = 1'-0"1SITE STAIRS 01 A1/4" = 1'-0"2SITE STAIRS 01 B1/4" = 1'-0"3NORTH RETAINING WALL1/4" = 1'-0"4SOUTH RETAINING WALL1/4" = 1'-0"5SITE STAIR 021/4" = 1'-0"6SITE STAIRS WEST SIDE PLANREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 B286' -0"A285' -0"78.50 ft79.80 ft7.3%17' - 11 1/4"17.94'5' - 0"5'18' - 8"18.67'4' - 0 1/4"4.02'15' - 9 5/8"15.8'5' - 0"5'12' - 10 1/8"12.85'4' - 0"4'18' - 2 1/8"18.18'5' - 0"5'21' - 3 1/8"21.26'5' - 0"5'21' - 3 1/8"21.26'8' - 10 1/4"8.85'7.8%7.9%82.50 ft4.9%4.8%84.00 ft4.7%85.00 ft86.00 ft81.25 ft4.7%79' - 3"70' - 8"5 A-3043 A-3044 A-30483.13 ftB286' -0"B1 FF77' -0 1/4"1 A-304A285' -0"1 A-304BUILDING BBUILDING AHANDRAIL BOTH SIDESHANDRAIL BOTH SIDESHANDRAIL BOTH SIDES4.7%4.8%4.9%7.9%7.8%7.3%4.7%83.13 ft82.50 ft81.25 ft79.80 ft84.00 ft85.00 ft86.00 ft11' - 3"1 A-3041. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:47:42AM4PLANNINGCOMMISSIONREV1/13/2020 8:47:42 AMBNR DEVELOPMENTSECTIONS A-304RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-304 // SECTIONS // ISSUED: 06/12/191/8" = 1'-0"1SOUTH PEDESTRIAN ACCESS PATH SECTION1/4" = 1'-0"5SOUTH PEDEISTRIAN PATH CROSS SECTION 21/4" = 1'-0"3SOUTH PEDEISTRIAN PATH CROSS SECTION 11/8" = 1'-0"2ADA PATH PLAN1/4" = 1'-0"4SOUTH PEDEISTRIAN PATH CROSS SECTION 3REVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 (E) SPLIT LEVEL TOWNHOMES TO NORTHP.L.P.L.31' - 11" TO FG38' - 9"33' - 7" TO EG10' PER CODE(E) TWO STORY DEVLEPMENT WITH TALL ROOF TO WEST OF PROPERTY10' - 0"10' - 0"10' - 0"10' - 0"P.L.P.L.41' - 9"10' - 0"10' - 0"10' - 0"10' - 10"BUILDING CBUILDING DBUILDING ABUILDING BBUILDING E121. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:48:22AM4PLANNINGCOMMISSIONREV1/13/2020 8:48:22 AMBNR DEVELOPMENTCONTEXTSECTIONS A-305RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-305 // CONTEXT SECTIONS // ISSUED: 06/13/191" = 10'-0"1CONTEXT SECTION 011" = 10'-0"2CONTEXT SECTION 023CONTEXT SECTIONS LOCATION(E) BUILDING ACROSS VIEJO CASTILLA WAY. 2 STORIES OVER 1 PARKING LEVELREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 BUILDING CBUILDING DBUILDING ABUILDING BBUILDING EBACDE1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:48:24AM4PLANNINGCOMMISSIONREV1/13/2020 8:48:24 AMBNR DEVELOPMENT3D RENDERINGS A-900RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-900 // 3D RENDERINGS // ISSUED: 06/05/19CONTEXT VIEWS KEYBACDEREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 BUILDING CBUILDING DBUILDING ABUILDING BBUILDING EDABC1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:48:26AM4PLANNINGCOMMISSIONREV1/13/2020 8:48:26 AMBNR DEVELOPMENT3D RENDERINGS A-901RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-901 // 3D RENDERINGS // ISSUED: 06/05/19CONTEXT VIEWS KEYABCDREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.2. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.), UNLESS OTHERWISE NOTED. 3. AS-BUILT CONDITIONS TO BE VERIFIED.4. ALL DIMENSIONS SHOULD BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK.Sheet TitleSheet NumberCLIENT5. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION.6. DRAWINGS REPRESENT DESIGN INTENT ONLY - CONTRACTOR RESPONSIBLE FOR MEANS AND METHODS. DateSizeRevision #24" x 36"392 camino de estrellasan clemente, california 92672949 325 3001 phone949 203 3339 faxfoxlin.com webinfo@foxlin.com emailJob #PROJECT ADDRESSarchitecturedesignconsultingDRAWING SETGENERAL NOTESSDP 2018-0022/HDP 2018-0006 (DEV2017-0225) RESORT VIEW APARTMENTSC:\Users\david\Desktop\RV Desktop\RV Revit\1710-Resort View-[19]-191226_Discretionary Submittal Final Set Edit.rvt1/13/2020 8:48:27AM4PLANNINGCOMMISSIONREV1/13/2020 8:48:27 AMBNR DEVELOPMENTMATERIALSBOARD A-902RESORT VIEW APARTMENTSPRE-DESIGNVIEJO CASTILLA WAYCARLSBAD, CA 920091710RESORT VIEW APARTMENTSVIEJO CASTILLA WAYCARLSBAD, CA 920091710BNR DEVELOPMENT A-902 // MATERIALS BOARD // ISSUED: 08/27/19ABCDEFGHITANDARK TANDARK BROWNISH GREYWARM GREYWHITESTONE TILE LIGHT TONEDECORTATIVE CONCRETE DRIVEWAYGLASS RAILINGSTONE TILE LIGHT