Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutCD 2019-0015; T-MOBILE CARLSBAD INN; Consistency Determination■ ■ ■ ■
SIT_E NUMBER:
SITE NAME:
SITE TYPE:
SD06298A {L 1900/L600)
CARLSBAD INN
ROOFTOP
SITE ADDRESS:
3001 CARLSBAD BLVD.
CARLSBAD, CA 92008
PROPERTY OWNER:
CARLSBAD INN LTD
3001 CARLSBAD BLVD.
CARLSBAD, CA 92008
CONTACT: LEONARD BARON
PHONE: (619) 434-7542
APPLICANT:
T-MOBILE WEST CORPORATION
LATITUDE & LONGITUDE (NAD83):
33. 157000. (N 33° 09' 25.2")
-117.351111" (W -117° 21' 04.0")
PROPERTY INFORMATION:
OCCUPANCY CLASSIFICATION
TYPE OF CONSTRUCTION:
ZONING:
ASSESSORS PARCEL NUMBER:
B-2
V-NON RATED
C-1-Q
203-252-04
10509 VISTA SORRENTO PKWY, SUITE 206
SAN DIEGO, CA 92121
PROJECT DESCRIPTION -RFDS L600 V2.1:
THIS PROJECT INCLUDES THE MODIFICATIONS TO AN EXISTING T-MOBILE
WIRELESS FACILITY, INCLUDING:
• RELOCATE (3) (E) 56" AIR21 PANEL ANTENNAS (1 PER SECTOR)
• REMOVE (3) EXISTING 56" AIR21 PANEL ANTENNAS (1 PER SECTOR)
• REMOVE (3) EXISTING TMA (1 PER SECTOR)
• INSTALL (3) NEW 56" AIR32 PANEL ANTENNAS (1 PER SECTOR)
• INSTALL (3) NEW 48" FFHH PANEL ANTENNAS (1 PER SECTOR)
• INSTALL (3) NEW RADIO 4449 B71+812 AT ANTENNA (1 PER SECTOR)
• ADD (2) NEW 8B6630
• ADD ( 1 2) DC POWER & ( 18) FIBER CABLES
• UPDATE A/C BREAKER AND WIRING AS REQUIRED
SAC/ZONING/PERMITTING:
INFINIGY
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CA 92630
CONTACT: NIC FAURE
PHONE: (714) 566-4451
ARCHITECTURAL & ENGINEERING:
INFINIGY ENGINEERING LLP
26455 RANCHO PKWY SOUTH
LAKE FOREST, CA 92630
CONTACT: DAN CONNELL
PHONE: (949) 306-4644
--------~ ----~------------------
SHEET NUMBER:
T-1
T-2
A-1
A-2
A-3
A-3.1
A-3.2
A-4
A-5
SHEET INDEX:
DESCRIPTION:
TITLE SHEET
ABBREVIATIONS, SYMBOLS, GENERAL NOTES & SPECIFICATIONS
SITE PLAN & ENLARGED SITE PLAN
ANTENNA SCHEDULE, (E) & (N) ANTENNA LAYOUTS
ARCHITECTURAL ELEVATIONS
ARCHITECTURAL ELEVATIONS
ARCHITECTURAL ELEVATIONS
ARCHITECTURAL DETAILS
PLUMBING DIAGRAM
APPROVALS:
THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND
AUTHORIZE THE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN.
ALL CONSTRUCTION DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING
DEPARTMENT AND ANY CHANGES AND MODIFICATIONS THEY MAY IMPOSE.
PRINT NAME SIGNATURE DATE
LANDLORD
DEVELOP. MGR _____ _
CONST. MGR
ZONING MGR
RF ENGINEER
OPERATIONS
SAC REP.
UTILITIES
•
® ■
CITY:
COUNTY:
CARLSBAD
SAN DIEGO
ZONING: CITY OF CARLSBAD
DIRECTIONS FROM T-MOBILE SAN DIEGO OFFICE:
1. TURN LEFT ONTO VISTA SORRENTO PKWY.
2. TURN RIGHT ONTO NORTH 805 FWY.
3. CONTINUE ONTO NORTH 5 FWY.
4. TAKE EXIT 50 FOR CARLSBAD VILLAGE DR.
5. TURN LEFT ONTO CARLSBAD BLVD.
6. DESTINATION ON THE RIGHT
BUILDING CODE REFERNCE:
VICINITY MAP:
CARLSBAD.
Lai)dt;rlfl!'k S\g11
v >
DRIVING DIRECTIONS:
Board & Breit/ -
CarlSbnd· V:{1 l
CONSISTENCY DETERMINATION EXHIBIT
FORORIGJNALPROJEcrNo. 'RP~7-o~A
Q .:JJ; Cb ZOICf-:!r" 8"/J<f1(9i l.
Don Neu. Cizy PlaIUiet . ; )
RECOMMENDEDBY: £$tebQ.i. Pe:lltl"'--
DATE: "a/i,;; h,
APPLICABLE CODES
• ALL WORK IS TO COMPLY WITH THE 2016 CALIFORNIA BUILDING CODE (CBC)
• ANSI/TIA-222-G
• 607 COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS
• AISC -CONSTRUCTION MANUAL, 9TH EDITION OR LATER.
• CEC (CALIFORNIA ELECTRICAL CODE) 201 6
• CFC (CALIFORNIA FIRE CODE) 2016 -2015 IFC
.
Qr -i c--.... ,,, .. iu·1-"1 :V.V l;..,' . .._,
rp · ·Mobile·
PLANS PREPARED BY:----------
INFINIGY8
. ENGINEERING, LLP
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB NUMBER: 581-100
CONSULTING GROUP:----------
NO. DATE: DESCRIPTION: BY:
0 05/14/19 90% CD'S JG
1 05/24/19 100% CD'S CAM
2 06/19/19 100% CD'S CAM
3 08/05/19 ZAP COMMENTS CAM
SITE INFORMATION: -------------.
CARLSBAD INN
SD06298A
3001 CARLSBAD BLVD.
CARLSBAD, CA 92008
SEAL:---------------
AUG O 7 2019
C+= .:=:A?..~SB.21.:J
.,:·,~ i·-!G O;\/lS!C.YN
SHEET TITLE:------------
TITLE SHEET.
SHEET NUMBER:-----------
T-1
.
(
ABBREVIATIONS
AB ANCHOR BOLT LAM
AC ASPHALTIC CONCRETE LBS AbC AIR CONDITIONING LT
A J ADJUSTABLE LA
A.F.F. ABOVE FINISH FLOOR LNA
ARCH ARCHITECTURAL
APPROX APPROXIMATELY MFR
A.G.L. ABOVE GRADE LEVEL MAT
A.M.S.L. ABOVE MEAN SEA LEVEL MAX
MECH
BD BOARD MIN
BLDG BUILDING MISC
BLKG BLOCKING ML
BOT BOTTOM MO
BSMT BASEMENT MS
BTS BASE TRANSCEIVER MTD
STATION MTL
C COURSE(S) fu~~ CEM CEMENT
CL CHAIN LINK NO
CLG CEILING NTS
CLR CLEAR
COL COLUMN OA
CONC CONCRETE O.C.
CONST CONSTRUCTION OPNG
CONT CONTINUOUS OPP
CORR CORRIDOR co CONDUIT ONLY PARTN
PL
PLAS
DIA DIAMETER PLYWD
DBL DOUBLE POC
DEPT DEPARTMENT PROP
DEMO DEMOLITION PT
DIM DIMENSION
DN DOWN R
DR DOOR REQD
DTL DETAIL RD
DWG DRAWING RM
RMS
~ EXISTING RO
EACH
ELEC ELECTRIC SC
ELEV ELEVATION SCHED
EQUIP EQUIPMENT SECT
EXP EXPANSION SHT
EXT EXTERIOR SIM
SPECS
FA FIRE ALARM ss
FB FLAT BAR STL
FF FINISH FLOOR STOR
FH FLAT HEAD STRUCT
FIN FINISH(ED) SUSP
FLR FLOOR SW
FOS FACE OF STUDS SWBO
FS FINISH SURFACE THK FT FOOT, FEET
FTG FOOTING Tl
FW FINISH WALL TMA
F.G. FINISH GRADE TOS
FUT FUTURE TS
TYP
GA GAUGE UNO GALV GALVANIZED
GL GLASS
GR GRADE VCT
GYP GYPSUM
GFCI GROUND FAULT CIRCUIT
INTERRUPT VERT
GND GROUND V.I.F.
VG
HC HOLLOW CORE
HDW HARDWARE ~ti HTR HEATER
HM HOLLOW METAL ·• WR
HORIZ HORIZONTAL WT
HR HOUR
HT HEIGHT XFMR
HV HIGH VOLTAGE
@
ID INSIDE DIMENSION [ INS INSULATION
INT INTERIOR ct
L.
