Loading...
HomeMy WebLinkAboutDWG 402-2P; CUP 258C; LA COSTA RESORT & SPA - BALLROOM BUILDING; 01-34, ESTRELLA DE -~· -TT ~ ?:WW: ____________.. a GP1 I I I_ I I I -i-.• \ h I I I ' I I ' , , ' , ' ' ' ' , ' WATER USE CALCULATIONS: TOTAL WATER USE, MAWA= 432 X '1::1.8 X 91,311 X 0b2= EAWU= 1-lYDROZONE "I TURF 432 X .1rD X 1'1::1,465 X rZJb2/ .1'1::1= 1-lYDROZONE "2 5!-lRU6 432 X .4'1::1 X 8'1::1,912 X rZJb2/ .1rD= EAWU TOTAL, 1,951,953 GAL/YEAR 28'1::I ,295 GAL/YEAR 1,238,369 GAL/YEAR 1,518,664 GAL/YEAR MAR I I ROAD ,L/ I /. i 1 1 /A.."-z IA" LIM l~---GF----WGK-K t.-1;' 1 / 4." I r I 1,. I , ,, , ' I 11· PRESSURE LOSS CALCULATIONS, METER 1-l.G..L. METER ELEVATION F51., METER 318.'1::I' 52.'1::I' 115 PSI I 2' WATER METER 6ACKFLOW PREVENTER VAi yE "629 4!;, c;,FM 1.5 2' PVC 5Cl-l 315 MAINLINE (1,120' LF) REMOTE CONTROL VALvE FITTINGS PRESSURE REQUIRED AT 1-lEAD ELEVATION GAIN LATERALS MISC. TOT AL FRE55URE LOSS STATIC FRE55URE RESIDUAL PRESSURE 11.'1::I 11.92 2b 3.5 3'1::1.'1::I 3.'1::1 8.'1::1 4.'1::1 81.5 P5I 115 F5I 33.5 PSI I I I I I l ... I (Z) lb SCALE: 32 IRRIGATION LEGEND 5YM60L MFG/MODEL NO, ca i:!t> A RAIN6I!'11D lee>4-8 a:, &, o (§) RAIN6f!'i1D IW4-1'1::I ffi & 6 0 RAIN61!'11D 18'1::14-12 d::, &, o @ RAINSIRD 18'1::14-15 q,. RAIN6I!'11D la'1::14-8VAN & 1-lUNTER FCisF-ADJ-5LA l!ll !-ll.lNTER FCisF-ADJ-6LA -$-!-ll.lNTER FCisF-36V-5LA • RAJN6f.RD 1812-14'1::12 □ RAIN61RD 1812-SCST RAIN61RD 18'1::16-5 'v T Y 0 RAINSIRD l8'1::16-8 '¢' -+ ~ ® RAIN61RD 1006-1'1::I Y' 't -.!/ @ RAINBlRD 18'1::16-12 'r RAIN61RD IW6-8VAN PATTERN Q,T,1-l Q,1-l Q,T ,l-1 T Q 9'1::1" 18'1::I" 36'1::I" FLOOD STREAM Q,T ,l-1 T ,l-1,F Q,T ,l-1,F Q,T ,1-1,F Gl ti ♦ RAIN61RD IW6-l65LA 1-l, F RAIN61RD IW6-225LA Gl, 1-l DESCRIPTION 4' FOF-UF TURF SPRAY 4' FOF-UF TURF SPRAY 4' FOF-UF TURF SPRAY 4' FOF-UF TURF SPRAY 4' FOF-UF TURF SPRAY 4' FOF-UF TURF ROTOR 4' FOF-UF TU!'<!' ROTOR 4' FOF-UF TURF ROTOR 6' FOF-UF 51-lRUS 6U66LER 6' FOF-UF 51-lRUS 6U66LER 6' FOF-UF 51-lRUS SPRAY 6' FOF-UF 51-lRUS SFRAY 6' FOF-UF 51-lRUB SPRAY 6' FOF-UF 51-lRUB SFRAY 6' FOF-UF Sl-lRU6 SPRAT 6' FOF-UF 51-lRUB SPRAT 6' FOF-UF 51-lRUB SFRAY PSI 30 3'1::1 3'1::1 3'1::1 3'1::1 5'1::1 5'1::1 50 30 3'1::1 3'1::1 3'1::1 3'1::1 3'1::1 = 3'1::1 3'1::1 GFM 26, .36, .52 .40, .I¾!) b!:>, l.'1::1, 1.3 l.3'1::1 0.14 2.1 2.8 2.1 0.50 rZJ.5'1:) 8' 10' 12' IS' 8' 26' 3'1::1' 28' J2, J3, .14 5 1 .36, ..&2, 1JZl4 8' .4, .52, .8, lb 1'1::1' b5, l.'1::1, 1.3, 2b 12' IZ>.14 6 1 1b'1::1, 32 lb'1::1, 32 16' 2'1::1' PRESSURE MAINLINE IN PLANTER AREA, 3/4' TO 1-1/2', FVC SCI-I 4'1::1, 2' AND LARGER USE FVC CLASS 315, BURY SLEEVED FVC MIN. 18' BELOW GRADE FOR PEDESTRIAN, 30' FOR VEl-llCULAR NON-PRESSURE LATERAL FVC 5Cl-l 4rD WITl-l FVC 5Cl-l 40 FITTINGS. 6URY 5LEEvED FVC MIN. 12' BELOW GRADE FOR PEDESTRIAN, 30' FOR vEl-llCULAR SIZE NOTED. FIFE SLEEVING, FVC 5Cl-l 8'1::1 FOR MAINLINE AND WIRES UNDER VEl-llCULAR PAVING, 5Cl-l 4rD FOR MAINLINE, WIRES AND LATERALS UNDER PEDESTRIAN PAVING. EXTEND 12' BEYOND PAVING. WIRE SLEEVING, FVC 5Cl-l 8'1::1 UNDER vEl-llCLE PAVING W/ 3'1::1' COVER, SCl-l. 4'1::1 UNDER PEDESTRIAN PAVING WI 18' COVeR RAIN6IRD FE6 SERIES REMOTE CONTROL VALVE. SIZE NOTED. Nteco LINE SIZED 6ALL VALvE NELSON 1643 QUICK COUPLING VALVE-3/4' GRISWOLD "223'1::I PRESSURE REGULATING MASTER VALvE. <NORMALLY CLOSED) -2'. SET AT 18 PSI DATA INDUSTRIALS FLOW SENSOR "220f' 150 (2)-RAIN6IRD ESF-4'1::IMC-4'1::1 STATION AUTOMATIC CONTROLLERS WITl-l RSD-6Ex RAIN SENSOR 51-lUT-OFF DEVICE, WALL MOUNT IN A '5TRONG60X' ENCLOSURE MODEL• 56-1855, SEE DETAIL FE6CO 825,A REDUCED PRESSURE 6ACKFLOW PREvENTER -2' PROPOSED 2' RECYCLED WATER METER-vERIFY LOCATION IN FIELD PRIOR TO INSTALLATION REFER TO CIVIL ENGINEERING DRAWING,5 FOR MORE INFOl'<MATION VALVE NUMBER ~ FLOW IN G.F.M. ~ VALVE51ZE NOTES I. USE FOF-UF 1-lEADS W!Tl-l 'SAM' BUILT-IN Cl-lECK VALVES TO FREvENT LOW 1-lEAD DRAINAGE, 2, INST ALL RAIN61RD PCS SCREENS A5 NECESSARY IN ORDER TO FREvENT OVERSFRAY ONTO WALK, WALLS, COLUMNS, ETC. 3. ALL LATERAL LINE AND MAINLINE INSTALLED UNDER AC PAVING TO BE PROVIDED WITl-l FIFE SLEEVING. (2 TIMES LINE SIZE). INST ALL FER 5LEEVING, REQUIREMENTS IN LEGEND ABOVE. 4. INST ALL FOF-UF5 WITl-l IN 1'1::1' OF ALL PEDESTRIAN USE AREAS. FER CITT OF CARL56AD LANDSCAPE MANUAL. 5. NOTIFT LANDSCAPE ARCl-llTECT PRIOR TO INSTALLATION IF ANT Dl5CREFANCIE5 OCCUR FORREST K. HAAG, ASLA, INC. LANDSCAPE ARCHITECTURE LAND PLANNING 1254 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 P: (949) 376-9066 F: (949) 376-9067 ·•::1,i,24'·,\,(".:i .. \ ··~ ·'f !!ff)iJy·•~ i§f-...j,e-...A~gf~.APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. PLAN SHEET KEY ..,~;,a, f';;;:;;1'-~]'fu>I u: wn "AS-BUILT" . I TITLE ________ _ DATE REVIEWED BY: INSPECTOR DATE fSHm7 CITY OF CARLSBAD SHEETS 1----+-----1-----------------+---+---1----t----1 ~ PLANNING DEPARTMENT ::====:..::::::::=:::::::::::::::::::::===:::::::::===::::::'..'.::~~ LA IRRIGATION PLAN BALLROOM COSTA RESORT & SPA CARLSBAD CALIFORNIA I ~~ 461----1---+----------------+----lf---+--+-----1~A~S~S=IS~T=A=NT::::::P=L=A=N=N~IN=G::::::::D=IR=E=C=TO=R::::::===::;-;:==D=A=TE==='. 1 /16" -1'-0" OWN BY: ---PROJECT NO. DRAWING NO. CHKD BY: __ _ RVWD BY: CUP258(C) 402-ZP DATE INlllAL REV1S1ON DESCRIPT1ON DATE INlllAL DATE INlllAL ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL "" r I 1/ I \ I . r -..1 -- I ,3/4' I 3/4' I . ----I : ---- / I I ' I ' ' ! ' I 3/4" 3/4" 3/4" /4" 3 4" 3/4 3 4" 3/4" ! I I ;'--f--J ! I ' i \ BALLROOM 1 e, I I l l lb SCALE: 1 32 48 1 /16" -1 '-0" FORREST K. HAAG, ASLA, INC. LANDSCAPE ARCHITECTIJRE LAND PLANNING 1254 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 P: (949) 376-9066 F: (949) 376-9067 ',·,· .. ~Y~',t"c,'i :,..,,,ye,.' ,,.. .. ~~,;x1~1i1:t'? ·••---r--1 I , , APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. PLAN SHEET KEY "AS-BUILT" TIRE _______ _ DATE REVIEWED BY: INSPECTOR DATE CITY OF CARLSBAD SHEETS ~tttttttttttftttttttttt====================ttitttt~t====t====~t===~ ~I ~~od.!I ==~P~LA~N¥N~1N~G=#,D~E~PA~R=™~E~N~T~==:...':::::~t=l IRRIGATION PLAN DATE INITIAL REVISION DESCRIPTION ENGINEER OF WORK BALLROOM LA COSTA RESORT & SPA F===±===E======================i====±===t===±==3 ~E~~C4'AR~L~S?,;B~'AD~~CAL~IF~O~R=N=IA~=:=:~, A <-/-J-Qs ~~',-,--:::~~~::::--;:;;;:;;::;:;:;:;:;;;----DATE t==+==+====-----------==j==1==t==~==~ ASSISTANT PLANNING DIRECTOR t==i==~====----------===t==t:=::t~:=t;~ DWN BY:___ PROJECT NO. DRAWING NO. DATE INITIAL DATE INITIAL CHKD BY: ---CUP258(C) 4O2-2P C11Y APPROVAL RVWD BY: OTHER APPROVAL ~ ----------- ·.'I ~ 'I' .. i " ,, "I 0 ' I' I ; f-!. --+----; -----+-----1--1-' - ---'-----.-----------.- 1-i ' ' :3/4 '-----r-----;---:--------1- '' --,--,.1~,',•----! i ' ------1- \ \ ~~~nMJC!dJ! .. -IL~' ~==~I]WJ(J.Jj"•· .JlQ!;;==~==~-~OM[J,JL"···•···Jl[~' ===~OJY][J~'7 ........... JL[~~~ajil ; BALLROOM ~ I "'----,!"'!"'~!"'!', ------MATCHLINE ----SEE SHEET 24 ! i ", I iii I --- ,!