Loading...
HomeMy WebLinkAbout2152 AVENIDA TORONJA; ; CB981847; Permitb& 5'3a%l! I L D I N G P E R M I T Permit No: CB981847 06/19/98 13: 20 Project No: A9802449 Page 1 -bf 1 Development No: DEV89110 Job Address: 2152 AVENIDA TORONJA Suite: Permit Type: SINGLE FAMILY DWLNG - DETACHED Parcel No: 255-261-13-00 Lot#: 166 Valuation: 207,451 Construction Type: VN Occupancy Group: Reference#: CT88-03 Descripti*-~n: PLAN 3,PHS 4,2317+699 GAR+86 : DECK+4R SF PORCH,VILLAGE Q,LA COSTA,KAUF Entered By: RMA Appl/Ownr : KAUFMAN & BROAD 619 259-6000 12626 HIGH BLUFF DR ## 400 SAN DIEGO CA 92130 Plan Check Numbers > ORIG 972911 PCK 981304 *** Fees Required *** *** Fees Collected & Credits *** __-_--__---__--------------- Fees : Adjustments: Total Fees: Fee description Number of Bedrooms Number of Bathrooms Building Permit Plan Check Strong Motion Fee Enter Plan Check D Enter "Y" to Autoc Enter "Y" to Autoc Payoff Fee for CFD Enter LFM Fee (Zone Enter "Y" for Plumb1 Each Plumbing Fixture Each Building Sewer Each Install/Repai Each Water Heater and/or Gas Pipiriy System Each Vacuum Breaker Enter "Y" for Electric Issue Fee > Single Phase Per AMP > 125 .25 Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts/Heat Pumps > 2 9.00 Each Install Fireplace > 1 6.50 Each Exhaust Fan > 1 6.50 Each Install/Reloc Vent > 2 4.50 .oo .00 11,215.83 Ext fee Dat.a 4.00 2.75 999.00 649.00 21.00 -52.00 3776.00 Y 550.00 Y 4698.83 310.00 20.00 Y 98.00 15 00 7.00 7.00 7.00 14.00 10.00 Y 31.25 15.00 Y 18.00 6.50 6.50 9.00 ________________ 2075 Las palmas Dr., Carl~bad, CA 92009 (619) 438-1161 FINAL BUILDING INSPECTION - DEPT: BUILDING ENGIAEERING FIRE PLANNING CMWD ST LITE prm CHECK#: ~~981847 DATE: 10/08/98 PERMIT#: CB981847 PERMIT TYPE: SFD PROJECT NAME: PLAN 3,PHS 4,2317+699 GAR+86 DECK+48 SF PORCH,VILLAGE Q,LA COSTA,KAUF ADDRESS: 2152 AVENIDA TORONJA CONTACT PERSON/PHONE# : C/HAFtOLD/436-6517 SEWER DIST: LC WATER DIST: 0 Lot# 166 “’Y 1 DATE P?F INSPECTED: /ayJ-fp APPROVED I/ DISAPPROVED - INSPECTED BY: INSPECTED DATE BY: INSPECTED : DISAPPROVED - APPROVED - INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - COMMENTS : FINAL BUILDING INSPECTION - DEPT: BUILDING ENGINEERING FIRE PWWNING CMWD ST LITE PLAN CHECK#: CB981847 DATE:. 10/08/98 PERMIT#: CB981847 PERMIT TYPE: SFD PROJECT NAME: PLAN 3,PHS 4,2317+699 GAR+86 DECK+48 SF PORCH,VIUAGE Q,LA COSTA,KAUF ADDRESS: 2152 AVENIDA TORONJA Lot# 166 CONTACT PERSON/PHONE#: C/HAROLD/436-6517 SEWER DIST: LC WATER DIST: 0 INSPECTED DATE BY : !& INSPECTED DATE BY: INSPECTED : INSPECTED: I b - L 5.4g APPROVED - c/ DISAPPROVED - APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - COMMENTS : FINAL BUILDING INSPECTION - DEFT: BUILDING ENGINEERING FIRE PLANNING CMWD ST LITE PLAN CHECK#: CB981847 DATE:. 10/08/98 PERMIT#: CB981847 PERMIT TYPE: SFD PROJECT NAME: PLAN 3,PHS 4,2317+699 GAR+86 DECK+48 SF PORCH,VIUAGE Q,LA COSTA,KAUF ADDRESS: 2152 AVENIDA TORONJA Lot# 166 CONTACT PERSON/ PHONE # : C/HAROLD/ 4 3 6 -6 5 17 SEWER DIST: LC WATER DIST: 0 j . 