HomeMy WebLinkAbout1375 BUENA VISTA WAY; ; CB042564; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plumbing Permit Permit No: CB042564
--
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "feeslexactions." You have 90 days from the date this permit was issued to protest imposition of these feeslexactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified feedexactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
~
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type: PLUM Status: ISSUED
Parcel No: 1562312100 Lot #: 0 Applied: 06/25/2004
Reference #: Plan Approved: 06/25/2004
Issued: 06/25/2004
Project Title: DELUCA RES REPLACE SEWER Inspect Area:
1375 BUENA VISTA WY CBAD
Construction Type: NEW Entered By: SB
LINE
Applicant: MR ROOTER
9170 CHESAPEAK DR 92123 1800-976-6837
Owner: DELUCA DAVID T
1375 BUENA VISTA WAY CARLSBAD CA 92008
Plumbing Issue Fee
Fixture or Trap
Building Sewer
Roof Drain
InstalVRepair Water Line
Water Heater and/or Vent
Gas Piping System Vacuum Breaker Other Plumbing Fees
Master Drainage Fee
Sewer Fee
Additional Fees
TOTAL PERMIT FEES
$20.00
$0.00
$1 5.00
$0.00
$0.00
$0.00 $0.00 $0.00
$0.00
$0.00
$0.00 $0.00
$35.00
Total Fees: $35.00 Total Payments To Date: $0.00 Balance Due: $35.00
5255 06/25/04 #U2 01 02
CGP 35.00
Date: Clearance:
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE 0
PLAN CHECK NO.
EST. VAL.
Plan Ck. Depo it
Validat5d 477
n y Address (include BldglSuite X) Business Name 1st this address)
"Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total X of units
qssessor's Parcel X Existing Use Proposed Use
Name Address City State/Zip Telephone X Fax X
7
0
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
IChaoter 9. commendinn with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom, and the basis for the alleged .~ . . - 7031.5 by any applicant for a permit subjects the applicant to a civilgenalty of not more than five hundred dollars ($5001). 9/70 C#&iM%ze 3L -G~,6~ew fp 976 -@37 fl StateiZip Telephone X
City Business License X
Address
License Class
Designer Name Address City State/Zip Telephone
'ch this permit is issued.
Policy No. 1 7 0 ' oy-2m"r Expiration Dateq/Z Fd-
CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS)
0 to become subject to the Workers' Compensation Laws of California.
thousand dollan
retion coverage la unlawful, .nd .M aubjact an employer to s up to one hundr.d
0 1, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s1 licensed
pursuent to the Contractor's License Law).
0
1.
2.
3.
4. number I contractors license number):
5.
of work):
PROPERTY OWNER SIGNATURE DATE
I am exempt under Section
I personally plan to provide the major labor and materials for construction of the proposed properly improvement. 0 YES ON0
I (have 1 have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
I plan to provide portions of the work, but I have hired the following person to coordinate. supervise and provide the major work (include name I address I phone
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number I type
Business and Professions Code for this reason:
program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? . 0 YES
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
Is the facility to ba constructed within 1,OOO feet of the outer boundary of a school site? 0 YES 0 NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REOUIREMENTS OF THE OFflCE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
0 NO
0 YES 0 NO
I certify that I have read the application and atate that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEOUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Officlal under the provisions of this Code shall expire by limitation and become null and void if the building or work
the date of such permit or if the building or work authorized by such permit is suspended or abandoned
(Section 106.4.4 Uniform Building Code).
DATE &kfhL--/
WHITE: File YELLOW: Applicant PINK: Finance
City of Carlsbad Bldg Inspection Request
For: 06/30/2004
Permit# CB042564
Title: DELUCA RES REPLACE SEWER
Description: LINE
Type: PLUM Sub Type:
1375 BUENA VISTA WY Job Address:
Location:
Suite: Lot 0
APPLICANT MR ROOTER
Owner: DELUCA DAVID T
Remarks: PM PLEASE - THE LINE IS EXPOSED
Inspector Assignment:
Phone: 76064471 07
lnspec 4L r:
Total Time: Requested By: GARY
CD Description Act Comment
Entered By: CHRISTINE
22 Sewerwater Service
Associated PCRs/CVs
Date
InsDection History
Description Act lnsp Comments
June 29,2004
City of Carlsbad Building Inspection
Inspection Services
Carlsbad, Ca. 92008
n Re: Permit
The following are the procedures and standards followed for the Trenchless Sewer Line
1375 Buena vista Way, Carlsbad, Ca. 92008
Replacement at the above address.
Installation:
Installation standards as set forth in the 2000 edition of the Uniform Plumbing Code, IAPMO
Standard IS 26-99. Trenchless Polyethylene Pipe For Sewer Laterals as well as all other sections of applicable code have been followed as necessary.
Excavation:
Three areas of excavation exist. One entry point from which the pipe is pulled, where the pulling head enters the existing pipe, one exit point where the resistance or backing plate,
pulley and hydraulic pulling ram is set and the new pipe is pulled from, and one additional
connection to tie-in an existing drain line fmm the dwelling. The excavations are in non-traffic
areas.
Materials:
The building sewer was replaced using the TRlC Trenchless Technology system. The existing line was a 4" cast iron and vitrified clay line that was replaced using UPC approved, 4" HDPE
3408, SDR 17pipe.
Methods of Joining:
The butt joints connecting SDR 17 pipe to pipe are bonded using the heat fusing method, as
per ASTM D2657/D3261 standard and manufactures specification at a temperature range of
400 to 450 degrees Fahrenheit. Other connections made to existing lines are as per 2000
edition of the Uniform Plumbing Code 705.1.6 and 705.1.8, for molded and shielded
couplings.
Pipe Replacement:
The pulling head swaged cable is connected to the pulling head, the head is inserted into the
existing pipe. The pipe is pulled at a rate of approximately one foot per minute at a pressure
dhs not exceed 3200 psi. SO as to ensure that the manufactures specification of pulling
ressure is not exceeded. (Approximately 3300 to 3500 psi.)
Cleanouts are installed in the systems as per UPC section 707.
Inspection and Testing:
The completed job has been video inspected to insure that the line is intact and no low spots
exist. Further, there will be a flow test to insure the proper flow is not impeded in any way.
Backfill:
The excavations are to be backfilled, upon passing Building Official inspection with dean
native soil and compacted.
The foregoing is a true and accurate account of the materials and procedures used to
complete the work as outlined herein and is a self certification of the proper completion of the work as per currently adopted UPC standards.
Respectfully Submitted, hi Gary RamG