Loading...
HomeMy WebLinkAbout2871 RANCHO CORTES; ; CB012751; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 09-19-2001 Retaining Wall Permit Permit No:CB012751 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: Building Inspection Request Line (760) 602-2725 2871 RANCHO CORTES CBAD RETAIN 2226602200 Lot#: 205 $2,520.00 Construction Type: NEW HACIENDAS-RETAIN WALL CITY SPECS -160 SF Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: ISSUED 08/21/2001 JM 09/19/2001 09/19/2001 Applicant: PACIFIC CREST COMMUNITIES \ STE345 £,., el) \..J Owner: CRV CARLSBAD L P C/O ALEX F ZIKAKIS 0347 09/19/01 0002 01 CGp 4141 INLAND EMPIRE BLVD !'~~x ,__,\o ONTARIO CA 91764 '"'J ~V 909 945-7800 ('\ f 9255 TOWNE CENTRE DR #520 SAN DIEGO CA 92121 Total Fees: $76.55 Total Payments To Date: $0.00 Balance Due: $76.55 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Strong Motion Fee Renewal Fee Add'I Renewal Fee Other Building Fee Additional Fees TOTAL PERMIT FEES Inspector: FINAL APPROVAL Date: ~ ~rd-z.____ Clearance: $45.79 $0.00 $29.76 $0.00 $1.00 $0.00 $0.00 $0.00 $0.00 $76.55 ------ NOTICE: Please take NOTICE that approval of your project includes the Mlmposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. 11 you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this proiect. NOR DOES IT APPLY to any fees/exactions of which vou have nreviouslv been niven a NOTICE similar to this or as to which the statute of limitations has nreviouslv otherwise exr. ired. 02 76.55 PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 1 . PROJECT INFORMATION FOR OFFICE USE ONLY PLAN CHECK NocBtL z.a,; I EST. VAL. ZSZiJ Plan Ck. Deposit --.-------,,--- Validated By__,....,_-'1--'-f'---A!ir-"\"--:. Date _________ __.._,__:...._-61-,'-" 2.S '1 I RAJ Lt:f:O Address (include Bldg/Suite #) Business Name (at this address) H-6,.<.r E;,-l!)A; ~ A-;1' M;r-J <:.-1::H> CA.flµ L~ M,j p6t..,. ( c, q3-0f Legal Description Subdivision Narr<e/Number Unit No. Phase No. Total # of units Assessor's Parcel # l-6:r::-fl' ~ I iJ lo WA Ll Description of Work Existing Use l t.o Proposed Use SO. FT. #of Stories # of Bedrooms # of Bathrooms 2. CONTACT PERSON (if dlfferen~rom applicant) 4 4 g.o~yg----Nl f tBlJ\ l}~&J: "'°' \:p<,,) -l _ I .l ,-)4',Ji\ E Mfr@£ Name Address City 3. APPLICANT e:{contractor TI Agent for Contractor O Owner O Agent for Owner State/Zip Telephone # Fax # P4<: I EK .. C~S-l::: C<IA..M.wJ,Ti'£:S .r"1l, 414l l.tJW~ Name Address City (! 61}'f45°-7BOcl ~,H(U[ J3L."a ~l4C orJ,; C4. State/Zip Telephone # 4. PROPERTY OWNER C,~,L G\ ILL; 13.+D • l-P 4' 41 .r l'h-, rJb tf,-tv\ R , u Name ii ACifress i}ulL> -/1-34,r-tJ~ti LA-q lll.4 ( 4' 05}q4£r 7B()o City State/Zip Telephone # 5. CONTRACTOR -COMPANY NAME (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a per it subjects the applicant to a civil penalty of not ~ol,e fhan five hundred dollars [$500)) N !) I -'-"lf'.>1-.>. ,s;: . . , I, Address City State/Zip Telephone #l 10'Y'f . 75bu State License # __ ,__'--,___,_....,.'-'----License Class __ ,.________ City Business License # _______ _ Designer Name Address City State/Zip Telephone State License # _________ _ 6. WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: ~ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. 0 I have and will maintain workers' compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: 1 Insurance Company C,\-L.rtJ l) t M Al [ ~ Policy No. N / 0 '1 Z.'{ 23 ,\: ITHIS SECTION NEED NOT BE COMPLETED IF; PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) Expiration Date 11/3 ,Jv I 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation laws of California. WARNING: Fail e to secure workers' sa 'on coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred ,000 • in ost of compensation, damages as provided for In Section 3706 of the La or code, interest and attorney's fees. SIGNATURE_pc::....,>L..:J...::cL--'-'-=~rl-----------------'"'.'::::'.