Loading...
HomeMy WebLinkAbout2282 FARADAY AVE; ; CB951368; Permit07/02/96 09:12 Page 1 of 1 B U I L D I N G Job Address: 2282 FARADAY AV Perinit Type: INDUSTRIAL BUILDING Parcel No: 212-061-33-00 Valuation: 7,920 P E R .M I T Suite: Lot#: Permit No: Project No: Development No: S3l}0 07 /02/96 0001 Ol G-·ffJff Construction Type: Occupancy Group: Reference#: Status: Description: 330 SF WAREHOUSE/STORAGE : ISIS PHARMACEUTICALS Appl/Ownr : ISIS PHARMACEUTICALS Applied: Apr/Issue: Entered By: 619-431-2369 APPROVAL IMSP. -~-::;___ DATE 1# CLEA ANCE _____ , CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 CB951368 A9502.0U4 02 101 .. ,0(i V1 ISSUED 09/29/95 07/02/96 RMA i r I @JLW { {)D~ PERMIT APPUCATION PLAN CHECK NO. City of Carlsbad Building Department 2075 Las Palmas Dr., carlsbad, CA 92009 (619) 438-1161 1. PERMIT 'n'PE From Llst 1 (see back) give code of Permit-Type: ____________ _ For Residential Projects Only: From Llst 2 (see back) give Code of Structure-Type: _____________________ _ Net Loss/Gain of Dwelling Units _________________ _ 2. PRQJECI' INFORMATION FOR OFFICE USE ONLY CHECK BELOW IF s0BMl11'Eb: D 2 Energy Cales lil-1" Structural Cales D 2 Soils Report D 1 Addressed Envelope ASSESSOR'S PARCEL EXISTING USE PROPOSED USE DESCRIPTION OF WORK ..STO !lkt/l.:F tJ kl<..._ ££lt;J l{Fc.,, SQ. FT. ~'30 # OF STORIES # OF BEDROOMS # OF BATIIROOMS NAME (last name first)<ol'-v-G.'-~, \'.>VtJe,,v-ASADDRESS 22.cf:>'2. t=:A~A~t\-¥ l'\VE CITY ~~'");'W) STATE CA ZIP CODE q 2...0 0 5S DAY TELEPHONE { (o\ (\) t.f"~ \. '2. '3b9 s. PROPER'IY oWN -,....,. ,,..._ NAME (last name first) \ ~lS t""\-(,~~~'$ ADDRESS '2 2...4i'2.... l-,:,p..e.~'A<-( Ptvc STATE CA-ZIP CODE 2-0o<{, DAY TELEPHONE l -2.. °3G:,""\. NAME (last name first) CITY STATE STATE UC.# ZIP CODE UCENSE CIASS ADDRESS DAY TELEPHONE CITY BUSINESS UC. # DESIGNER NAME (last name hrst) ADDRESS CITY STATE ZIP CODE DAY TELEPHONE STATE UC. # 7. WORRER.s' CXJM.PENsA11oN Workers' Compensation Deciarauon: I hereby afhrm that I have a ceruhcate of consent to self-msure issued by the Director of lndustnal Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POUCY NO. EXPIRATION DATE Cemhcate of Exemption: I cemfy that m the performance of the work for which this permit 1s issued, I shall not employ any person m any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE s. oWNER-BUILDEll bECLARATioN Owner-Builder Declarauon: I hereby affirm that I am exempt from the Contractor's Lcense Law for the followmg reason: g,/ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's Llcense Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's Llcense Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's Llcense Law). D I am exempt under Section _______ Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's Llcense Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, an the sis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjec•!i>-!="'tlVPlica to a vii pe a ty ot more than five hundred dollars [$500]). ' SIGNA: DATE CJ 2, Is the ap 1cant or f ture building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention programJ.Hlder Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? B"YES D NO Is the applicant or future building occup~t required to obtain a permit from the air pollution control district or air quality management district? 0 YES l:l'NO . Is the facility to be constructed within 1,Q.00 feet of the outer boundary of a school site? 0 YES l!l'NO IF ANY OF TIIE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS TIIE APPUCANT HAS MET OR IS MEETING TIIE REQUIREMENTS OF TIIE OFFICE OF EMERGENCY SERVICES AND TIIE AIR POLLUTION OONTROL DISTIUCT. 9. WNS'nlOCl'ION LRNDING AGRNCY I hereby afhrm that there 1s a construction lendmg agency for the performance of the work for which this permit 1s issued (Sec 3097(1) CJV11 Code). LENDER'S NAME LENDER'S ADDRESS lo. APPUCANI CE.ltliFICA:IION I cemly that I have read the apphcauon and state that the above mformation 1s correct. I agree to comply with all City ordmances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I AISO AGREE 10 SAVE INDEMNIFY AND KEEP HARMLFSS TIIE Cl1Y OF CARISBAD AGAINSf ALL IJABIIITIES, JUDGMENTS, OOS1'S AND EXPENSF.S WIIlCH MAY IN ANY WAY ACCRUE AGAINSf SAID Cl1Y IN OONSEQUENCE OF TIIE GRANTING OF TIIIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. 0 CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB951368 FOR 11/01/96 DESCRIPTION: 330 SF WAREHOUSE/STORAGE ISIS PHARMACEUTICALS TYPE: INDUST STE: INSPECTOR AREA PLANCK# CB951368 OCC GRP CONSTR. TYPE Vl LOT: JOB ADDRESS: 2282 FARADAY AV APPLICANT: ISIS PHARMACEUTICALS CONTRACTOR: OWNER: REMARKS: BJN/RON/990-6066 SPECIAL INSTRUCT: PHONE: 619-43}}1-2369 PHONE: PHONE: INSPECTOR --.,---------- TOTAL TIME: --RELATED PERMITS-- CD LVL DESCRIPTION 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical PERMIT# SE930055 FA930018 AS930058 TYPE swow FALARM ASC STATUS ISSUED ISSUED ISSUED ACT COMMENTS &!_ ______ _ t--- ----------------------------------------------------------- ***** INSPECTION HISTORY***** DATE DESCRIPTION 101896 Final Combo ACT. INSP PI TP COMMENTS ND FIRE APPR FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING [FIRE ,J PLANNING U/M WATER PLAN CHECK#: CB951368 PERMIT#: CB951368 PROJECT NAME: 330 SF WAREHOUSE/STORAGE ISIS PHARMACEUTICALS ADORES s : C~§~i-~'FARAhAY]~y __ -J CONTACT PERSON/PHONE#: MW/RON/990-6066 SEWER DIST: CA WATER DIST: CA DATE: 10/18/96 PERMIT TYPE: INDUST By====== ================:=====--=====------= INSPE~ED~ BY: M,.c.£__ INSPECTED BY: INSPECTED BY: COMMENTS: DATE INSPECTED: l~{!L\VtlO APPROVED ~ DISAPPROVED DATE INSPECTED: DATE INSPECTED: APPROVED DISAPPROVED APPROVED DISAPPROVED DATE: 4/30/96 JURISDICTION: Carlsbad PLAN CHECK NO.: 95-1368 EsGil Corporation Professiona[ PCan !R,f.view 'Engineers SET:V PROJECT ADDRESS: 2282 Faraday Avenue D~NT D~ D FIRE D PLAN REVIEWER D FILE PROJECT NAME: Isis Pharmaceticals Hazardous Material Storage Building D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's *********** codes. IZ! The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. -· D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. -· D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans ~re submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to~ [3J Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that th.e plan check has been completed. Person contacted: /) J Date contacted: (by: ) (/Telephone#: IZ! REMARKS: 1.City to verify that there is FM app ov I placard on the storage building. 2. The designer stated that the city will accept the panic ardware across only one-half of the width of the exit door leaves. Please verify. 3. Fire depa ment approval for the emergency chemical system is required. By: David Yao Enclosures: Esgil Corporation D GA D CM D GP D PC log trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92;.]23 + (619) 560-1468 + Fax (619) 560-1576 DATE: 3/21/96 JURISDICTION: Carlsbad PLAN CHECK NO.: 95-1368 EsGil Corporation Professiona{ PCan !f?!.view 'Engineers SET: IV PROJECT ADDRESS: 2282 Faraday Avenue D T D FILE D FIRE VIEWER PROJECT NAME: Isis Pharmaceticals Hazardous Material Storage Building D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's *********** codes. D The plans transmitted herewith will substantially comply with the jurisdiction's********** codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been fax to: Ken Ederington 623-2755 ~ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Telephone #: D REMARKS: By: David Yao Enclosures: Esgil Corporation rgJ GA D CM D GP D PC 3/13 trnsrntl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576 Carlsbad 95-1368 IV 3/21/96 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2282 Faraday Avenue DATE PLAN RECEIVED BY ESGIL CORPORATION: 3/13 REVIEWED BY: David Yao FOREWORD (PLEASE READ): PLAN CHECK NO.: 95-1368 SET: IV DATE RECHECK COMPLETED: 3/21/96 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new sets of prints to: ESGIL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes DNo Carlsbad 95-1368 IV 3/21/96 22. The designer stated that the city will accept the panic hardware across only one- half of the width of the exit door leaves. Please veriify. 31. City to verify that there is FM approval placard on the storage building. 34. Fire department to approve the emergency chemical system comply with the UFC and page 12 of the technical report. If you have any questions regarding these items, please contact David Yao of Esgil Corporation at (619) 560-1468. Thank you. + PLUMBING, MECHANICAL AND ENERGY CORRECTIONS + PLAN REVIEWER: Glen Adamek 33. Provide plans, details, and calculations to show the required exhaust ventilation as per the Technical Report, Section A, Attachment A-2, Item# 15 attached. a) The plans do not show 'mechanical exhaust ventilation system, connected to both primary power supply and emergency/standby power supply.' b) Please make all plan changes in ink. The plans do show the exhaust system outlets from the room within 12 inches of the floor of the building. c) The plans show the supply air inlets into the room near the floor, and not within 12 inches of the ceiling of the building. Please correct. The plans show one of the make-up air inlets is in the wall within 5 foot 2 inches of the existing building, where no openings are perrmitted. d) The plans do not show the required manual ventilation shutoff control is Labeled "VENTILATION SYSTEM EMERGENCY SHUTOFF" e) Please make all plan changes in ink. Correct the exhaust fan discharge clearance to show the bottom of the discharge duct is 1 O feet above adjoining grade, not top of duct opening, as per UMC, Section 11070). f) Detail construction of the exhaust duct extension provided by ISIS. Show the type of material, and thickness and attachment to the building. Note: If you have any questions regarding this plan review list please contact Glen Adamek at (619) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. ' ..... _ ... 1515 PHARMACEUTICALS: 1182 Faraday Avenue, Carlsbad CA 92008 HAZARDOUS MATERIALS & OCCUPANCY CLASSIFICATION ANALYSIS 15. Exhaust Ventilation: • General/Area Exhaust: General/are exhaust ventilation system required as follows: C• ~-e~~~!I\C.~! exhaust _ventilatio~_~y~tem, conr:i_ected to ~9!h prin:1ast po~~~-~P..PlY ~nd <:;--'\__ emergency/standbX power supply. • System to: _ • Operate continuously [supply & exhaust air]. I • Natural ventilation may be used ITTt can oe snownTcfb"En~·ffettive;--------- f~ • Exhaust directly to the outside, without entering other spaces/areas in r· • building. • Make-up air [supply air] to be continuously supplied. • Minimum 1 cfm of exhaust air per square foot of floor area or 6 air changes per hour " ( :.i [whichever is greater). . . . /' ~--·:-_!__Sxhaust ~i: ~.!:!~?.7_!?,~~ed </_=12" _f!~oo~:..- ·-· / ,-a-• Supply air inlets to be locatea <1=12.,,.oelow ceiling. -------- t _d ___ , // • -• Supply and exhaust air inlets/outlets to be so arranged to provide cross-ventilation . .,_ .·;'.; / • Exhaust ducts discharging to the atmosphere to terminate >/=3' from property lines ·,!' and building openings. /--.-Mc;i.DJ.H~I ventilation shutoff cpntrol: ) _ • __ J-:9.9at~~-L:J!s.t~~ -~o~~ -~9j~~e_nt_to ac~~_§s_into room. .._ '--• Labeled "VENTILATION SYSTEM EMERGENCY SHUTOFF". :""'. • Local Exhaust: Local exhaust venfiTafion systeitfto·capture·fumes;-mis-ts or vapors at the -~ I -t-~ • Break-glassJypB switch . :-·· point of generation [exhausted enclosures, fume hoods, "elephant" exhaust, etc.) required , for the following, unless it can be demonstrated that there are no harmful fumes, mists or vapors: .,'t • Open system use, dispensing, mixing for materials having a health, flammability or reactivity rating of 3 or 4. • Closed system use, dispensing, mixing if "closed systems" are open as part of their normal operation for materials having a health, flammability or reactivity rating of 3 or 4. • Exhaust Vent Discharge Location: • Flammable Fumes, Vapors, Dusts: • >/=30' from property lines. • >/=1 0' from openings into building. • >/=6' from exterior walls/roofs. • >/=30' from combustible walls or openings into building in direction of exhaust. ~ • >/=1 O' above adjoining grade. · NOTE: Flammable vapors/fumes = concentration of flammable constituents in air >10% of lowe·r flammable limit [LFL). • Other: • >/=10' from property lines, openings into building & above adjoining grade. • >/=3' from exterior walls/roofs. 