HomeMy WebLinkAbout144 REDWOOD AVE; ; CB100971; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-30-2010 Residential Permit Permit No: CB100971
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
Applicant:
Building Inspection Request Line (760) 602-2725
144 REDWOOD AV CBAD
RESDNTL Sub Type:
Lot#: 2042521000
$60,000.00 Construction Type:
RAD
0
NEW
Status:
Applied:
Entered By:
Reference #: Plan Approved:
0
0
SHUSHAN RES-
Structure Type:
Bathrooms: 0
INSTALL NEW ELEVATOR, REMOVE EXIST WALLS IN
GAME ROOM TO
OPEN IT UP, RE-LOCATE WAHSER & DRYER TO GARAGE,
ALTER
CEILING TO MOVE HVAC IN TO ATTIC
Owner:
Issued:
Inspect Area:
Orig PC#:
Plan Check#
ISSUED
05/28/2010
RMA
08/30/2010
08/30/2010
PIPES PLUMBING LANTZ WILLIAM&DIANE FAMILY TRUST 01-31-97
1145 LAW ST 92069
434-3067
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
$463.93
$0.00
$301.55
$0.00
$0.00
$6.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$1.00
144 REDWOOD AVE
CARLSBAD CA 92008
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFO Payoff Fee
PFF(3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnlieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
TOTAL PERMIT FEES
Total Fees: $864.48 Total Payments To Date: $864.48 Balance Due:
Inspector: V\I\ ~ Clearance:
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$48.00
$20.00
$24.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$864.48
$0.00
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as '1ees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020{a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlebad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
revlew, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFICD that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
f es/P.X""tions of which vou havemeviouslv been aiven a NOTICE similar t,-, 1his. or a"''"' whi"h 1he sta1ut0 of limitations has "re• iou-1· · '"''h0rwi"0 "X'"'ir0d.
·~ «~~ ~ CITY OF
CARLSBAD
JOB ADDRESS
Cl/PROJECT #
ADDRESS
CITY
PHONE
EMAIL
PROPERTY OWNER
ADDRESS
E& ADDRESS
\J\. c.4,-...~
FAX
Building Permit Application
1635 Faraday Ave,, Carlsbad, CA 92008
760-602-2717 I 2718 / 2719
Fax: 760-602-8558
www.carlsbadca.gov
SUITE#/SPACE#/UNIT#
#BEDROOMS
ADDRESS
ZIP CITY
PH1 .
EMAIL
-
CONTRACTOR BUS. NAME
ADDRESS
qlP UOl( CITY >(}.I<-
PH NE vO 4"?4-1
EMAIL
Est Value
Plane
Date
STATE ZIP
Cr-,. C\W~
F~~0-411-zn,y.
STcA
(Sec. 031.5 Business and Professions Code: Any City or County which requires a permit to construct. alter, Improve, demolish or repair any struct re, prior to Its Issuance, also requires the
applicant for such permit to file a signed statement tfiat he Is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exemRt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit sub.lects the applicant to a civil penalty of not more than five hundred dollars {:ti500}).
WORKERS' COMPENSATION
Workers' Compensation Declaration: I hereby Blfirrn under penalty of perjury OM of the following declsrBlions:
□ I have and wil maintain a certlfkate of consent to self-Insur. for workers' compensation as provided by Section 3700 of the Labor Code, for the pelformanca oftha work forwhidl tlis pennlt Is issued.
_)>'(have and wlll maintain worklf'I' compensation, as required by Section 3700 of the labor Code, !or lhe perfonnance of lhe work for which this permit ls issued. My WOIUl'S' compena~ !nuance carrier and policy
numberare:l"'"'""'Co ~[ly('1\;ldl••' ~ PoqNo. y,,,,ca \~~2., ExpiratiooOa■ Z,)"3)( !O ~ • I ,
This section need not be com~eled If the pennit is for one hllfldrud dollars ($100) or less.
□ Certificate of Exemption: l certify that in the performance of the work for which this permit is issued, I shalt not employ any person in any manner so as to become sub;ecl to the Workers' Compensallon Laws of
California. WARNING: Failure to secure worklf'I' compensation coverage ls unlawfu nd shall subject sn employer to criminal penaltl11 and civil finn up to one hundred thousand dollars {&100,000), In
addition to the cost of compensation, d.Ars provided for In Ion 3706 abor code, Interest and attorney's fees.
