Loading...
HomeMy WebLinkAbout2022 LEE CT; ; CBR2019-1199; PermitBuilding Permit Finaled Residential Permit Print Date: 04/09/2021 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: 2022 LEE CT, CARLSBAD, CA 92008-2762 BLDG-Residential Work Class: 2053304500 Track#: $108,498.25 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Addition Description: O'NEAL: 245 SF ADDITION// 1,275 SF REMODEL// 515 SF OF NEW PATIO FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Property Owner: RORY AND MARCIA O'NEAL 2022 LEE CT CARLSBAD, CA 92008 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1 -Medium BLDG SW PPP PLAN REVIEW FEE TIER 1-MEDIUM Total Fees: $1,953.61 Total Payments To Date: $1,953.61 (city of Carlsbad Permit No: CBR2019-1199 Status: Applied: Issued: Finaled Close Out: Inspector: Final Inspection: Balance Due: Closed -Finaled 05/15/2019 06/16/2020 TAlva 04/09/2021 AMOUNT $657.95 $460.56 $66.00 $175.00 $92.00 $182.00 $5.00 $14.10 $246.00 $55.00 $0.00 Please take NOTICE that approval of your project includes the 11lmposition" of fees, dedications1 reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-85601 I www.carlsbadca.gov Ccicyi •f Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Check CQR~01'1"1\99 Est. Value JfJOi,9~i.2.5 PC Deposit -------- Date _ _._.5'+/....,15,.1.1/u.l°I_.___ -..,_..,.__ Patio SF, .--Garage SF ·hM-M"!'reate an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __ ~emodel: /1,, 7 s SF of affected area Is the area a conversion or change of use? Yes e D Pool/Spa: E-)(1'sh~F Additional Gas or Electrical Features? .eir&fef ~~Jti~· 2W1 ~> D Solar: ___ KW, ~odules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes CJ.V E?-1( , f.4,L,1~ f fi, U111l,IM'"1 □ Reroof: l-'(-. Vd,f tp r~n cg-"'Plumblng/Mechanlcal/Electrical Only: r~ l'l-1. • J? 1e H,,, r, 11M . w I > ,.,_J::. ½W D Other: ___________________________ _;_ _____ _ (Sec. 7031.S Business and Professions Code: Any·City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to Its issuance, atso requires the applicant for such permit to flle a signed statement that he/she Is llcensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commend ins with Section 7000 of Division 3 of the Business and Professions Code} or that he/she Is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a pennlt subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602--8558 Email: Building@carlsbadca.gov B--1 Page 1 of2 Rev. 06/18 ( OPTION A ): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury~ of the following declarations: CJ I have and wlO maintain a certificate of consent to selMnsure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit ls Issued. □ I have and wUI maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit ls Issued. My workers' compensation Insurance carrier and policy number are: Insurance Company Name: ___________________ _ Polley No. ___________ Expiration Date: ________ _ □ Certificate of Exemption: I certify that In the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject ta the workers' compensation laws of Califomla. WARNING: Failure to MCI.I._ workers compansatlon coverap ls unlawful, and shall subject an emplofer to afmlnal penaltlos and dvll fines up ,o $100,000 00, In -tho to the cost of r:ompensatlon, damages as~ for In Section 3706 of the Labo< Code, interest and atmrney's fees. CONTRACTOR SIGNATURE: ________________ □AGENT DATE: _____ _ ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: □ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure Is not Intended or offered for sate (Sec. 7044, Buslness and Professk>ns Code: The Contractor's License law does not apply to an owner of property who builds or Improves thereon, and who does such work himself or through his own employees, provided that such improvements are not Intended or offered for sale. If, however, the building or improvement Is sold within one~ completion, the owner-builder will have the burden of proving that he did not build or Improve for the purpose of sale). ,g{," as owner of the property, am excfuslvely contracting with licensed contractors to construct the project {Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and contracts for such projects With contractor(s) 11<:ensed pursuant to the Contractor's Lkense Law). □ I am exempt under Section _______ Business and Professions Code for this reHon: 1. I personally plan to provide the major labor and materials for construction of the proposed property Improvement. □ Yes □ No 2. I (have/ have not) signed an appllcation for a bulldln,: permit for the proposed work. 3. r have contnK:ted with the follOWing person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major wort (lndude name/ address/ phone/ contractors' Ncense number): s. I wm provide ;;;;~ifiiif.eiiwoiioir'k:k,1biiiuti7tiihiaaiiiveuiiih Ide the work indicated (Include name/ address/ ne / of work): DATE:\\ 22-, Zs:Y,':j CONSTRUCTION LENDING AGENCY. IF ANY: I hereby affirm that there is a construction lending asencv for the performance of th■ work this permit is Issued (Sec. 3097 (i) CMI Code). Lender's Nmne: ___________________ Lender's Address: __________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: J./ A- ts the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or r1sk management and prevention program under Sections 25505, 25S33 or 25534 of the Presley•Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the faclHty to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF Alff OF'fflE ANSWERS ARE YES, A FINAL CERTIACATE OF OCCUPANCY MAY NOT BE ISSUED UNlESS THE APPLICANT HAS MET OR IS ME£TING 1lfE REQUIREMENTS OF THE 0Ffta OF EMERGENCY SERVICES AND THE AIR POU.U',110N CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above Information Is correct and that the lnformatton on the plans is accurate. I agree to comply wfth all Oty ordinances and State laws relatln11 to bu riding construction. I hereby authorize representative of the City of Carlsbad ,o enter upon the above mentioned prope,ty for lnspectloo purposes. I A1SO AGREE TO SAVE. INDEMNIFY AND KEEP HARMl.WlliE OTY OF CARLSBAD AGAINST All UABILmES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINSTSAJD OTY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit Is required for excavations over S'a deep and demolltlon or c:onstruct1on of structures over 3 stories In height EXPIRATION: Ewry permit Issued by the llulldlng Offlcial under the pfCYlsions of this Code shall e,cpire by !imitation and become null and ,old W the buHdlng"' work authorized by such permit is not commenced within 180 days from the date of such permit or If the building or work authorized by such permit is suspended or abandoned at anytime after the work Is commenced for a period =•(Sectl~.4 U~lngC,). APPUCANTSIGNATURE: ~17 DATE: ) /tt/t 1 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Page 2 of2 Rev. 06/18 PERMIT INSPECTION HISTORY for (CBR2019-1199) Permit Type: BLDG-Residential Application Date: 05/15/2019 Owner: COOWNER RORY AND MARCIA O'NEAI Work Class: Addition Issue Date: 06/16/2020 Subdivision: CARLSBAD TCT#85-36 Status: Closed -Finaled Expiration Date: 06/01/2021 Address: 2022 LEE CT IVR Number: 19087 CARLSBAD, CA 92008-2762 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Friday, April 9, 2021 Page 3 of 3 PERMIT INSPECTION HISTORY for (CBR2019-1199) Permit Type: BLDG-Residential Work Class: Addition Application Date: 05/15/2019 Owner: COOWNER RORY AND MARCIA O'NEAI Issue Date: 06/16/2020 Subdivision: CARLSBAD TCT#85-36 Status: Closed -Finaled Expiration Date: 06/01/2021 Address: 2022 LEE CT IVR Number: 19087 CARLSBAD, CA 92008-2762 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspectlon Inspection 11/16/2020 11/30/2020 04/09/2021 11/16/2020 Checklist Item BLDG-Building Deficiency Status COMMENTS November 6, 2020: 1 . Shower pan/hot mop shower enclosures.shower stall areas -approved. BLDG-84 Rough 143408-2020 Passed Tony Alvarado Combo(14,24,34,44) Checklist Item COMMENTS BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLDG-16 lnsulatlon 143738-2020 Passed Paul Burnette Checklist Item COMMENTS BLDG-Building Deficiency 11/30/2020 BLDG-17 Interior Lath/Drywall 144897-2020 Passed Tony Alvarado Checklist Item COMMENTS BLDG-Building Deficiency November 30, 2020: 04/09/2021 BLDG-Final Inspection Checklist Item BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final 1. Drywall/gypsum board type and nailing pattern -approved. 154609-2021 COMMENTS April 9, 2021: Passed Tony Alvarado 1. Final structural/building, mechanical, plumbing, and electrical scope of work, per architectural structural plans and detail specifications -approved. April 9, 2021: 1. Final structural/building, mechanical, plumbing, and electrical scope of work, per architectural structural plans and detail specifications -approved. April 9, 2021: 1. Final structural/building, mechanical, plumbing, and electrical scope of work, per architectural structural plans and detail specifications -approved. April 9, 2021: 1. Final structural/building, mechanical, plumbing, and electrical scope of work, per architectural structural plans and detail specifications -approved. Friday, April 9, 2021 Passed Yes Complete Passed Yes Yes Yes Yes Complete Passed Yes Complete Passed Yes • Complete Passed Yes Yes Yes Yes Page 2 of 3 Building Permit Inspection History Finaled {city of Carlsbad PERMIT INSPECTION HISTORY for (CBR2019-1199} Permit Type: BLDG-Residential Work Class: Addition Application Date: 05/15/2019 Owner: COOWNER RORY AND MARCIA O'NEAI Issue Date: 06/16/2020 Subdivision: CARLSBAD TCT#85-36 Status: Closed -Finaled Expiration Date: 06/01/2021 Address: 2022 LEE CT IVR Number: 19087 CARLSBAD, CA 92008-2762 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 07/17/2020 07/17/2020 BLDG-11 133166-2020 Passed Tony Alvarado 09/17/2020 11/06/2020 Foundatlon/Ftg/Plers (Rebar) Checklist Item COMMENTS BLDG-Building Deficiency July 17, 2020: 09/17/2020 BLDG-23 Gas/Test/Repairs 1. Footings-foundationfslab steel reinforcement rebar and pad footings approved for engineered plans, details, and specifications. 