HomeMy WebLinkAboutPRE 2018-0008; ABEDI MOGHADDAM FAMILY RESIDENCE; Admin Decision LetterS-B-li" ^City of
Carlsbad
May 7, 2018
Varoozh Torossian, P E
1823 Bara Road
Glendale, CA 91208
SUBJECT: PRE 2018-0008 (DEV2018-0051) - ABEDI MOGHADDAM FAMILY RESIDENCE
APN: 215-460-06-00
Thank you for submitting a preliminary review for construction of a single-family residence project
proposed on Lot 727 of Map No 7367 (APN 215-460-06-00) The project site, an approximately 30,927
square foot (0 71 acre) lot, is currently undeveloped
In response to your application, the Planning Division has prepared this comment letter Please note that
the purpose of a preliminary review is to provide you with direction and comments on the overall concept
of your project This preiiminarv review does not represent an in-depth analysis of your proiect. It is
intended to give vou feedback on critical issues based upon the information provided In your submittal.
This review Is based upon the plans, policies, and standards in effect as of the date of this review. Please
be aware that at the time of a forma! application submittal, new plans. poUcies. and standards may be
in effect and additional issues of concern may be raised through a more specific and detailed review.
Planning'
General
1 General Plan and zoning designations for the property are as follows
a General Plan R-1 5, 0-1 5 dwelling units/acre (du/ac) Growth Management
Control Point of 1 du/ac
b Zoning R-1-15000
c La Costa Master Plan (MP 149(R))
2 The project requires the following permits
a Building and grading permits for the construction of a single-family residence
3 The project site is located within the La Costa Master Plan, MP 149(R) The Master Plan defers to
the Carlsbad Municipal Code, specifically the Zoning Ordinance (Title 21), for the development of
the subject site
Community & Economic Development
Planning Division 1 1635 Faraday Avenue Carlsbad, CA 92008-73141760-602-46001760-602-8560 f j www carlsbadca gov
PRE 2018-0008 (DEV2018-0051) - ABEDI MOGHADDAM FAMILY RESIDENCE
May?, 2018
Page 2 . „ ,
it t; I; I.
4 Pursuant to Carlsbad Municipal Code (CMC) Section 2110 050 (R-1 zone), the addition is limited
to a height of 30 feet and two stories if a minimum roof pitch of 3 12 is provided and 24 feet and
two stories if less than a 3 12 roof pitch is provided Because the property does not have a Zoning
designation of R-1-15000 or greater, 35 feet is not a permitted height Based on the preliminary
sketches provided, it appears that the proposed addition may not comply with the above-
referenced standards, particularly in the area of the central portion of the home
5 The plans submitted showing a basement do not appear to meet the City's standard Pursuant to
CMC Section 21 04 045 a basement means that portion of a building between floor and ceiling
which IS completely or partially below the existing grade or finished grade, whichever is lower,
but so located that the vertical distance from exterior grade to the adjacent intenor floor below
IS greater than the vertical distance from exterior grade to the adjacent interior ceiling above
This definition mustapply to a minimum of seventy-five percent ofthe perimeter of the basement
for that portion of a building to qualify as a basement
At submittal, please correct plans to clarify that area is a basement per the above definition, or
redesign the residence so it contains only two stories
6 Within the building plans, provide cross sections ofthe house and downhill slope to demonstrate
the height and multiple habitable floors to qualify as a two-story single-family residence
7 Although construction of a single-family residence on a lot is exempt from requiring a Hillside
Development Permit, this project will need to meet all ofthe standards and guidelines of CMC
Section 21 95 140 While insufficient information has been provided to determine if the following
development standards apply, please be aware ofthe following sections in addition to the rest of
CMC Section 21 95 140
a Development of Natural slopes over 40 percent gradient
(i) Natural slopes which have all of the following characteristics shall be
undevelopable
(A) A gradient of greater than forty percent, and
(B) An elevation differential of greater than fifteen feet, and
(C) A minimum area often thousand square feet, and
(D) The slope comprises a prominent land form feature
b Manufactured slopes which have a gradient of greater than 40 percent and an
elevation differential of greater than 15 feet shall be subject to the following
development standards in the Hillside Development Ordinance
(i) The following types of development on or into an uphill penmeter
manufactured slope shall be limited to a maximum of six (6) vertical feet
as measured from the existing grade at the toe ofthe slope
(A) Mam building(s),
(B) Accessory building(s), and
(C) Retaining walls
(ii) Decks may be constructed upon an uphill perimeter manufactured slope
up to the required setbacks ofthe underlying zone