JT JOINT ft
SYMBOLS:
A
/ X "',.
SECTION NUMBER
SHEET NUMBER
rxX DETAIL NUMBER
~ SHEET NUMBER
SECTION NUMBER
SHEET NUMBER
~ DETAIL NUMBER
~ SHEET NUMBER
KEY NOTE REFERENCE
I
I
LAMINATED
POUNDS
LIGHT
LIGHTNING ARRESTOR
LOW NOISE AMPLIFIER
MANUFACTURER
MATERIAL
MAXIMUM
MECHANICAL
MINIMUM
MISCELLANEOUS
METAL LATH
MASONRY OPENING
MACHINE SCREW
MOUNTED
METAL
NEW
NOT IN CONTRACT
NUMBER
NOT TO SCALE
OVERALL
ON CENTER
OPENING
OPPOSITE
PARTITION
PLATE
PLASTER
PLYWOOD
POINT OF CONNECTION
PROPERTY
PRESSURE TREATED
RISER
REQUIRED
ROOF DRAIN
ROOM
ROOMS
ROUGH OPENING
SOLID CORE
SCHEDULE
SECTION
SHEET
SIMILAR
SPECIFICATIONS
STAINLESS STEEL
STEEL
STORAGE
STRUCTURAL
SUSPENDED
SWITCH
SWITCHBOARD
THICK
TENANT IMPROVEMENT
TOWER MOUNTED AMPLIFIER
TOP OF SURFACE
TUBE STEEL
TYPICAL
UNLESS NOTED
OTHERWISE
VINYL
COMPOSITION
TILE
VERTICAL
VERIFY IN FIELD
VERTICAL GRAIN
WITH
WOOD
WATER RESISTANT
WEIGHT·
TRANSFORMER
AT
CHANNEL
CENTERLINE
ANGLE
PROPERTY LINE
BUILDING SECTION
REFERENCE
DETAIL REFERENCE
DETAIL SECTION
REFERENCE
EXTERIOR ELEVATION
REFERENCE
CD ----------PROPERTY LINE
X ) DOOR NUMBER )( )( )( FENCING
I X I AREA AND/OR ROOM NUMBER -E-E-E-E-ELECTRICAL SERVICE
ffi MECHANICAL UNIT -T-T-T-T-TELCO SERVICE
ABBREVIATIONS & SYMBOLS SCALE:
N.T.S. 1
-------T
GENERAL
1. THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS.
2. THE CONTRACTOR SHALL NOTIFY ARCHITECT/ENGINEER OF ANY ERRORS,
OMISSIONS, OR DISCREPANCIES AS THEY MAY BE DISCOVERED IN THE PLANS,
SPECIFICATIONS, & NOTES PRIOR TO STARTING CONSTRUCTION. INCLUDING BUT NOT
LIMITED BY DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING
ANY ERRORS, OMISSION, OR INCONSISTENCY AFTER THE START OF CONSTRUCTION
WHICH HAS NOT BEEN BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER
AND SHALL INCUR ANY EXPENSES TO RECTIFY THE SITUATION. THE METHOD OF
CORRECTION SHALL BE APPROVED BY THE ARCHITECT/ENGINEER.
3. PRIOR TO STARTING CONSTRUCTION THE CONTRACTOR HAS THE RESPONSIBILITY
TO LOCATE ALL EXISTING UTILITIES, WHETHER OR NOT SHOWN ON THE PLANS, AND
TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR OR SUBCONTRACTOR SHALL
BEAR THE EXPENSE OF REPAIRING OR REPLACING ANY DAMAGE TO THE UTILITIES
CAUSED DURING THE EXECUTION OF THE WORK.
4. A COPY OF THE APPROVED PLANS SHALL BE KEPT IN A PLACE SPECIFIED BY
THE GOVERNING AGENCY, AND BY LAW SHALL BE AVAILABLE FOR INSPECTION AT ALL
TIMES. IT IS THE CONTRACTORS RESPONSIBILITY TO ENSURE ALL CONSTRUCTION
SETS REFLECT THE SAME INFORMATION AS THE APPROVED PLANS. THE CONTRACTOR
SHALL ALSO MAINTAIN ONE SET OF PLANS AT THE SITE FOR THE PURPOSE OF
DOCUMENTING ALL AS-BUILT CHANGES, REVISIONS, ADDENDUM'S, OR CHANGE
ORDERS. THE CONTRACTOR SHALL FORWARD THE AS-BUILT DRAWINGS TO THE
ARCHITECT/ENGINEER AT THE CONCLUSION OF THE PROJECT.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE
SITE FROM START OF PROJECT TO COMPLETION OF PROJECT.
6. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE TEMPORARY POWER, WATER, AND
TOILET FACILITIES.
7. ALL CONSTRUCTION THC<OUGH THE PROJECT SHALL CONFORM TO THE 2016 CBC
AND ALL OTHER GOVERNING CODES.
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY
PRECAUTIONS AND REGULATIONS DURING THE WORK. THE ENGINEER WILL NOT
ADVISE ON NOR PROVIDE DIRECTION AS TO SAFETY PRECAUTIONS AND PROGRAMS.
9. THE CONTRACTOR SHALL SUPERVISE AND COORDINATE ALL WORK, USING HIS
PROFESSIONAL KNOWLEDGE AND SKILLS. HE IS SOLELY RESPONSIBLE FOR ALL
CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES AND SEQUENCING AND
COORDINATING ALL PORTIONS OF THE WORK.
10. THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN AND PAY FOR ALL
PERMITS, LICENSES AND INSPECTIONS WITH RESPECT TO THE WORK TO COMPLETE
THE PROJECT. BUILDING PERMIT APPLICATIONS SHALL BE FILED BY THE OWNER OR
HIS REPRESENTATIVE. CONTRACTOR SHALL OBTAIN THE PERMIT AND MAKE FINAL
PAYMENT OF SAID DOCUMENT.
11. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALE UNLESS OTHERWISE NOTED.
12. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING, BACKING,
FRAMING, HANGERS OR SUPPORTS FOR INSTALLATION OF ITEMS INDICATED ON THE
DRAWINGS.
13. THE CONTRACTOR SHALL PROVIDE THE FIRE MARSHALL APPROVED MATERIALS TO
FILL/SEAL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES.
14. NEW CONSTRUCTION ADDED TO EXISTING CONSTRUCTION SHALL BE MATCHED IN
FORM, TEXTURE, MATERIAL AND PAINT COLOR EXCEPT AS NOTED IN THE PLANS.
15. WHERE SPECIFIED, MATERIALS TESTING SHALL BE TO THE LATEST STANDARDS
AVAILABLE AS REQUIRED BY THE LOCAL GOVERNING AGENCY RESPONSIBLE FOR
RECORDING THE RESULTS.
16. ALL GENERAL NOTES AND STANDARD DETAILS ARE THE MINIMUM REQUIREMENTS
TO BE USED IN CONDITIONS WHICH ARE NOT SPECIFICALLY SHOWN OTHERWISE.
17. ALL DEBRIS AND REFUGE IS TO BE REMOVED FROM THE PROJECT DAILY.
PREMISES SHALL B~ LEFT IN A CLEAN BROOM FINISHED CONDITION AT ALL TIMES.
18. ALL SYMBOLS AND ABBREVIATIONS ARE CONSIDERED CONSTRUCTION INDUSTRY
STANDARDS. IF A CONTRACTOR HAS A QUESTION REGARDING THEIR EXACT MEANING
THE ARCHITECT/ENGINEER SHALL BE NOTIFIED FOR CLARIFICATIONS
19. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE METHODS, TECHNIQUES
AND SEQUENCES OF PROCEDURES TO PERFORM THE WORK. THE SUPERVISION OF
THE WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
20. CONTRACTORS SHALL VISIT THE SITE PRIOR TO BID TO ASCERTAIN CONDITIONS
WHICH MAY ADVERSELY AFFECT THE WORK OR COST THEREOF.
21 THE CONTRACTOR SHALL FIELD VERIFY THE DIMENSION, ELEVATION, ETC.
NECESSARY FOR THE PROPER CONSTRUCTION AND ALIGNMENT OF THE NEW PORTION
OF THE WORK TO THE EXISTING WORK. THE CONTRACTOR SHALL MAKE ALL
MEASUREMENTS NECESSARY FOR FABRICATION AND ERECTION OF STRUCTURAL
MEMBERS. AND DISCREPANCY SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION
OF THE ARCHITECT/ ENGINEER.
22. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES
WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES, AND
WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE
RELOCATED AS DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE USED BY
THE CONTRACTOR WHEN EXCAVATING OR PIER DRILLING AROUND OR NEAR UTILITIES.
23. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES,
WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND
SHALL BE CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL
NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL
OF THE ENGINEER.