TONEBACFHIDECBDD1. ALL ROOF MOUNTED EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH BUILDING DEPARTMENT POLICY 80-62. ALL WINDOWS TO BE RECESSED A MINIMUM OF 3" FROM EXTERIOR SURFACE.BAIREVISION SCHEDULE#DISCRIPTIONBYISSUED TODATE4PLANNING COMMISSION REVDMCARLSBAD01/13/2020REVISION DATES# REVISION DATE4 01/13/2020 SDXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX BLDG. LINE(75.50) TC(75.00) FL(5.5%)N00° 03' 46"W 105.00'N00° 03' 45"W 84.15'N89° 56' 19"E 178.00'N89° 56' 19"E 178.00'N89° 56' 14"E177.32'N00° 03' 46"W 105.00'N00° 03' 46"W 105.00'D=3°44'06",L=20.86',R=320.00'(6.0%)(73.90) TC(73.40) FL0" CF74.26 FL2%10%0" CF75.51 FS6" CF74.44 FL/GB1%0.5%6" CF74.80 FL/GB1%74.85FS74.93FF75.10FF2"75.10FF3"4"74.93FF74.85FF74.77FFGARAGEGARAGEGARAGE75.30FS 2%75.30FS6" CF75.20 FS5%74.69FS 75.10FF74.77FS74.85FF6" CF74.70 FL/GB3%74.85 FS1.5%74.69FS3.5%74.77 FS 75.10FFGARAGEFF= 75.14PAD= 74.3FF= 69.37PAD= 68.6(5.8%)2%6" CF74.60 FL/GB74.77FF2.5%3.5%75.38FF2%75.38FF75.38FF75.30FS75.30FS75.30FS2%2%6" CF75.20 FS6" CF75.202"2"2"GARAGEGARAGEGARAGE2%2%75.55FF75.55FF75.55FFFF= 75.63PAD= 74.96" CF75.44 FL/GB2%6" CF76.15 FS6" CF75.55 FL6" CF75.64 FL6" CF75.77 FL0.5%6" CF75.80 FL75.82FS75.90FF76.07FF2"76.07FF3"4"75.90FF75.82FF75.74FFGARAGEGARAGEGARAGE75.66FS 76.07FF75.74FS75.82FF75.82FS75.66FS75.74FS 76.07FF75.74FF4%8%4%7%2%6%76.05FS76.13FFFF= 76.13PAD= 75.3Bldg. ABldg. BBldg. DBldg. CELEVATORELEVATOR6" CF76.15 FS6" CF76.15 FS6" CF76.17 FS6" CF76.20 FS6" CF76.25 FS6" CF76.25 FS2%6" CF76.25 FS3.3%6" CF76.25 FS6" CF76.25 F S 2.9%6" CF76.25 FS 2.4%76.33FF76.33FF76.33FF76.33FF76.33FF2"2"2"GARAGEGARAGEGARAGE76.50FF76.50FF76.50FF76.50FF76.33FFFF= 76.58PAD= 75.880.8FS 84.8 TW 79.5 TF 80.8TW74.8 TF80.8 TW74.8 TF86.50FS86.1FS4%86.9FS2%86.3FL/HP85.8FL2%80.3FL 82.9FL1%81.4FS88.8 TW86.8 TF88.8 TW84.8 TF84.8 TW80.8 TF82.9FS85.55FS85.55FS80.8FS79.80FS78.50FS78.30FS86.1 TW78.1 TF2%(69.77) TC(69.27) FL(5.9%)(6.0%)(68.00) TC(67.50) FL6" CF68.26 FS2%10%6" CF69.77 FS(5.8%)6" CF68.21 FL6" CF68.60 FL9.6%0.5%6" CF68.71 FL68.92 FS69.00FF68.92FS68.92FS 5%69.00FF4"GARAGE69.33FF69.33FF5%6" CF68.71 FL4"GARAGE69.33FF4"69.33FF68.92FS6" CF68.715%5%68.23FL/HP68.92FS68.92FS5%8%69.37FS 69.37 FS 69.23FS69.37FS1%69.28FS6" CF69.09 FL75.28FS69.59FS 69.59FS2%LANDSCAPELANDSCAPE6" CF69.18 FLLANDSCAPELANDSCAPELANDSCAPETRASHTRASH6" CF69.18 FS69.39 FS69.39FS7%69.47FF4"GARAGE69.80FF69.80FF7%69.84FS69.84FS69.84FS68.23FL69.8FS80.0FS82.0TG2%74.7FL83.1TW 79.1 TF 75.1 TW68.1 TF75.1 TW67.4 TF71.9 TW67.9 TF68.11FL69.91FS68.60FS1.7%68.60FS68.60FSELEVATOR68.60FS3%68.50FS68.5FS68.60FS68.60FS68.50FS68.50FS68.50FS67.6FS4%BLDG. LINEBldg. EBLDG. LINE ABOVE2%GARAGE4"GARAGE4"80.8 TW78.8TF84.7 TW83.5 BW85.5 TW80.0 BW86.1 TW80.5 BW80.0 TG 75.9 I N VDRAIN PIPE THROUGH WALLA2A2EXIST. TREE TO BE REMOVED75.9 TW69.9 TF76.5 TW74.5 TF78.5 TW73.1 TF82.4 TW81.1 TF81.1 TW73.1 TF74.4 TG69.6 INVDRAIN PIPE THROUGH WALL1%SDSDSDSDSDSDPROP. INLET AND SD (TYP)2%(6.2%)7.5% RAMP5%80.9FS2%81.4FS84.4FS7.5%84.5FS 2%67.1FS2%67.2FS75.59FSSDSDSDSDSDSDSDSDSDSDSD SD SD SD SD 6" CF 75.20 FS 6" CF75.55 FS75.1 TG73.7 INV76.4 TG75.1 INV81.7 TG75.1 INVPROP. INLET AND SD (TYP)85.5 TG74.7 INV85.5 TG74.20 INVB2B22%1.6%74.0 TG73.10 INV2%2%74.3FL 75.3 TW 72.6 TF 75.3 TW72.6 TF75.3 TW 73.3 TF75.10FS75.10FS74.8FS74.2FS74.21 TG72.6 INV69.00FF69.00FF SDSDSDSDSDSDSDSDSDFMFMFMFMFMFMSD75.08 TG72.5 INV74.98 TG73.0 INV74.8073.3INVSDSD74.80 TG74.0 INV75.5FL75.3FL/TG67.1 TG66.4 INV68.03 FL67.03 INV68.60FS2.6%EX. ST. LIGHTPROTECT IN PLACEEX. CURB, GUTTER& SIDEWALK30'20'EX. 8" SEWER MAIN PER DWG 168-10WWPROP. 