1991 Codes: UBC 905; UFC 79.104, 79.203; UMC 1102, 1105, 1106, 1107 1994 Codes: UBC 1202.2.3; UFC 7902.5.11.4, 8003.1.8; UMC 502, 504, 505, 507, 609.10 Hazardous Materials -"H-2/H-7" Occupancy Requirements Eriksen-Rattan Associates Inc. 8/31195 • Page 11 of 13 i. ! I i. i . : ... _ ,, I WNIIMIN d iii 1515 PHARMACEUTICALS: 1182 Faraday Avenue, Carlsbad CA 92008 HAZARDOUS MATERIALS & OCCUPANCY CLASSIFICATION ANALYSIS 16. Emergency/Standby Power System: Required to automatically supply all required electrical systems when normal power is interrupted for: . • Mechanical exhaust ventilation system. • Emergency chemical alarm system. • Sprinkler system waterflow and valve tamper. • Exit illumination. • Exit sign illumination. • Smoke detection system. • An emergency power source is described by the National Electrical Code as a source of power that, in the event of failure of the normal supply, is available within 10 seconds of normal power failure. NOTE: Required, only for "H-7" areas and "H-2/H-3" areas also classified as "H-7" areas -otherwise, standby power source is acceptable. e A standby power source is described by the National Electrical Code as a source of power that, in the event of failure of the normal supply, is available within 60 seconds of normal power failure. --· approved by the local Building Department and Fire Department: ) e The emergency/standby power system may consist of one [1] or more of the following as • On-site storage batteries. • On-site generator set. L ·: On-site uninterruptible power supply [UPS system]. Separate electrical service. Connection ahead of service disconnect. 1991 Codes: UBC 902(g), 902{h); UFC 80.301{s) 1994 Codes: uac 307.2; UFC 8003.1.13 17. Emergency Chemical Alarm System: • Approved manual emergency alarm system in "H" portion of building. • Signal i!1itiating device to be located outside each interior exit door of each "H" area. • Activation of signal initiating device to sound local alarm to alert personnel of an emergency situation involving hazardous materials. • System to be supervised by an approved central, proprietary or remote station service or at constantly attended on-site location. • 2 power supplies -normal building power and emergency/standby power. 1991 Codes: UFC 80.301(u) 1994 Codes: UFC 8003.1.15 18. Explosion Control -Class 1-B Flammable Liquids: Explosion control not required - continuous general/area and local mechanical exhaust ventilation required -see Items 14 & 15 above. 1991 Codes: 1994 Codes: uac 910, Chapter 23; UFC 79.104, 80.301(q) UBC 307.10; UFC 7902.1.5, 8003.1.12 Hazardous Materials -"H-2/H-7" Occupancy Requirements Eriksen-Rattan Associates Inc. 8/31/95 -Page 12 of 13 q ' ; I I ; . i' i I I ... DATE: 12/27/95 JURISDICTION: Carlsbad PLAN CHECK NO.: 95-1368 EsGil Corporation Professiona{ PCan ~view 'Engineers SET: III PROJECT ADDRESS: 2282 Faraday Avenue D FIRE N REVIEWER D FILE PROJECT NAME: Isis Pharmaceticals Hazardous Material Storage Building D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corpqration until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Douglas Silveria 2282 Faraday Avenue Carlsbad CA 92008 ~ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Telephone #: D REMARKS: By: David Yao Enclosures: Esgil Corporation ~ GA DCM D GP D PC 12/18 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576 Carlsbad 95-1368 III 12/27/95 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2282 Faraday Avenue DATE PLAN RECEIVED BY ESGIL CORPORATION: 12/18 REVIEWED BY: David Yao FOREWORD (PLEASE READ): PLAN CHECK NO.: 95-1368 SET: III DATE RECHECK COMPLETED: 12/27/95 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new sets of prints to: ESGIL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes DNo '· .... Carlsbad 95-1368 III 12/27/95 18. Clearly identify location and hourly fire-resistive rating of exterior walls on the plans. Provide construction details of the walls with ICBO or UL number.Section 1706. Provide ICBO or UL number for the 2hr exterior wall. The letter from Factory Mutual Research(3V1A4.AF) did not show how the walls were constructed? Did not indicating the wall was 2hr? Did not indicating the test of the wall comply with UBC Standard? It appears there are more pages to the Factory Mutual Research report. Please provide the complete report. 22. Exit doors from Group A,E,H-I,H-2,H-3 and I occupancies shall not be provided with a latch or lock unless it is panic hardware. Chapter 33. Provide panic hardware for the doors or check with city. 23. Regardless of occupant load, a floor or landing not more than 1 inch (1/2-inch if disabled access is required) below the threshold is required on each side of an exit door. Section 3304 (i). Provide detail to show the thresholds are 1/2 inch or check with city. 27. Provide construction detail and calculation to justify the tie down provided comply with the tension and shear force shown on sheet 8 of the calculations. The anchorage detail for the storage shed shall be incorporated into the final approval plan or check with city to accept the separate 81 /2 x 11 sheet as an approved plan. 31. Provide state approval number for the module building or ICBO approval fabricator for the storage building. The prefab building shall have approval from ICBO or other agency. The letter from Factory Mutual did not indicating which agency inspect the construction of the storage building. It shall be inspected be an approved agency. Or check with city. 34. Fire department to approve the emergency chemical alarm system comply with the UFC and page 12 of the technical report. See attached. If you have any questions regarding these items, please contact David Yao of Esgil Corporation at (619) 560-1468. Thank you. Carlsbad 95-1368 III 12/27/95 PLUMBING, MECHANICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Glen Adamek 32. Provide calculations for each containment area as per UBC, Section 902(e). Clea~ly 'show the largest container to be in the building. Also, clearly show the capacity of the building secondary containment system within the building. 33. Provide plans, details, and calculations to show the required exhaust ventilation as per the Technical Report, Section A, Attachment A-2, Item# 15 attached. a) The plans do not show 'mechanical exhaust ventilation system, connected to both primary power supply and emergency/standby power supply.' b) The plans do show the exhaust system outlets from the room within 12 inches of the floor of the building. c) The plans show the supply air inlets into the room near the floor, and not within 12 inches of the ceiling of the building. d) The plans do not show the required manual ventilation shutoff control: i) Located outside the room adjacent to access into the room. ii) Break-glass type switch. iii) Labeled "VENTILATION SYSTEM EMERGENCY SHUTOFF' e) Correct the exhaust fan discharge clearance to show the bottom of the discharge duct is 10 feet above adjoining grade, not top of duct opening, as per UMC, Section 1107G). Also detail construction of the exhaust duct extension. Note: If you have any questions regarding this plan review list please contact Glen Adamek at (619) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. 1515 PHARMACEUTICALS: 1182 Faraday Avenue, Carlsbad CA 92008 HAZARDOUS MATERIALS & OCCUPANCY CLASSIFICATION ANALYSIS 15. Exhaust Ventilation: • General/Area Exhaust: General/are exhaust ventilation system required as follows: ~· ~~~b.~~~§l e_xhaust _vent\latio~ system, connected to both primary power sue_e!Y. ~nd ~i-'""\_ emergency/standbl power supply. / • Natural ventilation may be usecl if it can15esfiowrl"fo oe"effectivr---,- • System to: • Operate continuously [supply & exhaust air]. lx' • Exhaust directly to the outside, without entering other spaces/areas in f · • building. . • Make-up air [supply air] to be continuously supplied. • Minimum 1 cfm of exhaust air per square foot of floor area or 6 air changes per hour [whichever is greater]. ;' -4····-:. /~-/ : - Exhaust air outlets to be located </=12" from floor. Supply air inlets to be'Iocatecf<T='12'"13elowcei!ing."......,=-~ Supply and exhaust air inlets/outlets to be so arranged to provide cross-ventilation. Exhaust ducts discharging to the atmosphere to terminate >/=3' from property lines and building openings. /. • Manual ventilation shutoff control: }--_ ) _• _ Located o~t~de -~o_o_~ -~-~j?!~~_nt !~ ~~S:-~§~ into room. -o .1 -t--i • Break-glass type switch. ~ I "-• Labeled "VENTILATION SYSTEM EMERGENCY SHUTOFF". ~ • Local Exhaust: Local exhaust venfilabon systerrno--capture·fumes;-mis-ts or vapors at the 'l point of generation [exhausted enclosures, fume hoods, "elephant" exhaust, etc.] required for the following, unless it can be demonstrated that there are no harmful fumes, mists or vapors: ' '• • Open system use, dispensing, mixing for materials having a health, flammability or reactivity rating of 3 or 4. • Closed system use, dispensing, mixing if "closed systems" are open as part of their normal operation for materials having a health, flammability or reactivity rating of 3 or ~ . • Exhaust Vent Discharge Location: • Flammable Fumes, Vapors, Dusts: • >/=30' from property lines. • >/=1 0' from openings into building. • >/=6' from exterior walls/roofs. • >/=30' from combustible walls or openings into building in direction of exhaust. ~ • >/=1 O' above adjoining grade. NOTE: Flamrnable vapors/fumes -concentration of flammable constituents in air > 10% of lowe·r flammable limit [LFL]. • Other: • >/=10' from property lines, openings into building & above adjoining grade. • >/=3' from exterior walls/roofs. 1991 Codes: UBC 905; UFC 79.104, 79.203; UMC 1102, 1105, 1106, 1107 1994 Codes: UBC 1202.2.3; UFC 7902.5.11.4, 8003.1.8; UMC 502, 504, 505, 507, 609.10 Hazardous Materials -"H-2/H-7" Occupancy Requirements Eriksen-Rattan Associates Inc. 8/31/95 -Page 11 of 13 ' . . ' i j' I. I ! 1: l l I I ; l; l l NfMtttMtH@SttdffllE~*!-~'"*'' ISIS PHARMACEUTICALS: 1182 Faraday Avenue, Carlsbad CA 92008 HAZARDOUS MATERIALS & OCCUPANCY CLASSIFICATION ANALYSIS 16. Emergency/Standby Power System: Required to automatically supply all required electrical systems when normal power is interrupted for: • • Mechanical exhaust ventilation system. • Emergency chemical alarm system. • Sprinkler system waterflow and valve tamper. • Exit illumination. • Exit sign illumination. • Smoke detection system. • An emergency power source is described by the National Electrical Code as a source of power that, in the event of failure of the normal supply, is available within 1 o seconds of normal power failure. NOTE: Required, only for "H-7" areas and "H-2/H-3" areas also classified as "H-7" areas -otherwise, standby power source is acceptable. • A standby power source is described by the National Electrical Code as a source of power that, in the event of failure of the normal supply, is available within 60 seconds of normal power failure. • The emergency/standby power system may consist of one [1] or more of the following as approved by the local Building Department and Fire Department: • On-site storage batteries. • On-site generator set. • On-site uninterruptible power supply [UPS system]. • Separate electrical service. --• Connection ahead of service disconnect. 1991 Codes: UBC 902(g), 902(h); UFC 80.301(s) 1994 Codes: UBC 307.2; UFC 8003.1.13 17. Emergency Chemical Alarm System: • Approved manual emergency alarm system in "H" portion of building. • Signal i[litiating device to be located outside each interior exit door of each "H" area. • Activation of signal initiating device to sound local alarm to alert personnel of an emergency situation involving hazardous materials. • System to be supervised by an approved central, proprietary or remote station service or at constantly attended on-site location. • 2 power supplies -normal building power and emergency/standby power. 1991 Codes: UFC 80.301(u) 1994 Codes: UFC 8003.1.15 18. Explosion Control -Class 1-8 Flammable Liquids: Explosion control not required - continuous general/area and local mechanical exhaust ventilation required -see Items 14 & 15 above. 1991 Codes: 1994 Codes: UBC 910, Chapter 23; UFC 79.104, 80.301(q) UBC 307.10; UFC 7902.1.5, 8003.1.12 Hazardous Materials -"H-2/H-7" Occupancy Requirements Eriksen-Rattan Associates Inc. 8/31/95 -Page 12 of 13 eaees a, q i . l .l· EsGil Corporation Professiona{ PCan !R.f.View 'Engineers D APPLICANT ~ DFIRE DATE: 11/2/95 JURISDICTION: Carlsbad PLAN CHECK NO.: 95-1368 ~NREVIEWER D FILE SET: II PROJECT ADDRESS: 2280 Faraday Avenue PROJECT NAME: Isis Pharmaceticals Hazardous Material Storage Building D The plans transmitted herewith have been cofrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. !ZI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. i:gJ The applicant's copy of the check list has been sent to: Douglas Silveria 2282 Faraday Avenue Carlsbad CA 92008 i:gJ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Telephone#: D REMARKS: By: David Yao Enclosures: Esgil Corporation ~ GA DCM D GP D PC 10/24 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576 Carlsbad 95-1368 II 11/2/95 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2280 Faraday Avenue DATE PLAN RECEIVED BY ESGIL CORPORATION: 10/24 REVIEWED BY: David Yao FOREWORD (PLEASE READ): PLAN CHECK NO.: 95-1368 SET: II DATE RECHECK COMPLETED: 11/2/95 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineer_ing Department or other departments. The following items need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A Please make all corrections on the original tracings and submit two new sets of prints to: ESGIL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any. changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes DNo Carlsbad 95-1368 II 11/2/95 3. All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. Business and Professions Code. The sheets AO and A 1.0 shall be signed and sealed by the architect or engineer. 