AS CONTRACTOR SIGNATURE 11/ £.-<,
I hereby sffltm that I am exempt ffl1I Contractor's Ucense Law for the following reason:
□ I, as owner of the property or my employees v.;lh wages as their sole compensation, wtH do Iha wor1t and the slrucbJre is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who bu~ds or improves !hereon, and who does such work himself or through his own employees, provided that such irnprovemants are not intended or offered for
□
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder v.;n have the burden of proving did not build or Improve fortha purpose of sale).
I, as O'Mler of the property, am exclusively contracting with liceosed conlraclors to construct the project (Sec. 7044, Business
property who builds or improves th8f80n, and contracts for such pro;ects with conlraclor(s) licensed pursuant lo the Con
ofessions Code: The Contraclor's License Law does not epply lo an owner of
s license Law).
□ I am exempt under Section ____ ,Business and Professions Code for this reason:
1. I personally plan lo provide the major labor and materials for construction of the proposed
2. I (have / have not) tigned an application for a building permit for the propcl59d work.
3.1 heve contracted with the foikMvlg person (!inn) to provide the proposed constr
l □Yes □No
ude name address / phone I contractors' license number):
4.1 plan lo provide portions ot the work, but I have hired lhe following person k>
5. I wiN provide some of the worx, but I have contracted (hired) the followin
lnate, supeMse and provide the major work (include name I address/ phone/ contractirs' license number):
ns to provide lhe WOO.: indicated (include name / address / phone / type of 'Mlfk):
A5 PROPERTY OWNER SIGNATURE CJAGENT DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant Offuturt building occupant requlrvd to 1t.1bmil a business plan, acutely hazardous malerials registration form Of rilk management aod prevention pror;,qm umhr Sedionl 25505, 25533 Of 25534 of 111
Presley• T annar Hazardous Substance Account Adf □ Yes □ No
Is the applicant Of fultn building occupant requlrad to obtain a pennlt from Iha air pollution control district or air quality management district? □ Yes □ No
Is lhe facility to be conslrucled wilhin 1,000 reet of the outer boundary of a school site? □ Yes □ No
F ANY OF THE ANSWERS ARE YES, A FINAL CERTlftCA TE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF TIE OFFICE OF
EMERGENCY SERVICES AND THE AIR POtLUTION CONTROL DISTRICT.
I C8l1lfy that I lla't'8 188d the appllcatlon and Slab! that the abowt Information Is correct and that the lnfonnalloo on the plans Is acant& I ag,N to comply'MIII all Cllyoldlnances and SC.. laws re1atinC to bulldlnC COllltnlclloft.
111818by"'-"">ize--oflleat,,ofCansbad ~--lleaboYe""'11ilnedpmpertyilri1spedblPll!)OOOS. IALSOAGREETOSAVE, NDEMNlfY l'H)KEEf'HARM..ESSll£Cl1YCFCARLS!W>
AGAlNST ALL LIABUTIES, JUOGIIENTS, COSTSl'H) EXPENSES WHICH MAY IN /WYWAY ACCRUE AGAINST SAD CrTY IN CONSEQJENCf CF THE GRANTtlG CF THIS PERMIT.
OSHA:"'1 OSI-I'\ pennit is n,qt.nd ilrexcava1ions""'5'0' deep and de!ooliion orconstn.dion of siucim ""'3 sbies i1 height
EXPIRATION: Eve!)' pennit isMd by lhe Bui<lk,g Ollicial <llderho pro,;,ions of llis Code shale,q,io by-ard beam! OJI and \llid Ille buldilg orWOll< ""'1orized by ll<h penril ls rdCXllTINl100d-
180days loo1 Ile dale of ll<h pennitor ff ~b1Ad7WOll< ""10rizod by~• -alanylina aflorlle WOii< is """"""8d ilr a peli)d of 180 days (Sedi:rl 106.4A Uiilrm ati"9 Code) .