24. NO CHANGES ARE TO BE MADE TO THESE PLANS WITHOUT THE KNOWLEDGE
AND WRITTEN CONSENT OF THE ARCHITECT/ ENGINEER. UNAUTHORIZED CHANGES
RENDER THESE DRAWINGS VOID.
25. ANY REFERENCE TO THE WORDS APPROVED, OR APPROVAL IN THESE
DOCUMENTS SHALL BE HERE DEFINED TO MEAN GENERAL ACCEPTANCE OR REVIEW
AND SHALL NOT RELIEVE THE CONTRACTOR AND/OR HIS SUB-CONTRACTORS OF
ANY LIABILITY IN FURNISHING THE REQUIRED MATERIALS OR LABOR SPECIFIED.
26. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL
EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT, AND TO PROTECT THEM
FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR
REPLACEMENT IN CONJUNCTION WITH THE EXECUTION OF THIS WORK. 10. GENERAL
CONTRACTOR SHALL NOTIFY THE ENGINEER AND ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES FOUND WITHIN THE CONTRACT DOCUMENTS, PRIOR TO STARTING
WORK.
GENERAL NOTES & SPECIFICATIONS
SITE PREPARATION NOTES:
1. THE PREPARATION OF THE SITE FOR CONSTRUCTION SHALL INCLUDE THE
REMOVAL OF ALL BROKEN CONCRETE, TREE TRUNKS AND ANY OTHER DEBRIS THAT
WOULD BE DAMAGING TO THE FOOTINGS OF THE NEW STRUCTURE.
2. BACK FILLING AT TRENCHES SHALL BE OF CLEAN, STERILE SOIL HAVING A SAND
EQUIVALENT OF 30 OR GREATER. BACK FILLING SHALL BE DONE IN 8 INCH LAYERS,
MOISTURE CONDiTIONED AND PROPERLY COMPACTED. ADEQUATE DRAINAGE SHALL BE
PROVIDED SUCH THAT NO PONDING OCCURS.
3. ALL FOUNDATION FOOTINGS SHALL EXTEND INTO AND BEAR AGAINST NATURAL
UNDISTURBED SOIL OR APPROVED COMPACTED FILL. FOOTINGS SHALL EXTEND INTO
SOIL DEPTH AS INDICATED IN PLANS.
4. SHOULD ANY LOOSE FILL, EXPANSIVE SOIL, GROUND WATER OR ANY OTHER
UNEXPECTED CONDITIONS BE ENCOUNTERED DURING THE EXCAVATION FOR THE NEW
FOUNDATION, THE ARCHITECT/ENGINEER SHALL BE NOTIFIED AND ALL FOUNDATION
WORK SHALL CEASE IMMEDIATELY.
5. WITHIN AN AREA A MINIMUM OF 5 FEET BEYOND THE BUILDING LIMITS, EXCAVATE
A MINIMUM OF 4" OF EXISTING SOIL. REMOVE ALL ORGANICS, PAVEMENT, ROOTS,
DEBRIS AND OTHERWISE UNSUITABLE MATERIAL.
6. THE SURFACE OF THE EXPOSED SUBGRADE SHALL BE INSPECTED BY PROBING
OR TESTING TO CHECK FOR POCKETS OF SOFT OR UNSUITABLE MATERIAL. EXCAVATE
UNSUITABLE SOIL AS DIRECTED BY THE GEOTECHNICAL ENGINEER/TESTING AGENCY.
7. PROOFROLL THE SURFACE OF THE EXPOSED SUBGRADE WITH A LOADED TANDEM
AXLE DUMP TRUCK. REMOVE ALL SOILS WHICH PUMP OR DO NOT COMPACT
PROPERLY AS DIRECTED BY THE GEOTECHNICAL ENGINEER/TESTING AGENCY.
8. FILL ALL EXCAVATED AREAS WITH APPROVED CONTROLLED FILL. PLACE IN S"
LOOSE LIFTS AND THE MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM 0-698.
COMPACT TO A MINIMUM OF 90% RELATIVE COMPACTION
9. THE STRUCTURAL DRAWINGS HERE IN REPRESENT THE FINISHED STRUCTURE. THE
CONTRACTOR SHALL PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO
ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL
WORK AND CONNECTIONS HAVE BEEN COMPLETED. THE INVESTIGATION, DESIGN,
SAFETY, ADEQUACY AND INSPECTION OF ERECTION BRACING, SHORING, TEMPORARY
SUPPORTS, ETC. IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
1 0. PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR SHALL PROTECT ALL
AREAS FROM DAMAGE WHICH MAY OCCUR DURING CONSTRUCTION. ANY DAMAGE TO
NEW OR EXISTING SURFACES, STRUCTURES OR EQUIPMENT SHALL BE IMMEDIATELY
REPAIRED OR REPLACED TO THE SATISFACTION OF THE PROPERTY OWNER. THE
CONTRACTOR SHALL BEAR THE EXPENSE OF REPAIRING OR REPLACING ANY DAMAGED
AREAS.
11. WHEN REQUIRED STORAGE OF MATERIALS OCCURS, THEY SHALL BE EVENLY
DISTRIBUTED OVER THE FLOOR OR ROOF SO AS NOT TO EXCEED THE DESIGNED
LIVE LOADS FOR THE STRUCTURE. TEMPORARY SHORING OR BRACING SHALL BE
PROVIDED WHERE THE STRUCTURE OR SOIL HAS NOT ATTAINED THE DESIGN
STRENGTH FOR THE CONDITIONS PRESENT.
12. BEFORE PROCEEDING WITH ANY WORK WITHIN THE EXISTING FACILITY, THE
CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH EXISTiNG STRUCTURAL AND OTHER
CONDITIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL
NECESSARY BRACING, SHORING AND OTHER SAFEGUARDS TO MAINTAIN Al.L PARTS OF
THE EXISTING WORK IN A SAFE CONDITION DURING THE PROCESS OF DEMOLITiON
AND CONSTRUCTION AND TO PROTECT FROM DAMAGE THOSE PORTIONS OF THE
EXISTING WORK WHICH ARE TO REMAIN.
SUBMITTALS:
SUBMITTALS: SUBMITTALS FOR SHOP DRAWINGS, MILL TESTS, PRODUCT DATA, ETC.
FOR ITEMS DESIGNED BY THE ARCHITECT/ ENGINEER OF RECORD SHALL BE MADE
TO THE ARCHITECT/ENGINEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL
REViEW THE SUBMITTAL BEFORE FORWARDING TO THE ARCHITECT. SUBMITTALS SHALL
BE MADE IN ADVANCED TO ARCHITECT-ENGINEER. SUBMITTALS REQUIRED FOR EACH
SECTION OF THESE NOTES ARE SPECIFIED IN THAT SECTION.
SHOP DRAWING REVIEW:
REVIEW BY THE ARCHITECT /ENGINEER IS FOR GENERAL COMPLIANCE WITH THE
DESIGN CONCEPT AND THE CONTRACT DOCUMENTS. MARKINGS OR COMMENTS SHALL
NOT BE CONSTRUED AS RELIEVING THE CONTRACTOR FROM COMPLIANCE WITH THE
PROJECT PLANS AND SPECIFICATIONS. NOR DEPARTURES THRERFROM. THE
CONTRACTOR REMAINS RESPONSIBLE FOR DETAILS AND ACCURACY, FOR CONFIRMING
AND CORRELATING ALL QUANTITIES AND DIMENSIONS, FOR SELECTION FABRICATION
PROCESSES.
ACCESSIBILITY NOTE:
THE TELECOMMUNICATIONS EQUIPMENT SPACE SHOWN HEREON THESE PLANS IS NOT
CUSTOMARILY OCCUPiED. WORK TO BE PERFORMED IN THIS FACILITY CANNOT
REASONABLY BE PERFORMED BY PERSONS WITH A SEVERE IMPAIRMENT: MOBILITY,
SIGHT, AND/OR HEARING. THEREFORE, PER 2016 CALIFORNIA BUILDING CODE
SECTION 1103B.1 EXCEPTION 1, THIS FACILITY SHALL BE EXEMPTED FROM ALL TITLE
24 ACCESS REQUIREMENTS.
BID WALK NOTES:
1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONSTRUCTION CONDITIONS BEFORE
SUBMITTAL OF FINAL BIDS, START OF CONSTRUCTION AND/OR FABRICATION. AFTER
THOROUGHLY EXAMINING THE PLANS AND EXISTING SITE CONDITIONS NOTIFY THE
ENGINEER IN WRITING OF ANY OMISIONS/DISCREPANCIES, OR ANY ITEMS NEEDING
CLARIFICATION PRIOR TO SUBMITTING FINAL BIDS.
