Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DWG 325-4L; PE 2.91.43; US COMMUNITY SAVINGS BANK; L1-L8
-© Il[Q)-h---------+l-- OWNER: U.S. COMMUNITY SAVINGS BANK 515 ENCINITAS BLVD. ENCINITAS, CALIFORNIA 92024 (619) 943-8282 LOCATION MAP , CITY OF OCEANSIDE HIGHWAY la PACIFIC OCEAN VICINITY MAP NOT TO SCAI.£ CITY OF VISTA ROA CITY OF SAN MARCOS CITY OF ENCINITAS SHEET INDEX TITLE SHEET L-1 IRRIGATION PLAN L-2 PLANTING PLAN L-3 PLANTING ANO IRRIGATION DETAILS L-4 PLANTING AND IRRIGATION DETAILS ANO NOTES L-5 PLANTING AND IRRIGATION SPECIFICATIONS L-6 PLANTING AND IRRIGATION SPECIFICATIONS L-7 PLANTING AND IRRIGATION SPECIFICATIONS L-8 I HEREBY DECLARE THAT I AM THE LICENSED DESIGNER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD IS CONFINED TO REVIEW ONLY AND DOES NOT RELIEVE ME, AS THE LICENSED DESIGNER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. THESE PLANS HAVE BEEN PREPARED IN SUBSTANTIAL, CONFORMANCE WITH THE APPROVED LANDSCAPE CONCEPT PLAN, WATER CONSERVATION PLAN, FIRE PROTECTION PLAN. AND ALL CONDITIONS OF APPROVAL RELATED TO LANDSCAPING. av,""""~ /11/,~~ """' <, W·"/J' ' ;2., ·'---,~ GENERAL NOTES ! L•e ' ) ' ' 1. THE CONTRACTOR MUST NOTIFY THE CITY PLAN CHECK CONSULTANT (619-438- 1161) 72 HOURS (THREE WORKING DAYS), PRIOR TO STARTING CONSTRUCTION. 2. THE LANDSCAPE OR IRrilGATION CONTRACTOR IS TO VERIFY EXISTING P SL AT JOB SITE Pf110R TO INSTALLING LANDSCAPE IRRIGATION SYSTEM. VERIFICATION SHALL ElE MADE WITH THE APPROPRIATE WATER DISTRICT. 3. ALL REDUC[D PRESSURE BACKFLOW PREVENTER$ SHALL ElE TESTED AFTER INSTALLATION, RELOCATION. OR REPAIRS BY A CITY APPROVED CERTIFIED TESTER CALL 438-0218 tOR A LIST OF CITY APPROVED CERTIFIED TESTERS. DFVELOPE;R10WNH-l IS RFSPONSIRI. E FOR SUPPL.YING A COPY OF THE TEST RESULTS TO THE CITY DEPAf1TMENT OF UTILITIES AND MAINTENANCE, 405 OAK STR[[T 4. 5 THE CONTRACTOR IS RESPONSIBLE FOR OflTAINING BUILDING AND Pl UMRlr,G PERMITS PRIOR TO COMMENCING WALL CONSTRUCTION AND IHHIGATION, R[SP[CTIV[LY. 6 lf1RIGATION SYSTEMS FOR 1Nf11VIDUAL PARCF.LS SHALL HAVE POINTS OF CONNl':CTION FOR THE SYSTEM BETWEEN THE WATER METER AND WATER SERVICE RISER INTO [3LJILDING AND AHEAD OF ANY WATER REGULATING DEVICE INSTALLCD roR [JU,LDING --'. -· ' .. . . -._. ' . ,. ae . . ' . ' . '., '•, ,, . /• -__ ·· J.I)·" '" '' ;' ·, ' I ., , (, '/(>. ·t?'. '. !-~ a us design group ~ _I I ' L,c-""~ "'. (c -q,, Linisc,pe 1rt1ilec~ra ■ 1n1imnment,1 ~ming ----2912 hollliiiij"il!!![,ui~ I ~Q_ Nl2E12.vJ G-f'lAA_ "lt--R-{t-0-callsb•l taliforni, !12008 JnPII! m,m-lll7 11 AS BUILT" TITLE DATE REVIE\/ED BY, INSPECTOR DATE ~ I SHBETS I CITY OF CARLSBAD ----~-PLANNING DEPARTMENT 1 .. -,.,~ ' - ... . 4584 ADAMS STREET ' --·-, ·······-·· . _ ... , ........... ,._ PE2.91.~ TITLE SHEET / ,., .•... , .... ,, ... ,_ W""'" APPRO~ ;17., fl ~ . I '--/(_ tJy .... _,.., ( •••-"-•·~-n / ! • ' ASSIS'TANT pj ANNING D!RiECT□ R DATE ' OWN BY: PROJECT NO DRAWING NO. DATE INITIAL : DAIT INITIAL DATT: INlnAL CHKD BY: ENGINEER OF WORK REVISION DESCRIPTION ! OTHER APPROVAL CITY APPROVAL RV\/D BY• HDP 91-21 325-4L SYMBOi. F llM 213 112 . 113 114 EST SST ADJ. MANUFACTUREII • If.NIER IUI ,, f:'-l~l"IF;l7 ... KJN1ER • AGRIRM NQTD ro11 umur •n,1 men· 1. •,._IN CIACI.E INDIC,,,lm N022LE NUh&I\ NOZI\.Ei,IJMllEAII 1,2,S, & 4AM Rl!0Ullll!D l'OR THIS l'AOJECT. SYIIIIO' OQ liil!!I ~ , ... , , ,-..,. ~ .... _. __ ,----.. IF I I<, e 0 Ltl) ........ [ID ~ -@) MANUFACTURER l>EllCRI ·. KING BAOS. INC. BALL VALVE OASIS 12 STATlON OONTROUEA HARDIE 314• CONTffOL VALVE FEBCO REDUCED F~ESSI RE BACKR.OW ASSBIBLY 1• Am LAT£~ .. LINE TYPE 1120 PY~ PIPE CLASS 200 . Am MAIN LINE uu,40· Am nffJST BLOCK Am PVC 91.EEVE. SCH 40 -150 ~eu INUNE WVE.flll£R 30PSIINUNE ' -REGULATOR HARDI• 112" END LINE F' '..., CLAMP Attf'· RIGID PVC 10 POI.Y-HOSE lRANSITION HARDIE 1/2' POl V-HOSE WILKfNS ·_ PREIISUIIE REOULAlOR 1" \ -11At,1 SENSOR DEVICE ~-'v\\ HO!:>E E'JI e, -._.._-.. .........____ ____ {?.. ,._ .. __ ~:TlON LD.NUMBl!II ~ VALVEIIIZE LOT ADJUSTMENT DATA @---N 65"36'51" W . @---S 51'33'33" E @---S 63"31'49" E @---S 68"18'03" E ©---S 69"28'36" E 74.20' 10.31' 14.09' 17.88' 32.33' r····· ·-. r· I _/ DESCRll"l'ION MODEl:'NO, RAD PSI ... : ~,,; SHRUII PCP.IJP P!l-12-10A-V to-" SHRUB RISER PS00-10A-V 10"; .10 ; : ;•.' . .. i.a -1;0: cl:e'' ----....,. ------·-l~t; SHRUII PCP.IJP If>(¼· FR5-30 z:-;~·· '1,.C., \.1'5 1, Z,l;i SHFIIJBRISER PS00-12-A-V 12' 30 1.9 1.S 1.0 ~ ~--DRIP EMITTER IF 20 ISO-FLO 20 2GPH "iia,iiRICS .. . ;J; (tif"AIL MODEL NO. . ~· · .. WLT--BALL VALVE LINE SIZE E/1.-4 LANDSCAPER 12 INTERIOR INSTALLATION Gll.-4. ..... 7Nll.,7'5 F/1.-4 . e25v:ov,9 ·,. i ' . "·, .. .. , .· .. ! .. . ' .---'-: , 'DIL-4', . MN. SIZE fxfx1' 1 -DIAMETER OF 11-E LAT£RALI ms IJL-4 FR30 IJL-4 FJQ18 • FITTINGS AS REQUIRED EHD 1&!5-010 1:ot:vUHt~ ... JUT£ MAT£ STAKES AS A/L-5 REClUIRED SOOSERIES SET -ssPSI 011.-4 IIAt,I a-ECK SEE Pl.AN FOR LOCA110N -- EXISTING EASEMENTS CD-us COMMUNITY SAVINGS BANK, HOLDER OF A 20' WIDE ROAD & UTL ESMT REC 06/14/90 AS DOC #90-323803, O.R. . 1/~ 0.5 0.5 .10 0.9 1.J -... _ ... i : -,,,_,.,, ~di" i ~t".i DETAIL BIL-4 ·B/L-6 BIL-4 B/L-5 A/L-5 \ \ ' \ I ' ' ' \ . .,,_ \ \ \ \ \ I .,,~,",, . ~. "" \ \ I I 1 ' ' !; ,._,,.......... -·"·"·"·-•~. ""~ .. , ..... , .......... ••r- • ,r:·'' @> ,, )f';:F .. /;' SCALE: 1"=10' '., IS' 1 ~USC4,cE .-.... ,q 1:. Y S.,s "/. ,,,,, " J, n -:J; ,,. J.T~l . . I I ·. i ' ., !;/] ('.) •rr·· ------t'rr---=;-,.,;; POC ~-------:-_,_ BAC I'--F L-b J..-J ~~EY eN 1 !=. IZ-. .v\P···J .\ ·-/! ~'{ :}~\~~.) .-,; ' ' 'i \¾f lo -:oJII'"""'! ·· 't, MA1Nt;:rWF A:J,c.Of.\9 Sd,r(t-\ f'i<'Of'\".1"-,T{ Lif.\ic lf..!0TAU..i'l:7 1: J 1--i ';c;]tJ~ $')"',i.RA L\..l':. l, W rn-\ .A G71..lt.L PROFl='.'l<'.T'\" \ . .,IJJ"-: ' ' ". ' . . ; FOR IRRIGATION NOTES AND DETAILS SEE SHEET NO. L-4 & L-5 '1 B ·, ' REVIEWED BY: INSPECTOR esign gro~ 111■111 llll~cllt■ 11111-... IHI lilt. 1111-. 11111 I cr,ill oiflnl• RIii II• ~w11-m1 BUil T" DATE DATE l----+--+----------+-----+--+---l--~ ~2 Cl TY OF CARLSBAD I SHBEETS I ~ •PLANNl'IG DEPARTMENT ::===.:================~:::::::::; DATE INITIAL DATE INITIAL DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL 4584 ADAMS STREET OWN BY, CHKD BY: ___ , RVWO BY: IRRIGATION PLAN PROJECT NO. lt:>P 91-21 DATE I DRAWING NO. 325-4L 91005GR2 " . -, I, i ii ~ t: °', , " ~ 0 " 0 ~ '" < ~' < m, m, " 0 " a " n u \; z I 0 ' 0 0 D D u D ~ ~ i3 z D s 7 m 0 ► C ~ 0 D z 1-:; ~ \; z T 0 r 0 0 Ll " " 0 0 ~ 0 z ~ 5 z m 0 t °ii 0 " z ,, CJ I z G1 z C ~ ~ 0 ]J ~ s z G) z C ~ [IJ m ]J 0 I z G1 z C $ OJ m J) 1 PLANTING LEGEND S mbol □ @ ©o ··,_ ca ~..,_~\l.1/J//~~ ·,.'-"··-.,. ., ~ ·• ::::: . " ff,,__'-'--~~1\\'''@ 0 0 0 ® 0 0 .. {WM) Botanical/Common Name ~ Pyrus kawaxamt Evergreen Pear Bauhinia purpurea Purple Orchid Tree snrubs: BACOW1S Ill II HIS TWIii PEAl(S" PROS I RAlE cotO'ft: IRJSH Ftatht4--51 r; Ceanorhus grlseus horizontalls No Common Name Cistus purpur~us Orchid Roekrose -~ ---...... ,• ----,-~---...--·•' --...,..----.. TLCoMARIA CAPENSIS Cape_ Ho,-,eysucl<Je ~--------------~, .. ;__,......--------...__ ___ --· Echium fastuosum Pride of Madeira Hemeroca/lis 'Premium Lemr ,1 Yet/ow' .. oaylily Lantana. 'Goki Mound' No Common Name --------~-------~-· C"l"fZOSMA Kif?.KII Ho CoY"<'.1-...-·,or. t,h:1me ., __ ..__ •• ----.. ____ -.. .✓-•""\..__ ___ ~-------·-------,._ Myoporum montanus No Commer "',me Nandina domestx:a Heavenly Bamboo Nepeta caflilrla prostrata Catnip Mint Osmanthus fragrans Sweet Olive Po,1stemon hartwegii 'Gamer Garden Penstemon Phormlum renax 'Rubrum' New Zealand Flax Phormium renax 'Jack Sprar . New Zealand Flax Pittosporum tobira 'variegata' No Common Name Pittosporum tobira 'Wheller's Dwarf No Common Name -...,,_____.---~- Taromastans Yellow Bells ~--.-~- Yucca whlpplei Our l.o!d's Candle Zauschneria ctllifOmica Hummingbird Flower Fa;U&P\-.A CIW J4GFIG Groundcover BACaWIS ~ 11 AFIS '1"W PEAKS' PllOSlRATE CO'I011' - @It, Lampranthus spectabifis 'Lavender' Lavender Trailing Ice Plant Gazania Jeucolaena White· Trailing White Gazania Shredded Wood Mulch Ouanllt 2 280 -_,_____......_ 14 Size 24" Box 24" Box 1 Gal Plan 2'-6" O.C. SGal 3 SGal 26 10 -----._,. .. ·· 21 _c.-·.___·~ 45 5 2 1 6 1 7 21 5 -- 11 1 7 6 6 SGal -,~_ i!IB: 1.i!'AA-Pt ::.a --,;:a-~ 20Q: $£. 1 Gal 1 Gal -~~ ___ J 1 Gal 5 Gal 1 Gal 5 Gal 1 Gal SGal 1 Gal SGal SGaL -, .. ,s !!I I SGal 1 Gal 5 Gal 1 Gal 1 Gal 1 Gal Available@ Designed ti, Ph. . #724;5902 Plant 3' O.C. Avail. @ Altman Speci;'!lty Plants, 744•61 ~1. Avsl. @ Altman Specialy Plants, 744 ·8191. ·,,.,,.,,,Avait @San Mmms Growers, 1 -800-338-2332., Avail. @ Altman Specialty Plants. 744-8191. FROM RAT$ l'lanl Cl/ 16" Cl.C. From Flats From Flats ..,_ '4'00 475 SOFT. o1 ... ~ Plant @ 1 s• O.C. Plant @ 12" O.C. Apply at a depth of :r A .j '0 2.. ZONE 3 (WM) ZONE2. (WM) ZONE 4 • (WM) ZONE ff •' ,. -\...._.,_·,.,. ~--'\ ' ", :, *•·+«-hof"' i ... -: ... ~,-;: .. ,, .. ~:~>\<, /'1h1\\1,_\'._ ZONE2 ZONE 2 FOR PLANTING NOTES AND DETAILS SHEET NO. L-4 & L-5 I -------____ [__ -----------------------------------~---------- ! ----+---~ ---------------- ----- -• ~=__j_ ---- ' i ------- ----- ---- ' ---I--------· --------------- ' ------- - ----------------- ' --+-------1------, .. .. ----. -------····-·------···-------·---··--- i I ----· -.. -.. ------------------------------·-· ------·-------- I i ' -1------.. -;-------·----,. .. ··----···-··---·---·-·-···-· ·--·-·-·· ---·--i _______ _____ _j_ __ i ------------. --------------------------- ' ' I L__ ____ L __________ ---' ·-· ··--·-·· --·-···--· ·------~·---~ I ---· I • ---~ ;. -1.-5-10-:--i~2T--Is---l7i\-~~~ t?,UIL.T ooc u M 1e:,1-rAT 1_01:1 _ --·· -r-------(J./J_~ . -.... .. --·-l------~ oA re I . 1N1r1AL r DATE INITlAL DAE iNITTAL ENGINE,R 0;.-·;;0R~Ki REVISION DESCRIPTION ~- OTHER APP~OVAL CITY APPROVAL Lal!tlll llf.llltdn■ lllitlllllll~ -----iii! lllfijstrt,fill, I ,.1;1jj. tllialili II■ ,-1,,. ~!1711-llll "AS BUI LT" ------ P.E:,------EXP_ -·-·--DATE SEE RFVIEW() BY: __ ,,_ -· INSPECTOR DA.TE ~ CITY OF CARLSBAD I SHBTS I PLANNNG DEPARTMENT 3 ~~----··-'· --· ··-~·----~ .. ---~--__ .. _,.,., ... .,_ .. ___ -- 4584 ADAM s STREET PE 2.9t043'1 / " PLANTING PLAN APP~~~r?. llJo/"' (,,({ 'J~ ... DATE ASSISTANT DIECTOFI ____ ,, ___ ,_ - .;, OWN BY: ~j I --PROJcCT No: ··1 DRAl'ilNG NO. CHKD BY: HOP 91-21 325-4L RVWD BY: _ _ , 8 SEE REMOTE CONTROL DETAIL 0 MAlE ADAPTERS 0 SCH. 40 PVC PIPE 0 WYE-FILTER 0 INUNE REGULATOR 0 UNION (SCH. 80) 03" 0 BRICK SUPPORT AROUND ENTIRE BOX 0 1-1/2" @ JUMBO SIZE VALVE BOX @ 1 CUBIC FOOT OF PEA GRAVEL @ MAINLINE @ FEMAlE ADAPTER · -"lt .. , ... ,, JJ==================:::iti~=-:r.::ai ' a_1~,_-,n_, 'l!: ~cl _ 1 3 = E9 - f-ifl :z UI j I. 0. 