PRE 2018-0008 (DEV2018-0051) - ABEDI MOGHADDAM FAMILY RESIDENCE
May 1, 2018
Page 3
c Volume of grading of hillside lands should be kept to a minimum Indicate on the
plans grading quantities (i e cut, fill, remediation) and the grading volume per
Section 21 92 140
d Building setbacks and multi-level planes which parallel the downhill slope shall be
setback so that the building does not intrude into a 0 7 foot horizontal to one foot
vertical imaginary diagonal plane that is measured from the edge of slope to the
building
8 Please submit a grading plan which includes topographical contours to assist staff with the review
of the grading and building plans Per CMC Section 21.95 130, the grading plan will also need to
include a slope analysis and slope profiles on a constraints map to determine how the Hillside
Development Standards apply
9 At submittal of a grading permit this project will need to include a Biological Technical Report
(BTR) prepared by a registered,biologist in accordance with the specific requirements of CMC
Chapter 21 210, the Habitat Management Plan for Natural Communities in the City of Carlsbad
(a k a the Habitat Management Plan (HMP)) The BTR is a critical document that will need to
describe biological resources on the site, potential project impacts, and any recommended
mitigation Please be advised if the BTR identifies fauna or flora onsite that is protected by the
HMP, then the project would require a Habitat Management Plan Permit approved by the
Planning Division For guidelines on the required contents of the BTR, please also reference the
"Guidelines for Biological Studies," which can be obtained at the Planning Division's front counter
or referenced online at
http //www carlsbadca gov/civicax/filebank/blobdload aspx?BloblD=24331
10 The wet bar shown on plan sheet A4 shall be revised so it is consistent with the city's development
standards for wet bars Pursuant to CMC Section 21 04 378 1 a wet bar does iiot contain
1 Gas lines or electrical wiring exceeding one hundred and ten volts that could power cooking
appliances including, but not limited to stoves or stovetops, built-in grills, ovens (gas or
electric), microwave ovens or similar appliances
2 A refrigerator exceeding six cubic feet in capacity or rough-in space for a refrigerator
exceeding six cubic feet in capacity, (the typical dimensions of which are
a Depth of twenty-five inches,
b Height of thirty-five inches, and
c Width of twenty-five inches)
3 A sink or rough-in space for a sink with a waste line dram exceeding one and a half inches in
diameter, a depth of eighteen inches or an overall size of two square feet
4 Cabinetry or counter space exceeding eight lineal feet
11 Pursuant to CMC Section 21 04 120 a "dwelling unit" means a single unit providing a complete,
independent living facility for one or more persons including permanent provisions for living,
sleeping, eating, cooking and sanitation, and having onlv one kitchen Plan sheet A4 shows two
kitchens on the mam floor, please correct the plan showing only one kitchen for the dwelling unit
PRE 2018-0008 (DEV2018-0051) - ABEDI MOGHADDAM FAMILY RESIDENCE
May 7, 2018
Page 4
12 Landscape construction drawings are required if the project includes 500 square feet or greater
of new landscaping The landscape requirements are detailed in the Cit/s Landscape Manual
available online at
http //www carlsbadca gov/civicax/filebank/blobdioad aspx?BloblD=24086
All necessary application forms, submittal requirements, and fee information are available at the Planning
counter located in the Faraday Building at 1635 Faraday Avenue or online at
http //www carlsbadca gov/services/depts/planning/default asp You may also access the General Plan
Land Use Element and the Zoning Ordinance online at the website address shown, select Department
Listing, select Planning Home Page Please review all information carefully before submitting
Land Development Engineering;
1 Complete a Storm Water Standards Questionnaire Form E-34 to determine storm water quality
requirements for this project The questionnaire is available in the City website at
http //www carlsbadca gov/services/depts/landev/engineering asp
Preliminary analysis suggests that the project is a Standard Project and subject to installing site
design and source control BMPs per Chapter 4 of the Carlsbad BMP Design Manual and per the
Standard Project Requirement Checklist (E36) that will also need to be completed The link to the
form IS at
http //www carlsbadca gov/civicax/filebank/biobdioad aspx?BloblD=30141
List and plot any applicable BMPs on the site plan and/or preliminary grading plan
2 Submit a preliminary drainage report to determine the pre-development and post-development
drainage flows Provide necessary mitigation for the increase in post development flows or show
that the downstream storm dram facilities can handle the additional flow
3 Provide a preliminary Geotechnical study that identifies feasibility and recommendations for the
proposed development.