2. IF THE ENGINEER IS NOT NOTIFIED OF ANY OMISiONS/DISCREPANCIES OR
CLARIFICATIONS IN WRITING AS DESCRIBED IN #1 IT Will. BE CONFIRMED THAT THE
CONTRACTOR HAS CONSIDERED ALL ITEMS THAT WILL AFFECT THE COST OF THE
CONSTRUCTION OF THE SITE UNDER THE MOST STRINGENT CONDiTIONS. THE
CONTRACTOR WILL NOT BE ENTITLED TO ANY ADDITIONAL COMPENSATION AFTER
FINAL BIDS HAVE BEEN SUBMITTED AND AWARDED FROM CARRIER.
STRUCTURAL STEEL:
1. ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE LATEST
REVISED EDITION OF THE AISC MANUAL OF STEEL CONSTRUCTION, WHICH INCLUDES
THE SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, THE CODE OF STANDARD
PRACTICE AND THE AWS STRUCTURAL WELDING CODE. IDENTIFY AND MARK STEEL
PER CBC 2016.
2. STRUCTURAL STEEL SHOP DRAWINGS SHALL BE REVIEWED BY THE
ENGINEER/ARCHITECT PRIOR TO FABRICATION.
3. GROUTING OF COLUMN BASE PLATES: BASE PLATES SHALL BE DRYPACKED OR
GROUTED WITH NON-SHRINK, NON-FERROUS GROUT. MINIMUM COMPRESSIVE
STRENGTH SHALL BE 4,000 PSI AT 28 DAYS. ALL SURFACES SHALL BE PROPERLY
CLEANED OF FOREIGN MATERIAL PRIOR TO GROUTING.
4. ALL EXPOSED WELDS SHALL BE FILLED AND GROUND SMOOTH WHERE METAL
COULD COME IN CONTACT WITH THE PUBLIC.
5. NO HOLES OTHER THAN THOSE SPECIFICALLY DETAILED SHALL BE ALLOWED THRU
STRUCTURAL STEEL MEMBERS. BOLT HOLES SHALL CONFORM TO AISC
SPECIFICATION, AND SHALL BE STANDARD HOLES UNLESS OTHERWISE NOTED. NO
CUTTING OR BURNING OF STRUCTURAL STEEL WILL BE PERMITTED WITHOUT PRIOR
CONSENT OF THIS ENGINEER.
6. WELDING: CONFORM TO AWS D1 1. WELDERS SHALL BE CERTIFIED IN
ACCORDANCE WITH WABO REQUIREMENTS. USE E70 ELECTRODES OF TYPE REQUIRED
FOR MATERIALS TO BE WELDED.
7. BOLTING:
ASTM A307 BOLTS SHALL BE INSTALLED "SNUG TIGHT" PER AISC. SECTION RCSC
8(C) ASTM A325 BOLTS SHALL CONFORM TO THE RCSC SPECIFICATION SECTION 8
(D).
8. FABRICATION: CONFORM TO AISC SPECIFICATION SEC M2 "FABRICATION" AND
AISC CODE SEC 6 "FABRICATION AND DELIVERY" PERFORM WORK ON PREMISES OF
A FABRICATOR APPROVED BY THE BUILDING OFFICIAL.
9. GALVANIZING: ALL EXPOSED STEEL OUTSIDE THE BUILDING ENVELOPE SHALL BE
HOT-DIPPED GALVANIZED. APPLY FIELD TOUCH-UPS PER SPECIFICATIONS. PER ASTM
A 153.
STRUCTURAL STEEL:
MATERIALS: CONFORM TO
ANCHOR BOLTS (HEADED):
ANCHOR BOLTS (J-TYPE):
BARS & PLATES:
BOLTS:
C-, M-. AND ANGLE SHAPES:
DEFORMED WELDED WIRE FABRIC:
EPOXY & EXPANSION ANCHORS:
GROUT:
HIGH-STRENGTH BOLTS:
OTHER STRUCTURAL SHAPES:
REINFORCING BARS:
SMOOTH WELDED WIRE FABRIC:
STRUCTURAL WF SHAPES:
STEEL PIPE:
TIE WIRE:
TUBE STEEL & PIPE COLUMNS:
WELDING ELECTRODES:
W -SHAPES:
STRUCTURAL STEEL NOTES:
ASTM A307
ASHA A36
ASTM A36
ASTM A307
ASTM A36
ASTM A497
HILTI OR EQUIVALENT
EMBECO OR EQUIVALENT
ASTM A325SC OR (A325N)
ASTM A36
ASTM A615. GRADE 60, DEFORMED BARS
ASTM A185
ASTM /l.572-GR50
ASTM A53, GRADE B
16.5 GAGE OR HEAVIER, BLACK ANNEALED
ASTM A500, GRADE B
E70XX
ASTM A992, GRADE 50
1. HOLES IN STEEL SHALL BE DRILLED OR PUNCHED. ALL SLOTTED HOLES SHALL
BE PROVIDED WITH SMOOTH EDGES. BURNING OF HOLES AND TORCH CUTTING AT
THE SITE IS NOT PERMITTED.
2. ALL FRAMING CONNECTORS SUCH AS CONCRETE ANCHORS, HOLD-DOWNS, POST
BASES, FRAMING CAPS, HANGER AND OTHER MISCELLANEOUS STRUCTURAL METALS
SHALL BE AS MANUFACTURED BY SIMPSON STRONG TIE CO. OR APPROVED EQUAL.
SCALE:
N.T.S. 2
!J"! --Mobile~
PLANS PREPARED BY:----------.
INFINIGY8
ENGINEERING, LLP
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB NUMBER: 581-100
CONSULTING GROUP:---------
•NO.--DATE: DESCRIPTION: BY:
0 05/14/19 90% CD'S JG
1 05/24/19 100% CD'S CAM
2 06/19/19 100% CD'S CAM
3 08/05/19 ZAP COMMENTS CAM
SITE INFORMATION: -----------,
CARLSBAD INN
SD06298A
3001 CARLSBAD BLVD.
CARLSBAD, CA 92008
SEAL:----------------.
SHEET TITLE:
ABBREVIATIONS,
SYMBOLS, GENERAL
NOTES &
SPECIFICATIONS
SHEET NUMBER:------------,
T-2
\
\
l
\_ (E) PARKING AREA\
' ' ' ,\\\\\
\ \ \ \ \ \ \
', \ \, \ \ I \\\\\\\
,.\\\\\'
\ \ \ \ I \ \ \ '
. '
\_ (E) BUILDING\
\ .,
\
\_ (E) BUILDING\
SITE PLAN
,r--:::: EXISTING T-MOBILE
...L_ /1/ ALPHA SECTOR
\
\
\
EXISTING T-MOBILEEB PROJECT, AREA OF
PROPOSED WORK -
\_ (E) BUILDING\
\
/ (E) TREE (TYP.)
EXISTING T-MOBILE
GAMMA SECTOR
/
/
I
I
I
I
I
I: w
I g,
"' I CL
II
I I
t
I
j
1/
I I
/I
ii . I
I!
I I
I ...., ;: Fi "-
SECTOR 'C'
140°,
NOTE:
SITE PLAN IS PRELIMINARY
AND DONE WITHOUT THE
BENEFIT OF A SURVEY.
I~
I I
I
I
I
I
I
'
N
SCALE: ~
1/16"=1'-o" o 8' 1s'
(
1
~-(E) T-MOBILE EQUIPMENT CABINET
"' "' \
\
~---+-..._ ---_) .....__ -__/
-__/
(E) T-MOBILE EQUIPMENT CABINET @
W / (E) ( 1) DUL20 TO BE REMOVED A 2 INSTALL (2) 886630 -
\_ (E) ROOFTOP\
Qi)@ EXISTING ANTENNA LOCATION--~
ENLARGED SITE PLAN
/
I
-----------
0 ~1!
0 :
' \
l
I
I
I .____~ ""' '>.I . I
I O'IVtL/ " I \ ~--~ !
\ I ' / -------------
SCALE: ~
3/8"=1 '-0" 0 1' 2' 3' 2
.~··Mobile·
PLANS PREPARED BY:----------,
INFINIGY8
ENGINEERING, LLP
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB NUMBER: 581-100
CONSULTING GROUP:----------,
NO.-.-DATE: DESCRIPTION: BY:
0 05/14/19 90% CD'S JG
1 05/24/19 100% CD'S CAM
2 06/19/19 100% CD'S CAM
3 08/05/19 ZAP COMMENTS CAM
SITE INFORMATION:---------,
CARLSBAD INN
SD06298A
3001 CARLSBAD BLVD.
CARLSBAD, CA 92008
SEAL:--------------.
