Loading...
HomeMy WebLinkAbout1520 GRADY PL; ; CB961451; Permit,/oOt dl ly(0 - B U I L D I N G P E R M I T Permit No CB961451 '09/24/96 13:13 ' Project No: A9602103 .Page 1-of 1 ' tYevelopmentN.o: 'Jö,bAddress: 1520 GRADYPL' Suite: Permit Type: RESIDENTALDD/ALT . .. P'arce1•No: 207-021-54-00 Valuation: 83;338 Construction Type: .VN Occupancy Group: R'eference#: Status:- ISSUED 'Pescription: 454 SF ADD-MASTER BED,LAUNDRY& .Applied: 08/12/96 NOOK,REMODELKITCH&2BATHS Apr/Issue: 09/24/96 Entered By: RMA Appl/Ownr : B.A. WORTHING - 619-729-394 09/24/96 000101.' 02' P.O. BOX 1041 ' C-PRMT 0200 .CARLSBAD CA :92018 ., . Fees Required *** es Co ected & Credits ----------------------------- -c2.--- -- _j...-- - ------------ Fee: . 1,064/00 .' Adjustments: '001 Total . e : .' .00 Total Fees: 1,4 0 Tota ' 244.00 lan j: 820.00. - Fee descripti'on.. L [1 its ' ni Et fee Data. 'Building. Permit 568.00 .,Plan Check Strong, Motion Fee., 8.0,0 :: E~ch Plumbing Fixtur- or Tr 35.00 Gas Pi6ing System 1 1 > 7.00 PLUMBING -toaAL .,62.00 Enter "1" 'foi' Electric \IsFe >INCORPOR&TED . io.00 y Enter '1' for Remodel .\ \. 4 10.00 Y .'',*,ELECTRICAL TOTAL \.. fl \) 20.00 Et'r 'Y'. for Mechanical I Lie // t/ • . 15.00 1 ri Install Furn/Ducts/Heat Pumps > 1 9.00 • • 9.00 Each Exhaust Fan : ...........6.50 . 13.00' * MECHANICAL TOTAL S . S . 37-00 .. . . - * ( S •. S'S •\ -. S 5- .. . . • . S 1, -A LL IINSP."DATE7(Y - S S CLEARANI,.E . * • S • • . - . • -.--- PLAN CHECK NO. EST.VL Lj 5 PLAN CK DEPO1T / VALID. BY_____________ DATE -- .IERM1T APPLICATION .i City of Carlsbad Building Department 2075 Las PaLmes Dr., Carlsbad, CA 92009 (619)438-1161%20 1. PERMIT 1YPE From List I (see back) give code of Permit-Type: SF RAD For Residential Protects Only: From List 2 (see back) give SFD LoUe orStructure-1ype: _______________________________________________ ' 4 - 9032 08/12/96 0001 01 02 4 Net Loss/Gain of Dwelling Units ___________________________________ . - C-PRMT - - - 244.00 2. PROJECT INFORMATION - FOR OFFICE USE ONLY Address 1520 GRADY,' PLACE, B,uiIdingrSuiteNo. Nearest Cross Street - CARLSBAD, CA - LEGAL DESCRIPTION Lot No. Subdivision Name/Number . I Unit No. - Phase No. CHECK BELOW IF SUBMITTED: 02 Energy Calcs 0 2 Structural Calcs 02 Soils Report. .0 1 Addressed Envelope ASSESSOR'S PARCEL EXISTING USE PROPOSED USE REMODEL KITCr{EN/('eve.I 2.t44 SQ. FT. 4 3 ) ,. OF STORIES # OF BEDROOMS # OF BATHROOMS S. WNIAUI PER(JN (ii dilferenrlr&irapplicant) NAME(last.namefirst)WORTHING B.A. 1pRESS P.O. BOX 1041 I I' CITY CARLSBAD STATE- -CA ZIP CODE 92018 DAYTELEPHONE (619) 729-3965, - APPUGANT WONTRACIUR D AGEN.FOR CONTRADUR DOWNER D AGENT FOR OWNER..- NAME(lastnameflrst)WORTHING, B.A. INIIRESS P.O. BOX 1041 CITY Carlsbad STATE CA ZIP CODE 92018 .DAY TELEPHONE (619) 729-3965- PROPERTY OWNER NAME (last name first) WOPPEL, CAROLINE ADDRESS .1520 GRADY PLACE - CITY CARLSBAD, STATECA ZIP CODE 92002 . DAY TELEPHONE (6 1 9) 966- 1 4-8 1 CON`rfl=R NAME (last name first) WT-1NG B.A. INC. ADDRESS P.Q. BOX' 1041-i - Mct9 AO jQA/\ '. . CITLC±SB*D STATE CA 'ZIP. CODE +8 DAY TELEPHONE .6 1 ) 72 9-3965- 6 - STATEUC.# 39876-4 LICENSE CLASS B-i .CITY BUSINESS UC.# 549200 . DESIGNER NAME (last name first)— ADDRESS - - WORTHING,B.A. P.O. BOX. 1041. CITY' cRAr) -. STATE CA ZIP CODE 9201 8 'DAY TELEPHONE 729-396 STATE uc. # 392894 WORX vTttA'I1ON Workers' Compensation Declaration: I hereby affirm that I have a certificate of consent to sell-insure issued by the Director of Industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate therof certified by the Director of the insurer thereof filed with the Building Inspecti artment (Section 3&0O Lab. Q. INSURANCE COMPANY STATE FUND POLICY NO.-'---7--EXPIRATION DATE Certificate of Exemption: -I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE . ,8. OWNER-BUILDER DECLARATION - . Owner-builder Declaration: I hereby affirm that I am exempt from the Contractors License Law for the following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or - offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property .vho builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.).