Loading...
HomeMy WebLinkAbout1662 CALLIANDRA RD; ; CB011715; PermitCity of Carlsbad . 1635 Faraday Av Carlsbad, CA 92008 Building Inspection Request Line (760) 602-2725 05/23/2001 Retaining Wall Permit Permit No:CBOI 171 5 NOTICE Please take NOTICE that approval of your project indudes the 'Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'feeslexactions." You have 90 days from the date this permit was issued to protest imposition of these feeslexactions. If you protest them, you must folkw the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for pmcessing in accordance with Carlsbad Munidpal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposhn. You are hereby FURTHER NOTIFIED that your right to protest the specified feeslaxadions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other simibr application promsing or service fees in connedion with this project NOR DOES IT APPLY to any , feeslexactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously othemise expired. Job Address: Permit Type: RETAIN Status: ISSUED Parcel No: 21 5900 1 900 Lot #: 0 Applied: 05/10/2001 Valuation: $6,300.00 Construction Type: NEW Entered By: JM Reference #: Plan Approved: 05/23/2001 Issued: 05/23/2001 Project Title: SERENATA- CRIB RETAIN WALL Inspect Area: Applicant: RETAINING WALLS CO 110 1800 THlBlDO ROAD 1662 CALLIANDRA RD CBAD WITH CALCS 400 SF VISTA CA 92083 760-599-9595 m3.1)5/23/01 0002 01 02 CGF 77-59 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Strong Motion Fee Renewal Fee Add'l Renewal Fee Other Building Fee Additional Fees TOTAL PERMIT FEES $327, I FINAL APPROVAL I I Inspector: Date: 7 /GcD/ Clearance: !I PERMIT APPLICATIPN CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK-NO. EST. VAL. 6s&? Validated By Date Legal Description Lot No. Subdivision NameINumber Unit No. Phase No. Total t of units Assessor's Parcd t Existing Use Proposed Use Description of Work 2s- 900 - 19 3 6z- Pr/6 /B CA &#a th,ml de// SO. FT. #of Stories t of Bedrooms t of Bathrooms -- (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Codel or that he IS exempt therefrom, and the basis for the alleged violation of Section 7031.5 by any applicant for a per it subje ts the applican to a civil penalty of not more than five t), fi-4 ,FA 9-3 nu &UQ %hid 10 2 d. ,, J& // 1 Statezip cfiv / Address 1J4f/r I2 State License t 6/<& 7r License Class A City Business License I /d-0&0 7s /city Statelzip Telephone Designer Name Address 3 766/m9 - 6767 rps ,&and/ e /Bo/ n,& .&d , -& .= ~ drs/a , r4 State License t C JJOB & 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. @ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is insurance carrier and policy number are: (THIS SECTION NEED NOT BE COMPLET~IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$io01 OR LESS) E* e/& Policy NO. #UC t6 ? 6//5/08 Expiration Date 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to s ure workers' compensation coverage is unlawful. and shall subject an employer to crimlnal penalties and civil fines up to one hundred thousand dollars ($IO&~. In adbn t&t-st of compensation. damages as provided for in Sactlon 3706 of the Labor codeJnterest and attorney's fees. I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 1, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 1. 