HomeMy WebLinkAboutCT 06-15; TABATA RANCH; FINAL SOILS REPORT; 2017-10-27TABLE OF CONTENTS
SECTION PAGE
1.0 BACKGROUND ....................................................................................................................... 1
2.0 PROJECT INFORMATION ...................................................................................................... 1
3.0 FILL PLACEMENT .................................................................................................................. 2
4.0 TESTING ................................................................................................................................... 3
5.0 ADDITIONAL CONSTRUCTION OBSERVATION .............................................................. 3
6.0 CONCLUSIONS AND RECOMMENDATIONS ................................................................... .4
7.0 LIMITATIONS .......................................................................................................................... 4
TABLES
TABLE!
TABLE II
FIGURES
FIGURE 1
FIGURE2
COMP ACTION TEST SUMMARY
LABORATORY TEST DATA
SITE INDEX MAP
COMP ACTION TEST LOCATION MAP
\\ESC _ SERVER\Projects\ I O-l 3292G\Compaction Repo1t\Rpt_ Comp (I 0-13292G) I 0-17 .doc
As-Graded Geotechnical Report
Proposed Tabata Ranch Subdivision
Lemon Leaf Drive, Carlsbad California
October 27, 2017
1.0 BACKGROUND
Page 1
CTE Job No. 10-132920
This document provides information regarding testing of compacted fill for the recently completed
Tabata Ranch Subdivision located on Lemon Leaf Drive in Carlsbad, California. The site was
previously graded based on the preliminary geotechnical investigation performed Vinje & Middleton
Engineering, Inc. (Job No. 01-364-P) dated August 2, 2006 and subsequent Update
Recommendations provided by CTE (2016). CTE reviewed the previously prepared report and was
in general agreement with the data, conclusions; and recommendations. CTE previously provided an
interim as-graded document for Lots 1-5 dated July 6, 2015 and modified August 2, 2015 (attached).
Our work was authorized through CTE proposal no. G-3871, dated August 23, 2016.
Based on the previously performed limited geotechnical report and as-grade documents, the site
consists of Quaterna1y Previously Placed Fill soils overlying sedimentary bedrock units of the
Eocene Age. The attached Figure 1 shows the approximate location of the site and surrounding area.
2.0 PROJECT INFORMATION
This report includes a summary of test results and observations perfmmed by CTE during the recent
placement of compacted fill for the proposed strnctures and associated improvements.
Conditions encountered at the site were found to consist of previously placed fill and residual soils
overlying sedimentary bedrock. Previously placed fill and other disturbed near surface soils were
generally found to consist ofloose, silty sand. These materials were removed beneath improvement
areas p1ior to placement of compacted fill as part of the recent grading operation. As indicated,
\\ESC _ SERVER\Projects\l O-l 3292G\Compaction Repo1t\Rpt_ Comp (IO-l 3292G) I 0-17.doc
As-Graded Geotechnical Report
Proposed Tabata Ranch Subdivision
Lemon Leaf Drive, Carlsbad California
October 27, 2017
Page2
CTE Job No. 10-132920
loose and disturbed surface soils and previously placed fill were excavated between elevations 253
(msl) and 272 (msl), depending on location.
The exposed bottoms of excavations were observed, tested, and confirmed ( as appropriate) prior to
placement of the compacted fill. Exposed areas to receive fill were then scarified, moisture
conditioned, and compacted in general accordance with project requirements. Following subgrade
preparation, fill materials were moisture conditioned, placed in lifts, and compacted. Excavations
and compaction within the improvement areas were conducted with a D8 dozer and a 980 loader.
Mountain Movers was the grading contractor for the project.
Grading on the subject site also consisted of parking and drive areas, minor excavations, wall
backfill, and utility installation. Minor grading and compaction testing for utility tie-ins conducted
in the adjacent Lonicera Street right-of-way is also documented herein.
3.0 FILL PLACEMENT
Fill soils consisting of onsite stock piled materials were generally placed in uniformly compacted
lifts at above optimum moisture content. Compaction was performed to the appropriate minimum
values (90% for building pad areas and 95% for pavement sub grade areas), as determined by ASTM
D1557. Grading was perf01med using standard construction equipment, followed by mixing,
moisture conditioning, and compaction procedures. Backfill placement and compaction were
performed in overall confo1mance with geotechnical recommendations.
\\ESC _ SERVER\Projects\1 0-l 3292G\Compaction Repo1t\Rpt_ Comp ( I 0-132920) 10-17.doc
As-Graded Geotechnical Report
Proposed Tabata Ranch Subdivision
Lemon Leaf Drive, Carlsbad California
October 27, 2017
4.0TESTING
Page 3
CTE Job No. 10-132920
Testing was performed to supplement field observations. Testing of compacted fill addressed by this
repo1t was conducted, as scheduled by the contractor, between October 19, 2016 and May 10, 2017.
Field-testing of the compacted fill soil was conducted in accordance with ASTM D-6938-08a
(nuclear method). Results of the field-testing indicate that fill materials were compacted to at least
90 percent or 95 percent of the laboratory maximum dry density, as required, in accordance with
ASTM D 1557. Fill material was generally compacted at above optimum moisture content.
Tabulated results of the field compaction testing are provided in the attached Table I, "Compaction
Test Summary." Laboratmy determination of the reference compaction values for the fill materials
is provided in Table II, "Laboratmy Test Results." Figure 2 shows the approximate location of the
compaction tests performed.
Based on site observations, it appears the Expansion Index (E.I.) for onsite materials were generally
found to have a very low expansion potential (EI < 20).