- . I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects - with contractor(s) licensed pursuant to the Contractor's License Law). - I am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure,' prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law • (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) - or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001). ., SIGNATURE DATE . . COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk nianagement and prevention program under Sections 25505; 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES 0 NO - Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? ..OYES .: .0-NO,., Is the facility to be constructed within .1,000 feet of the outer boundary of a school site? 4 0 YES '0 NO IF ANY OFThE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTIUCF. 9. WNSThUCTION LENDING AGENCY. - .. . -- - - I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(1) Civil Code). LENDER'S NAME LENDER'S ADDRESS . .4 - 10. APPUCfINf CLR.ICATION I certify that I have read the application and state that the above information is correct. I agree to comply, with all City ordinances and State laws - . relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection - - - . purposes. I ALSO AGREE 10 SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS' AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CX)NSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA. An OSHA permit' is required for excavations over 5'0" deep and d ti - 0; constriction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the pr vis' of s e s expire by limitation and become null and void if the - - building or work authorized by such permit is not commenced wititc 5 ays o e d of such permit or if the building or work authorized by such permit is suspended or any time after the wo kc ced r nod of 180 days (Section 303(d) Uniform Buildin,Cod1) - 'i"'kF' - .1 - •-. •.. - a CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB961451 FOR 08/22/97 INSPECTOR AREA PY DESCRIPTION: 454 SF ADD-MASTER BED,LAUNDRY& PLANCK# CE961451 • NOOK,REMODEL KITCH&2BATHS 0CC GRP TYPE: RAD • CONSTR. TYPE VN JOB ADDRESS: 1520 GRADY PL STE: LOT: 'APPLICANT: HAYWARD CONSTRUCTION PHONE: 619-436-3053 CONTRACTOR: PHONE: OWNER: PHONE: REMARKS: C/JOHN/436-3 053 INSPECTOR (-a9-- SPECIAL INSTRUCT: ' TOTAL TIME: -CID LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural' ,29 -.PL Final Plumbing 39 .EL Final ElectricalME . Final Mechanical INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 062497 FinalCombo CO PY SEE CORR LIST 042397 Service Change/Upgrade AP PY -0 31697 Frame/Steel/Bolting/Welding AP PY OFFICE/GARAGE 012397 Interior Lath/Drywall AP PY 012397 Gas/Test/Repairs AP PY 011697 Rough Combo AP PY 011697, Frame/Steel/Bolting/Welding AP PY. 122796 Shear Panels/HD's - AP PY STRAPS OK 122396 - Shear Panels/HD's AP PY 120996 Rbof/Reroof AP PY -..• 120996 Rough/Topout • PA PY UNDER FLOOR' 12069.6 Roof/Reroof CA PY - -. 110596 Grout AP PY Ftg/Foundation/Piers. 4 103096 AP PY ] a -3 4 - - ' I •. _-h,;_••w '4 t •• • ••- - * • 4 -' -• .•, - •1_ - ••.- - - ?• -,, __i_ - •:- ' '•• -• a 1 . d EsGil Corporation Professional P/Tan Review Engineers DATE:,-9/17/96 U FIRE . JURISDICTION: -Carlsbad U PLAN REVIEWER U FILE PLANCHECKNO 96-1451 SET!! PROJECT ADDRESS 1520 Grady Place c PROJECT NAME Woerpel Residential Add'n & Remodel The plans transmitted herewith have been corrected where necessary and substantially comply - with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information: The plans are being held at Esgil . Corporation until corrected plans are submitted for recheck. " ' - The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to I Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff dud advise the applicant that the plan check has been completed - + Person contacted Date contacted (by ) Telephone # .1 REMARKS: Revise floor beam F13-1 shown on sheet 4 to a 3.1/2.X 11 7/8 in accordance with the engineers design 4. - By: CHUCK MENDENHALL - Enclosures: Esgil Corporation 0 GA 0 CM 0 EJ 0 Pc 9/10/96 trnsmtl dot 9320 Chesapeake Drive Suite 208 • San Diego California 92123 • (619) 560-1468 • Fax (619) 560-1576 'a• . , - . -. . 