2. 3. I am exempt under Section I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ON0 I (have I have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number): Business and Professions Code for this reason: 4. number I contractors license number): 5. of work): PROPERTY OWNER SIGNATURE DATE I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated [include name I address I phone number I type program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 0 YES 0 NO 0 YES LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit) of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenc d within 180 days from the date of such permit or if the building or work authorized by such permit IS suspended or abandoned at any time after the work is m or a period 180 day ection 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE l?f&?d--L DATE lr/#/e WHITE: File YELLOW: Applicant PINK: Finance Inspecti'on List Permit#: CBOl1715 Type: RETAIN SERENATA- CRIB RETAIN WALL WITH CALCS 400 SF Date Inspection Item Inspector Act Comments 09/06/2001 65 Retaining Walls RI 09/06/2001 65 Retaining Walls RB AP 09/06/2001 69 Final Masonry RB AP FINAL SOILS REPORT COMPLETE 09/04/2001 69 Final Masonry RI 09/04/2001 69 Final Masonry RB NR 08/29/2001 69 Final Masonry RB co ND CONTINOUS & FINAL APPROVAL BY GEOT. Thursday, September 13,2001 Page 1 of 1 4 - Carlsbad 01-1715 5/21/01 TOTAL VALUE Jurisdiction Code VALUATION AND PLAN CHECK FEE 6,300 cb By Ordinance JURISDICTION: Carlsbad PLAN CHECK NO.: 01-1715 Plan Check Fee by Ordinance PREPARED BY: David Yao DATE: 5/21/01 v BUILDING ADDRESS: 1662 Calliandra Road Type of Review: a- 0 Structural Only Repetitive Fee Repeats 0 Other 0 Hourly n Hour * Esgil Plan Review Fee I $56.761 I $45.41 I Comments: Sheet 1 of 1 macvalue.doc c EsGil Comoration DATE: 5/21/01 JURISDICTION: Carlsbad PLAN CHECK NO.: 01-1715 PROJECT ADDRESS: 1662 Calliandra Road PROJECT NAME: Retaining Walls Ixl 0 0 0 0 Ixl 0 IXI 0 FILE SET: I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: REMARKS: The applicant hand carried the approved plan back to the city.(O.K. per Mike Peterson) Mail Telephone Fax In Person By: DavidYao Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 511 4 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858) 560-1468 4 Fax (858) 560-1576 I City of Carlsbad BUILDING PLANCHECK CHECKLIST RETAIN1 NG WALL BUILDING PLANCHECK NUMBER: CB L)//7/ 5 BUILDING ADDRESS: /b 62 /,. PROJECT DESCRIPTION: Retaining Wall ASSESSOR’S PARCEL NUMBER: 2 S-qCp - (9 ENGINEERING DEPARTMENT APPROVAL DENIAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore, any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. By: Date: AlTACHMENTS Right-of-way Permit Application Please see Make necessary corrections to plans and/or specifications to this office for review. Date: &A Date: Date: &A Date: I BY: Date: ENGINEERING DEPT. CONTACT PERSON NAME: JOANNE JUCHNIEWICZ City of Carlsbad ADDRESS: 1635 