0 w 1,1 1/1 E9 z I!)= CONTROL VALVE W / REGULATOR AND FILTER S CALLON TU .?<I" I\OX "i'in'.LS ---------------!-' t: R l ' U\ N 'f: ,\/ C l ' I. i\i\ ( S ) rLAN'l' CltC\~'0 UF THU: l" :\l>l'.\'li 1:!NJS!l Ci~AU!: !"!.,\:\IT ROOT:1/d.,L, 111:U:I ,\I~!: Pi:!'. PL\N"l"INC ~;ur::s ·j~)l§3"---~...------PIU:PARED l\ACKJ-'ILL \llX, :'UllDU.: ii fVv'v-,..-'-J SlTl'LL CACK!'lLL !'ll'!OH TO :·'LANT- :-. 9,.• l~'G TO 1\VOill lWOlH1\LL .Sli'n'Ll:\G. Sl:E !'I.ANTIN(; NOTl:.S FOi~ I\M,:K!-"l ! I. MIX. I i ---SCAHJJ:y SOIL AU)\(; Sllll:S ,\ND l\O'l"l'Ofl OF I' LANT! \G I' IT. NOTE ----------- :l'\;'J(:t: ROO'l'R/\I,(. 1) P!-UJ\11.; T!n:i:.s ;\S J)l ru:c l:L) LW j,Nll,SCi\J\!: /\RC! l T TliCT, :: I :\Ml'Tl'I< TREE PLANTING (5 gal.-24" box) ,.,.,.. -~---------... IX4 l{EDWOOD BRACI: LlNGTI! AS RLqUIIH'll ~---~ t';" WID[ ELASTIC 'lit:BGINC, Tl!: ONTO !ll1ACI: fN AN S-1.00P ·:o l'!(EVENT D,\MAGL 'l'O llWNK -----(2) 2" Ill A. X S' LONG Tl(l:i\Tl'D 1.0IICl::'OLI' .,.-=-~ Pl NE STAKf.$ FOi( S GA I_ •. ·:-llEES (2) 2" IJJA. X \I)' LONG TlffATEll LODCl'POJ.L PINE SIAKcS FOR 15 GAi.. -24" IIOX TRl'iS Sl'T s·:-.A Kt:s OUTS lllE :mo-mi\ II. NCTlS: I) INSTALL TIU'!' T;LS ANIJ STAKLS ONl"Y TO l'RUl'EH r.rvr::. TO IIOLD TIU'E Ul'IW:1r;·, l'li,J- P!:R IIEIGHT (S 6'' /d.WVJ': POINT Wl!ii!U.: Tl!!: TRf":f''. i't'llL SNAP TO i\N UPRIGIIT POS1T70N i.W ITSl'I.F If, TOP IS PUl.1.,1:IJ TO ONE SJ'.:E AS If WI ND LOADED AND T' ,EN !ti"' 1.l',\Sr:D. 2) TIH"ES SUPPL!l'D WJTII TOPS 'l"OO LA!((:f FOR HlUNKS TO SUPPOif"f" S!li\LL lHi PRUNED 1\S D[Rf,CTED BY I.AND. MCII. TO liEDUCI: C'WliN WE lGIIT OR PRUNlU TO A NEW Ll'Afli"'I,. JO NOT REMOVE LATLRALS ALONG TIWNK. TREE STAKING (5 gal. -24" box) 211 )( 34 PRINTED ON NO. 1~ eu.a,,iPA1"" • / ::::: !"1: □ i -- I ' i ' , ' ' C \"- ~ --, - .. L_ ___ .. PEDESTAL MOUNT CG",RJLLER PER LEGEND---~ WALL MOUN'! C.ON":RO LL ER PER LEGEND NOTE: FINAL CO ITT ROLLER CCCATION SHALL BE PER THE Qt,;NER A.\10 I.ANO- $CAP£ AqCHITECT I NS.TALL PER HANUfACTLRER INST RUCTIONS. D J'.-;.t.-,·1~'.,i<..._ ('.,0\-~C'L., I ,....1,b.,, ..::,,c.-,;;-.,,.. ' ~-•'/, i I, , J,' ~:,t,;, ..i.---, , f~:.'.::, 6R~ .:.--✓-,!,. 1-,.;:-· '~ ' .----" ' I • •• \. • 120 VOLT W1'E AN ;.ri,,;-,r.,:: 0 CONOUIT :: '.. ~ ./,.> i;:.:, ,-;----;Ill -'-:~' .,~,.,. 1..,. • ' ' rfi..;.;-:-1J ~JRRIGATION AND COITTROL CONT, OL WIRE CONDUIT n,,,.~:::::-~~.{ __ , .. , WIRE. ' -F(NJSa GflAOE l " IN TURF ARrA, 2" JN GROUND COVER AREA , ~ 'I U Ii 00 - ' ,, ·.,..,:_;' ::1 lit::= ~----w . 0 0 ~ 00 ~ -~ w ~ • y ~ . ' w --Y, 2000 PSI CONCRETE BASE PROVIDE 6" CLEAR AI.L SIDES----------' AUTOMATIC CONTROLLER ~----EXISTJNG SLOPE ~--TAPER l: l MAX. CUT .SLQFf ,\.T PLAl,T PIT ~--2" !-1ULCH LAYER PL\1'T CRO\\N OF TREE l" •\BOVE FJ\!SH GR.-\DE 4" HIGH I1'.-\TER RETE":TJO\ B.->.SL,, FOR!~ Ii/SOIL EXCAVAED ON Ul'III I.L S JOE OF TREE l: l '-!AX SLOPc. SURFACE ==-=-, "'\ ' PLA'CT ?OOTBALc. PRl'P.\RI' PFR l'LA'-:Tl \G \OTES -•, ~ ~--"~ ~ -~;' '·<' ~1:l~-a::_ . .- ;>::. _-~ ·:.~: ·~ -: .\.!,, Tl\· IC! ROCTB.,LL DL'IMETEH PL'.\T FERT!LEER TABLETS PER PLA!\Tl ,G NOTl:S PREPARED BACKFILL MIX, PUDDLE A\D SETTLc BACKFILL PRIOR TO PL.'.\Tl\G TO AVOID ROOTBALL SET- TLING. SEE PLA:-!TING NOTES_ SCARIFY SOIL ALONG SIDES .•.ND BOTTOM OF PL"-XTl~G "IT \OTES I , I , 1: SEE DETAIL J FOR STAKP'IG O? S ~ 15 GALLON TREcS. 2) ."-LL l GALLON TREES SHALL RETA!~ \URSERY STAKE. 3) PRU\'E TREES AS DlRf;CTED BY LANDSCAPE ARCfll HCT. SLOPE PLANTING (TREE & SHRUB) rw ICE 1!00 Ill AL UIAMrTLR SHRUB PLANTING -----~cT cillRUll CHOWN l ., 1\IJUVI., FlNISII c;:(111)I- ~---2" MULC'I LAYEil !'I'll PIANTI NG NUT(S -----cl" lllCII lvATl'R RETENTION HASJN HAKE OUT Al'Tl:I! 911 IIAYS II. 0. :, . ---rrNlSII LJ(/\1)!, P/C f"IP2 PlPt :;81c,.< OK. CDt--JC . "vf'rt) RT,;:, /'\LL _,-,'<:::l.JN O ON C: ~p;",,C7EQ ~ ,t:;,ec,i L . -f I I I I I I : ii 1-' '·" ~NCC'R F,"1.GR. 5C+--: ED LJNION -~·---~-- ' '-'-"---1-{-f-rf' ---- ...-\IN. ~-CU-FT c-s-,._ L.__ GFQ--VEL e<J..-1 P E9 REMOTE CONTROL VAL VE E9 _ _j~--------r . ' .. -c I-o:.--- r. · . _-.....; o/_~· /•~! F'P: -~L·~:~ ' ,,,.,.)'" '"·l.,; A.::~., Q_,E~:,,.i;['). ' L1------~---PVC fHIALI' AOAl'TIR, 2 Hl'I) • D LJ~~----=----',---1ivr; M/\INI.INli j~~------Jji-------·I" MIN. CLl'AII QtJ,;:(1:;~2_:~~f----==---ONI. CUBIC l'OOT 3/•I" Hon BALL VALVE --Bl~ !CK /\IH)IJND VAi.VE IHlX l'l:Hl~ll:TEH HJI~ SUl'l'ORJ NOT!c: 1) CLOSE Nil'PLl:S SIIAI.L -''-K)"l IJI' lJSl.ll. 2) CATI: Dk UALL VALYl:S. Anl: NU"i' TO UI' INSTALLUl Wl't·11lN IIW[CATfON CON- 'l"HOI. VAi.Vi, BOXES. DA TE INITIAL J ., r r 12" FROM CONCRETE CURB OH I IEADElt, 6'' FIWM l'ACL' Of. BLDG. 1-~---------S!lltUll ll[AO PER L[GLND L~--------= SCII 80 PVC N[PPLE (LENGTH AS REQUIRED. COLOR TO Bl' GRAY) FINISII (;!(~Ill' lt-=::11 -(2) MAI\LEX STREET ELLS ~.11=c---- '~',11 =-= SCII 40 PVC SXSXT TEE OR SXT ELL l'VC LATERAL l.l NI.' REVISIONS BY ae a us design group Llmi,cope D1chil!ch11 ■ ,.,;,,m.,111 ~,nning NOTE --!~l li~iDUll!e~. SUI!.---- ~============ cirsb,tulifomio!lOlti l) MOUNT AT 90° TO Fl~ISII GRADE 2) INSTALL RISER l 2" ABOVE GRADE IN ALL INTERIOR AREAS AND 6" ABOVf' GI1Allc TN PARK- ING AREAS Wlll:RE CAil$ ovrn- llANG AND IN llAlSED l'I.ANTl'R BEDS. php"' ~S/121-llll SHRUB HEAD ··tl;J I · r 1 I I I ., .. 2" AT l'DC!' DF PAV l NG on WALL POI' -ti!' lll'All l'l'.ll Ll'CENIJ -----'-," ABOVE FINISII CRAIJE Fl~ISII Cl(i\1)I' ~-f---~-tm,-,---,mm~-.,,,,;,n , • · • ·., ~·. 1t1-i.. -:_ ------ 1 m1 1 :r,:_-::; ~_J[lll\ -r-:i-tti------------c~(11 _,1A1n.L:x sT1a,ET 1•1.1. -L-JR}-------------su1 HO PVC Nrl'rl.E, Ll,NGTII AS 10:QUJ l(ED 12" POP-UP ------(2) MARI.EX STP!'fT ELL -----~-sc11 40 l'VC SXSXT TEI' (JI( SXT LLL =------"'d~~-------pvc LAlLRAL L l NE rm l.l'Gl'NIJ 11 AS BUIL T 11 TITLE_________ DATE REVIEI-/ED BY, 4584 ADAMS STREET ING & IRRIGATION DETAILS DATE INITIAL DATE: INITlAL DWN BY: PROJECT NO. DRAWING NO. REDUCED PRESSURE BACKFLOW PREVENTER ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL ~~':JD BJ~,---HOP 91-21 325-4 L • IRRIGATION NOTES 1 . CONTRACTOR SHALL Ifs.STALL IRRIGATION SYSTEMS THAT ARE COMPLETE AND FUNCTIONING IN EVERY WAY. 2. PU\NS ARE DIAGRAMMATIC AND APPROXIMATE. PRECISE LOCATION OF rlEAOS SHALL BE. FIELD ADJUSTED TO MEET MINOR VARIATIONS IN PLAN. 3 CONTRACTOR SrlALL CHECK AND VERIFY ALL SITE CONDITIONS, UTILITIES, AND SERVICES PRIOR TO TRENCHING 4. CONTRACTOR SHALL CHicCK AND VERIFY STATIC WATER PRESSURE READING OF 95 PSI AT STREET PRIOR TO BEGINNING OF WORK. NOTIFY LANDSCAPE AF,CHITECT OF ANY DISCREPANCY. 5. 6 POiNT 01: cor,NECTION (POC) SHALL BE AT METER. CONTRACTOR SHALL FIELD VERIFY SIZE OF WATER METER BEFORE WORK COMMENCES, MINIMUM S:ZE TO BE 3/!L CONTACT LANDSCAPE ARCHITECT IF METER IS SMALLEI! THAN MINIMUM SIZE SPECIFIED. 7. 8. SET PRESSURE REGULA TOI, AT~- DI RECT BURIAL CONTROL. WIRE SHALL BE 24 VOLT, SINGLE CONDUCTOR SOLID COPPER. PLASTIC INSULATED CABLE RATED FOR DIRECT BURIAL APPLICATIONS, UF. UL APf'ROVED. 14 GAUGE (MINIMUM) PILOT WIRE, 12-GAUGE (MINIMUM) FOR COMMON GROUND RETURN WIRE SIZE OF WIRE FOR RUNS OVER 1 DD' LONG SHALL BE PER MAMJF1\CTURER'S SPECS. 9 CONTHACT OR SHALL ElE RESPONSIBLE FOR SLEEVES AND CHASES UNDER PAVING, rHROUGH WALLS, ETC. UNLESS OTHERWISE NOTED. SLEEVING SHALL BE MARKED AT EACH END OF FLA TWORK OR WALLS BY A PAINT DOT IC CONTRACTOR SHALL NOTE LOCATIONS OF TREES ON PLANTING PLAN ANO SrlALL HOUTE IRRIGATION PIPE AND PLACE HEADS TO PREVENT CONFLICTS WITH TREE PLANTING GROUP VALi/ES IN BOXES, PARALLEL TO EACH OTHER, IN PLANTING AREAS. LOCATE PIPE ALONG EOGE OF PLANTING AREAS WHEREVER POSSIBLE. I 1 1 3. 14. 1 6 17. 1 e. 19. FLI.JSH ALL. F'1PE.S CLEAN Pl,IOf, TO INSTALLING SPRINKLER HEADS. AcL POP-UP HEADS TO BE 2·• FROM CURBS AND WALKS, AND 6" FROM BUILDING . ' , . PROVIDE ANTI DRAIN VALVES OR CORRECT LINE SIZE WHERE FIELD CONDITIONS DEMAND, PER PLANS. AND/OR AS REQUIRED. CONTROL WIRES SHALL BE BUNDLED WITH ELECTRICAL TAPE AT 8'-0" INTERVALS AND BURIED BENEATH MAINLINE WHERE POSSIBLE OR AT THE SAME DEPTH AS MAINUNE ALONG EOGES OF PLANTING AREAS. ALL TRENCHES SHALL BE WETTED ANO RECOMPACTED TO 90% MINIMUM UNDER FLATWORK AND 85% IN PLANTING AREAS. CONTRACTOR'S MAINTENANCE PERIOD SHALL l':IQI BE TERMINATED UNl IL THE FOLLOWING CONDITIONS ARE SATISFIED AND APPROVED BY THE LANDSCAPE ARCHlfECf: A VALVES SHALL BE WIRED TO CONTROLLER IN SAME NUMERICAL SEQUENCE AS INDICATED ON l>LANS. l1. PROVIDE PLASTIC SEALED DIAGRAMMATIC PLAN OH SYSTEM IDENTIFYING STATION NUMBERS AND AREA THEY WATER; MOUNT INSIDE EACH CONTRCU..ER. C. CONTRACTOR SHALL MOUNT IRRIGATION SCHEDULING GUIDELINES (PROVIDE Di IN A PLASTIC SLEEVE IN THE CONTROLLER BOX. 0. "AS8UILT" DRAWINGS SHALL INCLUDE LOCATIONS OF ALL MAINS, VALVES, SOURCE Of' ELECTRICAL POWER FOR CONTROLLER CLOCK, CONTROL WIRE SLEEVES, AND BE:LOW GRADE HEADS HAVING A RADIUS OF 30'-0" PLUS. LOCATE BY DIMENSIONING FROM TWO FIXED POINTS (ON REPRODUCIBLE MATEFllAL). (CONTRACTOR MAY USE A BLUEPRINT OF THE SPRINKLER ?LAN AND EDIT IN PERMANENT RED INK F0Fl THE AS-BUILT DRAWING.) :CHOOSE,) ,0HOV1 Di:: THI: rOLLOW1NG TOOLS AND MATERIALS AS PAHl OF Th IS CONTRACT QUANTITY ___l_ DESCRIPTION tQUIPMENT OPERATION MANUALS ANO GUARANTEES. PLASTIC SEAL.ED DIAGRAM OF SYSTEM Af'lEAS. AS-BUILD DRAWINGS. SETS OF AUTOMATIC CONTRCU..ER KEYS FOR EACH CO'-ITFDLLER. QUICK COUPLER VALVE KEYS AND 1 EACH HOSE SWIVEL AND BIBB ASSEMBLIES WRENCH FOR DISASSEMBLING EACH TYPE OF SPRINKLER HEAD SUPPUED. SCREWDRIVER FOR ADJUSTING EACH TYPE OF Sf>f,INKLER HEAD SUPPUED. MANUAL VALVE KEYS. HOSE 8188 KEYS. IRRIGATION SYSTEM IS SHOWN DIAGRAMMATICALLY. LOCATE ALL PIPE AND EOUIPMENl" WITHIN PU\NTING AREAS. GROUP PARALLEL PIPE IN SINGLE TRENCHES WHEF,E f'0&;1BLE 2 0. ANY SUBSTITUTION MUST BE APPROVED IN WHITING BY LANDSCAPE ARCHITECT. 21 _ ALL iRRi(-;ATION MATERIALS ANO PROCEDURES SHALL CONFORM TO ALL LOCAL, MUNICIPAL. Ar-.□ STATE. LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK AND ARE HEREBY INCORPORATED INTO ANO MADE A PART OF THESE NOTES AND THEIR PFlOVISIONS SHALL BE CARRIED OUT HY THE IRRIGATION CONTRACTOR. 