HomeMy WebLinkAbout2854 RANCHO RIO CHICO; ; CBR2018-0652; Permit(city of
Carlsbad
Residential Permit
Print Date: 05/04/2018 Permit No: CBR2018-0652
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group;
# Dwelling Units:
Bedrooms:
2854 Rancho Rio Chico
BLDG-Residential
2226120400
$7,200.00
Work Class:
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Cogen Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Closed -Finaled
03/16/2018
05/01/2018
TFraz
Plan Check#:
Final
Inspection: 5/3/2018 10:25:36AM
Project Title:
Description: KEHLE: 18 PANEL GROUND-MOUNT PV SYSTEM, 6.21KW
Owner: Contractor:
TRUST KEH LE CONSTANCE TRUST
2854 Rancho Rio Chico
CARLSBAD, CA 92009
PRECISION GENERAL CONTRACTING
SOSO Murphy Canyon Rd, Ste 120
San Diego, CA 92123-4327
858-384-6464
BUILDING PERMIT FEE ($2000+)
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
BUILDING PLAN CHECK FEE (BLDG)
MANUAL BUILDING PLAN CHECK FEE
MANUAL BUILDING PLAN CHECK FEE
SB1473 GREEN BUILDING STATE STANDARDS FEE
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
STRONG MOTION-RESIDENTIAL
Total Fees: $592.06 Total Payments To Date: $592.06 Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
$0.00
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
$97.22
$97.22
$68.05
$68.DS
$128.82
$128.82
$1.00
$1.00
$0.94
$0.94
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: □PLANNING 0 ENGINEERING □BUILDING □FIRE □HEALTH 0HAZMAT/APCD
Ccityof
Building Permit Application Plan Check No.ef>R.2.018-0l05 2
1635 Faraday Ave., Carlsbad, CA 92008 Est. Value 7. 2DO -
Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov
www.carlsbadca.gov Date 0.. -II• -IK ISWPPP
JOB ADDRESS 2854 RANCHO RIO CHICO IUITEI/SPACEt/UNIT# I"" 222 -612 -04 -00
CT/PROJECT# ILOT# I PHASE# I# OF UNITS I# BEDROuMS # BATHROOMS I TENANT BUSINESS NAME I vvNSTR. TYPE I OCC, GROUP
DESCRIPTION OF WORK: Include Squa,e Feet of Atrected Anta(s)
18 PANEL GROUND MOUNT RESIDENTIAL SYSTEM WITH 18 MICROINVERTERS. 6.21kW
EXISTING USE I PROPOSED USE !GARAGE (SF) PATIOS (SF) I DECKS {SF) FIREPLACE IAIR CONDITIONING I FIRE SPRINKLERS
vesO NO□ ves □No□ YES□No□
APPLICANT NAME PETE TSAMBASIS PROPERTY OWNER NAME Connie Kehle -~•-~•h-
ADDRESS ADDRESS
5050 MURPHY CANYON RD #120 2854 RANCHO RIO CHICO
CITY STATE ZIP CITY STATE ZIP
SAN DIEGO CA 92123 CARLSBAD CA 92009
PHONE I FAX PHONE IFAX 8582129753
EMAIL POWERPETE10@GMAIL.COM
EMAIL
DESIGN PROFESSIONAL CONTRACTOR BUS. NAME PRECISION GENERAL CONTRACTING
ADDRESS ADDRESS 5050 MURPHY CANYON RD #120
CITY STATE ZIP CITY STATE ZIP
SAN DIEGO CA 92123
PHONE I FAX
PHONE IFAX 8582129753
EMAIL EMAIL POWERPETE10(mGMAIL.COM I STATE UC.# STATE LIC.# !CLASS B R7q~cef:>-GO r~ 981269
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its Issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a
civil penalty of not more than five hundred dollars {$500}).
WORl<ERS' COMPENSATION
Workenl' Compensation Dedaratton: I hereby affrm under penalty of perjury one of the following declarations:
B I have and will maintain a certlftcate of consent to self-Insure for worilers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
I have and will maintain workers' compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. ___________________ Policy No. ____________ _ Expiration Date ________ _
~section need not be completed if the permit is for one hundred dohars {$100) or less. ILJ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shal! not employ any person in any manner so as to become subject lo the Workers' Compensation Laws of
Califomia. WARNING: Failure to secure workel'I' compensation coverage 11 unlawful, and shall subject an employer to crlminal penalties and dvll fines up to one hundred thousand dollars {&100,000~ In
addition to the colt of compensation, da ed for In Section 3706 of the Labor code, interest and attorney's fees.
,IS CONTRACTOR SIGNAllJRE A/"/11..1.A' I\ I •
I hereby affirm that I am exempt from Contractor's License LBw for the following reason:
□
□
□
I, as owner of the property or my e~loyees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License law).