..@S'APPLICANrSSIGNATURE -r ~ 6L" .t).,12::. DATE f\l
City of Carlsbad Bldg Inspection Request
For: 12/21/2010
Permit# CB100971 Inspector Assignment: MC ---
Title: SHUSHAN RES-
Description: INSTALL NEW ELEVATOR, REMOVE EXIST WALLS IN
GAME ROOM TO OPEN IT UP, RE-LOCATE WAHSER &
Type: RESDNTL Sub Type: RAD
Job Address: 144 REDWOOD AV
Suite: Lot: 0
Location:
APPLICANT PIPES PLUMBING
Owner: SHUSHAN FAMILY TRUST 06-02-98
Remarks: A M PLEASE
Total Time:
Phone: 7604343067
Inspector: -~H~l __
Requested By: RUTH BENTLY
Entered By: CHRISTINE
CD Description Act Comments
19
29
~
Final Structural
Final Plumbing
-f='1 '5Viol,,!,e t,tF:~~s o"'-. ~± ~~e,L~"-~•r-k r-24 t.,,,.-,,,.._ioe
Comments/Notices/Holds
Associated PCRs/CVs/SWPPPs Original PC#
lnsQection Histo01
Date Description Act lnsp Comments
12/14/2010 89 Final Combo co MC NOTICE DBL CK SMOKE DETECTORS
10/26/2010 17 Interior Lath/Drywall PA MC ELEVATOR PIT & RELATED WALLS ONLY
10/26/2010 18 Exterior Lath/Drywall AP MC AT EXT. OF ELEVATOR PIT
10/19/2010 13 Shear Panels/HD's WC MC
10/19/2010 14 Frame/Steel/Bolting/Welding PA MC SHEAR AT ELEVATOR SHAFT ONLY
10/19/2010 16 Insulation PA MC AT ELEVATOR SHAFT ONLY
10/14/2010 84 Rough Combo PA PY OK TO SHEAR ELEVATOR SHAFT
10/06/2010 17 Interior Lalh/Drywall PA MC AT GAME ROOM & ELEVATOR SHAFT LID ONLY
10/05/2010 14 Frame/Steel/Bolling/Welding PA MC AT GAME ROOM ONLY, SEE JOB CARD
10/05/2010 34 Rough Electric PA MC
10/05/2010 44 Rough/Ducts/Dampers PA MC
09/22/2010 11 Fig/Foundation/Piers AP MC ELEVATOR PIT ONLY
09/21/2010 11 Ftg/Foundation/Piers co MC COMPLETE RE-INFORCEMENT
09/21/2010 12 Steel/Bond Beam co MC
09/21/2010 24 Rough/Topout co MC
City of Carlsbad Bldg Inspection Request
For 12/14/2010
Permit# CB100971 Inspector Assignment: MC ---
Title: SHUSHAN RES-
Description: INSTALL NEW ELEVATOR, REMOVE EXIST WALLS IN
GAME ROOM TO OPEN IT UP, RE-LOCATE WAHSER &
"'"Vr"'n T-,...AnA,..r"' Al Tll""n ,..r"'II , .. ,.. T-___ ,,I"" I_I\IA,.. II.I
Type: RESDNTL Sub Type: RAD
Job Address:
Suite:
Location:
144 REDWOOD AV
Lot:
APPLICANT PIPES PLUMBING
0
Owner: SHUSHAN FAMILY TRUST 06-02-98
Remarks: A M PLEASE
Total Time:
Phone: 7604343067
Inspector: _ _._fvl-'--e, __
Requested By: RUTH B ENTL Y
Entered By: CHRISTINE
CD Description Act Comments
19
29
39
49
Final Structural
Final Plumbing
Final Electrical
Final Mechanical t--
Date
1012612010
1012612010
1011912010
10119/2010
1011912010
10114/2010
1010612010
10/0512010
1010512010
10/05/2010
09/2212010
09/21/2010
09/2112010
Comments/Notices/Holds
Associated PCRs/CVs/SWPPPs Original PC# LD Cl4). £,.u.J(r ~
111'"1 ~t.;,e..J. ar ,z~ ~
lnsgection Histo[)!
