Loading...
HomeMy WebLinkAboutDWG 524-4; 6608; FROST AVENUE DRAINAGE IMPROVEMENTS; 01-03i, I , : ~ 1! I { I ' I I ,/ i/ ;i/ I ' -- VICINITY MAP NOT TO SCALE REFERENCE ORA WINGS: FROST AVENUE & MERWIN DRIVE 1) 335-lA EVANS POINT GRADING PLANS (CT 91-3) 2) 363-3 KELLY RANCH VILLAGE E (CT 96-03) SHEET INDEX Title Sheet, Vicinity Map, and Location Map 1 Profile and Details 2 Plan 3 NOTE: CONTRACTOR SHALL LOCATE ALL EXISTING UTILITY VAL VE BOXES, MANHOLES, VAULTS, SEWER CLEANOUTS, STORM DRAIN GRATES, INLETS AND SURVEY MONUMENT BOXES AND PROTECT IN PLACE. O:\PtJbllc Wiirks\PW Common\C'-lplt11I Jmpro..monl Program Projl1:l1\8G081-NW QuQW"onl StQOll 0rQln Progrwn\A~IMI projwt1\l,lerwln Drlw\Dnign\6608..M1nrln_TltlMlw9 Plotted By. Bon}lmln Arp Pl'-11 011to; 09/01/2020 CONSTRUCTION PLANS FOR CITYWIDE DRAINAGE IMPROVEMENT PROGRAM -FROST AVENUE DRAINAGE IMPROVEMENTS - PROJECT NO. 6608 CITY OF CARLSBAD CARLSBAD, CALIFORNIA CITY COUNCIL MA TT HALL -MAYOR KEITH BLACKBURN -MAYOR PRO-TEM PR/YA BHAT-PATEL -COUNCIL MEMBER CORI SCHUMACHER -COUNCIL MEMBER SCOTT CHADWICK CITY MANAGER OCTOBER 2020 UNDERGROUND SERVICE ALERT SDG&E (GAS) SDG&E (ELEC) TIME WARNER CABLE COMMUNICATIONS AT&T CITY OF CARLSBAD (STREETS AND STORM DRAIN) CITY OF CARLSBAD (SEWER) CMWD (800)422-4133 (619)547-2020 (619)654-8686 (760)438-7741 (760)806-9809 (760)434-2980 (760)438-2720 (760)438-3891 --------PROJECT SITE f- (J) w >-_J _J I l YNC\-1 c, LOCATION MAP NOT TO SCALE RT Tl.I. DIAL rQLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALl:.RT OF SOUTHERN CALIFORNIA (FROST AVENUE STORM DRAIN IMPROVEMENTS) TITLE P E,C'D77oS EXP, c1/30/zc1cl REVIEWED BY: J)~M,Ll, /lpvr1/ INSPECTOR ' DATE \z,,/z,1 llo-Zo DATE l-----+---+-------------+---1----1----l----1~ CITY OF CARLSBAD I SHEETS I L2_j ENGINEERING DEPARTMENT 3 FROST AVENUE DRAINAGE IMPROVEMENTS TITLE SHEET, VICINITY MAP, AND LOCATION MAP l---+----+------------1----1----l-~----I APPROVED HOSSEIN AJIDEH ' ' MO ,,:~i::h y Hosse1n A11 ,.~, c,020,10,os 10/5/2020 l----+----+-------------1----l-----l----!---l ________ ____!!,,,,,,;;,; """'""'· =' ' --- l----+----+-------------1----l-----l----!---l ENGINEERING MANAGER PEC 75991 EXPIRES 6 30 22 DATE DWN BY: BA PROJECT NO. I DRAWING NO, _D_AT_E --L-IN_ITIA_L +--DA_TE--'-I_NIT_IAL-1 CHKD BY: DZ 6608 524 _4 OTHER APPROVAL CITY APPROVAL RVWD BY: DZ DA TE INITIAL ENGINEER OF WORK REVISION DESCRIPTION -·-· 6" CURB FACE (TYP) / / -----4. 5 '-----,--.------5 '--------------------'/ 1'----------,---4. 5 '-----, / I, / / . I I . I ~ •. 1 (I .· 'I • 1 I: I l . 