- 7. OWNER- I hereby affirm that I am exempt from the Contractor's license law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): ______________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): ________________________________________________________ _ PROPERTY OWNER SIGNATURE _______________________ _ DATE _________ _ COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site 7 0 YES O NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8, CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civi'Ji.ode). LENDER'S NAME k,Ey3·ti·•··*= NATI lW½L ~';, .-l. LENDER'S ADDRESS 2..() l..'f L'-!J t=vA....y ,,~ t?r'h r, 1£0 , LA CA 'f DO'-7 9. APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit\.' of Carl~bad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST All LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit iss by the building Offici under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not menced within 180 d s tom the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is co for a p iod of O d s Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE DATE ~2...,/i-1...~,Y,l,-"Cl"--'/ ____ _ YELLOW: Applicant PINK: Finance Inspection List Permit#: CB012751 Date Inspection Item 01/02/2002 69 Final Masonry 12/27/2001 69 Final Masonry 12/06/2001 69 Final Masonry 09/27/2001 66 Grout 09/25/2001 66 Grout 09/21/2001 65 Retaining Walls 09/20/2001 61 Footing Type: RETAIN Inspector Act RB AP RB co RB co RB co GG AP RB AP GG NR HACIENDAS· RETAIN WALL CITY SPECS · 160 SF Comments 8FT 6IN WITH 5FT 9IN RETAINING· OK BY CITY ND CITY TO APPROVE HEIGHT SEE NOTICE· HEIGHT GREATER THAN ?FT 6IN HEIGHT GREATER THAN 5FT6IN Tuesday, May 28, 2002 Page 1 of 1 \ .._.,o<c CA,p. (~ ... ~ l' -0 U I ; '. -,, C' .,,.,. "ft/FQ9."" City of Carlsbad l:lfitillfEi·li:t•#i ■i·ll,1441111·1 BUILDING PLANCHECK CHECKLIST RETAINING WALL BUILDING PLANCHECK NUMBER: CB O('J t S-( BUILDING ADDRESS: k:-i 7 ( U"'ck, C..,~-') CT t't~ -c,<{ el~ L/f) Lo+ ;)-0,;;- PROJECT DESCRIPTION: ..cR.c.e::..:tc::a:.;..inc;.in"'"g'-W::..:.:::accll ______ _ ASSESSOR'S PARCEL NUMBER: ;Jcf;)-(_,,GO -;}-;)- ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore, any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failu comp! 1 h instructions in this report can pensi of ermit to build. Date:tP~ ATTACHMENTS Right-of-Way Permit Application DENIAL Please see the attached report of deficiencies marked with Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: By: Date: a/rzSC ~x) / _________ Date: _________ Date: ENGINEERING DEPT. CONTACT PERSON NAME: Casey R. Arndt City of Carlsbad ADDRESS: 1635 Faraday Ave Carlsbad, CA 92008 PHONE: (760) 602-2775 H.\D.,./elopmen1 Setv1ci»IMASTEAS\CHECKLISTSIBwld1~g Plancheck Ckl,s1 Form -RETAINING WAL.LS doc Rev 612&'98 1635 Faraday Avenue• Carlsbad, CA 92008-7314 • (760) 602-2720 • FAX (760) 602-8562 @ < BUILDING PLANCHECK CHECKLIST RETAINING WALLS ~No✓• 3AD✓ 0 . 1. Provide a fully dimensioned site plan drawn to scale. Show: ~,/ v-,M.S¾'" . / sements .!s \-{ \'<<;---~;-,,,,,-~orth Arrow S 1,, \'r (.,J,ll<,; ~'-' & \. v) A,.\ l "j3': Existing & Proposed Structures (,C.""' -\<-" ~(t1.~<-lr"' · . ,,f,),,ir _ __,,.(dimensioned from street) taining Wall cation and height) ~r,v< ~~ ·\--> ~\ u ~-Property Lines \ l1£..-~ .--'-:, I ylNA"o" O O 2. Sh/n site plan: 0 0 0 0 0 0 0 4~ainage Patterns ~~ting & Proposed Slopes Y.Existing Topography 3. Include on title sheet: /2te Address ~sessor's Parcel Number ~ Legal Description D. Grading Quantities Cut___ Fill ___ Import/Export __ _ (Grading Permit and Haul Route Permit may be required) 4. Project does not comply with the following Engineering Conditions of approval for Project No. _________________ _ Conditions were complied with by: _______ Date: ____ _ MISCELLANEOUS PERMITS 5. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. A separate Right-of-Way issued by the Engineering Department is required for the following: Please obtain an application for Right-of-Way permit from the Engineering Department. Page 1 H:\Oe~e(opmen1 Sffi•cN\MASTEAS\CHECKLISTS\Building f'lanchock Cklis! Form ·RETAINING WALLS.doc Rev. &2619B PLANNINC/ENCINEERINC APPROVALS .I PERMIT NUMBER CB O 12 7 s I DATE______,,.34--/J_9_,__/0_____._/ __ ADDRESS 'l ~ l / R o(\Gh o Co c-f-c. S RESIDENTIAL ADDITION MINOR < < $10,000.00) OTHER \{(, t-\,A, Jo l ( PLANNER Vo A{) ~ ~Q ENGINEER -------- oocs/Misforms/Plannlng Engineering Approvals TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING DATE ' City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 12-03-2001 Plan Check Revision Permit No:PCR01283 Building Inspection Request Line (760) 602-2725 Job Address: 2871 RANCHO CORTES CBAD Permit Type: Parcel No: Valuation: Reference #: PCR 2226602200 $0.00 CB012751 Lot#: 205 Construction Type: NEW Status: Applied: Entered By: Plan Approved: Issued: ISSUED 11/06/2001 JM 11/19/2001 12/03/2001 Project Title: HACIENDAS -RANCHO CARRILLO Inspect Area: ADD 65 SF OF FREESTANDING WALL ON TOP RETAIN WALL 5697 12/03/01 0002 01 Applicant: PACIFIC CREST COMMUNITIES STE 345 4141 INLAND EMPIRE BLVD ONTARIO CA 91764 909 945-7800 Owner: CRV CARLSBAD L P C/O ALEX F ZIKAKIS 9255 TOWNE CENTRE DR #520 SAN DIEGO CA 92121 CGP Total Fees: $120.00 Total Payments To Date: $0.00 Balance Due: $120.00 Plan Check Revision Fee Additional Fees Inspector: _____ _ FINAL APPROVAL Date: $120.00 $0.00 Clearance: _____ _ NOTICE: Please take NOTICE that approval of your project includes the ~Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as '1ees/exactions: You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any tees/exactions of which •1ou have nreviouslv been aiven a NOTICE similar to this or as to which the statute of limitations has nreviouslv otherwise exnired. 02 120-00 ' FOR OFFICE USE ONLY f'-ERMIT APPLICATION PLAN CHECK No./t';fd/4:f3 CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 EST. VAL. __________ _ Plan Ck. Deposif-;::; Validated By_V~ 14..__~ __ ....,.___,,.........,.._ Date ________ __,___._,_,...c...,<--=~-- 1. .PROJECT INFORMATION 2871 Rancho Cortes Haciendas at Rancho Carrillo • Buw,ess Name (at this add~ss) Haciendas at Kancho ~arriL~o Model 1 Le~I DJlSCription 22L-t>60-22 Lot No. Subdivision Name/Number Unit No. Phase No. SFR Total # of units $FR ip o f or fl...R.-+. llfjyt. ,J,-, /JrYlsa. :T, 2. CONTACT PERSON (If different trb a;li:,;;;;; '--'U.' Carol Long, Project Manager (909) 945-7800, Ext. 231 Fax 909-945-7807 Name Address City State/Zip Telephone# Fax# 3. APPLICANT O Contractor CJ Agent for Contractor p Owner O Agent for Owner Pacific Crest Communities, Inc., 414 InlanaEmpire Blvd., Suite 345, Ontario, CA 91764 Name Address City State/Zip Telephone# 909-945-7800 CRVP~f!f1b'?i~~E\P, 4141 Inland Empire Blvd., /1345, Ontario, CA 91764 909-945-7800 Name Address City State/Zip Telephone# 6. CONTRACTOR • COMPANY NAME (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031 .5 by any applicant for a eermit sul?,jects the applicant to a civil ~~nalt)r'. of not more than five hunqr~d d9IlarsJl500Jl, 8 Pacific Crest Communities, Inc. 4141 inland Empire Blvd., 1F34), Ontario, CA ~1704 ~U9-~45-7 00 Address City State/Zip Telephone# Name 777481 State License # _________ _ B License Class _________ _ City Business License # _______ _ Designer Name Address City State/Zip Telephone State License # _________ _ 6. WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Cal Indemnity Policy No. N 106 29 53A Expiration Date 12/31/01 (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100) OR LESS) 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Wo s' Compensation Laws of California. WARNING: Fail ,,,.-,,,., ...... "-pensation coverage is unlawful, and shall subject an employer to criminal pen he cost of compensation, damages as provided for in Section 3706 of the ~ft • ....-c, ...... SIGNATURE _ _,,""""''c--c.,1---'--+-'r---------------------DATE __ '-f-__ __,,_._c.