I am exempt under Section ____ Business and Professions Code for this reasol\:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0Yes Do
2. I {have/ have l\ol) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction {include name address/ phone I contractors' license number):
4. I plan to provide portions of the work, but I have hired the fo11owil\g person to coordinate, supervise and provide the major work (il\clude name I address/ phone / contractors' license number):
5. l will provide some of the work, but I have contracted (hired) the following persons to provide the work Indicated (include name I address I phone/ type of work):
Nf PROPERTY OWNER SIGNATURE □AGENT DATE
'
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration fonn or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Aci.? □ Yes fl( No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air ~ality management district? □ Yes ,f No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? · □ Yes r,No
IF ANY OF THE ANSWERS ARE YES, A FIMAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
APPLICANT CERTIFICATION
I certify that I have read the application and state that the above lnfonnatlon Is com,ctand that the information on the plans Is accurate. I agree to comply with all City oldlnances and state laws relatlngto building construction.
I hereby atJlhoiid, ,epose,,laliie of ltle City of Cal!bad ID enlerupon ltle ab<Ne ""'11ialed property for i1spection pu,poses. I ALSO AGREE TO SA~ INDEMNIFY AND KEEP HARM.ES$ THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: AA OSHA pe,mt s requied for excavalions°"" 5U' deep Md den'ditioo or ronslruction of slruCIJres ,-3 sl,rles in height
EXPIRATION: Eve,y pem,I ssued by 1t1e Building ~ under 1t1e prcMSions of this Code shal expre by limilalion '"1d becolre nul '"1d IIOid ff 1t1e bui~ilg or-aulhaized by such penrit s oot "'"'"">!d .;it;n
180 days from 1t1e dale of such pe,mt er I ltle buidilg or-aulhaized by such pem,l s suspended or abMdoned at a,y tine aller 1t1e "'°" • "'"'., ic:ed for a period of 180 days (Section 106.4.4 Ullllorm a.ildilg Code) .
• AS APPLICANT'S SIGNATURE DATE 311o1g
PERMIT INSPECTION HISTORY REPORT (CBR2018-0652)
Permit Type: BLDG-Residential Application Date: 03/16/2018 Owner:
Work Class: Cogen Issue Date: 05/01/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 10/28/2018 Address:
Scheduled
Date
Actual
Start Date
05/04/2018
05/03/2018 05/03/2018
May 04, 2018
IVR Number: 10168
Inspection Type Inspection No.
BLDG-35 Solar
Panel
057259-2018
BLOG-Final
Inspection
Checklist Item
BLOG-Building Deficiency
057260-2018
Checklist Item
BLDG-Structural Final
BLDG-Electrical Final
BLDG-35 Solar
Panel
056881-2018
BLOG-Final
Inspection
Checklist Item
BLDG-Building Deficiency
056882-2018
Checklist Item
BLDG-Structural Final
BLOG-Electrical Final
Inspection Status Primary Inspector
Passed Tim Frazee
COMMENTS
No stickers
Passed Tim Frazee
COMMENTS
No stickers
Stickers and corrections made 5/4/2018
Failed Tim Frazee
COMMENTS
No stickers
Passed Tim Frazee
COMMENTS
No stickers
Stickers and corrections made 5/4/2018
TRUST KEHLE CONSTANCE
TRUST
CARLSBAD TCT#93-01 RANCHO
CARRILLO VILLAGE J
2854 Rancho Rio Chico
Carlsbad, CA 92009-3004
Reinspection Complete
Complete
Passed
Yes
Complete
Passed
Yes
Yes
Reinspection Complete
Passed
No
Complete
Passed
Yes
Yes
Page 1 of 1
•
DATE: 3/27/2018
JURISDICTION: Carlsbad
PLAN CHECK NO.: CBR2018-0652
✓• EsG1I
A SAFFhuilf Comp;my
SET: I
PROJECT ADDRESS: 2854 Rancho Rio Chico
PROJECT NAME: Kehle 18 microinverter PV system
□ APPLICANT
□ JURIS.
□ PLAN REVIEWER
□ FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
D EsGil Corporation staff did not advise the applicant that the plan check has been completed.
~ EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Pete Tsamasis Telephone#: 858.212.9753
Date contacted: (by: ) Email: powerpete1 O@gmail.com
Mail Telephone Fax Im Person
0 REMARKS:
By: Morteza Beheshti
EsGil Corporation
D GA D EJ D MB D PC
Enclosures:
3/19
Fax#:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad CBR2018-0652
3/27/2018
GENERAL PLAN CORRECTION LIST
JURISDICTION: Carlsbad
PROJECT ADDRESS: 2854 Rancho Rio Chico
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 3/19
REVIEWED BY: Morteza Beheshti
FOREWORD (PLEASE READ):
PLAN CHECK NO.: CBR2018-0652
DATE REVIEW COMPLETED:
3/27/2018
. ~ ..
