Loading...
HomeMy WebLinkAboutMCUP 07-04; T-Mobile/Calavera Hills Park; Conditional Use Permit (CUP)AFF ALT ALUM ANT ASTM BOBLOC BLK'S BM B.N. B.O.C CHAM C.I.P. CIR CIRC CLR C.M.U. COL COMB CONC CONS CONT CTR D.B. DBL DET D.F. DIADIMDIVON OR O.S. DWG E?a E.N. E.O. E.O.S. EPS EOEQUIP EXTF.D. FIN F.J. FLR F.N. FND F.O. F.O.C. F.O.F. F.O.M. F.O.S.FRF.R.P. F.S. FT FTC FUT GA GALV GL G.LB. GYP H.B. H.O. HDWR H.M. HORIZ ABOVE FINISH FLOOR ALTERNATEALUMINUM ANTENNA AMERICAN SOCIETY FOR TESTING & MATERIALS BOARD BUILDING BLOCKING BEAM BOUNDRY NAILING BOTTOM OF CONDUIT CHAMFER CAST IN PLACE CIRCLE CIRCUMFERENCE CLEAR CONCRETE MASONRY UNIT COLUMN COMBINATION CONCRETECONSTRUCTION CONTINUOUS CENTER DIRECT BURIAL DOUBLE DETAIL DOUGLAS FIR DIAMETERDIMENSION DIVISION DOWN DOOR DOWN SPOUT DRAWING EXISTING EACH ELEVATION EDGE NAILING EDGE OF EDGE OF SLAB EXPANDED POLYSTYRENE EQUALEQUIPMENT EXTERIOR FLOOR DRAIN FINISH FLOOR JOIST FLOOR FIELD NAILING FOUNDATION FACE OF FACE OF CONC/CURB FACE OF FINISH FACE OF MASONRY FACE OF STUDFRAMEFIBERGLASS REINFORCEDPLASTIC FINISH SURFACE FEET FOOTING FUTURE GAUGE GALVANIZED GLASS GLUE LAM BEAM GYPSUM HOSE BIBBHEAVT DUTY HARDWARE HOLLOW METAL HORIZONTAL t.u. INSUL INT JT LAM L.NA MATL MAX MECH MED MFR MIN MIR MISC MM M.O. MTD MTL (N) N.I.C. NOM N.T.S. o.c. 0.0. OPNO OPP (P>PERI PL PLAST PTP.T.R R.D. REF REO'D REV R.J. RM R.O. R.O.W. RT SCHED SECT SHT SIM SPEC SO SQ.FT. S.S. STD STL SUSP SYM TEL-TELE TEMP THkT*BT.O. T.O.C. T.O.M. T.O.P. T.O.W. T.MA. TYP U.G. U.N.O. V.I.F. VERT V.C.T. W.P.WT W/ W/0 XFMR IPOIUL UIHMHIC.nINSULATION INTERIOR JOINT LAMINATED LOW NOISE AMPLIFIER MATERIAL MAXIMUM MECHANICALMEDIUM MANUFACTURER MINIMUM MIRROR MISCELLANEOUS MILUMETER(S) MASONRY OPENING MOUNTEDMETAL NEW NOT IN CONTRACT NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETER OPENING OPPOSEPROPOSEDPERIMETERPLATE OR PROPERTY LINE PLASTER POINT PRESSURE TREATED RADIUS ROOF DRAINREFERENCE REQUIRED REVISION ROOF JOIST ROOM ROUGH OPENING RIGHT OF WAY ROUTE SCHEDULESECTION SHEET SIMILAR SPECIFICATION(S) SQUARE SQUARE FOOT STAINLESS STEa STANDARDS STEEL SUSPENDED SYMETRICAL TELEPHONE TEMPORARY/TEMPERATURE THICK(NESS)TOP & BOTTOMTOP OFTOP OF CONCRETE OR CURB TOP OF MASONRY TOP OF PLATE TOP OF WALL TOWER MOUNTED AMPLIFIER TYPICAL UNDER GROUND