Faraday Avenue Carlsbad, CA 92008 PHONE: (760) 602-2775 bCA r2z8-7314 (760) 602-2720 FAX (760) 602-8562 @ - BUILDING PLANCHECK CHECKLIST RETAINING WALLS 1STJ 2NDJ 3RW CI Q CI 1. Provide a fully dimensioned site plan drawn to scale. Show: A. NorthArrow D. Easements B. Existing & Proposed Structures E. Retaining Wall C. Property Lines (dimensioned from street) (location and height) CI Q 0 2. Show on site plan: A. Drainage Patterns B. Existing & Proposed Slopes C. Existing Topography p'"" wacz 0-9- P CI CI 3. Include on title sheet: A. Site Address B. Assessor's Parcel Number C. Legal Description D. Grading Quantities Cut Fill ImporVExport (Grading Permit and Haul Route Permit may be required) CI CI Q 4. Project does not comply with the following Engineering Conditions of approval for Project No. Conditions were complied with by: Date: P CI P 5. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-way and/or private work adjacent to the public Right-of-way. A separate Right-of-way issued by the Engineering Department is required for the following: Please obtain an application for Right-of-way permit from the Engineering Department. Page 1 PLANNINGIENGIN~ERING APPROVALS PERMIT NUMBER CB 0 // 7/(n DATE s/(/m i RESDENTIAL I TENANT IMPROVEMfiNT CARLSBAD COMPANY STORES VILLAGE FAIRE h COMPLETE OFFICE BUILDING' OTHER i. PLANNER DATE L8Geotechnics L Incor~oxated COQh oat8 Deswlption 1 12/12/00 Supplemental Retaining Wail Recommendations Aviara Phase Ill, PA 21 A b D 111 Carlsbad. California + - 9245 Advhy Rord, Suite 103 San Diego, CA 92126-4442 @om: (619) 536-1000 FAX (619) 536831 1 LETTER OF TRANSMITTAI, TO: Retainlng Walls Co. North DAT& Decmber 13,2600 % ATTENTION: Eduorda Ruvrlcabr REGARDING: 0-1300 GEOtECHNlCS PROJ. NO. 02309oJ-02 We am Irarmlttlng th@ following attached ibms by: - Expu Maii Cllont Pick-Up - Remaw: Please call if you have any questions. i Copy To: Brehm Oesign Center, Ms. Kristin Cwlson DEC-13-2000 13:52 - lrltcrnd Friction Angle, + Cobcsion @st) TOW Unh Weight @cf) r- 34O 34' 0 0 133 133 - e Geotechnics -1 n c o r p o r at e d Geotechnics -1 n c o r p o r at e d December 12,2000 Brehm-Aviara 111 Development Associadon, L.P. do Ms. Kristin Caulson hhm Design Center 5770 Obulin Drive San Diego, California 921 2 I Project No. 0230-005-02 Documcnt No. 0- 1300 SUBJECT: SUPPLEMENTAL RETAINING WALLaRECOMMENDA"IONS Avian Pbme MI, PA 21 A&D SI1 Carbbrd, California Refnaace: atotechnics Jncorpmued (2000). Retaining Wuil Rcconmzcradat;ons. Aviara Phase I4 PA 21 ABtDI3. Curlsbad, Cal~firnla, Project No. 0230-005-02, Document No. 09765, July 26. Dei Ms. Coulson: As requested, this letter provides soil parameters for ret9idng wall design nqutsted by Reraining Walis Company North. The parameters provided bin arc based on cwr gnviow analysis of the siw conditions premred in the rcferenL%d fetter. Wc understand thc walls ace proposed at the top of the existing 2: I (horizontal:venical) fill slopes at the rear of lots 85.86, and 88. Our analysis is based on amaximurn WaIl height ofapproximately 6 &et. The following parameters may be used fbr the design of the proposed Criblock