2 2, IHHIGA TION CONTRACTOR SHALL GUARANTEE THE ENTIRE IHRIGATION SYSTEM TO BE FREE OF DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FFK)M FINAL ACCEPTANCE HY THE OWNER. 2'.l. IRRIGATION CONT"RACTOR SHALL MAINTAIN THE SYSTEM FOR A PERIOD OF 30 DAYS AND ShALL SCHEDULE WATERING AS REQUIRED ro MAINTAIN HEAl. THY PLANTS. 24 OHlf' EMITTER QUANTITY TO PLANT GUIDELINES. (BASED UPON PLANTS ULTIMATE MATUHE SIZE) 1' T C/\NOPY SHl,UBS 4' 10' CANOPY SHHU8S ALL TREES 1 EMITTER EACH 2 EMITTERS EACH 4 EMITTERS EACH ,5 _ CONTRACTOR TO Ec,TIMATE AN AVERAGE OF 3 L.F. OF HAHDIE EHD0437 MICRO TUBING PER EMIT1 ER OH EQUAL flGER RloPJ1;oc.i!RllPHIC$ PLANTING NOTES 1 . 2. 3. 4. 5. 6. 7. 8, 9 1 0. 1 I . 1 2 LANDSCAPE CONTRACTOR SHALL RECEIVE THE SITE WITHIN PLUS OR MINUS .10 FEET OF FINISH GRADE U.0.N. THE PLANTING PLANS ARE DIAGRAMMATIC. MINOR ADJUSTMENTS IN PLANT LOCATIONS ANO TYPE MAY BE MADE AT THE DISCRETION OF THE LANDSCAPE ARCHITECT. ALL PLANT MATERIAL SHALL BE SUBJECT TO THE APPROVAL OF THE LANDSCAPE ARCHITECT, OWNER, OR OWNER'S REPRESENTATIVE. AND REPLACED UPON REQUEST BEFORE PLANTING , .. ,' '" c/ · .' _ ... , THE LANDSCAPE CONTRACTOR WILL COORDINATE HIS WORK WITH THE OTHER TRADES AND MAINTAIN DRAINAGE DURING CONSTRUCTION. PLANT QUANTITIES ANO AREAS SHOWN ON LEGENDS ARE FOR CONTRACTOR'S CONVENIENCE IN ESTIMATING ONLY. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING PLANT MATERIALS TO COVER ALL AREAS AS SHOWN ON PLANS. LANDSCAPE ARCHITECT, OWNER, OR OWNER'S REPRESENTATIVE SHALL APPROVE FINAL PLACEMENT OF ALL TREES, SHRUBS, ANO VINES PRIOR TO PLANTING. TREE AND SHRUB PITS 15 GALLONS OR SMALLER SHALL BE TWO TIMES ROOTBALL DIAMETER WIDE AND EQUAL WITH ROOTBALL DEPTH. TREE AND SHRUB PITS FOR 20" BOX AND LARGER SHALL BE 1-112 TIMES ROOTBALL DIAMETER WIDE AND EQUAL WITH ROOTBALL DEPTH. TREE GUYING SHALL BE DONE AT CONTRACTOR/OWNER DISCRETION (PER DETA,L) CONTRACTOR SHALL BE RESPONSIBLE FOR THE TREE'S STABILITY DURING THE LENGTH OF THE GUARANTEE PERIOD. ALL STAKING AND GUYING MATERIALS SHALL BE REMOVED AT THE END OF THE 1-YEAR TREE GUARANTEE f'ERIOD. NITROUZED ORGANIC 'MENDMENT SHALL BE BUTLER'S MILL ORGANIC LANDSCAPE MIX PLUS. OR APPROVED EQUAL. PLANTING BACKFILL MIX FOR ALL CONTAINER PLANTS EXCEPT FERNS, AZALt=AS, CAMELLIAS, OR AS NOTED IN PLAN. · · ON SITE SOIL NITROLIZED ORGANIC AMENDMENT AGRI FORM 18-18-6 FERTILIZER AGRICULTURAL GYPSUM IRON SUUFATE 6 CU. YDS. 4CU. YDS I LB. 4 LBS. 1 LB. PLANTING BACKFILL MIX FOR ALL FERNS, AZALEAS, CAMELLIAS SHALL CONSIST OF 113 EXISTING SITE SOIL, 1/3 NITROLIZED ORGANIC AMENDMENT AND 1/3 THOROUGHLY WETTED PEATMOSS, MIXED TO A UNIFORM PLANTING MEDIUM, ANO WATERED IN AFTE.rt PLANTlt-.G WITH TERRA-SOL OR APPROVED EQUIVALENT WET! ING AGENT ALL PLANTS I -GALLON SIZE OR LARGER SHALL RECEIVE AGRIFORM 21-GRAM 20 105 FERTILIZER TABLETS AT THE FOLL.OWING RATES: 1-GALLON; ONE 5-GALLON; TWO 15-GALLON; THREE BOXED TREES: ONE PER 1/2" CALIPER PU\CE TABLET 6 8" DEEP AND IN CONTACT WITH ROOTBALL ALL PLAN] S INSl ALLED FROM FLATS SHALL RECEIVE ONE AGRIFORM 5-GRAM 20 70-5 TABLET EACH, MIXED WITH A HANDFUL. OF MULCH AND BACKFILL. 13 _ BOUGAINVILLAEAS SHALL BE PLANTED WITH INTACT ROOT BALLS. NO BROKEN ROOTBALLS WILL BE ACCEPTED 14. ALL PLANTS cXCEPT BOUGAINVILI.AEAS PLANTE:D FROM CONTAINER$ SHALL HAVE THEIR ROOTB/\LLS SCORED WITH A SHAR? TOOL TO A DEPTH OF 1" IN THREE LONGITUDINAL. INCISIONS AT LOCATIONS SPACED AROUND THE ROOT BALL BEFORE PLACING PLANT IN PLANTING HOLE. 15, ALL TYING MATERIALS AND MARKING TAPES SHALL BE REMOVED AT THE TIME OF PLANTING. 16. STAKES SHALL BE REMOVED FROM VINES. THEN TRAINED TO WALL, POST. OR COLUMN PER PLANTING DETAIL 1 7, CONTRACTOR SHALL VERIFY ALL PLANTING AREA SIZES AND THE EXTENT OF THEIR PLANTING. IF ANY DISCREPANCIES OCCUR, PLEASE BRING THESE TO THE. ATTENTION OF THE OWNER AT THE TIME YOuR BID IS SUBMI-TTEO. 18. ALL BOXED TREE PITS ARE TOBE EVALUATED FOR DRAINAGE, TEST PITS SHOULD BE LOCATED THROUGHOUT THE SITE TO SUPPLY A GOOD CROSS SECTION OF THE ENTIRE PROJECT. THE TEST CONSISTS OF DIGGING TEST PITS 1 FOOT WIDE BY 18" DEEP AND FILLING THE PITS TWICE OVER A 48 HOUR PERIOD IF THE WA1ER LEVEL HA$ NOT MOVED DOWN AT LEAST 1/4" PER HOUR OR MORE, THE SITE SHOUW BE CONSIDERED TO HAVE POOR DRAINAGE CHAl¼CTERISTICS. THE CONTRACTOR IS TO CONTACT THE LANDSCAPE ARCHITECT AND A DRAINAGE PFK>GRAM WILL BE DEVISED FOR THE SITE'S SPECIFIC CONDITIONS. 19 _ THE FOcLOWING SH/ILL BE APPLIED FOR 1,000 SQ. FT. OF PLANTING AREA AND TILLED INTO THE SOIL TO A DEPTH OF 6" FOR ALL LANDSCAPED AREAS WITH A SLOPE OF 3:1 OR LESS. THE CONTRACTOR SHALL USE THE FOLLOWING AMENDMENT SCHEDULE FOR BIDDING PUReOs.E.S ONLY,/ _____ P'.,~ ,.:'.('. ,.· .. / • -, ,. f,,.,,,;.L~ .. -1:'t:?\;-(~.·'·,, ,;•~:·/t:·--r-~;.:··.-:-r- ·/. k""b , ., ,,... j, l --f"} · .... , :.,,-~ ·: i'i.-"'"I 1,-:;,.C:··7' ~ ,.._ :,.-_: . ..,-;-: : ....r::.-...-,, ;_) ,,_ -_, ,' -, --r, / ' I -; ,;'..-,-,/ -::'...(-7~ I ~111"-P" , ·. ;' , , , j • r-·· ···, t··-c.-<._. ,_., >--• ~· ( .. ·· L,t>-,f--, f~ ~ •'[~V ); 1' .... ..rrJ--, -~ ~·-;r,,>(f)<['v/:.~ ,,.._ 100 LBS OF GYPSUM PER 1,000 SQ. FT. 25 LBS. OF AGRIFORM 18 18-6 FERTILIZER PER 1,000 SO. FT. 10 LBS OF IRON SULFA TE f'f.R 1,000 SO FT 5 CUBIC YARDS OF NITROLIZED Of1GANIC AMENDMENT PER 1,000 SO. FT. 2 0, NO IRON SULFATE SHALL COME IN CONTACT WITH AfJY MASONRY SURFACE. 21. SLOPE ALL PLANTING AREAS AWAY FROM BUILDING AT 2% MINIMUM FOR 5 ff.ET MINIMUM, WHERE APPLICABLE. 22. LAWN ARcAS SHALL HAVE A MAXIMUM SLOPE INCLINE OF 4:1, GROUND COVER TO BE 2 1 U.0.N. 2 3. THE FOLLOWING OUTLINE REPRESENTS REQUIRED SITE OBSERVATION MEETINGS FOR THIS PROJECT THE FOLLOWING INDIVIDUALS ARE TO ATTEND EACH OF THESE MEETINGS. PROJECT LANDSCAPE ARCHITECT, CITY LANDSCAPE INSPECTOR, AND A REPRESENTATIVE OF THE LANDSCAPE CONTRACTING FIRM. A TEST OF PRESSURE PIPE; OBSERVE INSTALLATION OF P.O.C., CONTROLLER, TRENCH DEPTHS, BACKFLOW DEVICE AND VALVES. ( NO WORK SHALL BE BACKFILLED UNTIL APPROPRIATE INSPECTIONS AND TESTING HAVE BEEN COMPLETED ANO APPROVED BY THE CITY.) B. FOUR HOUR TEST OF ALL PRESSURE UNES UNDER HYDROSTATIC PRESSURE OF 150 POUNDS PER SQUARE INCH, AND P,10VE WATERTIGHT. C. IRRIGATION COVERAGE TEST. 0. PLACEMENT OF PLANTS PRIOR TO DIGGING PLANT HOLE.S E. PRE-MAINTENANCE WAUK-THROUGH, INCLUDING COUNT OF ALL PLANTS. IRRIC'oATION HicADS, VALVES, ETC. 24. LANDSCAPE CONTRACTOR SHALL MAINTAIN ALL PLANTINGS FOR A PERIOD OF 30 DAYS, GUARANTEE ALL TREES FOR ONE YEAR, AND SHRUBS FOR NINETY DAYS, GROUND COVERS AND LAWN FOR THIRTY DAYS 2 5. THE MAINTENANCE PERIOD SHALL INCLUDE THE FOLLOWING SCOPE OF WORK: 26, 27 28. 29. 30, 31. 32 33, 34. 35, 36. A. REQUIRED WATERING TO MAINTAIN HEALTHY PLANTS B. WEEDING AND REMOVAL OF AfJYWEEDS FROM GROUND COVER AREAS. C REPLACEMENT OF ANY DEAD OR DYING OR DAMAGED TREES, SHRUBS, AND GlDLNDOOVER. D. FILLING AND REPLANTING OR ANY LOW AREAS WHICH MAY CAUSE STAfJDING WATER. E. ADJUSTING OF SPRINKLER HEAD HEIGHTS ANO WATERING PATTERNS. F. FIWNG AND RECOMPACTION OF ERODED AREAS. G WEEKLY REMOVAL OF ALL TRASH, LITTER. CLIPPINGS, AND ALL FOREIGN DEBRIS. H, MOWING AND TRIMMING OF ALL TURF AREAS. TURF IS NOT TO EXCEED 3" IN HEIGHT BEFORE MOWING OPERATIONS, COLLECT GRASS CLIPPINGS DURING MOWING OPERATIONS AND REWOVE FROM SITE. I. AT THIRTY DAYS AFTER PLANTING, ALL PLANTED AREAS FERTILIZE WITH LBS. OF BEST FERTILIZER CO. 16 -8 OR EQUAL PER 1,000 SQ. FT. PFllOR TO THE END OF THE MAINTENANCE PERIOD, LANDSCAPE CONTRACTOR SHALL CONTACT THE OWNER AND ARRANGE A FINAL WAUK THROUGH. OWNER MUST ACCEPT ALL MAINTAINED AREAS IN WRITING PRIOR TO THE END OF THE MAINTENAfJCE PERIOD. ALL SPECIFIED SHRUB BEDS ARE TO HAVE A 3" LAYER OF WALK-ON BARK APPLIED TO THE GROUND SURFACE, SEE PLANTING PLAN FOR AREAS. BARK AVAILABLE@ BUTLERS MILL, PH. 745-1245. DO NOT MOUND MULCH DIRECTLY AROUND PLANT TRUNK, ;,[,\'JC: t.N AREA OF APPROX:MATELY 3" BARE AROUND BASE OF ALL TREES AND SHRUBS CONTRACTOR SHALL VERIFY LOCATION OF ALL UNDERGROUND UTILITIES AND SERVICES PRIOR TO ANY DIGGING. CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR AU. DAMAGE CAUSED BY FAILURE TO 00 SO. BOXED TREES WILL BE APPROVED BY OWNER. ANY SUBSTITUTION MUST BE APPROVED IN WRITING BY LANDSCAPE ARCHITECT. GROUNDCOVER IS NOT SHOWN UNDER SHRUBS FOR GRAPHIC CLARITY. GROUNDCOVERS ARE TO CONTINUE TO DRIPLJNE (AT TIME OF PLANTING) OF ALL SHRUBS . , , · PRIOR TO PLANTING, THE IRRIGATION SYSTEM SHALL BE FULLY OPERATIONAL. ALL PLANTING AREAS SHALL BE THOROUGHLY WATERED IMMEDIATELY AFTER PLANTING AND APPLICATION OF FERTILIZER. LANDSCAPE CONTRACTOR SHALL REMOVE ALL EXISTING VEGETATION, TRASH, CLIPPINGS, ROCK, AND OTHER DEBRIS FROM THE SITE AND DISPOSE OF IT AT AN APPROVED DISPOSAL Si'iE. ADDITIONALLY, THE CONTRACTOR SHALL RAKE AND FINE GRADE ALL AREAS TO BE PLANTED PRIOR TO THE COMMENCEMENT OF PLANTING OPERATIONS. ALL TREES IN TURF AREAS SHALL RECEIVE 'TREE BOOTS' OR APPROVED EQUAL CONTRACTOR SHALL BE HEW RESPONSIBLE FOR AfJY REPAIRS MADE NECESSARY THROUGH THE ACTION-SOR NEGLIGENCE OF HIS OR HER CREW. SLOPE AREAS 6:1 OR STEEPER ARE TO HAVE A JUTE MESH SOIL COVER INSTALLED. STAKE TO THE SLOPE PER MANUFACTURER'S RECOMMENDATIONS. TYPE OF JUTE MESH TO BE APPROVED BY THE CITY OF CARLSBAD LANDSCAPE CONSULTANT. ' -, BOTANICAi NAME CORETI-IROOYNE FILAGINIFOLIA ERIOOONUM FASCICLA..ATUM ESCHSCHCLZIA CALIFORNICA GNAPTHALIUM CALIFORNICUM HEMIZONIA FASCICULATA LOWS SCOPARIUS PLANTAGO INSULARIS STIPA PULCHRA STIPA LEPIDA COMMON NAME LBS/ACRE SAND ASTER 2 FLAT-TOP BUCKWEAT 1 5 CALIFORNIA POPPY 4 CALIFORNIA CUDWEED 2 FASCICULA TEO T ARWEED 4 DEERWEED 5 PLANTAIN 30 PURPLE STIPA 3 FOOTHILL STIPA 3 TOTAL-68 LBS/ACRE -0 D"TE INITIM. ENQNEER OF WORK EHD0437 114' MICRO-TIJBiNG IP~O104 LOCATION STAKE ' AGRIFIM' IF 20 ISO-FLO EMITTER ' ,cc 0400 COUPLER l':11D 1645-0101/2-POLY-HOSE " FINISH GRADE •rnE AGRIFIM IF 20 1$0-FLO EMllTER SPECIFIED MUST BE USED ON TH IS PROJECT. ALL OTHER PRODUCTS SPECIFIED ARE PRODUCTS OF HAHDI[ IHRIGAllON THE CONTRACTOR MAY REOUES T APPHOVAL FOR EQUALS TO All PHODUCTS EXCEPT FOR SPECIFIED EMITTER. ~ ~ -s1muu HEAD PER HGEND f ----.._,_ADJUST ANGU, OF RISER WITl!IN Tl!JS AREA TO ATTAIN THE MAXIMUM DISTANCE OF Ti-mow _ANO WATER DISTRIBUTION possrnw -------sc11 80 PVC RISER (I,ENGTI-1 AS IH'QUIRED, COLO!t TO BE GRAY) ~-------UNI; PERPENDICULAR TO FACI: or SLOPE ( 2) PUNCH-LDC CLAMPS Olt APPROVED EQUAL 114 REBAR ------------:========-PINI Si I GRADE FI'lTlNG AT LATE!tJ\L LINE PER DE1'Ali., SHRUB HEAD ON SLOPE -~------ f!it:· -- D"TE INITIM. DATE INITIAf_ REVISION DESCRIPTION OTHER APP~OVAI. CITY APPROVAi. ~ 5 c-- "AS RCE EXP. RE~EWED BY: . INSPECTOR aeda us desins group ... O<li~liwl • 1811111111/f "'lllf. !Mi lm!!htd.illi!1 Ufisl~ l'.J~lll li!III 11oie gsmo-m1 BUil T" DATE DATE CITY OF' CARLSBAD I SHBETSJ PLANNING DEPARTMENT 4584 ADAMS STREET PE 2.91.0~RRIGATION AND PLANTING NOTES AP~~: lriIJ~ 6-~--- ASSISTANT PLA~G DIRECTOll / DA lt OWN BY: 1 PROJECT ND. DRA~NG N~ CHKD BY: RVWO BY: HDP 91-21 325-4 L 1 ' IRRIGATION SPECIFICATIONS PART l -GENEIU.l .. 