Loading...
HomeMy WebLinkAbout2558 ROOSEVELT ST; ; CB901853; Permit.. B U I L D I N G P E R M I T --12/20/90 11:05 Page 1 of 1 IMPROVEMENT Class Code: Job Address: 2558 ROOSEVELT ST Permit Type: INDUSTRIAL TENANT Parcel No: 203-102-35-00 Valuation: 7,000 Construction Type: VN Occupancy Group: 82 Description: 494 SF OFFICE PESTKA, JOANN Str: * * Permit Project Development Fl: **** Ste: 75 1 No: CB901853 No: A~002119 No: 202B 01 Ol ~a S~~SSUED Applied: 11/26/90 Apr/Issue: 12/20/90 Validated By: DC Appl/Ownr : PRESIDENTIAL PLAZA 2558 ROOSEVELT ST #30 5 619 434-1742 CARLSBAD, CA 92008 ---- CONTRACTOR Fees Fees : Adjustments: Total Fees: Fee description Building Permit Plan Check INu.........-.~----- 1 CLEARANCE~...,,...~~~, CITY OF CARLSBAD 2075 Las Palinas Dr., Carlsbad CA 92009 (619) 438-1161 619-632-0332 .00 82.00 328.00 *** Ext fee Data 90,00 59 .00 1.00 245.00 Y 395.00 5.00 Y 10.00 REMODEL 15.00 ~-·· PERMIT APPLICATION ~ • City of Carlsbad Building Department EST. VAL &, /,i? D 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 PLAN CK DEPOSIT ~ ~ VALID. BY /'?t:.- 1. PERMIT TYPE OATE ,, a w9 a A • COMMERCIAL TENANT IMPROVEMENT □TENANT IMPROVEMENT • C 2. 0 INDUSTRIAL 0 RESIDENTIAL □DUPLEX PRO Address □NEW 0 APARTMENT □DEMOLITION □POOL □CONDO □SINGLE FAMILY Dl,IELL!NG □RELOCATION □MOBILE HOME □SPA □RETAINING l,IALL OsOLAR Nearest cross Streets Laguna 0 ADDITION/ALTERATION □PLUMBING LEGAL DESCRIPTION Lot No. Subdivision Narne/Nurber Unit Mo. Phase No. CHECK BEUM IF SUBJIIITTED: D 2 Soi ls Report ff1 Addressed Envelope 3. 4. 5. 1812 Energy Cales 02 Structural Cales ASSESSOR'S PARCEL 203-102-35 OtSCKitliiON m QOkk 494 sq.ft. of Tenant BLDG. SQ. FTG. CONTACT PERSON ""' Henry Tubbs CITY Encinitas SIGNATURE APPLICANT NAME Cl TY Henry Tubbs Encinitas PROPERTY OWNER JlcoNTRACTOR NAME Presidential Plaza ciTY Gar1 shad E)(1sT1NG usE Professional Office PRoPosED usE Sacre Irrq,rovenents, interior partitions and ceiling lights # OF STORIES STATE CA ADDRESS ZIP CODE 0 AGENT FOR CONTRACTOR ADDRESS STATE CA Z!P COOE 1991 Village Park Way, Suite 1/160 92024 DAY YELEPHONE 632-0332 O0IJNER □AGENT FOR OIJNER 1991 Village Park Way, Suite /1160 92024 DAY TELEPHONE 632::-0332 OIJNER □LESSEE OTEMANT ADDRESS 2558 Roosevelt Street, //305 STATE CA ZIP COOE 920)8 DAY TELEPHONE 434-1742 6. CONTRACTOR 7. 8. '"' Henry Tubbs c1TY Encinitas STATE CA. ADDRESS • 1991 Village Park Way, Suite //160 ZIP COOE 92024 DAY 1ELEPHONE632-Q332 638 CITY STATE LICENSE CLASS __ B ___ _ TITLE ADDRESS Z!P COOE CITY BUSINESS LIC. # _]()_80_300 _____ _ DATE DAY TELEPHONE STATE LJC. # WORKERS' COMPENSATION l.lorkers' Coq,ensat1on Declaration: hereby affirm that I have a certificate of consent to self-insure issued by the Director of Industrial Relations, or a certificate of Workers' Corr-.,ensation Insurance by an achitted insurer, or an eJ1act copy or dupt icate thereof certified by the Director of the insurer thereof filed with the Building Inspection 0epartment {Section 3800, Lab. C). INSURANCE COMPANY Golden Eagle Insurance C9'Ll)&JY POLICY No.w; 045787--02 Certificate of EJ1efl'f)tion: I certify that in the performance of the work for which th1s permit so as to become subject to the 1./orkers' c~nsation Laws of California. SIGNATURE DATE OWNER-BUILDER DECLARATION EXPIRATION DATE ] 2/Q] is issued, I shall not efl'f)loy any persoo in any manner Owner-Builder Declaration: I hereby aff1rm that I am e)(empt from the Contractor's License Law for the following reason: D I as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon,, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sate. If, however, the building or improvement is sold within one year of completion, the oi.ner-builder will have the burden of proving that he did not build or improve for the p...irpose of sale.). D !, as owner of the property, am eKclusively contracting with licensed contractors to construct the project {Sec. 7044, Business and Professions Code: The contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor{s) licensed p...irsuant to the Contractor's License Law). D I am ellempt under Section ___________ Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he \s licensed p...irsuant to the provisions of the Contractor's License Law (Chapter 9, cOIIJ!lencing with Section 7000 of Division 3 of the Business and Professions code) or that he is exefl'f)t therefrom, and the basis for the alleged ellemption. Any violation of section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500] ) . SIGNATURE DATE COMPLETE THIS SECTION FOR NON·RESIOENTJAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance AccoUtlt Act' □YES i8NO ls the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □YES ~NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □YES gJ,o IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE Of OCaJPANCY NAY NOT BE ISSUED