4- , .-. \ & - ', EsGil Corporation Trofessionat Plan Review Engineers DATE 8/20/96 DJURI ANT 0 FIRE JURISDICTION: Carlsbad REVIEWER -' El FILE HPLAN.CHECK NO.: 96-1451 SET:! PROJECT ADDRESS: 1520 Grady Place PROJECT NAME Worpel Residential Add'n & Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. Eli1 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck " The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of.the check list has been sent to: - - ' ,B .A. Worthing Inc POBox1O41, Carlsbad, CA92018 . Esgil Corporation staff did not advise the applicant (except by mail) that the plan check has. been completed. -- 1k Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Date contacted (by ) Telephone # REMARKS: -- • By: 'CHUCK MENDENHALL Enclosures: energy reqmt's - Esgil Corporation 8/31/96 9320 Chesapàke Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax (619) 560-1576 0 : • - - i., _: .. :-... • •- 4 Carlsbad 96-1451 8/20/96 PLAN REVIEW CORRECTION LIST * SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 96-1451 JURISDICTION: Carlsbad 1 PROJECT ADDRESS: 1520 Grady Place FLOOR AREA: 454 New 1506 Remodel 1 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: defined. DATE INITIAL PLAN REVIEW COMPLETED: 8/20/96 STORIES: one HEIGHT: 13" approx DATE PLANS RECEIVED BY ESGIL CORPORATION: Error! Bookmark not PLAN REVIEWER: CHUCK MENDENHALL FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, '. Uniform Plumbing Code, Uniform, Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is .based on regulations enforced by the Building Department. You may have other corrections ' ,based, on laws and ordinance by the Planning Department, Engineering Department, Fire s Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with Title 24 and the follOwing model codes: 1994 UBC (effective 12/28/95), 1994 UPC (effective 12/28/95), 1994 UMC (effective 2/23/96) and 1993 NEC (effective 12/28/95). .-•, -The above regulations apply to residential construction, regardless of the code editions adopted. by ordinance. -. ..• • ' The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each ; correction item has been addressed, i.e., plan sheet number, specification section. etc. Be sure to enclose the marked up list when you submit the revised plans. A • c c.. I.p . Carlsbad 96-1451 .8/20/96 PLANS 1. Please make all corrections on the original tracings and submit two new sets of . prints, to: • Esgil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, (619) 560-1468 2. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and the 1994 UBC, UMC and UPC and the 1993 NEC FIRE PROTECTION. . 3. Show locations of permanently wired smoke detectors with battery backup: Centrally located in corridor or area giving access to sleeping rooms GENERAL RESIDENTIAL REQUIREMENTS 4 Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface This applies to the 7040 window adjacent to the master bed rm french door. 5 Show attic ventilation Minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents) Show area required and area provided Section 1505.3. • k b £ - -. GARAGE AND CARPORTS 6. Garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling. Table 3-B, Section 302.4. This applies to the garage wall - J adjacent to the new master bed rm. . J - FOUNDATION REQUIREMENTS . . .• 7 If hold downs are required, note on plan that hold down anchors must be tied in place prior to foundation inspection Section 108.5.2. 8 Show minimum underfloor access of 18" x 24" Section 2317.3. 9 Show minimum underfloor ventilation equal to 1 sq ft for each 150 sq ft of underfloor area Openings shall be as close to corners as practical and shall provide cross ventilation onat least two approximately opposite sides Section 2317.7. - - Carlsbad 96-1451 8/20/96 FRAMING Show double top plate with minimum 48" lap splice. Section 2326.11.2. Show nailing will be in compliance with Table 23-I-Q. Provide calculations for main vertical framing' members and footings. Section 106.3.3. this applies to the 24' span ridge beam over the master bed rm. 3. The 2X6 FJ @ 16" OC beneath the new master bed rm are over spanned. The max span under the provisions of the '94. UBC is 8'6" approx. The plans show the joists : spanning approx 10'. ENERGY CONSERVATION 14. Provide design calc's to show compliance with the energy standards for additions: See the attached sheet showing the min requirements. Show in the calc's the window area % and the thermal mass area Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen(s) and - - ' bathrooms. 