2" WATER SERVICE & METERW/BACKFLOW (BLDGS C, D & E)EX. SEWER LAT.USE FOR BLDG. EPROP. SEWER LAT.FOR BLDG. A, B & DC2E2D2E2G2PROP. INLET AND SD (TYP)PRECAST CONC.INLET (TYP)PRECAST CONC.. INLET (TYP)PROP. 20' DRIVE APPROACHPER SDRSD G-14A82.1 TW80.1 TF7.5%86.4FS86.8 TW82.8 TF80.9FS76.9 TG73.8 INVSSSF67.5FSSDEX. SEWER LAT.USE FOR BLDG. CSSSSSSSSSSSSSSSSSSSSSSSWWWW W W W W W W W 67.2 TG66.5 INVSDSDSD72.8INV11' MIN.EX. WATER SERVICETO BE ABANDONEDCOVERED PARKINGCOVERED WALKWAYCOVERED PARKINGCOVERED PARKING68.6FS68.5FS68.60FS68.1FS68.0FS2%2%68.60FS68.50FS2%2.4%2.7%EX. SEWER MANHOLEWWEX. SDG&E VAULTEX. SDG&E TRANS.EX. TELE PED.EX. WALKWAYEXISTING RESIDENTIAL CONDOMINIUM BUILDINGFF = (67.3)EX. WALKWAY11.1'7.9'14.8'FMFMFMFM66.7INV24'3'24'3'5'10'4'4'5'10'1.7%68.8 TG67.8 INV69.0 TG68.2 INV69.80FF69.80FF69.47FF69.47FF69.47FF69.39FS7%69.39FS7%6" CF69.18 FL6" CF69.18 FS4%0.5%FF= 75.14PAD= 74.320'25'SD SD SD SD SD SD SD SDPROP. SEWER LATERAL& CLEANOUT (TYP)71.6INV75.55FF75.55FF75.55FF5%75.38FF75.38FF75.30FS FF= 75.63PAD= 74.9FF= 75.63PAD= 74.979.8 TG74.2 INV79.9FS 80.6 TG75.0 INV5%75.4 TG74.80 INV75.4 TG74.30 INV81.3FS81.9FS85.55FS85.5 TG75.0 INV82.8FS83.4FSSDSDSDSDSDSDSD81.2 TG74.7 INV2%PROP. INLET AND SD (TYP)86.50FS76.4 TG75.3 INV84.5FS86.50FS76.4 TG75.5 INV83.5 TG75.4 INV27.5'25'5'EX. ST. LIGHTPROTECT IN PLACEEX. UTILITY BOXESPROTECT IN PLACE78.5 TW75.2 TFSS 75.15FS75.53FS 75.45FS 75.55FS75.4 TG74.4 INV75.00FS75.20FS75.41FSLANDSCAPE75.75FS75.34FSH2H2I2I211'16'10'4'EXIST. TREE TO BE REMOVEDL3K37.6'10'4'EXIST. WATER SERVICETO BE ABANDONED81.9FS81.8FS2%2%5%1"1"1"1"1"1"FF= 76.58PAD= 75.8FF= 76.58PAD= 75.82%79.2 TG74.1 INV81.4 TG74.4 INV77.0 TG76.0 INV79.2 TG78.2 INV81.4 TG80.4 INV2'-8" RET. WALL (TYP)SDFMEX. 8" WATER MAINPER DWG 168-1010' (NTS)10' (NTS)PROP. 24' DRIVE APPROACHPER SDRSD G-14AEXIST. LOT LINETO BE REMOVED BYPARCEL MERGER75.14FF75.14FF5.77'5.77'6.29'76.13FF4%75.27FS2%2%3%3%PROP. SD PRESSURE MAINPROP. SD PRESSURE MAINTANK -1: 5426 CF DETENTION TANK67.7 BOT. ELEV. - 72.0 TOP ELEV.BF-2: 490 sf BIOFILTRATION66.17 FG INSIDE BASIN62.67 BOT. GRAVELPROP. SUMP PUMPSD67.7INVOUTFLOW MHPROP.CURB OUTLET TYPE ASDRSD D-25LANDSCAPEL.S.LANDSCAPE2%SD SD SDSD0.6%SDSD0.5%68.02 FL67.03 INV5%66.3INV66.3INVPROP. OVERFLOW INLET67.0 TG - 63.17 INVPROP. OVERFLOW INLETPROP.OVERFLOWINLETPROP. OVERFLOW INLETBF-1: 304 sf BIOFILTRATION68.44 FG INSIDE BASIN64.94 BOT. GRAVELSDSDWWPROP.OVERFLOWINLET68.5 INV75.7 TG71.9 INVBF-4: 52 sf BIOFILTRATION74.9 FG INSIDE BASIN71.4 BOT. GRAVELBF-3: 48 sf BIOFILTRATION75.7 FG INSIDE BASIN72.2 BOT. GRAVELBF-5: 48 sf BIOFILTRATION75.7 FG INSIDE BASIN72.2 BOT. GRAVELSDSDSDSDSDSDSDSDSDSDSD66.70INV/FL67.0INV67.3INVSDSDSDSDSD76.5 TG72.7 INV76.5 TG72.7 INVINLET W/ PIPE THRU WALL (TYP)PROP. 1" WATER SERVICE & METERW/BACKFLOW FOR IRRIGATIONPOC 1Q100 (MIT.)= 0.33 CFSWWLANDSCAPEPROP. 2" WATER SERVICE & METERW/BACKFLOW (BLDGS A & B)PROP. FIRE SPRINKLER SERVICEFOR BLDGS A THRU EROCK DISSIPATERAT OUTLETROCK DISSIPATERAT OUTLETM3EXIST. RET. WALLN3PROP.CURB OUTLET TYPE ASDRSD D-25PROP. BROW DITCH TYPE BSDRSD D-75 (MODIFIED)O375.4 TG74.80 INV(68.6) TW(66.8) BW(68.6) TW (67.0) BW (68.6) TW(67.2) BW(68.6) TW(67.0) BW(68.6) TW(66.8) BWSEE WALKWAYNOTE ABOVESEE WALKWAYNOTE ABOVESEE WALKWAYNOTE ABOVELANDSCAPELANDSCAPELANDSCAPELANDSCAPELANDSCAPELANDSCAPELIVICREENIGNELANOISSEFORP DE RETSIGERScale: 1"=10'Feet20100Engineering404 South Live Oak Park Road, Fallbrook, CA 92028Phone 760 731-6603E-Mail: MLBenesh@pacbell.netPrepared By:Michael L. Benesh, RCE 37893Date1/7/2020ORIGINAL SCALE:LEGEND:IMPROVEMENTSDWG. NO. **SYMBOLQUANTITYPROJECT BOUNDARYCENTER LINEEASEMENT LINEFLOW LINE SWALEDAYLIGHT LINEAC OR CONC. PAVEMENT(SECTION TO BE DETERMINED BYSOILS ENGINEER)480 SFCONC. PAVEMENT/ WALKWAYS/PATIO (MATERIALS & FINISH PERLANDSCAPE PLANS)2183 SFBIO-FILTER PLANTER942 SFUNDERGROUND DETENTION TANK(R-TANK)5,426 CFA1-6 CURBAPWA 120-240 L.F.CURB OUTLET - TYPE AD-252 EACHRETAINING WALLPER STRUCTENGINEERBUILDING RETAINING WALLPER STRUCTENGINEER-PILE & LAGGING WALLPER STRUCTENGINEERSEWER (EXISTING)SEWER (PROPOSED)STORM DRAIN (PVC SCHED 40)66 LFDROP INLET48 EACHPRECAST CONC. INLETWATER MAIN (EXISTING)WATER MAIN (PROPOSED)FIRE SPRINKLER SERVICE(PROPOSED)2" POTABLE WATER SERVICE &BACKFLOW2 EACH1" IRRIGATION WATER SERVICE &BACKFLOW1 EACH** = ALL REFERENCED STANDARD DRAWINGS ARE AS PROVIDED IN SAN DIEGO REGIONAL STANDARDDRAWINGS UNLESS OTHERWISE SPECIFIED.