---+-@ 0-lx I _J I 1'' I \ 3/4' II \ \ --- ' 3' 4 \\\\ ,,..., \:;1 31@ SHRBY \ \ \ 1 1&£" / I I 1" / I // / / / / ' I , I . ;' , I / 3;/4' I , I / I I :.......---1 1" "" . 'C'J' ' ' . . r· • I : 1 1y2" ! ' ' 51 ' I i ' ! • i ' I I ' I ' ' ' 1,, I CJ I !· I I '\ ~· I! J. \ SCALE: 1 /16" _ 1 '-0 DAlE INlllAL ='-'--"==----...:...'-'--::_ _ __:_ ENGINEER OF WORK POINT OF CONNECTION - CONNECT TO FROF05ED 2' FOTASLE WATER METER REFER TO SEWER AND WATER FLANS PROVIDED 6Y RICK ENG,INEERING =-, INC., CITY Du.t:.. NUM!SER 4'?n-2F, 51-lEET S. FOR FURTI-IUR LOCATION INFORMATION. VERIFY LOCATION IN FIELD F!'itlOR TO INSTALLATION. CONNECT 6ACKFLOW PREVENTER, MASTER VALVE, QUICK =UFLER, FLOW SENSOR AND G.ATE VALVE, IN 51-lF<U6 AREA AS SI-IOWN IN FOfNT OF ~CTION DETAIL, SI-IEET 26, FER CITY STANDARDS. LOCATE ALL GATE VALVES, REMOTE =NTROL VALVES AND QUICK COUPLERS IN PLANTER AREAS, FLAN 51-iOWN FOR CLARITY ONLY. EXISTING STATIC PRESSURE DESIGN PRESSURE MAXIMUM FLOUJ SET PRESSURE REG,ULATOR AT 81 FSI. IIS FSI 82 FSI 4S GFM WATER METER INFORMATION 06TAINED FROM CARL56AD MWD FU6LIC WORKS DEFT., =NTACT, &KIF F<USSELL AT 16.z>-438-2122 AND RICK ENGINEERING CO., CONT ACT, RAUN CONNELY AT 61~-688-1481. LANDSCAPE CONTRACTOR TO VERIFY STATIC UJATER PRESSURE AND LOCATION OF WATER METER AND 15 TO NOTIFY LANDSCAPE ARCI-IITECT OF ANY DISCREPANCIES PRIOR TO ~ENCEMENT OF CONSTRUCTION. FAILURE TO DO SO MAY RESULT IN CI-IANGES TO IRF<la.ATION SYSTEM. COST FOR TI-IESE CI-IANGES UJILL 6E Tl-IE RE5FON5161LITY OF Tl-IE CONTRACTOR. CONTROLLER LOCATION- 111 VOLT 2 AMF 6.z> CYCLE FOUJEl'I< F~VIDED 6Y OWNER. IRRIG.ATION CONTRACTOR TO MAKE FINAL I-IOOK-UF. WALL MOUNT ON OUTSIDE OF WALL IN VANDAL RESISTANT ENCLOSURE. VERIFY LOCATION IN FIELD WITI-I OWNER'S REPRESENTATIVE/ LANDSCAPE ARCI-IITECT. PROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS, ~ 1 LA PLAN SHEET KEY {')!r ~~=\ _./1'---'"'·· TITLE A 1,, f, I I ' 'i' /~'I 1/ , 1,6 n;• I "AS-BUILT" REVIEWED BY: INSPECTOR CITY OF CARLSBAD PLANNING DEPARTMENT IRRIGATION PLAN BALLROOM COSTA RESORT & CARLSBAD CALIFORNIA a DAlE DAlE SHEETS SPA ASSISTANT PLANNING DIRECTOR DAlE INITIAL DAlE INITIAL REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL DWN BY: __ _ CHKD BY: __ _ RVWD BY: PROJECT NO. CUP258(C) DRAWING NO. 4O2-2P ~ N I-w w I (/) w w (/) w z _J I u I- <( 2 I I I -1-------~-t--, ' I ' I "'---½,'~-ri·----, ; 1 r I l\.>J '--P.firi / i / ' I !.' / I ! ! ' I, ! ! / ! I 3,( \:) I ,I ' /I I ! I I ; I I I // I I I I I I I 1'' 3 I I ! ! ~ ,_, l0 I ! I I ! f,,,, I j ,. i ---~" i / ! :/ / ! l~ ! I 3 4" ! 4" LIMIT OF WORK I 1 f 11" __ / _ _;j~-- I 4" ! I ! /4 3/4 QJ 'v- i t / I I / < J I 3 4" 3 4" 3 4" 3 4" I ' I -, - --F@ifll\i ! ;, 31 ® TURF7/'.' 31~1 SHRB7T' ii r'i I, I I 1, I, ,, i\ ' I I, !I " ' 1 I I \ (J 0 en ----\ y 3//'I-" I \ \-...-\ \ ' ' \ \ '\ _/ 3 I \ l 4'' \ lF~lii=/9 ~~~==;',',l/==i~~=i=='-"' =3~4~,,~~>=3?z~4=•~==;',il===¢-'===:=>"'=:\;,=''¢='~~~~?i1?'=?'==it='"''==;==',i,'==,==:'i.'=::::;::'ir':1:=~• f='\!==¥=="-r':~=··~-t::::.;="t.=:;:"'\=±""-----'i:;\[l_._1 , ! ·7 i " ! '-----I/" ! ,/ ,/ i, I I ~:l3j-<1X\' / I ' I" ' I ~ ,, 4" 3 4" ··-'---' ~--'--------L---f'--llL4.'.,_' _,,.,111+---/ ~,l _/----+------+------+-1 +-'--+-~3'-1--_J/___,___4',,!l ',,i_ '-' 1 < ... □ □~ □ □ 0 □ 0 0 ,_ ,_ /T1 r I I I 6 ® ; /r I 1'' I ~r' + I _; 1 , l 11---- ?] 0 y 0 .....-1 -ri-1--"r --~I..,_ 1 --;------,,-11 1 ...,.... -11 2,, I ,I " 2" I I ' ~ --,-;:.+:=;.;==;.;==;t;:.=;~=t,~~;.;==;i~=;i¢==p;;::::::=,.t==,.g::;::t,,;;=.;'76,~=?'ic==' =?'i=/=/1 /='t-i==t:o;==,a~g~:::::;;..==j!;J's;==:;or=~c=~4r'""--\-------' " ~ l 3/4" ttwm B g "':1ff'ftffl1ffl 'm Im! g ! 7:J51Jl't'm iffl R li'mmi1 SM -a ½¥ rm /2 Cl nrnrffiil1'1't a a % @ !IL I !m illE ~ LIMIT OF WORK 1 1 I f (Z') 32 l FORREST K, HAAG, ASLA, INC. LANDSCAPE ARCHllEClURE LAND PLANNING 1254 N, COAST HIGHWAY LAGUNA BEACH, CA 92651 'i§~:::µa--.Jq:;\'}-~Af'PROVED FOR PLANTING AND P: (949) 376-9066 F: (949) 376-9067 ~~r~~~1:;-t~(t)?~f~~?;>: . ~r1tk~t:1 . .11.i1f-i''.-·.1\•:::--;;::,::-,;--·· · . i I ' : IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. ~ 2 LA A PLAN SHEET KEY ~· •~--Y1(s1frrl 1n -~~1,1),D ]1'.'hM tH;:;;,'o;;•-,;;W; l'J9 h , I... \ --< \ ,j "AS-BUILT" TITLE DATE REVIEWED BY: INSPECTOR DATE CITY OF CARLSBAD SHEETS PLANNING DEPARTMENT IRRIGATION PLAN BALLROOM COSTA RESORT & SPA CARLSBAD CALIFORNIA L./-3-03 481-------+--------<~-----------------+----+---1----1----< ASSISTANT PLANNING DIRECTOR DATE OWN BY: SCALE: 1 /16" -1'-0" DA lE INl11AL REVISION DESCRIPTION PROJECT NO. DRAWING NO. DAlE INlllAL DAlE INlllAL CHKD BY: RVWD BY: CUP258(C) 402-2P ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL 3/4" 3/4" =I= I -I- I 3/4" I I I I 3/4:': ii j !!l, ! i L=-- 3/4" ,. C -------~L--' /"~ / 3/4" 3/4" 3 4" I I I I I I I I I I I I 3 4'j I I I I I I I 3/4' I I 1" " 3/4" 3/4" 3/4" I I I / 11 I I/ 1 11~·: -J-_ --o s~--.,1 ______ Q.._ ________ _ I 3/4" EL CAMINO REAL --~I =1r=wi~·c· b.ccc---~ iiJ ------~--11- : i --E~-v---~·~-~ ---------~ -------_!]_ --- ------------i I ---------------------------------I I : i -,.- i 1 3/4" I I 3/4" I I 3/i I I I I I I I LIMIT OF WORK ,-,, -,------ ~~r---'~ i 3/4" I I I I "' ,-..........._ ! ---:S 4" i ' --~- 3 II ----S/ ,,l.,, ~ cl 3 1 l I (Z) lb SCALE: 3/4" • 3/4" • 2" ; 4" t I 32 46 1 /16" 1'-0" C I cu i [(; Is-I :Ll7 ' FORREST K. HAAG, ASLA, INC. LANDSCAPE ' ' I / ' / PLAN SHEET KEY "AS-BUILT" ARCHITECTURE LAND l PLANNING 1254 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 [i?J.~aja=.z.~'\£'if-~APPROVED FOR PLANTING AND P: (949) 376-9066 F: (949) 376-9067 c.r~f~§?'i''• DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. TITLE _______ _ REVIEWED BY: INSPECTOR DATE DATE ~ ,._ CITY OF CARLSBAD ~ 31 DATE INITIAL DATE INITIAL OTHER APPROVAL CllY APPROVAL PLANNING DEPARTMENT IRRIGATION PLAN BALLROOM LA COSTA RESORT & SPA CARLSBAD CALIFORNIA ASSISTANT OWN BY: __ _ PROJECT NO. CHKD BY: __ _ RVWD BY: CUP258(C) DRAWING NO. 402-2P =:::::: ~-J , \ ! I \ I ;, 4" = ! ! I -\ , ! iii =\ I , ' '1 I = 3 4" ', = \ I 3/4" i ' 'I ' I = ,, !I, = I -.............. / I / I I I ' ! 3/4' I / ! I I \ \ ::::::- 1/4" 1" - -...!..... --.... " ,, ', \ -· ',V 0 -\ ---.;. ! , ', -- I / I 1' / // !' I 1~i /11 I i ,i / I\ / l \ l I i MATCH!i'.INE _sEE_sH_EE_T 1_9 L _____ ..,.__ I -----, / J_ ;·'/ ------""-!.rJ =:::::: =:::::: =:::::: " 3 4" ,, --- ----.' ------- ' ----------' ----------:::::::: I ' -----, I --,---r-, I ' \\f, i 0 I \ ,,1 I \2 I I \ I I \ I I \ I I -- ' " 5/4" ---.... ---.... .........__ ~-----.:_--------------------------------------------- CAM IN~ =:::::: ,,s'll-- \ I -~ \ I ' I I ! 1 j i ' 3/4' i ' • I , I ~ I ! = Ii= -----~/ -I , '/ _, I, i, \ -I ,, I ~ , 3/4" -1 I 1/ / /4" ' -/ -----" / ----~--I _, - 3/4 ------ 1 I r lb SCALE: I ,--~---! ' ' .... I I .... ..J I 3/4' FORREST K. HAAG, ASLA, INC. LANDSCAPE ARCHITECTURE LANO PLANNING 1254 N. COAST HIGHWAY LAGUNA BEACH, CA 92651 P: (949) 376-9066 F: (949) 376-9067 -t*-t~;'y;!t(i,y .