+--- 7. OWNER-BUILDER DECLARA Tl e Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). O I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES D NO 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4 . I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): ______________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): ________________________________________________________ _ PROPERTY OWNER SIGNATURE _______________________ _ DATE _________ _ COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES O NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR )S MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 30971i) Civil Code). LENDER'SNAME KeyBank National Assn LENDER'SADDRESS 2029 Century Park E, #950, LA, CA 90067 9. .APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit'1 of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WH)CH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued the build' Otticial under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is nol c 80 y the date of such permit or if lhe building or work authorized by su pe t is suspended or abandoned at any time after the work is com f ys (Section 106.4.4 Uniform Building Code). / / APPLICANT'S SIGNATURE ---._..c--r----"'t"-~-----------------DATE .,_/-' j{:.....+_..c-+.=...L.. ______ _ YELLOW: Applicant PINK: Finance EsGil Corporation 1n Partnusliip Witli ljovemment for 'lJuiUing Safety DATE: 11/15/01 JURISDICTION: Carlsbad PLAN CHECK NO.: 01-2751 rev(PCR0l-283) PROJECT ADDRESS: 2871 Rancho Cortes PROJECT NAME: Retaining Wall SET: I ~NT □ PLAN REVIEWER □ FILE C8:J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: C8:J Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant tha_t the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax#: Mail Telephone Fax In Person 0 REMARKS: By: David Yao Enclosures: original approved plan Esgil Corporation 0 GA O MB O EJ O PC 11/8 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 ·-· --···------·------------ Carlsbad 01-2751 rev(PCR0l-283) 11/15/01 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad rev(PCR0 1-283) PLAN CHECK NO.: 01-2751 PREPARED BY: David Yao DATE: 11/15/01 BUILDING ADDRESS: 2871 Rancho Cortes BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. retainina wall Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bid . Permit Fee b Ordinance ... g y -----'-------------'--~ Plan Check Fee by Ordinance Type of Review: □ Complete Review D Structural Only D Repetitive Fee 3 Repeats * Based on hourly rate Comments: D Other D Hourly 1 I Hour* Esgll Plan Review Fee ($) $120.001 $96.001 Sheet 1 of 1 macvalue.doc ---• ,,,••~··-------~-- PLANNINC/ENCINEERINC APPROVALS PERMIT NUMBER CB t> c. 12-0 /. ~ 2 8 3 ~ RESIDENTIAL ADDITION MINOR ( < $10,000.00) . . PLANNER V-o/A10:'> ENCIN&R/~ /)[J]tj/( DoCSJMlSforms/PlanninQ Engineering Approvals DATE //-/1/~0 / TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLACE FAIRE COMPLETE OFFICE BUILDING DATE / {-( l(-0 / DATE // ~ Je-0/ __ ....:;___..;.__ __ c0"d %S5 0s:0, ,00c-9c-1J□ Geotechnical • Geologic• Environmental 5741 Palmer Way • Carlsbad, California 92008 • (760) 438-3155 • FAX (760) 931-0915 January 16, 2001 Revised March 28, 2001 Pacific Crest CommunlUea, Inc. 4141 Inland Empire Boulevard, Suite 345 Ontario, California 91764 Attention: Ms.carollong W.O. 2937-C-SC Subject: Foundation Design Parameters, Carlsbad Tract 93-04, Model Lots 205 through 208, Rancho Carrillo, Carlsbad, San Diego County, California Dear Ms. Long: In accordance with your request, GeoSolls, Inc. (GSI) is pleased to submit this report for foundation design parameters regarding the proposed construction. This report is based on a limited site reconnaissance, as well as the Geocon (2000) final report on the project (see the Appendix). FAULTING AND REGIONAL SEISMICITY The seismic shaking parameters provided In the final report by Geocon (2000) are applicable with the exception that