HomeMy WebLinkAbout2411 SACADA CIR | 2413 SACADA CIR; ; 82-164; PermitCII z 0 ~ a: ~ u Ill 0
IC
I[
0 u
IC Ill 0 .... 5 ! Ill z ~
z 0 ;::
C CII z Ill Q.
:::E 0 u
CII cc Ill "' a: 0 :I:
O I hereb{ ~,t I am licensed under
provisions o. 9 (commencing with
Section 7000) .,, ~,vision 3 of the Business
and Professions Code, and my license Is In
lull force and effect. L,c No ______ Class _____ _
I hefeby affirm that I wn exempt ltom the. Con-
~~1~!f ,:'= ~ ~.~~ ~;~ county which requires a pe,mit to construct
alter, impt'ove, demolish, or repair any structure,
prior to its issuance also requires the appltcant for such permit to file a signed statement that he is
licensed pursuant 10 the provisions of the Con· tractor's License ~ (Chapter 9 commencing w,th
Section 7000 ot Oiv1st01'l 3 of the Business and Pre>
feutOns Code) or that is exempt thefefrom and the
basis for the alleged exemption. Any violation of
Sectoon 7031.5 by an applicant fo, a permit subjects tne apphcant to a civil penalty of not more than ftve
hundred dollars ($500).
□ I, as owner of Ille property, o, my employees ,.,th wages as their sote compensation, will do the ""°"'· and the structure is not intended Of" ottered for ..ie (Sec. 7044, Business and Protessoons Code:
The Contractor's license Law does not apply to an owner of property who builds or impt"0¥9S thereon
and whO does such work himself Of through his own
employees, prOYided that such 1mp,oveme;its are
not mlende1 Of offered for sale. It, however. the
building or 1mp,ovement ,s sok:I within one yeat of
completion, the owner-builder will have the burden
of p,ov,no that he did not build Of improve for the purpose or sale).
C I. as ownef of the property, am exclusively
contractini with lteensed contractors to construct
the pr01ect (Sec. 7044, Business and Professt0ns Code: The Contractor's license UW Ooes not apply
to an owner of property who builds or improves
~':'~tc!t~ 7i:,c~~~,!~ ~~~t!'~\~:!!:-!
Ltcense law).
□ I am exempt u~ Sec. _____ , B. & P.C.
fo,th1s reason ___________ _
□ I hereby affirm that I halte a cen,heate of consent
to self-insure, or a cert1f1.:.ate of Workers' Compensahon Insurance, or a cenitled CoPy !hereof
];.
(Sec ::~ Labor Code~
PANV ----rl-/\&A-
Copy IS hied with the City
D Certified CoPY ,s hereby fur.ashed
CERTIFICATl OF EXEMPTION FROM WORJ(ERS' COMPENSATION INSURANCE
(This sechon need not be completed 11 the permit
1s tor one hundred dollars ($100) or less)
0 I certify that m the performance of the wOf1t for
which this pemut ,s issued. I shall not employ any
person m any manner so as to t>ecome sob1ect to
the WOtic.ers· Compensahon Uws of ca11torma
NOTICE TO APPLICANT II. after malun~ lhos Cerh•
hcate ot Exemption. you should become sut>,ect t"J
the Workers· Compensation provisions of the Labor
Code. you must forthwith comply with such
provisions or this permit shall be deemed revoked . l • 0 I hereby affirm that 1here ,s a conslruchoh ~ lending agency fo, the perfOfmance of the wont fo,
0 wl'uch lh•S perm11 1s issued (Sec 3097, C1v1I Code) ffi Lender's Name, ___________ _
-' '· e Lende1'f Address __________ _
USE BALL POINT PEN ONLY & PRESS HARD APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.
fl}/) CARI .P BUILDING DEPARTMENT APPLICATION & PERMIT ' I 'I
1200 Elm, ,ad, California 92008 (714) 438-5525 ~
JOB ADDRESS ~ lttc-t::. " cb ls-c_. Q_,.« L-f: A~iT· 1 Di? ;if;;ATIONI BUS~LICENSE # -io~t~rr:1 PERMIT NUMBER
-'24--11-J~ -O-ER'S NAME ;t /"'ti"" ~,. I OWNER'S PHONE PRIME CONTRACTOR CONTRACTORS PHONE t ZONE -~v ,'f lot/-#flt-y f'l:t.-f/~p lh"~ Wi'f-lr "'~II c., .. A $'t ?f ~-IJin'
OWNER'S MAil.iNG ADDRESS CONTRACTOR'S ADORESS LICENSE NO.
PL{;·:, ktf, B6.aG USE CODE
7n-? h,..~:&, C,'f-. ~'{llf A L3t1~Vc,J u-~u.L .J 'f;t()j "?
LOT BLOCK I SUBDIVISION I ASSESSOR PARCEL j· OESIGNER , STATE LICENSE# ST NDARO PLAN#
BUl~is?E l'fD 2/~-l,P-Y
DESCRIPTION OF WO.,, L~.J111~K. -~"' DESIGNER'S AOORESS DESIGNER'S PHONE
c_t\~~~ J\. '"~\ r:~ ------F/P FLR ELEV. NO p:.~ EDU i,, G/22/82757i=! 6686'.6 I ~ ,,.......... OOOT7672 '§?§iii 82 5666~61 J \ •. 1 ""',. • YO NO --' .. -
CENSUS TRACT I GP LAND USE
1
pi07 s CE
I
RES UNITS
1
GRADING ~ERMIT ISSUED I REOEVELOPMENT TYPE OCC LOAO FIRE SPA AREA CONST
y D ND v□ NO YO .t:i Nor Valid Unwss M.chine Certified -
QTY. PLUMBING PERMIT · ISSUE ,7,So QTY. MECHANICAL PERMIT· ISSUE ~o SUMMARY/ACCOUNT NUMBER . ·v "EACH FIXTURE TRAP ldJ. ,,. -i-INSTALL FURN. DUCTS UP TO 100.000 BTU K . -BUILDING PERMIT 01-0M.4220 /~., ~.ln .,_ --E~CH BUILDING SEWER 1;,,.. OVER 100,000 BTU -SIGNPERMI~
, --01-000·4221 -"'1...-~ACH WATER HEATER AND/OR VENT r.-BOILER/COMPRESSOR UP TO 3 HP PLAN CHEC!n?i ~ K, ~1-000·4806 --7.....,. _...EACH GAS SYSTEM 1 TO 4 OUTLETS _;.-BOILER/COMPRESSOR 3-15 HP TOTAL PLUMB'ING 01 ·000·4222 qo, ... T.,,
EACH GAS SYSTEM 5 OR MORE 7.--:. ~ETAL FIREPLACE l,. -ELECTRICAL 01·000·4223 -,r.,_ -
EACH INSTAl .. ALTER, REPAIR WATER PIPE ~' VENT FAN SINGLE DUCT Jo .-MECHANICAL 01 ·000·4224 -i..._, _ ...
EACH VACUUM BREAKER MECH EXHAUST -HOOD/DUCTS MOBILEHOME 01 ·000·4225
WATER SOFTNER RELOCATION OF EA FURNACE/HEATER MOBILEHOME PARK INSP
EACH ROOF DRAIN (INSIDE) SOLAR 01 ·000·4226 .