-~ I i ; I --r- . ··-!. : ii.'· -. . I 7 .... ~ ~ ~ I APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. PLAN SHEET KEY "AS-BUILT" TITLE ________ _ DATE REVIEWED BY: INSPECTOR DATE 1------t--+------------+---+---l--~e-------1 ~ CITY OF CARLSBAD Is~ ;::~==·::::'...: l===PL:::A=N=N=IN=G==D=EP=A=R=TM:::::::E=N=T==='--'===~ j I 32 48 1 /16" 1 '-0" DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL IRRIGATION PLAN BALLROOM LA COSTA RESORT & SPA CARLSBAD CALIFORNIA ASSISTANT PLANNING DIRECTOR DWN BY: __ _ PROJECT NO. CHKD BY: __ _ RVWD BY: CUP258(C) DRAWING NO. 4O2-2P 12' MIN. 1• r-r----------,--.,,..., LEGEND l CUIO!B, SIDEWALK. ETC. 2. ROUND PLASTIC VALVE SOX W/ LOCKING TOP (I AeEI er, MASTER VAL YEJ SET I' AeoYEFINISl-l~EIN PLANTING Ai.EAS ONLY. 3. FINISI-I ~- 4. COMMON AND CONTROL Wll"£5 TO CONTl'lOLLER LOCATION. 5. MASTER VALVE (f<EFER TO LEGEND!. 6. PVC MAINLINE. 1. 2 CF. PEA er.RAVEL SLIMF. 5. FLANCiED COl+IECTIONS (TYF. 2 PLACES!. NOTES • ALL VALVES TO 6E INSTALLED H PRESS. REGULATING MASTER VALVE I J 0 □---+---+-----+1-l • LEGEND I. WALL MOI.M' CONTROLLER f<EFER TO FLAN FOR SIZE AND LOCATION 2. 12<Z> VOLT ON-OFF SWITCH 3. 3' DIA. CONDUIT FOR coNTROL WIRES (GREY CONDUIT ONLY A60YE ~E!. FASTEN 5ECUREL Y TO WALL. 4. 120 VAC. CONDUIT. FASTEN SECURELY To WALL. 5. VANDAL PROOF, LOCl<ING STAINLESS STEEL ENCLOSURE NOTE, l ALL WIRES TO 6E INSTALLED FER LOCAL CODE. 2. RAIN61RD 'RAINCHECI<' AUTOMATIC 51-!UT-OFF DEVICE TO 6E INSTALLED FER MANLFACTURER'S SPECIFICATIONS WALL MOUNT CONTROLLER -"' -Q'..,.__,,,. N d+----'--+-~1--~ l 1-¼RDSCAFE 5UJ'iFACE. 2. CLEAN eACKFILL AS REQUIRED, TO 6E SET IN 6' LIFTS. REFER TO SPECIFICATIONS FOR SPECIFIC MATERIAL AND CCMFACTION REQUIREMENTS. ;;. CLEAN SAND. 4. LATERAL LINE WITI-I SLEEVE. "· FRE66l.lRE MAINLINE WITI-I 61.EEYE. 6. CONTROL WIRE6 • COMFLITER 1-!ARDWARE Wll'!E SLEEVE. SLEEVING b' NOTES, ALL 6LEEYE5 TO 6E FYC. 6CI-I. Ile> AND TWO AND ONE 1-!ALF (2½! Tn-E6 Tl-IE DIA. OF Tl-IE WOl'il<INS FIFE. CLEAN !>ACKFILL MAY 6E 5U65TITUTED FOR SAND UNDER WALl<S. E F G l FIN15Mc.RADE 2. I<!)' DIA. Fi?OI.ND VALYE eox WITH LOCl<:INS LID 'Ill<!> HAN.FACTUFi!ED 6Y CAl'l,SON INDU5m!E5. MAl'!<.ED 'QC.' CNCOYER 3. QUICK COUFI.INS VALYE 4. PVC 6CH Ile> 1'!ISEf'! 5. {2! PVC STREET ELLS 6. PVC 6CH Ile> NIFFI.E 1. PVC TEE a PVC 6CH 411> ELL 9. PVC MAIN LINE lfD. OE CUBIC FT. 0::: 34' Ciii1JSI-ED i.ocK NOTE, INSTALL 6' f'RCM NEA!sE5T ADJACENT FAYED A1'!EA QUICK COUPLING VALVE - - - --111= m m-m r l FINISI-I ~E 2. PLASTIC VALVE SOX WITH LOCl<lNC!, LID MARl<ED 'G.V.' 3. GATE VALVE NOTE, I. INST ALL VAL YE eox 5UCH Tl-¼T 4. ONE CU61C FT. OF 3/4' CRUSI-IED Roel< 5. PVC MAIN LINE 6. 6RASSUNION 1. PVC SCH El€> MALE ADAPTOR (2 l'!EGlUIREDJ &. PVC SI-IC El€> NIPPLE GATE VALVE r-- 1 I NOTES, Tl-IE TOP OF Tl-IE COYER 15 2' A60YE FINISI-I GRADE IN G!'lOUND COYER AREAS AND FLUSI-I WITI-I TU1'lFAREAS 2. ALL GATE VALVES OYER 2' IN SIZE 51-!ALL 6E eox 1-¼NDLE GATE VAL YES LEGEND FINISl-l~E 2 RIP DEVICE SEE LEGEND FOR SPECIFICATION ~ 6RA55 6ALL VALVE TYF. 4 EIRA55 NIPPLES MIN. 4' TYF. :> EIRA55 ELL. 4 REQUIRED lb 6ACKFLOW ENCLOSURE FER LEGEND 7 PRESSURE REGULATOR IF SPECIFIED 6 6RA55 UNION, 2 REQUIRED 9 6RA55 RISERS LEN<l,Ti-1 AS REG. le> PVC MAINLINE TO MASTER VAL YE II SCH El€> PVC FEMALE ADAPTER 12 SCH El€> PVC NIPPLE 6' MIN. 1~ FYC MAINLINE • eACKFLOW 51-iALL 6E TESTED e;y A CERTIFIED TESTER AND RE5UL TS MUST l3E GIVEN TO Tl-IE OWNER AND Tl-IE WATER DISTRICT FER CITY SPECIFICATIONS. • FIFE 13ETU.IEEN Tl-IE: ME I ER AND 6ACfCl'LOW 51-iALL 6E '6CI-IEDULE K 1-!Ali!D COFFER' FER CITY SPECIFICATIONS. • INST ALL FER C.MIIJ.D. STANDARD DRAWING. • W-20 BACKFLOW PREVENTOR B C D 2 ~ 4' MIN. I, f 1 111 11 i II I I 111 11 i I 11 i 1111 " 6 • LI 11111 i I I I I 111111 11 i' I II I " Ill -Ill -Ill . . 6 1= - 111 t I: --£! 1 I. FINISI-I~ 6. PVC LATERAL LINE 2. CURB, WALi< OR FOLNDATION 3. FOF-IJF SFRAY I-IEAD 4. PVC SCH El€> RISER 5. PVC SCH El€> NIPPLE 1. TWO PVC STREET ELLS 6. PVC SCH ~ ELL 9. FVCTEE POP-UP SPRAY HEAD . . .. . . • 4 LEGEND l CUIO!B, SIDEWALK. ETC. 6. PVC T x T MARLEX STREET ELL. 2. FINISI-I~. ,. SCHEDULE El€> PVC NIPPLE - 3. FOF-IJF ROTOR 1-!EAD WITI-I MIN. 10' LONG. ANTI-DRAIN VALVE. SET TOP 6. 5CI-I. El€> PVC TxT MARLEX OF 1-!EAD 1n• A60YE ~-STREET ELL. 4. 5CI-I. El€> PVC NIPPLE ... SCH. W PVC SxSxT TEE . HIN. 2' LONG. &. 5CI-I. El€> PVC TxT ELL. 10. LATERAL LINE FIFE AND FITTING. POP-UP ROTOR HEAD 2 ~~--ril-~~71:t-1i~~L~il*[ LEGEND I. FINISI-I ~ 2. PLASTIC VALVE eox WITI-I LOCl<ING. COYER. MARI< 'RC.V.' AND STATloN NO. oN COYl:Ft LOCATE IN 51-1FW6 13ED. 3. SNAF-TITE ELECTRICAL CONNECTORS 4. PVC SCH El€> MALE ADAPTOR (2 REQUIRED! "· l"VC SCI-I w "'- CONTROL VALVE b 1 6. PVC TEE 1. PVC MAIN LINE 13. ONE CU61C FT. OF ¾" CRU5!-IED Roel< 2 4 ~ 9 F M I. EXIST!Na. 2' WATER METER-12<Z> FSI 2. GATE VAL YE 3. 6ACKFLOW FREYENTOR 4. FRE55URE REGULAT!Na. MASTER VALVE 5. !'LOW 5EN50R 6. GlUICI< COIJFLER 1. FRE55URE MAINLINE LEADING TO Fl'iOF05ED IRRIGATION SYSTEM REFER TO FLAN FOR co;;a;IECT SIZING 6. PRESSURE MAINLINE LEADING TO EXISTING, WATE!t SYSTEMS 9. POINT OF CONNECTION TO EXIST!Na. &' MAIN 1 NOTE, ALL EGlUIFMENT TO 6E INSTALLED FER CITY OF CARL5e <ID LANDSCAPE MANUAL. A POINT OF CONNECTION FORR£5T K. HAAG, A5LA. INC. LANO SCAPE ARCHITECTURE LANO PLANNING l2!i4 N. COAST fl/GI/WAY LAGUNA BEACH, CA 9267 I f;f-:;;;~§:,,.....S2~:;\t-APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. "AS-BUILT" TI1LE _______ _ DATE REVIEWED BY: INSPECTOR DATE t-------;---+------------+---+---+---+----1 ~ CITY OF CARLSBAD I SH;~ ~ PLANNING DEPARTMENT _.,....,,, ;::::==:'....:::::========='....::::====: DAlE INITIAL DAlE INITIAL DA 1E INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL aTY APPROVAL IRRIGATION 0£TAIL5 BALLROOM LA COSTA RESORT & SPA CARLSBAD CALIFORNIA ASSISTANT PLANNING DIRECTOR DWN BY: __ _ PROJECT NO. CHKD BY: __ _ RVWD BY: CUP258(C) DRAWING NO. 4O2-2P IRRIGATION SPECIFICATIONS PART 1 -GENERAL 1.01 DESCRIPTION A. Scope of Work: Provide all labor, materials, transportation, and services necessary to furnish and install the Irrigation System as shown on the Drawings and described herein. B. Standards: All work and materials shall comply with governing codes, safety orders, standards, and regulations, and meet the minimum requirements of the Standard Specifications For Public Works Construction (Green Book) latest edition. 