////CUTFILLSSSDWWFEarthwork Quantities:CUT:4,000 CYFILL:500 CYEXPORT: 3,500 CYREMEDIAL: 3,500 CYTOTAL LOT AREA = 0.858 ACRES (37375 SF)TOTAL DISTURBED AREA = 0.858 ACRES (100%)(THIS AREA INCLUDES BUT IS NOT LIMITED TO TEMPORARY DISTURBANCES SUCH AS VEHICLE AND EQUIPMENTSTAGING AREAS, CONSTRUCTION WORKER FOOT TRAFFIC, SOIL/GRAVEL PILES, UTILITY TRENCHES, BACKFILLCUTS, SLOPE KEYWAYS, AND OFF-SITE WORK INCLUDING PUBLIC IMPROVEMENTS.)TOTAL REPLACED IMPERVIOUS AREA = 0 SFTOTAL PROPOSED IMPERVIOUS AREA = 31,810 SFSee Sheet 2 for additional notes.SDP 2018-0022HDP 2018-0006ENGINEERING DEPARTMENT13PRELIMINARY GRADING PLAN FOR:RESORT VIEWVIEJO CASTILLA WAYAPNs 216-170-14 & 216-170-15PLAN DATE: 8/14/19 VIEJO CASTILLA WAYPIRINEOS WAYSiteNAVARRA DRIVESEE SHEET 3 FOR OFF-SITE TOPOSheet IndexNo. DESCRIPTION1PRELIMINARY GRADING PLAN2DETAILS & SECTIONS3DETAILS & SECTIONSSNote:All grading shall comply withrecommendations in GeoSoilsInc. report dated 2/4/19,and letters dated 8/29/19and 10/21/19 for thisproject.WALKWAY NOTE:AN ENCROACHMENT AGREEMENT IS REQUIRED FORENHANCED CONCRETE IN CITY ROW. ENGINEERING DEPARTMENT23DETAILS & SECTIONS FOR:RESORT VIEWVIEJO CASTILLA WAYAPNs 216-170-14 & 216-170-15Engineering404 South Live Oak Park Road, Fallbrook, CA 92028Phone 760 731-6603E-Mail: MLBenesh@pacbell.netPrepared By:Michael L. Benesh, RCE 37893DateLIVICREENIGNELANOISSEFORP DE RETSIGERPLAN DATE: 8/14/191/7/2020ORIGINAL SCALE:SD DETENTION TANK DETAILNOT TO SCALEPLSection DSCALE: 1"=5'PROP. BLDG. B10'EX, GRADEPLPROP. RETAINING WALLSection ESCALE: 1"=5'4'4' MAXPROP. BLDG. D10'EX, GRADESWALEEX. RETAINING WALLSection GSCALE: 1"=5'5'PROP. BLDG. EEX, GRADECOMPACTED SOIL6" DEEPC.A.B.BELOWBASIN.36"±24"6"±12" SQUARE H-20 TRAFFICRATED GRATE.JENSEN 24" SQUAREPRECAST CONC. CATCHBASIN - BACKFILLEXCAVATION W/3-SACKSAND CEMENT SLURRY30" DEPTH6" MIN.4" PVC (SCHED 80) OUTLETPIPE - CONNECT TOINFILTRATION TRENCHRISER PIPEPAVEMENTSURFACE520-C-2500 CONCRETEMATCH CURB & GUTTERDIMENSIONS520-C-2500 CONCRETEMATCH CURB & GUTTERDIMENSIONSPrecast Conc. Inlet w/H-20 Traffic Rated GrateNOT TO SCALEPER PLANCONCRETE MORTARSLOPE TO PIPE OUTLET4" PVCINLETPIPE10-1/8" DEPTHDrop Inlet DETAILNOT TO SCALECOMPACTED SOIL9-3/8" WIDTH9" SQUARE ATRIUM GRATE IN LANDSCAPING9" SQUARE FLAT GRATE IN PAVEMENT.NDS 12" SQUARE TAPEREDPOLYPROPYLENE CATCHBASIN W/ U.V. INHIBITORS.8" MIN.4" PVC (SCHED 40)INLET/OUTLET PIPESLOPESLOPE60'30'30'20'Typical Section: Viejo Castilla WayNOT TO SCALEEX. AC PAVEMENTEX. CURB & GUTTER10'10'EX. SIDEWALK20'PROJECT SITEEX. CURB & GUTTEREX. SIDEWALKCLROWROW5.5'SDP 2018-0022HDP 2018-0006 9" NDS CB INSERTMODEL 900 FFFLEXSTORM62HD12PC-SFILTER BAG &FRAME.68.6 FFEX. WALKWAY(67.3) FFEX. BLDG.11.1'3'BLDG. C & D GARAGEPROP. DRAINAGE SWALE24'BLDG. E CARPORTCONC. V-GUTTER/CURB & GUTTERVARIES - 1% MIN.A.C. DRIVEWAYSection HSCALE: 1"=5'VARIES- 2% TO 8%2.5'BLDG. D GARAGEPROP. DRAINAGE SWALE25'BLDG. B GARAGECONC. V-GUTTER/CURB & GUTTERVARIES - 2% MIN.A.C. DRIVEWAYSection ISCALE: 1"=5'VARIES- 2% TO 8%5'BLDG. C GARAGEPROP. DRAINAGE SWALE25'BLDG. A GARAGECONC. V-GUTTER/CURB & GUTTERVARIES - 2% MIN.A.C. DRIVEWAYSection JSCALE: 1"=5'VARIES- 1% TO 5%Legal Description:LOTS 35 AND 36 OF LA COSTA SOUTH UNIT NO. 1, IN THE CITY OF CARLSBAD,COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOFNO. 6117, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY.PLEX, GRADEPROP. RETAINING WALLSSection ASCALE: 1"=5'6'2'PROP. PAVEMENT5' MAX6' MAXPLPROP. RETAINING WALLSection BSCALE: 1"=5'4'CLEAR2' MAX6' MAXPROP. BLDG. A & B11.5'PLSection CSCALE: 1"=5'1'2' MAXPROP. BLDG. B11.5'SWALEEX, GRADEEX, GRADEREMEDIAL GRADINGTEMP 1:1 SLOPEPROP. PILE &LAGGING WALLREMEDIAL GRADINGTEMP 1:1 SLOPE76.05 FF BLDG A77.02 FF BLDG BRAILINGS WHENSLOPE > 5%77.02 FFPROP. WALKWAY4'MIN.REMEDIALGRADINGTEMP 1:1 SLOPEPROP. PILE &LAGGING WALLPLSHORINGREMEDIAL GRADINGTEMP 1:1 SLOPE77.02 FF76.13 FFREMEDIAL GRADINGTEMP 1:1 SLOPEPROP. WALKWAYPROP. WALKWAYVOLUME = 5,426 CF TO TOP OF OVERFLOW RISERAREA = 1,400 S.F.5' MIN.TW PER PLANTF PER PLANFS VARIES,SEE PLANFS VARIES,SEE