HomeMy WebLinkAbout2906 ROOSEVELT ST; ; CB130324; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
02-27-2013 Cogeneration Permit Permit No:CB130324
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
2906 ROOSEVELT ST CBAD
COGEN Sub Type: PHOTO
Lot#: 0
Constuction Type: NEW
Reference #:
Parcel No: ~0e~'<>,-oO
Valuation: $7,200.00
Occupancy Group:
Project Title: VERMILYEA RES -PHOTOVOLTAIC
ROOF-MOUNTED, 18 MODULES.
Applicant:
SOLARCITY
3055 CLEARVIEW WY
SAN MATEO CA 94402
650-638-1028
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Green Bldg Stands (SB1473) Fee
$107.27
$0.00
$75.09
$32.41
$0.00
$1.00
$1.00
Owner:
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Additional Fees
TOTAL PERMIT FEES
Status: ISSUED
Applied: 02/05/2013
Entered By: SKS
Plan Approved: 02/05/2013
Issued: 02/27/2013
Inspect Area:
Plan Check #:
$0.00
$0.00
$0.00
$0.00
$216.77
Total Fees: $216.77 Total Payments To Date: $216.77 Balance Due: $0.00
FINAL APPROVAL
Inspector: Date: ~ -Zt/~ /.J Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition• of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
r i I hi h rmi · n h
«~'> Building Permit Application
1635 Faraday Ave., Garlsbad, CA 92008
760-602-2717 / 2718 / 2719
Plan Check Ne. 06 \ '7:, 0 )'2,
~ CITY OF
CARLSBAD
JOB ADDRESS
Fax: 760-602-8558
www.carlsbadca.gov
Est. Value
Plan Ck. Deposit
Date
SUITE#/SPACE#/UNIT#
CT/PROJECT# CONSTfl. lYPE OCC. GROUP
EXISTING USE PROPOSED USE GARAGE (SF)
CONTACT NAME (H DM'erent Fom Applicant)
ADDRESS
ZIP
PATIOS (SF) DECKS{SF)
APPLICANT NAME
FIREPLACE
YES □#_ NOD
AIR CONDITIONING
YES □ NOD
Me...c~~A~r~,~P_-\-~--,1-e-·
FIRE SPRINKLERS
YES □ NO □
CITY STATE A 2. tl (
PHONE FAX FAX
EMAIL
PROPERTY OWNER NAME
ADDRESS AD RESS • .
. s-3 C\c."-
CITY ~~._t-c -
EMAIL
ARCH/DESIGNER NAM£ & ADDRESS STATE UC.# STATE UC.# ~
(Sec. 7031.5 Business and Professions Code; Any City or County which requires a permit to construct, alter, improve, demoliSh or repair an~ structure, prior to its issuance, also requires the applicant for such permit to file a siJ;!ned statement that he ls licensed pursuant to the provisions of the Contractor's License Law !Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 031.5 by any applicant for a permit subject$ the applicant to a
civil penalty of not more than five hundred dollars {$500}).
WORKERS· COMPENSATION
Workers' Compensation Declaration: I /Jeleby affirm under penalty of perjury ona of/he following declarations:
□ I have and will maintain a certificate of con&ent to self-insure for workBfS' compensation as provided by Section 3700 of the Labor Code, for Iha pertormance of the work for which this permit is issued.
,6";" have and will maintain workers' compe~s~n, as required by Section 37QO of the labor Code, for the performance of ~El, work_for wh!ch this pennil ii,. ;,.!l;•Jed. My wori<ers' compensallon nraz, ~..,. and policy
numberara:!nsuranceCo. ?.,,✓-,C \.::J fux'.'.'-!<---✓-1 ca Cl PolicyNo. lAL-"11" 1:\Ylt·1L<.I __ ExpirationDate s ( ---. ":.I ~I
This section need not be completed if the permit is for one hundred dollars ($100) or less. □ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I sha!( not employ any person in any manner so EIS to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to s11cure worjers' compensation coverag11 is unlawful, a shall subjectr-en employer to criminal penalties and civil fines up to one hundred thousand dollm (&100,000), in
addition to the cost of compensation, dam,u 1,~vid1or in S ion 3706 of the r code, interest and attorney's fees.