4 A recent Preliminary Title Report (PTR) will be required with formal project application submittal
5 All easements and encumbrances identified in the PTR must be indicated on the site plan
6 Show existing and proposed contour lines, extend at least 50 feet beyond the property lines
7 On the site plan, indicate the total proposed impervious area and total proposed pervious area
8 Provide typical Argonauta Street cross-section showing the existing improvements along the
project frontage Include approximate location of the underground utilities in the street cross-
section Show, label and dimension the existing right-of-way
PRE 2018-0008 (DEV2018-0051) - ABEDI MOGHADDAM FAMILY RESIDENCE
May 7, 2018
Page 5
9 Provide cross-sections to illustrate differences in grade ^
10 Provide the earthwork quantities (cut, fill, remedial, import or export) on the site plan
11 Design the dnveway approach to SDRSD DWG No G-14A Locate the edge of driveway 3 feet
from a prolongation of the side property line per city standard and plot dnveway perpendicular
to the existing curb and gutter ^
12 Show method of drainage including high points, flowline elevations, storm dram, percent grades
and off-site facilities Appears the lot drains off-site, extend property line and existing contours
to include the entire lot and venfy off-site drainage facilities are adequate
13 Show grading/slopes for building pad, driveway, walkways etc
14 Show complete property boundary data on the site plan, including bearings, distances, and curve
data
15 On the site plan, show and identify all existing surface improvements (curb, gutter, sidewalk,
paving, manholes, inlets, street lights, adjacent driveways, vaults, transformers, etc) along
Argonauta Street at the project frontage
16 On the site plan, show locations of all existing utilities (including watermain, water services, water
meters, sewer mam, sewer laterals, storm dram pipes, etc and their appurtenances) along
Argonauta Street Reference city approved improvement plan drawing numbers of the existing
utilities for references
17 Show the location of the existing water service and proposed water meter with backflow
preventer Indicate the water demand m gallons per day
18 Show the location of the proposed sewer lateral to serve the project Show the invert elevations
to indicate gravity flow
19 Show location of all existing and proposed fire hydrants within 300 feet of the project boundary
20 Vertical control for all design elevations should be based upon the city standard vertical datum,
NGVD 29 (see Engineering Standard Volume 1, Chapter 2) Provide source of the topographic
survey and the vertical datum
21 Meet with the Fire Department to identify the necessary fire protection measures required for
this project (access, fire hydrants, sprinkler system, etc)
22 Tfiis preliminary review does not constitute a complete review of the proposed project and
additional items of concern may be identified upon formal project application submittal
PRE 2018-0008 (DEV2018-0051) - ABEDI MOGHADDAM FAMILY RESIDENCE
May 1, 2018
Page 6
Building:
1 Project may require sewer pump and backfiow prevention valve
Fire:
1 Residential fire sprinklers required
If you would like to schedule a meeting to discuss this letter with the commenting departments, please
contact Paul Dan at the number below You may also contact each department individually as follows
• Planning Division Paul Dan, Associate Planner, at 760-602-4614
• Land Development Engineering Tim Carroll, Project Engineer, at 760-602-2737
Sincerely,
DON NEU, AlCP
City Planner
DN PD dh
Reza Abedi Moghaddam & Effat Fandi, 1 Rue Renior, Coto De Caza, CA 96679
Tim Carroll, Project Engineer
Fire Prevention
HPRM/File Copy
Data Entry