1.01 A. ll . C. 1. (I 2 DESC?.IPTlON WOHl'. DISCUSSED IN '.'lll'.i St:CTION INCLUDES THC: FURNISElNG OF /\LL i.,/\BOR, MATERIALS, ANJ EQUIPMENT FEQUIREO TO COMPLETE WOHK INDICATED ON nm DRAWINGS. THE WORK SHAU, lH; PERFORMED lN ACCOH'.ll,NCE WITH 1'HE BES'!' STANDARDS OF PRACTICE RELATING TO TH£ VARIOUS TRADt'.S AND UNDER THE CONTINUOUS SUPERVISIOH Gf /\ COMPE'l'EN'l' FORl'Cl/\N, C/\P/\BLE Oc' INT'ERFEL'l'lNG THE DRAWil,GS, NOTES, AND THESE SPECIFICATIONS. l,,idCATlON ANl! LANDSCAPE WORK MAY HE DONE; CONCURRE'J'l'LY, HOWE'J1;R, LANDSCAPE WORK MAY NOT START IN ANY SECTION PRIOR TG lNSPECTlON AND APFPUVAL OF THE SPRINKLER WOHK. PPlOR TO EXCAVATION FOR IRRIGA'l'lON FlPC:, LOCATE ALL ELEC- T.~1 CAL CABLES, CON DU ITS, AND ALL U'c'lLI Tl:" LINES SO THAT PRO- P J':R PRECAUTIONS MAY Ile: ThKEN NOT 'l'O DA:-tAGE SUCH l.'!PROVEMENTS. IN THE EVENT OF A CONFLICT BETWEEN SUCH LINES AND PIPE LOCl,- TlONS, PROMPTLY NOTIFY 'J'HJ,; LANDSCAPE ARCHITECT Wi!O SHALL Aiill.ANGE FOR RELOCATIO:-l OF Oi'iE OR 'l'l!E OTHER. FAILURE TO F()LLOW THIS Pf<OCEDURr; PLACES UPON THE CONTRACTor, THE HESPON- cdiJILITY F'Oil (NI' HIS O'dN EXPENSE:) /.'.AKlNG ANY AND AJ,L REPAIRS FOR DAMAGE ilESULTING FROM \;QRK HEHEliNDLR. SPEC l/,L CONDITIONS 'fi!E GENERAL CONDITIONS ARE A PART OF TI-IIS SECTION AND THE CONTRACT fOil. Tt!lS \\Otl.K A.ND APPLY TO 'J'HIS SECTION FULLY AS XF lllil'EATJ':D HERE. 1. 0 3 c;ENERAL REQUIRE.MEN'l'S fUHNlSH A1'U lNSTl'.LL ll(!UGJ\TION SY!,;TEM INCLUDING, ANY lNCI- llCN1'AL WOH:, NOT SHO'.-IN OR SPECIFIED WHICH CAN Rt;ASONABLY BE lNF'ERRF:D AS PAHT O:" Tl!E 1,0RK, AS !\EC ESSARY TO PROVIDE A COMPLET,E p,,_Nl) WOHKi1dLE SYSTt;M. l. 0 4 ·..,;,;)hK lUCLU ULD T!IJi F'OLLOWI NG ITt:MS AFE DETEFMiNED TO !Jt; A PA!(T OF THE lFIU- GA':'ION \✓ORK Wllt:N APPLICABLE TO 1'HE PLANS. A. l'. 0. C. COclNl::C'rION 01' SYSTt:M TO EX I STING WATER MAIN OR METER ,; . l<f'.VIL\\ OF U''.'[l.ITY PlANS SHOWING O'l'ci!;R UNDLRGROUND YACIL1TH:S ,·· '1'.k.ENCIJlNG hND EACKFlLL D. i,LL Il<FICi,TION MA'l't:HIAL AND 2QUIPMENT INDICATED ON DP.A\-/INGS t:. AJTOl'iA'I''. C COtl'l'ROLLLE ilND E:.LC'J'!UCAL CONNECTION A. ~LLC~l<lCAL S~ULl-OLl'I' H. i--U~TEE M . .ET.i..'.:H. i_NSTALLA'l'lON ' ' ' .&... + V ,J A. !1I,L 1,oru: (,IW Hl,l'i,'.Rll>L'., SL/\LL !J£ lN FULL ACCORD1'NC£ WITH THE LA'l'f:ST ,WLES /,ND HEGULATlONS OF THE SAFETY ORDERS OF T'l!E ()l VISION Of .l NJJUSTHIAJ.. ;3AFETY; Tl!E UNlfOl<l< PEUMfJING CODE PUBLl!,Jfr::J ll'! THE WESTEHN PLUMBING OE'FICIA'.,S' ASSOCIATION; AND UTIILR Al'FLICAHLE LAWS ()!( iu;GULATlONS. NOTli/.NG IN TIH:St: lJRA~'IIf\GS UH SPECIFICNl'TONS IS 1'0 BS CONS'l'l{U2D 'l'O PERMPl1 WO~~:{ nu:· CONfO!U'1lNG TO TJIJ::SE CODt:S. SHOULD THE CONSTRUCTION DOCU- m;N'(':;, OH INS'l'liUCTIO" EE AT VARIANCB WITH THE AFOREMEN'l'~OJ-:l::D Hi.lLES AN'.) HEGULATI::JlJ:-;, NOTIFY Jo1"\NDSCAPE ,\RCHITECT, AND AWAIT H:S IJ,:S','flUCTlONS ilt:;FOFr; PROCEEDING WITH TEE 'r/ORK AFfTCTl::tl. l. 07 Vi'.i(MITS AND Fl::ES A. UBTAlN ALL Ft:lU'1l'J'S AND PAY RL()Lll\ED FE!::S 'l'O ANY GOVERNMENTAL /\Gt:t-.CY :IAV INl; JU,U'.iDlCTION OVER THE hORK. ARRAt,GE FOR IN- SPECTIONS il.EQ~IHED BY LOCAL ORDl~ANCES DURING THE COURSB OF COt,STEUC'l'ION AS REQul RED. ON COMPLETION OF THE WORK, ,;A'l'ISFF.,.;'I'ORY EVIOENCE SHill.L BE FURNI:OHf.D TD LANCSCA.PE ARCHI- 1'1::CT Tc) SIJCW 'fi!AT ALL WORK HAS iJEEN INSTALLED IN ACCORDANCE lvl'/'11 '!'lit: OHur:,ilNCt:S i\NLJ COLJr; FS'.)UIRl:.M,,~'fS, A. W!!Ei-lL\/EH. 'l'l-H: 'J'EHMS "APPROVE," "r~PPROVAL," OR "APPROVEU 11 AES USED 11-. TIit: SPEC1FlCATlONS, Tl!Ei' SJIALL Mt:AN THE APPROVAL 01:c LP,tJDSCi~L'E l,H.CHITECT IN WRITING. 1.09 SCIIELJUJ.8 OF WORK A. SCHEllULF; ,\NU COOHDINA'J'E THE ELECT!UCAL A.ND \'iATER CONNECTIONS, AND TH£ Pl.ACLMEN'r Oi:' MATERIAL AND t:QUIPMtNT IN A. MANNEK THAT WILL Efl'EC'I' Tl!£ EilRLTEST CO.'IPLETION OE' 'l'HE liORK IN CONFOR- MANCE Wl TH Tl!L CONSTf(UCTlON PROGRESS SCllEDLILE, l'A'.iT 2 -f)ECIVEl<Y, S':'ORAGi':, AND HANDLlNG 2.01 NUTiFIC/\TJON A. PllOVlUE NO'i.iFJC,S'J'l(HJ OF THE DELIVERY SCHEDULE IN ADVANC£ SO MATJ.;PIAL MAY lE TNSPECTED UPON l.fc!UVAL AT THE JOB SITE. HE:MCVE UNAC'CH"l'AtJLt; MATERIAL FROM THE JOIJ SITE: IHMEDIATJ::LY. 2.U2 PHO'ILC'l'I0N f lGER REJ>ROGRAPHIC.$ A. Pll.OTECT WORK AND MATERV,LS Ut-.Dlrn THIS SECTION FllOM DAMAGE DI/HING CONSTHCCTION ilND STORAGE. PCLYVINYL CHLORIDE (PVC) PIPE AND !·-ITTI:1GS SHALL flt SHIELDED FROM lllllliCT SUNLICH'l'. B, ilSSUHE Al,,L kt:SPONSlllILI TY FUR DAMAGE TO EXISTING CONSTHUC- 'l'Iot,, A.ND RESTORC PROPt;RTY TO lTS OHIGIN/\.L CONDITION SHOULD DAMACS OCCUR AS A RESULT OF Tllt: WORK OF THIS SEC:Tl,JN. C. IIAND:.,E; PLASTIC PIPE AND FJT'l'l:NGS CAJllifULl.,Y ilND STORE UNDc:H CGVER TO AVOID DAMilGE. BEDS ON WHICH M.~Tl::RIALS ARE STORED MUST llE FULL Li::NGTH OF PIPE; TO AVOID DAMACP.. ANY PIPE TllA'I' HAS 3ELN DMt,CEll OR DENTED SHAT,L NOT 3E USED IN T,tE WOl-i.K. PART 3 -MAn:RlALS 3.01 A. 3.02 A. 13 • C. D. CONDI'TlON OF Dl::LIV!::RY ALL HATEHIALS 'i'HHOUGHOUT '!'HE SYS1'EM SHALL BE NEW AND IN PBR- FECT CONDITION. NO DEVIATIONS FRO~\ TllE SPECIFICATIONS SHALL BE ACLOWED. THE DECISION OB' LANDSCAPE ARCHITECT SHALL BE FINAL IN THE OETERMINATION OF THE QUALITY OF MATERIALS AND E0Ull','1ENT. FOR A(..L MATERIALS AN lNVOICE SiiALL BE SUDMITTEO SHOW/.NG QUANTlTIES OF MATERIALS. lJESCHIP'I'ION PlaASTIC PIPING: ALL MAIN LINE PlPE SHALJ, BE AN APFROVED Bil.AND, -coo., .. -.<le:, PVC. ilLL l,ATERAL PIPE TO SPRlt;KLERS SHALL BE CLASS 200, TYPE 1120-1220 POLYVINYL CHLORIDE (PVC) PIPE. A~L PIPE SBALL CON!:'ORM 'TO ASTM 01785 AND AS1'M D2241. PLASTIC FIT'I'INGS: SCHEDULE; 40, POLYVINYi. CHLORIDE (PVC) STANDARD WEIGH1', AS M.ANUFACTUHED BY SLOANE, LASCO, OR AN APPROVED EQUAL, ASTM D2464, ASTM 02466, OR ASTM 02467 AS FlliQUIRED. SO!,V8N1' CEM8N'I': CONSIS'I'ENCY. NO ALLOWED. COMPA'l'IBLE \'11'ii PVC PIP2 AND OF PROPER MIXING 0£' SOLVt;NT WlT!! THINNER WILL BE PIPE PRIHl::R: COMPATIBLE WITH PVC PIPE /\ND OF PROPER CONSIS- TENCY. t:. CON1'ROL W 1 l\ES: 2 4 VOLT SOLID WI RE U. L. APPROVED FOR DIRECT llURil,l., IN Gl(OUND. BLilCK #14 CF DIRECT LEAD A.ND WHITE #12 CF COMMON GROUND, UNLESS NOTED ON PLANS. F. WIRE CONDUIT UNDJ,R PAVt:MENT; ASTM Dl785 2" PVC PIPE, SCH. 40. G. SPRINKI.I,R EEADS: OF 'THE MANUFACTURE SPECIFIED IN LEGEND Qt,; DRJ\WIN(;S. H. RISf;RS: SCH. 80 PVC. I. VALVl,', KE'lS: ,·u1uus11 'l'WO .{.2.) JQ" GA.LVA!tl·:/,E!) KEYS ,'OR ADJUST~ ING. REMO'fE CONTROL YAL\/ES. J. PLAS':·cc vr,LVE BOx,:s; CARSON' AMETEK' OR hPPHOVf'.[) EQUAL. K. CONTROLLER: 0:' THE MANUFACT0RL SPJ::CIFICD IN LEGt:ND ON i.JRAWINGi:i. L. CON':'FOLL,ER HOUSING: AS DETAILED IN THESE Pi..ANS, SHEET L-4 - M. REMOTB CON'"'ROL VALVES: OF TIil: MANLFA•::TURE SP£CJFIED IN LEGEND ON DRAWINGS. N. lJACKFLOW PHEVENTEH ( ["-; .. ; ., . F., t'<;E.<:,,..,c-..£) : OF THE MANUFAC- TURE SPl.ClFIED IN LEGEND 0:-l DRAWltiGS. 0. BRASS PIPt: AND FITTINGS: STA.NDAHD WEIGHT, IPS TH,IBAOED, CLASS I 1 85% RED BH .. A.SS. PART 4 -lNS'l'ALLATION 4.01 LAYOUT A. LAYOUT WOR.K AS ACCURATE;..\: AS POSSIBLE TO Ti-IE DRAWINGS. T'HE OR.i\Wl~GS, THOUGH Cll.R£FULLY DRAWN, illlli GENERAL! Y DIA.GRN\HATIC TO THE EXTt:NT THAT SWING JOINTS, OFFSETS AND ALL Fl T'rINGS AF.E NOT SHOWN. JOB CONDITIONS WILL N01' ALWAYS PERMIT J,OCA- TING PIPING, VALVt:S, AND HEADS WlltRE SHOWN. WHEN THIS SITU- ATION OCCllRS, IT SHALL BE IJHOUGHT TO THE LANDSCAPE ARCHITECT'S ATTENTION IMMt:DIA'rEI,Y AND THE RELOCATION DETERMINED IN A JOINT CONFEH£NC!c. THE CONTRACTOR WILL llE HELD flESPONSilJL£ FOR 'l'HE ii.ELOCA'rI NG OF ANY ITLMS WITHOUT FIRST OBTAlNING LhNl"JSCAPE fll(CHI TECT' S APPROVAL. HE SHilLL Rl::MOVE AND RELOCA'rF. SUCH lTEMS AT HIS OWN EXPENSE IF SO DIREC7ED BY THJ;; LA>JDSCAi'E AHCH,TECT. B. MINOR GiANGES IN LOCATIONS TO TtiE A.I,OVE FROM LOCATIONS SHOWN Sttll.LL Bt: MADE WHEN DIRECTED BY LANDSCAPE ARCHITEC'l' AT NO ADDcTlONAL COS'r 1'0 THE OWNJ::R PROVIDING SUCH CHANGE IS ORm;;~i,;D BEFORE SUCH ITEMS OF WORK, OR WORK DIRECTLY CONNECTEO TO SAME ARE INSTALLED, AND PHOVIDING NO ADDI'l'IONAL MATERIALS ARE llliQUIR.ED. 4. 02 EXCAVATING AND TilliNC!llNG A. PRIOR TO EXCAVATION LOCA'l'E ALL UTILITIES, SEE NOTE AT THE Bl::Git,;NINC OF THIS SE:CTION. PERFORM ALL EXCAVATIONS AS RE- QUIJlliD FOR 'fliE INSTALLATION OF Tl!£ WO!ili INCLUDED UNDER THIS SECTION, INCLUDING SHORING OF EARTli lJANKS TO PREVENT CAVE-INS. RESTORE ALI, SURFACES, EXISTING UNDERGROUND INS1'ALLJ\TIONS, . LTC.' DANAGt:D OR CUT AS A Rl,,sULT OF nn: EXCAVATlOt;S' TO THEIR ORJGIN,\L CONDITION AND IN A MANNF;R APFROVED BY LANDSCAPE ARClllTECT. B. /ILL LU::NC:Ht:S St!ALL BE II MINIMUM OF 12" YROM S IDJ:;WALKS, C. TRENCHES SHALL BE />'-ADE WlDE BNOUGH 'I'O AI,LOW A MINIMUM OF 4" BETWL:EN PARALLEL PIPE LINES. MAI N'I'AIN A MINIMUM OE' l '' VERTICAL cu:ARANCE BETWEEN LINES. TRENCHES FOR PIPE Lit;ES SHALL BE MADE OF SUFFICIENT DEPT!JS TO PROVIDE THE MINIMUM COVBR FROM FINISH GRADE AS FOLLOWS, l. 18" MitiIMUM COVER OVER MAIN Lrm:s TO REMOTE CONTROL Vl,LVES. 2. 12" MINIMUM COVER OVER EA7ERAi.. LINES TO HEADS. 3. 24" Mit;IMUM COVER UNDER l!RIVEWAYS '·PAVED PARKING AREAS. ,. /~r -:--:·: -i:-t ( , D. MAINTAIN ALL WA!ThING SIGNS, SHORING, BARRICADES, FLARES, AND RED SIGNAL LANTERNS AS REQUIRED BY THE SAFETY ORDERS OF '!'