1 I . I I ' 'L-----,.,....,.J ' . ·• ... ' . /~-TOP OF CURB 11 ✓ BEGIN LOCAL --~7 GUTTER DEPRESSION MATCH TOP OF ~-[XISTING CURB THROUGHOUT SECTION --·-·- 10" CURB FACE (TYP) • SECTION NOTES EXISTING TYPE A-4 CLEAN OUT RIM ELEV. -59. 50' FL in = 54. 6 7' GUTTER PROFILE NOT TO SCALE O100IN = 4. 92 CFS __ V100IN = 5. 60 FPS ---------7'------~ \I ~/ .....---,-, .. ,. ... ~ .... ' 'f_, • , I ·--~ --.. . . .. -. ---,___ • .. .• .. . . .. ~ . ··; .. L; . ·•·. : ·""' . , •,I-: .. df. ·-.. .· -. . ' ... . ·.,_, . _ ... .. _. .. .4 .. .,_ .. ; ... ~ :~ :._ ~..,;;,, ~ ~-~ 4-·:__1. 58.94' FL .. . 1 ' -~ ' .. ' I I 0 I I , . 1 i _J! _ _,....,--;-.,--7:--:--....--~--t. ' • ------.ji---,J------_----____ _,... --__,. ---:-:-~---:"' .. ,.-I'\. 4 .. -~ .. . ... : ... .. .. ..,... .•.·.r ':. •' :_J11,.•··4 .... .d. .......... • ... • ' . .. •. I------ ' ~ -1--~ ··-... : y / •, l.--~-,L..,..::,,.~4--__ ___,J ... '-_;•. / ... . . ~ ' ·, ~-. 4 • /". . ~ · . .-· ' · ~-" ," 4 FLout 1) PROVIDE 5" DEPTH ASPHALT CONCRETE SLOT PATCH IMMEDIATELY ADJACENT TO GUTTER SECTION PER CONSTRUCTION NOTE 7 PROPOSED TYPE A-1 CURB INLET V = 5' L = 15' Y = 4' ' ' TOP OF CURB = 59. 78' FLout -54.74' = 54. 74' EXISTING 24" RCP -~/ STORM DRAIN 3 , 6" ----------STORM DRAIN DATA TABLE NO. DIA. TYPE LENGTH NOTE SECTION NOTES 1) STRUCTURES SHOWN ARE SCHEMA TIC ONLY. REFER TO STANDARD DRAWING FOR STRUCTURAL DETAILING. 3' UPPER ZONE 95% MID ZONE 90% BEDDING ZONE 3/4" CRUSHED ROCK 90% I I ' r ' ' • STORM I I I I I I I I DRAIN PROFILE 0 18" SCALE: 0.5" = 1' *PIPE BEDDING AND I I I I ,-111--•. -~---1---:5" MIN -·12" MAX I I I I I------~ ~ ~ --~ -- 1 I _..--- 1 // - --,', I / /,,-'-'\ I / / \ \ I / / \ I ~o~cJ-~ -0-JUot6 ~~~'_---~~ SPRING LINE I :cY JU )'t:f JC JU J"-J !. ~ )' ,7 )\ ,7 ,7 1' ,7 ..,, _.1,, 5" MIN UOi .JQ(_ 0{_>0 ,_,u.__<-'-'''-'-''(L-1.)-'-'-~---------~ • I RCP 3'-6" D-1350 BACKFILL PER SECTION SHOWN PIPE BEDDING AND TRENCH BACKFILL NOTES GENERAL NOTES 1. NO REVISIONS WILL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE CITY ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE APPROPRIATE SHEET OF THE PLANS AND TITLE SHEET. 2. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT ALL TIMES DURING CONSTRUCTION. 3. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL PLAN TO THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING SLOPING OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECTION FROM THE HAZARD OF CAVING GROUND DURING THE EXCAVATION OF SUCH TRENCH OR TRENCHES OR DURING THE PIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5') OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PLAN VARIES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS, TITLE 