AFTER JULT 1, 1989 UNLESS THE APPLICANT HAS MET OIi JS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 9. CONSTRUCTION LENDING AGENCY hereby affirm that there is a construction lending agency for the performance of the i.ork for which this permit is issued {Sec 3097(i) Civil Code). LENDER I S NAME LENDER'S ADDRESS 10. APPLICANT'S SIGNATURE ! certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State lai.s relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE JNDDINIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST All LIABILITIES, JWGMENTS, COSTS AND EXPENSES l,lffJCH MAY IN ANY \IAY ACCRUE AGAINST SAID CITT IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not conmenced within 180 days from the date of such permit or if the building or work authorized by such permit is susper,ded or abandoned at anY. ti~ tc, c.c wo:~i coomenced for a period of 180 days {Section 3D3(d) Uniform Building Code). APPLICANT'S s1 D OIJNER J81coNTRACTOR OeY PHONE APPROVED BY: _______ _ DATE: WHITE: File YELLOW: Applicant PINK: Finance ' •, PERMIT# CB901853 DESCRIPTION: 494 SF OFFICE CITY OF CARLSBAD INSPECTION REQUEST FOR 01/11/91 PESTKA, JOANN INSPECTOR AREA PD PLANCK# CB901853 OCC GRP TYPE: ITI JOB ADDRESS: 2558 ROOSEVELT ST APPLICANT: PRESIDENTIAL PLAZA CONTRACTOR: TUBBS, HENRY OWNER: REMARKS: MH/TRAVIS/943-9272 SPECIAL INSTRUCT: TOTAL TIME: CD 17 19 29 39 49 LVL DESCRIPTION ST Interior Lath/Drywall ST Final Structural PL Final Plumbing EL Final Electrical ME Final Mechanical ------------------ CONSTR. TYPE VN STR:** FL:**** STE: 202B PHONE: 619 434-1742 ::~::: 619~-;-3~ ;f/ INSPECToh'_~~-~H~~~-=-~----- ACT COMMENTS Afe, ic...___.___ ***** INSPECTION HISTORY***** DATE 122890 122890 122190 DESCRIPTION Interior Lath/Drywall Interior Lath/Drywall Frame/Steel/Bolting/Welding ACT INSP AP PD CO PD AP PD COMMENTS CHECK FEEDER SIZE RECEIVE u :_,_:; 1 13..,1 FIN~ING INSPECTION DEPT: BUILDING ENGINEERING / u PLANNING U/M PLAN CHECK#: CB901853 PERMIT#: CB901853 PROJECT NAME: 494 SF OFFICE PESTKA, JOANN ~.k--J.J() -f';' Le ADDRESS: 2558 ROOSEVELT ST SUITE~, CONTACT PERSON/PHONE#: MH/HENRY/632-0332 SEWER DIST: CA WATER DIST: CA WATER DATE: 01/11/91 PERMIT TYPE: ITI ====--==--===========---=----------------------------------------====--==---- INSPECTEDC BY: . (o o.Qcl < DATE INSPECTED: 1/1 '1 /91 APPROVED JL DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED --===================-------------------------------------------------------- COMMENTS: DATE: ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 0 Mrn;-~g~ JURISDICTION: ~AN CHECKER Q FILE COPY Q UPS !-DESIGNER PLAN CHECK NO: SET: IL PROJECT ADDRESS: zs~i RDO :.Cv'LLl PROJECT NAME: -re-,..) A--f.J7 1 1'/\e -·-' D D 0 D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified--=-----=-------------are resolved and checke d by building d e partment staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact pe rson. The applicant's copy of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has bee n completed. O Esgil staff did advise applicant that the plan check h as been completed. Person contacte d : ------------- Date contacted: _________ Telephone# ________ _ 0 REMARKS: _______________________ _ By : S y e:,,.,---. LL ,_✓,.,..,..,,.., vi-' r I Cc;;.e,,,,, Enclosures: ESGIL CORPORATION !Z/!f ----------- O GA □AA ORN ODM ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 l~ C ~ SAN DIEGO, CA 92123 4'1 I() 1f!!:3 (619) 560-14-68 I "l jP~ DATE: JURISDICTION: CARLSBAD QAPPLICANT ■JURISDICTION D PLAN CHECKER QFILE COPY QUPS QDESIGNER ___, PLAN CHECK NO: SET: -1- - PROJECT ADDRESS: 2 6s B l <-i21Js c vc.c1 LY ·-~re iJ-·U:Z8 PROJECT NAME: _ __,_1?-~~~j_/J_A-AI __ T __ I_-_;;,~~P ______ _ D D □ D fl The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified -=---c---------=--=---are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: 1-i-'CNf._'( liJ8:8>-' ' 1q11 V1LLA6 E f 11 f.. r £.J/1 'r =tr J&o. Ur C/2o'24- ~ Esgil staff did not advise the applicant contact person that plan check has been completed. O Esgil staff did advise applicant that the plan check has been completed. Person contacted: ------------- Date contacted: ---------Telephone# _______ _ □ REMARKS: __________________________ _ By: SY G--D I\ LC C--w\ ESGIL CORPORATION It/ 2) 0 'R.~ biJ.DM Enclosures: ----------- 90 -18 .-:;:3 PLAN CIEC1C NO.: _ __;_ ____________ _ ..JURISDIC'l'ION:---'CARI.SBAD===a.------------ ro:_-----'-/+f;_N_~_Y_Ti._U~B~B_< _____ _ OCCUPANCY: __ B_-_2-__________ _ BUILDING uSE: __ 1D_F_F--'-·1_c __ -e __ ; _s ______ _ TYPE OF OONSTRDCTION: \} -,J -----------,---- A CIUAL AREA: __ t.l-:..._1_,_4,;--'---S_f_. (..__f _I._· _0-IJ_L'f---,,].____ 7 ALLOWABLE AREA: ________________ _ Sl'ORIES: ____ 1.