8. Clearly designate on the site plan existing buildings to remain, existing buildings to be demolished, buildings to be constructed under this permit and any proposed future buildings. The note for the storage shall be proposed H2 building.(not future building) 13. The exterior walls less than 5, 10,20 feet to a property line or an assumed property line, shall be 4,2, 1 fire-rated construction. Section 9-C. a)Since the assumed property line is next to the exterior wall of the existing building, the exterior wall of the existing building shall be 2hr construction. Please provide construction detail for the wall to justify the 2hr construction. b)The exterior wall of the H2 building is 5'-2" from the assumed property line. The wall shall be 2 hr construction. Provide UL or ICBO approval number to justify the assembly of the wall is 2hr construction. 14. Exterior walls shall have a 30 inch parapet when less than 20 feet to a property line or an assumed property line. The uppermost 18" of such parapets shall be noncombustible. (see exceptions, Section 1710. ) The exterior wall of the existing building shall have parapet. Show 18 inches parapet for the existing building on the plan. 15, The exterior wall shall have protected openings (3/4 hour) when closer than 20 feet to a property line or an assumed property line. Section The air vent for the H2 building next to the existing building shall be 3/4 hr. Please note on the plan. 16. The exterior walls shall have no openings when closer than 5 feet to a property line or an assumed property line. Openings include windows, doors, scuppers, vents, etc. Section The exterior wall next to the H2 building for the existing building can not have any opening.(include mechanical opening) Note or show on the plan Carlsbad 95-1368 II 11/2/95 18. Clearly identify location and hourly fire-resistive rating of exterior walls on the plans. Provide construction details of the walls with ICBO or UL number.Section 1706. Provide ICBO or UL number for the 2hr exterior wall. 22. Exit doors from Group A,E,H-l,H-2,H-3 and I occupancies shall not be provided with a latch or lock unless it is panic hardware. Chapter 33. Provide panic hardware for the doors.(! do not understand the term slap latch) 23. Regardless of occupant load, a floor or landing not more than 1 inch (1/2-inch if disabled access is required) below the threshold is required on each side of an exit door. Section 3304 (i). Provide detail to show there are landing on both sides of the doors and thresholds are 1/2 inch. ·· 24. Exit signs are required whenever two exits are required. Show all required exit sign locations. Section 3314 (a). Provide exit signs for the exit doors. (exception 1 usually for the main glass door) Or check with city. 25. Show two sources of power for the lamps at exit signs. Section 3314(d). 27. Provide construction detail and calculation to.justify the tie down provided comply with the tension and shear force shown on sheet 8 of the calculations. Sheet 8 of the calculation indicating that provide tie down at each corner. The plan must provide adequate tie down to resist the force at sheet 8 of the calculation. 30. Provide note and details on the plans to show compliance with the enclosed Disabled Access Review List. Disabled access requirements may be more restrictive than the UBC.(Show detail of the path of travel from the parking to the storage building and the bathrooms serve the storage building comply with the handicapped access requirements. Or check with city to provide the note on the plan that from the handicapped access parkings to the new storage building and the bathrooms serve the storage building is comply with all the current handicapped access requirements.) Show the details for the handicapped access to the storage building. Or check with city. Carlsbad 95-1368 II 11/2/95 31. Provide state approval number for the module building or ICBO approval fabricator for the storage building. The prefab building shall have approval from ICBO or other agency. Or check with city. · 34. Provide detail plan to show the emergency power and emergency chemical alarm systems comply with page 12 of the report. * The plan check 95-1394 did not show the detail for the chemical alarm system comply with page 12 of the report. Note on the electrical plan that all conduit penetrating the storage building will have seals per NEC 501-5 If you have any questions regarding these items, please contact David Yao of Esgil Corporation at (619) 560-1468. Thank you. · PLUMBING, MECHANICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Glen Adamek 32. Provide calculations for each containment area as per UBC, Section 902(e). 33. Provide plans, details, and calculations to show the required exhaust ventilation as per the Technical Report, Section A, Attachment A-2, Item # 15. A. Correct the exhaust discharge clearances as per UMC, Section 11070). B. Correct the make-up air inlet location. Openings are not allowed in the property line wall. C. Provide calculations for the required ventilation rates. Note: If you have any questions regarding this plan review list please contact Glen Adamek at (619) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. DATE: 10/12/95 JURISDICTION: Carlsbad PLAN CHECK NO.: 95-1368 EsGil Corporation Professiona( PCan !R,f!view 'Engineers SET: I PROJECT ADDRESS: 2280 Faraday Avenue ~~CANT ~ D Fl RE D PLAN REVIEWER D FILE PROJECT NAME: Isis Pharmaceuticals Hazardous Materiald Storage Building D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Douglas Silveira 2282 Faraday Avenue Carlsbad CA 92008 ~ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Telephone#: D REMARKS: By: David Yao Enclosures: Esgil Corporation ~ GA ~ CM D GP D PC 10/2 trnsrntl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576 Carlsbad 95-1368 10/12/95 PLAN REVIEW CORRECTION LIST COMMERCIAL JURISDICTION: Carlsbad PLAN CHECK NO.: 95-1368 OCCUPANCY: H-2,7 USE: hazardous materials storage TYPE OF CONSTRUCTION: V-N ALLOWABLE FLOOR AREA: 2500 SF SPRINKLERS?: Y REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 10/12/95 FOREWORD (PLEASE READ): ACTUAL AREA: 370 SF STORIES: 1 HEIGHT: ..... 9 feet OCCUPANT LOAD: 1 DATE PLANS RECEIVED BY ESGIL CORPORATION: 10/2 PLAN REVIEWER: David Yao This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1991 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. LIST NO. 22, GENERAL COMMERCIAL WITHOUT ENERGY OR POLICY SUPPLEMENTS (1991 UBC) comforw.dot Carlsbad 95-1368 10/12/95 • PLANS 1. Please make all corrections on the original tracings and submit two new sets of prints, to: Esgil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, (619) 560-1468. • GENERAL 2. Provide the site address and a vicinity sketch on the Title Sheet. 3. All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans .are signed. Business and Professions Code. 4. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: Occupancy Group Description of Use Type of Construction Sprinklers: Yes or No Stories Height Floor Area 5. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1991 UBC, UMC and UPC and 1990 NEC. • SITE PLAN 6. Provide a fully dimensioned site plan drawn to scale. Show north arrow, property lines, easements, streets, existing and proposed buildings and structures. 7. Provide a statement on the site plan stating: "All property lines, easements and buildings, both existing and proposed, are shown on this site plan". 8. Clearly designate on the site plan existing buildings to remain, existing buildings to be demolished, buildings to be constructed under this permit and any proposed future buildings. 9. Clearly designate any side yards used to justify increases in allowable area based on Section 506.(if applicable) Carlsbad 95-1368 10/12/95 10. Clearly dimension building setbacks from property lines, street centerlines, and from all adjacent buildings and structures on the site plan. 11. Show dimensioned parking layout including any required disabled access spaces. • LOCATION ON PROPERTY 12. When a new building is to be erected on the same property as an existing building, the location of the assumed property line with relation to the existing building shall be such that the exterior wall and opening protection of the existing building meet the criteria of Table 5-A and Part IV. Section 504 13. The exterior walls less than 5, 10,20 feet to a property line or an assumed property line, shall be 4,2, 1 fire-rated construction. Section 9-C. 14. Exterior walls shall have a 30 inch parapet when less than 20 feet to a property line or an assumed property line. The uppermost 18" of such parapets shall be noncombustible. (see exceptions, Section 1710. ) 15. The exterior wall shall have protected openings (3/4 hour) when closer than 20 feet to a property line or an assumed property line. Section 16. The exterior walls shall have no openings when closer than 5 feet to a property line or an assumed property line. Openings include windows, doors, scuppers, vents, etc. Section • BUILDING AREA 17. When a building has more than one occupancy, the area shall be such that the sum of the ratios of the actual area divided by the allowable area for each occupancy shall not exceed one. Section 503 (a).(if applicable) • FIRE-RESISTIVE CONSTRUCTION 18. Clearly identify location and hourly fire-resistive rating of exterior walls on the plans. Provide construction details of the walls with ICBO or UL number.Section 1706. • OCCUPANCY SEPARATION 19. A 2-hour occupancy separation is required between B-2 occupancy and the H-2 occupancy. Table 5-B, Section 503(d). (See exceptions in Section 503)(if applicable) Carlsbad 95-1368 10/12/95 20. Provide 2 -hour fire-resistive door assemblies in the2-hour occupancy separation. Section 503 (c).(if applicable) • EXITS 21. Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge." Section 3304(c). 22. Exit doors from Group A,E,H-l,H-2,H-3 and I occupancies shall not be provided with a latch or lock unless it is panic hardware. Chapter 33. 23. Regardless of occupant load, a floor or landing not more than 1 inch (1/2-inch if disabled access is required) below the threshold is required on each side of an exit door. Section 3304 (i). • EXIT SIGNS 24. Exit signs are required whenever two exits are required. Show all required exit sign locations. Section 3314 (a). 25. Show two sources of power for the lamps at exit signs. Section 3314(d). • FRAMING 26. Note on the plans that "all weather-exposed surfaces shall have a weather-resistive barrier to protect the interior wall covering and that exterior openings shall be flashed in such a manner as to make them weatherproof'. Section 1708. 27. Provide construction detail and calculation to justify the tie down provided comply with the tension and shear force shown on sheet 8 of the calculations. 28. Door lintel sizes and locations shall be clearly identified on the plan.(sheet 23 of the calculation.) 29. Sheet 15 of the calculation indicating the floor support members have Sx = 3.77 in3 Ix= 8.18 in4 A=1.94 in2• The floor framing shows the floor supporting members are C 4x5.4 which properties are less than the calculation shown. Please check. • TITLE 24 DISABLED ACCESS 30. Provide note and details on the plans to show compliance with the enclosed Disabled Access Review List. Disabled access requirements may be more restrictive than the UBC.(Show detail of the path of travel from the parking to the storage building and the bathrooms serve the storage building comply with the Carlsbad 95-1368 10/12/95 handicapped access requirements. Or check with city to provide the note on the plan that from the handicapped access parkings to the new storage building and the bathrooms serve the storage building is comply with all the current handicapped access requirements.) • ADDITIONAL 31. Provide state approval number for the module building or ICBO approval fabricator for the storage building. 32. Is the H-2 storage building should has spill control and containment? If yes, provide detail to show how to comply with the requirement. 33. Provide mechanical plan to show the exhaust ventilation complies with the report.(page 11) 34. Provide detail plan to show the emergency power and emergency chemical alarm systems comply with page 12 of the report. 35; Is the treatment system-corrosives,toxics required for the storage building? If yes, provide detail.(page 13 of the report ) 36. Provide a panel schedule for the panel feeding the new 125 Amp load center. Show existing and new loads. 37. Note on the plan that all wiring, fixture, switches and receptacles inside the hazardous storage building must be Class 1 Division 1. 38. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 39. