HomeMy WebLinkAbout2871 RANCHO CORTES; ; CB012751; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
09-19-2001 Retaining Wall Permit Permit No:CB012751
Job Address:
Permit Type:
Parcel No:
Valuation:
Reference #:
Project Title:
Building Inspection Request Line (760) 602-2725
2871 RANCHO CORTES CBAD
RETAIN
2226602200 Lot#: 205
$2,520.00 Construction Type: NEW
HACIENDAS-RETAIN WALL
CITY SPECS -160 SF
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
ISSUED
08/21/2001
JM
09/19/2001
09/19/2001
Applicant:
PACIFIC CREST COMMUNITIES \
STE345 £,., el) \..J
Owner:
CRV CARLSBAD L P
C/O ALEX F ZIKAKIS
0347 09/19/01 0002 01
CGp
4141 INLAND EMPIRE BLVD !'~~x ,__,\o
ONTARIO CA 91764 '"'J ~V
909 945-7800 ('\ f
9255 TOWNE CENTRE DR #520
SAN DIEGO CA 92121
Total Fees: $76.55 Total Payments To Date: $0.00 Balance Due: $76.55
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Strong Motion Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Additional Fees
TOTAL PERMIT FEES
Inspector:
FINAL APPROVAL
Date: ~ ~rd-z.____ Clearance:
$45.79
$0.00
$29.76
$0.00
$1.00
$0.00
$0.00
$0.00
$0.00
$76.55
------
NOTICE: Please take NOTICE that approval of your project includes the Mlmposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. 11 you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this proiect. NOR DOES IT APPLY to any
fees/exactions of which vou have nreviouslv been niven a NOTICE similar to this or as to which the statute of limitations has nreviouslv otherwise exr. ired.
02
76.55
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
1 . PROJECT INFORMATION
FOR OFFICE USE ONLY
PLAN CHECK NocBtL z.a,; I
EST. VAL. ZSZiJ
Plan Ck. Deposit --.-------,,---
Validated By__,....,_-'1--'-f'---A!ir-"\"--:.
Date _________ __.._,__:...._-61-,'-"
2.S '1 I RAJ Lt:f:O
Address (include Bldg/Suite #) Business Name (at this address)
H-6,.<.r E;,-l!)A; ~ A-;1' M;r-J <:.-1::H> CA.flµ L~ M,j p6t..,. ( c, q3-0f
Legal Description Subdivision Narr<e/Number Unit No. Phase No. Total # of units
Assessor's Parcel #
l-6:r::-fl' ~ I iJ lo WA Ll
Description of Work
Existing Use
l t.o
Proposed Use
SO. FT. #of Stories # of Bedrooms # of Bathrooms
2. CONTACT PERSON (if dlfferen~rom applicant) 4 4 g.o~yg----Nl f tBlJ\ l}~&J: "'°' \:p<,,) -l _ I .l ,-)4',Ji\ E Mfr@£
Name Address City
3. APPLICANT e:{contractor TI Agent for Contractor O Owner O Agent for Owner
State/Zip Telephone # Fax #
P4<: I EK .. C~S-l::: C<IA..M.wJ,Ti'£:S .r"1l, 414l l.tJW~
Name Address City
(! 61}'f45°-7BOcl
~,H(U[ J3L."a ~l4C orJ,; C4.
State/Zip Telephone #
4. PROPERTY OWNER
C,~,L G\ ILL; 13.+D • l-P 4' 41 .r l'h-, rJb tf,-tv\ R , u
Name ii ACifress
i}ulL> -/1-34,r-tJ~ti LA-q lll.4 ( 4' 05}q4£r 7B()o
City State/Zip Telephone #
5. CONTRACTOR -COMPANY NAME
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a per it subjects the applicant to a civil penalty of not ~ol,e fhan five hundred dollars [$500)) N !) I -'-"lf'.>1-.>. ,s;: . . , I,
Address City State/Zip Telephone #l 10'Y'f . 75bu
State License # __ ,__'--,___,_....,.'-'----License Class __ ,.________ City Business License # _______ _
Designer Name Address City State/Zip Telephone
State License # _________ _
6. WORKERS' COMPENSATION
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
~ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the labor Code, for the performance
of the work for which this permit is issued.