---____________ _ BEI<m: ___________________ _ Ye s SPRINKLERS: __________________ _ OCCUPANT LOAD: ________________ _ REMARKS: ___________________ _ Date plans received by jurisdiction: Date plans received by Esgil Corporation: Date initial plan check completed: _/_l .__I ~__._,_1D ___ .By:_S '_Y6:D __ A-t.._,C:_-c:_1'-1_ Applicant contact person: tt£-,J ~ y 'fl.} .fsE _s Tel. (p 8 2., '() ? 3 2.--------------· Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building I nspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. based on the 1988 UBC. Code sections cited are The circled items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations . Per Sec. 303(c), 1988 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, specification. etc. Be sure to enclose the marked up list when you submit the revised plans. NOIE: PAGE J«.mERS ARE NOT IN SF.QUENCE AS PAGES HAVING NO rnJ1S HEEDING CORREC'rIONS WERK DELEI'ED. LIST NO. 56 CARLSBAD TENANT IMPROVEMENT WITHOlIT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1988 UBC G I· )· ;- /- l !· I· Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-1468. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction1 s building department. Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. Section 302(d). · · Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. Plans and calculations shall be signed by the califomia state licensed engineer or architect where there are structural changes to existing buildings or structural additions. Please include the california license number, seal, date of license expiration and date plans are signed. Business and Professions Code. Provide the correct address and suite number of tenant space on the plans. Section 302{d). Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled. Section 302. When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy. Please provide complete details to show the building with comply. Section 502. UBC Section 304 requires .the Building Official to detemine the toU.l value of all construction work proposed under .. this pemit. The value shall include all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment. Please provide a signed copy of the designer's or contractor1s construction cost estimate of all work proposed. Provide a plot plan showing the distance from the building to the property lines and the location of tenant space (or remodel) within the building. 12/29/89 +· I 19. ~o. On the first sheet of the plans indicate: Type of construction of the existing building, present and proposed occupancy classifications of the remodel area and the occupant load of the remodel areas and the floor where the tenant improvement is located. Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in IJBC Tables 9-A and 9-B. A complete description of the activities and processes that will occur in this tenant space should be provided. A listing of all hazardous materials should be included. The materials listing should be stated in a form that would make classification in Tables 9-A and 9-B possible. The building official may require a technical report to identify and develop methods of protection from hazardous materials. Section 90l(f). If control areas are used for exceeding the exempt amounts of ha?.ardous materials from Tables 9-A and 9-B, they shall be constructed of not less that required for a one-hour occupancy separation. Section 404. The number of control areas within a building used for retail/wholesale stores shall not exceed two; the number of control areas in buildings with other uses shall not exceed four. Footnote 1, Tables 9-A and 9-B. The aggregate quantity of any hazardous materials "in use" and 11in storage" shall not exceed the quantity listed in Tables 9-A and 9-B for 11storage11 • Footnotes 2 and 3, Tables 9-A and 9-B. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1988 UBC, IJMC and UPC and 1987 NEC. Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or altered. Draw the plans to scale and indicate the scale on the plan. Section 302(d). Indicate the use of all spaces adjacent to the area being remodeled or improved. Show any existing fire rated area separation walls, occupancy separation walls, demising walls, shafts or rated corridors. Identify and provide construction details for proposed new fire rated walls. Specify on the plans the fire assemblies to protect proposed existing or new fire walls. ratings of openings in 2 ,-------------·-· I 24. I ! f· Identify existing walls to be removed, existing walls to remain and proposed new walls. Identify bearing walls, non-bearing walls, and shear walls. Provide a partitions, section Show: view of all new interior Type, size and spacing of studs. gauge for metal studs. manufacturer and approval indicate "to be ICBO approved". Indicate Specify number or Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load). Wall sheathing material and details of attachment (size and spacing of fasteners). Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. Provide notes and/or details to show that the floor and wall finish in toilet rooms are surfaced with a smooth hard non-absorbent material extending five inches up the wall. Similar surfacing shall be provided on the walls from the floor to a height of 4 feet around urinals and within water closet compartments. Section SlO(b), Note on the plans: 11All interior finishes must comply with Chapter 42 of the UBC", Specify "Class, _____ .flame spread rating (minimum) for _____________ ." Lateral bracing for suspended ceiling must be provided. (UBC Table 23-P) Where ceiling is not supporting interior partitions, ceiling bracing shall be provided by four No, 12 gauge wires secured to the main nmner within 2 inches of the cross runner intersection and splayed 90 degrees from each other at an angle not exceeding 45 degrees from the plane of the ceiling. A strut (adequate to resist the vertical component from -lateral loads) fastened to the main runner shall be extended to and fastened to the structural members o:f the roof or floor above. These horizontal restraint points shall be placed 12 feet o.c. in both directions with the first point within 6 feet of each wall. Attachment of restraint wires to the structure above shall be adequate for the load imposed. UBC Standard 47-18. 2/15/90 2 • t· @ I ~2- ® I rs, In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and floor above so that no concealed space exceeds 1,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 3,000 s.f. and 100 L.F.). Section 2516(f). In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and roof above so that no concealed space exceeds 31000 s.f. and no horizontal" dimension exceeds 60 L.F. (if space has sprinklers1 then 9,000 s.f. and 100 L.F.), Section 2516(fJ, Storage areas exceeding 1000 sq. ft. in connection with wholesale or retail sales shall be separated from the public area by a one-hour occupancy separation. If the entire building has an automatic sprinkler system, then the occupancy separation need not be provided. An automatic sprinkler system shall be installed in rooms used by the occupants for the consumption of alcohol and in accessory uses where the total area of such unseparated rooms and assembly uses exceeds 5000 square feet. Section 3802(c). The tenant space and new ar.d/or existing facilities serving the remodeled area must be accessible to ar.d functional for the physically disabled. See the attached correction sheet. Title 24, Part 2. The width of the required level area on the side into which doors swing shall extend 24 inches past the strike edge for exterior doors and 18 inches past the strike edge for interior doors. Section 2-3304, Title 24. Specify lever-.type hardware for passage doors on floors accessible to the disabled. Section 2-3304, Title 24 .• If both sexes will be employed and the number of employees exceeds four, provide separate toilet facilities for men and women. If 11both sexes will be employed and the total number of employees will not exceed four", and only one · restroom is provided, note the words in quotation above on the floor plan. Section 705. In areas where the occupant load exceeds --• two exits are required. See _______ _ Table 33-A.· 3 39. 41. i r· 8 I i5· r· Provide an exit analysis plan (may be 8 1/2" x 1111 or any convenient size). Exits should have a minimum separation of one- half the maximum overall diagonal dimension of the building or area served. Section 3303(c). The maximum number of required exits and their required separation must be maintained until egress is provided from the structure. Section 3303(a), Rooms with more than. 10 occupants exit through ~ adjoining room. to comply. Section 3303(e). may have 2.0!! Revise exits Exit signs are required for exits serving an occupant load exceeding 49. Show all required exit sign locations. Section 3314(a). Show that exits are lighted with at least one foot candle at floor level. Section 3313(a). Show the locations of existing exits from the building and show the path of travel from the remodel area to the existing exits. Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge". In lieu of the above, in a Group B occupancy, you may note "Provide a sign on or near the exit doors reading THIS DOOR TO RE2'IAIN UNLOCKED DURING BUSINESS HOURS", 'ibis signage is only allowed at the main exit. Section 3304(c). Exit doors should be a ml.111.IDWD size of 3 feet by 6 feet 8 inches with a minimum door swing of 90 degrees. Maximum leaf width is 4 feet. Section 3304(£). t?/tf¼J 7Jf1+T ~"ft."( /AJ./t-'f ~ I/ '3;S TI e, V l E: I <,. 3Go " C.t..Ef>rl!