1.02 QUALITY ASSURANCE & REQUIREMENTS A. Permits and Fees: The Contractor shall obtain and pay for any and all permits and all observations as required. B. Manufacturer's Directions: Manufacturer's directions and detailed drawings shall be followed in all cases where the manufacturers of articles used in this Contract furnish directions covering points not shown in the Drawings and Specifications. C. Ordinances and Regulations: All local, municipal and state laws, and rules and regulations governing or relating to any portion of this work are hereby incorporated into and made a part of these Specifications, and thei'. provisio,:is sh_all be carried out by the Contractor. Anything contmned in these Specifications shall not be construed to conflict with any of the above rules, regulations, or requirements of the same. However, when these Specifications and Drawings call for or describe materials, workmanship, or construction of a better quality, higher standard, or larger size than is required by the above rules and regulations, the provisions of these Specifications and Drawings shall take precedence .. D. Explanation of Drawings: 1. Due to the Scale of the Drawings, it is not possible to indicate all offsets, fitting, sleeves, etc., which may be required. The Contractor shall carefully investigate the structural and finished conditions affecting all of his work and plan his work accordingly, furnished such fittings, etc., as may be required to meet such conditions. Drawings are generally diagrammatic and indicative of the work to be installed. The work shall be installed in such a manner as to avoid conflicts between the irrigation system, planting and architectural features. 2. All work called for on the Drawings by notes or details shall be furnished and installed whether or not specifically mentioned in the specifications. 3. The Contractor shall not willfully install the irrigation system as shown on the Drawings when it is obvious in the field that obstructions, grade differences, or discrepancies in area dimensions exist that might not have been considered in engineering. Such obstructions or differences shall be brought to the attention of the Landscape Architect. In the event this notification is not performed, the Contractor shall assume full responsibility for any revision necessary. 1.03 SUBMITTALS A. Material list: 1. The Contractor shall furnish the articles, equipment, materials, or processes specified by name in the Drawings and Specifications. No substitution will be allowed without prior written approval by the City of Carlsbad. 2. Complete material list shall be submitted prior to performing any work. Material list shall include the manufacturer, model number, and description of all materials and equipment to be used. Although manufacturer and other information may be different, the following is a guide to proper submittal format: Item No. Qescrig:tion Manufacturer Model No. 1 2 3 4 B. Backflaw Preventer Febca 825Y Automatic Controller Calsense ETI-DTR2 Moster Valve Clayval 136ACSKC-24V Etc. Etc. Etc. Irrigation submittal must be specific and complete. All items must by listed and should include solvent, primer, wire, connectors, valve, boxes, etc. No copies of manufacturer's literature (catalog cuts) ore required as submittal information. 3. The Contractor may submit substitutions for equipment and materials listed on the Drawings by following procedures as outlined in Section 1.05 of the Irrigation Specifications. 4. Equipment or materials installed or furnished without prior approval of the City of Carlsbad may be rejected and the Contractor may be required to remove such materials from the site at his own expense. 5. Approval of any item, alternative or substitute indicates only that the product or products apparently meet the requirements of the Drawings and Specifications on the basis of the information or samples submitted. 6. Manufacturer's warranties shall not relieve the Contractor of his liability under the guarantee. Such warranties shall only supplement the guarantee. RECORD DRAWINGS: 1. The Contractor shall provide and keep up-to-date a complete record set of blueline diazo prints which shall be corrected daily, showing every change from the original Drawings and Specifications and the exact installed locations, sizes, and kinds of equipment. Prints for this purpose may be obtained from the City of Carlsbad at cost. This set of drawings shall be kept on the site and shall be used only as a record set. C. D. E. 2. 3. The Contractor shall make neat and legible notations on the record drawing progress sheets daily as the work proceeds, showing the work as actually installed. For example, should a piece of equipment be installed in a location that does not match the plan, the Contractor must indicate that equipment has been relocated in a graphic manner so as to match the original symbols as indicated in the irrigation legend. The relocated equipment and dimensions will then be transferred to the original record drawing plan at the proper time. Before the date of the final observation, the Landscape Architect shall transfer all information from the • record drawing" prints to city mylar or a new CAD mylar base sheet. Arrangements shall be made through the city for obtaining city mylar. The dimensions shall be made as to be easily readable even on the final controller chart (see S<jction C). The mylar • record drawing" plan shall be I submitted to the City of Carlsbad for approval prior to the completion of the controller chart. 4. The Contractor shall dimension from two (2) permanent paints of reference, such as building corners, sidewalk edges, road intersections, etc., the location of the following items: a. Connection to existing water lines. b. Connection to existing electrical power. c. Gate valves. d. Routing of sprinkler pressure lines ( dimension max. 100' along routing) including all changes of direction. e. Sprinkler control valves. f. Routing of control wiring and locations of all splice boxes. g. Quick coupling valves. h. Stub-outs for future connections. i. Other related equipment as directed by the City of Carlsbad. 5. On or before the date of the final field observation, the landscape Architect shall deliver the revised city mylars (or new mylars) to the City of Carlsbad. Delivery of the mylars will not relieve the Contractor of the responsibility of furnishing required information that may be omitted from the prints. Controller Charts: 1. As-builts drawings shall be approved by the Owner before controller charts are prepared. 2. Provide one controller chart for each controller sequence. 3. The chart shall show the area controlled by the automatic controller and shall be the maximum size which the controller door will allow. 4. The chart is to be a reduced drawing of the actual installed system. However, in the event the controller sequence is not legible when the drawing is reduced, it shall be enlarged to a size that will be readable when reduced. 5. The chart shall be a black line or blueline ozalid print and a different color shall be used to indicate the area of coverage for each station. 