Description Act
17 Interior Lath/Drywall PA
18 Exterior Lath/Drywall AP
13 Shear Panels/HD's WC
14 Frame/Steel/Bolting/Welding PA
16 Insulation PA
84 Rough Combo PA
17 Interior Lath/Drywall PA
14 Frame/Steel/Bolting/Welding PA
34 Rough Electric PA
44 Rough/Ducts/Dampers PA
11 Ftg/Foundation/Piers AP
11 Ftg/Foundation/Piers co
12 Steel/Bond Beam co
lnsp
MC
MC
MC
MC
MC
PY
MC
MC
MC
MC
MC
MC
MC
Comments
ELEVATOR PIT & RELATED WALLS ONLY
AT EXT. OF ELEVATOR PIT
SHEAR AT ELEVATOR SHAFT ONLY
AT ELEVATOR SHAFT ONLY
OK TO SHEAR ELEVATOR SHAFT
AT GAME ROOM & ELEVATOR SHAFT LID ONLY
AT GAME ROOM ONLY, SEE JOB CARD
ELEVATOR PIT ONLY
COMPLETE RE-INFORCEMENT
CUl&hd lQ.0971
06/oa110
fll•-•,_.a,..,..1711~~~~il9,-lleee-.i_-.....,_.,..,,.)Hdom,e,1
~~~ .... --~~~-'. I •!!ii~~~~
P,mi~pil:,,lb-CC\11 ~SF \4:4 &EP'\VQQQ fJT,
A. 1ll~·g((gl1t NmtttQJIP.\.freD·ff'l'lllfffll'fil\tr~l!',.Gi:!(r;f'fti& ~jl YQV i!l!°Owr\tr-
8',il;fe, c;{lljou ,:Ii~~-•• b•id•~ ..,.i·-...c~s,;l,ii;,,taeiti..,p-111.l
-.* ....... ::fe,p A,. Pzt>c>:\M4 W ' flllt-at), .. ,
~-.,tt:eeir l4QI MDG¥ilW,!i e,,go UJ. :Sd::tJ MARc-os,cA 92Q'Jh
&mei>'12K:¢1'31!? 5PC-<jLOSAL .tJ.EJ: ,1't11lM16<2• 5gr ·9 62
tamih: ~,Prffr ~~~-~111111.t tit__ -~or Recon:i
~s ... 'lt(ii~il-id . 1~;3% -a,.,_ ireon. :5\ ,l'u LY)20 I l
:CU.mNiii,,,,t!ie~l!CJ;_iJeclM~Oi'~oi,~ i.,ws.ct;#\e--Stalli.-ar-~,Mr =~-~~:~~~~~,%~~fl!-~~~~=,~~~~ ~;$)~~~~~~:·;;: ~:~~:~!~~
'Bi. cp.,.._.URS:~~..,-.oA<~z:a"(ttt,(ll:f;CJ!t;:.~t,.sddit:1'706}. 1;1111:.-omustce compleniCJ
~in..c011bd0U'bul!Qerfoimer~.-
~~cy~--------------:~...,_1f~""'o°""9f~a-:.9. ~ r,E~. g11 l§{J.,A"-.J .
~A"""m:i 144 fs@\NooD ~vE. .7 G\I SE(,D CA-9Zoof6
"""'"----------"'-------l'tlllde;-7(pc <,So IS-2. ?,,.
Slat~·~"·¢·"~--la-Ci~ICIDlr'UJll:eil··•·Nililillir.~' -----.........:·eiq:,(niaanefaia.' ____ _
:. i-i:.-.aM,;;..~ .•.. ,.-.. -. "ln'tfia.Sbltiui..aa.i:zi.~b 1·1tu·is
r~hd,11'~ . --
• !~.......,1ill'bePL1~1CliGotltMit-6r=:;:,,itMha~~
-~-¥!1a'li111lldl ~-• 'twari.+ee'n-'!It . ~-¢,c whctof,i~-IOrllle-~ · · or'.-apaiv.,;-. • ~_mpo,'ls;arod . . _' · . ·
• I~ ,t,al:111111 . -O<eF--i.Olll-•~111orXIIIC!ltsuell C0l1l0L
-~,6A_.:::=-t---;::-::;W;~:::::..-----!Q• fbo/!J) .
TOTAL P.006
IPEGIAt. INSPECTION PROORAM
AOOReS$0RLEGAlOUCftlPTION: 144: BEDW® Ave·
Pl.AN CHECK NUMBER:· OWNER'S MME: • 5\-:t U'o H4~,.;:·.,___
l, as the owner, or agent of the owner (cont,actort may nm employ llie special ln$pe(lk)rj,
certify tha1 or the arrihitecllenglneer of raam:I, will be 111sponslble for employing the sc,ecial
lnSj)e<ltor{ as raqulr$d byfUnll!D(m8uildlng Code {USC} Section 1701.1 for the c:onstruclion
project Jo,:J~ at the . above. UBC Section 106.3.S.
s~-lJl~--i!:::::===::::...-
l, _. the •:nQh'1891~:hitill<CI t,f l'8001'd, eertlfy thet I hew: 9repared #le followlng ~<.lal
1n1pect1on program as mqulred by U8C Saclion 106 nsbuclion P7oject located at
lhe site llsled above.