5.0 ADDITIONAL CONSTRUCTION OBSERVATION
Additional grading and backfilling, if any, should be observed and tested by CTE. In addition, prior
to any significant future development, an appropriate update geotechnical investigation and report
should be completed.
\\ESC _ SERVER\Projects\l O-l 3292G\Compaction Repo11\Rpt_ Comp (I O-l 3292G) 10-17.doc
Page 5 As-Graded Geotechnical Report
Proposed Tabata Ranch Subdivision
Lemon Leaf Drive, Carlsbad California
October 27, 2017 CTE Job No. 10-132920
Attachment: Interim As-Graded Geotechnical Report
Proposed Tabata Ranch Subdivision
Lemon Leaf Drive, Carlsbad, California
CTE Job No. 10-121010, dated July 6, 2015, Modified August 2, 2015
References: Summary for Testing of Compacted Fill for Lot 5
Proposed Tabata Ranch Subdivision
Lemon Leaf Drive, Carlsbad California
CTE Job No. 10-132920, dated February 6, 2017
Summary for Testing of Compacted Fill for Lots 1 and 2
Proposed Tabata Ranch Subdivision
Lemon Leaf Drive, Carlsbad California
CTE Job No. 10-132920, dated November 16, 2016
Summary for Testing of Compacted Fill for Lot 3
Proposed Tabata Ranch Subdivision
Lemon Leaf Drive, Carlsbad California
CTE Job No. 10-132920, dated May 10, 2017
Update Geotechnical Recommendations for
Proposed Tabata Ranch Subdivision
Lemon Leaf Drive, Carlsbad California
CTE Job No. 10-132920, dated August 26, 2016
Geotechnical and Update Repo1t and Grading Plan Review
Proposed Tabata Ranch Subdivision
Lemon Leaf Drive, Carlsbad, California
Vinje & Middleton Engineering Job# 01-364-P, dated August 2, 2006
Preliminary Geotechnical Investigation
Proposed 4-Lot Subdivision, Tabata Ranch
Off Camino De Las Ondas and Lonicera Street, Carlsbad, California
Vinje & Middleton Engineering Job# 01-364-P, dated October 24, 2001
\\ESC _ SERVER\Projects\10-13292G\Compaction Report\Rpt_ Comp ( I O-l 3292G) I 0-17.doc
TABLE I
COMP ACTION TEST SUMMARY
Job Name: Tabata Ranch Job No. 10-132920
Job Address: Lemon Leaf Drive, Carlsbad Ca Date: 10/27/2017
Date Test Location Elevation Density Moisture Relative Soil
No. or Depth pcf Content Compaction Type
Feet %Dry %
Weight
10/19/2016 1 S.E Side Lonicera St AC 139.6 -96% 1
10/19/2016 2 N.E Side Lonicera St AC 138.8 -96% 1
10/19/2016 3 N.E Side Lonicera St AC 139.3 -96% 1
10/19/2016 4 S.W Side Lonicera St AC 137.8 -95% 1
10/19/2016 5 CTR Westside Lonicera St AC 139.9 -96% 1
10/19/2016 6 N.W Side Lonicera St AC 139.2 -96% 1
10/19/2016 7 N.E Side Lonicera St AC 138.4 -95% 1
10/27/2016 8 Lot #1 Pad SG 118.9 10.4 94% 2
10/27/2016 9 Lot#l Pad SG 115 .5 10.7 92% 2
10/27/2016 10 Lot#2 Pad SG 118.4 10.4 94% 2
10/27/2016 11 Lot #2 Pad SG 117.7 10.3 93 % 2
1/31/2017 12 Lot#5 SG 109.1 13.1 95% 3
1/31/2017 13 Lot#5 SG 110.7 13.3 96% 3
1/31/2017 14 Lot#5 SG 109.8 13.3 95% 3
5/10/2017 15 Building Pad #3 FG 110.6 12.7 96% 3
5/10/2017 16 Building Pad #3 FG 111.3 12.5 97% 3
10/26/2017 17 1st Level Retaining Wall Lot 3, NW SG 106.3 13.8 92% 3
10/26/2017 18 1st Level Retaining Wall Lot 3, N SG 104.9 14.3 91 % 3
10/26/2017 19 1st Level Retaining Wall Lot 3, NE SG 104.5 14.0 91 % 3
10/26/2017 20 1st Level Retaining Wall Lot 3, E SG 104.7 13.7 91% 3
10/26/2017 21 Upper Level Retaining Wall Lot 3, NW SG 105.2 14.3 91% 3
10/26/2017 22 Upper Level Retaining Wall Lot 3, NE SG 104.2 13.9 90% 3
10/26/2017 23 Upper Level Retaining Wall Lot 3, NE SG 104.6 13.8 91% 3
10/26/2017 24 Upper Level Retaining Wall Lot 3, E SG 103.9 14.2 90% 3
10/26/2017 25 Upper Level Retaining Wall Lot 3, E SG 104.8 14.4 91% 3
** TEST FAILED, SEE RETEST
Job Name:
Job Address:
Sample No.
2
3
Tabata Ranch
TABLE II
LABORATORY TEST DATA
Job No. 10-132920
Lemon Leaf Drive, Carlsbad Ca Date 10/11/2017
Maximum
Dry Density
pcf
145.1
125.9
115.2
Optimum
Moisture
Content
%wt
9.5
12.3
2
Soil
Description
Asphalt Concrete
Light Brown Silty Sand
Yellowish Brown Silty Sand