HomeMy WebLinkAboutPRE 2020-0040; KELLETT ADU; Admin Decision LetterJanuary 26, 2021
Sam Wright
2911 State Street, Suite A
Carlsbad, CA 92008
SUBJECT: PRE 2020-0040 {DEV2020-0323)-KELLETT ADU
APN: 207-082-05-00
Ccityof
Carlsbad
B FILE COPY
/fJIIA/eJ 1/4 /2/
Thank you for submitting a preliminary review to add approximately 336 square feet to an existing 638-
square foot accessory dwelling unit (ADU) and 33 square feet 1:0 an existing storage area adjacent to a
three-car garage located below the ADU proposed at 4190 Sunnyhill Drive. The project site, a 31,798-
square-foot lot, currently is developed with a one-family dwelling and one ADU.
In response to your application, the Planning Division has prepared this comment letter. Please note that
the purpose of a preliminary review i~ to provide you with direction and comments on the overall concept
of your project. This preliminary review does not represent an in-depth analysis of your project. It is
intended to give you feedback on critical issues based upon the information provided in your submittal.
This review is based upon the plans. policies. and standards in effect as of the date of this review. Please
be aware that at the time of a formal application submittal. new plans. policies. and standards may be
in effect and additional issues of concern may be raised through a more specific and detailed review.
Planning:
General
1. General Plan and zoning designations for the property are as follows:
a. General Plan: Residential, 0-4 dwelling units per acre (R-4);
b. Zoning: One-Family Residential, minimum lot size 15,000 square feet {R-1-15,000)
2. The project requires the approval of a Minor Coastal Development Permit {CDP) pursuant to Carlsbad
Municipal Code {CMC) Section 21.201.080. The fee for a Minor CDP is $938. A radius map and mailing
labels for all owners within 100 feet is required to be submitted with a formal application. A postage
fee will be required at the time of application submittal. The postage fee is dependent on the number
of owners within the 100-foot radius. The City Planner will be the decision-making authority.
3. As described in the scope of work, this preliminary review application is approximately 336 square
feet to an existing 638-square foot accessory dwelling unit {ADU) and 33 square feet to an existing
storage area adjacent to a three-car garage located below the ADU. The R-1-15,000 zone permits a
detached accessory dwelling unit and recent state laws {SB 13, AB 68, AB 587, AB 670, AB 671, and AB
881) allow for the construction or additfon of an ADU above a detached garage. As designed, staff can
support the proposed additions to the ADU and storage area subject to compliance with all applicable
General Plan requirements, Carlsbad Municipal Code {CMC) standards, and state law, including but
not limited to:
Community Development
Planning Division [ 1635 Faraday Avenue Carlsbad, CA 92008-7314 [ 760-602-4600 [ 760-602-8560 f I www.carlsbadca.gov
PRE 2020-0040 (DEV2020-0323) -KELLETT ADU
January 26, 2021
Pa e 2
a. The ADU shall be architecturally compatible with the main dwelling unit, in terms of appearance,
materials and finished quality. Plans submitted with a formal application must provide the existing
elevations for the main dwelling and the proposed elevations for the ADU addition with material
.and finish details. It is unclear whether the project meets this standard. Please demonstrate
-compliance with this standard on the plans with formal application submittal.
b. Per CMC Section 21.10.050, the ADU shall not exceed a height of 35 feet and two stories if a
minimum roof pitch of 3:12 is provided or 24 feet and two stories if less than 3:12 roof pitch is
provided. It is unclear whether the project meets this standard. Plans submitted with a formal
application must provide height dimensions to demonstrate compliance with the height
regulations.