~ TOTJ;L MECHANICAL STRONG MOTION 65·640·0519 IL/-. L,I
TOTAL PLUMBING I {,fl) J, .-z_"]. -FIRE SPRINKLERS 01 ·000·4227
I PUBLIC FACILITIES FEE 25·000·4933 -QTY_ ELECTRICAL PERMIT· ISSUE :),14 QTY. SOLAR • ISSUE BRIDGE FEE -• 'V NEW CONST EA AMP/SWT /BK R /(X)H-~rn -COLLECTORS SCHOOL FEE • DISTRICT
1 PH 3 PH STORAGE TANKS Carlsbad 65·623·0519 -
EXIST BLOG EA AMP/SWT/BKR ROCK STORAGE Encinitas 65·624·0519 -L--~'L...1 -1 PH 3 PH PUMP San Dieguito 65·625·0519 .,AL,..,_. -
REMODE UAL TEA PER CIRCUIT PLAN CHECK FEE San Marcos 65·626·0519 ,
TEMP POLE 200 AMPS . ' OVER 200 AMPS I I I
TEMP OCCUPANCY (30 DAYS)
TOTAL ELECTRICAL I ~-TOTAL SOLAR TOTAL FEES PAYABL E I ~ft-Kl,,. i, .'
I HAVE CARE~LY EXAMINED THE COMPLETED "APPLICATION AND PERMIT" ANO DO HEREBY Exptrllton Every perm,t ISSued by the Building Olftc,al under the P,OYISlOOI o(thia * AN OSHA PERMIT IS AEQUIAEO FOR EXCAVATIONS OVER
CERTIFY UNO PENAllY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE Code shall expire by lim1t1Uon and become null and void If the bu1ld1ng or work s· O" DEEP AND DEMOUTIOH OR CONSTIIUCTION CJf'
bEcLARATIONS ARE TRUE ANO CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS authonzed by such permll 11 not commenced within 180 day• from the date of such STI!l.lCT\IM:S OYER l STORIES IN HEIGHT permtl o, ti the bu1ldll o, work autho,izad by 11<1ch perm,1 is suspended or ISSUED: TO COMPLY WITH ALL CllY, COUNTY AND STATE LAWS GOVERNING BUILDING CON· abendoned al anv bme a er the work IS commenced for I oenod ol tllO "•u•
STRUCTION, WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND APPLICANT'S SIGNATURE Jf. OWNER□ CONTRACTOR.ii APPR~ ED BV ~ KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS, COSTS AND X ~ ~
EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEOUENCE OF THE ~ BY PHONE 0 -'-• A
... ~ ,. . I t-i-GRANTING OF THIS PERMIT. ,_-;, '-,....,.
INSPECTION TYPE
• FOUNDATION
REINFORCED STEE
MASONRY
GUNITE OR G8OUI
FLOOR & CEILING SUB FRAME
SHEATHING
FRAME
EXTERIOR LATH lNSULATION
INTERIOR LATH & DRYWALL
PLUMBING
SEWER AND BL/CO
PLUMBING UNDERGROUND
PLUMBING TOP OUT
TUB AND !?HOWER PAN
GAS TEST
ELECTRICAL
TEMPORARY POWER
DATE INSPECTOR
FIELD INSPECTION RECORD
REQUIRED SPECIAL INSPECTIONS
INSPECTION
SOILS COMPLIANCE
PRIOR TO
FOUNDATION INSP
STRUCTURAL CONCRETE
OVER 2000 PSI
PRESTRESSED
CONCRETE
POST TENSIONED
CONCRETE
f ,r FIE-LG Vv1£LDING
HIGH STRENGTH
BOLTS
SPECIAL MASONRY
PILES CAISSONS
I REQ IF I INSPECTORS
CHECKED APPROVAL
g;;J. ... I ~'-f ~ '
INSPECTOR'S NOTES
DATE '[),
I 1 .7
. ..... . l
-j
ELECTRIC UNDERGROUND I . I I / , ROUGH ELECTRIC i ", .... ;,_ ~ r--------:_:-'----+-----J------1--__j r---------------,:-::----=-....,....,.-------·--------;c-,-"'--'~___.
ELECTRIC SERVICE j '"
BONDING ~
G. F. I. -SMOKE DETECTOR
MECHANICAL
DUCT & PLEM., REF. PIPING
HEAT -AIR COND. -SOLAR SYSTEMS
VENTILATING SYSTEMS
CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE
ITEMS ABOVE HAVE
JOB SITE FINAL
PLUMBING
ELECTRICAL
MECHANICAL
GAS
BUILDING
SPECIAL CONr·-·,.Ns CERT OF occit -1s_s_u_e_o ____ ..,.,-il,.._1-. -. -,-+-I ----
,, ..,,,... ' ., ' "'· ~
r ~ ' ·. I I I I ----------·------
.....
r
-, . . . _; "-, ]
--------·--'
... '
----0~
City ·Of Carlsbad --120CkELM, CARLSBAD, CA 92008 • TEL. (714) 438-5525
Job
Address
Owner
State Lie.
S. Classif.
Tel. f'.,,.....,
City
Lie. No.
COMPLETE FOR PLAN CHECK ONLY
LEGAL DESCRIPTION
White -Applicant Yellow -File
,i.
Ml~ ~LLANEOUS
REO--IPT ., I
MISCELLA 1EOUS FEE RECEIPT
~ • PLAN CHECI\ l=EE Ol-000-4806
□ VALUATION
□ DEMOLITION
□ HOUSE MOVING
□ PARKS AND RECREATION FEE
□ PUBLIC FACILITIES FEE
□ , SCHOOL FEE · DISTRICT
□ Carlsbad
□ Encinitas
□ San Diego
□ San Marcos
□---=-~-----"'--....::_:_;.__---,.:::__,.-----+---'-----I
[J __ ...,.._,.....c...-,----,'-----,,,.-..:.......::--=---'------+---"-------1
' ' □---..--:-'---~----'--'--!........::="-'-'--1----'------f
o __ ___;;__;:c.._~,,__---==--~-=---------+----=--~--1
□--=----~=-:-___:_c:_;__ ___ =-------+--t-',------==-----1
I
•
Qtitp of etarl~bab
JURISDICTION: ________ _ DATE~
PROJECT ADDRESS : ol t/-1 I 5"4 C rl DA G /?,
;o: ../?'P/JL I G '9 /\I T"
PI.AN CORRECTI ON SHEET
SINGLE FAMILY AND DUPLEX DWELLINGS
Plan c heck is l1mited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electr ical Code and state l aws regulating energy
conservation, noise attenuation and access for
the handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections
based on laws and ordinances enforced by the
Planning Department, Engineering Department
o r other departments.
The items circled below need clarification,
modification or change. All circled items have
to be s atisfied before the plans wil l be i n
conformance with the c ited codes and regulations.
Pe r Sec. 303 (c), 1979 Uniform Building Code,
the approval of the plans does not permit the
violation of any state, county or city law.
?
()
I
PLANS
Please make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have
been returned to you by the jurisdiction,
tc.: /:¼~Pl N(,r JJ&if.
To facilitate rechecking , please identify,
next to each circled item, the sheet of
the plans upon wh ich each corr ection on
this sheet has been made and return this
check s heet with the revised plans.