0 I have and will maintain workers' compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are: 1
Insurance Company C,\-L.rtJ l) t M Al [ ~ Policy No. N / 0 '1 Z.'{ 23 ,\:
ITHIS SECTION NEED NOT BE COMPLETED IF; PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS)
Expiration Date 11/3 ,Jv I
0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation laws of California.
WARNING: Fail e to secure workers' sa 'on coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
,000 • in ost of compensation, damages as provided for In Section 3706 of the La or code, interest and attorney's fees.
SIGNATURE_pc::....,>L..:J...::cL--'-'-=~rl-----------------'"'.'::::'.-
7. OWNER-
I hereby affirm that I am exempt from the Contractor's license law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0 I am exempt under Section ______ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO
2. I (have/ have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number/ contractors license number): ______________________________________________ _
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work): ________________________________________________________ _
PROPERTY OWNER SIGNATURE _______________________ _ DATE _________ _
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES O NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site 7 0 YES O NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
8, CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civi'Ji.ode).
LENDER'S NAME k,Ey3·ti·•··*= NATI lW½L ~';, .-l. LENDER'S ADDRESS 2..() l..'f L'-!J t=vA....y ,,~ t?r'h r, 1£0 , LA CA 'f DO'-7
9. APPLICANT CERTIFICATION
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit\.' of Carl~bad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST All LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit iss by the building Offici under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not menced within 180 d s tom the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is co for a p iod of O d s Section 106.4.4 Uniform Building Code).
APPLICANT'S SIGNATURE DATE ~2...,/i-1...~,Y,l,-"Cl"--'/ ____ _
YELLOW: Applicant PINK: Finance
Inspection List
Permit#: CB012751
Date Inspection Item
01/02/2002 69 Final Masonry
12/27/2001 69 Final Masonry
12/06/2001 69 Final Masonry
09/27/2001 66 Grout
09/25/2001 66 Grout
09/21/2001 65 Retaining Walls
09/20/2001 61 Footing
Type: RETAIN
Inspector Act
RB AP
RB co
RB co
RB co
GG AP
RB AP
GG NR
HACIENDAS· RETAIN WALL
CITY SPECS · 160 SF
Comments
8FT 6IN WITH 5FT 9IN RETAINING· OK
BY CITY
ND CITY TO APPROVE HEIGHT
SEE NOTICE· HEIGHT GREATER THAN
?FT 6IN
HEIGHT GREATER THAN 5FT6IN
Tuesday, May 28, 2002 Page 1 of 1
\
.._.,o<c CA,p. (~
... ~ l' -0 U I ;
'. -,,
C' .,,.,.
"ft/FQ9.""
City of Carlsbad
l:lfitillfEi·li:t•#i ■i·ll,1441111·1
BUILDING PLANCHECK CHECKLIST
RETAINING WALL
BUILDING PLANCHECK NUMBER: CB O('J t S-(
BUILDING ADDRESS: k:-i 7 ( U"'ck, C..,~-')
CT t't~ -c,<{ el~ L/f) Lo+ ;)-0,;;-
PROJECT DESCRIPTION: ..cR.c.e::..:tc::a:.;..inc;.in"'"g'-W::..:.:::accll ______ _
ASSESSOR'S PARCEL NUMBER: ;Jcf;)-(_,,GO -;}-;)-
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans, information
and/or specifications provided in your submittal;
therefore, any changes to these items after this date,
including field modifications, must be reviewed by this
office to insure continued conformance with applicable
codes. Please review carefully all comments attached,
as failu comp! 1 h instructions in this report can
pensi of ermit to build.