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: D Yes D No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. Carlsbad 95-1368 10/12/95 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 95-1368 PREPARED BY: David Yao DATE: 10/12/95 BUILDING ADDRESS: 2280 Faraday Avenue BUILDING OCCUPANCY: H-2, 7 TYPE OF CONSTRUCTION: V-N BUILDING PORTION BUILDING AREA (sq. ft.) hazardous materials storage building Air Conditioning Fire Sprinklers TOTAL VALUE UBC Building Permit Fee: UBC Plan Check Fee: Comments: VALUATION MULTIPLIER p~r permit application VALUE 7920 $ 99.0 $ 64.35 ($) Sheet 1 of 1 valuefee.dot EHRLICH ARCHITECTURE ENGINEERING PLANNING INTERIOR DESIGN FROM: ~ N CoN H:;~ PLEASE FIND: $ ATTACHED ROMINGER TRANSMITTAL JOB NO.: C4 N N l r"f" DATE: I. 't' 'f to Pf tazvo-s, kV6:f !::e.J I zl? PH2<f:-:M:l!Pf½d tt fi'ab) THE FOLLOWING: _ DRAWINGS FORYOUR: _ APPROVAL _ U~ER~PARATE COVER · :f. F~l 141> e, .,. ~e, ~ 'f _ SPECIFICATIONS _ SAMPLES _$ REVIEW & COMMENT _ INFORMATION .. S_H!=ETS INCLUDING THIS COVER COPIES DATE I REMARKS: cc: C Cl . 6363 GREENWJCH DRIVE SUITE260 SANO/EGO. CA 92122 !619) 623-1300 OS Ai TO.': ~ CORRESPONDENCE _ AS REQUESTED DESCRIPTION ~Pe~* n, fk¥tl t:--~ c,~,r,1 t:.,M MS1::1:("!? :Qt?<f t+:f«µ I l?:::f%: c--1 T1 t:,f: vfl \ht2i!!Q Mf Hvi¥k Cl a '.'El:PoRr 8EA(.1' EHRLICH-ROMINGER ARCHITECTURE ENGINEERING PLANNING INTERIOR DESIGN 1· 'i ·'f(, ft.,e,: ,.,. ,~~11.~ ~ ~ f>~~ ,1a1e,,,-. v-..., .. ~ ,~ \ -....,..,.__ ... ~,,,..-._ ___________________ ,-.aw= ________________ ~--- Ttte,, <A-e>c;., . ~t.U,,_,.. pprrJic--~~ / LAlt-t~c-4t Df'e,,-J,E, kr ~ '{?) ft, fo"t,al'>fit t(Jf' f'P-H,"'14fl4 I fOa---tt-• ~ ~Jet,Jc:,aM. ttcNJ&V&+-.1 nte--u.~ IJ(\,Alte> \2-t4,-C).l....,. lOO ....... sf Of" Bi,( fl.4_., ue ~ tii,,. ~ ~ • t tit '" f~~~1"t ~~ t'P of T+t,6., oft tJlO t.J ~ \1' I~ Wt>~ ~..,_I.A-& 't'o ~e,.. Tt't'e--t,ca,o,-& ~,tJ6, ~f.,.J ~f'-'•1\le,(...'f 1."'d~ ~ple,p ~ J ~ ~tJ& -ore., ,-~ 't'"f ~~l~N "~-r~ ~~e 1\nl:,, E;)CflA'•\otJ ~ v~c-~. ~ .... I 1't'e,, ..-~P'\lvb ~\/W'~ · &,)Cl..,l A:l~v--,C,""f'~ \...--.V~ ') ,~ 1tre,, 4p.l(Pe,+f /'-ff~~,~ •f~\Pl~ ~t--' ~ r,e+L<'",f.J 'Pf&-"~ \ r-JCP• "i-l ~ ~ \ ~fl a. • ~: 1"~ ~'{• 1-l\) +~~ p....,-~L«..,-1, >NP ~ ( "-'t ,. ~"' ) ~ ""~ 9'4t'W , Nd,-S, wt ~ ,,_, ~~ 'LO f'~ 0"1.6JtN;,d., (~ A&<Z...) l<~t-h.~~ ~IA&1'->P-1NTCS.. 1'~.... l:JJ ~...,_,,-,s. GIMPMC.e.- -nre-, ed'f'-\4-~N 00 ~~ • EHRLICH-ROMINGER ARCHITECTURE ENrJ/NEERING PL.ANNING INTERIOR DESIGN ••. ~ (._<f'.JJ4V~ -~~~~~I:--·~·· ~~~-· . . • '!",. .: " '.~. : ~ "'1"'~ • tr'r.:P. .f'fl,,,tl1W,. l,.,,O~ )INO,~ • RCV BY:. 1- .. .... \ -~--~ ~ 91:42 U': I , . . · 1. vfrl4;t ~.;17 96- i . ·,., -.· .. I ,-'.,. •,-I . :.. '• f I·.~. . ,, .. ..,,,, ..... 18785 ' ' I ....... 9-9G ; 9: 2!3AM : . • t . ~ CCITf ECM-+ ,. , i . i ! ,. . I , I i !· . ' . , . :), i . I ! i . 62:32755:# 2 ----·"': '. ! .. .. ' . I' ...... · . ., • • • • . t , .... RCV BY: ; ! • 1 I -• I ·-- ':I ... ··• ,a 1i .. a"" •· 1 ., .. !! J I • _.., \ • -• I s... . t! i i ii i I . • -. ' . .. I l i ! : • t I I I · 9:24AM: l-9-96 · • . .. ---.. __ : • • • I . I ,. I .. .. ii . -.. -I ~ I -\ ' ' : -·-. f . I ' . ' . ' • 6232755:# 3 ..,. * IO lf.l t--~ ~ ~ '° t :::;;: u !.1l \: u U :;;:;:: ...:: ..i,, C'l ~ (D o;, I 0) I .... >-'° ~ 1.Bepnrtmettt nf iJuilbiug anb ~afety Gt.ertifitate nt J\.pprouul FABRICATOR'S LlCENSE NO. 1409 THIS CERTIFIES THAT SAFETY STORAGE. INC.. LOCATED AT· . 2301 BERT' ORI.VE. HOLLIS'lER. CALIFORNIA 95023 --···-ts-A-P-Ptt-e-v-B··D··· -n·y···-T-H-E ·-o--E--P--:A·-n-r M-t-N-T -oF B"u-1-r;-01 N·o····A-,ro-···sirF·E·T y--u-N1YER-·---·-····--··-··· .... ···- T H '£ PROVISIONS ·or SECTION 96.203 O.F THE LOS ANGELES MUN1Cl-PAL CODE AS A 'PYPE I FABRICATOR OF LJ:GHT WIGHT STEEL (I,.WS). 0DAT.E: March JO. 1994 ------··-DHD'M.-RENEWAr.---APR-LL-1'-r------------~ .• 1/ / • r • £~ ---------~-m ~ GEKE1u1---... fflfS C&RtlFICAtic°ts 'J1f! PBO.PERr'/ or nm CITY OF LOS AHGE!.ES AND 1V. 'i .Bli llEVOXED fOll ANY OF THE CAUS£S SF.T f'OHTJf IN AB1JCtE 9, CH'Af'!ER 9 OF r.AMC. cS ._Z(I JIU,,9 RCV BX.: .. 1-9-96: 9:24AM; . _cc I TT ECM-> 6~32.7.!'55: # 5 -· -· I Dt:M--~ENT Of' BUILCIIN4 ~D S,41,..EtJ:Y 4011, 'I' MAI.I. LO$ ANCit:U: CA Gcx)l2-t66!l I i I i d:tTV OF Los ANGELES CALIPOHNIA WAflR~ 1/, 0'Bl!1£N ()t!N!l'l"'r.. IIAl\f"Ci,l;lt 'TIMOTMV 'f'AYI.OR EKICIJTIVlt Oi"l"lc:1:11 SaJ~ty Storage. Inc. RJ:SEARCH REPORT: RR 25189 ;lo1t:;,gt~s023 j Expires~ May 1. l 995 Attl: Kenneth Wilkins (40~) 637~595S . I i 1 GiRAL APPROVAL· Safety Srorage Buildings' W111erproof Panel,. DE AILS Sat: ty Storage, Inc. wea~rproof panels are welded lO gage chick sheet steel used in prcirbricated SlOrage containers . . Th•I nppm••I ;, ,ubjec, ,o d1e rouowini: condi1io11,,,, I • • • l. 1~ The fabricntion of the; weatherproof panel!! slmll be !lone in the shop of a licen.1ed Type · I Fabricator approved· by the City of Los Angeles Building Dupar1me.nt. DIS USSION The lapprov~l is based on wai.r pelll:'tration tests in nccordnnci, wirh /\STM ES14·90 modified to 1sTM E:\31-86. . This! general approval of an equivalent alternate to the Code .is only valid where an engineer andlbr inspector or this Depa~ment has detennined thaa all condition:; M th'is npproval ru.ive been met [in t~e project in which-it fs to be used. RR 25189 AN t"OUA~ IIMPLOJ.eNT OPPORTUMTY -APFIFfM P.1p,· I nl2 : . .A TIVE ACTION £MPL.0Yi!!a 1-9-96 9:25AM CCITT ECM-. 6232755;# 6 RCV BY: ' j· . Sa.f1)' Storage, Inc_ RE: [ . Saf ery Storage Buildid/ls' Weaterproof Panels ~ I ! Adclt'essee to whom this Restarch Report is isi.ue<.I is re~ponsihli: Ii.,,· providing copies or it. complete wisb i!D.l' altachm;~ts indlcnted, to architi:cts, engin~rs :md builders using items apprpvcd herein in design or ~onstruction which must he npproveu fly Oermrtmcnt of Building and ~atety Engineers and Inspectors. ! . ! all,.J. ·.rJ~l IBRAHIM HABASHI. Chief- Re~arch am.l Development division I APPttOVEO BY. I . I I . ' i/' ,.. ' ;· ' :1, ; ... ·~//. / .,.,.... .... ",' I IP ,· ,• • ~ 1/ ,·, • • / •l/',1.~_.. .~1, :, ,, ...... ~. ~. ,~···~·/·· .,.,, .,.~,· K. ~-OBERT AYERS, Chief: Res urce· Management Bureau ' . ; I ~ KBT:¥J. RllJ.Sl~9 'k3.2ll.1N 211211,t I I i )' I I' ., j RR ~5189 P11g1,.1 2.<>f 2 TOTAL P.06 ._,I . .I L '::i!DVd t:l111LICH • oi=0 N NorivorNnw:woo R a M , " " c 11 so=·· <a::i!.M) 96 • so ·adv ARCHITECTURE ENGINEERING PLANNING INTERIOR DESIGN TRANSMITTAL TO; ~~\ L,. ATTN: · · ·· t::>A-V t t.? Y kO PROJECT: l~l~ f~~n~'-4~ JOB NO.: f <--.l<N c-~ ,.._,. ei ~ -l~ h~ FROM: ~Jk'tH""P-( tJ C<:"/ N N 1 !f°F DATE: t.f · ~ · 1 ~ PLEASE FIND: ...± AlTACHED _ UNDER SEPARATE CCV!R -4': FAX S, G,IJ ..., I ":> 1 Ut ..¥2.. SHEETS INCLUDING THIS COVER COPIES l DATE THE FOi.i.OWiNG: _ DRAWINGS _ SPECIFICATIONS _,_ SAMPLES .i: CORRESPONDENCE DESCRIPTION f~F"'?:JH? ;<f...-t!f::!'J.kf ,e, l{ FORYOUR: _ APPROVAL Jk-R&VIEW &COMM!NT _ INFORMATION· _ AS REQUESTED l\ ,, REMARKS: r~\J\ "'~ t:,")('f"~rJ~l""' f \..V-r·N~o1,1 ~p..,, Fe:,..... T~ 1/'J{t..-l ..... T~.,_ ·~ ~t~ ~ ~ f'v~ j,,<pVl~. ·n+1-r-.qc:. --c: o I.A.. J ~ (1-~~l~<> • cc: a 0 6363 GRWJWICH DAWE SUITl:250 SAIJ DIEGO. CA 92122 ,51()!623-1300 0 C dOISF z "3:DVd oz: 0 N NOI.LVOINnwwoo J HM lt:;, '~b lb: !:>l oHl-1:.. I 'y l:i I UM-l\:.C., .!.NL;, 41&1 b::J.f:)':;}00 1,· / I ' -.. ( '·· /,.,_ ,: .. : ·( .. . . t.._ ' / . .. I I. «, ·" . ... • ... • -..• ,\.,,,..,·---........ , .. · ,· ····,......_,,_..: -..... " ' ··-........,-, . . --'v ~ i t I ,l i . ... ·-···--·---~!-----= SO' ii (G3:M.) 96, SO "EdV . . ... ,,. . -· ,, :·--1 } I ?:f' a .. .., : _____ Li IA ~ ... r ti !i I-' • .:l•' .:$ ... I ... . :t .,... • "!:. ~. ;;: ., . ~~ .. I u ____ _.._ _________________ -,-. ______ _, ~ C ----~.,-:-,·~ "' , .. '=--...... · .. • .. i' •• ~.;; .... ". ____ .,~\___.~,.,,'\____ , _ .... \_ .\ "· .,',_ .\... J • :-....... ),. .I . 409 f:.iS'/ 7405 P.03 I , ' \. \. ~ ....... ,- ( f l' \. ' /' { ·, ( ~ t ''-.. __ / /· I l \, ........ _ 1-.,:· ,,~ / l { / I OZ '0 N NO I.LV::l INilWJ/1!O::l 90: t t (G3M) 96 , SO 'BdV .. '1,;~+,.. .-~··r.... -.. ··-~ ..... ~-~ 'y-·--._,,,., •..• ·' ' ..,..,.__,.::o~ ___ ...J.._ ___ .,.; .. =_, ___ ..J.-_....,. ____ .. ____ ..__ __ ___,r,;--,-:~.n j_ . . . . .... -. . ~ -. . . .. I;! i .. .. i!: a .. . ~. a :l i 6 w a i i ; .. t..l. :~ I s i I i ... .. .. -·----:1-------f -.. -.--· -'\_ ..... /\ ... ,.-."-..:_,~;.,..A .. -"., .. ·\ .......... -· ~~ . ii I ~-I~ • l ~ k~ flP.• ·· I I j -.. ·:· . -H .., ... .. "" ' )-: ' -.. r~ ) '':, r .i ·1 /I f .. I .. , .f .......... , ... '\ :1 ; ./ ~/ ~\" ... -.~,t~ 1 «:;,r-· ,' <...,, ... ,J " I ' ,,,.··· __ .,,,,..,• ··,-,.... '•,,,.__ ;~-J .. , .. /<, - ·, : -. ·-~-) ; /' ,.-,•"' ~ ., . ..r' .. ' ' -:~ . ~--.. .£ •. ·' •• J'AH-1&-1996 17:54 408 637 7405 '· l ,' f _. / \, \ ( \ ./;' ( ' ' / ( \ ' l I \ I ·' ~\. / ' i \ \ \. ~~ '~., \ I ' \ \ .. ....... ~- 01': 'ON NO I.LY:) INnwwo::, 90: ii (CT~M) 96 , SO 'HdV 10:18 SAFETY STORAGE, INC. ~ 1 619 929 0528 N0.841 f;l02 .,, ------------------~·· .,,_ ...... \,· '/IN s;i~ oatm."OK (lrn!F.• 1.1ur. 1J1NG11 C111.'!') f ($.OC) r m'IION A-A SC:Al.£:1/10 r I/~-)C 2() X 3/4" LG HflC 11,AD M.lltW F'AN HOUSING A!.;~~MHl.Y Sfllrl ntm l)ING:'i t)NLY .. -··, I I I .l 1111.UO I . • m:T!Q~ A-A £t:AU: 1/IU ···-.... , 1/4' X ?.O IC :i/4" IC: Hlr.ll HV>l1 lll.:IU.W i:AN HDUSINC. ASSl.:MEII.Y FS BUILDINGS ONI Y 1/4" )( 20 X :,/'° LC HtxlltAO~ !: 1111afi•11t I Hlllllli *.JI ,. .),!Ill lll'l'Wll, ~'(. {, -·~-H:.;,:---.:-::.:···4,.;..· ·;..:i;;:r:J'·-,.---7-t---""-~-~,. CAA'TINO ~ CIA }=:z::i:.:::c:iCZ:1:;:l:'.:li:::Z:s:=lj:cem~~-'.T':r.'JP,(~_...i----f hnatt-.. B ! ll.ll'4 ·->/ l• 6.00 llllOII WAH mtKIII e-s :ICAl,U t •/2" • ,._O" INlf-N!OR VII-W .,..·· ,· ,. / t' \ ,/ ,· / .. ;-.: .... ",-~·-_ ... -.... \, _____ :··__,......._·ll--1 r~·:··_---;--'\JC/'-' 1111 -; ,i ·' 10:19 ( \ l ,. ' \ \ :_: \ } , .. · ·.· t '-.J l • ............ _, _ _.,.,,.· Ol 'ON NOiiVOINnwwoo 90: ii (CI3:M) 96 , SO <:IdV SAFETY STORAGE, INC. ~ 1 619 929 0528 12 GA A.OOR KO'tS• ·l·I VIEW B-8 Sr;\11.£: 1/10 -r 15.I~ SO I AIR !NI.ET VENi DEiAlL F"ROM INSIDE THE FS BUl!..Dl~GS 11.60 !:::;!::====:::f-_..._L VltwB-8 ~I/IQ AlR INLET V(l\;7' OETAI!. F'ROM !NSIOE THE STEEL SU!l.:>INGS '· ~~ UST£D C'..ASS 1, GIIOUP D, llmiD't !, TOfAIJ.Y £1,iCUJSEO EJG>l(ISK)ft• PROOF MOTOR WilH ~'STATIC CAST AI.UMINUlol ,.N ~-120 V, Sflcu: p~ ;?. CUCrn«l Clm!ilRUCTEt.l o• 12 GiUGt S!ttl., £XP0¥Y 'c:OA1IO NS!PE MD OUT 1/llrli INTERIOR [XHMlSI V£t.'IS. iljR IS i:XHAUSlEP Af A l!Al<IM\1111 ~ 12" rRCW FLOOR SURFAC(. ~ ···~-.J ',· ·, ,, &AIR 1111.tT V!NT$ l'OR FIR£ R.\~ IJJ,LCiNG'S WI~~ i,A\I? :.~ HOUR "lilt o.wrt:ll (12(1' ruSl&~ UHK). EXHAUST FAN DETAILS ..t N0.841 ! ' ! I [;103 ! ......... ) \ ' ; /. .. . . ·---~·,r \ l. ,: ,,/ l i. I• : c·· .. • i( '· .. ,: ;·";/ I \ \ ' '-·~· . l ; ., t '~ . ·I l· . ~ "'---\ . ·-. f ';_ •'\ ... ,~~ r 9 ·:;rDVd Oi ·oN NOILVOINDWWOO LO: ii (G:3:M) 96 , SO ·B:dV . . ..-. ,,. •..... -··- ·\-·· ./\ I /f\ Pl. 02 J..__"if{"•w>\ ··1 J' ··:, _, ... , .. , ... -··· ..... . . j • IIODa.SL&USL TINA• ifREo..,.,_. Varm:AtbDHoltaollw. •, ' ) n,,c,u. v.&ft'l'JCi&L DAMPD -.:~ ' 1i,,· ,...., __ ~ ! I SU..Moou .il-Gd'l,IIWI,..,_ aa •• I il l.L :f TIWlca.t.. "°"arffll&. 0-"lt IIQOS.tlfA,,Sl.,-G ....... s .. C......Spnfto , NORIIO.,..M. arn Ulffl"A~ ua-.swn Slm: _.. ., r t-:oa,u.." \G2imtft) Ml 11<::um SI.er. lttf' • lt1' (~D~,, 101FlfDffi) I ~@= I!;._®~~ • ' 41) Eloeuo!ml!!5fflal liMa. " OUtat ti,mMe httM 't3$•C. 212-F. a8'P • ~ !Dlfft ,uea tclt ~ •••bal~f'Ciftf) ,,.CIII.W . ~,... i 0 Mic.tG,~.,,. raq dlateff -,,.a,-sa.J. c:anm:it· : '\ / '>. ,) I \ ~ I '\ i • ~I Jat,119: ,.,_ hr, f'JTI 3 ht. • l10M!Ofhel tat1n,: i1t flt. 0 /SIS< ~ll'"""""'ffa~~~ ·~1111Mf,..._"R.,ta111AIEl91iRll•FlllllllS ....... II' __ •IILSO+m.fi a Y'f111it;Ollf/lOC r;.......,.. ,..,.. fllQ~ Dllt. : :'MAIJll!:A~ ·-....... < .. -'1 pm . ?Ca llailllllc1-lMID a 1-..,.; =--)-.._._:,.-· -'. : ' f l ••• , .... • ·-,._. ____ . ---.\ . . ',. •. -. _.·· ..... , ,· I .... " ' e."!11 .-,T ~'[-Ji\'[-i"lru PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ? E 13 68 oATe___,;../i_a_-___ V_,;-~_;./_.,-___ _ ADDRESS z 2 8 2..-,::::: 1-!Ur--D)1=r 1-t1 --~ RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR ( < $10,000.00) PLANNER. !Lif )t/ L / ZA CAMINO REA VILLAGE FAIRE COMPLETE OFFICE BUILDING ENGINEER_/_/; ---~-k _____ DATE 1:}j( C:\ WP51 \FILES\BLDG.FRM Rev 11 /15/90 City of Carlsbad 95212 Fire Department • Bureau of Prevention Plan Revi.ew: Requirements Category: Building Plan Check Date of Report: Tuesday, December 5, 1995 Reviewed by: (!__ c lxvecJ_,,- Contact Name Doug Silveira Address 2282 Faraday Av City, State Carlsbad CA 92008 Bldg. Dept. No. 95-1368 Planning No. Job Name ISIS Pharmaceuticals Job Address _2_2-'-82_F_a_ra_d..;;.;ay..__ ____________ _ Ste. or Bldg. No. ____ _ 181 Approved -The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. D Disapproved -Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. For Fire Department Use Only Review 1st'----2nd. __ _ 3rd. __ _ Other Agency ID CFD Job# __ 95_2_1_2 __ File# ___ _ 2560 Orion Way • Carlsbad, California 92008 • (619) 931-2121 STRUCTURAL CALCULATIONS ISIS PHARMACEUTICALS Pilot Plant Upgrade Storage Building Anchorage Prepared for: Ehrlich Rominger 6363 Greenwich Drive, Suite 260 San Diego, CA 92122 Prepared by: HOPE ENGINEERING 6363 Greenwich Drive, Suite 210 San Diego, CA 92122 619/457-4358 December 7, 1995 Project #95051 , --1 -·--------·---·-· _,, •• -· _., .... ,-~· I SHEET NO. __ _ OF ____ _ JOB TITLE _ ____!