HomeMy WebLinkAboutCD 2017-0003; KAISER PERMANENTE MEDICAL OFFICE BUILDING PARKING LOT EXPANSION; FINAL SOILS REPORT; 2020-11-16GEOTECHNICAL CONSULTANTS
Carson 310.684.4854 | Concord 925.243.6662 | Rancho Cucamonga 909.989.1751
Rancho Cordova 916.631.7194 | San Diego 858.609.7138 | San Jose 408.362.4920
November 16, 2020 RMA Job No. 17-1321-0
Kaiser Foundation Hospitals – National Inspection Services
75 N. Fair Oaks Avenue, Parsons East, 1st Floor
Pasadena, CA 91103
Subject: Compaction Report
Kaiser Carlsbad Medical Office Building – Parking Structure Remodel
6860 Avenida Encinas
Carlsbad, CA 92011
Project Number: W6413/CAP013486
A series of in place density (compaction) tests were taken within the subject site at the locations listed herein from March
29, 2019 to June 5, 2019.
Field testing of the soil and base was by the direct transmission nuclear method, ASTM D6938. The maximum density -
optimum moisture relationship was established in the laboratory by the ASTM D1557 test method. Field density tests
were performed in conformance with previously submitted recommendations provided in the “Preliminary Soil
Infiltration Testing and Pavement Structural Section Report” dated May 10, 2017, RMA Job No. 17-0497.
A summary of the results of all tests performed is attached. The field density tests were taken at locations selected by
our representative and do not constitute certification of compaction of the subject improvements. We have performed
the tests, as previously described, in accordance to generally accepted soil testing practices. No other warranty, express
or implied, is made.
Respectfully submitted,
RMA Group
Slawek Dymerski, PE, GE
Vice President - Principal Geotechnical Engineer
GE 2764
~ ;"~
RMAGroup
Every Project Matters j www.rmacompanies.com
GEOTECHNICAL CONSULTANTS
APPENDIX A
COMPACTION TESTS
~ ;~~
RMAGroup
Every Project Matters I www.rmacompanies.com
GEOTECHNICAL CONSULTANTS
Kaiser Carlsbad Medical Office Building – Parking Structure Remodel November 16, 2020
Job No. 17-1321-0 Page A-1
MAXIMUM DENSITY – OPTIMUM MOISTURE RELATIONSHIPS:
Material
ID
Test
Method1 Description Maximum
Density, pcf
Optimum
Moisture, %
1 M Light Brown Silty Sand 124.6 10.2
2 M Class 2 Base 126.0 9.2
1Test Method
M – ASTM D1557 Maximum Density / Optimum Moisture (Modified)
~ ;"~
RMAGroup
Every Project Matters j www.rmacompanies.com
GEOTECHNICAL CONSULTANTS
IN-PLACE DENSITIES:
Test
No.
Date
Item
Tested2
Location
Test
Method3
Test
Depth,
ft
Moisture,
%
Dry
Density,
pcf
Relative
Compaction,
%
Material
Type
Kaiser Carlsbad Medical Office Building – Parking Structure Remodel November 16, 2020
Job No. 17-1321-0 Page A-2
1 03/29/2019 FL Utility Trench, North West Corner
of Parking Area, South West
Corner of Property
N 0.5 10.9 118.7 95.2 1
2 03/29/2019 FL Utility Trench, Parking Area, South
West Area of Property
N 0.5 4.3 123.6 99.2 1
3 03/29/2019 FL Utility Trench, South West Corner
of Property
N 0.5 5.1 123.5 99.1 1
4 04/01/2019 B Parking Area, South West Corner
of Property
N 0.0 8.8 124.3 98.7 2
5 04/01/2019 B Parking Area, North West Corner
of Property
N 0.0 9.7 120.4 95.6 2
6 04/01/2019 B Parking Area, South West Corner
of Property
N 0.0 10.6 123.1 97.7 2
7 04/03/2019 B Parking Area, North West Corner
of Parking Lot
N 0.0 9.6 120.8 95.9 2
8 05/19/2019 FL ADA Section, North West Parking
Area of West Side of Property,
Phase 2
N 0.0 6.4 121.7 97.7 1
9 05/19/2019 FL ADA Parking Area, North West
Side of Property, Phase 2
N 0.0 8.1 120.4 96.6 1
10 05/19/2019 B ADA Section, North West Parking
Area of West Side of Property,
Phase 2
N 0.0 10.4 123.7 98.2 2
11 05/19/2019 B ADA Parking Area, North West
Side of Property, Phase 2
N 0.0 11.9 122.5 97.2 2
12 06/05/2019 FL Parking Lot, North East Section of
non ADA Area
N 0.0 7.1 120.5 96.7 1
13 06/05/2019 FL Parking Lot, South West Corner of
non ADA Area
N 0.0 8.7 119.3 95.8 1
14 06/05/2019 FL Parking Lot, Center West Area of
non ADA Area
N 0.0 6.5 121.8 97.7 1
15 06/05/2019 FL Parking Lot, North West Corner of
non ADA Area
N 0.0 6.6 119.9 96.2 1
16 06/05/2019 B Parking Lot, Center Section of non
ADA Area
N 0.0 11.5 120.7 95.8 2
17 06/05/2019 B Parking Lot, South East Section of
non ADA Area
N 0.0 11.2 120.2 95.4 2
18 06/05/2019 B Parking Lot, North East Section of
non ADA Area
N 0.0 9.6 120.5 95.7 2
19 06/05/2019 B Parking Lot, North West Section of
non ADA Area
N 0.0 11.6 120.0 95.2 2
2Item Tested:
B – Base FL – Fill
3Test Method:
N - ASTM D6938 (Density of Soil In-Place by Direct Transmission Nuclear Method)
~ ;~~
RMAGroup