SHEET TITLE:------------,
SITE PLAN &
ENLARGED SITE PLAN
SHEET NUMBER:-----------,
A-1
ANTENNA
SECTOR
ANT. TECH. MODEL SIZE
A1 U1900 AIR21 B2A/B4P 56" G1900 :<{
a:::: A2 N/A N/A N/A 0 I-(_) w
U)
A3 L2100 AIR21 B2P/B4A 55"
U1900 B1 AIR21 B2A/B4P 56" G1900 co
a:::: B2 N/A N/A N/A 0 I-(_) w
U) AIR21 B2P/B4A 56" B3 L2100
C1 U1900 AIR21 B2A/B4P 56" G1900 ' (_)
a:::: C2 N/A N/A N/A 0 f--(_) w
VJ AIR21 B2P /B4A 56" C3 L2100
ANTENNA SCHEDULE
' SECTOR 'A'
320°
EXISTING ANTENNA LAYOUT
EXISTING ANTENNA SCHEDULE
ANTENNA
WEIGHT AZIMUTH
I BS
96 320'
N/A N/A
96 320'
96 60'
N/A N/A
96 60"
96 140'
N/A N/A
96 140"
ANTENNA
RAD
CENTER
45'-0"
N/A
45'-o"
45'-0"
N/A
45'-0"
45'-0"
N/A
45'-0"
TMA / RRU
(2) TWIN STYLE 1 B -AWS
N/A
N/A
(2) TWIN STYLE 1 B -AWS
N/A
N/A
(2) TWIN STYLE 1 B -AWS
N/A
N/A
SECTOR 'C'
140°,
CABLE TYPE CABLE LENGTH
(4) 7/8" COAX
( 4) FIBER JUMPER
N/A 164'
(2) FIBER JUMPER
U)
(_)
I
<D
( 4) 7 /8" LMU COAX X n
( 4) FIBER JUMPER ~ -~
N/A
-------
175'
<D -X
( 1) FIBER JUMPER n
U)
(_)
(4) 7/8" LMU COAX I
~
( 4) FIBER JUMPER N
~
N/A 110'
( 1) FIBER JUMPER
_,,--(E) T-MOBILE 56" AIR21 PANEL AtfilNNA
TO BE RELOCATED (1 PER SECTOR, TOTAL 3)
,
SECTOR 'B'
60°
~-(E) T-MOBILE 56" AIR21 PANEL ANTENNA
TO BE REMOVED ( 1 PER SECTOR, TOTAL 3)
N
SCALE: ~
3/8"=1'-o" o 1· 2' 3' 1
----------------~
PROPOSED ANTENNA SCHEDULE
SECTOR
;,:
a::::
0 f-(_) w
U)
co
a::::
0 f-(_) w
VJ
' ,o
a::::
0 f-(_) w
U)
ANTENNA
ANT. TECH. MODEL SIZE
A1 L2100 AIR32 B66/B2A 56.6" L1900 KRD901146/1
L700 COMMSCOPE A2 L600 FFHH-65A-R3 48.2"
N1900
U1900 A3 AIR21 B2A/B4P 56" G1900
L2100 AIR32 B66/B2A B1 56.6" L1900 KRD901146/1
L700 COMMSCOPE B2 L600 48.2" FFHH-65A-R3 N1900
U1900 B3 AIR21 B2A/B4P 56" G1900
L2100 AIR32 B66/B2A C1 56.6" L1900 KRD901146/1
L700 COMMSCOPE C2 L600 48.2" FFHH-65A-R3 N1900
U1900 AIR21 B2A/B4P C3 56" G1900
NOTE:
• THESE ORA WINGS ARE NOT INTENDED TO BE A
VER/FICA TION THAT THE ANTENNA ANO RADIO MOUNTS
ARE ADEQUATE TO SUPPORT THE PROPOSED LOADING.
VERIFICATION THAT THE EXISTING BUILDING AND MOUNTS
CAN SUPPORT THE PROPOSED LOADING SHALL BE
PERFORMED BY A REGISTERED PROFESSIONAL ENGINEER
PRIOR TO CONSTRUCTION.
• CONTRACTOR TO REFER TO THE STRUCTURAL ANAL YS/S
AND MOUNT ASSESSMENT AND VERIFY LOADING WITH THE
MOST RECENT RFDS PRIOR TO CONSTRUCTION.
' SECTOR 'A'
320°
7
WEIGHT
LBS
99
128
96
99
128
96
99
128
96
ANTENNA ANTENNA
AZIMUTH RAD
CENTER
320' 45'-0"
320' 45'-o"
320' 45'-0"
60" 45'-o"
60' 45'-o"
60' 45'-0"
140' 45'-0"
140' 45'-o"
140' 45'-o"
(N) T-MOBILE 4449 RADIO
(1 PER SECTOR, TOTAL 3)
~ ~
PROPOSED ANTENNA LAYOUT
TMA / RRU
N/A
(1) RADIO 4449 B71+B12
(1) TWIN STYLE 1 B -AWS
N/A
(1) RADIO 4449 B71+B12
(1) TWIN STYLE 1B -AWS
N/A
(1) RADIO 4449 B71+B12
(1) TWIN STYLE 1 B -AWS
CABLE TYPE CABLE LENGTH
N/A
(4) 15' COAX 164' JUMPER V)
LLl ...J
( 4) 7 /8" LMU COAX VJ ID (_) c3 ( 4) FIBER JUMPER I
<D a:::: X LLl
N/A n ID u...
~ -,....._ ~oo
(4) 15' COAX ~
--------175' JUMPER <D ~ -( 4) 7 /8" LMU COAX X 0::: nw
( 4) FIBER JUMPER VJ 3: (_) 0 IC..
N/A ~ (_)
NC
~ ,....._
N
(4) 15' COAX ~ -11 o' JUMPER
(4) 7 /8" LMU COAX
( 4) FIBER JUMPER
3
,
SECTOR , B,
60°
.,.---(N) T-MOBILE 56" AIR32 PANEL ANTENNA
(1 PER SECTOR, TOTAL 3)
~
~ (N) T-MOBILE 48" FFHH PANEL ANTENNA
/ (1 PER SECTOR, TOTAL 3)
~ HHJH
~-RELOCATED (E) T-MOBILE 56" AIR21
PANEL ANTENNA ( 1 PER SECTOR,
TOTAL 3)
N
SECTOR 'c'
140°,
SCALE: ~
3/8"=7'-o" o 1' 2' 3' 2
!"F · ·Mobile-
-
PLANS PREPARED BY:----------,
INFINIGY8
ENGINEERING, LLP
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB NUMBER: 581-100
CONSULTING GROUP:--------
NO. DATE: DESCRIPTION: BY:
0 05/14/19 90% CD'S JG
1 05/24/19 100% CD'S CAM
2 06/19/19 100% CD'S CAM
3 08/05/19 ZAP COMMENTS CAM
SITE INFORMATION:---------
CARLSBAD INN
SD06298A
3001 CARLSBAD BLVD.
CARLSBAD, CA 92008
SEAL:--------------
SHEET TITLE:_..;._ ________ __,
ANTENNA LAYOUTS &
ANTENNA SCHEDULE
SHEET NUMBER:----------.
A-2
< :z :z w I-:z <
---' w z ~
w ---' c:,
0 ::,
I I-
g
~
0 ;-:
;,.
I ;.... ..,.
FINISHED GRADE
< z :z w e-z <
---' w :z cl':
w ---' ffi 0 ::,
~ -z ~
0 ;-:
'b I ;.... ..,.
FINISHED GRADE
PROPOSED NORTH ELEVATION
(E) T-MOBILE 56" TO BE REMOVED (tl:~R1 PANEL ANTENNA SECTOR, TOTAL 3)
EXISTING CHIMNEY
(E) T-MOBILE 56" A TO BE RELOCATED (\R2P1ERPANEL ANTENNA SECTOR, TOTAL 3)
A .U.1 II lLJ ·-·-[7 1
T
-------------~~~-J' ~I ~i-il ilsYI ti I~ 11 ~ 1')'.e'f--Jr -\f-y \' 1 /, c. LJ: LlUJJ I .lJ' ,'. I 11/1 ·} y'=(l ~ ,'~!_U ~ ' TT I: I I I ,, .,.,___Ll I , ~-;' y I' ----
_L.l_,i.;-L .. J i. u I I I i I I I I '--,y -~ \ / -./ u
( llJ WJJ_Jir~UL: _w.u• ,JL,K --· ~--/-, 'f i i1 , U : ' ILJI ilL_j' · --/.', ';ij•-/ \v''--" ---1 ii Ye ' .;u)c •IP .cu, , , --! t=✓ •' u LE . 1 u1-u · , . . _rrtrr-_-• n ·: c " A '--+ ' '' I' T; nW, ·,~ ... ~,:-~~:-A~_/<-.11.c ji':~j 11lj1c.JµJJ_LJl_ULJI ,uJ~,1• +½J1 -~,wuu I' i i Ii I W· I --'I 1'
1
,I.I,~ I Ii I [1117'{; 'L _, , '-/' ' C' ' LU---'·/.,'-J .iL' ' I ' ILi I ' 'I I ~·~-LJ ' ' ' u ' LJ' I ' I ' i I I ~I 11 I I 1 · ' I
I ' ' 'TT · :7 -r 'i> --}-CC II ' 11_1 H T ~ ' ' ,illJ _J_,_j I li 11 ,-·«1~1 I u·~-lJ_IJJJ_lJ_UJ u 'I llJ 71 ' ' ; I' /J!JlJII• ,,:V •CY -;jjlT'l!!''T-'T;~,,1-J-u_JJ1_lill!IJJ ·1--i-l ', ,_1,,LUUlLJLlli JJl-.J,U ,D l 1, I
"' w I-:z w u
0 < "' < :z :z w I-::;;
---' w :z ~
w ---' c:,
0 ::,
,.!_
g
~
• 0 I
"' ..,.