our fault search showed that the average distance to Rose Canyon fault is approximately 8 miles (13 kilometers). FOUNDATION RECOMMENDATIONS Poat-Tensioned Foundation Design General The information and recommendations presented In this section are not meant to supersede design by a registered structural engineer or clvll engineer famlllar with post- tensioned slab design or corrosion engineering consultant. Upon request, GSI could provide additfonal data/consultation regarding soil parameters as related to post-tensioned slab design. Post-tensioned slabs should be designed in accordance with the Post- Tensioning Institute (PTQ Method. Alternatives to the PTI method may be used If ! "ONI 's7IOS030 =A8 1N3S ~ 30Vd E0"d 1/.S5 APPENDIX REFERENCES rn0c:-9c:-1Jo /3 Geocon Incorporated, 2000, Final report of testing and observation services during grading, VIiiages R-3 and Q-4. Lots 166 through 238, Rancho Carrillo, Carlsbad, California, dated April. ~:----:-:--:-:~--::--=-~~-.,--::c·-::-:-----:----_,1 __. 1996a, Ran Carrillo, Villages F, G and L through R, Carlsbad, California, human health risk assessment, project no. 08053-06-06, dated revised October 4. __ , 1996b, Rancho Carrillo, Villages F, G and L through R, Carlsbad, California, phase I environmental site assessment, project no. 08053-06-05, dated August 7 . • 1993, Rancho Carrillo, VIiiages N, 0, a. R, T, and U, Carlsbad, California, --preliminary geotechnical investigation, project no. 04354-12-03, dated February 16. GeoSolls, Inc., 2000, Due dlllgence review, Carlsbad Tract 93-04, Phases 4 and 5, Lots 166 through 210 and Lots 214 through 238, City of Carlsbad, San Diego County, California, W.O. 2937-A-SC, dated September 21. Hart, E.W. and Bryant W.A., 1997, Fault rupture hazard zones in California, Alquist-Priolo earthquake fault zoning act with index to earthquake fault zone maps, California Division of Mines and Geology, Special Publication 42, undated. Jennings, C.W., 1994, Preliminary fault activity map of California and vicinity with locations and ages of volcanic eruptions , scale 1 :750,000, CDMG map series, Map No. 6. Rick Engineering Company, 2000, Improvement Plans for: Rancho Carrillo, Phases 3, 4 & 5, C.T. 93-04, J.N. 12972, revised February 8. , 1999, Grading and Erosion control Plans for. Rancho Carrillo, Phases 3, 4 & 5, C.T. --93-04, J.N.12972, revised June 7. 9/~ 3~'\'d a.DSoils, Inc. '.Sf60f~609L '.·oNI 'S7IOS03~ 'A8 lN3S I I I ~ ) r' I 1i 1"0"d %S6 9/t 30\fd S,60,.:609l. 0s,0,: ,:00c-9c-LJ□ tt- FINAL REPORT OF TESTING AND OBSERVATION SERVICES DURING SITE GRADING VILLAGES R-3 and Q-4 LOTS 166 THROUGH 238 RANCHO CARRILLO CARLSBAD, CALIFORNIA PREPARED FOR CONTINENT AL RESIDENTIAL. CARLSBAD, CALIFORNIA APRIL 2000 ! S 160 !~609l !"ONI 'S7IOS030 =AS LN3S S0"d Y.S5 S1501E509<. 0s:0, ,00c-9c-1Jo 5.0 Seismic: Design Parameters 5.1 The following table summarizell site design criteria obtained from the 1997 Uniform Building Code (UBC). The values listed in Table 5.1 are for the Rose Canyon Fault which is identified as a Type B fault and is more dominant than the nearest type A fault due to its close proximity to the site. The Rose Canyon Fault is located approximately 13 miles southwest of the site. TABLE 5.1 SITE DESIGN CRITERIA Parameter Value UBC Reference Seiamie Zone FaclDr 0.40 Table 16-1 Soil Profile Sn Table 11>-J Seismic Coefficient, c.. 0.44 Table 16-Q Scinnic Coefficient, C. 0.64 Table 16-R Near-Source FIClor, Na 1.0 Table 16-S N--Soun:e FIClor, N. 1.0 ' Table 16-T Seismic Source B Table 16-U 6.0 Retaining Walls and Lateral Loads 6.1 Retaining walls not teStrained at the llop and having a level backfill surface should be . designed for an active soil pressure equivalent to the pressure exerted by a fluid density of 30 pounds per cubic foot (pcf). Where the backfill will be inclined at no steeper thau 2.0 to 1.0, an active soil pressure of 40 pcf is reconnnendcd. These soil pressures assume that the backfill materials within an area bounded by the wall and a 1:1 plane extending upward from the base of the wall possess an Expansion Index of less than 50. For those lots with finish grade soils having an Expansion Index greater than 50 and/or where backfill materials do .not confonn to the above criteria, Geocon Incorpora!Ed should be consulted for additional nocommendations. 