Loading...
HomeMy WebLinkAbout1424 SAPPHIRE DR; ; CB973674; PermitB U I L D I N G P E R M I T 12/29/97 13:59 Permit No: CB973674 Project No: A9704751 Development No: DEV89133 Page 1 o.f 1 Job Address: Suite: Permit Type: SINGLE FAMILY DWLNG -DETACHED Parcel No: -2 1 ~ 14.:> tJ ,o"O Lot#: 7 Valuation: 213,979 Construction Type: VN ISSUED 11/24/97 12/29/97 RMA Occupancy Group: Reference#: CT84-32 Status: Description: PLAN 7,PHS 1,2570+577 GAR+'51-5-Applied: : g.eef{,COBBLESTONE,GREYSTONE HOMES Apr/Issue: Appl/Ownr : GREYSTONE HOMES 495 E RINCON STE 100 CORONA CA 91719 Plan Check Numbers > ORIG Entered By: 909 273-9494 971300 PC973614 *** Fees Required *** *** Fees Collect~d & Credits *** ----------------------25=?~-izr29f~0001-01.--~--- Fees: Adjustments: Total Fees: Fee description 16,312.79 .00 16,312.79 Number of Bedrooms Number of Bathrooms Building Permit Plan Check Strong Motion Fee Enter Park-in-Lieu Acct#(9) Enter "Y" to Autocalc P .F.F. Enter "Y" to Autocalc T.I.F. Payoff Fee for CFO * BUILDING TOTAL Enter #Units & Code-Potable Water> Enter "Y" f or Plumbing Issue Fee > Each Plumbing Fixture or Trap > Each Building Sewer > Each Install/Repair Water Line > Each Water Heater and/or Vent > Gas Piping System > Each Vacuum Breaker > * PLUMBING TOTAL Enter "Y" for Electric Issue Fee > Single Phase Per AMP > * ELECTRICAL TOTAL Enter 'Y' for Mechanical Issue Install Furn/Ducts/Heat Pumps Each Install Fireplace Each Exhaust Fan Each Install/Reloc Vent * MECHANICAL TOTAL Construct Housing(Y/N)? Enter Impact Fee Fee> > > > > > > Total Credits: Total Payments: Balance Due: Units Fee/Unit 1 16 1 1 1 1 2 125 2 1 1 2 2925 7.00 15 .00 7.00 7.00 7.00 7.00 .25 9.00 6.50 6.50 4.50 c-PRMT 16312-79 .00 .00 16,312 .79 Ext fee Data 5 .00 2.50 1039.00 675.00 21.00 1575.00 2 3894.00 Y 540.00 Y 2965.79 10709.79 2400.00 D5/8 20.00 Y 112.00 15.00 7.00 7.00 7.00 14.00 182.00 10.00 Y 31.25 41.00 15.00 Y 18.00 6,50 6.50 9.00 55.00 N 2925,00 FINAL APPROVAL INSP~~ic.-<-DATE.l:J.L..1.L. CITY OF CARLSBAD INSPECTION)3~QUEST PERMIT# CB973674 FOR 06/V-1/98 DESCRIPTION: PLAN 7,PHS 1,2570+577 GAR /~ COBBLESTON~GREY TONE HOMES TYPE: SFD I Lf 1-.. 4--p R. JOB ADDRESS: 0 APPLICANT: GREYSTONE HOMES CONTRACTOR: OWNER: PHONE: PHONE: PHONE: INSPECTOR AREA PY PLANCK# ORIG 971 OCC GRP CONSTR. TYPE VN STE: LOT: 7 909 273-9494 REMARKS: C/BRAD/603-0056 SPECIAL INSTRUCT: INSPECTOR ---~/l)_'~IF'------- TOTAL TIME: CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical l-- ------------------------------------------------------ ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 052698 Final Electrical NR PY