1. llsl of work requiring special iiiiptetlo
~ Soils Compllance Pr10rt.o f'oundatlon in
Structural Concrete Over 2500 PIil
f"rfftreHedCano.llta
'Stnictund Ma•omy
Designer Specified
Welding
HIDII atr.ngth llotttnv '
Expansionl£poxy Andlors
Spntyed-Ofl fmtpe'OOflng • Other _____ ·
2. Name{s) oflndlvldual{s) orftrm{s) raBJ)OM1bte1or111. special inspection& li$ted
.ixtw: . (-f(i,,10)
~ ·iz;zs:~:1et~~-4~6:;i~>
'C. -----------------------
3. Dutt•• of the 'SJll!Clal in~pectors for the work llstff auve:
A. &i?!fi£t;i@•: ==~stt~~,:;;:,e~
B. Q2eER"E-Ml¥ ♦ A-Pf'LICtenotJ GE 1502)('( :f'E@-MP:UZ'~.
c. ~J,f:S?F~4=v~v. s FQ8 ~
\
DATE: 08/26/10
JURISDICTION: Carlsbad
PLAN CHECK NO.: 10-0971
EsGil Corporation
In IPartnersfiip witfi C}ovemment for <Bui{aing Safety
SET: I
PROJECT ADDRESS: 144 Redwood Ave.
:!..,APPLICANT
11W' JURIS.
□ PLAN REVIEWER
□ FILE
PROJECT NAME: Enelese Deek/Add Elevator/Remodel Game Room/FAU /Relocate
Washer/Dryer for Shushan Residence
0 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
L8'.I The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
0 The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
L8'.I Esgil Corporation staff did not advise the applicant that the plan check has been completed.
0 Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by: ) Fax#:
Mail Telephone Fax In Person
L8'.I REMARKS: The scope of work has changed. The converting of existing deck ( 110 sq ft) to
habitable has deleted from scope of work. For detail 2/A4 note 3 x 3 x .229 plate washers are
required on owners set as noted in red ink on owners set.
By: Ray Fuller Enclosures:
EsGil Corporation
□ GA □ EJ □ PC (P) 08/23/10
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: 06/08/10
JURISDICTION: Carlsbad
PLAN CHECK NO.: 10-0971
EsGil Corporation
In (Partnersnip witn government for <JJui{tfing Safety
SET: I
PROJECT ADDRESS: 144 Redwood Ave.
□ 6f'fl.lCANT
if JURIS~) □ PLA"ffREVIEWER
□ FILE
PROJECT NAME: Enclose Deck/Add Elevator/Remodel Game Room/FAU /Relocate
Washer/Dryer for Shushan Residence
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Pipes Plumbing
1145 Law Street San Marcos, Ca. 92078
D Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Verne Bentley Telephone#: (760) 434-3067
Date contacted: l.o f 9 /r,) (by: I"'-) Fax #: (760)471,-2865
Mail Telephone v Fax _..,n Person
0 REMARKS:
By: Ray Fuller Enclosures:
EsGil Corporation
0 GA O EJ O PC 06/01/10
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad 10-097.1
06/08/10
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 10-0971 JURISDICTION: Carlsbad
PROJECT ADDRESS: 144 Redwood Ave.
FLOOR AREA:
Convert Deck to Habitable 110 sq ft.
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 05/28/10
DATE INITIAL PLAN REVIEW
COMPLETED: 06/08/ 10
FOREWORD (PLEASE READ):
STORIES: 2
HEIGHT: Existing
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 06/01/10
PLAN REVIEWER: Ray Fuller
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and access for the disabled. This plan
review is based on regulations enforced by the Building Department. You may have other
corrections based on laws and ordinance by the Planning Department, Engineering
Department, Fire Department or other departments. Clearance from those departments may be
required prior to the issuance of a building permit.
Present California law mandates that construction comply with the 2007 edition of the California
Building Code (Title 24), which adopts the following model codes: 2006 IBC, 2006 UPC, 2006
UMC and 2005 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2006 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad 10-0971
06/08/10
1. The following note should be given with each correction list:
Please make all corrections, as requested in the correction list. Submit
three new complete sets of plans for commercial/industrial projects (two sets of
plans for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. Provide a Prescriptive or Performance energy design to show compliance with
current 2008 energy efficiency standards. Appears may need to do a
performance method as glazing exceeds the max 20% allowed for 110 sq ft
adding. Energy calculations to include alternation of existing mechanical
equipment.