Indicate on plans the name of the l egal
owne r and name of per son r e sponsibl e for
the preparation of the plans . Sec. 302(b)
APPLICANT COPY
CITY COPY :::>
D PLAN CHECKER COPY
Submit fully dimensioned plot plan drawn
to sca l e showing locati on size, and use
of al l existing and proposed struc tures
o n t he l ot. Identify property lines and
show l o t dimensions and all easements.
t Show location of all cut or fill slopes
and approximate finish floor elevations
for· all ~~ructur e unq show eleVationsat a 11 corners. Sec. 302 ( b) 'f:""--· --
Indicate distance from center-line of street
I' or a lley to property line and distance fr~
curh to property line . Sec. 302(b)7 8. ,.., '1:>''='il1-1v'-~ \'"IZ<l,'V\. ~,-?,4~QJ\ ~ '-• •~--.. ✓ ~~ calcutactorrsslla 1 / · be signed by a California State lice nse d
engineer or architect. (Cal ifornia
Business and Professions Code )
D. Fin~ PROTECTION
1-lal ls c loser than
shal l be one-hour
have no openings,
parapets when the
1,000 square feet
Sec. 1709(a)
3 f eet to property l ines
fire-rated construction,
and shal l have 30 inch
building floor area exceeds
on any floor. (Tabl e 5-A
'/oro jections, including e aves, may not e xtend
/" ;~re t han 12 inches into the 3 foot setback
f rom the property line. Sec. 1710 and
Sc. 504(b)
rejections, inc luding eaves, shall be one-
our fire-resi stive constr uction, heavy
timbe r or of non-combustible material if
t hey project into the 3' setback area from
the property line. Sec. 1710
Show loccition of pcrn,.inently wir,od smok
dr tc:ctor. Sec. 1210 -S~u'-P ,3.:; ~r C-mc? C, ,c. S-n-" \ IZ-S
C'. -~1::S, J,IGll'r1 VF: ILA IONS ANO GL/\1.(NG
~c room must contain a minimum of 150 square
/'· ~~-et of supe rficial f loor are,~. Se c . 1207(b )
,/.,,.bitablc roo ms , ot h,:r than kitch<:>ns, shall 7· ~ontain at l eas t 70 sq,rnr r f eet :,f (loor
,1rca. Sec. 1207(h)
/
1,indow area mus t 1:,c at l east 1/10 of the
f loor area and a minimum of 10 squar e feet
pe r Sec. 1207(a). Appears to be deficient
in
' Ope nabl e window are a mus t be 1/20 of the
floor area and a minimum of 5 square feet.
In bathrooms, laundry r ooms and similar
rooms. Minimum is 1.5 sq.ft. (Sec.1205(a)
~~ne-hal f of all requi red window area must
./"· be openable in
Provi de mechanical ve ntilation capable of
pr o viding f i ve air c hanges per hour~-
bathrooms, wate r c los et compartments a undr
rooms and s i milar rooms if required ~1n ows
are not provided. Sec. 120S(a)
No ha bitable room, o ther than a kitchen,
s hall be l ess than 7 '0" in any dimension.
Sec. 1207(c)
/Show that ceiling height for habitable
/'' rooms i s a mini mum of 7 '6". Sec. l207(a)
3/. Show ceiling height for laundry rooms, ✓-hallways, corridors, and bathrooms is a
minimum of 7'0". Sec. 1207(a)
.,/Provide 30" clear width for water
/'• compartments and 24" clearance in
o! water closet. Sec. 17ll(b)
closet
front
'
. Handrails shal l satisfy the fol lowing:
a. Provide handrail for stairways over 30"
high when serving a single dwelling.
k Title 24, Sec. T25-22(b)
No cooking room shall be used for sleeping
purposes, unless complying as an efficiency
living unit. Sec. 1208
Specify safety glazing for glazing in hazardous
locations such as glass doors, glazing
adjacent to such doors and glazing adjacent
to walking sur faces. Sec. 5406
Glazing in shower andhub\enclosures
(including windows) srat'be tempered,
b. Handrail shall be 30" to 34" above the
nosing of treads. Sec. 3305(j) ~ Handrail projecting from a wall shall
have a space not less than 1 1/2" between
the wall and the handrail.
The hand grip portion of handrail shall
be not less than 1 1/4" nor more than
2" in cross-sectional .dimension.
Sec. 3305(j) (see attached)
~ Every stairway landing shall have a dimension,
measured in the direction of travel, at
least equal to the stairway width.
laminated or approved plastic. C l-t'\-fZ. ,.. ,.., Hc.,u) Sec. 1711 (f)(g)~e 4°><\l..1!,0\c'• Ir-I
Sec. 3305(g)
( 4&,-.<,0 -i,.,; '\-1,,\.. (\.,l'¼\'\.-~"')Z. 1 ';, 1.Q. \'\\ ~~ O.l.. JY~<) -~ . St~~pingrooiiissR'lrrr-n.rve-rwi ndow or '"' ~ s.
A door may open over a stairway landing
provided the door, in any position, does
not reduce the clear area of the landing,
in the direction of stairway travel, to
less than one-half the required width of
the stairway. Sec. 3305(g)
/ exterior door for emergency exit. Sill
height shall not exceed 44" above the floor.
The window must have an openable area of
at least 5.7 square feet with the minimum
openable width 20" and the minimum openable
height 24". Sec. 1204
W"."Eaves and cornices may not project into ✓-· a required yard more than 2 inches for each
foot of yard width if required windows
open into the yard. Sec. 1206(dl
~ A mezzanine is an intermediate floor and
/ may not have a floor area exceeding 33 1/3
percent of the total floor area in the room
below, and the mezzanine floor must have
a clear height of 7 feet, above and below.and
must have 65\ of the long side open to the
room below.
/The loft you show does not comply as a
/-· mezzanine floor and is, by Building Code definition, a story ______________ _
D. EXITS, STAIRWAYS, AND RAILINGS
U1r" Floors above the second story shall have
./· not less than 2 exits. Sec. 3302(a)
Required exit doorways shal l be not less
than 36" in width and not less than 6'-8"
i~ height, and shall be capable of opening
at least 90 degrees. Sec. 3303(e)
53. A door may open inward at the top step of •
a stairway provided the top step is not
more than i 1/2" lower than the floor level.
Sec. 3303(il2 g:;). Provide details of winding stairway.
Minimum tread is 6 inches at any point
and minimum 9 inches at a point 12 inches
from the side of the stairway.
b. Maximum rise is 9 inches.
c . Minimum width is 30 inches.
(see attached)
Provide spiral stairway details:
Sec, 3305(d)
a. Minimum run is 7 1/2 inches at a point
from where the tread is the narrowest.
b. Maximum rise i s 9 1/2 i nche s.
c. Minimum he adroom is 6 feet 6 i nches.
Sec. 3305(f l
(see att ached!
SY. Sprial stairways may not be used for required
/ exits when the area served is greater than
400 sq. ft . Sec. 3305(f)
/spiral stairways must have a clear walking
/ · ~pace of 26 inches between the column and
handrail. Sec. 330S(fl
✓.' Provide 36" high protective railing for
_/ porches, balconies, and open sides of landings.
Maximum opening between railings shall be
less than 9". Sec. 1716
SY. Provide I.C.B.O. Reasearch Report and Number
./ for metal stairway, or submit plans and
cal culations and approved fabricator
registered with the Building Department
or note that the stairway fabrication shall
be done under special inspection per the
approved fabrication plans. Sec. 306(al4B
and Sec. 306(f) ✓show how guardrail connection details are ✓-~dequate to support 20 pounds per lineal
· f oot at a right angle to the top rail.
y
Table 23-B
Provide stairway and landing details.