UNLESS NOTED OTHERWISE VERIFY IN FIELD VERTICALVINYL COMPOSITION TILE WATER/WEATHER PROOF WEIGHT WITH WITHOUT TRANSFORMER SYMBOLS D EXISTING EXISTING TO BE REMOVED ELEVATION OR VIEW REF. 2 DCIM. NUMBER INTERIOR ELEVATION REF. ^X PROPERTY LINE EASEMENT/SETBACK LINE X X »^^ UTILITIES (SEE SITE LEGEND FOR" DESIGNATION) "FUTURE" OR "SWALE" CHAIN LINK FENCE WOOD FENCE •II I m=I RETAINING WALL PLYWOOO FRAMING MEMBER BLOCKING EXPOSED FINISH SPOT ELEVATION X/FT'—. • DRAINAGE DIRECTION (DOWNWARD) ZZZ3 BRICK SITE DRIVING DIRECTIONS FROM SAN DIEGO SOUTH: 5 NORTH. EXIT CANNON RD AND GO RIGHT HEADED EAST. BEAR LEFT AT COLLEGE BLVD. THEN TURN LEFT AT CARLSBAD VILLAGE DR. AND QUICK LEFT ON GLASGOW, PARK ON RIGHT. NOT TD SCALE ^g 8001 THOMAS BROTHERS GUIDE, PAGE * 1106 GRIDi F4 ^j REPRODUCED PER THOMAS GUIDE DIGITAL EDITION, END USER LICENSE AGREEMENT) TO NOT EXCEED 250COPIES. PROJECT DESCRIPTION THIS PROJECT CONSISTS OF AN UNMANNED TELECOMMUNICATIONS FACILITY TO INCLUDE THE FOLLOWING: RENEWAL OF EXPIRED PERMIT 95-0350-017 CONSISTING OF (6) EXISTING ANTENNAS & (2) BTS CABINETS AND ASSOCIATED EQUIPMENT. EXISTING CARRIERS: T-MOBILE, CINGULAR WIRELESS PROJECT SUMMARY OWNER: CITY OF CARLSBAD CITY HALL CARLSBAD, CALIFORNIA LEASE AREA: 170 SO. FT. BUILDING SUMMARY: OCCUPANCY CLASSIFICATION: B-2 TYPE: V-N SPRINKLERS: YES APN: 167-101-34-00 167-101-35-00 ADA COMPLIANCE: NOT APPLICABLE PER TITLE 24 SECTION 1105(B) .3.4.2 CONSTRUCTION TYPE: UBC 2001 CLASSIFICATION: - CONSTRUCTION TYPE: V-N CODE COMPLIANCE ALL WORK AND MATERUVLS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1. CALIFORNIA BUILDING CODE (INCL TITLES 24 & 25} 2001 2. UNIFORM MECHANICAL CODE 2000 3. ANSI/BA-222-F LIFE SAFETY CODE NFPA-101-1990 GOVERNING JURISDICTION: AREA OF EXISTING CONSTRUCTION: AREA OF EXISTING PROPERTY: EXISTING BUILDING COVERAGE: AREA OF EXISTING LANDSCAPING: EXISTING OCCUPANCY TYPE: EXISTING CONSTRUCTION TYPE: EXISTING LAND USE: PROPOSED LAND USE: EXISTING FIRE SPRINKLER SYSTEM: HEIGHT OF EXISTING CONSTRUCTION: AREA OF PROPOSED CONSTRUCTION: PROPOSED OCCUPANCY TYPE: PROPOSED CONSTRUCTION TYPE: PROPOSED FIRE SPRINKLER SYSTEM: HEIGHT OF PROPOSED CONSTRUCTION: CURRENT ZONING: NUMBER OF EXISTING PARKING SPACES: FRONT YARD: SACK YARD: SIDE YARD - INTERIOR: SIDE YARD - EXTERIOR: APPLICANT/LESSEE T-MOBILE 4. UNIFORM PLUMBING CODE 2000 5. NATIONAL ELECTRIC CODE 2002 6. CITY/COUNTY ORDINANCES 7. UBC 1997 CITY OF CARLSBAD 200 SQ FT. ±10% N/A 62 IN PARK & RECREATION TELECOMMUNICATION FACILITY N/A 60 FT. N/A a 2-N N/A N/A C2-1VL 1- - -Mobile CALAVERA PARK 2997 GLASGOW DRIVE CARLSBAD, CA 92008 SD06378 SPECIAL INSPECTIONS 1 CONCRETE 2 BOLTS INSTALLED IN CONCRETE 3 CONCRETE MOMENT-RESISTING SPACE FRAME 4 REINFORCING STEEL AND PRE STRESSING STEEL 5.1 ALL STRUCTURAL WELDING 5.2 WELD TESTING DUCTILE MOMENT-RESISTING STEEL FRAME 5.3 WELDING REINFORCING STEEL B HIGH-STRENGTH BOLTING 7 STRUCTURAL MASONRY8 REINFORCED GYPSUM CONCRETE 9 INSULATING CONCRETE FILL10 SPRAY-APPLIED FIREPROOFING 11 DEEP FOUNDATIONS (PILING, DRILLED & CAISSONS) 12 SHOTCRETE til VERIFY SOIL CONDITIONS ARE SUBSTANTOLLY IN CONFORMANCE WITH THE SOIL INVESTIGATION REPORT 13.2 VERIFY THAT FOUNDATION EXCAVATIONS EXTEND TO PROPER DEPTH AND BEARING STRATA !3.3 PROVIDE SOIL COMPACTION TEST RESULTS, DEPTH OF FILL, RELATIVE DENSITY. BEARING VALUES 13.4 PROVIDE SOIL EXPANSION TEST RESULTS, EXPANSION INDEX. RECOMMENDATIONS FOR FOUNDATIONS, ON-GRADE FLOOR SLAB DESIGN FOR EACH BUILDING SITE14 SMOKE CONTROL SYSTEM 15 SPECIAL CASES (DESCRIBE) 16 OFF-SITE FABRICATION OF BUILDING COMPONENTS 17 OTHER SPECIAL INSPECTIONS AS REQUIRED BY DESIGNER DESCRIPTION OF TYPE OF INSPECTION REQUIRED. LOCATION. REMARKS. ETC. DESIGN STRENGTH CONSULTANTS PLANCOM 302 STATE PLACEESCONDIDO. CA 92029CONTACT: KRYSTAL PATTERSONPHONE: 760-718-8703 APPROVALS THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND AUTHORIZE THE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HERON. ALL CONSTRUCTION DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT AND ANY CHANGES AND MODIFICATIONS THEY MAY IMPOSE. SHEET INDEX Tt TITLE SHEET A1 SITE PLAN A2 ENLARGED SITE PLAN A3 EQUIPMENT LAYOUT. ANTENNA LAYOUT, ANTENNA MOUNTING DETAIL A4 NORTH & EAST ELEVATIONS A5 SOUTH & WEST ELEVATIONS LEGAL DESCRIPTION REVISIONS i MSA Architecture & Planning, Inc. 6920 Miramai Rd, Suite 202 San Diego, Ca. 92121 Ph. 858530.0578 Fx. 858530.1467 San Francisco • Santa Ana • www.mu-ip.cnn SD06378 CALAVERA PARK TITLE SHEET (E) CINGULAR EQUIPMENT ENCLOUSRE (E) CINGULAR UGHT STANDARD W/ (3) ANTENNAS (1) PER SECTOR ) CALAVERA HILLS