!IE DIVISION OF INDUSTRIAL SAFETY AND ANY LOCAL ORDINANCES. E. Si..EEVES: BORE UNDER Wll.LKS ANO DHl VES TO A OEPTH CONFORMING ~·o Tfl£ llOTTOM OF r,DJACEilT TRENCHES. INS1'ALL PIPE SLEEVES (2 PIPE DIAMETER SIZES LARGtR THAN PIP£ CARRYING WATER) TO FILL THE BORE. 4.03 A. B. C. PIPE LINE ASSEMBLY BACKPLOW PREVENTER: INSTALL 12" MINIMUM ABOVE GRADE WITH CONCRETE THRUST BLOCKS. REMO'l'E CONTROL VALVES: I NS TALL WHERE SHOWN. GHOIJP TOGETHER WHERE PRACTICAL. PLACE NO CLOSER THAN 12" AND PARALLEL TO SIDEWALK, AND HOUSE IN VALVE BOXES WITH TOPS SET TO GRADE· SNAKE WIRES BESIDE PIPE IN COMMON TRENCH, AT A MINIMCM OF l" FROM PIPE. PROVIDE A 36" LOOP OF WI RE AT EACH VALVE. BUNDLE WIRE AT 10 FOOT INTERVALS WITH A 12" LOOP OE' ELECTRI- CIAN'S TAPE, ALLOWING FOR EXPANSION. CONTROL WIRE SPLICBS SHALL BE ALLOWED ONLY ON RUNS ~,ORE THAN 500' LONG. CRIMP WIRES TOGETHER WITH STA KON #PT-70 CONNECTOR OR APPROVED EQUAL. SEAL CONNECTION WITH APPROVED SEALING COMPOUND. PROVlPE CONDUIT WHERE WIRES RDN UNDER PAVltiG. PLASTIC PIPE AND fITTINGS: PIPE MAY BE ASSEMBLED ANO WELDED ON THE SURFACE. SNAKE PIPE FROM SlDE TO SIDE Of TH.ENCi! BOT- TOM 1'0 ALLOW FOR EXPANSION AND CONTRACTION. SOLVENT-WELD PLASTIC PIPE AND FITTINGS, USING SOLVENTS AND METHODS AS RECOMMENDED BY MANUFACTURER OF THE PIPE, EXCEPT WHERE SCREWED CONNECTIONS ARE REQUIRED. PIPE AND FITTINGS SHALL BE THOR- OUGHLY CLEANED OF DIRT, DUST, AND MOISTURE BEFOPE APPLYING SOLVENT. INSTALL PIPE A'I' TEMPERATURES OVER 40 DEGREES F. IMPORTANT! CLEAN OFF EXCESS SOLVt:NT. SHALL CURE AT EEAST 15 MINUTES BEFORE AND AT LEAST 24 HOURS BEFORE WATl:R IS ALL WELDED JOltiTS MOVING CR HANDLING, PERMITTED IN THE PIPE. D. PLASTIC 1'0 METAL PIPE CONNECTIONS: MAK£ ALL COKNECTIONS BETWEEN PLASTIC PIPE AND METAL PARTS OR PIPE WITH THREADED FITTINGS USING PLASTIC MALE ADAPTERS. APPLY A NON-HARDt:N- ING PIPE DOPE OR TEFLON TAPE TO MALE THREADS. TAKE UP WITH l,IGHT WRENCH PFESSURE. E. SPRINKLER HEADS: INSTALL 12" FROM SIDBWALK, DRIVEWAYS, OR CURBS. PLACE TOP OF POP-UP HEADS FLUSH WITH FINISH GRADE. ALL RISERS SHALL BE OF SCHEDULE 80 PVC PlPE. F. PLUGGING PIPE: CAP OR PLUG ALL OPENINGS AS SOON AS LINES HAVE BEEN INSTALLED TO PREVENT 'l'HE ENTRANCE OF !'-ATERIALS 'I'HAT COULD OBSTRUCT THE PIP£, AND LEAVE IN PLACE UNTIL REMOVAL IS NECESSARY f'OR COMPLETION OF INSTALLATION. G. FLUSHING IRRIGATION SYSTEM: T!IOROUGltl_.Y Fi..US!! OUT ALL WATEH- LINES, THEN INSTALL HEADS, VALVES, AND OTHER HYDRANTS. TEST lN ACCORDANCE WIT'H 'l'HE FOLLOWING GUIDELINES: 1. REQUEST' 1'HE PRESENCE Oi:' LANDSCAPE ARCHITECT 0 AT LEAST r'ORTY-EIGHT (48) HOURS IN ADVANCE OF TESTING. TEST IS TO BE ACCOMPLISHED AT TllE EXPENSE OF CONTRACTOR, AND IN THl': PRESENCE OP THE LANDSCAPE ARCHITECT ,U' SO DESIR£(), OR WITH SUBMITTAL OF RECORDED RESULTS OF TEST. 2. CLNTER LOAD PIPING WITH SUFFICIENT AMOUNT OF BACKFILL TO PREVENT ARCHING OR SLIPPING UNDER VilESSURE. APPLY CONTINUOUS WATER PRESSURE OF Tl!E NUMDER OF POUNDS PER SQUARE INCH SPECIFIED e,-, .'.,I. (A) PRESSURE LINES TO BE T'ESTED FOR FOUlc<. HOUHS (ll) LATERAL Lit;ES 'l'O BE TESTED FOR TWO HOURS 3. REPAIR C:,EA• S RESUL':'ING FROM TESTS AND RETEST UNTlL SYSTEM MEETS SPECIFIED TESTS. t>·Y ~-;-.'· ,;-· ,Uk.t .. H. UPON COMPLETION OF THEv'i'ESTING, THE CONTRACTOR Slli\LL COMPLETE ASSEMbLY AND APJU.ST SPRINKL.E:R HEADS FOR PROPER DISTRIBUTION. 4.04 AUTOMATIC CONTROLLER A. INSTAI..I, CONTROLLER AS SHOWN ON T!IE PLAN, UNLESS OTHC:RWlSE DIRECTED BY 'l'lil:: LANDSCAPE ARCHITr::CT. CONNECT RBMOTE CONTROL VALVES TO CONTROLLER IN A SEQUENCE CORRESPONDING TO VAl.,VE STATION NUMBERS AS SHOWN ON THE PEAhS. B, CONTROLLER CHART: PREPARE A MAP DIAGRAM SHOWING LOCATION OF ALL VALVES, LATERAL LINES, AND ROCTE OF THE CONTHOL WIRE. IDENTIFY ALL VALVES AS TO SIZE, STATION, NUMBER, AND TYPE OF PLANTING IRRIGATED, I.E., LAWN, SHRUBS, OR GROJND COVER. SUBMIT DIAGRAM TO LANDSCAPE ARCfHTE_C:_! FOR APPHOVAL, PRIOR TO FINAL INSPECTION. • .. ' .,. . f iC .. ~ --,- 4.05 BACKFILL AND COMPAC'l'ING A. AF'I'ER SYS'rEM IS OPERATING, AND REQUIRED TESTS AND INSPECTIOtiS HAVE BEEN MADE, llACKFil.,L EXCAVATIONS AND TJQ;NChES WlTE CLEAN SOIL, FR.CE FROM RUBBISH. B. BACKFILL FOR ALL TRENCHES, REGARDLESS OF :'HE TYPE OF PIPE COVERED, SHALL BE COMPACTED TO ; '..,; DENSITY. PART 5 ~ JOIJ COMPLETION 5.01 "AS-BUILT" IRRIGA'l'J;ON DRAWINGS . '.-A}-.. :: ... ,~>c.:..:i..r✓;=. -,-•,,!, :.r.:'._A.:._--·1 -~::.~: (-_) A . .J. PFEPA?.E .. AN "AS-BUILT" DRAWING ON A ,;::,-:;(:Dll.";1 ,:<._cc 'c;;E,'</, ,.,,c,c'-' SHOW DEVIATIONS FROM THE BID DOCUMENTS MAD,; DURING CONSTRUC- TION AFFECTING THE MAIN LINE PI PE, CON'l'ROLLER LOCATIONS, Vill,VES AND SPRINKLER HEADS. Tl!E DRAWINGS SHALL m; DSLIVl::RED TO I .. ANDSCAPE ARCHITECT BEFORE FINAL ACC!:'.PTANCE OF wow;. 5 • 0 2 A. lJ . GUARANTEE ALL WORK SHALL BE GUARANTr;ED FOR ON£ YEAR 1:'HOM DATE OF ACCliP- TANCE AGAihST ALl, DEFECTS IN MATEFIAL, EQUIP~U,N'.[', AND WORK- MANSHIP, GUARANTEE SHALL ALSO COVER FEPAIR OF DAM/\GE TO ilNY PART OF THE PREMISES, RESULTING FROM LE/\1\S OR 01'11ER DEFECTS 1 N MNJ'ERI i"\L, EQUIPMENT, AhD WDRKMANSHIP TO THl:: SATI St'ACTION OF L(1NDSCAPE ARCHITECT. lllii'AIRS, IF REQUTRJ:;D, SH/\LL lllc DONJ:: ],'HOMPT'LY UPON NO'l'I FlCATION !JY LANDSCAPE ARCHI'rECT AT NO COST TO THE OWNER, END OF SECTICN "AS RCE ___ EXP. REVIEWED BY: INSPECTOR aeilifus oesiun group L111•u1uclila.1■ '""'""'-""""l aR ldi iliii.sil!I waa...,.,lillli 11W E!/Fi!l·llll BUil T" DATE DATE J----,1-----t------------+--+----+----+--------I ~6 CITY OF CARLSBAD I SHSEETS I L_~-=~ PLANNING DEPARTMENT t------+--.-----t-------------------;-----1----t------i-------1 -~,: ==:'.....':=============::...':=== DA TE INlllAL DATE INlllAL DATE INITIAi. ENGINEER Of -~ REVISION DESCRIPTION 01HER APPROVAi. Cfl'/ APPROVAL 4584 ADAMS STREET PE 2.91.04o// r ~R~IGATION SPECIFICATIONS APP~YE(): -,/5! /J (/4./~~•"'~ /_-"h-//_fz.-: ASS1StAoif PI..ANNJi(G DIRECTOR / DA TE OWN BY: CHKD BY: __ _ RVWO BY: PROJECT NO. HOP 91-21 DRAWING NO. 325-4 L I . ' ····----------------------------------------------------------------------------------------------· PLANTING SPECIFICATIONS PA.kT 1-01 A. 1. 02 A. A. ti • C. 2. U 2 C. 2.03 b. A. l -Gt:N.2FJ,.L SCOF2 OF WOHK WOJ~ DlSCUSSEU IN THIS SECTION INCLUDES THE FURNISHING Of ALL Ulll()H, MATE!Ui\LS, hND EQCIPMENT REQUIRED TO COMPLE'l'E 'rlO[UC INDIC,,TED ON THE DRAWINGS, THE WORK SHALL lJE PERFORMED IN A'.:COHOANCE WITH THE BEST STANDAPDS OF PRACTICE RELATING ·ro 1'flE Vt,RJOUS Tlv~DES AND UNDER 'l'!!E CON'I'lNUOUS SUPERVISION OF /\ C01\1Pe11EN"l' FCP.EM.l\N, CAPJ\BLF; Of' lN'.l'ER..PR.ETING THE DFAWINGS 1 N01'SS, AND THESE SPECIFICATIONS. IRRIGATION AND LAt-:ilSCi,i'L \'iORK .'1AY BE cJON,; COKCUR1lliNTLY, i'.:VEl~, LJ-\.NDSL~AP£ WOH..K J.-1AY KOT S'l'AHT IN ANY SECTlON PRIOR INS!'LCTlON ANL APi'ROVAL OF' THE SPP.INKGSR WORK. HOW- TO .i_)h.lUl-<. TO EX,:AVA'l'lON fUh PLANTING OR PLACING OF STAKES I LOCAT~ ALL LLECTHICAL CABLES, CONDUITS, SPRINKLER VALVES, AND ALL U'l'I:,ITY LINES SO TILAT PROPER PRECAUTIONS MAY ,ir; TAl(EN NOT TO lJEu1ACL SLJC.:11 IMI'ROVb:MENTS. IN THE C:VENT Of A CONFI,lCT bt:TWELN SLCI! LT NES AND !'LANT LOCATIONS, PROMPTLY NOTH'Y Lfl!WSCAPE ARClll'ITCT ,mo SHALL ARRANGE FOR Re .. ·:•TlcoH FOR Ocit: OH Tm: O'l'JiC:E. FAILUHE TO FOLGOW 'l'lilS PHOCEDUHJ' PIJ\CES UPON TiiL CONT.R.l\CTOJ~ 'J'HE hLSPONSIBLl'l'Y FOR (l\'f HIS OWN LX!]ENSE) Mt,KlNC ANY ANL h,LL R.Lf·'AIHS FO.i.{ Dl\.M/\GE lZESULTING FHOM WOitE dEEEUNLloH. CU--c'l'IFI CATIOJ,;S or CONFORMANCE OH COMP LIAN CE: : H AD::iITION TO T<t,Y O'I'EEH CEWl'IFICATES SPECIFIED, THE CONTRACTOR SHALL FUhNISI; /, CEW!'IFICA'cE WITH EACH DLLl Vf::RY OF bULK MNl'SRH,L STt'f.:tcG '1118 SOUHCL; QLANTITY; S'YPE Of MATf:Hlt,L; AND THAT TLE MAT:cHIAL CONFOIZMS TO TH£ SPLClF ICA':'ION JlliQUIREl'.ENT. FOR BULK i.JELIVEHED :H,CANIC f"ERTILIZER, S'HE C£RT,FICATL SHALL ALSO S'i'ATE THE VOI.,UME, NET WLIGHT, PEilCF:NT OF NITROCc~N, PERCENT OF PliOSPHOlGC ACID, AND THAT S(.UDC;I; IS PROPERLY PROCESSEC ANl.i IHl.L NOT HURi, OR OTHLR\HSE DAl".AGE PLANTS, OE PLANT ROOTS. FUi< OTHEH r'EilTILIZl::RS AND SOIL CONCI'l'JONERS IN CONTAINERS, A SIM) LAH Ct:k'.l'lFJCNil: l··H HiVOlCL SHALL JJE FUhNISHED STA'l'lNG TOTAL QUi\:T~'I Tl L~! DY hlJ~lGHTS /,ND VOLl..lME FOR EACH MATERIAL. THI:;;)': ,:H<'/'IF.lCl,T:CS SIJ\LL Hf; SUBMITTED TO Tl-IE LANDSC/IPE l\HC!ll TLCT PiUOR TU TIii; STT,RT OF THL MAINTt;l\t,NCE PERIOD IF HEQUI HU) BY O'dr-;t.H. l\FTEi< Tlli:: SOIL liAS llE81' PREP AP.ED AS CALLElJ FUH lN TllL SECTION ON '.;OIC PREPA'U\TlON, THE IRHIGATION SYSTLM Ll\S lL:Ct~ 1'.~S'l'h.LLED AND TESTED, AND CONDITIONS AR£ I h\/UH.,rdU.,8 '~'0 ['LANT, 'l'lll~ LANLJSCA.?E CC,1:-,,J'l'RACTGE SHALL REQUEST Jd"l'HU\/t\.L TO S'l.'Ah'l' l·'Lt.r,n~ING }''HOM THE LANDSCAPE ARCHI'l'EC'l'. l.:.t'.\('i'J:-'ll~U Lid.11.)J:<J',TOHY 'l'ES'l' H.£POH'l'S: SUBMI'1' }'OH !'1.PPH.OVAL, Cf:U.'.i'lFlLD CCPIES OF Till-~ REPORTS Or'' 'I'J-:;S'I'S LlSTl:.:0 BELOW AND .k[(jUlHED 1.N ;---1,,;:_::Ft:F1.::NCEU PL.ULICN::.'IONS FOR THE FOLl~OWING Jv:ATE- l\.lALS: l. A,~1-dCUL'l'Ui.d·.: .SUl'.i.'h.blLITY SOIL 'T!:''.S'l'.S h'lLL DE MP.D.I:: BY 'I'Ht CONTW\l~TOH AFTLR ,<OUGH GHADING JS CGMPLETt:D AND COI,'l'RAC- TOH Sll/;LL l,DJUS':' SOIL AMEND!'.ENTS l,ND COKTAACT SU~\ /ICCOf<D- lhCLY - 2 -L1ELl 'JLHY, S'.l'OH/\GE AND HANDLING ULLIVEHY FHUVlLJ:~ N()'l'lflCA'l'lDN Ur' TliE D.L:::LIVLHY SC.l:it:DULi:: lN l\DVFiNCl~ SU HA.TFHIAL MAY BE INSPEC'l'ED UPCI\ AkH.lV/1.l.. A'r 'fHE JOB Sl'I'E. kt::1-iOVE UNi1l:CEPTAlE,L: M.A'l'LlllAL FHCM '!'HE JOb SITE JM.MJ-:DIATELY. l"i-<UTLCT l:-'L!,NTS UU.-UN(; ~)LLIVERY TO Pl-lli\11:.:N'I' DAMAGE ·ro tHE H~)OT UA~LS OH: .... ~-,_,:,.~·c.1..., te,t~ or:' LE/\.VLS. PHOTEC'I' TRE2S D:JHlNG T?J,NfJ- POl<.',f W,: T-:i'lNC ll-J TllL bi'(1\NCHL:S AND COVEHING ALL t:XPC!:-.iED B h)\NCU.:.,;s . [,L~~lVL:~ P1.:~_;'~'lClD1:~·; /ttJj'j '.""]OIL fUMIGAN'l'S TO THE SI'l'L lN '~'HE onr- CTNr~L \.INCP.L:UEIJ COU.l'l....INLH.S. CONTAINERS 'I'HNl' DO NOT HA.VE r, Lf:CJBJ,c; L!sbLL THXl' IUENTlfltS TH!:: ENVIHONMEI\TA_L Pf(()1'ECTION l\CJ•;NCY lU~Cif/l'!U1.'flU1•; G.l!l'-'ll:LEl1 AND TH.:: MA~UFAC'11UEH' S H.CGlSTEH.ED us;.;:'.:., l'HI.L 1.3,!:: JU-.:J1:;C'J'L[:. l. CJVI\Sll!t: '.i'l'UhACE Sl!i,LL l\E J>FOTC:C,:TCJ f"liOM THE WlND, ~I • -KLL.P PLAN'N.:, lN:·_~LUDTNG '.:.'HUSE lN CONTAIN.EHS, IN A MOIST CUNUI'l'10N UY ~✓ATERJNG WITH FINE l'·HST SPRAY. KtLP c:n,su,'1 AND FLHT:;:LJ.ZEH lh UHY S'l'UH.l\.(~E A.ND /\Wt-.Y FH.OM CC1NTA1,; l CiAN'l'S. IJO NOT t;Tom:: SDlL S'l'EhILANT AND HE!UHC lDFS \\ITH AN¥ OT!lt:I< Lf\NLJSC,'\PL r,,1ATEHii\LS. S'l\J:2.E IN AN A.PPH.OVE:.J, LOCKED, SEP,\H/\'l'l•; STL·U.JCTUM QR \/UllCLE. HANDLING l'Lf,N'!'S, T/\K~ U\HE 'l'O AVGID G.LJ"1ACING PLAN'l'S :;ElNG /1.0VE:D Fl,UH T1E·: NLHSEHY GIi. S'fOIU\C.l~ AHEA TO 'l'HE PL.l',NTING SI'ft;. EANDLE /\LL l'Lt,NTS Ci\!Z!