NO SUPER 052698 Final Electrical NS PY 052698 Final Electrical PA PY EMR 052198 Final Electrical NS PY 052198 Final Electrical PA PY EMR 042098 Interior Lath/Drywall AP PS 041398 Drywall/Ext Lath/Gas Test AP PY 040998 Interior Lath/Drywall AP PY 040998 Exterior Lath/Drywall NR PY 040998 Gas/Test/Repairs AP PY 040898 Interior Lath/Drywall AP PY 040898 Exterior Lath/Drywall NR PY 040898 Gas/Test/Repairs NR PY 032598 Rough Combo AP PY 031898 Shear Panels/HD's AP PY 030998 Roof/Reroof AP PY 012098 Ftg/Foundation/Piers AP PY 011998 Ftg/Foundation/Piers CA PY 011698 Ftg/Foundation/Piers NS PY 010798 Underground/Under Floor AP PY DEPT: BUILDING FI~~ING INSPECTION · ENGINEERING ~ PLANNING CMWD ST LITE PLAN CHECK#: CB973674 PERMIT#: CB973674 PROJECT NAME: PLAN 7,PHS 1,2570+577 GAR COBBLESTONE,GREYSTONE HOMES ADDRESS: 0 \~ '2-\.\ ~~~"~""_,"'t::)~ CONTACT PERSON/PHONE#: C/TREY/603-0056 SEWER DIST: WATER DIST: Lot# 7 DATE: 06/02/98 PERMIT TYPE: SFD .._If J~i -1998 ========---======----------=-================================================ INSPECTED BY: INSPECTED BY: INSPECTED BY: DATE INSPECTED: tt//~/7}---APPROVED ~ DISAPPROVED DATE INSPECTED: ___ APPROVED DISAPPROVED DATE INSPECTED: APPROVED DISAPPROVED -----------===-=-------------================================================ COMMENTS: FINAL BUILDING INSPECTION ~--- DEPT: BUILDING ENGINEERING IRE PLANNING CMWD ST LITE PLAN CHECK#: CB973674 PERMIT#: CB973674 PROJECT NAME: PLAN 7,PHS 1,2570+577 GAR COBBLESTONE,GREYSTONE HOMES ADDRESS: 0 \"-Ii.. '4."-\ "::)~~\:.,._, ~-- CONTACT PERSON/PHONE#: C/TREY/603-0056 SEWER DIST: WATER DIST: INSPECTED . BY: INSPECTED BY: DATE fill-,,._ INSPECTED:~ DATE INSPECTED: DATE INSPECTED: Lot# 7 DATE: 06/02/98 PERMIT TYPE: SFD Jl.J1~ -2 1r , 7-:~============== APPROVED__ DISAPPROVED_ APPROVED DISAPPROVED APPROVED DISAPPROVED ===============-===-======-=================================================: COMMENTS: DEPT: BUILDING FINAL BUILD~NS-PECTION ENGINEERING FI✓ A .LANNING CMWD ST LITE PLAN CHECK#: CB973674 PERMIT#: CB973674 PROJECT NAME: PLAN 7,PHS 1,2570+577 GAR COBBLESTONE,GREYSTONE HOMES ADDRESS: 0 \'-I\. "2-.'-\ '5~~\~..-~ ... :"t:).- CONTACT PERSON/PHONE#.: C/TREY/603-0056 SEWER DIST: WATER DIST: Lot# 7 DATE: 06/02/98 PERMIT TYPE: SFD ===============-============--=============================================== INSPECTED V½2 DATE G,-~C,6 BY: INSPECTED: APPROVED v DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED COMMENTS: DEPT: BUILDING FINAL BUILDING INSPECT~ ENGINEERING FIRE PLANNING ~T LITE PLAN CHECK#: CB973674 PERMIT#: CB973674 PROJECT NAME : PLAN 7,PHS 1,2570+577 GAR COBBLESTONE,GREYSTONE HOMES ADDRESS: 0 \~ "2...