16 1998 INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - COMMENTS : FINAL BUILDING INSPECTION - DEPT: BUILDING ENGINEERING FIRE PLANNING CMWD ST LITE PLAN CHECK#: CB981847 DATE: 10/08/98 PERMIT#: CB981847 PERMIT TYPE: SFD PROJECT NAME: PLAN 3,PHS 4,2317+699 GAR+86 DECK+48 SF PORCH,VILLAGE Q,LA COSTA,KAUF ADDRESS: 2152 AVENIDA TORONJA Lot# 166 CONTACT PERSON/PHONE# : C/HAROLD/436-6517 SEWER DIST: LC WATER DIST: 0 INSPECTED DATE BY: INSPECTED: /0//4i APPROVED DISAPPROVED - INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - COMMENTS : c CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB981847 FOR 10/16/98 INSPECTOR AREA NF DESCRIPTION: PLAN 3,PHS 4,2317+699 GAR+86 PLANCK# ORIG 972 TYPE: SFD CONSTR. TYPE VN JOB ADDRESS: 2152 AVENIDA TORONJA STE : LOT: 166 APPLICANT: KAUFMAN & BROAD PHONE: 619 259-6000 CONTRACTOR: PHONE : OWNER: PHONE : DECK+48 SF PORCH,VILLAGE Q,LA COSTA,KAUF OCC GRP REMARKS: R/436-6517 SPECIAL INSTRUCT: INSPECTOR jLJF TOTAL TIME: CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical A- - ***** INSPECTION HISTORY ***** DATE 100798 100698 090398 082798 082698 081298 070998 070898 070898 070798 062598 062598 DESCRIPTION Final Electrical Final Electrical Drywall/Ext Lath/Gas Test Insulation Rough Combo Roof Sheathing/Ext Shear Underground Combo Steel/Bond Beam Ftg/Foundation/Piers Underground Combo Underground/Under Floor Sewer/Water Service ACT INSP COMMENTS CA NF APPD ON 10/6 AP NF AP NF AP NF AP NF AP NF CA NF AP NF AP NF NR NF AP NF AP NF APPD ON 7/8 1 NNNYI xxxw N OII~ r 0 4444-4 SOUTHERN CALIFORNIA SOIL AND TESTING, INC. 6280 RIVERDALE STREET, P. 0. Box 600627, SAN DIEGO, CA 92160 (619) 280-4321 7200 07-09-98 07-1 0-98 07-20-98 6.00 28.27 61,000 2,160 11 2,500 Concrete Compressive Strength Test Report File Number: 9812071 Project Title: Westfield Village “Q” Project Location: 21 52 Avenida Toronja Architect: Kaufman & Broad Permit No: 981-847 Engineer: J. L. Davidson Pian File No: Contractor: Kaufman & Broad/Concrete Concepts 7201 7202 08-06-98 08-06-98 82,000 80,250 2,900 2,840 28 28 Location In Structure: Material Supplier: Superior Ready Mix Admixture(s): Time In Mixer (Minutes): Slump, Inches: 4-112 CC Temp: 0 Truck Number: 528 Ticket Number 234148 Air Temp: 0 Samples Fabricated By: JB Samples Tested By: NH Air Content: Lot 166 - South West Quad Post-Tension Slab-on-Grade Mix Designation: 35P % Laboratory Number: Mark: 166 Date Made: Date Received Date Tested Diameter, Inches Area, Square Inches Maximum Load, Pounds Compressive Strength, psi Age Tested, Days Required 28 Day Strength, psi Specimen sampling, transportation and compressive strength testing were performed by this agency in accordance with the applicable ASTM standanls. This agency makes no other warranties express or implied. Distribution: (2) Kaufman & Broad (1 ) City of Carlsbad (1) Superior Ready Mix Reviewed By: 1 George Gavit, RCE #56564 07-09d 8/6/98