PLAN5' MIN.3'±6'±(68.6±) TW(66.9±) BWFS PER PLANFL PER PLANFS PER PLANFS PER PLANFL PER PLANFS PER PLANFS PER PLANFL PER PLANFS PER PLANSWALETW PER PLANTF PER PLANTW PER PLANTW PER PLANTF PER PLAN3' MAX5' MIN.5' MIN.PLAN VIEWNOT TO SCALE48" DIA. MONITORING MANHOLE(JENSEN PRECAST OR EQUIV.)FINISHED GRADESECTION 1-1NOT TO SCALEPVC PIPE OUTLETOVERFLOW DRAINRISER W/ORIFICE1-1-FLOW CONTROL ORIFICE(0.4" DIA.)4.25'12" PVC OVERFLOW RISERPVC PIPE OUTLETR-TANKW/IMPERMEABLE LINERPIPE INLETS SEE GRADING PLAN4.08'FLOW CONTROL NOTCH(10" VERT X 2" HOR)PVC PIPE OUTLET48" DIA. MONITORING MANHOLE(JENSEN PRECAST OR EQUIV.)MANHOLE ACCESSR-TANKW/IMPERMEABLE LINER10'140'Biofiltration Planter DetailNOT TO SCALE6" Min.10" Ponding DepthSquare Overflow DrainSized for Q100PVC Outlet PipeTop of GrateElev. per PlanDimensions per PlanDrought Resistant Vegetation (SD-7)18" Amended SoilsMin. Inf. Rate = 5"/hr.Max. Inf. Rate = 10"/hrSee Amended SoilsComposition Table belowPipe InvertElev. per Plan3" Hardwood Mulch16" Min.Conc. Planter Wall (typ)6" Perforated PVC (SDR-35)Pipe 6" above Bottom of Basinw/Filter Sock over Pipe 67.7 BOTTOM72.0 TOPPROP. PILE &LAGGING WALLPROP. SD1' BROW DITCH TYPE BSDRSD D-75 (MODIFIED)Benchmark:DESCRIPTION: CLSB020ROD W/CAP STAMPED LS 6215 SET 220' W. ROMERIA ST. ON S. SIDE OF LA COSTA AVENUE. 5' BACK OFCURB.LOCATION:LAT 33°05'08.34848"N LONG 117°14'42.99942 WFROM THE INTERSECTION OF ROMERIA STREET AND LA COSTA AVENUE GO W. ON LA COSTA 220' TOTHE POINT ON THE LEFT. MONUMENT IS ON S. SIDE OF LA COSTA AVENUE. 5' BACK OF CURB.RECORDED: ROS 17271ELEVATION: 104.25 DATUM: NGVD 29Source of TopographyTOPOGRAPHY SHOWN ON THESE PLANS WAS GENERATED BY FIELD SURVEY METHODS FROMINFORMATION GATHERED ON FEBRUARY 20, 2018 BY MLB ENGINEERING.TOPOGRAPHY SHOWN HEREON CONFORMS TO NATIONAL MAP ACCURACY STANDARDS.Project Address:VIEJO CASTILLA WAYCARLSBAD, CA 92009Owner/Developer:BNR INVESTMENT & DEVELOPMENT, LLC23800 VIA DEL RIOYORBA LINDA, CA 92887(714) 692-9120Traffic:26 Residential UnitsAverage Daily Traffic = 6 Trips per x 26 units = 156trips per day.Water Demands: (CMWD)Average Daily Residential Demand (ADD) = 250 gallonsper day/unit x 26 units = 6500 gpd or 4.5 gpmPeak Hourly Demand = 4.5 gpm x 2.3 = 10.4 gpmLandscape Water Demand (per Landscape Plans) =81,468 gallons/year = 223 gpd Sewer Generation: (LUECADIAWASTEWATER DISTRICT)Average Daily Flows (ADF) = 220 gallons per day / unitx 26 units = 5720 gpd or 0.006 MGDPeak Daily Flows = 2.5 x 0.006 MGD = 0.015 MGDProject Location:THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBERS 216-170-14 & 15.THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT 334-16891111R-TANKVARIES3.4' TO 3.8'7.5'10'1' BROW DITCH TYPE BSDRSD D-75 (MODIFIED)2' MIN.1'BF-2EX. RET.WALL6" Washed Pea Gravel (Filter Course)15" Deep Class 2 Permeable MaterialsCALTRANS Specification 68-1.025(Storage Layer)Amended Soils CompositionBSMCompositionWashed SandCompostVolume70-85%15-30%PROP. PILE &LAGGING WALLTOP OF WALLBELOW F.G.PROP. PILE &LAGGING WALLTOP OF WALLBELOW F.G.GEOGRID 12" ABOVE R-TANK PER GEOTECHNICALENGINEER'S RECOMMENDATIONSNOTE:THE GEOTECHNICAL ENGINEER HAS RECOMMENDED THE USE OF VIBRO PIERS IN THE FOUNDATION OF THEBUILDINGS TO REDUCE REDUCE ANY POTENTIAL LOAD STRESSING OF THE DETENTION TANK SYSTEM AND TOPROTECT AGAINST THE REDUCTION IN BEARING CAPACITY OF THE SOILS IN THE EVENT THE LINER IS TORN,PUNCTURED OR DEGRADED PER LETTER DATED 10/21/19.COVER VARIES2.7' MIN.STORM DRAINSTORM DRAIN XXXN00° 03' 46"W 105.00'N00° 03' 46"W 105.00'6" C75.77 F6" CF75.80 FL7F75.90FF76.07FF2%6" CF76.17 FS6" CF76.20 FS5 FS2%76.50FF76.33FF80.8FS 84.8 TW 79.5 TF 80.8TW74.8 TF80.8 TW74.8 TF86.1FS4%86.9FS2%86.3FL/HP85.8FL2%80.3FL 82.9FL1%88.8 TW86.8 TF88.8 TW84.8 TF6" CF69.18 FS39 FS 7%69.47FF69.80FF68.23FL69.8FS80.0FS82.0TG2%74.7FL83.1TW 79.1 TF 75.1 TW68.1 TF75.1 TW67.4 TF71.9 TW67.9 TF68.60FS80.8 TW78.8TF84.7 TW83.5 BW85.5 TW80.0 BW86.1 TW80.5 BW80.0 TG 75.9 I NVA2 A2EXIST. TREE TO BE REMOVED75.9 TW69.9 TF76.5 TW74.5 TF78.5 TW73.1 TF82.4 TW81.1 