8 CALIFORNIA ADMINISTRATIVE CODE, THE PLAN SHALL BE PREPARED BY A REGISTERED ENGINEER AT THE CONTRACTORS EXPENSE. A COPY OF THE OSHA EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION. 4. ALL OPERATIONS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR OPERATION OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED GRADING EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 8: 00 A.M. AND 5: 00 P.M. EACH DAY, MONDAY THRU FRIDAY AND NO EARTHMOVING OR GRADING OPERATIONS SHALL BE CONDUCTED ON WEEKENDS OR HOLIDAYS UNLESS APPROVED BY THE CITY ENGINEER. (A LIST OF CITY HOLIDAYS IS AVAILABLE AT THE ENGINEERING DEPARTMENT COUNTER.) 5. ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY ENGINEER FOR APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING OF WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTE OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 6. THE EXISTENCE AND LOCATION OF UTILITY STRUCTURES AND FACILITIES SHOWN ON THE CONSTRUCTION PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. ATTENTION IS CALLED TO THE POSSIBLE EXISTENCE OF OTHER UTILITY FACILITIES OR STRUCTURES NOT SHOWN OR IN A LOCATION DIFFERENT FROM THAT SHOWN ON THE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN ON THE PLANS AND ANY OTHER EXISTING FACILITIES OR STRUCTURES NOT SHOWN. 7. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES (ABOVEGROUND AND UNDERGROUND) WITHIN THE PROJECT SITE SUFFICIENTLY AHEAD OF THE CONSTRUCTION TO PERMIT THE REVISIONS OF THE CONSTRUCTION PLANS IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN CONFLICT WITH THE PROPOSED WORK. 8. THE CONTRACTOR SHALL NOTIFY AFFECTED UTILITY COMPANIES (SEE BELOW) AT LEAST TWO FULL WORKING DAYS PRIOR TO STARTING CONSTRUCTION NEAR THEIR FACILITIES AND SHALL COORDINATE WORK WITH A COMPANY REPRESENTATIVE . 9. SAWCUT ALL EDGELINES WHEN EXCAVATING INTO EXISTING CONCRETE AND ASPHALT SURFACES. LEGEND ELEV FL RCP O,oo v,oo ELEVATION FLOW UNE REINFORCED CONCRETE PIPE 100-YEAR DISCHARGE 100-YEAR YE LOCI TY UNDERGROUND SERVICE ALERT SDG&E (GAS) EROSION CONTROL & STORMWATER MANAGEMENTS NOTES 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTRACTOR WILL PROVIDE A CONTACT NAME & PHONE NUMBER BEFORE CONSTRUCTION COMMENCES. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY DEVICES WHEN RAIN IS EMINENT 3. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. 4. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 5. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREATE A HAZARDOUS CONDITION. 6. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF THE SLOPE AT THE CONCLUSION OF EACH WORK DAY. 7. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT ( 40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. ON REQUEST, THE CONTRACTOR MUST PROVIDE PROOF OF THIS CAPABILITY THAT IS ACCEPTABLE TO THE CITY ENGINEER. 8. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH i INCH MINIMUM AGGREGATE. 9. MATERIAL NEEDED TO INSTALL STANDBY BMPs NECESSARY TO COMPLETELY PROTECT THE EXPOSED PORTIONS OF THE SITE FROM EROSION, AND TO PREVENT SEDIMENT DISCHARGES, MUST BE STORED ON SITE. AREAS THAT HAVE ALREADY BEEN PROTECTED FROM EROSION USING PHYSICAL STABILIZATION OR ESTABLISHED VEGETATION STABILIZATION BMPs AS DESCRIBED BELOW ARE NOT CONSIDERED TO BE "EXPOSED" FOR PURPOSES OF THIS REQUIREMENT. 10. DEPLOYMENT OF PHYSICAL OR VEGETATION EROSION CONTROL BMPs MUST COMMENCE AS SOON AS GRADING AND/OR EXCAVATION IS COMPLETED FOR ANY PORTION OF THE SITE. THE CONTRACTOR MAY NOT CONTINUE TO RELY ON THE ABILITY TO DEPLOY STANDBY BMP MATERIALS TO PREVENT EROSION OF GRADED AREAS THAT HAVE BEEN COMPLETED. 11. THE AREA THAT CAN BE CLEARED OR GRADED AND LEFT EXPOSED AT ONE TIME IS LIMITED TO THE AMOUNT OF ACREAGE THAT THE CONTRACTOR CAN ADEQUATELY PROTECT PRIOR TO A PREDICTED RAINSTORM. 12. ALL BMPs MUST BE MAINTAINED. IF A SELECTED BMP FAILS, IT MUST BE REPAIRED AND IMPROVED, OR REPLACED WITH AN ACCEPTABLE ALTERNATIVE AS SOON AS IT IS SAFE TO DO SO. THE FAILURE OF A BMP SHOWS THAT THE BMPs, AS INSTALLED, WAS NOT ADEQUATE FOR THE CIRCUMSTANCES IN WHICH IT WAS USED AND SHALL BE CORRECTED OR MODIFIED AS NECESSARY. REPAIRS OR REPLACEMENTS MUST THEREFORE PUT A MORE EFFECTIVE BMP IN PLACE . STREET NOTES 1. ALL UNDERGROUND UTILITIES AND LATERALS SHALL BE INSTALLED PRIOR TO CONSTRUCTION OF CURBS, CROSS GUTTERS OR SURFACING OF STREETS. 2. ALL SURVEY MONUMENTS AND POINTS THAT ARE DISTRIBUTED BY THIS WORK SHALL BE REESTABLISHED, PERPETUATED, AND DOCUMENTED PER THE PROFESSIONAL LAND SURVEYORS ACT . BUILT" SDG&E (ELEC) TIME WARNER CABLE COMMUNICATIONS AT&T (800)422-4133 (619)547-2020 (619)654-8686 (760)438-7741 (760)806-9809 (760)434-2980 (760)438-2720 (760)438-3891 DIG; RT TITLE P.E. Cf571oS EXP. q/?c(zoi! ) z/cl (zrzc DATE CITY OF CARLSBAD (STREETS AND STORM DRAIN) CITY Of CARLSBAD (SEWER) CMWD " DIAL TOLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA REVIEWED BY: ))~~/ INSPECTOR [z./ z. ,, /2c12.0 DATE ~ CITY OF CARLSBAD I SHEETS I 1----1----+----------------!-----l---l----l----ll2_j ENGINEERING DEPARTMENT 3 1----1----+----------------!