Date:tP~
ATTACHMENTS
Right-of-Way Permit Application
DENIAL
Please see the attached report of deficiencies
marked with Make necessary corrections to
plans or specifications for compliance with
applicable codes and standards. Submit corrected
plans and/or specifications to this office for review.
By:
By:
Date: a/rzSC ~x) /
_________ Date:
_________ Date:
ENGINEERING DEPT. CONTACT PERSON
NAME: Casey R. Arndt
City of Carlsbad
ADDRESS: 1635 Faraday Ave
Carlsbad, CA 92008
PHONE: (760) 602-2775
H.\D.,./elopmen1 Setv1ci»IMASTEAS\CHECKLISTSIBwld1~g Plancheck Ckl,s1 Form -RETAINING WAL.LS doc Rev 612&'98
1635 Faraday Avenue• Carlsbad, CA 92008-7314 • (760) 602-2720 • FAX (760) 602-8562 @
<
BUILDING PLANCHECK CHECKLIST
RETAINING WALLS
~No✓• 3AD✓
0 . 1. Provide a fully dimensioned site plan drawn to scale. Show:
~,/ v-,M.S¾'" . / sements .!s \-{ \'<<;---~;-,,,,,-~orth Arrow
S 1,, \'r (.,J,ll<,; ~'-' & \. v) A,.\ l "j3': Existing & Proposed Structures (,C.""' -\<-" ~(t1.~<-lr"' · . ,,f,),,ir _ __,,.(dimensioned from street)
taining Wall
cation and height)
~r,v< ~~ ·\--> ~\ u ~-Property Lines
\ l1£..-~ .--'-:, I ylNA"o"
O O 2. Sh/n site plan:
0
0 0 0
0 0 0
4~ainage Patterns
~~ting & Proposed Slopes
Y.Existing Topography
3. Include on title sheet:
/2te Address
~sessor's Parcel Number
~ Legal Description
D. Grading Quantities Cut___ Fill ___ Import/Export __ _
(Grading Permit and Haul Route Permit may be required)
4. Project does not comply with the following Engineering Conditions of approval
for Project No. _________________ _
Conditions were complied with by: _______ Date: ____ _
MISCELLANEOUS PERMITS
5. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way.
A separate Right-of-Way issued by the Engineering Department is required
for the following:
Please obtain an application for Right-of-Way permit from the Engineering
Department.
Page 1
H:\Oe~e(opmen1 Sffi•cN\MASTEAS\CHECKLISTS\Building f'lanchock Cklis! Form ·RETAINING WALLS.doc Rev. &2619B
PLANNINC/ENCINEERINC APPROVALS
.I
PERMIT NUMBER CB O 12 7 s I DATE______,,.34--/J_9_,__/0_____._/ __
ADDRESS 'l ~ l / R o(\Gh o Co c-f-c. S
RESIDENTIAL ADDITION MINOR
< < $10,000.00)
OTHER \{(, t-\,A, Jo l (
PLANNER Vo A{) ~
~Q
ENGINEER --------
oocs/Misforms/Plannlng Engineering Approvals
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
DATE
' City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
12-03-2001 Plan Check Revision Permit No:PCR01283
Building Inspection Request Line (760) 602-2725
Job Address: 2871 RANCHO CORTES CBAD
Permit Type:
Parcel No:
Valuation:
Reference #:
PCR
2226602200
$0.00
CB012751
Lot#: 205
Construction Type: NEW
Status:
Applied:
Entered By:
Plan Approved:
Issued:
ISSUED
11/06/2001
JM
11/19/2001
12/03/2001
Project Title: HACIENDAS -RANCHO CARRILLO Inspect Area:
ADD 65 SF OF FREESTANDING WALL ON TOP RETAIN WALL 5697 12/03/01 0002 01
Applicant:
PACIFIC CREST COMMUNITIES
STE 345
4141 INLAND EMPIRE BLVD
ONTARIO CA 91764
909 945-7800
Owner:
CRV CARLSBAD L P
C/O ALEX F ZIKAKIS
9255 TOWNE CENTRE DR #520
SAN DIEGO CA 92121
CGP
Total Fees: $120.00 Total Payments To Date: $0.00 Balance Due: $120.00
Plan Check Revision Fee
Additional Fees
Inspector: _____ _
FINAL APPROVAL
Date:
$120.00
$0.00
Clearance: _____ _
NOTICE: Please take NOTICE that approval of your project includes the ~Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as '1ees/exactions: You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
tees/exactions of which •1ou have nreviouslv been aiven a NOTICE similar to this or as to which the statute of limitations has nreviouslv otherwise exnired.