3. The regulations require a completed and signed Form CF-1 R (all pages) to be
either imprinted on the plans, included with the plans, taped to the plans, or
"sticky backed" on the plans. Include all applicable sections of the MF-1 R form
with the plans.
4. Unclear how existing deck is supported. Please verify adequate to support
additional glazing/wall framing.
5. Recheck plans for tempered window locations i.e. at either end of corridor as
within 2 ft of doors. Section 2406.3
6. The existing bedroom is shown without light, ventilation and egress as enclosed
deck no longer will allow direct access to exterior.
7. Show dryer vent to the exterior with termination to be a minimum of 3 ft from any
opening. UMC 504.5.
8. The plans did not address existing common wall to proposed addition where it
appears may be removing stucco (shear). Plans should reflect either existing or
proposed braced wall /shear panels to replace any removed lateral resisting
members.
Carlsbad lQ-0971
06/08/10
9. Note on plans if walls being removed are bearing or non-bearing. If bearing then
show adequate horizontal members and note if these are to be flushed or
dropped. If flush then show any required joist hangers, strapping to walls etc.
10. Anchor bolts shall be provided with 3" square x 0.229" plates square washers.
Detail 2/A-4 is reflecting 2 x 2 x3/16".
11. Unclear how much of elevator wall is to be sheared i.e. is it both floors and
what is length? Please clarify and add shear transfer details-note extending to
roof sheathing etc.
12. Please add "Fastener spacing of the sheathing where 4" or less oc occurs" to
special inspection list" and the City of Carlsbad has revised their special
inspection form. See attached.
• Verfiy that the final sets of plans will be stamped and signed by architect of record
also.
• City to place soils stamp on plans at issuance.
• To speed up the review process, note on this list (or a copy) where each correction
item has been addressed, i.e., plan sheet, note or detail number, calculation page,
etc.
• Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly describe
them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction
list? Please indicate: Yes ( ) No ( )
• The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468,
to perform the plan review for your project. If you have any questions regarding
these plan review items, please contact □ref name Ray Fuller at Esgil
Corporation. Thank you.
Carlsbad 10-097.1
06/08/10
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Ray Fuller
PLAN CHECK NO.: 10-0971
DATE: 06/08/10
BUILDING ADDRESS: 144 Redwood Ave.
BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: V-B
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
Deck-Habitable 110 Per Citv Est
Remodel 150
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
Bldg. Permit Fee by Ordinance I • I
Plan Check Fee by Ordinance I • I
Type of Review: 0 Complete Review
D Repetitive Fee ==::G Repeats
Comments:
D Other
D Hourly
EsGil Fee
Reg. VALUE
Mod.
D Structural Only
($)
60,000
60,000
$463.931
$301.551
$259.BOI
Sheet 1 of 1
macvalue.doc +
City of Carlsbad
l@till ◄ii·lltt•i ■l·■■,14§11,i·I
BUILDING PLANCHECK CHECKLIST
DATE:
BUILDING ADDRESS:
J J_ P}ANCHECK NO.: €Jc ( 0 • 91 (
/ \.{L( ,~ WV 0 o/..
PROJECT DESCRIPTION:
ASSESSOR'S PARCEL NUMBER: EST. VALUE: v:; 0, ee 0
~~L( -;z_S ~~Io -!)6
ENGINEERING DEPARTMENT
APPROVAL DENIAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these Items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to comply
with instructions in this report can result In
suspension of permit to build.
D A Right-of-Way permit Is required prior to
construction of the following improvements:
Please see the attached list of outstanding issues
marked with □. Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards. Submit corrected plans and/or
specifications to the Building Dept. for resubmittal to
the Engineering Dept. Only the applicable
sheets have been sent.