walls. Retained and Foundation Reirrfoxced Zone An inrd m'crion an& of 38O may bc assumed for the reinforcecl zone if hpond crushed aggregate basc mnxerial is used. An allowable bearing capacity of 1.500 psf may be used for design, based on a minimum depth of embedment of 2.5 feet into dcnse, compacted fill measad wnically fiom the outside bottom edge of the foundation member tc, the slop hce. Footing excavations should bc obscrvd by a rcpmsentativc of our firm to evaluate whether the Wing mattrials are as assumcd in our analysis. The inclination of temporary hck-cuts should not exceed 1:1 (horimnta1:vcrtical). We have Dssumed that the soil grade in fkont of the dl will be rnainfaincd to dcsip grade. Surcharge loads and hybostalic prcsswcs were not included b our analysis. If these arc applicable, we should be contacted for revirions to the recommendations provided hcrrin. Backfill material should be compacted to at least YO percent of rhe laboratory maximum dry density in accordance with ASTM D 1557. If importsds MC ucd for wall backfill, they should bc text& by Geotechnics Incozporatcd to compare the &ear s%ength and unit weight Wws to nctual design dues. We recommend the mils used as backfill be predominantly firce draining, graaul~~, free of organic and clay materials, and haw a very low expansion potmlial (Expansion Index of 20 or less). Adequatc drainage should be provided to relieve hydrostatic pressures. The recommendations prescntedherein are considered generally consistent with meduds typically used in southm California, and have been develupcd wing the hree of cpT4 and skill ordinarily exercised, under simiilar circumstanccs, by reputable geoteehnical consuhants practicing in this or similar localities. No other warranty, expressed or impSicd, is made as to the conclusions end professid opinions included in this letter. Gcotcchdcr facorporatd BR€WM--A\II.&A Ill DEVELOPMENT ASSK., L.P. PROJECT NO. 0230-WS-02 I>ECEMBKR 12,2000 DOCUMENT NO. 0-1300 PAGE 3 We appreciate chi$ opparmnity to be dcontiniicd scrvicc, Please f-1 lee to call with any qucstions or comments. GROTECHNICS INCORPORATED David Padilla, P.E. 55974 Project Engineer W. Lee Vanderhwt, C.E.G 1 125 Principal Reviewed by: 0- Anthony F. Beltkit, P.E. 40333 Principal NBIWLVIDP Distribution: (1) Addressee (FAX ONLY: 858-453-5442) (I) Retaining Walls Company North, Attn: Eduar& Ruvdcaba (FAX ONLY: 858-453-3056) , * Geotcehalco lncurporatcd TOTfiL P.B4 4 c i. i.. EARTH RETENTION CALCULATIONS March 13,2001 SHEETlOF I/ PREPARED BY: OWEN ENGINEERING GROUP 1800 THIBODO STREET SUITE 320 VISTA CA 92083 760-599-6767 PREPARED FOR: RETAINING WALLS COMPANY NORTH 1800 THIBIDO DRIVE SUITE 110 VISTA CA 92083 (760) 599-2500 PROJECT CONTACT: PREPARED FOR CHARLIE EATON BREHM COMMuNlTlES 5770 OBERLIN DRIVE SAN DIEGO, CA 92121 SITE: SOIL DATA FROM: REPORT DATED: PROJECT NUMBER SERENATA CARLSBAD, CA CARLSBAD TRACT 92-3 GEOTECHNICS, INC 9245 ACTIVITY ROAD SAN DIEGO, CA 92701 LETTER DATED 12/ 1 2/2000 023 0-005 -02 ......................................................... VOTE: THESE STRUCTURAL CALCULATIONS ARE ONLY VALID FOR USE BY RETADlTh MALLS COMPANY NORTH. IT IS REQUIRED AS A CONDITION OF THESE STRUCTtW :ALCULATIONS, THAT A MEMBER OF THE RETAINING WALLS COMPANY NORTH STAF TELD INSPECT AND APPROVE THE CONSTRUCTION OF THIS PROJECT. OWENENGINEERTE ?ROUP WILL NOT ACCEPT RESPONSIBILITY FOR ANY PROJECT RELEASED WITH01 KRITTEN FINAL APPROVAL FROM RETAINING WALLS COMPANY NORTH. 