02
120-00
' FOR OFFICE USE ONLY
f'-ERMIT APPLICATION PLAN CHECK No./t';fd/4:f3
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
EST. VAL. __________ _
Plan Ck. Deposif-;::;
Validated By_V~ 14..__~ __ ....,.___,,.........,.._
Date ________ __,___._,_,...c...,<--=~--
1. .PROJECT INFORMATION 2871 Rancho Cortes Haciendas at Rancho Carrillo
• Buw,ess Name (at this add~ss) Haciendas at Kancho ~arriL~o Model 1
Le~I DJlSCription 22L-t>60-22 Lot No. Subdivision Name/Number Unit No. Phase No. SFR Total # of units $FR
ip o f or fl...R.-+. llfjyt. ,J,-, /JrYlsa. :T,
2. CONTACT PERSON (If different trb a;li:,;;;;; '--'U.'
Carol Long, Project Manager (909) 945-7800, Ext. 231 Fax 909-945-7807
Name Address City State/Zip Telephone# Fax#
3. APPLICANT O Contractor CJ Agent for Contractor p Owner O Agent for Owner Pacific Crest Communities, Inc., 414 InlanaEmpire Blvd., Suite 345, Ontario, CA 91764
Name Address City State/Zip Telephone# 909-945-7800
CRVP~f!f1b'?i~~E\P, 4141 Inland Empire Blvd., /1345, Ontario, CA 91764 909-945-7800
Name Address City State/Zip Telephone#
6. CONTRACTOR • COMPANY NAME
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031 .5 by any applicant for a eermit sul?,jects the applicant to a civil ~~nalt)r'. of not more than five hunqr~d d9IlarsJl500Jl, 8 Pacific Crest Communities, Inc. 4141 inland Empire Blvd., 1F34), Ontario, CA ~1704 ~U9-~45-7 00
Address City State/Zip Telephone# Name 777481
State License # _________ _ B License Class _________ _ City Business License # _______ _
Designer Name Address City State/Zip Telephone
State License # _________ _
6. WORKERS' COMPENSATION
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are:
Insurance Company Cal Indemnity Policy No. N 106 29 53A Expiration Date 12/31/01
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100) OR LESS)
0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Wo s' Compensation Laws of California.
WARNING: Fail ,,,.-,,,., ...... "-pensation coverage is unlawful, and shall subject an employer to criminal pen
he cost of compensation, damages as provided for in Section 3706 of the ~ft • ....-c, ......
SIGNATURE _ _,,""""''c--c.,1---'--+-'r---------------------DATE __ '-f-__ __,,_._c.+---
7. OWNER-BUILDER DECLARA Tl
e Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
O I am exempt under Section ______ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES D NO
2. I (have/ have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4 . I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number): ______________________________________________ _
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): ________________________________________________________ _
PROPERTY OWNER SIGNATURE _______________________ _ DATE _________ _
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES D NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES O NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR )S MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
8. CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 30971i) Civil Code).
LENDER'SNAME KeyBank National Assn LENDER'SADDRESS 2029 Century Park E, #950, LA, CA 90067
9. .APPLICANT CERTIFICATION
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit'1 of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WH)CH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued the build' Otticial under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is nol c 80 y the date of such permit or if lhe building or work authorized by su pe t is suspended or abandoned
at any time after the work is com f ys (Section 106.4.4 Uniform Building Code). / /
APPLICANT'S SIGNATURE ---._..c--r----"'t"-~-----------------DATE .,_/-' j{:.....+_..c-+.=...L.. ______ _
YELLOW: Applicant PINK: Finance
EsGil Corporation
1n Partnusliip Witli ljovemment for 'lJuiUing Safety
DATE: 11/15/01
JURISDICTION: Carlsbad
PLAN CHECK NO.: 01-2751 rev(PCR0l-283)
PROJECT ADDRESS: 2871 Rancho Cortes
PROJECT NAME: Retaining Wall
SET: I
~NT
□ PLAN REVIEWER
□ FILE
C8:J The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
C8:J Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant tha_t the plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by: ) Fax#:
Mail Telephone Fax In Person
0 REMARKS:
By: David Yao Enclosures: original approved plan
Esgil Corporation
0 GA O MB O EJ O PC 11/8 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
·-· --···------·------------
Carlsbad 01-2751 rev(PCR0l-283)
11/15/01
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
rev(PCR0 1-283)
PLAN CHECK NO.: 01-2751
PREPARED BY: David Yao DATE: 11/15/01
BUILDING ADDRESS: 2871 Rancho Cortes
BUILDING OCCUPANCY: TYPE OF CONSTRUCTION:
BUILDING AREA Valuation Reg. VALUE
PORTION ( Sq. Ft.) Multiplier Mod.
retainina wall
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
Bid . Permit Fee b Ordinance ... g y -----'-------------'--~
Plan Check Fee by Ordinance
Type of Review: □ Complete Review D Structural Only
D Repetitive Fee 3 Repeats
* Based on hourly rate
Comments:
D Other
D Hourly 1 I Hour*
Esgll Plan Review Fee
($)
$120.001
$96.001
Sheet 1 of 1
macvalue.doc
---• ,,,••~··-------~--
PLANNINC/ENCINEERINC APPROVALS
PERMIT NUMBER CB t> c. 12-0 /. ~ 2 8 3
~
RESIDENTIAL ADDITION MINOR
( < $10,000.00)
. .
PLANNER V-o/A10:'>
ENCIN&R/~ /)[J]tj/(
DoCSJMlSforms/PlanninQ Engineering Approvals
DATE //-/1/~0 /
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLACE FAIRE
COMPLETE OFFICE BUILDING
DATE / {-( l(-0 /
DATE // ~ Je-0/ __ ....:;___..;.__ __
c0"d %S5 0s:0, ,00c-9c-1J□
Geotechnical • Geologic• Environmental
5741 Palmer Way • Carlsbad, California 92008 • (760) 438-3155 • FAX (760) 931-0915
January 16, 2001
Revised March 28, 2001
Pacific Crest CommunlUea, Inc.
4141 Inland Empire Boulevard, Suite 345
Ontario, California 91764
Attention: Ms.carollong
W.O. 2937-C-SC
Subject: Foundation Design Parameters, Carlsbad Tract 93-04, Model Lots 205
through 208, Rancho Carrillo, Carlsbad, San Diego County, California
Dear Ms. Long:
In accordance with your request, GeoSolls, Inc. (GSI) is pleased to submit this report for
foundation design parameters regarding the proposed construction. This report is based
on a limited site reconnaissance, as well as the Geocon (2000) final report on the project
(see the Appendix).
FAULTING AND REGIONAL SEISMICITY
The seismic shaking parameters provided In the final report by Geocon (2000) are
applicable with the exception that our fault search showed that the average distance to
Rose Canyon fault is approximately 8 miles (13 kilometers).
