HomeMy WebLinkAboutCDP 2017-0009; SCHIFF RESIDENCE; FINAL SOILS REPORT; 2020-07-01EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC. 10925 HARTLEY ROAD, SUITE "I" SANTEE, CALIFORNIA 92071 . (619) 258-7901 Fax 258-7902 Debra Schiff July 1, 2020 Project No. 17-1106F6 1561 Whittier Avenue Claremont, California 91711 Subject: Final Report of Grading Observations and Soil Testing Proposed Single-Family Residence (Schiff Residence) 221 Normandy Lane City of Carlsbad, California 92008 References: 1. "Grading Plan, Foundation Plan and Details Review, Proposed Single-Familr Residence, 221 Normandy Lane, City of Carlsbad, California 92008", Project Nq. 17-1106F6, Prepared by East County Soil Consultation and Engineering, Incl, I Dated August 14, 2018. 2. "Limited Geoteclmical Investigation, Proposed Single-Family Residence, 221 N01111andy Lane, City of Carlsbad, California 92008", Project No. 17-1106F<5, Prepared by East County Soil Consultation and Engineering, Inc., Datdd December 15, 2017. / Dear Ms. Schiff: ! This report presents the results of field density tests performed on the building pad for ti e proposed single-family residence at the subject site. / In accordance with your request, in-place field density tests were performed in accordance with ASTM D 1556 (Sand Cone Method). Grading was conducted between September 5 and 10, 2018 under the observation and testing of a representitive of East County Soil Consultation /& Engineering Inc. / The results of the field density tests are presented on Page T-1 under "Table of Test Results". The laboratory determinations of the maximum dry densities and optimum moisture contents /of the fill soils are set forth on Page L-1 under "Laboratory Test Results". The approximate test locations are shown on Plate No. 1. / Following clearing and grubbing, i.e. the removal of vegetation, concrete waste and debris from the demolition of the existing residence, subgrade soils were overexcavated to a depth /of approximately 3 to 4 feet below existing grade. The bottom of the excavation was scarified and compacted. · / DEPTH TEST SOIL OFFILL NO. TYPE IN FEET 1.5 2 1.5 ,., 2 .) 4 2 5 3.5 6 2 4 FG 7 2 5 FG Debra Schijjl 22 1 Normandy Lane Project No. 17-1106D5 PAGE T-1 TABLE OF TEST RES UL TS ASTMD1556 MAXIMUM FIELD DRY DRY MOISTURE DENSITY DENSITY ¾DRYWT. P.C.F. P.C.F 8.0 118.7 131.5 7.1 126.4 131.5 7.3 123.5 13 1.5 8.3 119.9 131 .5 9.1 124.7 131.5 7.9 125.1 133.0 8.7 128.6 133.0 FG = FINISH GRADE 3 PERCENT COMPACTION 90 96 94 91 95 94 97 REMARKS Debra Schiff/ 221 Normandy Lane Project No. /7-1106D5 PAGE L-1 LABORATORY TEST RESULTS RESULTS OF MAXIMUM DENSITY AND OPTIMUM MOISTURE The maximum dry densities and optimum moisture contents of the fill materials as determined by ASTM D 1557, Procedures A and B which use 25 blows of a 10-pound slide hammer falling from a height of 18 inches on each of 5 equal layers in a 4-inch diameter 1/30 cubic foot compaction cylinder and Procedure C which uses 56 blows of a I 0-pound slide hammer falling from a height of 18 inches on each of 5 equal layers in a 6-inch diameter 1/13.3 cubic foot compaction cylinder are presented as follows: OPTIMUM MAXIMUM MOISTURE SOIL TYPE/ DRY DENSITY CONTENT PROCEDURE DESCRIPTION LB/CU. FT. %DRY WT. 1/A REDDISH BROWN SIL TY SAND 131.5 8.0 2/A DARK BROWN SIL TY SAND 127.0 9.0 (IMPORT) 4