6. When completed and approved, the chart shall be hermetically sealed between two pieces of plastic, each piece being a minimum 20 mils. 7. These charts shall be completed and approved prior to the final field observation of the irrigation system. Operation and Maintenance Manuals: 1. Prepare and deliver ta the Owner within ten calendar days prior to completion of construction, two hard-cover, three ring binders containing the following information: a. Index sheet which states Contractor's name, address, and telephone number, and which lists each installed equipment and material item including names and addresses of manufactures loco! representatives. b. Catalog and parts sheets on every material and equipment item installed under this Contract. c. Guarantee statement. d. Complete operating and maintenance instructions on all major equipment. 2. In addition to the above mentioned maintenance manuals, provide the Owner's maintenance personnel with instructions for major equipment and show evidence in writing to the Owner at the conclusion of the project that this service has been rendered. Equipment to be Furnished: 1. Supply as a port of this contract the following tools: a. Two (2) sets of special tools required for removing, disassembling and adjusting each type of sprinkler and valve supplied on this project. b. Two (2) four-foot valve keys for operation of gate valves. c. Two (2) keys for each automatic controller. d. One (1) quick coupler key and matching hose swivel for every five (5) or fraction thereof of each type of quick coupling valve installed. 2. The above mentioned equipment shall be turned over to the Owner at the conclusion of the project. Before final observation can occur, evidence that the Owner has received material must be shown to the Owner. 1.04 1.05 PART 2 2.01 PRODUCT DELIVERY, STORAGE AND HANDLING A. Handling of PVC pipe and fittings: The Contractor is cautioned to exercise care in handling, loading, unloading, and storing PVC pipe and fittings. All PVC pipe shall be transported in a vehicle which allows the length of pipe to lie flat so as not to subject it to under bending or a concentrated external load at any point. Any section of pipe that has been dented or damaged will be discarded, and if installed, shall be replaced with new piping. SUBSTITUTIONS A. If the Contractor wishes to substitute any equipment or materials for the equipment or materials listed on the Drawings and Specifications, he may do so by providing the following information to the City of Carlsbad for approval: 1. Provide a statement indicating the reason for making the substitution. Use a separate sheet of paper for each item to be submitted. 2. Provide descriptive catalog literature, performance charts and flow charts far each item to be substituted. 3. Provide the amount of cost savings if the substituted item is approved. B. The City of Carlsbad and the Owner shall have the responsibility in accepting or rejecting any submittal item as an approved equal to the equipment and materials listed on the Drawings and Specifications. GUARANTEE A. The guarantee for the irrigation system shall be made in accordance with the attached form. The General Conditions and Supplementary Conditions of these Specifications shall be flied with the Owner prior ta acceptance of the irrigation system. B. A copy of the Guarantee form shall be included in the operations and maintenance manual. C. The guarantee form shall be re-typed onto the Contractor's letterhead and shall contain the following information: GUARANTEE FOR IRRIGATION SYSTEM We hereby guarantee that the irrigation system we have furnished and installed is free from defects in materials and workmanship, and the work has been completed in accordance with the Drawings and Specifications. ordinary wear and tear. unusual abuse, or neglect excepted. We agree ta repair or replace any defects in material or workmanship which may develop during the period of one year from date of acceptance and also to repair or replace any damage resulting from the repairing or replacing of such defects at no additional costs to the Owner. We shall make such repairs or replacements within a reasonable time, as determined by the Owner, ofter receipt of written notice. In the event of our failure to make such repairs or replacements within a reasonable time after receipt of written notice from the Owner, we authorize the Owner to proceed to have said repairs or replacements made at our expense and we will pay the costs and charges therefore upon demand. PROJECT: ____________________ _ LOCATION: ____________________ _ SIGNED: _____________________ _ ADDRESSED: PHONE: _______ _ DATE OF ACCEPTANCE: ___ _ PRODUCTS MATERIALS A. General: drawings, Use only new materials of brands and types noted on specified herein, or approved equals. B. PVC Pressure Main Line Pipe and Fittings: 1. Pressure main line piping for sizes 2" and larger shall be PVC Class 315 with solvent-welded joints. 2. Class 315 pipe shall be made from an NSF approved Type 1, Grade 1, PVC compound conforming ta ASTM resin specification D1784. All pipe must meet requirements as set forth in Federal Specification PS-22-70, with an appropriate standard dimension (S.D.R.) (Solvent-weld Pipe). 3. Pressure main line piping for sizes 1-1/2" and smaller shall be PVC Schedule 40 with solvent welded joints. 4. Schedule 40 pipe shall be made from NSF approved Type 1, Grade 1 PVC compound conforming to ASTM resin specification D1785. All pipe must meet requirements as set forth in Federal Specification PS-21-70. 5. PVC solvent-weld fittings shall be Schedule 40, 11-1 NSF approved conforming to ASTM test procedure D2466. 6. Solvent cement and primer for PVC solvent-weld pipe and fittings shall be of type and installation methods prescribed by the manufacturer. 7. All PVC pipe must bear the following markings: a. Manufacturer's name b. Nominal pipe size c. Schedule or class d. Pressure rating in P.S.I. e. NSF (National Sanitation Foundation) approval f. Date of extrusion 8. C. E. F. G. H. All fittings shall bear the manufacturer's name or trademark, material designation, size, applicable I.P.S. schedule and NSF seal of approval. PVC Non-Pressure lateral Line Piping: 1. Non-pressure buried lateral line piping shall be PVC Schedule 40 with solvent-weld joints when installed in planting areas. 2. Non-pressure lateral line piping installed under paved areas shall be PVC Schedule 40 with solvent welded joints. 3. Pipe shall be mode from NSF approved, Type I, Grode 11 PVC compound conforming to ASTM resin specification 01784. All pipe must meet requirements set forth in Federal Specification PS-22-70 with an appropriate standard dimension ratio. 4. Except as noted in paragraphs 1, 2, and 3 of this section (2.01 B), all requirements for non-pressure lateral line pipe and fittings shall be the same as for solvent-weld pressure main line pipe and fittings as set forth in section 2.01 B of the Specifications. Valves: 1. Ball Valves (1-1/2" and smaller) a. Ball valves shall be a 125 lb SWP bronze valve with screw-in bonnet, nonrising stem, and solid wedge disc. with a stainless steel handle. b. Ball valves shall be similar to those manufactured by Nibco or approved equal. c. All Ball valves shall be installed per detail. 