By: Date:
By: Date:
By: Date:
By: Date:
FOR OFFICIAL USE ONL
By: L GINEERING AUTHORIZATION TO ISSUE BUILDING PERM~ / / { \)
Date: ~ / /
ATTACHMENTS ENGINEERIN" DEPT. CONTACT PER~"N
□ Engineering Application Name: j KATHLEEN M. LAWRENCE
□ Dedication Checklist Email: kathleen.lawrence""carlsbadca.oov
□ Improvement Checklist Address: 1635 Faradav Avenue, Carlsbad. CA 92008
□ Neighborhood Improvement Agreement Phone: (760) 602-2741
□ Grading Submittal Checklist NOTE: If there are retaining walls
□ Right-of-Way Permit Application and Info associated with your· project, please check
Sheet with the Building Department If these walls
□ Storm Water Applicability Checklist/Storm need to be pulled by separate RETAINING
Water Compliance Exemption Form WALL PERMIT.
1635 Faraday Avenue• Carlsbad, CA 92008-7314 • (760) 602-2720 • FAX (760) 602-8562 @
BUILDING PLANCHECK CHECKLIST
SITE PLAN
~iJJutll ~l ~
1. Provide a fully dimensioned site plan drawn to scale. Show:
_.A:---1\lorth Arrow r,Right-of-Way Width & Adj Streets
/ %Existing & Proposed Structures _9.-.---0riveway widths
C. Existing Street Improvements 1:i Existing or proposed sewer lateral
□
□
_p~ Pi:9Perty Lines (show all dimensions) I. Exi~ting or proposed water service
~asements (show any easements) ~sting or proposed irrigation service
K. Submit on signed approved plans
DWG No. ____ _
2. Show on site plan:
A. Drainage Patterns
1. Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course.
2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum
positive drainage of 2% to swale 5' away from building."
B. Existing & Proposed Slopes and Topography.
C. Size, type, location, alignment of existing or proposed sewer and water service
(s) that serves the project. Each unit requires a separate service; however,
second dwelling units and apartment complexes are an exception.
D. Sewer and water laterals should not be located within proposed driveways, per
standards.
3. Include on title sheet:
A. Site address
B. Assessor's Parcel Number ______ _
C. Legal Description/Lot Number _____ _
D. For commercial/industrial buildings and tenant improvement projects, include:
total building square footage, listing each proposed use and square footage
and each existing use and square footage.
EXISTING PERMIT NUMBER DESCRIPTION
Show all existing use of SF and new proposed use of SF.
Example:
Tenant Improvement for 3500 SF of warehouse to 3500 SF of office.
2
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
BUILDING PLANCHECK CHECKLIST
9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you must complete the attached Industrial Wastewater
Discharge Permit Screening Survey. Fax or mail to Encina Wastewater
Authority, 6200 Avenida Encinas, Carlsbad, CA 92011, (760) 438-3941, Fax
(760) 476-9852.
STORM WATER
Construction Compliance
1 Oa. Project Threat Assessment form complete.
1 Ob. Enclosed Project Threat Assessment form incorrectly completed.
Please make corrections, sign and return.
10c. Requires Tier 1 Storm Water Pollution Prevention Plan. ~ ../-;,il., ,n
Please complete attached form and return (SW ____ .::i9' V' ~ I/ 1
10d. Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal
of Tier 2 SWPPP, payment of processing fee and review by City.
Post-Development (SUSMPl Compliance
1 Oe. Storm Water Standards Questionnaire complete.
10f. Storm Water Standards Questionnaire incorrectly completed. Please make
the corrections, re-sign the questionnaire and resubmit with next submittal.
10g. Project is subject to Standard Storm Water Requirements. See City
Standard Urban Storm Water Management Plan (SUSMP) for reference.
1 Oh. Disconnect Discharges per SUSMP. Do not connect runoff from
impervious surfaces to storm drains without first discharging water over
landscape areas first. See SUSMP.
10i. Minimize use of impervious surfaces per SUSMP. Redesign to reduce the
excessive use of impervious area (pavement) on project. Use a balanced
design of pervious surfaces (landscape area, planters, etc.) and
impervious surfaces. See SUSMP.
10j. Trash storage areas must be designed per City Standards (GS-16) to avoid
contact with storm runoff.
10k. Project is subject to Priority Development Project Requirements.
101. Prepare and submit a Storm Water Management Plan (SWMP). Requires
payment of processing fee and review by City.
5
•
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3RD
D D D 12c. Irrigation Use (where recycled water is available)
□ □ □
1. Recycled water meters are sized the same as the irrigation meter
above.