FOUNDATION RECOMMENDATIONS
Poat-Tensioned Foundation Design
General
The information and recommendations presented In this section are not meant to
supersede design by a registered structural engineer or clvll engineer famlllar with post-
tensioned slab design or corrosion engineering consultant. Upon request, GSI could
provide additfonal data/consultation regarding soil parameters as related to post-tensioned
slab design. Post-tensioned slabs should be designed in accordance with the Post-
Tensioning Institute (PTQ Method. Alternatives to the PTI method may be used If
! "ONI 's7IOS030 =A8 1N3S
~ 30Vd
E0"d 1/.S5
APPENDIX
REFERENCES
rn0c:-9c:-1Jo /3
Geocon Incorporated, 2000, Final report of testing and observation services during
grading, VIiiages R-3 and Q-4. Lots 166 through 238, Rancho Carrillo, Carlsbad,
California, dated April. ~:----:-:--:-:~--::--=-~~-.,--::c·-::-:-----:----_,1
__. 1996a, Ran Carrillo, Villages F, G and L through R, Carlsbad, California, human
health risk assessment, project no. 08053-06-06, dated revised October 4.
__ , 1996b, Rancho Carrillo, Villages F, G and L through R, Carlsbad, California, phase
I environmental site assessment, project no. 08053-06-05, dated August 7 .
• 1993, Rancho Carrillo, VIiiages N, 0, a. R, T, and U, Carlsbad, California,
--preliminary geotechnical investigation, project no. 04354-12-03, dated February 16.
GeoSolls, Inc., 2000, Due dlllgence review, Carlsbad Tract 93-04, Phases 4 and 5, Lots 166
through 210 and Lots 214 through 238, City of Carlsbad, San Diego County,
California, W.O. 2937-A-SC, dated September 21.
Hart, E.W. and Bryant W.A., 1997, Fault rupture hazard zones in California, Alquist-Priolo
earthquake fault zoning act with index to earthquake fault zone maps, California
Division of Mines and Geology, Special Publication 42, undated.
Jennings, C.W., 1994, Preliminary fault activity map of California and vicinity with locations
and ages of volcanic eruptions , scale 1 :750,000, CDMG map series, Map No. 6.
Rick Engineering Company, 2000, Improvement Plans for: Rancho Carrillo, Phases 3, 4 &
5, C.T. 93-04, J.N. 12972, revised February 8.
, 1999, Grading and Erosion control Plans for. Rancho Carrillo, Phases 3, 4 & 5, C.T.
--93-04, J.N.12972, revised June 7.
9/~ 3~'\'d
a.DSoils, Inc.
'.Sf60f~609L '.·oNI 'S7IOS03~ 'A8 lN3S
I
I
I
~
)
r' I
1i
1"0"d %S6
9/t 30\fd
S,60,.:609l. 0s,0,: ,:00c-9c-LJ□ tt-
FINAL REPORT OF TESTING
AND OBSERVATION SERVICES
DURING SITE GRADING
VILLAGES R-3 and Q-4
LOTS 166 THROUGH 238
RANCHO CARRILLO
CARLSBAD, CALIFORNIA
PREPARED FOR
CONTINENT AL RESIDENTIAL.
CARLSBAD, CALIFORNIA
APRIL 2000
! S 160 !~609l !"ONI 'S7IOS030 =AS LN3S
S0"d Y.S5 S1501E509<. 0s:0, ,00c-9c-1Jo
5.0 Seismic: Design Parameters
5.1 The following table summarizell site design criteria obtained from the 1997 Uniform
Building Code (UBC). The values listed in Table 5.1 are for the Rose Canyon Fault which
is identified as a Type B fault and is more dominant than the nearest type A fault due to its
close proximity to the site. The Rose Canyon Fault is located approximately 13 miles
southwest of the site.