-----I---I----I----I FROST AVENUE DRAINAGE IMPROVEMENTS PROFILE AND DETAILS 1) SEE GS-26 FOR TRENCH RESURFACING DETAILS AND MODIFICATION PER CONSTRUCTION NOTE 7 APPROVED HOSSEIN AJIDEH H . A'' .. ~, ,,~~j~:::;"' osse,n 11 '~•• ','°20· !0,?5 10/5/2020 PIPE BEDDING ANO TRENCH SCALE: 1" -1' Q:\Publle Woor,e\PW Common\Capltol lmprovem11or1t PrO(;,'(lm Projecb\66081 C\tywlde Drainage lmpro~em011t Prt;XJr<im\AcUw, pro)ecb\l,lerwtn 0rln\DHlgn\d>11g\6608....MerwlnJ'rt1file.dwg Plotted By. Bon),:lmln Arp P!ot Date: 10/05/202.0 BA CKF'ILL 2) PAVEMENT SECTION SHALL CONSIST OF 5" ASPHALT CONCRETE OVER 6" AGGREGATE BASE 3) PERCENTAGES SHOWN ARE MINIMUM RELATIVE COMPACTION DATE INITIAL ENGINEER OF WORK DATE INITIAL DATE INITIAL REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL ENGINEERING MANAGER PEC 75991 EXPIRES 6/30/22 DATE OWN BY: BA I CHKD BY: ~P~Z __ RVWD BY· 07 . PROJECT NO. I DRAWING NO. 6608 524-4 ' \ \ \ \ \ ' \ \ \ \ \ \ \ \ J \ \ / ' \ ,/ \ \ D '" D Au PRIVA TE IRRIGATION LINE 1 l-----~\ /-1 --~~--~·"";: L ---;;/7 _6<uJ \\ ~~"'~ _ 51_1 i~_-_-_ .. ·--_-_-i-1-_•_-6 __ ·--1~·----0·----,--·c·--s· -,--,,-6' __ ·-~ ' ,, -,-, _r---1}) AT&T 1'' TELE COMM MAIN / > -"'" '-'--• ----_-:_,..___ "'" ----------~ --J/it"=_ -,l'ir' --I ~ \ ; / i ~ I I ,// ~ \\ > ,---: ,,-'"' -., ,, " -~ --., ------" :~ART ~ ~~~\,:_ li! I ---:. J~ ,, ~ ; ~ ' '"" r= 1 SDG&E 2" GAS PLA \ s \ \ \ -'°<', ~ ~~ ~~ \\ ~ \\ \--=============-~~=~= -=~-~~~= ___ =_============·-_::·--======·-=======~=-=c~~~~~~o~f=' ;~•-~;-:/1-==:~1!;-;/~~t ~~½~//21/~p;~/;?,'.:y,1/i<,~~/1/~/~~~~~~//:'7//,?/1/~/~ /, ,'./,-,_~ -/ /j /~:::::::J:::::::J ~ -~. -E,~~ ~~ SEDLEGC;RIC4-,:""'p· LA --,,,~. ~.;;-~_ ,;:-\ \ \ \ _______ _]__________ --,/ -/ 1Q I '/ '( , -// // " \ \ -·-I L . ' -,,_ ,./' ' \ \ ------------------------/ ' -,_ -7r,,7 _J 2 -, ?' --:-:::::::::::::__-::::::::::--- \ \ \ \ ----" \ \ --------11- -7---\ --------\ \ \ \ \ \ \ \ \ \ ,\-\------I ----~ ! -----------\ \ --\ \ J }----~ , r------------- -\ \ ----1-\----------_J \\ --\\ ____ 1 \_-\ \ \ \ ' \ \ \ \ ' \ \ \ \ \ \ \ \ \ \ 24" RCP STORM DRAIN '>---~ FROST A VENUE \ \ \ \ \ \ i \ \\ i1 --------------==================================---------------r--7 \ \ \\\ --------===========-----------------------------=======-==-----1 0 L ' ------------, --- ,J.L7 -----1-i-===--------)---~ )---~ t-------===------- ----------/ 7 ---·----------------... _., __ _ --·------ ----------------------------------------------=-------{9f-------=== =-== == = ===---------------------= == == = = === =--=: == -= ===== = --------\ n--' ,--_ -. --=-= =-= -=-= -_::_ = = = = = = = =-= ·1 \ ------------ -= = = = = = = = = = = = ---~-\ / / _ --___ ---------------------------------------------_ _ _ -------= = = = = ------_ __ _ I I -------------------------_____________ -------------------------__________ ------ -------------------==------- -_ _ ----_ _ I I -----------·-· ------------ "-----"< 1 8" PVC WATER ------------------------------------------------------------------------------· ------------===---~~------------,----.1------\ \ ---! r--~ = --= ----------~ I I ------ ---------------- D '" o NI 0 ,, ,- STORM DRAIN DATA TABLE NO . DIA. TYPE LENGTH NOTE 0 18" RCP 3'-6" D-1350 *PIPE BEDDING AND BACKFILL PER SECTION SHOWN Q:\PIJbl1c W«u\f'W Common\Caplld lmprnwment Program Projacb\66081 Cll),'llllde Drainage lmpro"'Mlent Pr<19ramV,,ctlve projectll\Merwln Or1ve\D.-ign\dwg\B608....M«w111J>1cm.dwg Plotted By. Benjamin Arp Plot Dote. 010/05/2020 D '"' CONSTRUCT/ON NOTES G) PROTECT IN PLACE USE CENTER OF EXISTING TYPE A-4 CLEANOUT RIM TO ESTABLISH Ci) VERTICAL CONTROL. RIM ELEVATION - 59.50' CONNECT STORM DRAIN PIPELINE TO h"\ EXISTING TYPE A-4 CLEAN OUT PER \::'_) CONNECTION WINDOW SECTION A-A OF CSO OS-9 REMOVE SIDEWALK PANELS TO THE G) EXTENTS SHOWN ANO REPLACE PER DIMENSIONS SHOWN PER SORSO G-11 CONSTRUCT TYPE A-1 CURB INLET 0 PER SORSD 0-01 (V = 5', L -15', y = 4') CONSTRUCT LOCAL GUTTER @ DEPRESSION PER DETAIL SHOWN CONSTRUCT AC SLOT PATCH TO 0 EXTENTS OF HATCHING SHOWN UNDERGROUND SERVICE ALERT SDG&E (GAS) SDG&E (ELEC) Tl f.lE WARNER CABLE CO M~UNI CATIONS AT&T CITY OF CARLSBAD (SlREETS AND STORM DRAIN) CITY OF CARLSBAD (SE\\£R) CM\\O (800)422 -4133 (619)547-2020 (619)654-8686 (760)43B-7741 (760)606-9B09 (760)434-2980 (760)43 B-2720 (760)43B-3B91 \ ~., I DI~~~~. ~ I ""'-AT LEAST TWO DA V"S ~ BEFORE YQLI om UNDERGROUND SERV ICE ALERT OF SOUTHERN CALIFORN IA ------------------1-+--- _\_______ I.I 1 I ---- / I l II --~-------I I D ' -·----~ I I '" I I , I I '-, ::r: - I I I I I ~i "AS BU I LT" _ b,,,r,v,A /J-r~y// TI TLE PE ('iS 77uS EXP. 1/3d/,yz\ REV IE WED BY: ,c)).,0:,..J /J.1 _,-,.--"7 / INSPEC TOR I z./ ZI /z_az.o DAT E '1 &/Zi/?.ol.-CJ DATE I ' i I ! ! ! I i I I I I fSHFi7 CITY OF CARLSBAD I SHEETS I 1---+--+---------------t----+--t---t---t ~ ENG I NEER I NG DEPARTMENT J 1---+--+---------------t----+--t---t---j FROST AVENUE DRAINAGE IMPROVEMENTS PLAN APPROVED HOSSEIN AJIDEH Hosse;n Ai; _ lly sjgnsd by i.filHO einAJidal1 ""O, ,o,o ,o OS 10/5/2020 E-N-GIN-E-ER-IN_G_M-AN-A-GE-R--P-EC-75-9-91-E---'XP""1R'"'Es""5"";/ID30"-l/22 DATE DA TE INITIA L ENGIN EER OF WORK REVISION DESCR IP TION DA TE INITIA L DATE INITIAL OTHER APPROVAL CITY APPROVAL OWN BY, BA I PR06J6ECOTBN O, I DR5A2W41N_G4 NO, CHKD BY: OZ RVWD BY: DZ _