-t»-t I? Tl+ Exit doors should swing in the direction of egress when serving an occupant load of 50 or more or when serving any hazardous area. Section 3303(b), Applies to door(s), ___ _ Regardless of occupant load, a floor or landing not more than 1/2 inch below the threshold is required on each side of an exit door used for disabled access (may be 111 maximum where not used for disabled access). Section 3304(i), Doors should not project more than 7 inches into the required corridor width when fully opened, nor more than one-half of the required corridor width when in any position. Section 3305(d). Revolving, sliding and permitted as exit doors exceeds 9 or the exit area. Section 3304(h), overhead doors are not if the occupant load door serves a hazardous 2/14/90 55. 56. I Exit doors from assembly rooms with 50 or more occupants shall not be provided with a latch or lock Wlless it is panic hardware. Section 3318, Double acting doors are not allowed when serving a tributary occupant load of more than 100, or when part of a fire assembly, or part of smoke and draft control assemblies or when equipped with panic hardware. Section 3304(b). Corridors must provide continuous protection to the exterior of the building. Interruptions by an intervening room is not permitted: Foyers, lobbies or reception rooms constructed as required for corridors are not considered intervening rooms. Section 3305. Corridors and exterior exit balconies serving 10 or more occupants must be a minimum 44 inches wide and 7 feet high to the lowest projection. Corridors serving less than 10 occupants must be a minimum of 36 inches in width. Section 3305(b). When two exits are required, dead end corridors and exit balconies are limited to 20 feet. Section 3305(e). 30 or more occupants shall Corridors.serving have walls and construction except: ceilings of one-hour '-! Corridors greater than 30 feet wide when the occupants have an exit independent from the corridor. Exterior sides balconies. of exterior exit Corridor walls and ceilings need not be of fire-resistive construction within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sprinkler system throughout and smoke detectors are installed within the corridor in accordance with their listing. Section 3305 (g). Section 3305(g), Exception S, cannot be used for non-rated corridors in a fully sprinklered office space if the occupant load in the space exceeds 100. Section 3305(g), Exception 5 does not apply to co1I1Don corridors where the corridor serves as an exit for non-office areas (manufacturing, warehouse, etc.). )!.: 0 y I· EL.Eg:RICAL · Submit plan showing location of all panels. Submit panels schedules. Submit electrical load calculations o...i ?At.Je:t.. -,,c,-.,e&>ut..£. Indicate existing main service size. Indicate existing total main service load. Indicate new additional loads. Indicate wiring method, i.e. Fli'I, metal flex. Show exit signs on the electrical lighting plan(s). As per Section 3313 and 3314 of the 1988 UBC, provide two sources of power to exit signs and exit illumination. Provide receptacle(s) within 25' of the roof mounted A/C units. UMC Section 509. Provide multiple switch lighting controls per Title 24, 2-5319. Provide an electrical plan for the alarm system showing compliance with criteria described under earlier correction number 54. Provide mechanical ventilation in all rooms capable of supplying a minimum of 5 cubic feet per minute of outside air with a total circulation of not less than 15 cubic feet per I minute per occupant. Section 605 and 705, UBC. Provide mechanical plans showing existing and proposed HVAC equipment, ducts and access to f. equipment. I- /4. I Det.ail access and working clearances to HVAC equipment. Cooling coils or cooling units located in attic or furred space, where damage may result from condensate overflow, shall be provided with an additional water tight pan of corrosion resistant material to catch overflow if primary condensate drain becomes clogged. Section HOS, IJMC. One-hour corridors shall not be used as an integral part of a duct system. Dtis includes the space above a dropped ceiling within the one-hour corridor. UMC Section 706{b). PUJKBIJIG Provide gas showing pipe Section 1219. line plans and calculations, lengths and gas demands. UPC 2/14/90 ELECT. □vw ~§~ DATE 12,..3•<::f6 4 19. 9( J. I. ( I- I Provide drain, waste and vent plans. Provide water line sizing calculations. UPC Section 1009, Detail how floor drain trap seal is to be maintained. UPC Section 707 (floor drain trap priming). Show P & I valve on water heater and detail drain line route from P & I valve to the exterior. UPC S~ction 1007(e). Show 1/411 per 1211 slope on drain and waste lines. IJPC Section 407. Provide a drinking fountain at each floor level in assembly occupancies (except drinking and dining establishments). UBC Section 605. Provide cocrplete energy design calculations1 including all existing design and new energy design for this building. See attached non- residential energy design checklist. For remodels in an existing conditioned space, show that the remodeled space will use not more energy than the existing space or show the remodeled space will conform to latest energy design standards. 