Pursuant to recent state laws, the total area of floor space for a detached accessory dwelling unit
shall not exceed 1,200 square feet. Based on the submitted plan, the existing habitable floor area
is 638 square feet and the addition of 336 square feet will result in a total of 974 square feet and
is under the 1,200 square feet maximum allowable floor area for a detached ADU. The proposed
project meets this standard.
c. Per CMC 21.10.110, lot coverage shall not exceed 40 percent of the lot. Lot coverage is defined
per CMC 21.04.061 as the total ground area of a site occupied by any building or structure as
measured from the outside of its surrounding external walls or supporting members. Building
coverage includes exterior structures such as stairs, arcades, bridges, permanent structural
elements protruding from buildings such as overhanging balconies, oriel windows, stories which
overhang a ground level story, garages, and covered carports. Excluded from building coverage
are roof eaves extending less than 30 inches from the face of any building, awnings, open parking
areas, and structures under 30 inches in height. It is unclear whether the project meets this
standard. Plans submitted with a formal application must provide a lot coverage calculation.
d. Pursuant to CMC Section 21.10.0S0(A){l)(c), the distance between buildings used for human
habitation and accessory buildings should be not less than ten feet for ADUs. Based on the
submitted plan, the existing conditions meet this requirement.
e. Per state laws, the minimum side and rear yard setback requirement for an ADU is four feet except
when an existing structure is converted to an ADU where existing setbacks are deemed
acceptable. Based on the submitted plans, with a 13-foot rear yard setback and a 10-foot street
side setback, the project meets setback requirements.
f. The proposed ADU must provide complete, independent living facilities and include permanent
provisions for living, eating, cooking, sanitation and sleeping. The plans shall show and label these
areas on the ADU floor plan as required.
g. An ADU shall not be rented for a period of less than 30 days and shall not be sold independently.
Plans submitted with a formal application must specify that the ADU shall not be rented for a
period of less than 30 days and shall not be sold independently.
PRE 2020-0040 (DEV2020·0323) -KELLETT ADU
January 26, 2021
Pa e 3
4. A formal development application submittal will need to include a completed Climate Action Plan
(CAP) Checklist (Form 8-50) to determine what requirements will apply to the project, to the
extent applicable for the proposed conversion of a garage to an ADU. CAP requirements are
related to energy efficiency, photovoltaic, electric vehicle charging, water heating and traffic
demand management requirements, as set forth in the California Green Building Standards Code
and in Carlsbad Municipal Code Chapters 18.21, 18.30 and 18.51 which is available on the city's
website at the following address:
http:ljwww.qcode.us/codes/car1sbad/view.php?topic=18&frames=on
All necessary application forms, submittal requirements, and fee information are available at the Planning
counter located in the Faraday Building at 1635 Faraday Avenue or online at
http://www.carlsbadca.gov/services/depts/planning/default.asp. You may also access the General Plan
Land Use Element and the Zoning Ordinance online at the website address shown; select Department
Listing; select Planning Home Page. Please review all information carefuliy before submitting.
Land Development Engineering:
1. Complete a Stormwater Standards Questionnaire. This questionnaire will guide you and the City in
determining what type of reports and storm water mitigation must be completed to satisfy state and
City storm water quality requirements. The questionnaire can be printed from the following website
link:
http://www.carlsbadca.gov/civicax/filebank/blobdload.aspx?BloblD-22711
Preliminary analysis suggests that the project is a Standard Project and subject to installing site design
and source control BMPs per Chapter 4 of the Carlsbad BMP Design Manual and per the Standard
Project Requirement Checklist (E36) that will also need to be completed. The link to the form is at:
http:ljwww.carlsbadca.gov/civicax/fi1ebank/blobdload.aspx?Blob1D-30141
2. A recent Preliminary Title Report (PTR) will be required with formal project application submittal.
3. All easements and encumbrances identified in the PTR must be indicated on the site plan.
If you would like to schedule a meeting to discuss this letter with the commenting departments, please
contact Jessica Bui at the number below. You may also contact each department individually as follows:
• Planning Division: Jessica Bui, Associate Planner, at (760) 602-4631
• Land Development Engineering: Allison Mclaughlin, Associate Engineer, at (760) 602-2732
DON NEU, AICP
City Planner
DN:JB:cf
c: Patrick Kellett, 4190 Sunnyhill Drive, Carlsbad, CA 92008
. Allison Mclaughlin, Project Engineer
HPRM/File Copy
Data Entry