_,;,/ S::...:,t_:..5 ______ JOB NO. ____ _ ENGR. ___ C--_lf ______ DATE _ HOPE ~~GINE'=:._R~G-_________ CHECKED BY ________ DATE Structural Engineers ;4-AJe-11-tJtt.tt~a r=-oe I Fs. 1 se::~1 es 4 do& ;,gr <;;ri-r@·Y 6 W/iri-"C!:iB"' ~ 1/JC, ,Z e-FElJt,§ / ~??t-if clv'rL//f-~ C 11-t. c.. v ~ /J-97 cJ/J.5. I$ 'f' 514-Pe:r-'r -~ro/Z..A-~e /NC... - PA 71:!10 .5epT 8/ 1'1'96 Perz. ,P 14t;..i:F $ o .f' z_ '3 ~ tc-c:~t~ 'P µ; v 11:?2" 71£i-1Ye>wtJ A-F e,,1-Ccl ec,.,e,'l)an_ (4 7Z) "T/1-t-) T -= o,. -S-S-1"' V ..: 2.09#- Et-P& HPJS 4 1 7€~1.:;,,, <.,U ,0.5 & /JPl-12-T e:::, r 77le-F/2.,,4-,PM§ ./ ~Cl.)&-,8e=--;J?~S f? I~ Gf""C. Tl.. y C>/V ( e:-;} Co"' C .:::w-c, S .t.A-d-~AI, &4~, pea Sl-lee7 I a./ .2 c>I' Rt bric &,t 77/r:S Or2.w6 s -,t1) c-~ te;, AJ .s Fot2-ces ,;t!..e-e;;,I b A-l<c ~ -,-•. rso (_ tu. t.. rv ~ "Z· s"' eei t-'-- use tallow = ~,o Sit !/«.,tt1e1J =-4, 4t'/.. ) 15 ot... r _zr w/gttc. I P.rPez., """ s, 711-1,J Lf::':!s s r~ . ) S"w1~eD= 4314"1 ll'..gD fCP-Z.1 -f'.:\., ~ sa::iops~ •75/40 ~ r 2.¼A+ = ,25 -r-,i& "= ,Ji <(<O ~ 1u1m• •••• •••• •••• • • : q HOPE ENGINEERING Structural Engineers J 0383 Gr-,wlch Drlw Sult. 210 Son Diego, Co 92122 (0111) 457-"'"8 TIL (1118) 457-7042 Fax = 6LD5'.6'1"' SAFETY' 5TORA5'E INC. MODEL 9:2F5, D~. #5T9:2F51O S/4" HILT! KHIK SOLT-II, STAINLESS STI=EL, SPEC. INSPECTION REGUIREI?, IC.SO #46:21. (T"l"'P. AT 4 CORNERS OF eu:,cs,.) ".i • •• . . ., (E) ~INFORCED 6 11 CONC. SL.AS ON c&~E PROJECT NAME: ISIS PILOT PLAN UPGRADE \ \ DRAWING NAME: DRAWING NUMBER ANCHORAGE DETAIL REFERENCE: DATE: PROJECT NUMBER: S1 12-7-95 95051 \ \ \ \ \ ' ' \ \ , ~· r-----------------------------i @SAFETY STORAGE INC. 2301 Bert Drive Hollister, California 95023 Phone: (408) 637-5955 Fax: (408) 637-7405 Structural Calculations Model 32FS for ISIS PHARMACEUTICALS 2280 FARADAY AVENUE CARLSBAD, CA 92008 September 8, 1995 ® sAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 _ Phone: (408) 637-5955 Fax: (408) 637-7405 Project MODEL 32FS Sheet --=-2 ____ of 23 Prepared By HN Date 06/21/95 Checked By s;D Date c,/u/'l.r DESIGN BASIS -MODEL 32FS This document has been prepared under the direct supervision of a professional engineer registered in the ·state of California in accordance with commonly accepted structural engineering practices. Loads applied to the subject building are in accordance with the 1991 Edition of the Uniform Building Code. The "FS" series building designates an all fire shield building and is lined with three layers of Type X Gypsum Board. The most critical structural members used in this building are included in the design calculations. Where multiple number of similar members are used such as roof purlins or walls stiffeners, the worst case members that governs the design is checked. When explosion vent panels are included in the unit, the structure is designed to resist an internal pressure of 100 psf without rupturing or tearing. It is not designed to contain the internal pressure without deformations. ® sAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 Phone: (408) 637-5955 · Fax: (408) 637-7405 Project _____ M-O __ D ___ E=L ..... 32=F __ S ___ _ Sheet ---=-3 _____ of_-=23'---_ Prepared By HN Date 06/21/95 Checked By 5)5 Date "/l.1/'lf INDEX DESCRIPTION Design Loads, Load Combinations, Materials Dimension Overview Tare Weight Wind Load, Seismic Load Overturning Roof Diaphragm Side Shear Wall Roof Plate, Roof Purlin Door Lintel Wall Plate Wall Stiffener Floor Support Floor plate -Sump floor Explosion Pressure Explosion Pressure -Roof Plate & Purlin Explosion Pressure -Door Lintel Explosion Pressure -Wall Plate Explosion Pressure -Wall Stiffener Appendix "A" (Section Properties) SHEET NO. 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22-23 ® SAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 Phone: (408) 637-5955 Fa~: (408) 637-7405 Project MODEL 32FS Sheet __ 4.,___ ___ of _ _,2=3'--- Prepared By HN Date 06/21/95 Checked By 91J Date ~fe,/1/f DESIGN CODE: UNIFORM BUILDING CODE, 1991 EDITION Design Loads: 20 psf 40 psf Roof Live Roof Snow Floor Live FloorUve 250 psf (Fiberglass Grating) 500 psf _ (Steel Grating) Wind Seismic Explosion 110 mph, Exposure "C" Zone4 Load Abbreviations DL = Dead Load LL = Live Load SL = Snow Load WL = Wind Load EQ = Seismic Load Load Combinations: 100 psf 1. DL + LL (Floor)+ LL (Roof) or SL (Roof) 2. DL + LL (Floor) + WL or EQ 3. DL + LL (Floor) + WL + SL/2 4. DL + LL (Floor) + SL + WL/2 5. DL + LL (Floor) + SL + EQ Materials: Cold Formed Steel Hot Rolled Steel Tube Steel ASTM A-569 ASTM A-36 ASTM A-500 "8" 1" Steel Grating or 1" Fiber Glass Grating Type "X" Rated Gypsum Wall Board Fy= 38.0 ksi Fy= 36.0 ksi Fy =-46.0 ksi ® sAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 _ Phone: (408) 637-5955 Fax: (408) 637-7405 Project MODEL 32FS Sheet _ ___,;:;,s ____ of 23 Prepared By HN Date 06/21/95 Checked By 91J Date (p/z,1/qf' DIMENSION OVERVIEW I 33.13' (OUTSIDE LENGTH} I ,i------32.00' (INSIDE LENGTH}------;, r""'---1 I I I I I I I I I I I I I I I I I I -----------------------------~ I I I I I I I I I I I I I I I I I I I -----------------------------~ PLAN VIEW ELEVATION I I I I I I I I I I I I I -----------J I ~ 10.00' {INSIDE 1f!DTH) ~ I ~11.15' (OUTSIDE WIDTH)-! SIDE ELEVATION I 8.66' (HE[GIIT} I ® SAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 Phone: (408) 637-5955 Fax: (408) 637-7405 TARE WEIGHT-DEAD LOAD Roof 12 GA. Plate (Top) Roof Purlins @ 24" o.c. 2-1/4" Gyp. Board (1"+2*5/8'') 24 GA Plate (Bottom) Misc. Total Floor Steel Grating Grating Support 12 GA Floor Plate C4x5.4 Support Channel Misc. Total Walls 12 GA Plate (Outside) Wall Stiffener 2-1/4" Gypsum Board Wall Stud 24 GA Plate (Inside) Misc. 4.3 psf 2.8 psf 9.0 psf 1.0 psf 3.9 psf 21.0 p·sf~ 5.2 psf 2.6 psf 4.3 psf 2.7 psf 2.0 psf 16.8 psf 4.3 psf 2.3 psf 9.0 psf 0.8 psf 1.0 psf 2.0 psf -----------Total 19.4 psf Project ____ .....:.:.:M.::::;O~D.::::.EL~32:::.!.F...!::S::.,__ __ Sheet __ .;..6 ____ of _--=2---3 __ Prepared By n HN Date 06/21/95 Checked By '7' D Date b/z,1 ht" ~ I Roof Area = 33.13' x 11.15' = 369.40 sq ft DL = 21.00 psf x 369.40 sq ft= 7757.40 lb Floor Area = 33.13' x 11.15' = 369.40 sq ft DL = 16.80 psfx 369.40 sq ft= 6205.91 lb Side Wall Area = 2x(11.15'x8.66')=193.12sqft .DL = 19.4psfx193.12sqft=3746.531b Front & Rear Wall Area = 2 x (33.13' x 8.66') = 573.81 sq ft DL · = 19.4 psfx 573.81 sq ft= 11,132.00 lb Total Dead Load= 7757.40 lb+ 6205.91 lb + 3746.53 lb+ 11,132.00 lb= 28.90 kips (Tare Weight) Average Tare Weight = 28.90 kips/ (33.13' x 11.15') = 78.08 psf Max Weight = 28.90 kips + 5.0 kips (Accessories) = 33.90 kips ® SAFETY STORAGE INC 2301 Bert Drive Hollister, CA 95023 _ Phone: (408) 637-5955 Fax: (408) 637-7405 WIND LOAD Ce = 1.06 qs = 31.0 psf I = 1.15 Cq = 0.8 = 0.5 = 0.7 P = Ce Cq q5 I Project MODEL 32FS Sheet __ 7 ________ of ---=2=3 __ Prepared By HN Date 06/21/95 Checked By $l) Date ij~/1.J (Table No. 23-G, Exposure C) (Table 23-F, Wind Speed 11 O mph) (Table 23-L, II. Hazardous Facilities) (Method I, Windward Wall, Inward) (Method I, Leeward Wall, Outward) (Method I, Flat Roof Outward) = 1.06 X Cq X 31.0 psf X 1.15 = 37.80 Cq P = 37.80 X 0.8 = 30.24 psf P = 37.80 X 0.5 = 1°8.90 psf Total P = 49.14 psf p = 37.80 X 0. 7 = 26.46 psf (Windward Wall, Pressure) (Leeward Wall, Suction) (Total Horizontal Wind Load) (Roof Uplift) Wind Horizontal Load V = 49.14 psf x 33.13' x 8.66' = 14.1 O kips SEISMIC LOAD Seismic Zone 4, Per Section 2334 of USC 1991 Edition C = 2.75 Z = 0.40 I = 1.25 Rw = 4.00 V = (ZIC/ Rw) x W (From Page 162) (Table 23-1, Seismic Zone 4) (Table 23-L, II. Hazardous Facilities) (Table 23-0, A.3) = (0.40 X 1.25 X 2.75 / 4.0) X W =0.34W Seismic Horizontal Load V = 0.34 x 33.90 k = 11.53 kips SEISMIC LOAD= 11.53 kips < WIND LOAD= 14.10 kips WIND LOAD GOVERNS DESIGN ® SAFETY STORAGE INC. Project MODEL 32FS Sheet ____ 8 ______ of 23 2301 Bert Drive Hollister, CA 95023 Phone: (408) 637-5955 Fax: (408) 637-7405 Prepared By g>A HN Date 06/21/95 Checked By _4l. Date "/u l~f' • OVERTURNING l l l i----11.15'---t T W1 = 49.14 psfx 33.13' = 1628 plf W 2 = 26.46 psf X 33.13' = 877 plf {Width Length) (Height Length) w H = 11.15' = 8.66' 0 8.68' P1 = 1628 plf x 8.66' = 14.1 O kips P2 = 877 plf x 11.15' = 9.78 kips (Overturning Moment) Mor = (P1 '*H/2) + (P2 '* W/2) = (14.10kip'*8.66'/2) + (9.78kip'*11.15'/2) = 115.58ft-kip (Resistance Moment) MR = (DL '*W/2) = 28.90kips'*11.15'/2 = 161.12ft-kip (Safety Factor) SF =MR/Mor= 161.12ft-kip/115.58ft-kip = 1.39 Per UBC Section 2317(a) Solve for Tension Required: (Tension Force) T Mor <= 2/3'* MR ====> Therefore, SF (Required) = 1.5 Mor = 2/3'* (MR + T'*L) 115.58 ft-k = 2/3 (161.12 ft-k + T'*11.15') = 1.10 kips For Sliding, use µ = 0.3 , Net Resistance = 0.3 ( 28.90 k -9. 78 k) = 5. 7 4 kips Wind Force= 14.10 kips > 5.74 kips Shear Force= 14.10 kips-5.74 kips = 8.36 kips PROVIDE TIE DOWN AT EACH CORNER ( 4 Total) EACH TIE DOWN SHALL BE ABLE TO TAKE T/2 = 0.55 kips TENSION FORCE AND V/4 = 8.36 k / 4 = 2.09 kips SHEAR FORCE ® SAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 _ Phone: (408) 637-5955 Fax: (408) 637-7405 DIAPHRAGM AND SHEAR WALL 33.13' i:.::i u 0:: 0 c::.. i V l en w I I WIND LOAD Project MODEL 32FS Sheet ____ 9 _____ of_-=2=3 __ Prepared By ??:"HN DDaattee 06/21/95 Checked By <LJJ. ~/z1/ff' ,-' ' 7 l V 11.15· ~ I ROOF DIAPHRAGM <> (Wind Load on Diaphragm) w = (49.14 psf * 8.66') / 2 = 212.78 plf (Roof Diaphragm Shear Force) V = (212.78 plf * 33.13') / 2 = 3.52 kips (Shear I Foot) V = (3.52 k/ 11.15') = 316.12 plf (Shear Stress in 12 GA) fv = (316.12 plf) / (0.1046" * 12") = 251.85 psi (Allowable Shear Stress) Fv = (0.4 Fy) = (0.4 * 38 ks0 = 15.2 ksi SHEAR STRESS, fv = 0.252 ksi < ALLOWABLE SHEAR STRESS, Fv = 15.2 ksi WELDS SHALL BE ABLE TO TAKE v = 0.316 kip/ft SHEAR FORCE 1/8" FILLET WELD FOR 2" IN LENGTH @ 12" 0.C AROUNDTHE DIAPHRAGM ® sAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 Phone: (408) 637-5955 Fax: (408) 637-7405 DIAPHRAGM AND SHEAR WALL Project MODEL 32FS Sheet 1 o of 23 Prepared By ??!' HN Date 06/21/95 Checked By -~---------Date k/1,~/'lf 11.15' V - . V SHEAR FORCE SIDE SHEAR WALL (Wind Load on Diaphragm) w = (49.14 psf * 33.13' (Length))/ 2 = 814.00 plf (Side Wall Diaphragm Shear F) V = (814.00 plf * 8.66' (Height)) / 2 = 3.52 kips (Shear per Foot) V = (V / L) = 3.52 kips/ 11.15' = 316.12 plf (Shear Stress in 12 GA) fv = (316.12 plf) / 0.1046" * 12" = 251.85 psi (Allowable Shear Stress) Fv = (0.4 Fy) = 0.4 * 38 ksi = 15.20 ksi SHEAR STRESS, fv = 0.252 ksi < ALLOWABLE SHEAR, Fv = 15.20 ksi, OKAY WELDS SHALL BE ABLE TO TAKE v = o·.316 kip/ft SHEAR FORCE 1/8" FILLET WELD FOR 2" IN LENGTH@ 12" O.C AROUNDTHE DIAPHRAGM ®sAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 . Phone: ( 408) 637-5955 Fax: (408) 637-7405 ROOF PLATE Project ______ M=O=-=D=E=L-=32=F...;::S,__ __ Sheet __ 1 .... 1 ____ of_--=2=3 __ Prepared By HN Date 09/11/95 Checked By y5 Date ~/l~hr ROOF PLATE MATERIAL-12 GAGE (Dead Load) (Live Load) (Total Load) DL = 4.3 psf LL = 40.0 psf TL = 44.3 psf (Span Length) (Unbraced Length) (Uniform Load) (Bending Moment) L = 24" (Roof f:>urlins @24" o.c.) Lu = 24" -3.5" = 20.5" = 1.71' W = 44.3 psf * 1.0' = 44.3 plf Mx := 1/8* ( WL/) = 1/8 *( 44.3 plf *(1.71'}2) =16.19 ft-lb= 194.28 in-lb per 12" width (Elastic Section Modulus) Sx = 1/6 * (12" x (0.1046")2) = 0.0219 in3 (Bending Stress) (Allowable Bending) fbx = M / Sx = 194.28 in-lb/ 0.0219 in3 = 8.87 ksi Fbx = 0.75 Fy = 0.75 * 38 ksi = 28.5 ksi BENDING STRESS, fbx = 8.87 ksi < ALLOWABLE BENDING, Fbx = 28.5 ksi ROOF PURLIN ROOF PURLINS TS 3-1/2 x 3-1/2 x 1/8 @ 24" o.c. (Area= 1.65 in2, Sx = 1.76 in3) (Dead Load) (Live Load) (Total Load) DL = 21.0 psf LL = 40.0 psf TL = 61.0 psf (Span Length) (Uniform Load) (Bending Moment) (Bending Stress) (Allowable Bending) L = 10.67' (Roof Purlins @ 24' o.c.) W = 61.0 psf*2.0' = 122.0 plf Mx = 1/8*(WL2) = 1/8*(122.0plf*(10.67')2) = 1.74ft-kip fbx = M / Sx = (1.74 ft-kip* 12) / 1.76 in3 = 11.86 ksi F11x = 0.60 Fy = 0.60 * 46 ksi = 27.60 ksi BENDING STRESS, fbx = 11.86 ksi < ALLOWABLE BENDING, Fbx = 27.60 ksi ® sAFETY sroRAGE INC. 2301 Bert Drive Hollister, CA 95023 Phone: (408) 637-5955 Fax: (408) 637-7405 DOOR LINTEL (Dead Load) (Live Load) (Total Load) DL =21.0psf LL = 40.0 psf TL = 61.0 psf Lu = 5' -4" = 5.33' Project MODEL 32FS Sheet 12 of _-=2=3 __ Prepared By HN Date 06/21/95 Checked By -;,-~CJ>-. __ Date ~jz,J'lf' (Unbraced Length) (Uniform Load) (Bending Moment) W = 61.0psf*(11.15'/2) =340.08plf Mx = 1/8* (.WL}) = 1/8 * (340.08 plf * (5.33')2) = 1.21 ft-kip= 14.50 in-kip (Elastic Section Modulus) Sx = 1.69in3 (Bending Stress} (Allowable Bending} fbx = M / Sx = 14.50 in-kip / 1.69 in3 = 8.58 ksi Fbx = 0.75 Fy = 0.75 * 38 ksi = 28.50 ksi BENDING STRESS, fbx = 8.58 ksi < ALLOWABLE BENDING, Fbx = 28.50 ksi, OKAY ®sAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 Phone: (408) 637-5955 Fax: (408) 637-7405 WALL PLATE WALL PLATE MATERIAL -12 GAGE WL = 30.24 psf Project ____ ...:.;M:.:-,O:a.,:D:.