COMMUNITY PARK APN: 167-101-34-00 167-101-35-00 (E) T-MOBILE METER PEDESTAL. ELECTRICAL TRANSFORMER (POC), * TELCO PEDESTAL (POC) REVISIONS CUP RENEWAL ERM ERM MSA ArcWIedure & Hawu'ng, Me, 6920 MiramarRd., Suite 202 San Diego, Ca. 92121 Ph. 858530.0578 Fx. 858530.1467 San Francisco • Santa Ana . San Diego SD06378 CALAVERA PARK SITE PLAN T-MOB1LE ANTENNAS ANTENNAS PER SECTOR SECTORS ANTENNAS TOTAL REVISIONS CUP RENEWAL ERM ERM 0) 3 Oo -OMSA Architecture & Planning, Inc, 6920 Miramar Rd., Suite 202 San Disgo,Ca. 92121 Ri 858530.0578 Fx. 858530.1467 San Francisco • Santa Ana . San Diego SD06378 CALAVERA PARK ENURGED SITE PLAN <r SECTOR -(E) 80' HIGH SPORT LIGHTING POLE (E) LIGHT POLE (E) DISCONNECT SWITCH (E) TRANSFORMER (E) ENCLOSURE W/ B' CMU WALLS (ROOF NOT SHOWN FOR CLARITY) (E) T-MOBILE ANTENNAS (2) ANTENNAS PER SECTOR (3) SECTORS (6) ANTENNAS TOTAL (E) UTILITY TRENCH FOR POWER 4 TELCO -(E) 6070 HM GALV/PAINTED DOOR AND FRAME REVISIONS CUP RENEWAL CUP RENEWAL ERM ERU 0)IrH ^o Oo2C MSA ^rchilecfuTe & flawing, Inc. 6920 MiramarRd., Suite 202 San Diego,Ca. 92121 Ph. 858530.0578 Fx. 858530.1467 San Francisco • Santa Ana • San Diego SD06378 CALAVERA PARK EQUIPMENT AND ANTENNA LAYOUT PLAN (E) T-VOBILE ANTENNAS - (2) ANTENNAS PER SECTOR (3) SECTORS (6) ANTENNAS TOTAL (E) HM DOORS W/ LOUVERS NORTH ELEVATION (E) FIELD LIGHTS (E) T-MOBILE ANTENNAS (2) ANTENNAS PER SECTOR (3) SECTORS (6) ANTENNAS TOTAL (E) T-MOBILE LIGHT POLE SCALE:0' 4' 8'16' (E) STORAGE ENCLOSURE W/ 8" CMU WALLS- REVISIONS CUP RENEWAL ERM CRU 501 -5 1MSA"•^T^c^rrjTmr^ill/IrcWecture & Planning, Inc. 6920 MiranwRd., Suite 202 San Diego, Ca. 92121 Ph. 858530.0578 San Francisco • Santa Ana • San Diego SD06378 CALAVERA PARK ELEVATIONS SOUTH ELEVATION 1-MOBILE LIGHT POLE -(£) BUILDING .21 (E) STORAGE ENCLOSURE W/- 8" CMU WALLS (E) T- MOBILE - EQUIPMENT ENCLOSURE W/ 8" CMU WALLS BALLASTS (TYP.) (E) T-MOBIl-E ANTENNAS (2) ANTENNAS PER SECTOR (3) SECTORS (6) ANTENNAS TOTAL CE> T-MOBILE LIGHT POLE -(E) BUILDING HORIZONTAL SIDING (E) T-MOBILE EQUIPMENT ENCLOSURE W/ 8' CMU WAULS (E) HELD LIGHTS SCALE:0' 4' 8'16' ERU ERM 0)—Ir-< O .20 MSA Architecture & Planning, Inc. 6920 Miiamar Rd, Suite 202 &m Diego, Ca, 92121 Fh. 858530.0578 Saa Frandsco • Santa Ana • San Diego SD06378 CALAVERA PARK ELEVATIONS