'OB NO. 99-09-02 CONTENTS RETAINING WALLS LOCATION CRIBWALL DETAILS & NOTES CRIBWALL CALCULATIONS 3 4-8 9- 11 NOTES: THE SOILS ENGINEER SHALL INSPECT AND APPROVE THE TEMPORARY BACKCUT AND FOUNDATION EXCAVATION PRIOR TO CONSTRUCTION. THE SOILS ENGINEER SHAL,L INSPECT AND APPROVE ALL WALL DRAINS. THE DESIGN ENGINEER MUST BE NOTE'Y BY THE SOILS ENGINEER IN THE EVENT THAT THE SOIL CONDITIONS ENCOUNTERED DO NOT MEET THE PARAMETERS USED HEREIN. HEAVY EQUIPMENT SHOULD BE KEPT 3 FEET BACK FROM THE RETAINING WALL AT ALL TIMES. \ THESE CALCULATIONS ARE BASED UPON A MINIMUM ANGLE OF INTERNAL J?RICTION OF 34 DEGREES FOR THE RETAWED AND FOUNDATION SOILS. THE SOILS ENGINEER SHALL VERIFY AND APPROVED THE BACKFILL SOIL PARAMETERS DURING CONSTRUCTION. . .. I800 THIBODO RD. all0 VISTA, CA. 92083 (760) 599-9595 GROUND LINE TOP OF WALL 1240 WEST llTH St. CRIB RETAINING WALL STANDARD DETAIL TRACY, CA. 95376 CK (209) 832-2600 DETAIL NO. XL-1 4 GROUND 1 DRAINAGE TO BE SPECIFIED BY SOILS ENGINEER. MANUFACTURER ADVISES AS A MINIMUM A 4 INCH PERFORATED PVC SUBDRAIN ENCASED IN 3 CU FT/FT OF 3/4" CRUSHED ROCK WRAPPED IN FILTER FABRIC. CRIBLOCK '' RETAINING WALL LEVEL BACKFILL TYPICAL SINGLE DEPTH X-SECTION NO SCALE FALSE HEADER 1 ALTERNATING BACK STRETCHER I FRONT STRETCHER (TYPICAL) CRIBLOCK RETAINING WALL TYPICAL SINGLE DEPTH PLAN VIEW BASE COURSE 5.0' HEADERS NO SCALE 800 THIBODO RD. #llO VISTA, CA. 92083 (760) 599-9595 1240 WEST llTK St. TRACY, CA. 95376 (209) 832-2600 DETAIL NO. B-1 a 3 LL 0 a 0 I- ‘T c 7 3 LL 0 W i! E a a a I m iE;“ u W v) . L 4 FRONT STRETCHER - 0.375" 5.9' 4 -0.375" # 4 REBAR -01.5" -z---- 6.0". - - 8.OU - 1.5" CLR. (TYP.)i ' BACK STRETCHER CLR. (W.1 HEADER SOUTHERN OFFICE 1531 GRAND AVENUE JAN MARCOS, CA. 92069 (619) 471-2500 RETAINING WALLS co. N, NORTHERN OFFICE ' 800 E. GRANT LINE RD. CRIB RETAINING WALL STANDARD DETAIL DETAIL NO. M-5 CA. 95376 C K (209) 832-2600 TOP VIEWS 1.5" CLR. (NP.)-A ' 0.75" 2.0" RAD. (TYP.)l 0.25" 0.25" 1 .on- FALSE HEADER NOTES: 1. STRENGTH OF MATERIALS f'c = 3250 PSI fy = 60.000 PSI A. COMPRESSIVE STRENGTH OF CONCRETE 6. YIELD STRENGTH OF STEEL CRIBLOCK ty RETAINING WALL MEMBERS DIMENSIONS (5.0' HEADERS) NO SCALE .. .... i... CRIBLOCK lM RETAINING WALL GENERAL NOTES DESIGN 1. DESIGN IS BASED UPON PLANS, TOPOGRAPHY AND SOILS DATA SUPPLIED BY OTHERS ASSUMED AS CORRECT. RETAINING WALLS COMPANY N. SHALL NOT BE HELD RESPONSIBLE FOR COSTS INCURRED DUE TO VARIATION IN ACTUAL FIELD CONDITIONS. 2. STABILITY CALCULATIONS ARE VALID ONLY FOR ’LOAD CONDITION SHOWN. 3. FIELD TESTING OF SOILS FOR VERIFICATION OF SOILS PARAMETERS IS NOT THE RESPONSIBILITY OF RETAINING WALLS COMPANY NORTH. RETAINING WALLS COMPANY NORTH DOES NOT EMPLOY PERSONNEL TRAINED TO PERFORM SUCH TESTING. 