=E=L_,,.3=2F....,.S'----- Sheet __ 1=3 ____ of 23 Prepared By -i!N Date 06~9,; Checked By ;;; Date G J- (Wind Load) (Span Length) L = 32. 0" (Wall Stiffener@ 2'-8" o.c.) (Unbraced Length) Lu = · 32" -5" = 27" = 2.25' (Uniform Load) W = 30.24 psf * 1.0' = 30.24 plf (12" unit width) (Bending Moment) Mx = 1/8* ( WL/) = 1/8 * ( 30.24 plf * (2.25/ = 19.14 ft-lb= 229.64 in-lb per 12" width (Elastic Section Modulus) Sx = 1/6 * (12" x (0.1046")2) = 0.0219 in3 (Bending Stress) (Allowable Bending) fbx = M / Sx = 229.64 in-lb/ 0.0219 in3 = 10.49 k~i F1:1x = 0.75 Fy = 0.75 * 38 ksi = 28.5 ksi BENDING STRESS, fbx = 10.49 ksi < ALLOWABLE BENDING, Fbx = 28.50 ksi, OKAY ® sAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 Phone: (408) 637-5955 Fax: (408) 637-7405 WALL STIFFENER (Span Length) L (Area Stiffener) A (Elastic Modules) Sx (Axial Load) p (Wind Load) WL (Uniform Load) w (Bending Moment) Mx (Axial Stress) fa (Bending Stress) fbx (Effective Length) KIJrx (Column Slenderness) Cc Since Project MODEL 32FS Sheet __ 1 __ 4 ____ of 23 Prepared By HN Date 06/21/95 Checked By 9D Date 0/41,/c:;r = 91.88" = 7.66' (Wall Stiffener@2'-8" o.c.) = 1.33 in2 = 0.80 in3 = 61.0 psf * (11.15'/2) * ( 2.67') = 908.00 lb = 30.24-psf = 30.24 psf * 2.67' = 80.74 plf = 1/8* ( WL2) = 1/8 * ( 80.74 plf * (7.66')2) = 592.20 ft-lb= 7.11 in-kip = P/A = 908.20 lb/ 1.33 in2 = 682.86 psi = M / Sx = 7.11 in-k/ 0.80 in3 = 8.89 ksi = (1.0*91.88")/0.90" = 102.10 = (21t2E / Fy)112 = {(2,t2 * 29,000 ksi) / (38 ksi)} 112 = 122.73 KIJrx = 102.10 < Cc= 122.73 (Allowable Axial) Fa = {1 -((K1Jrx)2 / 2 Cc 2)} Fy / { 5/3 + (3* KIJrx)/8 Cc -(K1Jrx)3/8 Cc 3} = 13.03 ksi (Allowable Bending) Fm = 0.75 Fy = 0.75 * 38 ksi = 28.5 ksi (Combine Bending & Axial) (fa I Fa) + (fm / Fm) = (0.68/13.03) + (8.89/28.5) = 0.36 « 1.0 COMBINE BENDING AND AXIAL STRESS = 0.36 << 1.0 , OKAY {i9!} SAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 Phone: (408) 637-5955 Fax: (408) 637-7405 FLOOR SUPPORT FLOOR SUPPORT SECTION PROPERTIES (Elastic Section Modulus) Sx = 3.77in3 (Moment_ of Inertia) (Area) Ix = 8.18in4 A = 1.94in2 LOADS (Dead Load) (Live Load) (Total Load) DL = 5.20 psf (Grating) LL = 500.00 psf TL = 505.20 psf Project ____ ..:,M.:.:.;O=D=E=L..::3=2F'--"S.__ __ Sheet 15 of_-=2=3 __ Prepared By HN Date 06/21/951 Checked By ~ Date ~/31/fJ , » • Floor support are placed at approximate 32" o.c. = 2.67' And supported by floor channels at approximate 24" o.c. (Unbraced Length) (Uniform Load) (Bending Moment) (Bending Stress) (Allowable Bending) Lu = 2.0' = 24" W = 505.20 psf * (2.67') = 1348.88 plf Mx = 1/8* ( WL/) = 1/8 * ( 1348.88 plf * (2.0')2) = 674.44 ft-lb= 8.09 in-kip fbx = M / Sx = 8.09 in-kip i 3.77 in3 = 2.15 ksi Fbx = 0.75 Fy = 0.75 * 38 ksi = 28.50 ksi BENDING STRESS, fbx = 2.15 ksi < ALLOWABLE BENDING, Fbx = 28.50 ksi, OKAY @SAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 _ Phone: (408) 637-5955 Fax: (408) 637-7405 FLOOR PLATE -SUMP FLOOR FLOOR PLATE SECTION PROPERTIES -12 GA-PER 12" WIDTH (Elastic Section Modulus) Sx = 0.0219in3 LOADS Max Depth of Sump= 7.0" = 0.58' (Live Load) LL = 0.58' x 120 pcf = 70 psf Floor plate (12 gage) is ~upported by channels at approximate 24" o.c. (Uniform Load) (Bending Moment) (Bending Stress) (Allowable Bending) W = 70.0 psf * (1.0') = 70.0 plf (12" width) Mx = 1/8* ( WL}) = 1/8 * (70.0plf * (2.0')2) = 35.0 ft-lb= 0.42 in-kip fbx = M / Sx = 0.42 in-kip/ 0.0219 in3 = 19.18 ksi Fbx = 0.75 Fy = 0.75 * 38 ksi = 28.50 ksi BENDING STRESS, fbx = 19.18 ksi < ALLOWABLE BENDING, Fbx = 28.50 ksi, OKAY ® sAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 _ Phone: (408) 637-5955 Fax: (408) 637-7405 EXPLOSION PRESSURE Project MODEL 32FS Sheet 17 of_-=2=3 __ Prepared By _-_H ...... N ______ Date 06/21/95 Checked By o/S Date '='ht l?f' ~ ~, The following calculations apply when explosion relief construction is incorporated in the design of the building (i.e., explosion vent panels are included in the unit). An explosion force of 100 psf is us~d in these calculations. Under this explosion force, the building may deform locally but will not rupture or tear allowing the release of flying material. It is possible for an actual explosion force to exceed 100 psf depending on what type of material is being stored. Explosion loads greater than 100 psf are beyond the scope of these calculations. {ijj;j SAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 Phone: (408) 637-5955 Fax: (408) 637-7405 Project ______ M __ O==D=E=L-=32=F...::S'----- Sheet ----'1=s ____ of _-=2=3 __ Prepared By n HN Date 06/21/95 Checked By ,Vil. Date ,/4~/fr ROOF PLATE -EXPLOSION PRESSURE ROOF PLATE MATERIAL-12 GAGE (Span Length) L = 24" (Roof Purlins @ 24" o.c.) (Unbraced Length) Lu = 24" -3.5" = 20.5" = 1.71' (Explosion Load) EL = 100 psf (Uniform Load) W = 100 psf * 1.0' = 100 plf (12" width) (Bending Moment) Mx = 1/8* ( WL/) ; 1/8 * (100.0 plf * (1.71'}2) = 36.55 ft-lb = 438.6 in-lb per 12" width (Elastic Section Modulus) Sx = 1/6 * (12" x (.1046")2) = 0.0219 in3 (Bending Stress) (Allowable Bending) = M / Sx = 438.6 in-lb/ 0.0219 in3 = 20.03 ksi Fbx = 38.0 ksi BENDING STRESS, fbx_ = 20.03 ksi < ALLOWABLE BENDING, Fbx = 38.0 ksi, OKAY ROOF PURLIN -EXPLOSION PRESSURE ROOF PURLINS TS 3-1/2 x 3-1/2 x 1/8 @ 24" o.c. (Area= 1.65 in2, Sx = 1.76 in3) (Explosion Load) EL = 100.0 psf (Span Length) L = 10.67' (Roof Purlins @ 24' o.c.) (Uniform Load) W = 100.0 psf * 2. O' = 200.0 plf (Bending Mot) Mx = 1/8* ( WL 2) = 1/8 * ( 200.0 plf * (10.67')2) = 2.85 ft-kip (Bending Stress) (Allowable Bending) fbx = M / Sx = (2.85 ft-kip* 12) / 1.76 in3 = 19.41 ksi Fbx = 46.0 ksi BENDING STRESS, fbx = 19.41 ksi < ALLOWABLE BENDING, Fbx = 46.0 ksi, OKAY @SAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 Phone: (408) 637-5955 Fax: (408) 637-7405 Project MODEL 32FS Sheet 19 of _.....,2=3'---_ Prepared By 7? HN Date 06/21/95 Checked By _,...:;..~-=---Date ~~/'1?J DOOR LINTEL EXPLOSION PRESSURE (Explosion Load) EL = 100.0 psf (Unbraced Length) Lu = 5'-4" = 5.33' (UniformLoad) W = 100.0psf*(11.15'/2) =557.S0plf (Bending Moment) Mx = 1/8* ( WL/) = 1/8 * (557.50 plf * (5.33')2) = 1.98 ft-kip= 23. 76 in-kip (Elastic Section Modulus) Sx = 1.69in3 (Bending Stress) (Allowable Bending) ft,x = M / Sx = 23.76 in:.tb / 1.69 in3 = 14.06 ksi Fbx = 38 ksi BENDING STRESS, fbx = 14.06 ksi < ALLOWABLE BENDING, Fbx = 38.0 ksi, OKAY ® SAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 Phone: (408) 637-5955 Fax: (408) 637-7405 Project MODEL 32FS Sheet 20 of 23 ----=----Prepared By a_ HN Date 06/21/95 Checked By __.__~-=--__ Date '1/e?!)?-., ··i--· WALL PLATE -EXPLOSION PRESSURE WALL PLATE MATERIAL -12 GAGE (Explosion Load) (Span Length) (Unbraced Length) (Uniform Load) (Bending Moment) EL = 100.0 psf L = 32. O" (Wall Stiffener@ 2'-8" o.c.) Lu = 32" -5" = 27" = 2.25' W = 100 psf * 1.0' = 100.0 plf (12" width) Mx = 1/8*(WL/)= 1/8 *(.100 plf *(2.25')2 = 63.28 ft-lb= 759.38 in-lb per 12" width (Elastic Section Modules) Sx -1/6 * (12" X (0.1046")2) = 0.0219 in3 (Bending Stress) (Allowable Bending) f11x = Mx/ Sx = 759.38 in-lb./ 0.0219 in3 = 34.67 ksi F11x = 38 ksi (Assume under this explosion force, the members will reach theirs maximum yield strength) BENDING STRESS, fbx = 34.67 ksi < ALLOWABLE BENDING, Fbx = 38.0 ksi, OKAY ® sAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 Phone: (408) 637-5955 Fax: (408) 637-7405 Project ____ ...... M=O=D=E=-L =32 ___ F..:;.S __ _ Sheet 21 of 23 ---------Prepared By HN Date 06/21/95 Checked By 9/\ Date C:;/4~/?r WALL STIFFENER -EXPLOSION PRESSURE (Span Length) L = 91.88" = 7.66' (Wall Stiffener@ 2'-8" o.c.) (Area Stiffener) A = 1.33 in2 (Elastic Modules) Sx = 1.18 in3 (Explosion toad) EL = 100.0 psf (Uniform Load) w = 100.0 psf * 2.67' = 267.0 plf (Bending Moment) Mx = 1/8* ( WL 2) = 1/8 * ( 267.0 plf * (7.66'}2) = 1958 ft-lb= 23.5 in-kip (Bending Stress) fbi( = M/Sx = 23.5in-k/ 1.18in3 = 19.92ksi (Allowable Bending) F1ix = 38 ksi BENDING STRESS, fbx = 19.92 ksi < ALLOWABLE BENDING, Fbx = 38 ksi ®sAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 _ Phone: (408) 637-5955 Fax: (408) 637-740~ Project MODEL 32FS Sheet 22 of _-=2=3 __ Prepared By /J\ HN Date 06/21/95 Checked By -~---__ Date ~/4?}ir APPENDIX "A" -SECTION PROPERTIES ROOF PURLIN J_ y 3.50 fix 1• ~t=18 ~3.5:~ (Center Gravity} Xc.G. Yc.G. (Steel Area) A (Moment Inertia) Ix ly (Elastic Modulus} Sx Sv WALL STIFFENER 1.18" t=12GA-......._ \to j "? . en II 0 --I · 3.86" (Center Gravity} Xc.G. Yc.G. Yc.G. (Steel Area} A (Moment Inertia) Ix ly ·(Radius of Gyration) rx ry (Elastic Modulus) Sx Sx Sy = 1.75" = 1.75" = 1.65in2 = 3.09 in2 = 3.09 in2 = 3.09 in2 / 1.75 in = 1.76 in2 = 3.09 in2 / 1.75 in = 1.76 in2 . 5.04" 2.68" 1.18" y \ £&:. X -\ . I I 1.34• I 1.34• I . . . . = 3.86" = 1.34" (Top) = 0.91" ~Bottom) = 1.33 in = 1.07 in4 = 5.92 in4 1£ " -- = (Ix/ A) 112 = (1.07 in4 / 1.33 in2) = 0.90 in = (ly / A) 112 = (5.92 in4 / 1.33 in2) = 2.11 in = 1.07 in4 / 1.34 in = 0.80 in3 (Top) = 1.07 in4 / 0.91 in = 1.18 in3 (Bottom) = 5.92 in4 / 3.86 in = 1.53 in3 ® sAFETY STORAGE INC. 2301 Bert Drive Hollister, CA 95023 Phone: (408) 637-5955 Fax: (408) 637-7405 Project ______ M ___ o __ o_.· E=L-=32=-F-s ____ _ Sheet 23 of 23 --=--Prepared By n HN Date 06/21/95 Checked By _,,, ..... ~--=----Date ~/~HJ APPENDIX "A" -SECTION PROPERTIES DOOR LINTEL 0.75" I ! l I - (Material Thickness) t (Center Gravity) Xc.G. Yc.G. (Steel Area) A (Moment Inertia) Ix ly (Elastic Modulus) Sx Sy FLOOR SUPPORT 1.71' 1.63" y I lo ~ --+G X -,-'b, 0 ...i= 7-'") c-.i = 10 GAGE= 0.1345" = 0.85 in, 0.92 in = 2.13 in2 1.96 in = 1.59 in = 3.31 in4 = 0.84 in4 = 3.31 in4 / 1.96 in = 1.69 in3 = 0.84 in4 / 0.85 in = 1.00 in3 i----s.O"- Y ,.._ -..,. 1 --i--11--1;--X C.G. 5.7~ -~ t=12GA l ---o.60"-j f- (Center Gravity) (Steel Area) (Moment Inertia) (Elastic Modulus) Xc.G. Yc.G. A Ix ly Sx(Top) Sx {Bot) Sy I = 3.59" = 3.58" = 1.94 in2 = 8.18in4 = 13.52 in4 = 8.18in4 /2.17in = 3.77in3 = 8.18 in4 / 3.58 in = 2.28 in3 = 13.52 in4 / 3.59 in = 3.TT in3 ~~lb-~~ l~-~~ ~F£TY STORAGE, INC. aee 6375955 " . -. ~ factory Mutual. Research 11st Boston.Providence Turnollce P.O. Box 9102 Norwood, Massachusetts 02062 3V1A4.AF' (6049) I INTRODUCTION rLAMMASLE ANO COHSUSiiaLE LIQUID · STORAGE BUILDINGS· : troia SAFETY STORAGE, INC. 2301 BERT DRIVE : HOLLISiE~. CA 95023 August 12, 1992 1.1 Safety storage, Inc. reQuested Approva1 of add1tiona1 models er their storage bui1dings. These building$ are des1gne~ to pro~ide a safe, secure statage area. with secondary containment, tor chemicals, hazardous waste materials. an_tl flammable or combust1~1e Hqu1ds. · ; ·. l.2 These building$ w111 be 1isted·in·the tlammab1~ Liquid Equipment_ Section of the factory Mutual Research C0rp0rat1on (FMRC) Approval Guide under t~e heading. Storage Bu11d1ngs for f'lamniable an~ combustible liquids, as follows: · WITHOUT ,EXPLOSION R~LIEr Models 4FS, 6FS, 7FS, lOrR, lO~S, l5FSj 22rs, 24,· 24FS, ~2, 32FS WITH.EXPLOSION RELIEF Hode1s 7FS/EP, 10F~/EP,' lSFS/EP, 22FS/EP, 24EP. 2~F'S/£P,.32EP·, 32F'S/EP 1.3 These buil01ngs were evaluated 'in aceo·rdanee With the requirements of' FMRC C1ass 6049, standard tar Flammable and Co~bust1ble Liquid storage eu1.101ngs. dated August 19'1._ : . · · · : . · ' •', 2'd o 80:01 S6~ 90 AON i I . I I i ' i I I i I I l : t ..... RC\" BY: \ 1-4-UG: H:03AM: 1 019 H29 052B-> ------1u -· I _,_,.,.,_, ., ....... ~loJ """"""'IJ~ (:j~:3:1755:# 7 1-·.;i...-1 - .·: SAFETY «JBJ 6El I .SSS6 FAX: 408/637/74lJ:5 Mr. Doug Silvera tSIS Pharmaceuticals, Jnc.. 28D Faraday Avenue Cadsbad, CA 92008 PH: (619)-431-2389 FX:(619)-:929-0528 January 3, 19S5 Re: ~eri0r Wall 0e&ig~ of Madel 32FS for (SIS Pharmaceuticals. Inc. Dear Mr. Silvera: The exterior walls of the Model 32FS are Type 11N construction and incorporate Under .. writers lab~tarie5 (UL) Fire Resistance Rating Design Number U505. The U505 Design is used in conjunction with tha load-bearing structural steel design utII~ in 1he Madel 32FS to create a Factory MutuaJ System (FM) Approved two-hour (2 hr.) fire-rated exterior wall design. The fire rated walls and ceiling of the .. FS" model, consist of 1'" thick UL Classified Type sex fire-reslsti.ie gypsum wallboard aandwiched between two (2) layers of 51s• 1hiek UL Classifled Type SLX fire-resistive gypsum waUboard using a famlnating com- pound. Each layer, in tum, is fastened tQ 14 gauge steel studs. The inner StJrfaces are proteded by light gauge epoxy-coated galvanaaled steel sheating. This provides a fire-rating for internal exposure. The outer portion cf the walls is a uniti%ad swcture consisting of welded and corrosion protected· heavy gauge sheet and strudural steel creating a weatherprc0f barrier. · Sincerely, SAFETY STORAGE, INC. ~?7A-r- Jaffrey J. Dunagan, P.e. Director of Engineering ,. . .. --~ l I I• .I " i ··U • . ~ .J RC\ BY: I I DE:PA~f,..EHT OF" 1-9-96: 9:24A~ : CCJTT ECM-. CrTY OF Los ANGELES CALIF-"OHNIA E:·i232755: # 5 WARREN V, O'BRIE~ (lt:NEl'IAL MAl"f-'"R . BUILDING lt.ND SAF"tn"Y 401!, ci-r'I' "4AI.L . LO$ ANC.EL£S] CA 90012 .. 