2. If a project fronts a street with recycled water, then they should be
connecting to this line to irrigate slopes within the development. For
subdivisions, this should have been identified, and implemented on the
improvement plans. Installing recycled water meters is a benefit for
the applicant since they are exempt from paying the San Diego County
Water Capacity fees. However, if they front a street which the recycled
water is there, but is not live (sometimes they are charged with potable
water until recycled water is available), then the applicant must pay the
San Diego Water Capacity Charge. If within three years, the recycled
water line is charged with recycled water by CMWD, then the applicant
can apply for a refund to the San Diego County Water Authority
(SDCWA) for a refund. However, let the applicant know that we cannot
guarantee the refund, and they must deal with the SDCWA for this.
13. Additional Comments: 1. _________________________ _
2. _______________________ _
3-----~--------------------
4. _________________________ _
5. _______________________ _
7
l'.8:1 □ □
l'.8:1 □ □
l'.8:1 □ □
l'.8:1 □ □
l'.8:1 □ □
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CB10-0971 Address 144 Redwood Avenue
Planner Chris Sexton Phone ...,(7'-"6"'0 ... } ""6,,,02,,_---'4""62,,_4.,__ ______ _
APN: 204 202 HJ · J. ()L-/ -).,5J... -/ 0 -0 0
Type of Project & Use: enclose deck Net Project Density:1.0 DU/AC
Zoning: R-3 General Plan: RH Facilities Management Zone: 1
CFD (in/out) #_Date of participation: __ Remaining net dev acres: __
Circle One
(For non-residential development: Type of land used created by this permit:
Legend: l'.8:1 Item Complete
Environmental Review Required:
DATE OF COMPLETION:
D Item Incomplete -Needs your action
YES □ NO □ TYPE
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES □ NO □ TYPE __
APPROVAURESO.NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval: __
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES r8:[ NOD
CA Coastal Commission Authority? YES O NOD
If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103,
San Diego, CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt): Exempt
Habitat Management Plan
Data Entry Completed? YES □ NO □
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and
assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type
impacted/taken, UPDATE!)
lnclusionary Housing Fee required: YES D NO D
(Effective date of lnclusionary Housing Ordinance-May 21, 1993.)
Data Entry Completed? YES □ NO □
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATE!)
H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08
Site Plan:
~□□
~□□
~□□
~□□
~□□
Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements,
existing and proposed structures, streets, existing street improvements, right-of-way width,
dimensional setbacks and existing topographical lines (including all side and rear yard slopes).
Provide legal description of property and assessor's parcel number.
Policy 44 -Neighborhood Architectural Design Guidelines
1. Applicability: YES O NO 0
2. Project complies: YES D NOD
Zoning:
1. Setbacks:
Front:
Interior Side:
Street Side:
Rear:
Top of slope:
Required 20' Shown 20'
Required 5' Shown 5'
Required __ Shown __
Required .1Q'. Shown .1Q'.
Required __ Shown __
2. Accessory structure setbacks:
Front: Required __ Shown --
Interior Side: Required __ Shown --Street Side: Required __ Shown --
Rear: Required __ Shown --Structure separation: Required __ Shown --
3. Lot Coverage: Required <60% Shown <60%
4. Height: Required <30' Shown <30'
5. Parking: Spaces Required g Shown g
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required __ Shown __
D D D Additional Comments__ ~
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTE~'Y\DAT~/;7)
H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev4/08
Ted A , Buchanan • s A ,
architec:t .. e engineering
1 001 Mockingbird Lane San Marcos,
760 -591-9133 fax, 591-9133
NEW CONSTRUCTION
FORTME
NCARB
plallnillg
California
92078-4928
§NY§HAN ffE§!QENcE ffENQY&IfQN§
144 REDWOOD STREET
CARLSBAD, CALIFORNIA
SCOPE PE WORK:
Architectural & Engineering services for the design, construction
documents, calculations and specifications for work as follows:
* installation of new elevator, per owner's selection, with wall &
door modifications.
* foundation work w/ anchors for elev. pit
* structural work tor wall bracing at elev. rails
* accommodations for elec. & hydraulic equipment
* delete and/or relocate selected interior walls and doors
* modify existing deck exterior wall to receive new windows
* relocate, add or delete electrical outlets, switches and fixtures
as required
* add, as required, plumbing and electrical for new washer/dryer
location @ garage
" design changes at second floor ceiling tor new hvac unit at attic
NOTE: the plans clearly show the areas, dimensions, locations, elec. &
mechanical description of the work to be performed and should be referred
to for further clarification.
27 May, 2010
Ted A. Buchanan, Architect
Calf. Lic.#18336