Sec. 3305(bl & (cl
a. Maximum rise 8" and minimum run is 9".
b. Minimum head room is 6 '-6".
c . Minimum width is 30".
0/in buildings over 2 stories in height, provide
/'· 3/4 hour fire-rated assemblies for all
openings in the exterior wall below or within
10 feet horizontally of an exterior stair-
way. An exit balcony with 2 separated
A tairways is . exP.mpt. Sec. 3305
Exterior stairways shall not project into
the 3 foot se tback from the pro perty lines.
· Sec. 3305(n)
(i}. The walls and sof f its o f the enclosed ~seable
/
'
• spa ce ~nde r interior stairs s hall be protec ted
o n the enc l o se d side as r e ouired for o ne-hour
f i r e -resi stive cons tructio~. Sec. 3305(mJ ----,~ IS"--5/f,'' Tl.\~ ,< Ly;\\~ e. J/,;;' ",l '>7 c, • .,.,"t -f-&· Minimum constructionspec1Tf~UTons'-"s'tiail~ (tel\•
,, /ow t 3/8" sol id core self-c losing door
~~~~openi ngs between garage and dwelli ng.
Sec. 50 3(d l r3-Garages are not permitted to open into
T a room used for sleeping purposes. Sec . 1104
1 be made a part of the approved plans 0 ,
(See attac hed) W"-"''D 1uo r-f:>"--t"
ftru "\ r:, O<,t ,;_, i C.c.~ v'V\:;, E. ROOFING '\ -
Y: Specify roof pitch. "7 Roof pitch is not adequate for roof type
72.
y:
H.
specified. Specify minimum pitch of _____ _
Specify roof material and aprlication. y;<. -..
mate rials not covered in UBC ,1.-e ":v\ Q..c •
Specify I.C.B.O. approval number for·~ ';---~
Specify roof slope for drainage or design ,~ 1 ri
to support accumulated water. Sec. 3207(a \(.BO
Show roof drains and overflows. --Sec. 3207(al
Provide skylight de tails to show compliance
with Sections 3401 a nd 520 7 o r provide ICBO
approval numbe r.
Provide plas tic r oof panel de tails t o show
compliance with Section 5206 or provide
ICBO number.
Show attic ventilation. Minimum vent area
is 1/150 of attic area or 1/300 of attice
area if at least 50\ of the required vent )
is at least 3 feet above ceiling joi,7s.
Sec. 3205(cl <:.'<lo~ 1"'••(Y\'\--\2.Qc\'tQ. Et
MASONRY~~'<_-_:'.--· ,r·
Provide fireplace construction details or
H.
note construction to be per attached fireplaJ:;e
standard drawing. Sec. 3707 OlZ-'(11..<.>J10~ ~ ~-~~-Show veneer support and connections comply 1,,.{
· regarding ties and t9 wire in horizontal ~
(
with Sec. 3002, 4,5,6, and Sec. 2516(al • '/"·
joints or note construction to be pefattache~ _.I,)
~~-eets 30-1 or 30-2. cs~ ~~ veJi.<-\.\l~ 1
~-Show height and construction detai 1 s of ---..__ --. ./
all masonry walls. Chapter 24 y1.
_,.JY-Note that cleanout openings shall be·provided
at the bottom of all cells to be grout filled
over 4' in a single pour. Cleanout shall
be sealed before grouting, after inspection.
Sec. 2415
~-Show floor and roof connections to masonry
walls. Connection s hall resist 200 pounds
per lineal foot or the actual design load,
whichever is greater. Sec. 2310
G.
Provide material specifications for mortar,
grout, masonry and reinforcing steel .
Sec. 2403
Show how masonry house walls retaining earth
are to be waterproofed. Provide detail .
Note that special inspection of the masonry will be required for _____________ _
GARAGE AND CARPORTS
100.Garage requires one-hour fire protection
on the garage side of walls and ceilings
common to the dwelling. Table 5-B Sec.503(b)
.All elements supporting floor above garage
to have one-hour fire-resistive protection
on the garage side. Sec. 503. Beams and
AA/ pos ts, not within the wall or ceiling con-
G\f-f'·. ~ struction, must comply with UBC , Table 43-A, Af e or be mini mum 6" dimension beam and mini mum
.l11 If~ pl 8" by 8 • post. '-1f'c ,i ~ ~ . ~Je, ~) ~0el·
Openings !,et·..reen carport and residence
require self-cl osing doors and stationary
windows. Sec. 1214
Show garage framing section, size of header
over garage opening , lateral cross bracing
at plate line and method of bracing garage
front. Chapter 23
NOTE: Minimum plywood diaphragm ratio is
3 1/2 to l or 2'8". Table 24-I
Doors between dwellings and attached garages
may swing in either direction provided
the difference in floor elevation between
the dwelling and garage does not exceed
7 1/2 inches and provided t he door is not
used as the primary means of egress from
the building.
If the difference in floor elevation exceeds
7 1/2 inches, or if t he door is used as
the pr imary means o f egress from t he bui l ding,
additional s t eps o r landing must be provided
in accor dance with stairway reqci r ements,
a nd the door must not swing over the depressed
leve l. (see 3303(i )2 and 3305 (g J .
Provide 18" raised platf orms for any FAU,
water heater, or any other device which
may generate a flame or spark.
Note that continuous fire wall protection
shall be installed behind raised platform(s)
prior to framing platform.
FOUNDATION REQUIREMENTS
Note on plans that"A soils engineer shall
eva1uate any unantic ipated uncompacced f i ll
or expansive soil or other soil problems
disclosed during construction·. Sec.306 (a)l2.
Submit soils classification determination
by a licensed engineer or architect based
on observation, tests, borings, or excavations,
and containing comments on the degree of
expansivenes s, compres s ibility and bearing
value, Sec. 2905
Note on t he plan the soils classifi c a t ion,
whether or not the soil is expansi ve, and
note the allowahle bearing value. Sec. 2905
The foundation plan does not comply with
the soil report recommendation for this
project ~ A-ffi==:G\1t.-O.
Provide notes on the fo~ndation plan_listing
the soils report recommendati ons f or foundatioqs.
slab and building pad preparation. ~ll .. 12.<..>c:.$ •S "o~ C..C,n,\\>I.."\ 1r1u ~~I._-.,. Note on the foundation plan that "Prior
to the Contractor requesting a Building ·
Department foundation inspection, the
soils engineer shall advise the Building
Official in writing that:
l. the building pad was prepared i n accor-
dance with the soils report:
2. the utility trenches have been properly
backfilled and compacted, and:
3. the foundation excavations, forming
and reinforcement compl y with the soils
report and approved plan.•
Provide spre ad
loads designed
or per bearing
an engineer or
footings for concentrated
for 1,000 PSF soil bearing
value as determi ned by
architect. Cha ~ter 29
~ 3how height of all foundation walls. Chapter 23 ~ Show height of retained earth on all foundation
~ walls. Chapter 23
)28. Show distanc e of foundation to edge of
cut or fill slopes and show steepness and
heights of cuts and fills. Chapter 29
Note on plans that wood shall be 6" above
finish grade. Sec. 2417(c) 7.
Note on plans that surface water will drain
away from buil ding and s how drainage pattern
and key elevations . Sec. 2905(f)
r-Dimension foundation per Table 29A.