"' w 'a= w u
0 ~
~ :z w I-:a'
---' w :z ~
w =' c:,
0 ::,
I I--3
°" -~
• 0 I
"' ..,.
All
,I ;JTn;n___ lllilill lollll ',?,g~-~1LlLr1 · -1 J .• -1
11 ;uhl'_{ 11 .;·+-TYT 1 1~J-¼~OfU~1t1
,llLJLLJJI !I! 1
7
il I ' ,~r-,::;:'~-0;'--Y. I 'II IT jj" '111 1' ,L,1'L,.'J 11L Ji "l i; I 11 u' ,: I I
11
Ii ii II i I '! I u' iLJ' I' 'i i : T!
J U U_u
, .
1
--, , , , , . ,, y ,/-~ / , , 1 1 1 1 N n Ti IL LL 1 I
I J1 u, I L'J.J : , 1 -r , .
lyf/.J-L_',7 I II ,' H: I ~)1,lll1Lili,7UJ! ,-,--( r~w~). /",~,,Cc1 ; I I, ' , ]I ,1c: I'[! I 'TT[~ I_I u 11r1
1
l_j~,
1
)qJ_LJJ~.il' I' I I!
" •' 1 ,U ,,r -,_~,J,-1 ~ 11 · L ii ' 1
• '-,\~ 1 ,"1--~~ ' ' 7t~:/~;f?::~::s-l+ci·JTJ~01;vu;.d:~·u,Utf-~fri irlu~,1_1,jluJII ,'Jlltfill I II I l~I 1,J '11 ul !_1r~iu-1,,11Tu!i 11 Jlu ,i.L_llW ! ~\-
. •_/?' 1' // . " ! ;: ' ' I I i ,, J. . I ' : t I I I __ LJ __ , -,"-' --LJ__JJ I /Tl ' ' I 11 ~--"'"' .~--/-.__., .J ! , ·, 1 1 T ·; .. ., ·i'fn · U __ lJ LI U I LI 1 , I ·1· 1 ··· ---'-cl -+,; .. ,. -r, -P-._ ' • ,, , "" -.•.~~U 1
-u 11 1
11
1
,.,----,!-,-_:,_ ,-'' "---·-·•"' ,,
-. ··-/' . ' ' ' .
If·~ ,'.b,, ·C( ,. ' • ~ 7-y ,0 ,,,-,.
I // '.\ ✓-::-1 I '
:_'=-ft:-::::-./ ( / \__// )\ j/ /--, / \) ,-~--r-, \ ,,,,/-,_/( ~-\ \_ __ ) i. \ r-=:::::: r ...... ,. \ ... _
\ (;' '--. .,/.---i ~-, <--\-...__..l "'-~/ \ ) (-----•, ;r-·• ' ,_. .r-··· ~ -.--,...J -~! /<2( >'t.~~\?t-r=-=-=-=-=-=-=--=-=-=-=-=-=-=-=-=-=1nnn;:;;:;;:;:d .,; ✓,.1
/'· ,),/ 'I. .' _:1· / J-// ', _)_ '-.,j( )\ __ /l~ )/_. ' ,-;'/ 111 =-r "" '--'/--\__ 1 \ ___ .// .,..;:-rr , 1 _) ~ \ r---, . \ ,--:.,,,-r--..__ \_ , ,.. ' 1' I /
--','...-/' ,, ;• •--~ ' ' \';:' ~-.( . .-·,s> ':-J· ~.;c._j \._~-l i UJP" /
' i •~, i( -Y \';r.:.-/--\ C '/
/,, ··,, j~l i \ Y /( / .'\ //' ',\ j~·"::.'i J \
\ __ ,;-!-"~~_/ < j ·, _,,,/' i\ J-~ ~-; '· ,...-' -..-,f------.. \ J 1-..._/ ( ) ' ) \. ..._, I \ -._._,_,.y-.._ \ '· ' , __ _.,.<, }\ )( \( '=::_, ',.____._. I / '-___,'
(N) T-MOBILE 4449 RADIO
MOUNTED BEHIND CHIMINEY
( 1 PER SECTOR, TOTAL 3)
(N) T-MOBILE 48"
i'
ii
RELOCATED (E) T -MOBILE 56" AIR21 PANEL ANTENNA ----
( 1 PER SECTOR, TO~:t 3f ANEL ANTENNA
i ''
( 1 PER SECTOR, TOTAL 3)
(N) T-MOBILE 56" ( 1 PER SECTOR, TO~:c~rANEL ANTENNA
EXISTING CHIMNEY
CJ ~ :_; _: 1 ;· LIJL: l_ i ILJL . ~~-·-·17(-· /2 ··--\ (.,J ·~--~~-, lit
.. ·; ',, . ' , . . L' .. :• '< .., L.'. , . ''_JJJJ'' , , , _ .L_J ~1 ,I , ',,-·,-·,,·-.I: I' 'J.L U• j\ . ,>L ·~Ll'
---i ' , ' ' ' .Ll_ , ,, I a• ---::-.~~-:: ' 11J ' i""
,'-----1-_:'.Tf •';"-'" •11 _l,LJ W '. ,-'/ -·y •:n --,,_ • 1 ---11 fl] -c ___ .L:._.1..1J.1 _ _u__,,1 ,:·.111 1v=:;. //~1 _.p,,,·,w· .. yu, · 1:11.u 1, l·JL·'-1.w. __ _ . _u
1
,.11
11
:~·-1
,_c.-L.I I i : ,'_) i I \ 111,LLil,lLJ I ' ;: ( --11 lJ ' ''
, --I ,_,~ . , , -// . _/( ~ . , u UlJ' w· u·U'-'-~· U_I ,u· ,1 I' . I i .• :r. . 4---L.L''L(Oi : '-:"r--"'';/'--.:"5,y'.:.., _(J_Ll, J '' ' Ill~ 11 i':' 'I lfL;I 'UJJLJI1Lu·oj_uuLJ..I u', l i~l~DLJliLJLJ ', 'lll' ~: 1',11fuu~ ,wlliJ-'1·· \':>---;,~~\...--'\ __ :, 1,:1 ~u,"T"'-' U-~-JLJL :u' 11 I[ 'I ,·,I _JI Iii :' 1:,, 11·1,L-1',•,' '' : I I • , -ry ,v --.1,-,yL II-'" '1 ·11"''1~~ · lLLJ''
•y u,~1~ u•, /'-J P(~;-11' 11.~l l O! -ur r u -" ,liTIJ~---~11 u ,IU (IIF--i ·1 ' Iii! 1!1111111 1111111111 JIii :. ~';-:, ,, ' olJ LJULll11111r1'11_jj '~-:...c.1 ,' hrfu1111/' ,WJ1 ·'1'-.1U_~_1wi i i_ i1·1rnu ~uu_ulrLiu_L_.ll\ 11 111 ..
lJU UWJ
.
1
, .c-, --~, ,j• · .... ,,,,·L'1 1·1,··11r·' ;.LJ'
1LJ1t111•w~--, ~ 11· 1
1
, --' • I I , , ' ' ,--j _,,.-/ ~./_----' I I I rT' -0 c Co0J UL) I u· ! --'11-iN ! ;j Ti 7 ui--1 cl!'-a!, ll,.1
L,:--Y u ·1,u u lL;J_uJ1_J I ,' 1' '', --l • y'"-,1, )AJ •~Y 111 I I I "1 " I ,-• I u --l nLJ1
1 ,u1 .Li1,J' 'I ! f7[JLU1l ll l I ! I' ,
1
1
1
I L
' I i : -, ~ILL-Lo-~--~-I, -=-,;!--:::_/'.~ ) __ ,.--7 ',\ / ' ' ' I ' : I I ''I' I I . ''II LJJ I u:1 I!' -II ·1~11,.tl.' ' ' I I ',-,, --~";---_, _/----.__/( ~-'u' ', ,, ,LJ ,, I 111--_J, ', •l'r--~.,.J
I '' ' ' ,1."> .... ;.s\_ .. 1 C:Ji ; r-~:: I I l j Ii ' ! I I I ~---1,,:,' 11 I II I I ! 'I i I I! 'I i 1, I i JlJ1JL1W ' , I ' "(j •'f Cf V-'7 '-"'-Ll U o-+'--¼cc -_,LillLJI I U , • '> ----0 u !I U O II I I ·I · ' , . v--·" r' •--·, ,_) Y, 1 ···. •, .I.J_11." uu u 11:, u -u . 1, 1, u.u.LU_t, 1 11 tJl·
1 ,-LJJ_L]_ .. 11111 :',w-,; c~.--1 ... ..-1r-=-·' : ., ' I , I I . . I -, _:_J L U i I i LJ , LJ ll' -~-~ : ! I I I =c.-p-., _ -"'"1 .__--1/ ; /r' , 1 1 --· ·r -· _u_~_ UJ 1 , ., : I I JlJJ U --'J_ -L ' _, ,-. '.✓---"' -·--'' "' 'Jll_ill __ /, i, ) , ,-<ccf· ·-, \.__J ' , I , -1 1....... -__ J-L I L..