~ CONTRACTOR SIGNATURE ~ 'J
i hereby affirm that I am exempt from Contractor's J!icenss Law for lhe following reason:
O I, as owner of the property or my employees with wages as their sole compensation, will do the 'NOil( and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
Licerise law does not apply !o an owner of property who builds or improves thereori, and who does such worn himself or through his own employees, provided that such improvements are not intended or offafed for
sale. If, however, the building or improvement is sold wilhm one year of completion, the owner-builder ·Nill have Iha burden of proving that he did not build or improve for the purpose of sak!).
i ,'J !, as owner of !he propertv. am sxclusive!y contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Gontractor's IJcense law Joes not apply to an owner ,)I
;:iroperty ll"ho builds or imoroves ~hereon, and contracts for ,uct, projects with contractor(s) lfCensed Jursuant to the C:ontractor'; license !.aw).
.::, ,Jm c,xemot 'Jnder Seclicn _____ ,Business 3nd 0rofessions ·'.::ode -'or this :eason:
1 :1er;ona1ly plan :o :xov1de '.he 11ajor ·aoor -3.nd 11ater1a1s 'or •Jonstruction 11 rhe oroposed ;ir<Jperty 'mprovernent. ·".:1 '95 ::l 'l0
(. 1 (have,' have not) ;igned -m application ior -3. building permit for The proposed Nork.
1. 1 flave ,-XJmracted with ;he following person (firm) (0 provide the proposed coostruclion ;include name actdmss I phone I contractors' 1ica11se riumber):
4., o!an <0 ;:irovide portions rJf the work, but I 'lave riired rhe following person to ·;oordinate, ·;up01Vise 3nd provide 1ha major wort; (include name I address I phone/ ,_;ofliraclor$' 'icense number):
j_ 1 will provide some of 1he work, 1ut I have ,;ontracted /t,ired) •he following persons !o provide 1he work mdicated (inelude name I address I ohone I fype •JI work):
,z5 'SOPSRTI JWNES llGNAT';:--~ s,£ OATc"
ts lhe applicant or Mure building occupant required to submit a business pla'1,9CUtely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of lhe
Presley-Tanner Hazardous Substanca Account Act? □ Yes S" No
Is !he applicant or future buMding occupant requi!Bd to obtain a permit from the air pollution control district°' air quality management district? □ Yes ~
Is the facility lo be conslructed within 1,000 feet of the outer boundary of a school site? □ Yes □ Na
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONlROL DISTRICT.
I certify that I have read the appllcatiofl and state that the aboYe lnfonnation is conect:and tbat the infonnation on the plans Is accurate. I ag,ee to comply Min all Clly ordinances and Stal& laws relating to bul~ COftSCrudlun.
I hereby aullorize iepresenlative of lhe Clly al Carlsbad lo enter upoo ~• above ""nooned property ilr ilspeclilrl purposes. I Al.SO AGREE TO SA~ WEMNIFY AND KEEP HARM.ESS THE CITY OF CARlSBAD
AGAINST ALL lll'JlllrTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAJNST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA pemit is required br excavatioos over 5'0' deep and demolition or COOSlruc:liJn of structul8S over 3 sbias i1 heght.
EXPIRATION: Every pe,mit issued by the Buik:ling Ol&:ial under the provisb"ls of this Code shall expie by !inilaOOrl and become null and void if the buidi,g or WOik auflonzed by sud, pemit is not a>rnmencad wih1
180 days from~• dale of such pemil or ~lhe bu or-au1llorized by such pennil • suspen abandoned at any t" aflar'1e -• fora · ol 180 days (Sedicn 106.4.4 liliilrm Eklidiig Code).
AS° APPUCANrS SIGNATURE DATE
Inspection List
Permit#: CB130324 Type: COGEN PHOTO
Date Inspection Item Inspector Act
06/21/2013 19 Final Structural RI
06/21/2013 19 Final Structural PB WC
06/21/2013 35 Photo Voltaic (PV) PB AP
06/21/2013 39 Final Electrical PB AP
05/31/2013 35 Photo Voltaic (PV) MC co
05/31/2013 39 Final Electrical MC co
Monday, June 24, 2013
VERMILYEA RES· PHOTOVOLTAIC
ROOF-MOUNTED, 18 MODULES.
Comments
AFTER 10 AM
SEE CARD
Page 1 of 1
DATE: 02/15/13
JURISDICTION: Carlsbad
PLAN CHECK NO.: 13-0324
EsGil Corporation
In a!artnersnip witn qo..,ernment for <Buifaing Safety
SET: I
PROJECT ADDRESS: 2906 Roosevelt Street
PROJECT NAME: Vermilyea 3.6 kWatt Solar Photovoltaic System
□ ~PLICANT
~URIS.