TABLE NO. 29-A-FOUNDATIONS FOR STUD BEARING
WALLS-MINIMUM REQUIREMENTS
DEPTH or
rDUNOATION
WIDTH THICKNESS 8£LOW
NUMIU THICKNESS or OF or NATURAL
OF FOUNDATION WALL FOOTING FOOTING SURFACE
STORIES (IIIChtl) (Inches) (lnchnl OF GROUND
AND FINISH
CDNCR£TE UNIT GUDE
MASONRY (Inches}
--· -.
1 6 6 l:? 6 IZ
2 8 8 15 7 18
3 10 10 18 8 24
:'\OTES:
\Vhere unusual condition, or frost conditions 3re found, footi.ngs and
fo\lntl:ltions ~h~Jl be :is requirt'd in Section 2907 ('1).
The ground under the floor mAy be ea:cavated to the t·lt>\':ltion of tht"
top of the footin~.
sills to be pressure treated,
,/Note cross bridging or blocking. Floor 7~-joists and rafters more than 12" in depth
and spanning mo re t han 8 feet shall be
supported late ra l l y by bridging at intervals
_ not exceeding 8 Eeec. Sec. ~2~5~0::!:='....,.'"-:,--.
Show blocking at ends and a supports
of floor joists, and for raft exterior
walls. Sec. 2506(g )
1/4. Show solid blocking at ridge line and .✓--at exterior walls on trussed roofs.
Sec. 2506(g)
Show double joists. Floor joists shall
be doubled under bearing partitions running
parallel with the joists. Sec. 2518(d) 5
u,{. Show rafter ties. Rafter ties shall be
/ spaced not more than 4 !eet on center
where rafters and ceiling joists are not
parallel. Sec. 2518lh) ✓ Show rafter purlin braces to be not less
than 45 degrees to the horizontal. r Sec. 2518(h)
• Show 1/2 " minimum clearance between top
plate of interior partitions and bottom
chord of trusses. (To ensure loading ·,r, will be as designed.)
/l ij,9 . Show double t op p late with minimum 48" ;:J; lap splice. S~c. 25l8(g )4 1/'(Gb Show nailing will be in compliance with
/
7 : :::::d:
5
~:~e stops between stories, between
top stor y and roof space, at ceilings
and floor levels in i nterior and exterior
walls, in mansard roof or eyebrow so no
concealed or furred space is greater than
10' horizontally or vertically, between
st air stringers at top and bottom and
between studs along and in line with Show foundation
or equal. Sec. 2517(c) 3. g 0
bole size and spacing10Yi ~c;-0 1"Y\QJ.(l",
stair run adjoining stud walls and partitions,
at perimeter of sliding door pockets,
)>6'·
Show foundation
Sec. 2907(e)
Specify size, ICBO number and manufacturer
of power dri ven pins . Show edge and end
distance and spacing. Sec. 306(f)
Show size . imbedment.And location of
down an~,w•■ on foundation plan. Sec. 2312(f)
Note on plan that hold down anchors must
be tied in p l ace prior to foundati on inspection.
Sec. 2 312 ( f )
Show adequate footings under a l l shear
wal ls. Sec. 23ll(e)
Show stepped footings for s lopes steeper
than 1:10. Sec. 2907(c )
?2·
between chimney and wood frame using metal
or i ncombustibles for the Eire stop and
at other places that could afford passage
of flame. Sec. 2517lfl
Show stud size and spacing. Maximum allow-
able stud heights: 2 "x4"@ 16" is 14';
3"x4"&2"x6"@ l6"o.c. is 20'. Sec. 2518(g)2
Note an A.I.T.C. Certificate of Compliance
for glued laminated wood members shall
be given to the Building Inspector prior
to erection. Sec. 306(f)
Detail all post to beam and post to footing
connections. Sec. 25l7(c) 4
Specify nail size and spacing for all
shear walls, floor and roof diaphragms. m . Show minimum 18" clearance from grade t o Indicate required bl ocking. Maintain
bot tom of floor joists and minimum 12" maximum diaphragm dimension ratios.
clearance to bottom of girders. Sec. 2517 (Tables I,J,K).
~O'-Show pier size, spacing and dept h i nto 1 ~✓ Show 3"x4" or 2"x6" studs in first story r· Show minimum under floor access of 18"x 24". Provide truss detai ls and truss calculations. Sec. 251 7
undisturbed soil. Table 29-A ~✓--· of three story building. sec. 2518(f )
l 4Y. Show minimum under floor ventilation equal y Provide roof framing plan. Sec. 302(a)7
7 · to l l/2 sq. ft. for each 25 l ineal feet . Provide framing sections through ______ _
of exterior foundation with openings as
,lose to corners as practicabl e to provide
cross ventilation on at least two approximate-
r.:;.:_~ly opposite sides. Sec. 2517 ~~ S.Wi..v .-:h.c:j'l.l-cv, ~A-'-~'1 ·
I. FRAMING
#· Show all joists, rafters, beams, a nd posts
2" to 4" thick to be No. 2 Grade Douglas
Fir-Larch or better. All posts and beams
5" and thicker shall be No. l Grade Douglas
Fir-Larch or better. (Tab le 25-A-l)
Show wall bracing. Every exte;ior wood
stud wal l and main cross partition shall
be braced at each end and at least every
25 feet of length with lx4 diagonal
let-in brace or equivalent. Sec. 2518(gl5
Section 302(a) 7
for opening over 1£ Specify all header sizes r~· 4' wide. Sec. 2518(g) 7
/-Provide calculations for ___________ _
Section 302(a) 7
In areas subject to water spla~h and in
exterior locations, wood colum~s and posts
shall be supported by piers proJecting
at least 2" above the finished grade and
shall bear on a metal base plate or treated
wood unless the columns or posts are foun-
dation grade redwood or cedar. Sec. 2517(c)4
;_r-Yw location of attic access with minimun ~ ;~~e 22" x 30". Sec. 3205
,a/~ ~w draft separation for attic areas r· .~ e xcess of 3,000 sq.ft. Sec. 3205
1 a~ Show draft separation for space between 7· droooed ceilings and floor above in excess
of i",ooo sq.ft. Sec. 2517
. Specify plywood grade and panel indenti-
fication index. Table 25-J
When roof pitch is less than 3:12, design
ridge as a beam. Sec. 2518 (h)
~ood shear walls shall not be used to Y9· ~esist horizontal forces contributed by
masonry in buildings over one story in
height. Sec. 2516(b)
~ Show access to the attic or under floor
furnace to be minimum 30 inches by 30
inches. Sec. 708 & 709 UMC
,JJ4 · Note that passageway to the attic f urnace
shall be unobstructed and have continuous
solid flooring not less than 24 inches
wide. Sec _708 UMC
Show permanent electrical outlet and
lighting fixture controlled by a switch
for the attic furnace. Sec. 708 UMC
Show details to comply with Section ?09
for furnace under the floor, Section 708
for attic furnace, or Section 710 for
roof or outside furnace.
Note on plan, gas vents and non-combustible
piping passing through three floors or
less shall be effectively draft stopped
at each floor or ceiling. UBC Sec. l706(a)6 1✓ Gypsum lath and plaster, gypsum sheathing 7 ·· board and gypsum wallboard shall not be
~sed in vertical diaphragms to resist K. ELECTRICAL (National Electrical Code)
forces imposed by masonry or concrete All wiring shall comply with the National Electrical
construction. Table 47-I code.