96. Please see additional corrections or remarks that follow. 97. To speed up the recheck process, note on this list (or a copy) whee each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 98. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. ____ Yes _____ N.o Fiui4 r:iA11\J !;:ee,,11c£. ro suBf'ANEL, ](pA. \.o.Ji-lAT '?A>-IE-L. sueei..ies t,.,C<.1£~ J:t'.> E.Xt$/ING h'VM'-//NIT°; TGN4NT NU .2¥-.14-( b) ,. M PE OGA □AA DATE □-- 6 The minimum rating of a service discoMect is 100 amperes. The minimum size conductor to receptacles and lighting fixtures in commercial and industrial buildings shall be #12 CU. AC(BX) cable is not allowed in group A, B, E, H and I occupancies. (see Ord. for exception) Please see that follow. additional corrections or remarks Q To speed up the recheck process, note on this ~ list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. IIO'l:E: Please indicate here if any changes have beeh made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been resulting from this check. made to the plans not correction list? Please ____ Yes ____ ...1No The following provisions are contained in Title 24, Part 2, california Building Code, as adopted and enforced by the State Fire Marshall. They are provided here as a courtesy to assist designers in developing the project documents. All applicable provisions may not necessarily be included. Please direct any 9uestions regarding interpretations of these provisions to the local Fire Department. sf 1. Walls of corridors and exterior exit balconies in Groups A,E,I,R-1 and C Occupancies having an occupant load of more than six persons and in all.other occupapcies having an occupant load of 30 or more shall be not less than one-hour fire-resistive construction. Section 3305(g)l. Where exit signs are •.. required by Section 3314(a), approved and listed internally, externally or self-illuminated.low-level exit signs complying with Section 3314 shall be required. The bottom of the sign shall be not less than 6 inches nor more than 8 inches above the floor level. For exit way doors, the sign shall be on the door with the closest edge of the sign with 4 inches of the door frame or adjacent to the door. Such signs shall be of a type which is perceptible to the sense of touch. Section 3314(e). 2 28/90 Where exit signs are required by Section 3314(a), all exit corridors shall be provided with continuous low-level exit path marking. Approved and listed internally or self- illuminated marking shall be installed at floor level or no higher than 8 inches above the floor level. Such marking shall be of a type which is perceptible to the sense of touch. Section 3314(f). Area separation walls shall not be considered to create separate buildings for the purpose of automatic fire-sprinkler system requirements as set forth in Chapter 38. Section 505(e)6. EXCEP'l'ION: Buildings separated by continuous area separation walls of four-hour fire- resistive construction without openings. Buildings required to have atrtomatic fire- sprinkler protection as set forth in Section 13113 of the Health and Safety Code (homes for children or the aged) are prohibited from using area separation walls in lieu of automatic fire-sprinkler protection. In educational occupancies, storage and janitor closets shall be of one-hour fire- resistive construction with openings protected by assemblies having at least a three-fourths- hour fire-resistive rating. Section 802(c). Section 1807 should be reviewed for all high- rise buildings. The exception in Section 3318 of the UBC has been revised so as to allow the omission of panic hardware at the main exit in churches (by using signage), only when the occupant load of the church is less than 300. If emergency warning systems are required, they shall activate a means of warning the hearing impaired. Flashing visual warnings shall have a frequency of not more than 60 flashes per minute. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, califomia 92123; telephone number of 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact. ________ _ s y €1) A-t-£:C,,v1 at Esgil Corporation Thank you. Enclosures: l.. ___________________ _ 2 •. ______________________ _ 7 PHYSICALLY HANDICAPPED ACCESS REQUIREMENTS FOR REHODELS llncludln9 alterations, structural repairs, additions, tenant iaproveaents and.occupancy changes) A. GENERAL Full access c0111pllance is required for remodel& including: 1. Path of travel to relDOCleled area. la) Parkln9 lb) Walk• (c) Hazard• (di Curb Raiaps (e) Ra11ps (!) Elevator• 2. Priaary entrance to remodeled area. (a) Entnncea lb) Exit Door• J. Sanitary fac111t1e• serving remodeled area. ~-Drinking fountains and telephones serving reinodeled area. B. ADtODELS LESS THAN $ 6.9,291 f When reaodel• are valued at less than ;69,291 acce•• compllanco MY be limited to the speciClc area being rent0doled when an un- reasonable hardship ls deter•ined by the enCorcing agency. 