\-\. "::)~~\:,.._, ~r CONTACT PERSON/PHONE#: C/TREY/603-0056 SEWER DIST: WATER DIST: Lot# 7 DATE: 06/02/98 PERMIT TYPE: SFD ~~j' if fil ~ t' V ,; , .. - '.: r~ I . JM. -2 1998 ___ __.I :... ... CARLSBAD i , .. "''rt"~' WATER DISTRICT _, ============================================= INSPEC~~ BY:~~ INSPECTED BY: INSPECTED BY: COMMENTS: ECTED: ~PPROVED ~ISAPPROVED _ DATE INSPECTED: ___ APPROVED DISAPPROVED DATE INSPECTED: APPROVED DISAPPROVED ' FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING CMWD ~ PLAN CHECK#: CB973674 PERMIT#: CB973674 PROJECT NAME: PLAN 7,PHS 1,2570+577 GAR COBBLESTONE,GREYSTONE HOMES ADDRESS: 0 \~ ~'-\ ~~f>h: .. _. "bt"" CONTACT PERSON/PHONE#: C/TREY/603-0056 SEWER DIST: WATER DIST: - Lot# 7 ~~~PECTE~C__ DATE 1 ~ INSPECTED: \() -s:_i APPROVED INSPECTED BY: INSPECTED BY: COMMENTS: .. DATE INSPECTED: ___ APPROVED DATE INSPECTED: ___ APPROVED DATE: 06/02/98 PERMIT TYPE: SFD DISAPPROVED X DISAPPROVED DISAPPROVED JOB NAME LOTN\JMBER ADDRESS PERMIT NUMBER Mar Brisa 7 Plan 7 1424 Sapphire Drive 973674 ELONGATION CABLE DESIGN PULL #I PULL#2 TOTAL I 2-3/8 2-1/2 2 2-3/8 2-l/4 3 2-3/8 2-5/8 4 2-3/8 --- 5 2-3/4 2-3/4 6 2-3/4 2-3/4 7 2-3/4 2-3/4 8 2-3/4 3 9 2-3/4 2-3/4 10 2-3/4 3 l l 2-3/4 3 12 2-3/4 3 13 l-5/8 l-3/4 14 4-1/4 4-l/2 15 4-1/4 4-1/4 16 4-1/4 4-l/2 17 4-3/8 4-7/8 18 4-3/8 4-3/4 19 4-1/8 4-1/4 20 4-l/8 4-l/2 21 2-7/8 3-l/4 22 23 24 25 26 27 28 29 30 INSPECTOR Kerry Embrey #534 NOTES (I) JOB NUMBER GAUGE NUMBER CALIBRATION GAUGE PRESSURE ELONGATION CABLE DESIGN PULL #I 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 ( 1) Rock Pocket 9712339 35 I 1/12/97 5500 PULL#2 TOTAL NOTES SOUTHERN CALIFORNIA SOIL & TESTING, INC. 6280 Riverdale Street, P.O. Box 600627, San Diego, CA 92160, (619) 280-4321 FIELD INSPECTION REPORT PROJECT TITLt:: PROJECT LOCATION: ARCHITECT: GEN. CONTRACTOR: 2/25/98 J. Blakely ICBO #79299 DISTRIBUTION: SCS& T FILE NO: PERMIT NO: 9712339 973674 ENGINEER: Seneca LR.NO: PLAN FILE NO: Marbrisa -Lot 7 1424 Sapphire Dr. William Hezmalhalch Greystone Homes suacONTRACTOR: Specialty Steel POST TENSION CONCRETE Time Arrived: 0630 Time Departed: 0830 Post-Tension Tendons: ASTM A416, 112·. 270 ksi 9 (Pg 1 of 11 Inspected the stressing of Tendon #4; brown, 31' long. Elongation = 2 3/B". This tendon was repaired. The stressing was according to the plans and procedures. To the best of my knowledge, all work was in accordance with the approved plans. 111 Greystone Homes -Brian Nestoroff 111 Greystone Homes -Niels Manley I 1 I City of Carlsbad REVIEWED BY: Michael B. Wheeler, R.C.E. #45358