2. Gate Valve (2" and larger) a. Resilient Wedge Gate valves shall be epoxy coated cast iron and equipped with o 2• operating nut. b. Resilient Wedge Gate valves shall be No. 403 RT-RW as supplied by Watts or approved equal. c. All Resilient Wedge Gate valves shall be installed per detail. Quick Coupling Valves: 1. Quick coupling valves shall have a brass, two-piece body designed for working pressure of 150 P.S.I. 2. Quick coupling valve shall be operable with a quick coupler key. Key size and type shall be as shown on the Drawings. Check Valves: 1. Swing check valves 2• and smaller shall be 200 pound W.O.G. bronze construction with replaceable composition, neoprene, or rubber disc and shall meet or exceed Federal Specification WW-V--510, Class A, Type IV. 2. Anti-drain valves shall be of heavy duty virgin PVC construction with F.I.P. thread inlet and outlet. Internal parts shall be stainless steel and neoprene. Anti-drain valve shall be field adjustable against drawout from 5 to 40 feet of head. Anti-drain valve shall be similar to the Vol con "ADV" or approved equal. Control Wiring: 1. Except as noted otherwise, connections between the automatic controllers and the electric control valves shall be made with direct burial copper wire AWG-U.F. 600 volt. Control wiring installed in control wire conduit within structure shall be made with AWG-TW solid copper wire. Pilot wires shall be a different color wire for each automatic controller. Common wires shall be white with a different color stripe far each automatic controller. Install in accordance with valve manufacturer's specifications and wire chart. In no case shall wire size be less than #14. 2. Wiring shall occupy the same trench and shall be installed along the same route as pressure supply or lateral lines wherever possible. 3. Where more than one (1) wire is placed in a trench, the wiring shall be taped together at intervals of fifteen (15) feet. I. J. K. l. 4. An expansion curl shall be provided within three (3) feet of each wire connection. Expansion curl shall be of sufficient length at each splice connection at each electric control valve, so that in case of repair, the valve bonnet may be brought to the surface without disconnecting the control wires. Control wires shall be laid loosely in trench without stress or stretching wire conductors. 5. All splices shall be made with Scotch-Lok #3576 Connector Sealing Packs, Rainbird Snap-Tile wire connectors., or approved equal. Make only one splice with each connector sealing pack. 6. Field splices between the automatic controller and electric control valves will not be allowed without prior approval of the City of Orange. Electric Control Valves: 1. All electric control valves shall be the same size and type shown on the Drawings. 2. All electric control valves shall have a manual flow adjustment. 3. Provide and install one control valve box for each electric control valve. Sprinkler Heads: 1. All sprinkler heads shall be of the same size, type, and deliver the same rate of precipitation with the diameter (or radius) of throw, pressure, and discharge as shown on the Drawings and/or specified in these special provisions. 2. Spray heads shall have a screw adjustment. 3. Riser units shall be fabricated in accordance with the details shown on the drawings. 4. Riser nipples for all sprinkler heads shall be the same size as the riser opening in the sprinkler body. 5. All sprinkler heads of the same type shall be the same manufacturer. Sleeving: 1. Sleeving under vehicle hardscape or paved areas for mainline, laterals and control wiring shall be SCH 80 P.V.C and buried 30" below grade. 2. Sleeving under pedestrian hordscape or paved areas for lateral lines shall be SCH 40 P. V.C and buried 12" below grade. 3. Sleeving under pedestrian hardscape or paved areas for mainline and control wires shall be SCH 40 P.V.C and buried 18" below grade. Miscellaneous Irrigation Equipment: 1. Refer to the Irrigation Plans for sizes and types of miscellaneous irrigation equipment. 2. All miscellaneous irrigation equipment shall be as specified or approved equal. M. Potable Control Valve Boxes: 1. Use 10• x 10-3/4" round box for all gate valves. Carson Industries #910-12B with green bolt-down cover or approved equal. Extension sleeve shall be PVC with minimum size of six (6) inches. 2. Use 9-1/2" x 16" x 11" rectangular box for all electric control valves. Carson Industries # 1419-12B with green bolt-down cover or approved equal. 3. Use 6" diameter x 8-3/4" deep round plastic valve box for all quick coupling valves. Carson Industries # 608-12 with green flex-lock cover or approved equal. 4. Use 9-1/2" x 16" x 11• rectangular box for all electric control valves installed within on-grade landscaped areas. Carson Industries # 1419-12B with green bolt-down cover or approved equal. 5. Use 10• x 10-1/4" round box for all quick coupling valves installed within on-structure landscaped areas. Corson Industries No. 910-12B with green bolt-down cover or approved equal. APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. "AS-BUILT" TITLE ________ _ REVIEWED BY: INSPECTOR DATE DATE 1-----1-----+-------------+---+---;-----t-----i I s~;J CITY OF CARLSBAD Is~ PLANNING DEPARTMENT _,..., ~::::::::::':=-==========:.::::~:::::; DATE INITIAL DATE INITIAL DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL QTY APPROVAL IRRIGATION 5P£CIFICATION5 BALLROOM LA COSTA RESORT & SPA CARLSBAD. CALIFORNIA AF t ~OVE-B--., A / I _,ck.2:!".1__,✓~ IJ~-u _____ ....,.3-0J ASSISTANT PLANNING DIRECTOR DATE OWN BY: CHKD BY: __ _ RVWD BY: PROJECT NO. CUP258(C) DRAWING NO. 402-2P IRRIGATION SPECIFICATIONS (continued) N. Backflow Prevention Units: 1. Backflow prevention unit shall be of size and type indicated on the irrigation drawings. Install bacl<flow prevention units in accordance with the Drawings. 2. Wye strainers at backflow prevention units shall have a 3. bronzed screwed boy with 60 mesh monel screen and shall be similar to Bailey #1 OOB or approved equal. All pressure main line piping between the point of connection and the backflow preventer shall be installed as required by local code. The Contractor shall verify with the local governing body as to material type and installation procedures prior to start of construction. Submit shop drawing for approval. 0. Automatic Controller. 1. Automatic controller(s) shall be of size and type shown on the Drawings. 2. Final location of automatic controller(s) shall be approved by the Landscape Architect and Owner. 3. Unless otherwise noted on the Drawings, the 120 volt electrical power to each automatic controller location is to be furnished by others. The final electrical hook-up shall be the responsibility of the Contractor. P. Vandal Resistant Controller Enclosure: 1. Controller enclosure shall be of size and type shown on the Irrigation Drawings and Irrigation Detail sheet. 