1. Staff determination oC unreasonable hardship shall bo anade on For• IICA-1, vhich shall be filed in tho project Ule. 2. When the req~lred work outside of the relllOdeled area (1.a through l.'f above} exceeds 101 of the cost of the work to be done ln the relftOdeled area, an unreasonable hardship shall ~e found to exist (criteria i ■ ■taff 9uldellne). 3. The unreasonable hardship finding llBY be by observAtion vhen obvious. Form IICA-1 should describe the obvious. C. REMODELS $69,291 and IIICIIER When re1110dels are valued over$,69,291 and specific access requirements cannot be met: 1. The lav allovs equivalent facilities to be accepted if atrict co•pliance vlth the re9ulations vould create an unreasonable hardship. 2. Access cannot be waived unless there arc physical or legal barriers that .prevent providln9 either full access compliance or equlv~lent lacltitation compliance. When both access and equivalent Cacllitatlon are waived by the enforcement offici~l, ratlflcatlon ls required by an Appeals Board. D. HULTI-FLOOR REHOOELSz Exceptions and exemptions 1. Provisions for u.pper and Lover floorst The Health and Safety Code Section 19955.5 says that,•1n privately• funded multi-storied passenger vechicle service stations, shopping centers, offices of physicians and surgeons, and office buildings, subject to this code, floors or levels above and below the first floor or ground level are exe•pt from these requirements if a ramp or elevator ls not available to provide public access to such Cloors or levets.• 2. llealth and Safety Code Section 1'956 says that,•1n privately-funded fflUltl-storied buildings, Cloors or levels above the first floor or gr~und level are exempt fro,11 these requirements it a reasonable portion oC all facilities and acconvnodations normally sought and used by the public in such a building arc accessible to and usable by physically handicapped persons.• • REMODEL OR TENANT IMPROVE:-tENT CONSTRUCTION VALUATION The Building Official is mandated by State law to determine the value of work proposed in each application for a Building Permit. The value to be used, shall be the total value of all construction work for which the permit is issued as well as all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevators, fire exting- uishing systems and any other pe=~anent equipment. Uniform Building code Section 304 (al *********************************************************************** APPLICANT PLEASE COMPLETE SITE ADDRESS 2558 Roosevelt Street, 11202B PLAN CHECK NO._;;._;90-:......:.;18=5~3 __ _ DESCRIPTION OF PROPOSED WORK Interior partitions, suspended ceilipg, convenience outlets, tele!'lone jacks and lights. AREA OF 0 REMODEL. ________________ _ . [!) TEN.".NT IMPROVEM:::NT 494 square feet D ADDITION -----------------PROPOSED WORK INCLUDES: NEW SUSPENDED CEILING NEW HVAC NEW FIRE SPRINKLERS NEW PARTITIONS NEW PLUMBING NEW ELECTRICAL HAS A CONTRACTORS ESTIM.".TE BEEN RECEIVED ITEMIZED COST ESTIMATE IS ATTACP.ED [~] 0D YES DYES DYES OD YES DYES 0D YES FOR THE PRO?OSED WORK?[ YES [X] NO ]YES(X]NO I CERTIFY THE VALUE OF ALL PROPOSED CONSTRUCTION WORK COVERED BY THE PERMIT APPLICATION INCLUDING: ALL STRUCTURAL WORK, FINISH W , ING, ROOFING, ELECTRICAL, PLUMBING, HEATING, AIR CONDIT! NG, ELEVAT .S, FIRE EXTINGUISHING SYSTEMS, AND ALL PERM.".NENT EQUIPMENT IS:$7,ooo.oo THIS VALUE IS BASED ON: 0 DESIGNER'S ESTIM.".TE w· CONTRACTOR'S ESTIM.".TE 0 OTHER, DESCRIBE BASIS _____________ _ :UE I~O~S TRUE AND CORRECT -(7T ? -' 1~~ _:_1_2----1-1fa_1_0+-,/2...:.r,...:o __ D D [TI APPLICANT DESIGNER CONTRACTOR ********************************* *********** *********************** PLAN CHECKER USE ONLY THE VALUE IS ACCEPTABLE YES AN ITEMIZED COST BREAKDOWN IS REQUI CONSTRUCTION VALUE. 0 YES CO IRM THE ESTIMATED BY:~-z._~:::::-;;;,'-__::__ _____ _ DATE: ________________ _ 4/22/85 / Dates ii/':> Jurisdiction CARLSBAD Prepared by1 SYE:D ~ VALUATION AND PLAN CHECK FEE □ Bldg, Dept. O Esgil PLAN CHECK NO, 1D--tir~ BUILDING ADDRESS Z.s<: 'i? /?J.;fJJCI/CLT Sr ~--:µ 20ZB APPLICANT/CONTACT (1!Nf{ Y 7Ub8 (,: PHONE NO, ______ _ BUILDING OCCUPANCY /;) · 2-DESIGNER PHONE TYPE OF CONSTRUCTION V-,J CONTRACTOR PHO._N_E ____ _ BUILDING PORTION BUILDING AREA VALUATION VALUE MULTIPLIER ?e,J/JMJT unt> l/1 cf z_o·~u 10, z. 7 .. . Air Conditionin~ l:!ommerc1al @ . Residential ta ./"I rt) Res. or Comm. Io ..---7 Fire S'Drinklers @ Total Value A1' , u?! Building Permit fee $ _________________ __,._/_2-_C,, _____ _ ~ r .tJ. .~z $ /2/'q[) Plan Check fee $ /:.,,'.-4/L, (,[-::.