TF81.1 TW73.1 TF74.4 TG69.6 INV1%PROP. INLET AND SD (TYP)2%2E2D2E26.4FS10'4'4'4%86.50FSEXISTING RESIDENTIAL CONDOMINIUM BUILDINGFF = (78.0)EXISTING RESIDENTIAL CONDOMINIUM BUILDINGFF = (81.0)11'16'10'4'EXIST. TREE TO BE REMOVEDK310'4'LAEXIST. RET. WALLLIVICREENIGNELANOISSEFORP DERETSIGERScale: 1"=10'Feet20100Engineering404 South Live Oak Park Road, Fallbrook, CA 92028Phone 760 731-6603E-Mail: MLBenesh@pacbell.netPrepared By:Michael L. Benesh, RCE 37893Date1/7/2020ORIGINAL SCALE:SEE SHEET 1 FOR GRADING PLANOFF-SITE TOPOSCALE: 1"=10'PLEX. RETAINING WALLSection LSCALE: 1"=10'5'EX, GRADE68.6 FFEX. WALKWAYBF-2(67.3) FFEX. BLDG.11.1'PL3'-4" WALLEX, GRADEBUILDING ETRASH ENC.DRIVEWAYDRIVEWAY81.6 TWPROP. WALKWAYSection KSCALE: 1"=10'PLPL(81.0) FFEX. RETAINING WALLEX. BLDG.BUILDING DBUILDING C5'-4" WALLEX, GRADEPROP. WALKWAYPROP. WALKWAY2' WALLVIEJO CASTILLA WAYENGINEERING DEPARTMENT33DETAILS & SECTIONS FOR:RESORT VIEWVIEJO CASTILLA WAYAPNs 216-170-14 & 216-170-15PLAN DATE: 8/14/1968.2 FL69.59 FS76.1 TC69.12 FL75.15 FL2'-8" WALL2'-8" WALL2'-8" WALL79.4 TW77.2 TW82.3 FS85908075706585908075706576.0 FS76.0 FS75.0 FS75.0 FS(73.1) TCSection MSCALE: 1"=5'PROP. BLDG. C8'1.6'±'1.2'±VIEJO CASTILLA WAY2' MIN.BF-1Section NSCALE: 1"=5'PROP. BLDG. B17.5'3.33'2' MIN.BF-53.33'4'BF-32' MIN.PROP. BLDG. APLSection OSCALE: 1"=5'4'CLEAR1'2' MAXPROP. BLDG. A & B11.5'EX, GRADEPROP. PILE &LAGGING WALLREMEDIAL GRADING76.05 FF BLDG A77.02 FF BLDG BRAILINGS WHENSLOPE > 5%PROP. WALKWAY1' BROW DITCH TYPE BSDRSD D-75 (MODIFIED)TW VARIESMIN. 6" ABOVE FG0.25' MIN.2% ±2% ±75.5 FGR-TANKPLPL6"3" CONCRETEFORM CONCRETEAROUND PILINGWHERE OCCURS.Modified D-75 DrainSCALE: 1"=2'Q100 = 0.1 cfsDn = 0.13'Slope = 2% Min.9"STORM DRAIN ^dW^ϭ;ƐŚƌƵďĚƌŝƉͿϮ;ƐŚƌƵďĚƌŝƉͿϯ;&ŽƵŶƚĂŝŶͿϰ;ƐLJŶ͘ƚƵƌĨͿϱ;ƉĂůŵͿϲ^>ƚŽϭŽŶǀĞƌƐŝŽŶ&ĂĐƚŽƌ Ϯ;ƐƚĞƉϭdžƐƚĞƉϮͿ ϯtƵůĐŽůƐ;W&Ϳ ϰ Ϭ͘ϯ Ϭ͘ϱ Ϭ͘ϴ Ϭ Ϭ͘ϱ Ϭ ,LJĚƌŽͲnjŽŶĞĂƌĞĂƐĨ;,Ϳϱ ϭϰϬϱ ϯϲϬϱ ϱϭ ϭϱϭ ϭϰϯ Ϭ Ϭ;ƐƚĞƉϰdžƐƚĞƉϱͿ ϲ ϰϮϮ ϭϴϬϯ ϰϭ Ϭ ϳϮ Ϭ /ƌƌĨĨŝĐŝĞŶĐLJ;/Ϳ ϳ Ϭ͘ϴ Ϭ͘ϴ Ϭ͘ϴ Ϭ͘ϴ Ϭ͘ϴ Ϭ ;ƐƚĞƉϲͬƐƚĞƉϳͿ ϴ ϱϮϳ ϮϮϱϯ ϱϭ Ϭ ϴϵ Ϭ ;ƚŽƚĂůĂůůƐƚĞƉϴнƚŽƚĂů^>ƐĨŝŶƐƚĞƉϱͿϵ;ƐƚĞƉϯdžƐƚĞƉϵͿdthŝŶŐĂůͬLJƌͲdŽƚĂůƐŚĂůůŶŽƚĞdžĐĞĞĚDtϭϬϰϳϮϵ͘ϭϬ͘ϲϮϮϵϮϬϴϱ͕ϭϬϬŚLJĚƌŽnjŽŶĞŶƵŵďĞƌϭͲϰǁͬ^>njŽŶĞ/dzK&Z>^^d/DddKd>tdZh^;dthͿ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rom:Cliff Jones To:Melissa Flores Subject:FW: NOTICE: SDP-2018-0022/HDP-2018-0006(Dev-2017-0225) Date:Tuesday, February 04, 2020 2:51:22 PM Resort View public comment. Sincerely, Cliff Jones Senior Planner Community Development Department City of Carlsbad 1635 Faraday Ave. Carlsbad, CA 92008 www.carlsbadca.gov 760-602-4613 | Cliff.Jones@carlsbadca.gov Appointment-Based Submittals and Resubmittals Appointments can be made by phone or email: Phone: 760-602-2723 Email: devappt@carlsbadca.gov Facebook | Twitter | You Tube | Flickr | Pinterest | Enews From: Matt Kurlan <> Sent: Sunday, February 2, 2020 2:51 PM To: Cliff Jones <Cliff.Jones@carlsbadca.gov> Subject: NOTICE: SDP-2018-0022/HDP-2018-0006(Dev-2017-0225) Dear Mr. Jones, I believe the original prospectus for this project described a 2-story building. But I am vehemently opposed to the proposed 4-story building to be built directly across the streetfrom our own condo. The name, "Resort View Apts.", seems misplaced considering that, as the tallest building in La Costa, it would be obstructing views from all the neighboring residences! Furthermore, a 4- story building does not fit with the golf course/ country club "feel" of La Costa, so it wouldhave a negative impact on both the spirit & investment value of the area. A project of this density does not belong in La Costa. I believe the developer should reset their goals to a 2-story building. They should not be allowed to pursue their own profits at theexpense of the existing community. Sincerely, Matt Kurlan Carlsbad, CA 92009 CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.   