2. A backboard shall be secured to the controller enclosure housing to provide a base for mounting the automatic sprinkler controller and terminal strip. PART 3 -EXECUTION 3.01 OBSERVATION OF SITE CONDITIONS A. All scaled dimensions are approximate. The Contractor shall check and verify all size dimensions and receive approval from the City of Carlsbad prior ta proceeding with work under this Section. B. Exercise extreme care in excavating and working near existing utilities. The Contractor shall be responsible for damages to utilities which are caused by his operations or neglect. Check existing utilities drawings for existing utility locations. C. Coordinate installation of sprinkler materials including pipe, so there shall be no interference with utilities or other construction or difficulty in planting trees, shrubs, and ground covers. D. The Contractor shall carefully check all grades to satisfy himself that he may safely proceed before starting work on the irrigation system. 3.02 A. PREPARATION Physical layout: B. C. 3.03 A. 1. Prior to installation, the Contractor shall stoke out all pressure supply lines, routing and location of sprinkler heads. 2. All layout shall be approved by the City of Carlsbad. prior to installation. Water Supply: 1. 2. The irrigation system shall be connected to water supply point(s) of connection as indicated on the Drawings. Connections shall be made at the approximate location(s) shown on the Drawings. The Contractor is responsible for minor changes caused by actual site conditions. Electrical Supply: 1. Electrical connections for any and all automatic controllers shall be made to electrical point(s) of connection as indicated on the Drawings. 2. Connections shall be made at the approximate location(s) shown on the Drawings. The Contractor is responsible for minor changes cause by actual site conditions. INSTALLATION Trenching: 1. 2. 3. 4. 5. 6. Dig trenches straight and support pipe continuously on bottom of trench. Lay pipe to an even grade. Trenching excavation shall follow layout indicated on the Drawings and as noted. Provide for a minimum of thirty (30) inches cover for for all irrigation lines installed under vehicle paving. Provide for a minimum of twenty-four (24) inches cover for all pressure supply lines of three (3) inches or larger in diameter. Provide for a minimum of eighteen (18) inches cover for all pressure supply lines of two and one half (2½") inches or smaller Provide for a minimum of twelve (12) inches for all non- pressure lines. Provide for a minimum cover of eighteen (18) inches for all control wiring. D. E. B. Backfilling: 1. The trenches shall not be backfilled until all required tests ore performed. Trenches shall be carefully backfilled with the excavated materials approved for backfilling, consisting of earth, loam, sandy clay, sand, or other approved materials, free from large clods of earth or stones. Backfill shall be mechanically compacted in landscaped areas to a dry density equal to adjacent undisturbed soil in planting areas. Backfill will conform to adjacent grades without dips, sunken areas, humps or other surface irregularities. 2. A fine granular material backfill will be initially placed on all lines. No foreign matter larger than one- half (1 /2) inch in size will be permitted in the initial backfill. 3. Flooding of trenches will not be permitted. 4. If settlement occurs and subsequent adjustments in pipe, valves, sprinkler heads, lawn, planting, or other construction are necessary, the Contractor shall make all required adjustments without cost to the Owner. C. Trenching and Backfill Under Paving: 1. Trenches located under areas where paving, asphaltic concrete, or concrete will be installed, shall be backfilled with sand (a layer four ( 4) inches below the pipe and six (6) inches above the pipe) and compacted in layers to 95% compaction, using manual or mechanical tamping devices. Trenches for piping shall be compacted to equal the compaction of the existing adjacent undisturbed soil and shall be left in a firm unyielding condition. All trenches shall be left flush with the adjoining grade. The Contractor shall set in place, cap and pressure test all piping under paving prior to the paving work. 2. Generally, piping under existing walks is done by jacking, boring, or hydraulic driving, but where any cutting or breaking of sidewalks and/or concrete is necessary, it shall be done and replaced by the Contractor as a part of the Contract cost. Permission to cut or break sidewalks and/or concrete shall be obtained from the Owner. No hydraulic driving will be permitted under concrete paving. Assemblies: 1. Routing of sprinkler irrigation lines as indicated on the Drawings is diagrammatic. Install lines (and various assemblies) in such a manner as to conform with the details in the Drawings. 2. 3. Install NO multiple assemblies in plastic lines. Provide each assembly with its own outlet. Install all assemblies specified herein in accordance with respective detail. In absence of detail drawings or Specifications pertaining to specific items required to complete work, perform such work in accordance with best standard practice with prior approval of City of Carlsbad. 4. PVC pipe and fittings shall be thoroughly cleaned of dirt, dust, and moisture before installation. Installation and solvent welding methods shall be as recommended by the pipe and fitting manufacturer. 5. On PVC to metal connections, the Contractor shall work the metal connections first. Teflon tape or approved equal, shall be used on all threaded PVC to PVC, and on all threaded PVC to metal joints. Light wrench pressure is all that is required. Where threaded PVC connections are required, use threaded PVC adapters into which the pipe may be solvent welded. Line Clearance: F. G. H. I. 1. All lines shall hove a minimum clearance of six (6) inches from each other and twelve (12) inches from lines of other trades, with the exception of the control wire sleeve(s) which shall be installed adjacent to pressure supply line. Parallel lines shall not be installed directly over one another. Automatic Controller Assembly: Install as per manufacturer's instructions. Remote control valves shall be connected to controller in numerical sequence as shown on the Drawings. High Voltage Wiring for Automatic Controller: 1. 120 volt power connection to the automatic controller shall be provided by the Contractor. 2. All electrical work shall conform to local codes, ordinances, and union authorities having jurisdiction. Remote Control Valves: 1. Install where shown on the Drawings. Where grouped together, allow at least twelve (12) inches between adjacent valve boxes. Install each remote control valve in a separate valve box. Flushing of System: 1. After all new sprinkler pipe lines and risers are in place and connected, all necessary diversion work has been completed, and prior to installation of sprinkler heads, the control valves shall be opened and full head of water used to flush out the system. 