-:1-'LLLY 'h) J\\/UIO Ck.t .. CKIN,'.: ()!'~ BF.EA.KING 'l't-iE R:JUT bALL. DC M)'l' Hl\NULt: l)LANT~:; EY 'I'liE 'l'JUJNK OH S'~'EM. H.EMO',./E Ol1.Jvl.A(~LD fLANT.::; Ci!~'. PL/d-l'l'S WlTH BI~OKEN OE CH.ACJ-<CD HOOT l3ALLS Yr,:o_~ 'l'iil:.: s 1 ·tr:. :;-;1'EC1Mt:~~ i-'LAh'l'S S~!/-..Ll. bE Pl.J\.NTLD, MUL::.:HED 1 CiJYED 1 AND IN A BASIN !-.ND ~--1,;F.TlLlZLD VilTlilN 48 HOURS AFTER FEMOVAL .:_.-kOM PBL- VIOUS LOCtl':'lON. JUtJ (J,NUlTlON:i JlLhN1'ING CONDITIONS; GHOUtcu IS MUD:.>Y OR IK iNC. PLANTING SHALL NUT HE UONic l,l!C:N Tl!E r,N UNSNl'lSFACTOF-Y CONDITION FOi'-!'GANT~ : 2 _ O 5 A, WORK SHALL Bi:: SCBJECT TO THE TERMS OF THE CLAUSi:: ENTl'l'l.fiJ "WJ\Hl1/i.N'l'Y Of CONSTRUCTION" OF 'I'HE GENER.i\L PHOVXSlONS, EXCEP'l~ THAT l?l,ANT MATERIAL SHALL BE GUARANTEED THROUGH Tl-IE PLANT MAINTENANCE PERIOD (SEE 5.03). ALL PLANTINGS SHALL BE GUARANTEED /--·:::, SF'EcCIF:ED Jt,1 T t":E PLA'-':INC,-NO:=a-=.. ANY MATEHIAG TllA'l' IS NO'!' GROWlNG PROPERLY DURING THIS l'ERIOD St!ALL BE FEPLACEll !JY THE LANO- SCAPE CONTRACTOR WITlilN SEVEN (7) DAYS AFTER '.:'HE RECEIPT OF A WHI 'I'TEN NOTICE llY THE LANDSCAPE ARC!HTECT. ALL PLANT MA'I'ERI ALS SEALL BE GUARANTEED FOR TllE ORIGINAL PERIOD, S1"/\R'l'- ING FROM TliE DATE OF REPLACEMENT. THE CON'l'l-\AC'l'OR'S GUARAN'l'EE HAY BE EXTENLJED BY THE LANIJSCAPE ARCHITECT IN CASES WHERE PLAKTS Al:Ul SLOW TO EScABLISH. IF THfc CON'1'FACTOR fAlLS TO ~lAl<E P.EPLACEMBNTS WI'fflII\ 'l't!E 'l"IME LIMIT, THE OWKER MAY HEPLACE TH£M AT THE CONTRACTOR'S EXPENSB AF1'ER DlJLY NO'l'IFYlNG HIM. PAFT 3 -PRODUCTS ].01 A. 13 • C. l) . I.:. f. 3.CJ 1, . B. PLANTS PLAN'I' MATERIAL SHA;,G BE FURNlSJED IN j'JlE QUANTITIC:S AND/0!\ SPACING AS SHOWN, OR NOTED FOP. t:ACH LOCATION, AND SHALL BE OF THE SPECIES, KINIJS, SIZt:S, ETC., AS SYMBOLIZED lsND/OP. Dt:SCRllJED IN 1'HE "GIST Of l'Lhl,T MATERIALS" AS lNDICATLD ON THE DP.AWINGS. PLAN1' NAHF;s INDICATED OR LIS'rED Iii THE ''LIS'r Of PLANT MATERIALS" ON THE DRAWINGS CONFOJZM TO "S'l'ANDAHD PLANT NAMES" ESTABLISHED BY •;1E: AME HI CAN JOINT COMMITTEE ON HOP.TlCCLTURAL NOMENCLATURE, EXCEPT FOR NA!·'.ES NCYi' COVER.ED Hl;REIN, TliE ESTil.!JLISHED CUSTOM O!-' THE NURSLP.Y 15 l-'OLLOWED. PLANTING STOCK: PLANTING STOCK SHALL DL W::LL-BRJ\NCHED AND v/ELL-FORMED, SOUND, VIGOHOUS, HEAL'rHY, AND FRE,; FROM IJISEASE, SUNSCALE, WINDBURN, AB,V,SION, ANIJ HAR.MFUL INSi;;C'!'S OR JNSI:CT EGGS, AND SHALL HAvt; HEl,LTHY, NORMAL, AND UNBROKEN ROOT SYS- TEMS AND NO'r ROOT BOUND. DECEJUOUS THEES AND SHRUBS SUALL DE SY!1J-\E'I'RICAL1.Y Df;VEl,OPEO, OF UNH'OTZM l!AB:!T OF GROWTH, ';/ITH ST;-uu(;J!T BOLES OR S'I'El'_S AND PREF; F'HOM OBJECTIONABLE DlSFJG- URLc!ENTS. EVERGREEN 1'REI:S AND SHRUBS SHALL HAVE l,ELL DEVEL- OPED SYMMLTRICAL TOPS WIT11 TYPICAL SPP.EAD OP BRANCHJ::S FOR EACH PARTICULAR SPECIES OH VARIETY. GROUHD COVERS AND VINES SHt,Ll, llE VIGUEOUS, HAVE THC: NUMBER AND LENG'l'H OF RUNNERS, AND CLUMP srzr; SJ.'ECIFif:D, ANO JJE '.l'IU: PROPER AGE FUR 'l'llE GRADE OF PLANTS SPECIFIED. ONLY VIKES AND CHOvND COVfR PLANTS WELL EGTALILlShEl) IN H.E."-lOVAULE COl\'rAINERS, INTEGRAL CONTAINERS, OR fOIZMfil HOMOGE:JEOCS SOIL Sf:C'l'IONS SHALL DE USLD. PLANTS SHALL NOT BE PRUNED l'RlOP. TO DEJ,JVERY, EXCL?T AS AU'l'HOrn ZED BY TIIC: LA1'USCAPE ARCHITECT' CR HIS REPRESEKTA- TlV.E. lN hO CASE .SHl1.LL TREES 13.E 'l'Ol.JPt;D IH:FQHE DELIVEHY. Sl~LS OF PLANTS: 5Hl'I.LL LIE AS S1'A'I'ED IN '1'H.E PLAN1l' LIS1l1. CONTf.INfrt S'I'OCK il GALLON, S GALLON, At,;D 15 GALLON) SHT,LL liAVE l\C:,;N CHOWN Iii CONT,\INEHS FUR A PEHlOIJ OF TIME SUc'FICl),NT TO DEVELOP ROOT GRUWT!i SUrTICIJ;N'l' 'l'O HOLD THE SOIL /l/ll.,L TO- Gf;TIIEH ·ru TilE SIDE AND Lo-~·1·0.'I OF THE co:n-AINLR IN WHICH IT WAS DELIVERl:D. THL llt:IGl!T AN[) SPREAD OF ALL l'LAN'l' MA'l'ERIAL ,;HALL B,-: ME'sSURED WITH BRANCIIES IN THEIH NORMAL POSITION; AND SHALL lJ8 AS IKDICATic;D ON 'I'liE DllAWlNGS. THE CI',LIPER Of ALL 'l'HEES SHALL BE M.EASUEED 2' -0" ABOV}; THE SURFACC: Of Tm; GROUND. 1,HFR£ CAI,IPEH OR OTHEH ulMENSIONS Or' ANY PLANT MATERIALS ARE OMITTED i,'ll0!1 THE "LIST OF Pl.ANT MATEElALS," lT StlilLL BE AVr:H/\Gl:: STOCK 1:"0P. TYPE LIS'fElJ. PL\NT M.ATEf<IAL: PLANT MATEPIAI. Silt.LL BE NUHSlmY GJ<OWN, UN- LESS O'l'HERW:iSE IN:HCATED. 1. Gi<-OUNO COVER PLAJ\TS SHALL faE WCLL 1<00'.l'ED CU'l'TI!~CS G!'<OhN IN FLATS l1Nf) Sll,\1.,L Rf.MAIN IN THOSI:: F:.rl';'s UN'l'IL PLANTED. SCUS'l'l 'l'U'J.'IOI,.;s: ::.·'DR TEE INlJlCA':'ED PLAN';:' Hl\'l'f.Hli\LS \,'ILL BJ~ Plil/MITTED, Pi!OVIDF:IJ 'l',iE SLJBS'l"lTUTE )1A'l'EFI!ILS ARE APPROVED IN AC\11'!,CE: BY Tll'c LhN,JSCAPL ARCHITCCT, AND T:IL SUBSTITUTIONS AEE t'.ADE AT NO EUDI'T !ON/I!. CHAFGE TO THE 0';/NEH. F;XCEP'l' FOh TJ!l: VAH.ll\TJONS SO AU'I'l!ORIZELl; ALL SUBS'l'I'1'U'TE! PLANT Ml\'l'EHf /\1.S SHALL CONFOhM TO 'J'l-IE ECQUlRE.MENTS U.f THI:,SE .SPI-:ClFICT1.TlONS. lF ACCEP'1'ED SUBSTI'l'UTE .Ml\TI::klALS ARE OF LESS VI,LUl..: 'l'li/1.N THOSE Ji<DJCA':.'J:.D OR SPEC.:IYIED, THE CONTRAC'l' PRICE WILL I.\C: ADJUSTED IN ACCOlt:lANCE 111TH Tilt: P!WVIS 101'3 OF '1'111:: CUN'I'EAC'l'. Al'l'HOVAL: f,l_.l. ;>LAJ,T MATC:HlALS SHALL BE SUBJECT 'l'O THE IN- SPEC'I'ICN AhD AP:?HOV/\L OF 'l'Il.C:: LANDSC/\PE J\HCIII'l'l!.CT, OP HJS P.LPJL:S£NTATIVE, BEFOIU: PLAKTlNC. CONTF.J\C:TOR SIIALL NOTH'Y GANDSCJ\Plc J\ECHITECT :)f ET,CH PJ.J,N'J' M.ATEHIAL DELIV!':RY. ALL PLANTS SUPPLIED TO 1'11£ PRC<IECT (Wl!ETllEil PLANTt:D U'< NOT) Allli SUBJECT TO l{EJEC':.'lON lW THE LANJSCAl'L ARCH) ~'8CT -PLANTS NUT APPH.OVED Sl-'.ALL BC Hi:::MOVED !''H.OM SI'J'J 1.f'J'.MEClA'l'LLY 1\ND REFI..ACED \'-il'l'H SUI'I'!,BLE PLANTS. THE LANDSCl~PE /d?CillTEC'l MAY REJc:CT LN'l'JJU:: LOT OF PLANTS HJcl'lZ!-;1,ElJ'fE:) BY Dt:Fl::C'l'IVE S/1.MPLt:s. SEED~ SOD SEED FOE LAWNS: !\F'l'Lrl. TBS IlUUGA'l'ION HAS BEi.:;N 'l'ESTED 1-'QR COVEF.AGE, SOlL lJH.EFPEJ, ~"\ND FINlSH (~R.A.DED, Tl·lE L!,Wr~ Alh::AS r-,'~\Y B~ SEEDr~n, AS CALLED FOR ON THE PLANS. ALL ~;f'.fDS SHALL BE Bl{OUCHT TO T!IE sr'I'E APPEOPP.IA'l'ELY LABELED AS '!'() ciPECIES AND QUANTI':'IES. ALL SEEIJ SHALL IF APPLIED A'!' THE HATE CALI.,J':D FOE U)I 'l'll.E PLANS. SEED SHALL UE APPLILD AT AN EVEN RA'I'E BY A ~1lcCl!ANlCAL SPRisADER AS APPROVED BY Tl!£ G/INDSCAPE ARCliJTECT. SLLD }'DR HYDROSEEDIM;: ALL SEED le; TO BE DU,l VEJllilJ 'l'O 'l'l!F: ,JOH s:rr:1E, UNMIXED, IN SEPARATE SE.ALLU CONTAINERS. EACH ~;;-:fl.LED c;Ot-JTAINEH Wl~ .. L DE:AtZ TllE SEl;;[) SlJPPLIEHS' TAGS WHICH SEl\LL INDICATL TilE CONTAJNER WElGl!'l', SEGL) TYPE, /\ND Sl~SD PUHlTY, AN!) SEl·~l) G.Li~J-HNA'l'ION T ALL SEED Slii\LL BE Lfilll:.:l .. ED AC.:COHLJlNc; TO STATE A:m Yl::DEF.AL SEHJ L/111S. A SAMPLF; Of EAC.:d SEED TYFE WILL BI.: Dii.J,WN JJI.:FOf(E ~Et:lllNG TO ASSIJl,lc T!IAT S!::FD SP£Cll'!CA'l')011S HAVE Rf:EN ME'!'. PLANT NAM.ES INDICATED OR LTS'l'Eu IN 'l'IIC "LIST OF l'Li'.N'f MATERITsLS" ON THE DP.AWINGS MUST CONFOHM TO "t_-;T/\NDAn~ 1-'LJH~'~' NAMES" ESTABLISHED BY 'l'llE N-1EHlCAN ,JOINT COM!-'.! 'l"l't:1-: ON HOE.I TCULTUi1.AL NOMLNCLATUFJ::. WHEK NAMES ARE NOT COVERED :~Hrru:rN, THJ,: t;STEl.lJLISl!!cD CUSTOM OF THE NUJ{SER¥ IS F\JLLO'vffl), 1. PLACiT ;,JST, AS INDlCATElJ ON lJf{J',,/INGS. C. 3.03 A • 3. 0 5 A. B. C. D. E. 3.06 A. B. C. 3.07 2. SAMPLES, 'tESTS, AND INSPECTIONS: SOURCE OP MA'l'ERIAL SHALL BE FURNISHED IF REQUESTED BY TllE OWNER OR LANDSCAPE ARCHI- TECT. 3. MULCH FOR HYDROSEEIJING: EACH PACKAGE OF CELLULOSE SHAGL SHOW AIR-DRY WEIGHT. FIBER WEIGHT SHALL BE EQU!VAL8NT TO TEN PERCENT MOISTURE AS BASED ON 1'HE TECHNICAL ASSOCI- ATION OF PIJLP AND PAP.Eh INDUSTRY S'l'ANDARDS FOR AIR-DRY CELLULOSE. 4. SLURRY FOR HYDROSEEDING: :JO GROWTH INHIBITING MATERIAG SHALL BE PERMITTEIJ IN THE HYDFOSEED SLURRY. SOD FOR LAWNS: SOD SHALL BE AS INDICATED ON Tt!E Pi,ANS. THE SOURCE OF THE SOD SHALL BE SUBJECT TO APPROVAL OF THE LANlJSCAPE ARCHITECT. THE LANOSCAP8 CONTRACTOR SHALL TAKE PRECAUTIONS IN THE HANDLING AND TEMPORARY S'l'OHAGE OF THE SOD. TOPSOIL WHERE NEW TO?SOIL IS CALLED FOR, PROVIDE NEW TOPSOIL AND/OR l-\OUif"Y EXISTING TOPSOIL TO SUPPLY THE FOLLOWING COMPOSITIONS RE QUI nEMEN'l'S, PH BETWEEN G A1'D 7. 6, CONTAINING FROM 5 TO 20 PERCENT ORGANIC MATT£R AS DETERMINED BY THE ORGANIC CARBON 6A, CHEMICAL ANALYSIS METHOD DESCRIBED IN USDA SOIL SURVEY INVESTIGATION REPORT NO. 1. MAX HlUM PARTICLE SI Zf:, 3/ 4-I NCH. WI'rH MAXIMUM 3 PERCEN'l' RETAINED ON 1/4-INCH SCREEN. SOLUBl,E SALTS SHALL NO'!' EXCEED 600 PPM. OTHER COMPONENTS SHALL BE WI THIN THE FOLLOWING PERCENTAGES: PH ADJUSTERS, SILT CLAY SAND 25-50 10-30 20-35 l. GYPSUM: COMMERCIALLY PACKAGED, FREE PLOWING GYPSUM CON- ThINING NOT LESS THAN 95 PERCENT, BY VOLUME, OF CALCIUM SULPHATE AS ACTIVE INGP.EDIENT. SOIL CONDITIONEP.S USE INIJIVIDUALLY OR IN COMBINATION AS REQUIRED TO MEET SPECI- FIED REQUIREMENTS FOR TOPSOIL. pr:.'J,.'1'' •· SnH 'GNU OS ~ ~ " M M S PEAT, HYPNLJM MOSS PEAT, P.EED-SEDGL PEAT, ANu PEAT HUMCS, t:XCEPT AS OTHERWISE SPECIFIED HEREIN. PSAT SHALL IJE DERIVED FROM A FRESHWATER SITE, SHREDDED AND GRANU- LATED 'I'D PASS /I ',-INCH MESH SCREE!, AND CONDITIONED IN STORAGE PILES FOR AT LEAST SIX .MONTHS PRICJR 1'0 DSE. MANURE: COMMERCIALLY STERJLIZED AND SACKED STEER MANURE CONT'AINING MAXIMUM 2S PERCENT BY VOLUME OF STHAW, SAWDUST, OTHER BEDDING MAT8RIALS FREE OF STONES, STICKS, SOIL, AND TOXIC MATEiUALS liARMFUL 1'0 PLANTS; WELL COMPOSTED AND SCR8ENED TO PASS THROUGH A 1/4-INCH SIEVE, NlTilOLIZl''.D '•/CJOD DEnl -• ·'" VAT IVES: GP.OUND DAfU\, SAWDUST, OR OTHER WOOD WASTE NA1'l::RIAL FREE OF STONES, STICKS, AND TOXIC SUBSTANCES HAJZMJ'UL TO PLAN1'S, STABILIZED WITH Nl'l'ROGEN AND HAVING THE FOLLDWING PROPER:CIES: ?ARTICLE SIZE: MINIMU.M PERCENT BY NF;IGH:C PASSING: 1'0. 4 MESH SCREEN 95 NO. 8 MESH SCREEN 80 Nl'i'P.OGEN CONTENT, MINIMUM J.'ERCENT BASED ON DRY WEIGHT: FE □WOOD SAWDUST 0.5 FIR SAWDCST 0.7 FIR OH PINE BAl:U< 1. 0 COMPOSTED ORGANIC WASTE: CiH:MICAl.aLY TREATED AND COMPOSTED 0i(GANIC WASTES SUCH AS HICE HULLS, SPENT COFFEE BEANS, SLUDGE, PEAT i\ND WOOD WASTES. FJ;!(TILIZEH ANIJ SOJL CONDITIONER: ORGANIC !-\ATEHIALS (EXCUJD- ING HUMAN WASTES) CONTAINING TIJS FOLLOWING MINI.MUM PERCENTAG8S, BY Wf;JG!