TABLE 5.1
SITE DESIGN CRITERIA
Parameter Value UBC Reference
Seiamie Zone FaclDr 0.40 Table 16-1
Soil Profile Sn Table 11>-J
Seismic Coefficient, c.. 0.44 Table 16-Q
Scinnic Coefficient, C. 0.64 Table 16-R
Near-Source FIClor, Na 1.0 Table 16-S
N--Soun:e FIClor, N. 1.0 ' Table 16-T
Seismic Source B Table 16-U
6.0 Retaining Walls and Lateral Loads
6.1 Retaining walls not teStrained at the llop and having a level backfill surface should be
. designed for an active soil pressure equivalent to the pressure exerted by a fluid density of
30 pounds per cubic foot (pcf). Where the backfill will be inclined at no steeper thau 2.0
to 1.0, an active soil pressure of 40 pcf is reconnnendcd. These soil pressures assume that
the backfill materials within an area bounded by the wall and a 1:1 plane extending upward
from the base of the wall possess an Expansion Index of less than 50. For those lots with
finish grade soils having an Expansion Index greater than 50 and/or where backfill
materials do .not confonn to the above criteria, Geocon Incorpora!Ed should be consulted
for additional nocommendations.
6.2 Unrestrained walls arc those that arc allowed to rotate more than 0.001H at the top of the
wall. Where walls arc restrained from movement at the top, an additional uniform pressure
of 7H psf (where H equals the height of the retaining wall portion of the wall in feet)
should be added to the above active soil pressure
6.3 All retaining walls should be provided with a drainage system adequate to prevent the
buildup of hydrostatic fon:es and should be waterproofed as required by the project
Project No. 05845-12-43 -10 -April 2.6, 2000
9/S 30'i'd !s(60(e6oeL !·oNI 'S7IOS030 =AS 1N3S
]
I
J
7
1
l
·\
.. I
I ·I
n J
I
l
90'd
' '
6.4
6.5
6.6
SJ:607:(6091.. 0S:01
architect The use of drainage openings through the base of the wall (weep holes, etc.) is
not recommended where the seepage could be a nuisance or otherwise adversely impact che
propcny adjacent to the base of the wall. A typical retaining wall drain system is ~sented
on Figure 4. The above recommendations assume a properly compacted granular
(Expansion Index less than SO) ba.ckfill material with no hydrostatic forces or imposed
sun:harg,: loa.cl. If conditions different tban tho:;e described are anticipated, or if specific
drainage details arc desired, Geocon Incorporated should be contleted for additional
recommendations.
In generu, wall founda.tioru; having a minimum dq,th and width of one foot 11111y be
designed fur an allCWiable soil bearing pressure of 2,000 paf, provided the soil with.in 3 feet
below lhe base of the wall 1w an Expansion Index of less than 90. The proximity of the >
foUDdal:ion to the top of a slope steeper than 3: I could impact the allowable soil bearing
pressure. Tli='cfim:, Geooon Jncorpon.ted should be consulted where such a condition is
anticipated.
F.;,. resistance to lateral loads, an allowable ~ive earth pressure equivalent t.o a fluid
density of JOO pcf is rccomnmded for footings or shear keys poured neat against properly
compacted granular fill soils or undisturl,ed natural soils. The allowable passive press=
ass11D1es a horizontal surface extending at leaat 5 feet or ~ times the surface generating
the passive prcsaurc, whichever is greater. The upper 12 inches of material not protected by
floor slabs or pavement should not be included in the design for lateral resistance. An
allowable friction coefficient of 0.4 may be used for resistance lo sliding between sci! and
concrete. Thia friction coefficient may be combined with the allowable passive earth
pressure when delc:nnining resistance lo lateral loads.
The recommendations presented above are generally applicable to the design of rigid
concrete or masonry retaining walls having a maximum height of 8 feet. In the event that
walls higher than 8 feet or other types of walls are planned, such as cril>-type walls, Geocoo
fncorporatdd should be consulted for additional recommendations.
7.0 Slope Maintenance
7.1 Slopes that arc steeper than 3: I (horizontal:vertical) may, under conditions which arc beth
difficult to prevent and predict, be susceptfblc to near !!Uliilce (surficial) slope instability.
The instability is typically limited to the outer three feet of a portion of the slope and
usually does not directly impact the improvements on the pad areas above or below the
slope. The occum:nce of Sllificial insmbility is more prevalent on fill slopes and is
generally preceded by a period of heavy rainfall, excessive imgation, or the migration of
Projoct No. 0S845-l2-<13 -11 -April 26, 2000