16 Note on the floor plans that all new window and glass doors must be dual glazed To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate: Yes U - No U The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake tv -' Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact chuck Mendenhall at Esgil Corporation Thank you , -' • 4 •5 - •- - • £ .2 . V. 4 COMPONENT ENERGY REQUIREMENTS FOR RESIDENTIAL ROOM ADDITIONS - CLIMATE ZONE 7 Floor Area of Room Addition <100 ft2 100-499 ft2 500-999 ft2 >1000 ft2 INSULATION Ceiling . R-19 R-30 R-30 R-30 -Wall R-13 R-13 R-13 R-13 Floor R-13 R-19 R-19 R-19 GLAZING (FENESTRATION) U-Value' 0.75 0.75 0.75 0.75 of added fibor area <50 sq. ft. 20% + Removed 20% + Removed2 201s ,SHADING . n/a .66 3 .66 3 - .66 3 - - . . THERMAL MASS n/a - Req.' Req.' Req.' - SPACE -HEATING Note 45 (no electric allowed) * If Gas, efficiency= 78%AFUE5 78%AFUE5 7896AFUE5 If 'Heat Pump: -'.Split System, efficiency= 6.8HSPF5 6.8HSPF5 6.8HSPF5 Sinle Package System, eff.= 6.6HSPF5 6.6HSPF5 6.6HSPF5 .-T SPACE COOLING Note' If Split System, eff.= 10.OSEER5 10.0SEER5 10.OSEER5 . If Single Package, eff.= 9.7SEER5 9.7SEER5 9.7SEER5 _*f . - WATER HEATING Note 6 Note' Note Note ;-l:-- Please note that some metal-frame windows may not satisfy the U-value requirement of.. *' I 0.75. For additions and alterations only, dual glazed "greenhouse" windows and skylights may be assumed to meet this requirement. t.:2 20 of added floor area plus the area of any glazing removed because of the addition. A coefficient of 0.66 will be assumed to be provided when dual glazing is used ••, If the addition will be on top of existing construction, and: (a)If the addition has conditioned area below all portions, then no thermal mass is .-required.- (b) If the addition will be over non-conditioned area (partially or wholly) in a building - mostly of raised-floor construction (after the addition), then thermal mass is required in the.addition (equal to 5% of the area of the addition that is over non-conditioned .space). This may be .provided by showing a 2" concrete slab at hearths, countertops, etc. ' *1 (c)If the addition will be over non-conditioned area in a building mostly of slab-on- grade construction (after the addition), then no thermal mass is required. -• If the addition will be at the ground floor, and: - (a)If the addition will be in a building mostly of raised-floor-construction (after the addition), then thermal mass is required in the addition (equal to 5% of the added conditioned footprint area) . This may be provided by showing a 2" concrete slab at hearths, couñtertops, etc. " (b)If •the addition will be in a building mostly of slab-on-grade construction (after - .-. • the addition) , then thermal mass is required in the addition (equal to 20% of the added ; ., -- conditioned slab-on-grade floor area). This may be provided by covering a portion of - the slab-on-grade with tile, wood, etc. *.; •-,' - ç 5. If the existing system will be utilized (if no additional systems are needed to provide. UBC heating requirements), there are no special requirents, other than mandatory insulation for any extended ducts, etc. - 6.