6.2 Unrestrained walls arc those that arc allowed to rotate more than 0.001H at the top of the wall. Where walls arc restrained from movement at the top, an additional uniform pressure of 7H psf (where H equals the height of the retaining wall portion of the wall in feet) should be added to the above active soil pressure 6.3 All retaining walls should be provided with a drainage system adequate to prevent the buildup of hydrostatic fon:es and should be waterproofed as required by the project Project No. 05845-12-43 -10 -April 2.6, 2000 9/S 30'i'd !s(60(e6oeL !·oNI 'S7IOS030 =AS 1N3S ] I J 7 1 l ·\ .. I I ·I n J I l 90'd ' ' 6.4 6.5 6.6 SJ:607:(6091.. 0S:01 architect The use of drainage openings through the base of the wall (weep holes, etc.) is not recommended where the seepage could be a nuisance or otherwise adversely impact che propcny adjacent to the base of the wall. A typical retaining wall drain system is ~sented on Figure 4. The above recommendations assume a properly compacted granular (Expansion Index less than SO) ba.ckfill material with no hydrostatic forces or imposed sun:harg,: loa.cl. If conditions different tban tho:;e described are anticipated, or if specific drainage details arc desired, Geocon Incorporated should be contleted for additional recommendations. In generu, wall founda.tioru; having a minimum dq,th and width of one foot 11111y be designed fur an allCWiable soil bearing pressure of 2,000 paf, provided the soil with.in 3 feet below lhe base of the wall 1w an Expansion Index of less than 90. The proximity of the > foUDdal:ion to the top of a slope steeper than 3: I could impact the allowable soil bearing pressure. Tli='cfim:, Geooon Jncorpon.ted should be consulted where such a condition is anticipated. F.;,. resistance to lateral loads, an allowable ~ive earth pressure equivalent t.o a fluid density of JOO pcf is rccomnmded for footings or shear keys poured neat against properly compacted granular fill soils or undisturl,ed natural soils. The allowable passive press= ass11D1es a horizontal surface extending at leaat 5 feet or ~ times the surface generating the passive prcsaurc, whichever is greater. The upper 12 inches of material not protected by floor slabs or pavement should not be included in the design for lateral resistance. An allowable friction coefficient of 0.4 may be used for resistance lo sliding between sci! and concrete. Thia friction coefficient may be combined with the allowable passive earth pressure when delc:nnining resistance lo lateral loads. The recommendations presented above are generally applicable to the design of rigid concrete or masonry retaining walls having a maximum height of 8 feet. In the event that walls higher than 8 feet or other types of walls are planned, such as cril>-type walls, Geocoo fncorporatdd should be consulted for additional recommendations. 7.0 Slope Maintenance 7.1 Slopes that arc steeper than 3: I (horizontal:vertical) may, under conditions which arc beth difficult to prevent and predict, be susceptfblc to near !!Uliilce (surficial) slope instability. The instability is typically limited to the outer three feet of a portion of the slope and usually does not directly impact the improvements on the pad areas above or below the slope. The occum:nce of Sllificial insmbility is more prevalent on fill slopes and is generally preceded by a period of heavy rainfall, excessive imgation, or the migration of Projoct No. 0S845-l2-<13 -11 -April 26, 2000 ~-ONI 'S7IOS03D 'A8 lN3S 9/9 3DVd ~~vrs:or ro·9~·100 ----------··--·· ··-···~-·