869 TIMOTMY 'TAYLOR EXECUTlvC OF'f'ICER ~ .... 1· _;f, -· ,-... ..... ) I I ! ! . I l Saf~ty Storage, Inc. 23dl Bert Drive I Ho,Iister, CA 95023 I Ant Kenneth Wilkins (40~) 637~5955 I ; I I . RESEARCH REPORT: RR 25189 Expir<!S'. May 1. 1995 GE~RAL APPROVAL -Safety Storage Buildings' W111crproof Panels. l I l DErAILS SafCrtY Storage, Inc. weath~rproof panels are welded 10 gage thick sheet steel used in prefiabric.ued storage containers. l . . . I The! approvnl is i:uhject to the following C<mdir icm(s): i . . l. I The fabricmion of the: weatherproof paneLli .sJmJI bl.! done in rhu .shop of a licensed Type ! · l Fabricator approved: by the City of Los Angeles BuiWing D!.!f1t1rtment. i ' I DISFUSSION I , l j ' 4 The/approval is based on water penetration tests in accordance wirh /\STM E514·90 modified to }jsTM E33 l ·86. ' I This! general approval of an equivalent alternate to the Code .is only valid where an engineer andlbr inspector of this Depa"ment has detemiined that all conditions of th'is approval have been met lin the project in which it fs to be used, · l I t RJ{ 25189 \ AN f:OUA" l!MPLo-4,eNT OPPORTUNITY_ AFFIRM P.~1.:c· I ol 2 : .q TIVE ACTION EMP1.011-~a RCV BY: 1 -!:J-96 B: 25A~1 CCITT EC\1-> G:2:3:27fi5 : # fj " . .. ,. ..... ! __ , l Sa.f~y Storage, Inc. · RE: i Safety Storage Buildiqgs' Weaterproof Panels I ! Add~essee to whom this Res~arch Report is is!'.ued is responsible fol' providing copies of it, complete with .iny auachme~ts indicutc(J, to architects, engineers •tnu builders using items a.pprpvcd herein in design or ~onstruction which must be approved hy Dep~mmcnl of Building and Satety Engineers and Inspectors. a~~L IBRAHIM HABASH!, Chief: Re~arch antl Development division i ! . APPi.ROVED BY. I I ! I , .. !1'". ·1-----.. l lj ,.......,,.. . / . . . v· ,, ,· .. ·. t I.///.,-"' ./4 :, ,.,, .. ,.,.. , ..... ,.·· ,., ~·: K .. '.ROBERT A fERS, Chief : Resqurce Management Bureau i l ! Ml' KBT:~:J. R~51ft9 R3,2tl.•.irl 211w,1111 I i I RR .:25189 P:igc :! or 2 TOTAL P.06 . ._I ..I ~ '* I.(.) lO "'" r."l ,;,:, "' '° t ::.; ~ 1-, E- u u :; < ""' ~ Ci.I (!) 0) I Ci.I ---------------------------:---------------------i Bepnrtmettl nf 11Juili'ti11g antt ~aftty Clr..ertifitate uf .l\pprnunl FABRICATOR'S LICENSE NO. 1409 TH IS CE BT IFIE S THAT SAFETY STORAGE. INC.. LOCATED AT_ 2301 BERT DRIVE. HOLLIS~ER, CALIFORNIA 95023 1 --• ··1-s--A--P Pil·Q-V·E·iJ····B··Y···--r-H·E ·D·E-P-A··n·T ME--N·T -o F B·-u-1t·-n IN a···A-~lJ-""S"A"F'E'T y--u-·N,YE'R-----·-····----.... THE PROVISIONS ·or SECTION 96 .. 203 O_F THE LOS ANGELES M UN 1 CJ -P .A L CO DE A 5 A TXPE I FABRICATOR OF LIGHT WEIGHT STEEL ( LWS) • ·DAT.Ei March 30. 19 94 --------·A-NNtJM-RENEWAt-;-·---APR-~L--1-,------· ---·-------------·--------·------.. -· -- ;:. TfflS CERTIFICATE.IS THE PROPERTY OF l'HE CITY OF LOS ANGELES co -AND MAY BE REVOKED FOR ANY OF THE CA US.ES S£T FOflTH IN AftTJctE a, CHAPTER 9 OF LAMC. ~ .s •-24t :11n.t.1t RC\' BY: !' . I --I • -.. ~ 11 \J . J . r, ' . • i I I . --.. ~ •• . I • I ! 1-9-96; 9:23AM: CCITT ECllh .. Iii I Pt t I 18785 I ~ I . .;. . .. t .. :, ,!• •• •• ! .. 1 : .. ·,a~··· . . Da . ~ -s. .It, .. .-, al At1f!OII -• ··t.. soo !!fr, . . .. ,- ......,.. ,,.,_ ~,., .~ f•d •.... l~lcl "'~·· -~f· : ... ,.r.• •.. ~,,;.,. ........ , ·,. I ·"'ii~ -~,~,i:· I o I. 1f I . ·:.,, -~~-~, ~,-, .. -... ·· .. \ I I,.,.. : .. ,ftic,41 • : •• • • I •' • ,• • . . . . ,·,· .. . :, ( ~! I I .,,,~'t, 1 • {: t ... • • ~ ~ IJ4t" f • ~ ~11 l'fi , : .'• 11 , I, \ t • I ' ' . !I' .., . .__, _____ .__ _____ .., • .. 4-. ... ttMAM t-i!II .......... .-·,· ,.,,..,.......,.. ... ... IJIW-"•'Wllullat-·..,..,, ~ .. ~ .... --..... •-o.4'C.•eit, -... ........... \lt ... C:i..-.:iolO I .. ' . \ .. • .. .. . , I i . I I . ... I . : i i !• .. 82~32755 : # 2 ' . . . . . • • • ,,, .... ·, .. •. .... .. ·_ .• . .-• •• ' ~ . . :>• z : ~Vtc.:6: 96-6 -T I k \,._ I ? t • -.. -e ! . • -- -I I I . ' t I I ! ... : I I -1 ·-.., i : I . ' I .• , .. . . I· t Ii i • I : -JJ I , .. t-.. ' a:!! I UI j • I GI ~ I ..I l I I < ·Ii· ~ :I I i •. - . I I I --~- • --· . -a . • , ___ .. ··- I I I• I : i ' I I i I I • ). ..., ;· ... ' . .. .~- ••• •• SAFETY STORAGE INC . 2301 Sert Drive Hollister, CA 95023 408/63715955 FAX: 408/837:7405 December 14, 1995 Mr. Doug Silveira Project Manager ISIS Pharmaceuticals 2280 Faraday Ave. Carlsbad, CA 92008 Dear Mr. Silveira: Model 32FS-7018 Sales#4932 The 1991 Uniform Fire_ Co~e, Sec. 80.301 (m)2. requires the following: Mechanical ventilation shall be at a rate of not less than 1 cubic foot per minute per square foot of floor area over the storage area. The fan installed in this unit is ventilating at a rate of 450 cfm. . __ .. ,._. --.. -. ·-· -. ---- The square footage of floor area Is (120" x 383n) / 144 = 319 sq.ft. Thus1 the required ventilation rate per code for this unit is 319 cfm. The fan is venting at 450 cfm which is greater than 319 cfm. The inside volume (Lx W x H) of Model 32FS-7018 is: (383" X 120" X 92") / 1728 = 2447 CU.ft. The number of air changes per hour is as follows: ((450 cu.fl per min.)./ (2447 cu.ft. of area)) x (60 min. per hr.) = 11 building air changes per hour. Please feel free to call me with any questions. CC: Ken Ederington Diane Maler Debbie e. Cord9urs, --~c?Ll~- Jeffrey J. Dunagan, P.E. Engineering Manager .. 24/10/95 10:18 SAFETY STORAGE, INC. ~ 1 619 929 0528 @ SAFETY STORAGE INC. 2301 Bert Drive Hollister, CA. 95023 Fax Cover Sheet To: Mr. Doug Silveira Company: ISIS PHARMACEUTICALS, INC. · Phone: 619-603-2369 Fax: 619-929-0528 From: Jeffrey J. Dunagan, P.E. Company: Safety Storage, Inc. Phone: 408-638-4019 Fax: 408-637-7 405 Date: 10/24/95 Time: 10:06 AM Total Pages: 3 Comments: Hello Doug, The following is the fan housing details we discus~ed. The system will: Operate continuously Exhaust directly to the outside Provide 6 air changes per hour ( or) 1 cfm per sf floor area The system provides: Air outlets located </= 1211 from floor Air inlets located </= 12" from floor Cross ventilation Break glass fan switch Please call with any questions. Thanks,W'_t2...,.--- Jeff Dunagan N0.841 [;101 r\'2 24/10/95 10: 18 SAFETY STORAGE, INC. , 1 619 929 0528 N0.841 -------------------· .... ···-···· ... f/\N :'Jl-llJT:£1l Ci<TCNtJON (5TF.l:I 8lJJl lllNCS CNI.Y) r cs.oo> FAN HOvSlNC-·0•• SF.CTICN A-A SCALt: ;/10 I/~-X 20 ~ 3/~-L~ HFX !IFAO fiCRf.W FAN HQlJSiNG A'.;St-MHl.Y Sl"f-"H HliH DINGS ONLY GYPSUM WAI..L BOA'ltl 12 GA-... FLOOR ,._ ..... ··: • 6,00 FRO!.I WAI: SECnON 8-8 :;CAU,: l l/2" -1·-0· 5r.C:TION A-A SC:All: 1/IU rtllC O~MPCl'I _! 1;,: X ?,O X V4" IC Hl:.X HU\IJ ~c.;m,w FAN HOUSINC; ASSEMBLY FS BlJILOING'.5 ()NI Y ... , .... , ...... 1/4" X 20 X !'>/4' LC HEx IICIIO SCRCW •• -:;,"""AIR INLET VENI __ ... ---················ /' Fl.(lOR MATIN~ IN 11-RiOH Vl!-W .-J.UO Al'l'l(UX. Off ~LOUR GMnNo 2.94 1;02 I Ill I 10: 19 SAFETY STORAGE, INC. , 1 619 929 0528 12 GA FLOOR NOTES: .... ,,..--..-----r 7.,3' 9-fS VIEW B-B SCALE: 1/10 AIR INLET VENT DE,AIL FROM INSIDE THE: FS BUILDINGS 9.08 11.60 V.EW B-B SCALE: 1/10 AIR INLET VENT DETAIL FROM 'NSIDE THE STEEL BUILDINGS I I. l.,L LISTED CLASS I, GROUP D, OIVtSIO"< 1, TO,ALLY ENCLOSED EX?LOSION- PROOF MOTOR \ViTH NON-STATIC CAST ALUMINUM FAN BLADE. 120 V, SINGLE PHASE. 2, DUCTING CONSTRUCTto or 12 GAUGE STEEL, EXPO)()' COATED INSIDE AND OUT WITH INTERIOR EXHAUST VE1','TS. AIR IS oXHAUSTED AT A MAXIMUM OF 12" FRO!/ FLOOR SURFACE. & AIR INLET VENTS FOR FIRE RAr::o 8\J,LOING5 WILL '1AVE ,.s HOUR' FIRE DAMPER ( 12<7 FUSIBLE UNK). EXHAUST FAN DETAILS SAFETY STORAGE, INC 2301 BERT DR. HOWSTER. CA. 800-344-8539 N0.841 [;103 , . ·-· I Pl.oz ! i IIOD&SL.&USL TrP,eA• #fNOAAt,._ ~ANDHoRllONW. ' I~·,- t""tl!a.....,1 °'. , I • j I • \ I, SWll.tNEMcaas G;i1-. S.fill. 1n 11rll)Cldng Sllans ~-. F1,5ete uni. IR(!~l~t>ti,i J~·F~ vafflCAL StZ1t IAll'TaT10~ •• M~.$,n: _..,. it,W 1,tr211'11n • ~l -'1tMlll"IU8t Su ,!If" " ,..-. (t2111IM'II ,, 1~tSlmmt TYDlca.t. ~ltOMTal. OAMPEII' IIQOB.: NA-$1..-43 '!1tllfl!M, SttM!I eao.i.ataSpf,flV , ...... I t.lS1'!0 AND lA8E4tED s-,_ tn~® • Elmro ilftf:ffl'l:ill liMa " OU!!!r t;.isltlle hfliia l2S"c:. 2,rF. M"'F • AOf4.illitaibl9 tila!Jll $ta.al 11:Jr CIDl'llllll'ISfiOft ti,,e,ba• ~r:cmg daff!0191" • ~.1'1(1~ rlfleau I • Mi!:.roi~t~ !?r raq abut Off ..inc,10, ~• COflffO!' : ., i < · /SIS tr .. ·: ~l!i&pm]J c'.0"d I ..L ll«>Rlt01CTAL lU2-u•rrAnctQ:·· Ulftl"1Uffl Sitt: , .. ,, o.--f~021\'111't "'. tcnffl!l't} Uaai"'u'" s1,r. 40" • ,cy c~o,emr,.,, 10,Sl'arl'I, 8c'.S06c'.66191 01 J1101'1) """""''fzl!lf ~ ~Ar, * IIOl!tl!l!'t~ ,._ ,,...tt) IL w•a.1..-... fO"nQ lo.:•itO~ . .. .Al.St:Hl"'.L~al.£ IIS 'f'ft'E&O ,-0 C I I i i I ' ! ~-... -.. ·-~-......... _.,._.,., .... lllll!IOi-~ ,__._,.__-¥.s•""""._'IIIIL..., =......_~ I ~ PO. fflJmber: i i DIiie. . ritm~~ WOcl.:I 9c'.:ci: S661-0l-nON JHN lb '~b 16=!:>1 !:iHl-1:.IY !:ilUr!f-l(±., lNL:. 41.dl:! b~V:>':::;i!:>!:> 0 ... ,., II') ':nl II I "r,"' ,,..,, !i: fflj :=~=--t~::::::::c:::::=:~---··j· ----......... . -·----~-------I .. .:.· . .. ·:· Cl u ., .. JAN-16-1996 17:54 408 637 7405 • I ,. I I I "' ·{ r . f el ·. ·f l ·:i . r • l .i r I' l 1· I· . j l ] I :1 . ·f. J j l .~ I J .. i .. !, .l _:j "' . ·I ~-1 ...... . . l' P.02 JHN 16 '':;lb 16:!:)l SHl-~IY Slllk'.HC±.., ll'IC. 41dc! b::l"(:>'::;I:>!:) I-' • .:!I'd ' . ·l ~ lJ . "' J 1 ~ -I~~ ,,. ........ , ......... ~ ... 1, ~ -~ ' ~ ... i ... .... •. ;i •. 1: . . ~ • l> ~ :t i 111 0: i 51 ~ 'f . .:l )j:l ,~ ii __ ~ • ~-ti • . ·-J I •i! .. f-' i 11 . "' l. : -T J I l J kl:-I ;:;· ~ .... I . i u: : _____ :j l :f .... ; I ~ ~ I ·I .... S-1,1 § i l!i i *-7· ... ~ l ~ it ~ ~ ... t . ill i i .. J\ 31 ~ \. I . -......... r C!:. 5 &_ li __ J .t :.: J ... ,.. .. I : ··-· ·-· ··-: l "' 10 --Q i Cl .. -c . . .. JAN-16-1996 17:54 408 637 7405 P.03 . . , I I 'i;' .. RC\' BY: 3-5-96 :11:0BAM 1 :' I : . : j I I . . LOCATI~; ISIS . ~RMAC~ ~CALS ,~ 2280. :AR.ADAY VENUE CCITT ECM""' 82~2755:rr 2 SAFETY STORAGE INC. 8306 Wil&hte &xilovani • Sui:e 9000 Severty HiRs, CA 90211-23-U Tel: (213} 939-5115 • Fsx: r2n; 939-r64S C . : BAD;. ;QA rzoos . ~PECS fo ;•20H~l.1FIR.E-RATED HAZARD MATERIAL STORAGE ~IT l . · . : I RE: I : 1. sAFEfv STOR,\ i INC.;, ~ODEL #32-FS . . ' ! 2. D~NSIONS:· ; · : . I I 33 1 6Jil.e~gth x 1 'i 6". ~dth J!j 9' Height 3201 . 1uare feet I t~ri~r stora1e space. . 3. RELOtATEAB. · ~The ~i,et: is designed.around the premise that it is relocateable { when empty } . The b m has fo t-inch ~'C." dhannels for forklift access every two-feet the entire length. , • • I · The "9" _chann~s ~vi~e i:l~ni~orm load spread. J I : ' I 4. CON$1RUCTIO ~ "2 HOtJ:R! FIRE RATED'': Building WILL be "2-Hour Fire Rated" from sump up to an~ including· e ce.iling~r~f { "UL" approvecl'design }. ' I • i : : . I , ~IOR W · CONSTR.UCl10N: Two-Hour (2 Hr.) Fire-Rated Noncombustible Construction in acrord~ce w/ -<263 andiASTM-E119, with Multiple I.ayers of Type-X Gypsum Wallboard Encased betw~ Exterior· '. Gauge, (IQ GA) and Interior Eighteen (18 GA) Corrossion-Protected Steel Sheets. I : . ! ROOii/CEILING ONSTRl:;rqrION: Two-Hour (2 Hr.) Fire-Rated Noncombustible Constructionj in in accprdance wit tJL 263 andj ASTM-El 19, with Multiple Layers of Type-X Gypsum Wallboard ~:f between · : erfor 7'f' Gauge (12 GA) and Interior Eighteen (18 GA) Corrosion-Protected SU!WALL a NSTRU~l)ON: Two-Hour (2 Hr.) Fire-Rated Noncombustible Construction, in acco ance with; : 263 and ASTM-Ell9, wit Multiple Layers ofType-X Gypsum Wallboard Encased betw·1 Exterior ; d Inte~or Ten Gauge (10 GA) Corrosion-Protectec Steel Sheets. i . . : 5. ROO:f DFSIGN: !h~ roof des~gn has a minimum Three irich (3'') negative slope going from front-to- back tp dire4t wea :er :run~off ~way from the loading area. The roof will be permanently attached to the locke:t1. , · j · 6 ~ON RE mJi' co~s/rn.ucnON: The walls of the unit will be reinforced to handle up to 100 p~f. The unit ill be eq~jpped with four (4) explosion relief panels that are designed to handle from 20 ps~ up to lOOp f of explosiv~ pressure. The panels will be weatherstripped, chained ana latched on and will have inte~ior secliritjy tiars to prevent unathourized access i ! . I RC\' HY: 3-5-90 : 11: 08MI CCITT ECM----> 62:32755: # ~) SAFETY STORAGE INC. 8*'6 WHfihlrri lkNIBvard • SUit!S 9000 &i~ Hilf1, CA 90211·2344 T~: (213) 939-6715 • Fax: (213) 939-1648 I I 6. SEISMIC. HOLD- install for end-1.i 'WNS: ·.~h corner of eacr locker WILL .have a 4" sei~ic hold-down bracket Zone-• r finish into!the foundation. The hold-downs are calc'd ~d d~signed for "worst case" 7. GRO . NDIN"G: ch locker ~L include interior bonding lugs, exterior grounding assembly and an eight-oot (8') gro nding rod shipped inside for end-user installation into the foundation after delive: . · i . . ' 8. FlNIStJES: !NIB IOR Finish ·Wn..,L be primed and painted with a chemically-resistant white epoxy. EXTE~IOR Finish L be a g~ossy, heat reflective white colored aliphatic polyurethane with a µndercoat o high solids c.:poxy (7 mil thick). j : . 