□ PLAN REVIEWER
□ FILE
[SJ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
[SJ Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person E-mail:
□ REMARKS:
By: Eric Jensen Enclosures:
EsGil Corporation
□ GA □ EJ □ PC 02/05/2013
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
•
Carlsbad 13-0324
02/15/13
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Eric Jensen
PLAN CHECK NO.: 13-0324
DATE: 02/15/13
BUILDING ADDRESS: 2906 Roosevelt Street
BUILDING OCCUPANCY:
BUILDING AREA Valuation
PORTION (Sq.Ft.) Multiplier
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
----------------
Bldg. Permit Fee b Ordinance ....
Plan Check Fee by Ordinance
Type of Review: □ Complete Review
D Repetitive Fee ~ Repeats
" Based on hourly rate
Comments: 1 hour plan review.
□ Other
0 Hourly
EsGil Fee
TYPE OF CONSTRUCTION:
Reg. VALUE
Mod.
□ Structural Only
1-----1-'-IIHr. @ •
$86.00
($)
$107.501
$as.001
Sheet 1 of 1
macvalue.doc +
«~ ~ CITY OF
PLANNING DIVISION
BUILDING PLAN CHECK
APPROVAL
CARLSBAD P-29
DATE: 2/6/13 PROJECT NAME: SOLAR PANELS PROJECT ID:
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.car1sbadca.,mv
PLAN CHECK NO: CB130324 SET#: ADDRESS: 2906 ROOSEVELT ST APN:
~ This plan check review is complete and has been APPROVED by the PLANNING
Division.
By: GINA RUIZ
A Final Inspection by the PLANNING Division is required D Yes ~ No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check APPROVAL has been sent to: ASINK@SOLARCITY.COM
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING ENGINEERING FIRE PREVENTION
760-602-4610 760-602-2750 760-602-4665
□ Chris Sexton □ Kathleen Lawrence □ Greg Ryan
760-602-4624 760-602-27 41 760-602-4663
Chris.S~xtQn@carlsbadca.gQv K<!lhl!l!ln.Lawri1nce@~arlsbad~a.ggv Gregory.Ryan@carlsbm;!~a.gQy
□ Gina Ruiz □ Linda Ontiveros □ Cindy Wong
760-602-4675 760-602-2773 760-602-4662
Gina.Ruiz@carlsbadca.gov Llnda.Ontlveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov
□ □ □ Dominic Fieri
760-602-4664
Dominic.Fieri@carlsbadca.gov
Remarks:
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
06-20-2013 Plan Check Revision Permit No:PCR13086
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Reference #:
PC#:
2906 ROOSEVELT ST CBAD
PCR
Lot#: 0 2033040100
$0.00
CB130324
Construction Type: NEW
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Project Title: VERMILYEA OFFICE BLD-REVISE Inspect Area:
ELECT LOAD INVERTER AND LOAD CENTER LOCATION MOVED
Applicant:
ALEXANDRA SINK
5183 MERCURY PT
SAN DIEGO CA 92111
619-252-8429
Plan Check Revision Fee
Fire Expedited Plan Review
Additional Fees
Total Fees: $107.50
Inspector:
Owner:
GSD VERMILYEA
11620 KISMET RD
SAN DIEGO CA 92128
$107.50
$0.00
$0.00
Total Payments To Date: $107.50 Balance Due:
FINAL APPROVAL
Date: Clearance:
ISSUED
06/04/2013
LSM
06/20/2013
06/20/2013
$0.00
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020{a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fee~/nx::i,-tionc: of which "0'' have nrevini•sl" 1-.e"n niven a NOT!'"'E simil::ir tn thic: or as to whif'h thA statute nf limitations h"'" "reviousl" nth"rwise exnired.
«,
~ CITY OF
CARLSBAD
PLAN CHECK REVISION
APPLICATION
B-15
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
Plan Check Revision No. PC-R, \ '2., O ~ ICBJ30324 Original Plan Check No.-======'-----
Project Address 12906 Roosevelt St
Contact jAlexandra Sink I Ph j619-252-8429
Date I 6/04/2013
Fax _________ _
. !asink@solarcity.com
Email --=· =='-c=~==============:::;----------;:::::=::::::===~---;===::;---
Contact Address _,lc,,5=18=3=M=e=rc=u,,,;ry"=P=t ====='.----~ Cit)San Diego I Zip j92111
14.32 PV roof mount
General Scope of Work-'==========='-------------------
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1 . Elements revised:
ESrPlans D Calculations D Soils D Energy D Other ___________ _
2. 3.
Describe revisions in detail list page(s) where
each revision is
shown
jlnverter and load center location moved around corner I !Pg 2 I
New 125A load center installed, fed by 60A breaker in (E) 1 00A
main service panel. (4) 20A lighting loads rerouted from (E) main !Pg 5 I service panel to (N) load center to make room for 60A breaker
which feeds load center. PV backfeed is still 20A.