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and disabled access. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. The approval of
the plans does not permit the violation of any state, county or city law.
• Please make all corrections and submit two new complete sets of prints to:
THE JURISDICTION'S BUILDING DEPARTMENT.
• To facllltata rechecking, please Identify, next to each Item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
□ Yes □ No
• •
Carlsbad CBR2018-0652
3/27/2018
ELECTRICAL and ENERGY COMMENTS
PLAN REVIEWER: Morteza Beheshti
1. Please provide a ground electrode system at the racking array structure. f'C,~ I
2. Please provide voltage drop calculation (to justify Enphase requirements are met) and
indicate length of wires shown on site plan. PG , I
3. Indicate feeders and conduit from combiner box to the service panel. fG. ~
Note: If you have any questions regarding this Electrical and Energy plan review list
please contact Morteza Beheshti at (858) 560-1468. To speed the review process,
note on this list (or a copy) where the corrected items have been addressed on the plans.
'
DATE: 3/27/2018
JURISDICTION: Carlsbad
PLAN CHECK NO.: CBR2018-0652
✓• EsG1I
A SAFl:built Cornpc1ny
SET:I
PROJECT ADDRESS: 2854 Rancho Rio Chico
PROJECT NAME: Kehle 18 microinverter PV system
□ APPLICANT
~ JURIS.
□ PLAN REVIEWER
□ FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
L8J The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
D EsGil Corporation staff did not advise the applicant that the plan check has been completed.
L8J EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Pete Tsamasis Telephone#: 858.212.9753
Date contacted:3/2-r /IV (b~) Email: powerpete10@gmail.com Fax #:
CtMail Telephon~ Fax In Person
0 REMARKS:
By: Morteza Beheshti
EsGil Corporation
0 GA O EJ O MB O PC
Enclosures:
3/19
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad CBR2018-0652
3/27/2018
GENERAL PLAN CORRECTION LIST
JURISDICTION: Carlsbad
PROJECT ADDRESS: 2854 Rancho Rio Chico
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 3/19
REVIEWED BY: Morteza Beheshti
FOREWORD (PLEASE READ):
PLAN CHECK NO.: CBR2018-0652
DATE REVIEW COMPLETED:
3/27/2018
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and disabled access. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. The approval of
the plans does not permit the violation of any state, county or city law.
• Please make all corrections and submit two new complete sets of prints to:
THE JURISDICTION'S BUILDING DEPARTMENT.
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
□ Yes □ No
Carlsbad CBR2018-0652
3/27/2018
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Morteza Beheshti
PLAN CHECK NO.: CBR2018-0652
DATE: 3/27/2018
BUILDING ADDRESS: 2854 Rancho Rio Chico
BUILDING OCCUPANCY:
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
Air Conditionin!l
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
Bid . Permit Fee b Ordinance g y •
Plan Check Fee by Ordinance •
Type of Review: D Complete Review
0 Repetitive Fee
,.. Repeats
* Based on hourly rate
Comments:
D Other
0 Hourly
EsGII Fee
TYPE OF CONSTRUCTION:
Reg. VALUE
Mod.
D Structural Only
i-------1_ ...... 5, Hrs. @ •
$105.00_
($)
$157.501
Sheet 1 of 1
macvalue.doc +
Carlsbad CBR2018-0652
3/27/2018
ELECTRICAL and ENERGY COMMENTS
PLAN REVIEWER: Morteza Beheshti
1. Please provide a ground electrode system at the racking array structure.
2. Please provide voltage drop calculation (to justify Enphase requirements are met) and
indicate length of wires shown on site plan.
3. Indicate feeders and conduit from combiner box to the service panel.
Note: If you have any questions regarding this Electrical and Energy plan review list
please contact Morteza Bebesbti at (858) 560-1468. To speed the review process,
note on this list (or a copy) where the corrected items have been addressed on the plans.
Carlsbad CBR2018-0652
4/23/2018
DATE: 4/23/2018
JURISDICTION: Carlsbad
PLAN CHECK NO.: CBR2018-0652
✓• EsG1I
A Si'\.FE:t)Ullt Comi;f.lny
SET: II
PROJECT ADDRESS: 2854 Rancho Rio Chico
PROJECT NAME: Kehle 18 microinverter PV system
D APPLICANT
....-cfJLJ RI S.
D PLAN REVIEWER
D FILE
~ The plans transmitted herewith have been corrected where necessary and substantially
comply with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed
check list and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at
Esgil Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the
applicant contact person.
D The applicant's copy of the check list has been sent to:
~ EsGil Corporation staff did not advise the applicant that the plan check has been
completed.
D EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:--✓ Telephone#:
Date contacted: ~J) ) Email: Fax #:
Mail Telephone Fax In Person
0 REMARKS:
By: Morteza Beheshti
EsGil Corporation
□ GA □ EJ □ MB □ PC
Enclosures:
4/16