1 a/ If cripple wall studs are le~.s than 14" • ~2 . Note on the plan the amperage of electrical 7· framing shall be solid blocking. Sec.2518(g)6 5 rvice.
,av' Cripple wall studs _exceeding_4 feet in r22.Qthe electrical installation is more
~-height shall be 3 inch by 4 inch or 2 . ~ 200 amperes, show panel location
inches by 6 inches when supporting 2 stories. ?;' and provide a single line diagram and
Sec. 2518(g)6 ' load calculations including:
Show plywood sheathing over exposed eaves,
or other weather exposed areas, is exterior
grade. Sec. 2517(g) 3
Show a weep screed at the foundation plate
line on all exterior stud walls to be
stuccoed. Sec. 4706 (e)
· ~ Provide an approved waterproof building
paper under wood siding. Sec. 170l(a) fui. Specify an approved flashing for exterio~~ ~ openings and parapet walls. Sec. 320~'-'V r-Show corridor width to be minimum 36". ___.
(l~. ::::i::
0
:::~s layout for 30" x 30" attic
~ access.
lA1(° Ridges, hips, and valleys shall be at r ·-· least one size larger than supported
/afters. Sec. 2518(h) 3
..J-89· Provide metal straps across ridge beam
• and rafters.
J. MECHANICAL
Al l heating, ventilating, and cooling s ystems
and appl iances shall comply with the Uniform
a. Wiring method employed.
b. Sizes of all conductors, switches,
circuit breakers, fuses, and conduits.
Approximate length of service feeders.
Provide plot plan showing services,
c.
d .
e.
all panel locations, circuit arrangement
and load distribution on panel busses.
Provide typical panel schedule(s).
Dwellings require minimum 100 amp service.
Show location of all elec trical receptacles.
Electrical receptacle locations and/or C. 1 spacing is not adequate in 1.1:1;-r '-½+\Io S'll.lD'f >
'.l),l\l' >V'-t. \. '"''""'I l C <;.ee f\--T1J:!<::h :2&)
✓-At least one receptacle shall be installed
outdoors, in basements and attach~d garages,
other than laundry outlets . Art. 210-25(b)
Show minimum dwelling lighting (NEC
Art. 2l0-26(a l and~ in g<',r_age, b~t;b§..
and outdoors. NEC Art. itcr::aTar.----.___.....___... __ .
Note "UFER" ground t o be p r ovided (NEC).
Art . 250-8 1
Mechanical Code. PLUMBING (Uniform Plumbing Code)
Show the~ocation and~f all ~
heating and cooling appliances or systems. All plumbing shall comply with the Unifrom ~ Plumbing Code. _ Show source of combustion air for furnace , e will comply with Chaper 6, U.M.C. . Show water heater size, typ and
~ location on plans . . Every dwellirq unit shall be provided with ~ air
heating facilities capable of maintain-/~7. Show method of providing combustion
i ng a room temperature of 70• F. at 3 to fuel burning water heater. Sec. 1307
feet above the f loor in all habitable z.a-ir." Fuel combustion water heater shall not be
rooms . Show basis for compliance. UBC _,,,,, installed in bath or bedr oom or in a closet
Sec. 1211 opening into bath or bedroom. Sec. 1309 ~ Show minimum 30" deep unobstructed working ,.< Provide adequate barrier to protect water
•· __,,--:space in front of furnace. /"'·~er from vehJ.cle damage. Sec. 13'10
~-~ote on plans.clearances to be per manufac-~~ Sho T and p valve on water heater and
turers listi ng. Sec. 704 UMC /~ ow route of discharge line to exterior ~ Furnace shall not be installed under any ~ Sec. l007(e)
stairway. Sec. 704 UMC 242 Provide dryer vent to outside. UMC
J.D6":.Furnace shall not be installed i n any r Sec. i 9o3
bedroom, bathroom, closet, or in c o nfined 43 Note on the plan that hose bibbs and lawn
s pace with ac cess only through s uch room, sprinkler systems shall have approved
un less specif i ed as direct vent appliance, backflow prevention devices . Sec. 1003
e nclosed furnace or electri c heating appliance.
s ec. 704 UMC Y· Q Show ICBC approval for prefab fireplace ~ and provide approved installation instructions
at job site.
Shower stall shall accomodate a JO"c i rcle
and have a minimum f loor area o f 900 sq .in.
UPC 909(d)
~ NOISE INSULATION (DUPLEXES)
Show details of duplex common (party) wal ls
a nd floor /ceiling assembl ies to achieve
a Sound Trans missi on Class (STC) rating
in walls of 50 decibles and an Impact
Insulation Class (IIC) rat ing on floor/
ceiling of 50 decibles. Title 25
Show how penetration of assemblies for
piping, electrical devices, recessed cabinets,
bathtubs, soffits, or heating ventilating,
or exhaust ducts shall be sealed, lined,
~Outdoor pools wi t h fossil fuel heate r s
(
0
~. require pool cover s as well as ot her energy
saving device s such as t ime c locks, e~c .
T20-1406
MISCELLANEOUS
Show a minimum 2" air space and flashing
between plante r and building walls.
Sec. 2517 (e )
Specify material to be used under the shower tile. Sec. 1707(a )
or insulated to maintain required sound c:J, /\......_
transmission rating. Titl'e 25 (>~e £1,,lk» ~ ) Specify lath and plaster to comply with Chapter 47, UBC.
Provide insulation in wails and ceiling
to achieve STC of SO between garage and
living area if garage use is not controlled
by resident Title 25.
!'!:./ENERGY CONSERVATION
71. All additions to existing residential • buildings must comply with Title 24
energy r egulations. Addi tions exceeding
301 o f the exis ting build ing require s the
existing and add ition t o have R-19 ceiling
i nsulation if the existing ceiling area
is acce ssible fo r i nsulation i nstallation
CT20-l 40 l Cc).
Speci fy the i nsulati on R valves f or walls,
roof and ceiling. (R-1 1 for walls: R-1 9
for ceilings, or provide details and analysis
for alternate design. T20-1403 Table A & 2B.
Specify the gross floor area or heated
portions of the dwelling, and the area of glazed openings on the plan. (T20-l430)
Provide an analysis justifying increasing
the single glazed area beyond 161 of the
gross floor area. Show method to reduce
heat loss to that which would occur with
basic glazing. (T20-l402,def.)
275 Pr ovide energy analysis to show that the
;'(l.. ~bonnet capacity of the gas central furnace ~~ \',b( does not exceed the building design heat
1(,-0:r,.> '\f l oss by more than 301. (Exceptions: ~ / 48 ,000 BTU Hr. output furnace. See also ?JO California Efficiency Adjustment.) T24-l404
Note on plan that alt tranverse ducts,
plenums, and fitting joints of HVAC system
shall be sealed with pressure sensitive
tape or mastic to prevent air loss. T20-1404
Note on plan that insulation of ducts shall
conform to UMC Section 1005. (T20-l404)
Note on plan that all doors and windows
to the exterior or to unconditioned areas
shall be fully weather striped per ANSI
Standard. (T20-l403).
Note on plan that back draft dampers are
required on all fan systems exhausting
air from the building. T20-l403
Electrical resistance space heating shall
not be used unless:
~-601 of heating/cooling is supplied
by a nondepletable source.
b, supplements a heat pump system.
c. less t;han 101 of total heating system.
d. l i fe cycle c ost analysis justifies.