4. ALL STRUCTURAL LOADS BEHIND THE WALL MUST REMAIN BEYOND A 45 DEGREE INFLUENCE LINE EXTENDED FROM THE HEEL OF THE WALL TO THE GROUND SURFACE, UNLESS SPECIFICALLY DESIGNED FOR BY RETAINING WALLS COMPANY NORTH. 5. RETAINING WALLS COMPANY NORTH DOES NOT ANALYZE GLOBAL STABILITY. RETAINING WALLS COMPANY NORTH SHALL NOT BE RESPONSIBLE FOR GLOBAL STABILITY OF THE WALL AS PROPOSED. DRAINAGE AND EROSION CONTROL 1. UNLESS SPECIFICALLY COVERED IN CONSTRUCTION CONTRACT, ALL DRAINAGE AND EROSION CONTROL IS TO BE INSTALLED BY OTHERS. 2. DRAINAGE BEHIND WALLS SHALL BE -SPECIFIED BY SOILS ENGINEER. MANUFACTURER ADVISES AS A MINIMUM A 4 INCH PERFORATED PVC SUBDRAIN ENCASED IN 3 CU FT/FT OF 3/4” CRUSHED ROCK WRAPPED IN FILTER FABRIC. 3. A CONCRETE DITCH IS RECOMMENDED AT THE TOP OF CRIBWALLS SUPPORTING SLOPED EARTH TO PREVENT POSSIBLE EROSION FROM IRRIGATION OR STORM RUNOFF SPILLING OVER THE FACE. 4. EROSlON CONTROL AND MAINTENANCE OF DRAINS SHALL BE THE RESPONSIBILITY OF THE OWNER. MISCELLANEOUS 1. BACKFILL WITHIN AND BEHIND THE WALL SHALL BE 2. PLANTING AND IRRIGATION OF WALLS TO BE DONE 3. MAINTENANCE OF WALL SHALL BE THE RESPONSIBI COMPACTION OF 90%. PLACED AT MINIMUM RELATIVE BY OTHERS. .ITY OF THE OWNER.. 4. AS-BUILT WALL SAFETY, SUCH AS INSTALLATION OF FENCING OR GUARDRAILS IN AREAS ACCESSIBILITY TO PEDESTRIAN OR VEHICLE TRAFFIC, IS THE RESPONSIBILITY -~ ~~ OF THE OWNER. 5. RETAINING WALLS COMPANY NORTH. STANDARD PLANS AND STANDARD SPECIFICATIONS ARE A PART OF THIS DESIGN. 6. AGENCY REQUIREMENTS WHICH EXCEED THE REQUIREMENTS OF THIS DESIGN SHALL GOVERN. 7. UNLESS SPECIFICALLY ADDRESSED IN THE DESIGN, WALLS SHALL NOT BE CONSTRUCTED IN WATERWAYS OR IN AREAS SUBJECT TO FLOODING. DETAIL NO. GN-1 1 I CRIBWALL STABILITY CALCULATIONS Sheet 9 of Date 3-13 -0 i I. 4457 .. I 4 C K TT \ c G CRIBWALL STABILITY CALCULATION JOB NUMBER: 99-09-02 Sheet P of // Date 7-I3-OT- ............................................................................ (1) OVERTURNING P1 = 34(12.50)2(38) = 2968; Mo = P1( 3.02) = 8973 W1 = %( 4.57) ( 1.14) (133) = 347; M1 = W1( 5.47) = 1899 W2 = ( 4.71) (10.00) (138) = 6500; M2 = W2( 3.50) = 22732 P2 = Pl(O.00) - - 0; M3 = P2( 6.99) = 0 CFV = 6847; CMr = 24631 Overturning Safety Factor = CMr/Mo = 24631/ 8973 = 2.74 (2) SLIDING a = 14.0363O sina = 0.2425 cos@ = 0.9701 RESISTING FORCE=[Plsina+CFvcosa] ( p )+ CFvsina+ PASSIVE+ COHESION = [ 720+ 66421 (0.58) + 1661+ O+ O= 5931 INDUCING FORCE = PlCOsa = 2879 Sliding Safety Factor = 5931/ 2879 = 2.06 (3) LOCATION OF FORCE RESULTANT 1.57 e H e 3.14 H = ( 24631 - 8973) / 6847 = 2.29 FT. (4) FOUNDATION PRESSURES TOE PRESSURE = [4 ( 4.57) -6 ( 2.29) 3 * 6847/ ( 4.57) 2= 1494 PSF HEEL PRESSURE = [6( 2.29)-2( 4.57)]* 6847/( 4.57)2= 1503 PSF ............................................................................ .. RANKINE FORMULA FOR ACTIVE & PASSIVE PRESSURE COEFFICIENTS Angle of Friction Angle of Slope Above 4 := 34.deg p := 0-deg Maximum Density y := 133-pcf ACTIVE EARTH PRESSURE COEFFICIENT: ACTIVE EARTH PRESSURE: Pa := Ka-y PASSIVE EARTH PRESSURE COEFFICIENT: PASSIVE EARTH PRESSURE: Pp := Kp*r Ka = 0.2827 Pa = 38pcf Kp = 3.5371 Pp = 470pcf