- If thetotal number of water heaters increases in the residence, then calculations mist be submitted to show that the entire existing-plus-addition system meets the water heating energy budget. . * . ER-RA7 - ; Carlsbad 96-1451 - 8/20/96 VALUATION AND PLAN CHECK FEE 1 JURISDICTION: Carlsbad PLAN CHECK NO.: 96-1451 PREPARED BY: CHUCK MENDENHALL DATE: 8/20/96 BUILDING ADDRESS: 1520 Grady Place .:BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VN BUILDING PORTION BUILDING AREA (ft. 2) VALUATION MULTIPLIER VALUE ($) Add'n 454 94 42676 Remodel 1506 27 40662 -Air Conditioning Fire Sprinklers - TOTAL VALUE 83,338 • U 1991 UBC Building Permit Fee Li Bldg. Permit Fee by ordinance: $ 567.50 1991 UBC Plan Check Fee Li Plan Check Fee by ordinance: $ 368.88 ,. Type of Review: • Complete Review Li Structural Only j Hourly • Li Repetitive Fee Applicable fl Other: Esgil Plan Review Fee: $ 29510 - Comments --------------------------------------------------------------------------------------------------------------------- Fire Services Review: Li Complete Review Li Suppression System •: : Li Fire Alarm Li • Other: • Esgil Fire Services Review Fee $ Comments Shet1of 1 macvalue.doc 5196 :. . S - City of Carlsbad i1. IIitI4dIpI. • 1.J11m .ti'kI .•. BUILDING PLANCHECK CHECKLIST DATE: 2 PLANCHECK NO. BUILDING ADDRESS: j5d PROJECT DESCRIPTION: p ASSESSOR's PARCEL NUMBERO1-7/—. 4- EST VALUE__________ ENGINEERING DEPARTMENT DENIAL APPROVAL Please see the attached report of deficiencies marked 4 - The item you have submitted for review has been with E. Make necessary corrections to plans or approved The approval is based on plans information specifications for compliance with applicable codes and and/or specifications provided in your submittal; standards. Submit corrected plans and/or specifications ' 'therefore any changes to these items after this date, to this office for review. including field modifications, must be reviewed by this .k office to insure continued conformance with applicable -. codes. Please review carefully all comments attached, - as failure to comply with instructions in this report can By: Date F ; resultin suspension of permit to build. El -. i By: Date:_________ L...J A Right-of-Way permit s required prior to )- construction of the following improvements: By: Date t FOR OFFICIAL USE ONLY x ox SSW` EAM ........ 441)) ATTACHMENTS . .. ENGINEERING DEPT. CONTACT PERSON DDedication Application Dedication Checklist 4 0 Improvement Application 4.' Improvement Checklist Future Improvement Agreement City of Carlsbad El Grading Permit Application ADDRESS 2075 Las Palmas Dr Carlsbad CA 92009 E Grading Submittal Checklist PHONE (619) 438-1161, Ext. 4,5 Right of Way Permit Application LJ Right of Way Permit Submittal Checklist • and Information Sheet Sewer Fee Information Sheet A-4 '-4 -. P:\D0CS\CHKLST\BP0001.FRM - REV 04/30/96 * 2075,Las Palmas Dr. Carlsbad, CA 92009-1576 (619) 438-1161 • FAX (619) 438-0894 ciT BUILDING PLANCHECK CHECKLIST SITE PLAN 3rd E. 0 0 1. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow D. Property Lines Easements Existing & Proposed Structures E. Easements Existing Street Improvements F. Right-of-Way Width & Adjacent Streets ~/C] 0 Show on site plan: ;•' A. Drainage Patterns C. Existing Topography B Existing & Proposed Slopes 'd"El' 0 Include note "Surface water to be directed away from the building foundation at a 2% gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)" [Per 1985 UBC 2907(d)5] On graded sites, the top of any exterior foundation shall extend above the elevation .' of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus two percent" (per 1990 UBC 2907(d)5) E2( 0 0 4 Include on title sheet - - • A Site address Assessor's Parcel Number Legal Description For commercial/industrial buildings and tenant improvement projects, include Total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, - etc) previously approved EXISTING PERMIT NUMBER DESCRIPTION • • - BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE 1stV -2ndV 3rdV O 0 0 5. Project does not comply with the following Engineering Conditions of approval for - - Project No. Conditions were complied with by: Date:___________________ DEDICATION REQUIREMENTS • . 000 :. - - +•4. 6. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ -pursuant to Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8-1/2" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Provide the completed application form and the requirements on the checklist at the time of luau III : Dedication completed by Date:___________ 'IMPROVEMENT REQUIREMENTS 0 7a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction * exceeds $ -pursuant to Code Section 18.40.040. T , Public improvements required as follows Please have a registered Civil Engineer prepare appropriate improvement plans and submit them together with the requirements on the attached checklist for a separate plancheck process through the Engineering Department Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. • 4'- -, -• Attached please find an application form and submittal checklist for the public A mprovements requirements Provide the completed application form and the ç - . requirements on the checklist at the time of resubmittal. Improvement Plans signed bQZ222~, 46 4'7~ P\DOCS\CKLSBp0OO1FRM Page 2 of 4YCW657 / 2 REV 04/30/96 flc/S ,L4 ; BUILDING PLANCHECK CHECKLIST 1st' 2nd' 3rd,/ El El El 7b. Construction of the public improvements may be deferred pursuant to code Section 18.40. Please submit a recent property title report or current grant deed on the 4 property and processing fee of $ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit Future public improvements required as follows Improvement Plans signed by: Date El El 0 '7c. Enclosed please find your Future Improvement Agreement. Please return signed and • notarized Agreement to the Engineering Department. Future Improvement Agreement completed by .4 4. Date:_____________ Ui .. 0 0 •: 7d. No Public Improvements required. SPECIAL NOTE: Damaged or defective • improvements found adiacent to building site must be repaired to the satisfaction of 4 the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11 06030 of the Municipal Code Ba. Inadequate information available on Site Plan to make a determination on grading : requirements Include accurate grading quantities (cut, fill import, export) El 0 8b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be Submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit Grading Inspector sign off by Date 0 8c No Grading Permit required - * I.- I P\D0cS\CHQST\B001 F Page 3 of 4 S. • - .... BUILDING PLANCHECK CHECKLIST MISCELLANEOUS PERMITS lsjf2ndv' 3rd' IIZI ,.D 0 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to street improvements, trees, driveways, tieing into public storm drain, sewer and water utilities. Right-of-Way permit required for A separate Right-of-Way permit issued by the Engineering Department is required for the following: • • •• • - - A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. . El 11. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Permit - Industrial waste permit accepted by Date * - ..•'• - • I 4- - - • •-, S -•-,•.• -. S. S .. - * •-- :H S * P:\DOcS\CIiKLST\BP0001.FRM Page 4 of 4 • v 04/30/96 rç PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB Q /i'S7 Address /520 PL Planner Van Lynch Phone (619) 438-1161 ext. 4325 (Name). APN 2 7 (2Q i - SY Type bf Project and Use: Zone /1'- /._75tZ Facilities Management Zone:_ Z CF[[)/ #_- ,.' creI (If property in, complete SPECIAL TAX CALCULATION WORKSHEET provided by Building Department) Leqend 0 N co Item Complete 'O•' -Item Incomplete- Needs your action - CD- CD -. - -r 0. - 0 Environmental Review Required YES NO fr\ TYPE '- LDATEOFCOMPLETION Compliance with conditions of approval? If not, state conditions which require action Conditions of Approval E1 Discretionary Action Required: YES NO TYPE APPROVAL/RESO NO DATE PROJECT NO OTHER RELATED CASES: Compliance with conditions or approval" If not, state conditions which require action Conditions of Approval, _) • '.-' ' California Coastal Commission Permit Required YES NO DATE OF APPROVAL San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA 92108 -) (619) 521-8036 ,. Compliance with conditions of approval" If not, state conditions which require action Conditions of Approval - LV'IJ F-1 Inclusionary Housing Fee required YES,., NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993) Site Plan 0 Provide a fully dimensioned site plan drawn to scale. Show: North arrow, poperty lines, easements, existing and proposed' structures, streets, existing street improvements, right-of-way width,. dimensioned setbaáks and existing topographical lines 4 0 0 Provide legal description of property, and assessor's parce1 number. Zoning / . Setbacks iLY 0 0 1 r Front: Required 2e.' Shown Z9 '- Int. Side: Required (M" (p Shown Street Side: Required Shown Rear: Required •?