T20-l404'
Note on plan that all heating and cooling
equipment efficiencies shall conform to
Title 20-Chapter 2, Subchapter 4, Article 4.
(751 for forced air furnaces) .
. Note on plan that no natural -gas, central
heating plant may be installed without
n Intermittent Ignition Device. T20-l405
Electric resistance water heating is not
permitted unless verfied as cost effective
by a life cycle cost analysis. T20-l406
Two 3/4" copper pipes must be installed
from water heater location to convenient
l ocation of future solar panels (City Ord.)
Provide sleeves (roof jacks ) in roof f or
two future 3/4" copper pipes to C1Jnvenient
location of f uture solar panels (City Ord.)
Note that solar water piping is to be i nsul ated
in areas that are not heated or cooled. (City Ord. l
/~ See attachment for roofing requirements.
, '',c8/. <.?,\1<:-e~ i..u,4<,,i Sc,1t,::;, ~.-1,n,..e e ~l'Q.. r1-~1 ... \'Y\ l -~ ·D\...>'7>~--. '"" ~\\S e .-9cwtS.1ve S c ,'--1,l,e
// ...--'.:,1'()u..,_o ~\?Jluv<.: ('1-t...f v~~ OlZ: s..,:1 't.-Sf'
-:-Mc 0 , <;... '-"'-n ~YV'i. ft x=-v,u ';;>~ !.. ~1..,\..~ '1~-c& +., ~ ~e11,~Qt
,Y\. ;;:>.:.L.-\-u,\ -tt> -.,,.s-,,z.e <w~l•"""'''e ._, \~
.Su\l..S ~~ , C'::>e(i!. ~l..5o \?.."!..: 'B:.-1?..'-}
NOTE:
The plans were reviewed based on the information shown on
the plans. If the plans are in error, or changed during
construction, the permittee shall contact the Building
Department for review and prior approval before proceeding
with the work:
0 Building plans are substantially correct
and complete.
By: ________________ _
Date: __________________ _
0 Building plans would be substantially correct
and complete if minor corrections are made
at counter.
By: _______________ _
Date: __________________ _
~ Building
complete
If you have any questio
ca 11 ·--::r; v'V\
pl ans require ma jor corrections and
plan recheck, by plan check
this plan check, please
al ~,+) s-<.:.o-1tc.:.e,
We ·.rould also be pleased to meet with you, at ),:, charge, if
addi tional assistance is needed.
byt
Jurisdiction~~
VALUATION AND PLAN CHECK FEE
□ Bldg, Dept.
tl l::-56--1 L
PLAN HECK NO. 8.:2-/ ~ 4-
BUILDING ADDRESS ;;:).. '--/ f ( 5 /1-C l4t .J) ,lz Ct /Z CL 0-
APPLICANT/CONTACT '/Vl r'h1-l< LJ,~-€1\o..Q..Q PHONE NO. </tj-{;}.-OC, ~lf
BUILDING OCCUPANCY /C-3 J>ufk'{.. DESIGNER PHONE ~
TYPE OF CONSTRUCTION tl-hJ CONTRACTOR PHONE ~
BUILDING PORTION BUILDING AREA VALUATION VALUE
MULTIPLIER
£_11/1 '1 f/ ../,, 7"191_,..
~'2 _.., ,, Is . ....,_ ... , (),7, lf-{, s-'5" J./,~ ~ ;c;1;-~-;u
, I
Tucks /:c) I ,__, yz. -... ,
Vv,,fs ~ .310 6~ ~ /08 , I
-~fe5 I CJ/~ II fl ft.f..2.., ///111-rl , .J /
Air Conditionine
Commercial
Residential
Fire Snrinklers
Total Value Joi~[Ql
\
Building Fermi t Fee ----=-7_0_S: __ , _5_~_o_,,__.,.__
Plan Check Fee ______ Lf. __ S_8_,__.lr:$""-----·-1;_0_
INTERDEPARTMENTAL INFORMATION SHEET
BUILDING DEPARTMENT DATE : ---------
Bu I LD ING AD DRE s s = _,Z"----4~1-1 _7At:AL...!..-C~D'""'-'A~_G~\ eclE'----=-"~---~;......E~C~E;,....I......._.VL-E~DJ-.a
/ -'D~L._,,,._)B[½--,~1=::1;=---,)(P>c------------MAY 261982
PLANNING DEPARTMENT CITY OF CARLSBAD n Building Department
ZONE ____ ~~-J_?r-":...__ __ LOT SIZE _________ LOT WIDTH ________ _
UNITS ALLOWED UNITS PROVIDED ------------------------
PARKING SPACES REQUIRED --~/;4\ ______ PROVIDED !" \!-=:::~
% COVERAGE ALLOWED _____________ PROVIDED \~~c-+-\➔~----------
BUILDING HEIGHT ALLOWED PROVIDED
FRONT SETBACK:
ALLOWED
PROVIDED V'
INTRUSIO_N_S_--1~~-=---
SIDE SETBACK:
-----------
REAR SETBACK:
\~
R.O.W. _____ INDUSTRIAL JA~ LJ-7 q -ZPRO~ I~
SEWER CONNECTION DRIVEWAY LOCATIONS --------"=--V/
GRADING PERMIT __ .:_:__:_::=!....!:...-EASEMENTS _________ DRAINAGE ____ _
LEGAL DESCRIPTION ~ -----------------------------
ADD IT ION AL COMMENTS __________________________ _
FIRE DEPARTMENT
SPFiliKLING SYSTEM ___________ FIRE PROTECTION EQUIP. _______ _
FIRE ALARJltS EXITS _______________ _
FIRE HYDRANTS LOCATION _________________ _
ADDITIONAL COMMENTS ____________________________ _
OK TO ISSUE: _____ DATE _______ OK TO FINAL ______ DATE ___ _
WATER DEPARTMENT
REQUIREMENTS OF APPROPRIATE DISTRICTS MET ________ DATE ________ _
,(
\
(itp of ({arlsbab
JCRISDICTION,________ o•rr. f'5PZ
e?OJECT •••••ss,.:lt/{J S8C8/28 C((?<,te
Tc, IRfiaz,tfee •
PLAN CORRECTION SHEET
,, 'l
Phn Ch•ck No,c:?2'.-/4 ¥ .:zz::
• .,,. r,hns rocoi•,od by jurl•dlctlon /V~ '-/IS-
'1<1t• r,llna received by phn checke,,t(,,;<a d/!t.,
:lat~ 1n1thl phn check completed ,C£/ by~
tjia,ii1z
fnq[~~~D1 PLEAS£ AtAD
rt•n check is l1~ited to technical requirement•
c~nt•1ned in th• Uniform Building Code, Unifor■
Pluab1n9 Code, Uniform Mechanical Code, National
Electrical Code and atate laws re9ulatin9 energy conservation, noise attenuation and access for
the hM,dicapped. The plan check i■ based on
r~9ulat10ns enforced by the Duilding Inspection
O~partment. You may have other corrections
b~sed on laws and ordinances enforced by the Planning Cepartment, tng,neering O~partment
or other departments.