1
\:;,,--T--• .. j,__,,, "~ , , " ,
•. /.-.. -\ ...,,> _-~ ~ .•----' -../i · • , , I
{:=~, )(-Y ·;f"';✓-'·I.
,,:, -,,,\ r~l / ~'--::...-1! ? , · ,,.,:. ·-A 1 \ ,--7' ,,, Jr --=c::::-· (~ -----,___,-; ___ --< J '. / (
_){ \ ,~/ ~ -~-✓~-~ \
, (~--. ·~---·----/ ~/ \... .> ( ;· < \ r-'-::::.
)01/ \~(-:.,-'cc~,.> '·-7-"-:-f~=====--'-----il ;r=:.• : --r:--) .. ✓ •\ _.;r-·"· , -, ;j-------=====~k== '--J.J-~✓ < j \ __ / ';\ / -, i \ ....-:.--,;::;----._, \ ,;_ ....__,,,.-< _/\ ) ,' -;/ \ -~-:::::---1/-, \-1 -·, ,~. ·~ ____ ,..} "'~ , , 1 ·-; < ·, r---....:._ \ ,._,,,-/-\ ,--7 _____ ..,.,. '-..--/ \-. I ·• A ;/~ \ ··::---/,,-..... -, C? -----~ '--·-"_J / \ __ ., / \ "'f \r·-/ \\C,; ' --,I, Jr='! / ', __ )' i<
, __j ,________,,j' /\ /~:ZI / ,___....1--------,, \ -.:> \..___/ ( ( \ .A
< ;, C5( ~;► !::=;(~ \..-~~
' ' __/
I I I I ' ' ' 'I '.
II
11
:
1!
I
EXISTING HOTEL
' I
EXISTING HOTEL
I
SCALE:
1 /8"= 1 · -o" ~ o 4' 5' 1
NOTE:
1 · ALL (N) ANTENN MOUNTED TO TH~s (:)m EQUIPMENT
SHALL BE PAINTED TO BMU~~~~G(E).
SCALE:
1 /8"= 1 · -o" ~
0 4' 8' 2
~··Mobile·
PLANS PREPARED BY:
INFINIGY8
ENGINEERING LLP
26~;~t:,icHo PARKWAY douTH
REST, CALIFORNIA 92630
JOB NUMBER: 581--100
CONSULTING GROUP:
NO. DATE: DESCRIPTION:
0 05/14/1 9 90% CD'S
1 05/24/19 100% CD'S
2 06/19/19 100% CD'S
3 08/05/19 ZAP COMMENTS
SITE INFORMATION:
CARLSBAD INN
BY:
JG
CAM
CAM
CAM
SD06298A
SEAL:
3001 CARLSBAD BLVD
CARLSBAD, CA 92008.
SHEET TITLE:
ELEVATIONS
SHEET NUMBER:
A-3
°" w « I-z z z w w u ,;: c:,
<C ~ -' w « z z g:_ z w I-w z -' « a:, -' 0 w :::, z I « I-0.. -w w -' -ffi
d 0
>-' :::,
• ..!. ,,,
I w' 1---...-• 0 I en ...-
FINISHED GRADE
EXISTING EAST ELEVATION
°" w I-z w « '-' z z c:, w « ~ °" <C
-' z z w w z I-<C z 0.. <C
w -' -' w ffi z 0 <C :::, (L
. I w I--' -ffi 6 0 :::,
0 I I->-' -,.. 6
I "" 1--...-w' -• 0 I en ...-
FlNISHED GRADE
,---(E) T-MOBILE PANEL ANTENNAS
r---(N) & (E) T-MOBILE PANEL ANTENNAS
,---(N) T-MOBILE 4449 RADIO
MOUNTED BEHIND CHIMINEY
( 1 PER SECTOR, TOTAL 3)
PROPOSED EAST ELEVATION
RELOCATED (E) T-MOBILE 56" AIR21 PANEL ANTENNA ----~
( 1 PER SECTOR, TOTAL 3)
ii ii !! !!!1 :i
:1 !: i! !!Ii : I
1
1ii1'1i11,1 !, I. 11 '-1 I,
I;.· ii Ii. I'. 1:. I ii l;II 1:,1 ::1 1!
,,--(E) T-MOBILE 56" AIR21 PANEL ANTENNA
TO BE REMOVED (1 PER SECTOR, TOTAL 3)
r--EXISTING CHIMNEY
~-(E) T-MOBILE 56" AIR21 PANEL ANTENNA
TO BE RELOCATED (1 PER SECTOR, TOTAL 3)
,--(N) T-MOBILE 4449 RADIO
MOUNTED BEHIND CHIMINEY
(1 PER SECTOR, TOTAL 3)
,--(N) T-MOBILE 48" FFHH PANEL ANTENNA
( 1 PER SECTOR, TOTAL 3)
,--(N) T-MOBILE 56" AIR32 PANEL ANTENNA
( 1 PER SECTOR, TOTAL 3)
,,,---EXISTING CHIMNEY
c.nr•.·• ' I [i I q 11 :,, 'fl '1
11 :• I i ,I :: I I
• rnr
1
rn :, 1
1
1 1:. 1
1 !i 1i :I :i,
"."' r!
II" ',"'!"("'
: : : ·1 ., •I
;i, '-,
I '
' '
11.,,
' ' i'• '" -!::." :,, '"',
II' ' .
' ' " ' ,;, -:··
I ' '
'
I '
•
(E) T-MOBILE PANEL ANTENNAS --
;/_._; _], __ ; _,,_,
SCALE:
I ' '
'
'
ll '
'
3/32"=1 '-0"
~ 0 4' 8' 12' 1
NOTE:
1. ALL (N) ANTENNAS AND EQUIPMENT
MOUNTED TO THE (E) BUILDING
SHALL BE PAINTED TO MATCH (E).
(N) & (E) T-MOBILE PANEL ANTENNAS --
(N) T-MOBILE 4449 RADIO --
MOUNTED BEHIND CHIMINEY
( 1 PER SECTOR, TOTAL 3)
■ ' ·11 -
I
• -'
'
'
SCALE:
3/32"=1 '-0"
'
~
0 4' 8' 12' 2
r_p · ·Mobile·
PLANS PREPARED BY:----------.
INFINIGY8
ENGINEERING, LLP
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB NUMBER: 581-100
CONSULTING GROUP:----------.
NO.-... DATE: DESCRIPTION: BY:
0 05/14/19 90% CD'S JG
1 05/24/19 100% CD'S CAM
2 06/19/19 100% CD'S CAM
3 08/05/19 ZAP COMMENTS CAM
'
'
SITE INFORMATION: ----------....
CARLSBAD INN
SD06298A
3001 CARLSBAD BLVD.
CARLSBAD, CA 92008
SEAL:--'---------------,
SHEET TITLE:--------------,
ELEVATIONS
SHEET NUMBER:-------------,
A-3.1
---------------------------------------------------------------------------
'
er
<C :z
w >-
:z :z
w w
>-u
:z <C 0 <C _, er w :z <C
<C CL
:z :z w
'=I >-
iD
:z <C
0 _,
"' I
w
>-
:z if -w w -_,
iD 0 0 ,-: "' • ... I >-
I
i--g ... • 0 I ~
EXISTING SOUTH ELEVATION
er w >-:z w
<C 0 :z :z 0 w >-~ :z <C <C :z _, :z w w :z if >-:z <C
w _, _,
Ol
w :z
0 if "' I >-w _, -iD :z -0 ::,;
ci ,!.
,-: -• 3 0 I "ll
r--... w' -
0 I
"in ...