---rG5 V CO H HEN TS,'-•---------------------------- SHEET OF __ _ PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB 90-; (5' ..3 DATE ___ ~~/2_.;;_~_/_,9_a ___ _ ADDREss ~d<-'-5._5_<o __ ?.?~"'-""-<;'_ .. _~_~_t_r __ ,,....ffi~~~~o~-------- RESIDENTIAL RESIDENTIAL ADDITION MINOR ( < $10,000.00) PLAZA CAMINO REAL VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER ________________________ _ PLANNER _U_._L_,y'-'II_G_',<_ _______ DATE //-2-7-f 0 ENGINEER C_ , We.o. & \.JI.::",. DATE //-2.7,C,o C:\WP51 \FILESIBLDG.FRM Rev 11 /15/90 2560 ORION WAY CARLSBAD, CA 92008 <!(tp of ctearlsbab FIRE DEPARTMENT PAGE 1 OF _ TELEPHONE (619) 931-2121 APPROVED DISAPPROVED PLAN CHECK REPORT PLAN CHECK# _ __.,....;_;_;;-'--"-..:....__;_____;__.:_-r....;1.:::......r...fi>---=._,_..:...._,"--'-'--.ADDRESS .2. -rrr ~ _.....:....c'....'...!........:.........:.,;_J...:....~.:::._-------ADDRESS I J, V~i lfl, PHONE -----'-- OWN ER -----'-~.c..:...:.~_..:."--....:.......L,;.... ______ ADDRESS _,__ __ J?,..:.....:y:..__..;;__..::....:...' ....:.....r __ PHONE / .... l./ I I. j OCCUPANCY -'-------CONST. _.\/c..:...1 ....... A=/,:__ __ TOTAL SQ. FT. _Y-4-f ___ rfi __ 0 SPRINKLERED .□ TENANT IMP. __ A_.4_......,.....tJ,___ _______________________ _ STORIES APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS: PLANS, SPECIFICATIONS, AND PERMITS __ 1. Provide one copy of: floor plan(s); site plan; sheets ____________________ _ __ 2. Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project. __ 3. Provide specifications for the following: __ 4. Permits are required for the installation of all fire protection systems (sprinklers, stand pipes, dry chemical, halon, CO2, alarms, hydrants). Plan must be approved by the fire department prior to installation. __ 5. The business owner shall complete a building information letter and return it to the fire department. L a. _L 1. __ a. y __ 9_ __ 10. __ 11 . FIRE PROTECTION SYSTEMS AND EQUIPMENT The following fire protection systems are required: D Automatic fire sprinklers (Design Criteria: ~---i~/~~>-i~·------------------0 Dry Chemical, Halon, CO2 (Location: _____________ ;__ ___________ _ D Stand Pipes (Type: -------------------------------- □ Fire Alarm (Type/Location: ____________________________ _ Fire Extinguisher Requirements: Q--One 2A rated ABC extinguisher for each ____ sq. ft. or portion thereof with a travel distance to the nearest extinguisher not to exceed 75 feet of travel. □ An extinguisher with a minimum rating of ___ to be located: □ Other: ___________________________________ _ Additional fire hydrant(s) shall be provided ------------------------ EXITS Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. A sign stating, " This door to remain unlocked during business hours" shall be placed above the main exit and doors ------------------------------------ EXIT signs (6" x ¼" letters) shall be placed over all required exilts and directional signs located as necessary to clearly indicate the location of exit doors. GENERAL __ 12. Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and hazardous chemicals shall comply with Uniform Fire Code. __ 13. Building(s) not approved for high piled combustible stock. Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids. If high stock pil- ing is to be done, comply with Uniform Fire Code, Article 81. __ 14. Additional Requirements. ------------------------------ A. , .7 I -r:1 h. __ 15. Comply with regulations on attached sheet(s). Plan Examiner ____ :........:._....:..... _____________ _ Dal8------':..__ _____ _ Report mailed to architect ___ Met with ___________ , ___ _ __ Attach to Plans 0 cr-. a COHHERCIAL/INDUSTRIAL APPLICATION fORH fOR INDUSTRIAL WASTE DISCHARGE PERHIT CITY Of CARLSBAD APPLICATION: (CHECK ONE ) NEW X ------ REVISED BY: __ ~~""""'"'..,._...__....lA....,kUl __ .,):<A..,__.. ___ _ Signatur9Y City Representative BUILDING P.C . NO.: 90-)~~ APPLICATION NO. :_7._.8__,.J __ _ INDUSTRI AL CL ASS: 3/ ----":.-.. __ _ DATE: l2,-J ·9D APPLICATION FOR INDUSTRIAL WASTE DISCHARGE PERMIT A. G£NERAL: SITE APPLICANT : PRESIDENTIAL PLAZA AOORESS: 2558 Roosevelt Street, 11202B TYPE Of BUSINESS: Credit Check i n g -General Office APPLICANT'S ftDORESS: 2558 Roosevelt Street, 11305 , Carlsbad 8. WASTES AND PROCESSING : (Check where applicable ). l~I Domestic Waste Only 1:1 Industrial Waste 1:1 Industrial Waste NOT Di scharged to Sewer Discharged to Sewer GENERAL DESCRIPTION Of WASTE (Chemi cal and Physical Characterist ics o f proposed waste ): -------------------------- GENERAL DESCRIPTION Of PROCESS (If Appli cable): ------------ C. WASTES TO i3E DISCHARGED TO SEWER: WASTE: (Check One ) TREATED : UN TREAT ED_,...:_x __ QUANTITY: AVERAGE 494 Square Gl>Det (Daily) MA XIMUM ....--....---..,-GPO (G allons Per Day ) APPLICANT OR REPRESENTATIVE Of FIRM : Henry T ubb s _________ (,_P_r_i_n_t.,...) ______ _ TITLE: Aten t ~~ SIGNATURE: ~ T~ DATE : 11/26/90