-lT, HY PLANT FOOD NUTRIENTS, AND HUMUS. FEHTil,IZER 5% NI'I'HOGEN 3%. PHOSPHATE 1% POTASH soi HUMUS 15% flUMIC /ICIDS FEFTILIZER: COMPLE1'E COMMEHCIAG, GRANUCAR t'ERTILI ZBR CON- TAINING THE FOLLO';/Il,G MINIMUM PERCENTAGCS, BY WEIGHT, OF PLANT FDOD NU'l'RIENTS: 18% AVATLABLE NITROGEN 18% AV /,I LAl<LE PHOSPHOROUS 6% AVAILABLE POTASSIUM l. 8i SULFLH 1.5% IRON F,;inrLIZER PLANTING TABLETS, 1'IGH1'LY COMPRESSED FERTILIZEP CHIPS FORMING A TABLET THAT IS lNSOGUlJGE IN WATER IS DESIGNED 'l'O PP.OVID£ A CONTINUOUS RELEAS8 OF NUTRIENTS FOR AT LEAS1' 24 MONTHS AND CONTAINS THE FOLLOWING MINIMUM PERCENTAGES, BY v/EIGfl'l', 01'" PLANT FOOD NUTRlE:NTS, 20% AVAII,AilLE NITHOGEN 10% AVAILABLE PHOSPHORUS 5t AVAILAB!,E POTASSIUM PLANTlNG TABL!::TS SHAGL WEIGH APPROXIMATELY 21 GRA.'1S EACH FOR TREES AND SHRUBS AND 5 GRAMS EilCH FOR GROUND COVER PLANTS. 1RON CHELATES; CONTAINING 10 PEHCENT IRON AS METAGLIC. MULC!i SHAI,L BE ; " LAYER OF GROUND AND SHREDDED FIF BARK. 3.08 3.09 1'. jJ • C. u. LIGll'rrlElGHT SOlG FOR PLANTERS A SOIL HIX'!'URl:: OF THE FOLLOWING COMPOSl:'l'ION SHALG BE USE;J FOH IMPOR'r SOIL 'l'O FILL JU\ISf;D PLAN~'ERS AND POTS. SOIL SHALL BE PllliMlXED JJY MACillNi': BLENDt:R PP.IOR T'O IJELlVER¥ TO SIT!::: 9 PARTS BY VOI/.JME -L0/\1'-\EX OR EQIJA:. l PART BY VO! ,JME WASHED PLASTER SAND 2 CU. FT. PER CU. YD. OF MIX PERLITE 10 POUNDS PEH CU. YO. Of MIX MICRO-MAX. PLUS OR l:QC!sL (MICRO-NUTRIENT COMPLEX) 10 POCNIJS PER CU. YD. OF MIX 18-6-8 fEKTJLIZEll 1. LOA.'\CX IS A 1,LLNlJ OF OllC!,NTC fP.ACTlON TO Sl?PLY SEVE!v,G DRr:AKDOWN !½TES AND A POR":'ION o,, INORGANIC AMENUMENTS THAT H.Li:iIST FURTHEft BRF .. AY.DOWN. 2. '~'IIE MIX SHALL ALSO CONTAIN A LONG LASTIN:; FOIZM OF IhON iG.U.4~) AND A NUN-IONIC WE1'TINC ACENT, AVAILAHGE FROM BUTLER'S MIL~, INC., LOC!,'l"ED IN SAN DIEGO. TREE STAKING A.ND GUYING MAT;:;hlAL STAKES: SHALL !JE 10' LODGEPOLE STAKES l'OINT8D ON ON£ END. TREE TIES: SHALL l:H:; CI~CH TIE OR APPROVED EQUAL_ ANCHORS: SHALL BE DUCKBILL (TM) PROIJCCT OF APP EDP HI ATE SIZ£ AS RECOMMENDED B¥ MANUFACTURER (FORESIGHT INDUSTRIES, INC., P.C. BOX 4067, CHEYENNE, v/Y 82003). GUYING WIHE: ,;llALL lJJ.; #9 ZINC-COA'l':C:D WIRE. E. HOSE CHAFING GUARDS, SHALL BE 2-PLY REINFU,,Ci:D RUBBER OR PLASTIC HOS8, '," or 3/4" fl, 1'() COVER WlHE AT AU, POINTS OF CONT/ICT WITH THJ;E. Y -TURNBUCYLSS: AS REQCIRED, GALVANIZED 3" M~KL'-1UI-'. LENG'l'HWISi'; DIMENSION. 3 .10 ?ES'l'lCIDES l,ND CflEMICAL CONTF.0),S SHALL BE USED IN THEih AP!'hClP,lI/ITE A,'PLICATlO'\lS WITH STHICT ADHERENCE TO M.ANIJFACTUP.ERS SPC:CIFICATIONS & I'\!STHUCTIONS. A. BROADLEAf WEED cot,TRO:.-SHALL llE WEED B, GONi:, OH OTIIEE 2-4-D I3A.SED PHODUC'l'S. B. PHE-EMERGENCc; Ai'l'LICATIDNS: EPT'AM, TllliYLAN, SURFLAN OR EONSTAR. C. POST-LMEHGENCE APp; .. ICATION: ROUNDUP. D. INSI-:CT CON'i'HOL SHAl,G llE SPi:CTHJ\ClDC:, MALATdION-SO, lllAZINON OR AS DEEM.ED APPIWPEIATE BY THE LANDSCAPE Al!CJIITECT. g. FCNGUS CO:>ITFOG Si!ALL BE DACONIL OR BOP.DOIL. F. AL'l'ERNATIVE PRODUCTS M.li.Y BE USED IF 1\PPHOV,i,.;U IN hlJ<I'~'ING BY THE LANDSCAPE /IRCHI '!'ECT. 3, 11 PLANT I NG SOE, MIXTURE MIXTURE ShALl. lJE THOROUGHLY MIXED TO TiiE Pi<OPOil'l'lUNS GIVEN ON TIIE PLANS. PART 4 -EXECUTION 4.01 P.l-lliPAlU\TION O.r:.' PLAh''I'INC BEUS A, AJ,'TER ALf, '!'!lliNCHES J:N PLAN'l'l NG AREAS HAVE ·BElilN &OAKlilD -AND COHPA.C'l'ED., AND ALL AREAS·-WI1'H SLOPES OF LESS '!'HAN 4, l >1AVE BEEN ROUGH GRADlilD, THESE ...u;;p,.g ... SHALL BE. cross~mPPED & TILLED B. C. I) • 4.02 A. .,i,, AMENDED ,c···f'ER · PLAN&-,---'ID-,A •cl:tEP'l'IL .. OF. 8 ~,_,·:-,~ov,:_ S.•l"ONt:S !. DEBRIS LARGER THJ'ilf". 2I;. TNCl'fES0• IH -DlAMETF: TT. 't\JHt' AREAS: Af,L. AHEAS 'l'O BE .PbAN'l'ED WI'l'H 1"UhJ,' SclALL BE THROUGHLY TII,,EO" -!a -AMENDEDC,-1'.:R. FLAN6, TO MINIMUM DEPTH OF .. ,a._. INCIIE &: B-¥--SGA&.1;1"-=,-· .wsrrl"G; .. , . ..,.RR3WHIG ,,-.:-w.-"-ER A·P PROVED ME TH ODS-. ., . ..--~,~g5,c,:,;/j.W,¥,W:.T!!l''iN''"()NF. I Meir ·J N ANY Dl.l•I.CNSlO!'f 'REl'll\HITNG''Ul'E-5J.J.REAEB:'cAFPER 'PILLAGE .• ··· ADD AND TILL IN PiLL'.SOTL, A.ME·fIDffl'!'Wl'SC;,:::,::M,ccs@h-1',-T,fif,-F0!l !N-··M·AN·S·:·· 'l'0 A DEPTH OF 8 11 _ • SLOPES: 'l'l!E LANDSCAPE CONTRACTOR WILL H£C£IVE Ai.,C SLOPFS AT FINISH GRADE. ALL SCOPES SHALL lJE INSPSCTED BY TIIE l./\NDSCAPE AhCHJ'I'EC-1" PIUOH 'l'O HYDHOSL!::lJlNG TO INSURE THAT THEY ARE FREE OF EHOSION, GULLIES, WEl:;l)S, OR OTHEH OELETEHIOUS 1-'J\TERIALS TO PROVJ[)t: A SE,;!) BED TYPICAL 'I'O GkADLD Sl,C>PES IN THAT RLGION. SLOPl::S SHALL NOT BE DISTURBED IN A HANNER WIIICH Uli\N(;E:s Till, SOIL COMPACTION ESTAllLJSHEIJ HY '!'!IE sore E~GI!:FE:HS. IN PARTl CIJLAR, Sl.OPC:S SHALL NOT BE MADE MORE PEfL'IEABLE TO WATER, THUS CRi:A'l'ING AN LNSTABGE SURFACE AREA. SOIL TREA'rHENT: APPLY AilEAS LISTED BELOW FOR PAAAGRAPH "APPLICA'I'lON THE f'OLLOWI NG SOIL THl-:,\TMENTS TO THE r.:ACH THEAT!-\Eli1'. roll APPLIC.:Nl'ION, SEE or FJ:STICllJC:S" lN TIIIS SPECIFICATION. l. 2. 3. SELe;cTIVIC:-COMl.\lNT,TION 1,EC:D CONTl<OL: 6 WEEt:S iiliSID.JAL (}'J'sXIMUM) • PHE-:-EMERGi':NCE CONrHOL -ALL PLAN'l'EO AREAS, EXCf;PT SEEOl::D AHEAS, 'l'v/ICE, ONCE 14 (JAYS MlNI!-\UH AFT!,;!, GHOUND COVLR IS PGANTED. AND ONCE Nr END CW M.,\lNTF.NANCE PERIOD. POST-EMEHGLNCE CONTHDL 1·,,L 1· 1 -" -',.L .) .,hN'.i.'ED AhGA~J -AT .i'\1.L '.i.'li"ll~S ,\S HEQUif(ED. PEST AND Dis.·1:•.A"E" -CONT HOL -AT ALL Tl .'1ES A;; !{EQL lllliD. FINAL Gi!ADING AF':·E R C ·1111 l 1'LETION OF ALL SOIL CONDI'l'lONII\G TILLING \ND co-L TREATING, CO!H<ECT Tl!REGUJ,,'IRlTlES IN FINISllEO SUFF!sC;,~ T~ ~ ~Ll!-'.INATE DEPRESSIONS. l<EMOVE ALG DEHRIS AND STONES LAi,G!cR rHAN ONE INCH Ht:MAINING ON '!'HE SURFAC,;. PRO'l't:CT FTNISHED AREAS FR0.'-1 DA!1AG8 DUI, TO Vc:HICULAR OH PEDES'!'RI71N TRJ\r'FIC: RCE REVIEWED BY: INSPECTOR wng, •cbt~[lWt • !D...0~1!/1~ !Iii II/Olllj sll!d, SIR I <oobol [fiil11>1 l1Dlli jli!ll ~:l/11Mll1 "AS BU I LT" EXP. DATE -------·-DATE I---+-----+--·-------+-----+-----+----~~ CITY Qf7 CARLSBAD PLANNING DEPARTMENT , ~: -. b-Jd-1:?- -· t----+----+-------------------+---+-----l---l-___J 4584 ADAMS STREET ~ --PE 2.91.09/ PLANTING SPECIFICATIONS t---r--+-------------+---+----l-------1-----1 ;:..=AP:c'::P':=:=R~:=,=:,:=za_ 7_~,:::;:; ?.-"F-:~F ·-4:-~l,F~--~===·-~===t,-=,I/-=, n-=::::cc: .. -J·- Ass•-T PLANN""" DIRECTOR / 6 A 1E DATE INITIAL ~ INITIAL CHKD BY: __ _ -·-o .. -rr "iNITIA:-:L-t---------------------+---+-----+-D•-.·-TE·--'--------L!D~WN!.'.'.!c....B~Y'..!:..:...:===J c· £Nc;,NE£R Of WORK REVlSION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY; PROJECT NO, HDP 91-21 DRAWING tiol 325-4 L j i!Gf.R REPROGRAPHIC5 PLA_~TING SPECIF:ICA TIONS, CONTINUED b. ll • L! • uu:p WA';'EhI N,; AND LEACH I Ne;: A} TrcR SOIL CONDITION I NG l\lH) F.[N;\L Gli.ADING IS COMPLETE, COMPACT ltND LEltCH PLAN'l'ING AlIBAS BY HE:AVY l,ATEEING TO A MINIMUM DEPTH OF 12 INCHES. SEEDlNG & SODDING W~LD CONTROL: PRIOR TO ANY SEEDING, IRHIGATE ALL PLANTING AREAS FOR Al'PROXIMATELY TWO (2) WEEKS TO ENCOURAGE WEED SEED GERMINATION. ALLOW WEEDS TO GROI, UN'l'IL TliEY REACH A MAXIMUM HEIGHT OF T\sO TO THREE (2 TO 3) INCHES AND THEN TllOKOUGliLY [;['f\AY WITH TH,o FOLLOWING CONTACT HEfU\ICH!ES: 1. YUK PEKC:NNJAL WLEDS SUCll A$ MORNINC; GLORY AND BLRMUDA, SPH.11..Y h'I TH II ROUND UP - " 2. F(J]-{ ANNUAL hLC:lJS AN) G!\ASSES, SPfu\Y Wl'.'ll PHY'!'r-,f( 560 OK "',-,JEED BOOME.k, II IN W2T SOILS, SPMY WITH 11 h'EED OIL. II 3. IUcMCJVL [\LL WE"::is PHIi)!( TO SELDlNG. DO NOT ALLCJI, TH£ USAc.;,; Of' ANY PRE-}://,ERGENCE HLIUJICllJES OH ''DOWPCN" FOH 1,EED CON'l'l<OL, IJ!{OALJCAST Lf,WN SLSDlNG; AC!.-SEl.cD NOT DHlLLED J!HO '!'Hr~ SOIL MUST BE MGLCHLD Wl1'H ONE-HALF (.½) CUBIC YARD OF FINELY SCREENLD MULC:il OH TOP UIU:SSING PER 1,000 SQUARE FEET AFTER $EEDI Ne;. THE SEED SliALL IlE KE\"T MOIST AT hLL TIMES THROUGfl t'REQUENT LIGHT v/ATERINGS. 'l'HE SEED SH,\LL NOT BE WATEhED TO Tllll POH,T OF PJDDLING. 1\S THL HOOTS REACH DEEPER INTO THE SOIL, T!lll THU, BETWC!:N WA'I'C:RJNCS SHALL BE EXTEND2D. AREAS SHALL !JE PROT!:CTED FROM 'l;l(}H'FlC UNTIL AFT<:R THE FIRST Ml.l'WINc;. NEW LAWNS SHALL NOT lJl': MOWCD SHOllTER '!'HAN 2\ Il\CHES. GRASS SHALL BE CU~' WITH A StihH.P REEL TYPE MOWER. jf:{ iJizJSEED l uc;: 1 SUPERVISlON: ALL HYDROSEEDlNG IS SUBJECT TO APPKOVAL BY THE U\NDSCAPC ARCHITECT OR HIS llliPRESENTATI VE, AND THEY SHALL, IF Nf,;CESSARY, BE RELOCATED AS DIRECTED AS PART (,!>' Tm; CCNT!i.ACT. THE LANDSCAPE hllCHIT2CT OR HIS REPHE- S£1~TAT~VE SHALL SUPERVISE TiiE HYDROSEEDING. 2. HYLJ"lSEED APPLlCATION: A SLURRY OF FERTILJZEH, srco, J. 4 . AND v;U()D PULP OH. FIB.El\ SHA.LL B.2: AGl '1)\TELJ TO PHOV.l: 1E A U~IFOIW MIX, AN() :;HALL BE HYDll.AlJLICALLY SPRAYLD UN TEE SOIL TO ·:, HOVI DE COMP LC TE, EVEN COV£RAGE. 'J'HE ; ./1TERIAL SIIOULU 1,:, UNIFORMLY IMP!(E;(;NATic:J Wl'l'H SEED AND SHALL ALLOW l'LNE'l'HATlC.JLJ Of H.Al NYAl,L AND PEKC:OLATION OF MulSTUJ<.t: INTO 'l'IIL UNUlcFLY :.?JG SOIL. SLURRY MIX'J'UIU': WHICH IIAS NO'." !JCEN Al'PLILD WI','dlN 8 HOUl(S OF MIXING SHALL DE: KEJEC'l'F:IJ. I'IU::JJLAN'l'lNG r'ER'~'ILIZ~H: SHALL BG AH OhCANIC, PELLE'I'ED OH C!IIP TYPE, UN~FORM IN CCMPOSlTION, FREE-FLOWING, SU1TABI,E FOR .I\PPL:i:CA'l'lDN \✓l'I'li APPFOVED EQUlP~N'l'r AN:) UELIVLHED ';'O TIIL SI Tis lN UNOPENLD, (JIU 0!N/,L CONTAINERS, EACH BEAKING TIIE MAl\'.Jl'AC'2UhER' S '.:/iATEMEN'.:' OF GUM<AKTEED ANALYSIS ANU SHALL COL"l'A=N F2H.TJLI ZEHS AS JZECQ~1MENDED :olc' ACHICUL'l'UH,\L S~I'l'Al!H,.i'l'Y SOIL TESTING 1-{JcS\JLTS. FEE- 'rILIZ1:'.H !-lAY U;"-; Appr,11,:-) I,; .,..H ~,,.~E HYDI1•JSEED. ' t~JAlU\NTL~E: ALL l:iYDPJ~-.:. .. t.'.L ,,, ~.Ht.LL l.:-t::: GUA.k .. h.N'l'El:D BY THE CCJN':'RACT:.JR AS TO (;ROiHJi f•.c.U coi':/,L':'H l'O]-{ A PEKIOD OF TIIIKTY (JO) C,,YS Al'Ti::K YlN,,L tC::CLP'l'AliCE HY Tt!t LANDSCAPE AlKlll- '!'LC'J'. Al"<EAS THA'r FAIL 'l'O Gi,()',i SHALL DE RESEEDED UPON D.lllliCTION 01·· THE LANf'•~CAPE AKClii'l'ECT. TIIE CON'l'RACTO]-{ lS c;uBJl::CT TO THIRTY ("0) DAY HJ\INTENi\NCE OF 1'Hl-: Rr.:$!':EDED A.H..EAS. SODUING: SODDING Sjl7,LL lJE DONE IN ACCOlfi».NCE WITH hPSh GUIDE- Lll\E SPEClFICATIOt>lS FOR SODDING. SOD SHALL BE LAID WITHIN 36 HOURS OP 'l'HE ·.yl'ME I'!' ,IAS cvr AT THE SOD }''\RM, NO SOD SHALL BE LAID 'l)IAT !!AS DRILD OUT OR Bl'EN DAf!A1¥D. LAY SOU WITH hL';'CRNt.TE;/JOINT$ IN A MAKNllR THAT INSUR.ES'(;N EVEN-,--SMOOTH SUEFhCC CN A /1°REPAREll SOD BED THAT =s NEITHER EX'cEc;sIVELY DRY NOH WET/ LONG SIDES Of SOD PIECES SHALL BE AT RH,HT ANGLE:S ';'0 if LOPES OR F00',i OF WATER. ON MOUNDS OR SLOPED AREAS, SCU SHALJ/Bc LAID STARTING~"'' O.'l'TOM. AFT£R lJEING LAID, SOC SHAJ,t Bf> ROL!,ED WITH A . . ,:MPTY ROLI,ER DRUM, AND LIGHTU[ TO?