PROPOSED SOUTH ELEVATION
'
I
; :u1 i!7 , II
IHI
FINISHED GRADE
RELOCATED (E) T-MOBILE 56° AIR21 PANEL ANTENNA
( 1 PER SECTOR, TOTAL 3)
" ... •~-' q;1r• ;:.:"C', m.J:ab
FINISHED GRADE
(E) T-MOBILE 56" Al TO BE REMOVED (l ~~~ PANEL ANTENNA SECTOR, TOTAL 3)
EXISTING CHIMNEY
(E) T-MOBILE 55• AIR21 PANEL ANT
TO BE RELOCATED (l PER ENNA
-, \_, ,,.,J.-:: < i \ ._,,,(~',\ ,;;r--·-\.__, ~;: \ ,J,:__ /( __
(N) T MOBILE 4449 RADIO
MOUNTED BEHIND CHIMINEY
(1 PER SECTOR, TOTAL 3)
'
(N) T-MOBILE 24" ( 1 PER SECTOR, TO~~~\)ANEL ANTENNA
(N) T-MOBILE 5 • ( 1 PER SECTOR, \o~:~23{ANEL ANTENNA
\. __ ,-?-~ ' I' / ,\ ,,y '-' /-~ -\__ ,,::.:-: \ ,' ,._..._____,/( !\ ;/ -...__ ---\ _d,-:..._ /{,
SECTOR, TOTAL 3)
EXISTING HOTEL
SCALE:
1/8" 1' O"
NOTE;
~
0 4' 8'
1 · ~~u~~~DA~~E~~~s(:)ND EQUIPMENT
SHALL BUILDING BE PAINTED TO MATCH (E).
SCALE:
1/8" 1' O" 0 4 , 7
8'
1
2
,-PLANS PREPARED BY:
INFINIGY8
ENGINEERING LLP
26455 RANCHO p '
LAKE FOREST, C~~F~~~1 ;2~~TH
JOB NUMBER: 581-100
-CONSULTING GROUP:
NO.--DATE: DESCRIPTION:
0 05/14/1 9 90% CD'S
1 05/24/1 9 100% CD'S
2 06/19/19 100% CD'S
3 08/05/19 ZAP COMMENTS
•
-SITE INFORMATION:
CARLSBAD INN
BY:
JG
CAM
CAM
CAM
SD06298A
-SEAL:
3001 CARLSBAD BLVD
CARLSBAD, CA 92008.
-SHEET TITLE:
ELEVATIONS
-SHEET NUMBER:
A-3.2
-
_.,--NEW ANTENNA PIPE MOUNT
MOUNTING BRACKET
PROVIDED BY
MANUFACTURER
NEW RADIO 4449 871+812
0.
3®@ ®
0 0
@
D@ ©
0 @
-@ 1= ~ '
MOUNTING BRACKET
PROVIDED BY
MANUFACTURER
RADIO 4449 MOUNT DETAIL
{E) WOOD STUD WALL -~
{E) BRICK _ _,,,
{N) WALL ATTACHMENT _ _,,,
EB
(E) STONE _ _,,,
ANTENNA MOUNTING SECTION
SYMBOL LEGEND
■ EXOTHERMIC CONNECTION
A MECHANICAL CONNECTION
0
0
NEW RADIO 4449 871+812
NEW ANTENNA PIPE MOUNT
BOTTOM VIEW
SCALE
N.T.S.
(N) 3"~ SCH40
GALV PIPE
(N) PANEL ANTENNA
SCALE:
N.T.S.
:.---(E) GROUND WIRE
AWG #6 GROUND WIRE ----------. ---,1
NEW RADIO 4449
GROUNDING DETAIL
\
(N) T-MOBILE
PANEL ANTENNA
SCALE:
N.T.S.
7
8
9
MANUFACTURER: ERICSSON
MODEL NO.: ~R 32 KRD901146-1 B66 B2 (OCTA)
DIMENSIONS: W8GHT WITHOUT l!EITT 11111 ~llll.E
pru lllll' NID IIIIIXlf
A 56.6" INSTAllATION K~: llfil!!L\!Kil Kif:
.
B 12.9" 99 LBS 1 31 LBS UL
C 8.7"
B
TOP VIEW V \
FRONT VIEW BACK VIEW
(N) AIR32 ANTENNA SPEC
6630 BASEBAND
DIMENSIONS, WxDxH:
MAX POWER CONSUMPTION:
BREAKER SIZE:
TOTAL WEIGHT:
-
(N) 6630 BASEBAND
(19"x13.78"x1 .75")
180 W
MIN 1 0 A, MAX 30 A
± 14.33 lbs
-
~-VALMONT SP250 @ TOP/BOT.
( OR APPROVED EQUAL)
i~ (N) 3"i SCH40 GALV PIPE
~-1/2"~ x 5" LAG SCREWS
(TWO TOTAL @ 10" O.C.)
SEAL W/ NEOPRENE GASKET
@ EA. PENETRATION
VALMONT SP250 WALL MOUNT
--------------
D
SIDE VIEW
SCALE:
N.T.S. 4
SCALE:
N.T.S. 5
SCALE:
N.T.S. 6
MANUFACTURER:
MODEL NO.:
DIMENSIONS:
A 48.2"
B 25.2"
C 9.3"
RF CONNECTOR, TYP
COMMSCOPE
FFHH-65A-R3
TOTAL WEIGHT:
B
TOP
B
BOTTOM
72.8 LBS
RF CONNECTOR, TYP
B
(N) FFHH ANTENNA DETAILS
MANUFACTURE: ERICSSON
MODEL NO.: RRUS 4449 B12
DIMENSIONS:
15" TOTAL WEIGHT: A
B 13.2" 70 LBS (31.7 kg)
C 9.3" RADIO
MFR'S STANDARD
MOUNTING BRACKETS
C
10
SIDE VIEW
(N) RADIO 4449 871, 812 SPECS
STANDARD STEEL
PIPE (GALV)
ANTENNA MOUNTING DETAIL
MECHANICAL
DOWNTILT
BRACKET
EXISTING MOUNTING
PIPE TO BE REUSED
<(
SCALE:
N.T.S.
0 oO
0 0 0 0
OO!
BOTTOM VIEW
B
,1iiiiiiiijiiiiiiiiiijl!i
i 'iiiiiiii1!!!i!iii!!i! I ~~! ii iii !iii!! iiiiiii!i~!
iiiiiijjjjjjijjjjjjij1 j
1iiiiii!iiii!iiiii!iiiiii
ii!iiiiiiiii!iiiiiiiiii
I I I
FRONT VIEW
PROPOSED ANTENNA
MOUNTING BRACKET
PROPOSED ANTENNA
----PROPOSED ANTENNA
MOUNTING BRACKET
SCALE:
N.T.S.
SCALE:
N.T.S.
1
0
<(
2
3
r■ --Mobile·
PLANS PREPARED BY:---------.
INFINIGY8
ENGINEERING, LLP
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB NUMBER: 581-100
CONSULTING GROUP:-----------,
0 ,N .--DATE: DESCRIPTION: BY:
0 05/14/19 90% CD'S JG
1 05/24/19 100% CD'S CAM
2 06/19/19 100% CD'S CAM
3 08/05/19 ZAP COMMENTS CAM
-SITE INFORMATION:---------.
CARLSBAD INN
SD06298A
3001 CARLSBAD BLVD.
CARLSBAD, CA 92008
-SEAL:--------------.
SHEET TITLE:------------,
ARCHITECTURAL
DETAILS
SHEET NUMBER:-----------.
A-4
AIR32 B66A 82A
'
PLUMBING DIAGRAM
ALPHA
l r
' i Radio ·
L ···· --4449
AIR21 82A B4P
AIR32
B66A 82A
I ! I ,
I .
SD06298A _ 67D92D8.jpg
RBS 6131
Site Configuration 670920B -Outdoor
BETA
Radio
4449 ·
RBS 13
(Outdoor)
I
AIR21 B2A 84P
--------~-'--------------------------·~ ----------
AIR32
866A B2A
I
l
, I
I
I I I
I I I I I l q I · i I ! I
I ';
I
<, Radio ·
'-++-+ 4449
GAMMA
82A AIRZ1 84P
SCALE:
N.T.S. 1
~ · ·Mobilem
PLANS PREPARED BY:--------
INFINIGY8
ENGINEERING, LLP
26455 RANCHO PARKWAY SOUTH
LAKE FOREST, CALIFORNIA 92630
JOB NUMBER: 581-100
CONSULTING GROUP:--------
NO. DATE: DESCRIPTION: BY:
0 05/14/19 90% CD'S JG
1 05/24/19 100% CD'S CAM
2 06/19/19 100% CD'S CAM
3 08/05/19 ZAP COMMENTS CAM
SITE INFORMATION:---------
CARLSBAD INN
SD06298A
SEAL:
3001 CARLSBAD BLVD.
CARLSBAD, CA 92008
SHEET TITLE:
PLUMBING DIAGRAM
SHEET NUMBER:----------
A-5