5.
6.
Does this revision, in any way, alter the exterior of the project? s' Yes
Does this revision add ANY new floor area(s)? D Yes
7. Does this revision affect any fire related issues? D Yes
8 .. Is this a compl"t?r O N:---
.€::SS1gnature ~---
~ No
[SJ' No
4.
list revised sheets
that replace
existina sheets
!Pg 2 I
IPg 5 I
0 No
1635 Faraday Avenue, Carlsbad. CA 92008 f!::t: 760-602-2719 Eax: 760-602-8558 Emait building@carlsbadca.gov
www.carlsbadca.gov
EsGil Corporation
In (Partnersfiip witfi qovernmentfor<Bui(tfing Safety
DATE: 06/18/13
JURISDICTION: Carlsbad
PLAN CHECK NO.: PCR13-086/13-0324
PROJECT ADDRESS: 2906 Roosevelt Street
SET II
PROJECT NAME: Vermilyea 3.6 kWatt Solar Photovoltaic System
□ APPLICANT
la"JURIS.
□ PLAN REVIEWER
□ FILE
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Alexandra Sink Telephone#: 619 252-8429
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person E-mail: asink@solarcity.com
0 REMARKS:
By: Eric Jensen
EsGil Corporation
□GA 0EJ □PC
Enclosures:
06/13/e-mail
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
EsGil Corporation
In <Partnersnip witn IJovernment for <Bui(ain9 Safety
DATE: 06/ 12/ 13
JURISDICTION: Carlsbad
PLAN CHECK NO.: PCR13-086/ 13-0324
PROJECT ADDRESS: 2906 Roosevelt Street
SET: I
g,APPLICANT
_p JURIS.
□ PLAN REVIEWER
□ FILE
PROJECT NAME: Vermilyea 3.6 kWatt Solar Photovoltaic System
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
D Esgil Corporation staff did not advise the applicant that the plan check has been completed.
~ Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Alexandra Sink Telephone#: 619 252-8429
Date contacted: \Jj\'2-(by:~) Fax #:
~ail Telephone Fax In Person E-mail: asink@solarcity.com
0 REMARKS:
By: Eric Jensen
EsGil Corporation
0 GA O EJ O PC
Enclosures:
06/06
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad PCR13-086/ 13-0324
06/12/13
GENERAL PLAN CORRECTION LIST
JURISDICTION: Carlsbad
0324
PROJECT ADDRESS: 2906 Roosevelt Street
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 06/06
REVIEWED BY: Eric Jensen
FOREWORD (PLEASE READ):
PLAN CHECK NO.: PCR13-086/ 13-
DATE REVIEW COMPLETED:
06/12/13
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and disabled access. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. The approval of
the plans does not permit the violation of any state, county or city law.
• Please make all corrections and submit two new complete sets of prints to:
ESGIL CORPORATION.
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
□ Yes □ No
Carlsbad PCR13-086/ 13-0324
06/12/13
ELECTRICAL and ENERGY COMMENTS
PLAN REVIEWER: Eric Jensen
ELECTRICAL (2010 CALIFORNIA ELECTRICAL CODE)
1. Correct the site signage detail.
2. Show the gate location on the site plan. If not located between the inverter and the
service, provide a AC disconnect.
3. I'm not sure how the existing permitted set coordinates with this revised set: The original
set appears to have had most of the service load on a remote subpanel fed from a 100
ampere breaker. The revision set has a 60 ampere breaker feeding the loadcenter that
feeds existing loads on a loadcenter? What happened to the original 100 ampere
panelboard?
Note: If you have any questions regarding this Electrical and Energy plan review list please
contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a
copy) where the corrected items have been addressed on the plans.
Carlsbad PCR13-086/ 13-0324
06/12/13
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
0324
PLAN CHECK NO.: PCR13-086/13-
PREPARED BY: Eric Jensen DATE: 06/12/13
BUILDING ADDRESS: 2906 Roosevelt Street
BUILDING OCCUPANCY:
BUILDING AREA Valuation
PORTION (Sq.Ft.) Multiplier
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
----------------
Bid , Permit Fee b Ordinance g y ...
Plan Check Fee by Ordinance ----~
Type of Review: □ Complete Review
D Repetitive Fee
_ -~ Repeats
□ Other
Q Hourly
EsGil Fee
* Based on hourly rate
Comments: 1 hour plan review.
TYPE OF CONSTRUCTION:
Reg. VALUE
Mod.
□ Structural Only
1-----1.:..il Hr. @ *
$86.00
($)
$107.50!
$as.001
Sheet 1 of 1
macvalue.doc +