2. Sprinkler heads shall be installed only after flushing of the system has been accomplished to the complete satisfaction of the City of Carlsbad. J. Sprinkler Heads: 1. Install the sprinkler heads as designated on the Drawings. Sprinkler heads to be installed in this work shall be equivalent in all respects ta those itemized. 2. Spacing of heads shall not exceed the maximum indicated on the Drawings. In no case shall the spacing exceed the maximum recommended by the manufacturer. 3.04 TEMPORARY REPAIRS The Owner reserves the right to make temporary repairs as necessary to keep the sprinkler system equipment in operating condition. The exercise of this right by the Owner shall not relieve the Contractor of his responsibilities under the terms of the guarantee as herein specified. 3.05 EXISTING TREES 3.06 3.07 Where it is necessary to excavate adjacent to existing trees, the Contractor shall use all possible care to avoid injury to trees and tree roots. Excavation in areas where two (2) inch and larger roots occur shall be done by hand. All roots two (2) inches and larger in diameter, except directly in the path of pipe or conduit, shall be tunneled under and shall be heavily wrapped with burlap to prevent scarring or excessive drying. Where a ditching machine is run close to trees having roots smaller than two (2) inches in diameter, the wall of the trench adjacent to the tree shall be hand trimmed, making clean cuts through. Roots one (1) inch and larger in diameter shall be painted with two coats of Tree Seal, or equal. Trenches adjacent to tree should be closed within twenty-four (24) hours; and where this is not possible, the side of the trench adjacent to the tree shall be kept shaded with burlap or canvas. FIELD QUALITY CONTROL A. Adjustment of the System: 8. 1. The Contractor shall flush and adjust all sprinkler heads for optimum performance and to prevent overspray onto walks, roadways, and buildings as much as possible. 2. If it is determined that adjustments in the irrigation equipment will provide proper and more adequate coverage, the Contractor shall make such adjustments prior to planting. Adjustments may also include changes in nozzle sizes and degrees of arc as required. 3. Lowering raised sprinkler heads by the Contractor shall be accomplished within ten (10) days after notification by the Owner. 4. 5. All sprinkler heads shall be set perpendicular to finished grades unless otherwise designated on the Drawings. Rain Bird EFB-CP valves will be set per manufacturers specification so that each lateral operates at design pressure. Testing of Irrigation System: 1. The Contractor shall request the presence of the City of Carlsbad in writing at least 48 hours in advance of testing. 2. Test all pressure lines under hydrostatic pressure of 150 pounds per square inch and prove watertight. Note: Testing of pressure main lines shall occur prior to installation of the electric control valves. 3. All piping under paved areas shall be tested under hydrostatic pressure of 150 pounds per square inch and proven watertight prior to paving. 4. Sustain pressure in lines for not less than six (6) hours. If leaks develop, replace joints and repeat test until entire system is proven watertight. 5. All hydrostatic tests shall be made only in the presence of the General Contractor and the City. No pipe shall be backfilled until it has been observed, tested, and approved in writing. 6. Furnish necessary force pump and all other test equipment. 7. When the irrigation system is completed, perform a coverage test in the presence of the City of Carlsbad to determine if the water coverage for planting areas is complete and adequate. Furnish all materials and perform all work required to correct any inadequacies of coverage due to deviations from the Drawings, or where the system has been willfully installed as indicated on the Drawings when it is obviously inadequate, without bringing this to the attention of the City of Carlsbad. This test shall be accomplished before any ground cover is planted. 8. Upon completion of each phase of work, the entire system shall be tested and adjusted to meet site requirements. MAINTENANCE A. The entire irrigation system shall be under full automatic operation for a period of seven (7) days prior to any planting. B. The Owner reserves the right to waive or shorten the operation period. 3.08 3.09 3.10 CLEAN-UP Clean-up shall be made as each portion of work progresses. Refuse and excess dirt shall be removed from the site, all walks and paving shall be bloomed or washed down, and any damage sustained on the work of others shall be repaired to its original condition. FINAL SITE OBSERVATION PRIOR TO ACCEPTANCE A. The Contractor shall operate each system in its entirety for the Owner at time of final observation. Any items deemed not acceptable by the Owner. shall be reworked to the complete satisfaction of theOwner. B. The Contractor shall show evidence to the Owner that the Owner has received all accessories, charts, record drawings, and equipment as required before final site observation can occur. SITE OBSERVATION SCHEDULE A. The Contractor shall be responsible for notifying the City of Carlsbad in advance for the following observation 8. C. meetings, according to the time indicated: 1. Pre-Job Conference -7 days 2. Pressure supply line installation -24 hours 3. Lateral line and sprinkler installation -24 hours 4. Automatic controller installation -24 hours 5. Control wire installation -24 hours 6. Pressure supply line and lateral line testing -48 hours 7. Coverage test -48 hours 8. Final observation -7 days When observations have been conducted other than the City of Carlsbad, show evidence in writing of when and by whom these observations were made. No site observations will commence without "As-Built" record drawings. The contractor shall not call for a site visit without "As-Built" record drawings, without completing previously noted corrections, or without preparing the system far said visit. FORREST K. HAAG, ASLA, INC. LAN05CAP£ ARCHITECTURE LAND PLANNING "AS-BUILT" 125"4 N. COAST HIGHWAY LAGUNA BEACH, CA 9265" I PJ949} 376-9066 FJ949) 3Ur'J067 ,-i_f#l!:if:~.k~}}i•:i:•:Si(;.,;fit-'-·<•'.··· APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. TITLE DATE -·c:'"~\:1/i~~t'{½'•1'-'~f-,•,. ,;.,,,, .,, ' ~r\t?;~ry;,;'.';'L·:.:·>~. REVIEWED BY: INSPECTOR DATE ~ CITY OF CARLSBAD SHEETS 1----+----+-----------------1-------,1----+--+----1 ~ PLANNING DEPARTMENT ~ ~==--'==================~~~ IRRIGATION SPECIFICATIONS DATE INITIAL DATE INITIAL DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL BALLROOM LA COSTA RESORT & SPA CARLSBAD. CALIFORNIA ASSISTANT PLANNING DIRECTOR DWN BY: PROJECT NO. CHKD BY: __ _ RVWD BY: CUP258(C) DATE DRAWING NO. 402-2P