-o' V Shown (O01 Ucc' &W F V Lot Coverage Required _c{C) Tt Shown . 0 Height: Required Shown /ct47 0 Parking: Spaces Required._- L_- Shown V 2... V Guest Spaces Required - Shown 0 0 0 Additional Comments - V.-. _. STATE 'OF CALIFORNIA—THE RESOURCES AGENCY - PETE WILSON; Governor CALIFORNIA COASTAL COMMISSION S,,N DIEGO COAST AREA 31 1 CAMINO DEL RIO NORTH, SUITE 200 Z.e.1sI DIEGO, CA 92108-1725 521-8036 EXEMPTION LETTER 19-6 DATE NAME: FF_ wr__N~111111 A'x 'L/[ LOCATION: ~;o (¼ -. (2ik ftc,z.4'a-.. )I L&dA AZ4')_. az 7 ,9-t1z :; OIh//((S . o - -. • I .-_ 'I *.-_ --I , • -. -. This-is tocertifythat'this location and/or proposed project has been -' reviewed by the staff of theCoasta1 Commission. A coastal development permit Js not necessary for the reasons checked below. - - The site is not located within the coastal zone as established by the -California Coastal Act of 1976, as amended. - - ' The-'proposed development is included in Categorical Exclusion adopted by the California Coastal Commission. •-- -: '• "-- ____ 'The proposed development is judged to be repair.or maintenance -. ivity not resulting in an addition to or enlargement or expansion' .. ' of the object of such activities (Section 30610(d) of Coastal Act). - The proposed development is an improvement to an existing single family residence (Section 30610(a) of the Coastal Act) and not , located in the area between the sea and the first public road or • •- within 300 feetof the inland extent of any beach (whichev.e.r is - greater) (Section 13250(b)(4) of 14 Cal. Admin. Code. ' -' - The proposed development is an improvement -to an ,existing single ': -- family residence and Is •located in thearea between the sea and the first public road or within 300 feet of the inland extent of any beach (whichever is greater) but is not a) an increase of 101. or moce of .internalflôor area, b) an increase in height over 101., or c) a significant non—attached structure (Sectioris3061'0(a) of Coastal Act - . and Section 13250(b)(4) of Administrative Regulations). ..- - - .. (OVER) The proposed development is an interior, modification to an existing use ffij ... t'11-0wiMon change in the density or intensity of use (Section 30106 of 1/:'J'1Coas'ta1 At) ifi I ' U i i The; .proposed development involves the nstallation, testing apd,placement ' in service of a necessary utility connection between an)xi tingI service LrI facility and development approved in accordance with coastal development - permitrequirements, pursuant toCoastal,Act Sectiod30610(f)Q-\ The proposed development is an improvement toastructure other'\than a single family residence or public works facility and is not subject to a permit requirement (Section13253cofAdministrativeRegulat1ons) Theproposeddeve1opmentis therebui1dingof,a structure, other than .a . _uhlicworksJadj,.Lty,JIestroyed liy natural disaster. Th replacement rconforms to all 6f Act Setion 30610() -. Other:,.`-, (4 9j d Please be advised that only the project described above is exempt from the permit requirements of the Coastal Act. Any change in the project may cause it to lose its exempt status. This certification is based on information 'provided by the recipient of this letter. If., at a later date, this i n-formati on 's'found'th be'4ncrtect'ci 4&oml ete,. thi s letter Wi 11 become'' invalid, and any development occurring at that time must cease until a coastal development permit is obtained. . . Truly yours, . . . . By: Ti tie:-, --------------_____ .-... k 17 : (e~r4 .., 4p?f *ed : I/4'4 M 2'10 A,4a V t4'cfa 'citf 44 gt hfti • ': cum Flo IA %\ /i:# x . ..;.. 2. . • • •• . • :. • . 8'ewu•.. --'-• chd 1ciKYifluIi47M _____ fl'; -r 627 )w lei fr • ____\ . . - .. •.,--.•-. •,•e ••#tIl - ••.•1• f•• I • - .•.1 . •.,1•• t IIflPTI-1TII( THI Tfl :1-F1q-77q-fl7 flrt 1,96 5:49 No.002 P.05 : 1 \ \ '- c _ - i \ N" L - - o 62( / 4,. I 'I - I - T //_ I _ = (/2-) 4- (S15- C ....,./ ;• -- -- - - - - - -