T~e items circled below need clarification,
rod1fication or chan9e. All circled items have
tc be satisfied before the plans will be in
conforfflance with the cited codes and re9ulationa. rer Sec. 303 tc,, 1919 Unifora 8uildin9 Code, the approval of the plane do•• not perait the
Vlolat1on of any state, county or city law,
1. all correction• on the ori9inal
and aubmit two new aets of prints,
ny orig,nal plan sets that may have
returned to you by the jurisdiction,
~-To facilitate re ccking, please identify,
rcled item, the sheet of
n which each correction on
th1s sh has been made and return this
heet with the rev1sed plans.
( :l
D APPLICANT COPY
C CITY COPY ~
D PLAN CHECKER COPY
ft ,....,
-----.. '·, -"• --+r-.1 Ir. •.1n,. . ~ ·-r?n ,~ .. •
In:;>_ r, J.J klJ!f?i<"<>, 7 11-r • ,
,..-,.,, ~le,,, 8'1 ir11G1nq c-u -ftp
-i?;,t.,,o ,2/r,,u --..L.-• I .
'11 •---" {q_ l'J-.fr.:? c::h,,;, L-.Jl'&ld' _t.,,
._ ao.,n ~ .,, ~ ,7.CJ,,1 -' -f P.P./1 'Sec, 33>S(J2,_
I
/~ J / J7L7-I tu,r _,,_ ·' /1!I
~ J.,._ ...L -.:z 4_. -rv.6. J
" -_, ,.fl,,, ,
r --(/
(G/ QI{ o~t q//, '-s -h-.
0=-/. :,,,:;> ,,~,,,,-:. ,r,r 1~-,rR?,,~ u
/3c'IL-T" -v"" .?Z«>C {:See.
,4-,.; • " ,, } -
(cf'J " ~7 ,~ 'cl~s
--HI c..l.so J.,,, "G,p£ ,,
----· . -;-y· ( &>In
-·------·---
-.. -
,,
.,. ;i ,.: :;a.,
CORRECTIONS
'·• .. ,
APPROVED:
H ------------------
' I~.~~~·~------'--~•--'-=-=
I •
I ,
LEUCADIA COUNTY WATER DISTRICT
APPLICATION FOR SEWER SERVICE
Owner's Name Mark Witherall ------=-----"-'--'c......,..:....:...-=.:...:.=!.-=....:....:,.__~------~
Mai 1 i ng Address --=2,_,4-=-0=--9 _-_ __,_A'-=-Bu,,,_,re-.;:g...,,o""s·_C=o=u=r-"t ______ _
Service Address:
Carlsbad, CA~
.,2 '--/II a;:
Tract De sc r i pt ion : __,_,1 oo<..at<--L] __,_40"'-2..., _,.S'-"'o.,.._y-"'th"'-#"_,_J _______ _
Assess or' s Pa rce 1 r~o . ----=2'-'-1 =6-_]..,.9'--"0_-x..34..._ _______ _
Phone No . 942-0684 ---='-'--=-="-=-'~-
SEWER PERMIT ISSUED UPON
RECEIPT OF BUILDING PERMIT.
I ,.
BUILDING PERMIT MUST BE
APPLIED FOR BY e,·c-lft-Qy.,
Type of Building ___,d.,_,u~p'-!..l.,,...ex,.,__ _____ No. Units 2 Connection Fee $ 1,200:00
Lateral Size: 411 611 8" Saddle Easement Connection (pre-pd 400.00}
Extra Footage: __ @$ ___ _
Amount Rec'd t .8..0_Q_Jl{L
Ck. No/Cash ~~~
Date ..!l/28/79
Rec'd By S. Williamson
Extra Depth: ___ @$ __ _
Lateral Fee
Prorated Sewer
Service Fee
800.0Q
Tota 1 $ 1 , 200, 00
The app1ication must be signed by the owner (or his authorized representative) of
the property to be served. The total charges must be paid to the District at the
time the application is submitted.
If a service lateral is required, it will be installed by the Leucadia County Water
District. The service lateral is that part of the sewer system that extends from
the main collection line in the street (or easement) to the point in the street (at
or near the applicant's property line) where the service lateral is connected to
the applicant's building sewer. The applicant is responsible for the construction,
at the applicant's expense, of the sewer pipeline (building sewer} from the appli-
cant's plumbing to the point in the street (or easement) where a connection is made
to the service lateral.
The connectiQn of the applicant's building sewer to the service lateral shall be
made by the applicant at his expense. The connection must be made in conformity
with the District's specifications, rules and regulations; and IT MUST BE INSPECTED
AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY THE APPLICANT.
THE APPLICANT, OR HIS AUTHORIZED -REPRESENTATIVE, MUST NOTIFY THE DISTRICT AT THE
TIME INSPECTION JJ DESIRED . ANY CONNECTION MADE TO THE SERVICE LATERAL OR COLLEC-
TION LINE WITHOUT PRIOR APPROVAL AND INSPECTION BY THE DISTRICT WILL BE CONSIDERED
INVALID AND WILL NOT BE ACKNOWLEDGED.
The prorated sewer service fee is based upon the date the District estimates that
service will begin and cover~ the balance of the fiscal year. There will be no
additional fee or refund if service actually conmences on a different date. For
succeeding fiscal years, the sewer service fee will be collected on the tax roll
in the same manner as property taxes.
The undersigned hereby agrees that the above information given is correct and agrees
to the conditions as stated. '
0 ;;,_ II -\,___\ \,DJ_ 0 J
Owner's Signature f6# Da e Account No.
__ :, ,,-----~---:::. ·~;:½t-~ :::-__
~-.• ,f ---,--..•. --=-
)!( lflJ'!cv¢,_,Af0,,AA/4.Jl.~l!M1.,~WAAIAAAIAAAf;J,l,.IA AM.1Ji.k-./4.Alwi,JA.M/;:;./4. AAAA n ~ ~~~ ? « ~ ~ (E r: r 1 if t r a ! r 11 f ® r r 1t 1.1 a tt r y ~ ~ ~ ~ CITY OF CARI._SBAD ~ ~ ~ ~ This Certificate issued pursuant to the requirements of Section 306 ~ ~ of the Uniform Building Code certifies that at the time of issuance ~
«i this structure complies with applicable ordinances of the City ► ~ regulating building construction use. ~
/4 ► -<€ Use Clossiflcotioo DU p 1 e X Bldg. Pe,mit No. 8 2-1 6 4 ~ ~ ~ ~ Group _____ Type Con5truction, _____ Fire Zone ______ Use Zone______ ~
4; Occupant Load --;:;-----;;--c~,"'.;::----------,==-,-~--~-------~
-<i; Owne,ofBuilding Mary, Bill Cramer Md,ess 7527A Jerez Ct. ;l'>-j B,,ldingAdd,ess .. 2411' &·2413 Sacada Ci[.~0];~ Carlsbad, CA. 92008 t ~ -~ ~ "'7',f--» ~ --------------,-----B)t§Ji..f---_::~~~l_:,_,_,~14..4,..~-----~
~ ---------------'~--=--1-=------1--------~ « » ~ NOTE: Alterotion:!i, changes, additions or chong,u of occup~ncy nu !Hies this cer ificote. ~
4 (Post in conspicuous place} ;;>
~"'1W"'1'W ''N"(l'l/t"'l"'J'W\fW"'l!/'':"'o/''1WV'l!/VV/ l/fW'¥'V ''v'VV"f\'1'3/'1!/fi'V"{IW'V'<iV''f"cf!''I/V'l'/W'~'){