1 . 9. VENT~TION: he locker-WILL have natural gravity ventilation for incoming makeup air. AIR VENT' ; Two (2) ir Inlet Ven~ WILL be 11UL 11 listed "1-1/2 Hour Fire Ratttd" dampers, Dampers have a'. alvanized· ~I Frame. !Curtain-Type Galvanized Steel Blades, and a UL Listed 165 degrees Farenn~it Fusible ink. The Air Inlet Vents WILL be designed with fusible links that melt and the louverS. that close t stop air flow in the event of a fire. These vents WILL b~ engineered to provide "in comin~ make-up ai " only and should not be used for the withdrawal of fumes ( no exterior suction device~). There wi I:be one venf per room. / . . \ 10. s'lJM!P CAPAC! : 1,460 QALWN'interior spill containment i I • 11. RAIS~D.FLOO lNG: FIBER'(luss FLOORGRATING: Chemically resistant pultruded Fiberglass Floor£· rating. The . ultruded "T -.Bar" fiberglass WILL have a minimum 350 psf uniform load bearing capaci; y. Fire Re : t Isophthalic Polyester Resin fiberglass WILL be corrosion resistant and "UV" ; ltraviolet ~epellant. TI;le fiberglass floorgrating inst.allation WILL run front-to-b~ck and in appro¥mately fo -foot (4') se<.'1tions. Bowing WILL be eliminated by the uni:form load spreads design :through u~ the flooring substratum section. The Flooring WILL be.of a "35% Open-Area chann I" design fo visual ins~tion of the recessed spill flow sump. The Top-surface WILL have quartz grit/baked xy "Anti-S.kid 0 permanently bonded to the surface. 12. D00 OPENIN : The locket WILL have One (1) 36" W Door and Five(~) sets of dual-doors at least sixty nches (60") wide and eig~ty inches (80") tall. The door openings WILL exceed code req~ments with a ·"3-Hour F~re Rating" ·as approved and labeled by Underwriters Laboratory. Each door ivill be ship I with a "UL" label present. Each Door WILL meet Federal "ADA" Requirements. , I RC\' BY: a-5-9€-i :11:0BA!\l I j CCl1T ECM--> __ .......... . 82~32755 : # 4- SAFETY STORAGE INC. 83()6 Wilshire BoufBvBm • sutts 9000 ~wny Hi/JR, CA 90211-23,U Ts/: (213) 939-57'6 • F~: (213) 939-1646 : l .. Llll:aticj1n ISIS PH J:CMACJr\!TICAI.S . · · · 13. SEC~: Th: "Dual nobr• opeiting WILL be seeUied by an exterior keyed lock with a ·t-point' bolt fucking systeln. · · . I • 14. SIGlqE:.The oor opening WILL receive one (1) metalt weather resistant, "D.O.T." placard which acts · a flip-~ha . type conte* c~rifier sign. Each door· opening WlLL receive one (1) '*NFPA" 704M ~aza ! ous ratinglgn. . : : . 15. GRO~.ING: he unit will have an exterior grounding connection with a 10' grounding rod and associated cable d lugs to ground upon site placement. The interior of the unit will have four (4) interirr buss bars. i 16. FIRE SUPPRES ION SYSTEI\f DESIGN: The PRIMARY Fire Suppres~on System WILL be an "AU OMATIC" Dry Chemic.al Fire Suppression System which includes; FOUR (4) dump heads with plasti: cap covers that blow"(lff upon dry chem activation. The system will provide 3,840 cubic feet of dump upon activa ion of non•toxic material. The system will have an exterior mounted audible alarm wiredj to activate pon dry chem activation and set of dry contacts for centralized communication. The systetj1 will have ree activatitjn points one (1) automatic via fusible-links and two manual pull stations. A break lass box will :be placed over the remote pull station. A Weather-proof enclosure over the b~e holding tb.e dry che~ical and its "system brain~" per NFPA 17. The system is "UL" & "FM:'1 Approved r product arid installation method. i I 17. Water1Suppressio asser1>lecl and p ! $ystem ·tt~ack-Up Only"; The unit wHl have a 4 star h~d water sprinkler · ped and -in~talled to an exterior pipe fitting. 18. ELEdTRICAL S ST.EM:: The interior electrical components will all be explosion-proof (wiring, seals, and c~nduits). On (1) :exterior1load center WILL be located on the unit and WILL ho1d all requitbd breakers.! · · · j I • • , 19. LIGHfTJNe-JNTtR10R: FOUR (4) explosi~n.:proof interlor lights will be installed inside the locker with ~xplosio:::pr~of ( ClassI,iDi~sion_ 1, Groups~_& D) cornpo~ents an~ hard w~red to the ex~ior break~r box. Th§ncandescent ~ntenot light fixtures Vfil~ pe "UL" Listed and. "UL" Listed Installation for h&aroous 1 lions and c;:onsist of a 300-wa:tt bulb, heavy duty globe, and a sealed heavy duty alumi~um housin that has been finished with epoxy·'( CLASS I, DIVISION 1, GROUPS C&D ). The·e~terior light witch will be a "UL~-Listed and Weather-proof. · ·: ! 1 i 20. ELECTRICAL RECEPTAt~ES: T~e unit will be equippoo with Six (6) Interior 11 UL" Listed Duplex (double gaqg) Explosion~Proof Receptacles rated for Class I, Groups C&D, Divsion 1, Hazard Locations : RCv BY: 3-5-96 : ll: 09AM ~l CCJTT ECM-> 0232755:# 5 SAFETY S-TORAGE INC., B:106 WilslllM Boulevard• Sum !K100 St,~ Hi/11. CA 90211-2:M.4 Tat: (213) 939-5715 • Fax: (213) 9.3fM~ " l 21. FlJl\1' REMOV : : The Fill46 REMOVAL SYSTBMWILL be electrically Powered, explosion· Proofl(Class 1-DiE·sion 1, Gro9p D)~ forced air, mechanical and installed ptjor to shipment with all hard iiring finish . off. The Sf stem's parts and installation method will be ~UL II Listed and Approved. Each fume Remo al System wpll remove fume build-up from the interior provide approximately 56 air changes per hour xceeding Me requirements. The system WILL be designed with interior ducting to draw rumes up an out to.the e~terior for removal from within twelve-inches (0"-12") above the flooritig surface i a sweeping motion to meet the intent of the UBC/UFC c~de requirements. The si,stem will h ve an additiJnal flexible hose for localized exhaust that can be used directly over a drum~ if needed. e system ~ill be designed and installed to run with all the time. A breakglass box with ¥ overide s itch will be Flstalled on the unit w/ labeling. : . I 22. CUS~OM PIPE ENETRA110NS: The locker will be equipped. with fourteen (14) l" pipe penetj'ations with oth ends thrbaded & capped and two (2) 5" pipe penetration woth both ends threaded &ca~ped. . I . . l ! l ! 1 i i l ! i j. ! ; i J 1 1 i TOTAL P.05 , t . ri''l0/25/95 08: 52 '5'619 431 1601 CMWD +·H LAS PALM l4J 001/002 Dept. Phone# Fax# Fax# BUSINESS NAME.__.L~~=\..__:::,_,__,..___ ....... ..___ ......... ~=--'-'-_.::_...c-------------- SITE ADDRESS 22'.?>? ~IAiR.A-{)A::f i\-0£ CONTACT PERSON (at business) ~C.2wkrA:5t :$.'" v::e:! R.A PHONE NUMBER (G?!fi ) l.f 31 -~'.s~°' Type of Business (check all that apply) D Agricultural DAssembty D Automotive D Chemical Handling D Electronics DFood D Government D Laboratory D Laundry D Manufacturing 0 Medical D Metal Work D Office D Photo Lab D Retail D Service Station Dwarehouse Gkither ~~ ~ Qcs,-.1 'e H?P ~'W':?r k:!:9% DESCRIBE WASTE OTHER THAN DOMESTIC {Chemicals, Particulates, etc.) £;tJ E:•'.YM&fA>< w !':'::'$:Tc DESCRIBE BUSINESS ACTIVITY: 1? E$ e~ k\J) A).cy c<-oll?nc4hl:r ~Be,iiW\,m:A,u$5- fu \'2, 'EH,"""!o~C E, 217 CfA:h u R-LdGSa GENERAL DESCRIPTION OF ONSITE WASTEWATER PRO(?ESSING: (chemical & physical characteristics)_ Is business presently in operation at site? C91es D NO Has Wastewater Discharge Permit been applied for through the Encina Water Authority? ffiES D NO Applicant's NameDo"-'<er..A\-'=> $, ~1c__v¢1.fuA. litleDrlL Coe..e. G\'f\PL. Phone (Celct)t{~\-'2..'¼j Please Print · .,,. Date forwarded to Encina _______ ....._ __ _ P:\PCCS'UIISFOlltlS\Fll"°8045 REY. 2/10/92 Hazardous Materials Business Name H-~?~ SAN DIEGO REGIONAL l-l 2.CJ4 SI HAZARDOUS MATERIALS QUESTIONNAIRE No ~A~ l,st&i Contact Perso Telephone -~;,,.;.·-· . i " ' . ,.., 11-: II Plll1III Cll1lll llfflll' COIITY If UI DIIIO t.,.,.,AL<;,. Dc:::,00 1L..'16,~<A-(;Ct 4.'~ v--'2.'sG Mailing Address City Zip Plan File# z E.. ~~~ :,.p..r/::) CA 42c::,o Site Address City State Zip Plan File# PART I: FIRE DEPARTMENT· HAZARDOUS MATERIALS MANAGEMENT DIVISION: OCCUPANCY CLASSIFICATION Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any or the items are circled, applicant must contact the Fire ~rotection Agency with jurisdiction prior to plan submittal. ·. Explosive or 1:slasting Agents 4. F·lammable Sol1as ·1. Pyropho1ics . Cryogenics ompressed Gases • Organic Peroxides Unstable Reactivoa Highly Toxic or Toxic Materials 3. lammable or Combustible Uquid 6. Oxidizers 9. ater Reactivos adioactives PART II: COUNTY OF SAN DIEGO HEALTH DEPARTMENT· HAZARDOUS MATERIALS MANAGEMENT DIVISION: CONTINGENCY PLAN REVIEW; 6Dcorrosives @other Health Hazards If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Management Division, 1255 Imperial Avenue, 3rd Froor, San Diego, CA 92186-5261. Telephone (619) 338·2222 prior to the issuance of a OFFICE USE ONLY D RMPP Exempt building permit. FEES MAY BE REQUIRED Date Initials ~ No 1 . ~_.,,O Is your business listed on the rfiv~,rse sidG of this form? D RMPP Required Date Initials 2. ozr. D Will your business dispoae of Hazardous Substanceo or Medical WHte in any amount? 3. ~ D Will your business store or handle Hazardous SubsttinCH in quantities ·equal to or greater than 55 gallons, ---,; 500 pounds, 200 cubic feet or carcinogens/reproductive toxins in any quantity? 4. D L.:::.J Will your business use an existing or install an underground storage tank? D RMPP Completed :..:..~ D Will your business store or handle Acutely Hazardous Materials? Date Initials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT If the answer to any of the questions is yes, applicant must contact. the Air Pollution Control District, 9150 Chesapeake Drive, San Diego, CA 92123. Telephone (619) 694-3307 prior to the issuance of a building permit, YES NO 1 . D ~ill the intended occupant in1tall or use any of the equipment listed on the Listing of Air Pollution Control District Permit Categories, on the reverse side of thi1 form? 2. D c::J (ANSWER ONLY IF QUESTION 1 IS YES.) Will the 1ubject facility be located within 1,000 feet of the outer boundary of a school (K through 1 21 as listed in the current Directory of School and Community College Di1tricts, published by the San Diego County Office of Education end the current California Private School Directory, compiled in accordance with provisions of Education Code Section 331907 Bnetly describe nature of the intended bu1rne1S actlVlty: _'\2..~f?f.P,.12..C .. -L-< if½'-)V) 1:>€;.wsLQP r,,')'\S,µ"\ Laa~R..ATI),e.ceS Foe PHA-£'..!'V'-A-C€u 1/ffif--S N;,me of OwMr N Auth,:,riz""!! A~1·rat: ~<ekfrS-:$. c:S, i h..;£.\ ~!)- d Iara under penalty of perjury that to the beat of my knowledge and belief the responses made herein are true Date: CJ /,z&j k: l FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: _____________________________ _ BY:, ___________________________________ Date:, ________________ _ EXEMPT FROM PERMIT RE0U111EMENTS APPIIOVED FOR BUILDING PERMIT BUT NOT occ·uPANCY APCO APPROVED FOR OCCUPANCY COUNTY-HMMO APCO County of San Diqo Depa,1mcal of Hcallh Services FILE NO.: ----- ADDRESS. SAN DIEGO FIRE DEPARTMENT 525 B STREET. SUITE 705 SAN DIEGO. CA 112101 (1519) 533-4400 Hazardous Materials lnforn1ation BUSINESS NAME. 2292 Faraday Avenue Isis Pharmaceuticals Carlsbad, CA 92008 BUSINESS TYPE: PLAN FILE NUMBER: PHONE NUMBER: Office/R&D ( 61 9) 931-9200 The following information shall be submitted for determination of occupancy group classification and/or a CEDMAT inspection declaration. Any deviations may require reclassification of this building. --------·--························-··················-······················-·············-------- Mark any process or equipment listed below to be used inside or adjacent to building: Printing/Silkscreening Combustible Metal Chemical Storage Auto Repair Dust Producing Metal Plating Spray Painting Ovens/Kilns Dip Tanks Welding/Cutting Flow Coaters Semiconductor Fab List {on page two) all of the following hazardous materials used or stored in your business: Explosives or Blasting Agents Compressed Gases Flammable and Combustible Liquids Flammable Solids Organic Peroxides Oxidizers Pyrophoric Materials Unstable (Reactive) Materials Water-Reactive Materiais Cryogenic Fluids Highly Toxic or Toxic Materials Radioactives Corrosives Other Health Hazards ···············-···········-···---······················-·········--··-·················-·····------------------·---- I hereby certify that the use, storage, or processing of ~azardous materials will be limited as indicated on page two. Building Own~r or Responsible Party: OCCUPANCY CLASSIFICATION: DEPUTY FIRE MARSHAL: DATE: Notes: -------------------------------------- FPB-500 (Rev, 10-90) PAGE ONE . ~. FILE NO. ----- List all materials used in your business. Group according to categories specified on page one. Use Appendix VI-A, Uniform Fire Code, 1988 as a guide forclassifyii,ig hazardous materials. · QUANTITIES CONCEN-FLASH POINT IN USE IN USE TRATION CLASSIFICATION LD-50 OPEN CLOSED STORAGE LOCATION CHEMICAL NAME CAS NO. (PERCENT• (APPENDIX VI-A) pH SYSTEM SYSTEM • AGE) Please ref~r~nce the Hczardous ~aterial Analypis Report, by Mark Eriksen-Ratr~n Plan Check Fjle No. 951368, sub~itted to the ~ity of Car~sbad on Friday, September 29, 1995. ,, PAGE TWO