-DRESSED AT THE !'!\MS, IF REQUIRED, TO PRODUCE A SM<;IOT!! FINISH. IMMEDIATELY AFTER ROLLING, SOD SHALL BE W/,T)?]{f~D AT A AATE SUFFICIENT TO INSURE THORCJUGH WETTING Of' ',.'ijE SOIL 'llO A DEPTH OF A'l" LEAS'l' t'OUH INCH!'S. ONCE SOD HAS U00'l'EU. CUNT!i.AC'l'OR S!lAl-L 'l'AK£ CAH.E TO CUT BACK ON THE WATf:IUNG ''l'O PhEVENT THE GiWW'l'H 01' FUNGUS. SOD THAT FAILS TO STAY L,._r_''._;~_,_~-·~_" __ 1_,~-~~_,_N_ll_~_-~_-~_,;_;~-1~_~_''~~1_1:~_r._::_R_L~'~ACED BY •1•11£ LANDS.CA-PE co-~~I~\CTO~~ 4.04 PLANTING 'l'llliES, SilEUBS, GROU!ill COVEKS, AND VINES cxcr~\/11.'L'lON FOH p1.1.,_N',i,'fNG~ PHl0i{ '1'0 EXCJ\VNPlNG }'OH. PLANT PirPS, Tille AHEA SHALL CONFOHM 'l'O TB£ LINES AN:J GAADES Sl!OWN. VERIFY LOCATION OF UNDl,;RGROUN:J U'l'lLlTlLS, RJ;PAIR AKY DAMAGE DONE TO UTILI'l'Y LINES SliOvlN. IF UTILITY L:NES NOT SHOWN ON 1'HE DHF,W- IhCS Allli ENCOUNTERED, NO'i'IFY THE CONTilf,C'l'ING OFFICCH IMMEDI- l\'l'i'LY. IN THE EVENT T:ll,':' UN\JC:R0ROUl\D CONSThUCTlON 1-;C!l<.K OR (JlJSTEUCTIONS AKE ENCCJJNTERED IN THE PLANTING on:RATION, A;,TLRNATE LOCATIONS WILL BE DONE AT NO EXTRA COST TO 1'HE Qh'NER. l. PLANT PITS: DIG PITS IJY ANY METHOD PROVIDEIJ THAT THE PITS HAV,; VER'nCAL $ICES l\ND FLAT BOTTOMS. WHEN PITS ARE DUG IHTH AN ALJ~ER i\l\D TflE SIDr~S OF '!'HE PITS HF.COME CU\ZED, SCARIFY THE GLAZED SURFACE. THE MINIM\:M ALLOW- ABLE DIMEtiSIONS OF PLAN"l' PI'iS $HI.LL BE AS SHOWN IN DETAILS. lY TIIE PERCOLATION IS SUCH THAT WATER WILL NOT i"JRl\.IN OUT OY THE HOLE OVERNIC;H'r, THE CONTRACTOR SHALL TAKE CAUTION NO'l' 'l'O OVEKWATER PLANTS. NO TR2ES 15 GALLONS AND OVER SHAU, BE PLT,NTED IN A Hou; THAT WILL NOT NATURALLY DRAIN OVERNIGHT AFTER HAVING BEEN HAL?-FII.-I,E;J WlTH WATER. 'l'ESTS SHALL BE CONDUCTED TO MAKE THIS DETERMINATION AND THE LANDSCAPE /dCl-!ITECT NOTIFIED OJ:" TEIS CONDITION PRIOR 'l'O PLANTIN0. 2. Sl:BSOIL DRAINAGE FOR PLAN'!' PITS AND lJEDS; PHOVlDE AS INDICATED. LAY PERFORATED DRAIN PIPE WITH PERFORATIONS DOWN. B, /,LL p;_,l\NTS SilALL BE SE'l' SO THAT, WHEN SETTLED, THEY BEAK Tm; SAME RELATION TO THE JU:QUIRED GRAPE AS THEY BORE TO THE NA'l'URAL Gl<ACE IJEFCRE Bl':IliC TRANSPLANTED. EACH PLANT $HAU, BE PLANTED IN TIIL CENTER OF Tll8 PIT AND BACKFILLED, UNLESS OTHERWISE S!'EOIYIEIJ, WI';'!! Tfl!c pm;PARLD SOIL, NO SOIL WH,L BE PERMITTED AHOUND Tf<cNKS OR STEMS. ALL BROKEN OR FRAYBD ROOTS ShALL bii l'llOPERLY CUT OFF. USE EXCESS TOPSOIL TO FORM WATERINc; BAS DJ• hKOUND PLANT$. ANLND AS DESCiUBED II\ NOTES ANi) DETAILS. l. WATSR THOHOUGHLY WI~H A SOLUTION OF VITAMIN B-1 AND WATER r,;R MANUFACTURER'S SPl-:CIFlCA'l'IONS. 2. GROUND cova:KS AND VINES: DO NOT REMOVE FROM FLATS AND CONTAlNllKS UNTIL IMMEDIT,TELY BEFORE PV1N"rING. SPACE AT nm INT!cRVF,LS IN::>ICATED, SUFFICIENTLY DEEP 1'0 COVER ALL ROOTS. AF'rER PLANTING 100 PLANTS, lHMED1A1'ELY SPRINKLE WITH A SOLUTION Of VITTJ-IIN B-1 AND WATER, !'ER MANUFAC- TURl-;R' S SPECIFICA'l'IONS, UNTIL ENTIRE AHJ-:A 1S SOhKED. S>lODTH PLANTING AREAS AFTER l'i.ANTING TO PROVIDE EVEN, SMOOTH FINISH. C. STA~ING AND GUYING, 1. S'i'AKING: STAKE ALL :'La ,,.241 &,,'. TREES WITH T, ·, STAKE~,. DO NOT INJURE THE BALL OR ROOTS. 2. -t,'tlYINGr-··•Gtff~W=-'l'k£ES · WI'l'H }. -GY.'l'S-EVBMLY $PACE9-•-AROOND ·EAC!! TJtEE·•AS St!OWJ,1..,..I,.N.=o)E;\l'A,ILS. D . .-,M.Y.U::-H-.I.-.-NG---;;:.,.;.: -WW~#-· ·'·Vt:h:bt't'::f tffi· CI: J" R:4'1• T Obhi······F:I,!£· ·.:.€:6:M:i?:LE,'I'.E-~Atw.O-... .S.liRUB ,AREAS HAV&.: .. ~EN.-:·-R;A:N:@··~"'-.it-RB q SJfUJ1-.:::.tttttP:l-,.-Abh-·'-SHRlJHS AND GROUND · CO-VER A m:A · \lllc'1'H ,. ;, '·'£-"'''I;A-cc~,GROl:Jmlcc. '!"lc,lrc&AAK ( .Q -I, " S I Z E ) • NOTE: MULCH Fhh'.tTENSB ··G!l.OEJ:fm .::OV-ER lif<EAS · PRIOR-TO 'PLANTING ·G.Rrn,JND~COVEH. E. Al'PLICATION OF PESTICIDES (INC. HEKBICIDES & FUNGICIDES): APPLY ALL HEHBICIDES AND OTHl:R CHEMICALS JN ACCORDANCE WITH EPA LABEL l-<.ESTRJCTIONS AND JlECCMMENDATIONS AND FEDERAL AND S'l'ATr; LAWS. MAKE DAILY lllil'OR';'S TO THE CONTRACTING OFFICER STATING AKEAS TO BE TREATED WITH EACH CHEMICAi", THE QUAN'l'J'rY APPLIED AND SPRAY MIXTURE OF FORMULATION USED. APPLIChTION A'r £,\CH SITE SHALL BE UNDC:R THE SUPEHVISICJN OF A CERTIFIED APPLICA'i'OR!~ V ::-, , _. ',Y l ,· PART 5 -CCJMPLL'l'ION CJF CUNTHACT 5.01 JU:S'l'ORATION AND CLEAN-UP P,. REMOVE EXCESS W1,STE HATEHIAL IJAILY. WIIEN PLAN'i:ING IN AN AREA rs COMPLETE' CLEAH THE AllliA OF DEBRIS' SPOIL PILES, AND CON- TAINEFS. wm;HE EXISTING TURF AREAS UR PLANTING BEDS HAVE BEEN SCAi{RED OR DAMAGED, RESTORE THESE DAMAGED hREAS TO THEIR OKIGlNAL CONDI'l'ION. KEEP A'!' LEAST 0:-IE PAVED PEDESTRIAN ROUTE TO EACH lJUILDING CLEAN AT ALL TIMES. REMOVE DISUSED EQUIPMENT !,ND IMPLEMENTS CJF SERVICI:: ANO LEAVE EN'.i'IRE AREA INVOLVED IN A NEAT ACCEPTABLE CONDITION SUCH AS TO MEET THE Al'PROVAL OF THE LANDSCAPE ARCilITE~T. 5.02 INSPECTIONS A. 'l'HE LANOSCiWI-: AECHITECT SHALL MAK£ PJ;RIODIC lNSPE:CTIONS DCRING 'l'HE l'L/\N':'Ii,G. TINY PLANTS THAT HAVE NOT llEEtl HANDLED, SPOT'rED DR PLANTEU PRCJ!'ERlaY SHALL BL SUBJECT ~'O flliMOVAL BY Tl!F; LANDSCAPE AKCHITECT OR HIS REPl\ESENTA'rIVE, AND 1'l!EY SHALL, IF NCCESSARY, BE llliLOCl,TED AS DJ RECT;::D AS l'AKT OF THk; CONTRACT. 5. 0 3 MAINTENANCE PE,UOD A. DU'INJTION, TH,; MAINTENANCE >'ERIUD SHALL BEGIN ON 'THE DATE THA'r THi:: OWNER OR DULY APPOINTED REP]-{ESENTATIVE INSPECTS AND GIVES WRI'.:'TEN PHOVISION!,L ACCl,PTANCE OJ;' THE WORK AND $!!ALL CONT IN UL FOH ~,,□ DAYS FKlM THAT DA'l'E. THE DA'J'C FOR ACCEPTANCE OF BOXJ::D ':'REl:S SHALL BE S£T AT 12 MONTHS FKOM THAT DATE. ll. MAlNTENANCE: Ml\INTAIN ALL PLANTING AllliAS IN A \/IGOKOUS, TIIRIV- INl, CONDITION B'( WATERING, CUl.'l'IVATING, SPRAYII, , , WhSIIING OFF WALKS, AND ANY OTUER NECESSAHY OPERATIONS I .,!UNG THE P.NTIRE PEKIOD Of THE INS'~ALLATION AND UNTIL FH .. 'L ACCEPTANCE BY 'l'Hl: LANDSCAPE AHCHI'rEC'l'. C. COtH'RJ\CTOH SliALL CONTINUOUSLY MAINTAIN &,L ARE" INCLUDED IN THE CCJNTHACT DURING nIE PROGRESS Of' TH£ WOh:,. 'l'HHOUGH THE t:STA!lLISHMEl\T PEKlCD, AND UNTIL FINAL ACCEPTAN' ., OF THE WORK. D. 'J111E EN'l'IR£ PitOJLC:'l) SdALL B'"' SA'fISFACrrOHILY M.J\L'.'l'A.INED FOR A PEKIOJJ OF T''>·-·r CALENDAH DAYS, COMHENCING FRCM THE 1'IME ALL ITJ::MS OF IRHIGhTION AND LANDSCAPE !?LANTING WORK HAVE BEEN COM- PLETED AS SPC:CIFIED IN TH,; FORCGOING ARTICLES 01:' THESE SPECIAL PROVISION$ AND TO THE SATISFACTION CJF THE OWNER. E. ESTABLISHMENT WORK INCLUDLS ALL MOWING, W.',1'J;l<ING, WEEDING, HESEEDING, MUL,CHING, CULTIVATING, SPRAYING, AND ~"RIMMING NEC- ESSAEY TO BiUN0 TIU; PLANTED AREAS TO A HCALTHY GHOhING CONDI- TICK, AND ANY ADDITIONAL WORK NEEDEIJ TO KEEP THE AREAS NEAT, EDGED, AND ATTl\ACTIVE. G. II . WATER Gli.ASS UNTlL ACCt:PTANCE OF WORK. 1'1IE AREAS SBA LL BE KEPT MOIST, BUT NCT GLISTENING WE•r, UKTIL TIME FOR THE FIRS1' CUTTING Of GKi'oSS. AfTER FIRST CUTTING, WATER LAWN TO !1AINTAIN A THRIVING CONDITION. RESEEDED AREAS 1'clAT DO NOT SHOW PROMPT G£RMINATION Sf!ALL BE AGAIN RESEEDED AT TEN DAY INTERVALS. ';'HJ:. CON'i'RACTOR SHALL MAINTAIN TllE LAWN ARicAS UN~'IL AN EVEN, CLOSE STAND OF GAASS HAS BEEN OBThlNED AND FOR AT LEAST THIRTY DAYS. DURING THE PLANT LSTABLlSHMENT PERIOU, ALL PLANTS AND PLANTED AREAS SHALL BE KEPT WELL WI.:ED-F.Rlm AT F,LL TIMES. WEEDS, DA!.-LAS AND JOHNSON GRASS, AND BERMUDA Gl\ASS SHALL BE REMOVED AND DIS!'OSED OF. PAY SPECIAL ATTENTION TO WATERING SLOPES PLANTED IN LAWN ON THE WINDWARD hND/OR SUNKY SIDE SO THAT L/\WN v/ILL BE AllEQUA'.('ELY WATERED AT ALL TIMf;S. Till: LAWNS SHOULD BE CDGED WHENEVER NECESSARY. THE GRASS SHALL BE MOWED WITH SHARP AND ADJUSTED MOWERS BEFORE IT EXCEEDS 2" IN HEIGHT. THE GJ\ASS WILL BE CUT TO NOT LESS THAN l½", AND K. L. M. N . o. P. R. ANY DAY THE CONTRACTOR FAILS TO ADEQUATELY WA1'ER, REPLACE UNSUITllBLE PLANTS, WEED, AND OTHER WORK DETERMINED TO BE NECESSARY BY THE ARCHITECT, WILL NOT BE CREDITED AS PART OF 'l'HE ESTABLISHMEN'r PCRIOD. DURING THE ESTABLISHMENT PERIOD, ANY !'LANT I NDICAT •, • WEAKNilSS OR PROBABILITY OF DYING, SHALL BE REPLACED BY THE CONTRACTOR AT HIS OWN EXPENSE, ALL BASINS AROUND SHRUBS AND TREES SHALL BE Ml\INTAINED AT A FOUR INCH DEPTH THROUGHOUT ESTABLISHMENT PERIOD, UNl,ESS OTHERWISE INSTRUCTED BY THE OW'NER OR HIS REPRESENTATIVE. TllliE STAKES WHICH FOR ANY REASON ARE DAMAGED OR RENDERJ:'.D INADEQUATE FOR SUPPORT SHALL BE REPAI]-{ED AND RESTO!lliD TO THEIR ORIGINAL CONDITION. CONSTANT DILIGENCE SHALL BE MAINTAINED TO DETECT THE PRESENCE OF DISEASE, INSECTS, AND/OR RODENT INFESTATIONS AND J?ROPEH PREVENTATIVE OR CONTROL MEASURES TAKEN, ALL SHRUBS AND TREES SHALL BE MAINTAINED IN '/'HEIR NATURAL SHA!'ES. TALL OR SCRAG0LY BRANCHES SHALL BE THINNED OUT WHERE NECESSARY. IN NO CASE $HALL TREES OR SHRUBS BE TRIMMED BY HEADlNG OR SHEARING. ANY PLANTS SEVERELY PRUNED IN THIS MANNER SHALI, BE REMOVED AND REPLACED AT CONTRACTOR'S EXPENSE. ON THE DAY OF THE ESTABLISHMEN1' PERIOD, ALL LAWN AiillAS SHALL Rl'cCEIVE TOP DRESSING OF " POUNDS UF 16-1&-8 COMMERCIAL FERTILIZER PER 1,000 SQ. FT. ON 'i'ltE ll-O!P~-·•.!lA-l/C.,. QF 'fi!E · -ES1".~.l!LI ~!01'· PBRHIB rc·ALl, LAWN-ANO &ROUND COVER AltlsAS--srn.,~; ~I', i (); . m,rnm;.;,-.,p:-;1,}:i(J;..~ -0¥7. i;:~.a-s COMMERC·lAl-.. FElrnb:1ZGR i £.k, -r,-ooe,.,.-,s-ch F!I'. $. A'r COMPLETION OF ESTABLISHMENT PERIOD, ALL AREAS INCLUDED lN THE CONTRACT SHALL BE SUBSTANTIALLY CLEAN AND FJU:C OF IJ£BRIS AND SEEDS. AI,L PLANT MATERIAL$ SHAI,L BE LIVE, HEALTHY, AND FREE OF INF!lS'l'ATIONS. T. ANY EROSION 10R SLIPPAGE OF SOIL CAUSED BY WATERING SHALL BE iIBPAIRLD BY THE CONTRACTOR AT HIS EXPENSE. U. /\LL WALKS, CURBS, AND GUTTERS SHALL BE KEPT CLEAR (JJ:' DEBRIS, MUD, DUST, AND STANDIN0 WATER BY SWEEPING, MOPPING, OR HOSING DOWN AS REQUIRED TO MldNTAIN CLEANLINESS THROUGHOUT. END OF, SECTION • r I' : RCE REVIEWED BY: INSPECTOR ~-~illlll■lll--jlMIIJ llllld11iliiil.sit11 ,_ tllllJJI• S!iil • 1111111-mr "AS BU I LT" EXP. DATE DATE t------------t--+------------+-----1---+-~f----1~8 CITY OF CARLSBAD I SHSEETS I ~_!!J PLANNING DEPARTMENT ;==:'....:==========:::'..':::=::::::: 4584 ADAMS STREET PE 2.91" ~LANTING SPECIFICATIONS APP~6.({' f, f ~~o..__ _ ___l,!"._-//-y;J.- AS~NT PL,;i,,,NG DIRECTOR, 0 A TE DATE INITIAL ENGINEER Of WORK REVISION DESCRIPTION DATE INITIAL INfllAL 01HER IIPPROVAL QTY APPROIIAL DWN BY: PROJECT NO. DRAIMNG NO. CHKD BY: __ _ RVWD BY: HOP 91-21 325s4 L • 4