February 4, 2020    City of Carlsbad  Planning Commission     Re: Resort View Apartments    Dear Planning Commission, and City Attorney,     The California Renters Legal Advocacy and Education Fund (CaRLA)submits this            letter to inform the Planning Commission that they have an obligation to abide by all                relevant state housing laws when evaluating the site development plan and hillside             development permits for the Resort View Apartment proposal,including the Housing            Accountability Act GOV 65589.5,which requires approval of zoning and general plan             compliant projects unless findings can be made regarding specific,objective,written health             and safety hazards.  As you are well aware,California remains in the throes of a statewide crisis-level               housing shortage.New housing such as this is a public benefit;it will bring increased tax                 revenue,new customers to local businesses,decarbonization in the face of climate crisis,              but most importantly it will reduce displacement of existing residents into homelessness or              carbon-heavy car commutes.This development will also bring much needed affordable            housing to Carlsbad without any need for public subsidy,though the city’s inclusionary              housing program. We urge the Planning Commission to approve this proposal.   CaRLA is a 501(c)3 non-profit corporation whose mission includes advocating for            increased access to housing for Californians at all income levels,including low-income             households.While no one project will solve the regional housing crisis,the proposed Resort               View Apartments development is the kind of housing Carlsbad needs to mitigate             displacement,provide shelter for its growing population,and arrest unsustainable housing            price appreciation. You may learn more about CaRLA at​ www.carlaef.org​.    Sincerely,    Dylan Casey  Executive Director  California Renters Legal Advocacy and Education Fund      Yes In My Back Yard  1260 Mission St  San Francisco, CA 94103  hello@yimbylaw.org     2/4/2020    Carlsbad Planning Commission  City Council Chamber  1200 Carlsbad Village Drive  Carlsbad, CA 92008    planning@carlsbadca.gov​; ​clerk@carlsbadca.gov​;   Via Email      Re: Resort View Apartments  SDP 2018-0022    Dear Carlsbad Planning Commission,    Yes In My Back Yard submits this letter to inform you that the Carlsbad Planning Commission                 has an obligation to abide by all relevant state housing laws when evaluating the above                captioned proposal, including the Housing Accountability Act (HAA).     California Government Code § 65589.5, the Housing Accountability Act, prohibits localities  from denying housing development projects that are compliant with the locality’s zoning  ordinance or general plan at the time the application was deemed complete, unless the locality  can make findings that the proposed housing development would be a threat to public health  and safety. The most relevant section is copied below:    (j)When a proposed housing development project complies with applicable,objective general plan              and zoning standards and criteria,including design review standards,in effect at the time that the                 housing development project's application is determined to be complete,but the local agency              proposes to disapprove the project or to approve it upon the condition that the project be developed                  at a lower density,the local agency shall base its decision regarding the proposed housing                development project upon written findings supported by substantial evidence on the record that              both of the following conditions exist:    (1)The housing development project would have a specific,adverse impact upon the public               health or safety unless the project is disapproved or approved upon the condition that the                project be developed at a lower density.As used in this paragraph,a "specific,adverse                impact"means a significant,quantifiable,direct,and unavoidable impact,based on            objective,identified written public health or safety standards,policies,or conditions as they              existed on the date the application was deemed complete.    (2)There is no feasible method to satisfactorily mitigate or avoid the adverse impact               identified pursuant to paragraph (1),other than the disapproval of the housing development              project or the approval of the project upon the condition that it be developed at a lower                  density.    . . .        (4)For purposes of this section,a proposed housing development projectis not inconsistent               with the applicable zoning standards and criteria,and shall not require a rezoning,if the                housing development project is consistent with the objective general plan standards and             criteria but the zoning for the project site is inconsistent with the general plan.If the local                  agency has complied with paragraph (2),the local agencymay require the proposed housing               development project to comply with the objective standards and criteria ofthe zoning which               is consistent with the general plan,however,the standards and criteria shall be applied to                facilitate and accommodate development at the density allowed on the site by the general               plan and proposed by the proposed housing development project.    The applicant proposes the construction of a 26-unit residential apartment project consisting             of three, three-story buildings and two, four-story buildings.    The above captioned proposal is zoning compliant and general plan compliant,therefore,your              local agency must approve the application,or else make findings to the effect that the                proposed project would have an adverse impact on public health and safety,as described               above.    Yes In My Back Yard is a 501(c)3 non-profit corporation,whose mission is to increase the                 accessibility and affordability of housing in California.    I am signing this letter both in my capacity as the Executive Director of Yes In My Back Yard,                    and as a resident of California who is affected by the shortage of housing in our state.     Sincerely,      Sonja Trauss  Executive Director  Yes In My Back Yard    YIMBY Law, 1260 Mission St, San Francisco, CA 94103  From:Cynthia Molina To:Planning Subject:Resort View Appartments Date:Wednesday, February 05, 2020 10:52:53 AM RE: NOTICE: SDP-2018-0022/HDP-2018-0006(Dev-2017-0225) "Resort View Apts." Attention Cliff Jones, I am a resident of Carlsbad and live on VIEJO CASTILLA WAY for 21 years and currently we face parking issues on a daily basis .Some days there is not one parking spot on VIEJO CASTILLA WAY There are so many condos homes on this street and Narava. In the event of a fire there is only one way out up to La Costa Ave majordisaster because and so many people live in this small area.. If this Appartments are built not only will we create even more parking problems but it will block our view to the golf course and take equity value away from our property current value ..I ask the city to evaluate come and count the amount of cars trucks onour streets It is constant noise Trash trucks coming all hours of the day and night I think every Condominium property is on a different day for pick up .Over the years this place has become unbearable in noise level there are to many people in a small area This will definitely devalue our property value in La Costa.Please consider what I have to say and please do not allow four stories it will completely block our beautiful views of our La Costa Golf Coarse Thank you for you time in reading this matter Cynthia Molina Board Treasurer Flave LaCosta Condominium Homeowners Association Sent from Yahoo Mail on Android CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.