138695-2020 Passed Tony Alvarado BLDG-81 Underground 138550-2020 Passed Tony Alvarado Combo(11, 12,21,31) Checklist Item BLDG-21 Underground-Underfloor Plumbing COMMENTS September 17, 2020: 1. Underground plumbing waste lines under test -approved. BLDG-83 Roof Shoaling, 138551-2020 Exterior Shear (13,15) Passed Tony Alvarado Checklist Item COMMENTS BLDG-13 Shear Panels-HD (ok September 17, 2020: to wrap) 1. Shearwall type/nailing pattern, earthquake hold downs, and metal connectors, per engineered plans and specifications-approved. BLDG-15 Roof Sheathing-Reroaf 11/06/2020 BLDG-17 Interior Lath/Drywall Checklist Item September 17, 2020: 1. Roof sheeting tighUnailing pattern approved. 2. Metal connector straps (Sn metal straps across ridge nail to each side of roof rafters-approved per engineered details. 143409-2020 Passed Tony Alvarado COMMENTS BLDG-Building Deficiency November 6, 2020: BLDG-27 Shower Pan/Tubs 1. Interior tile lath for bathroom shower tub enclosure areas-approved. 143410-2020 Passed Tony Alvarado Friday, April 9, 2021 Complete Passed Yes Complete Coinplete Passed Yes Complete Passed Yes Yes Complete Passed Yes Complete Page 1 of 3 Ghostrider inc. PH. 760-473-5052 Fax 619-367-5791 E-mail, twghostrider01@yahoo.com cuENT Rory & Marcia Oneal DATE 8/21/2020 ARCHITECT Caroline Dooley Architect 550 Laguna Dr. Carlsbad; Ca Any Where Any Time Around the World, Around the Clock P.O. Box 1120 Fallbrook, CA 92088 E-mail, Sdmosch@gmail.com ,' '', I I ' ~ w~ :_ I -I ·-I _1 r : ~ 'i ! J l . , 1 -~ PROJECT O'neal Remodel ADDRESS 2022 Lee Court cIn Carlsbad, CA 92008 JOB# Ghostrider, Inc. ENGINEER Paul Cristensen San Diego 760-207-1885 BUILDING PERMIT/OSA/OSHPo# C8R2019-1199 PLAN FILE# Not Applicable CONTRACTOR Datum Builders w. o. # Not Applicable INSPECTION SAMPLES QTY. MATERIAL DESCRIPTION CHECKLIST Epoxy All-thread Sheer Panel System Concrete, PSI: # Unknown/Existing Approved Plans Not Available Epoxy Type: # Simpson SET-XP (ESR 2508) Compressed Air Blow,Brush,Blo"' Batch Number: # 1000089402, Exp. 05/2022 Bottle Brush Nylon 1/2" Dia. Threaded-Rod: # ¾" & 5/8" (Galv.) Edge Distance Approved Plywood: # 15/32" Exposure 1 Field Nailing 12" O.C Nails: # 8D Edge Nailing 2" O.C. Anchor Bolts: # 5/8" Dia. @ 24" O.C. Weather Sunny Bright REMARKS: Inspected epoxy all-thread of Holdowns & added anchor bolts for schedule D & A sheerwalls on the Northwest side of project. Contractor used¾" Dia. (Galv.) all-thread for HDU8 holdowns and 5/8" Dia. (Galv.) all-thread for HDU2 holdowns and anchor bolts. Contractor drilled 7 /8" Dia. X 15" deep holes for HDU8's. Contractor drilled¾" Dia . X 10" deep holes for HDU2's. Contractor drilled ¾" dia. X 5" deep holes for anchor bolts. Contractor used clean dry compressed air & a nylon bottle brush to clean holes. Holes were filled and rods installed. Inspected sheer nailing for Schedule D sheerwalls (2" nail spacing) on the Northwest side of project. Nailing was in compliance with the approved drawings for the walls mentioned above. CERTTFICATTON OF COMPLIANCE: To the best of our knowledge, all of the reported worlc, unless otherwise noted, substantially complies with approved plans, specifications and applkable sections of the building codes. For this report to be wlld It must have a final report, signed by the special Inspector, stating •Flnol Report of Inspection and materlol testing". Without a final report this document Is inwlld. This report covers the locations of the work reported only and doesn't constitute englnttrlng opinion or project control. !Time in, Time out: Authorization: _..:..T.:....:H=E-=D:..:E:.:...P-=U....:.TY--=-=-S _______ _ Taylor White A. W.S. & .C.C. & San Diego 1287: This Is not o government form. The Federal, State. County and City seals only signify that Inspections ore conducted under Federal, State, County and City Codes {2013, C.8.C.). This document Is not used for advertising. marketing or promotions. This document is used to convey compliance with the Codes. Ghostrider, Inc. 01-2008. Rev. 118) 9/201S DATE: July 24, 2019 JURISDICTION: Carlsbad PLAN CHECK#.: CBR2019-1199 PROJECT ADDRESS: 2022 Lee Ct. PROJECT NAME: O'Neal Residence ✓• EsG1I A SAFEbu1lt Company SET: II Addition/Remodel ~ APPLICANT 1 JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. IZJ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: IZJ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: / Telephone#: Date contacted: (by:9<') Email: Mail Telephone Fax In Person REMARKS: 1. The de/igner stated that the Building Official will not require a soils report for this project. Ple-3t. ~\fYf 2. The structural sheets must p._e~.9y the engineer. By: Kurt Culver µ ~ Enclosures: ctJ' / EsGil 7/18/19 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: June 3, 2019 JURISDICTION: Carlsbad PLAN CHECK#.: CBR2019-1199 PROJECT ADDRESS: 2022 Lee Ct. PROJECT NAME: O'Neal Residence ✓• EsG1I /1,. \Iii l:.bw!t Company SETI Addition/Remodel □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Caroline Dooley D EsGil staff did not advise the applicant that the plan check has been completed. cg] EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Caroline Dooley Telephone#: 760-815-8748 Date contacted: (by: ) Email: caroline@CarolineDooley.com Mail Telephone 0 REMARKS: By: Kurt Culver EsGil Fax In Person Enclosures: 5/16/19 9320 Chesapeake Drive, Suite 208 ♦ San Diego. California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBR2019-1199 June 3, 2019 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR2019-1199 PROJECT ADDRESS: 2022 Lee Ct. FLOOR AREA: +760 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: June 3, 2019 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad STORIES: 1 HEIGHT: n/c DATE PLANS RECEIVED BY ESGIL CORPORATION: 5/16/19 PLAN REVIEWER: Kurt Culver This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e .• plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBR2019-1199 June 3, 2019 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK#.: CBR2019-1199 PREPARED BY: Kurt Culver BUILDING ADDRESS: 2022 Lee Ct. BUILDING OCCUPANCY: R3 BUILDING PORTION Add/Remodel Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code ------------ AREA (Sq.Ft.) cb 1997 UBC Buildin :~' Permit Fee 9. ___ ~ 1997 UBC Plan Check Fee Valuation Multiplier By Ordinance Type of Review: Complete Review DATE: June 3, 2019 Reg. Mod. VALUE ($) D Structural Only 108,498 108,498 I D Repetitive Fee _ ••-,a Repeats D Other D Hourly EsGil Fee tC $40~-~ Comments: Sheet 1 of 1 Carlsbad CBR2019-1199 June 3, 2019 PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. If there is no complying barrier between the pool and any proposed new doors, please show how compliance with section AV100.2 for pool safety will be achieved (i.e. exit alarm; self-closing, self-latching device with the release at least 54" from the floor, etc.). 4. Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. 5. Show on the floor plans the locations of the required smoke alarms and carbon monoxide alarms. 6. All habitable rooms shall be provided with aggregate glazing area of not less than 8% of the floor area of such rooms, per Section R303.1. Natural ventilation shall be provided for all habitable rooms, with the minimum openable area to the outdoors of 4% of the floor area being ventilated. Section R303.1. a) The "Study" previously had a window directly to the outside. Now it won't. Please justify. 7. I am concerned that the "Study" is actually a bedroom (which would then require an emergency egress opening directly to the exterior). In the northeast corner of the room is a notched area that appears to be a closet. This, then, would make the study a bedroom. Carlsbad CBR2019-1199 June 3, 2019 8. Show in the window schedules which windows will have tempered glass, per Section R308.4. Windows C, G, etc. 9. Specify on the plans the following information for the roof materials, per Section R106.1.1: a) Manufacturer's name and product name/number. b) ICC approval number, or equal. 10. Per Carlsbad policy, a soils report is required for this project (the total added floor area exceeds 500 square feet). Please provide. 11. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). 12. Note on plans that surface water will drain away from building and show drainage pattern. The grade shall fall a minimum of 6" within the first 10 feet. Section R401.3. 13. Per Carlsbad ordinance, major residential renovations (defined as renovations/additions having a valuation of $60,000 or more) a minimum of one "EVSE (Electric Vehicle Supply Equipment) ready space" shall be installed. a) The "EVSE ready space" shall have the following: Panel capability, 40A 2 pole breaker, 1" raceway, No. 8 conductors installed to the anticipated charger location. MISCELLANEOUS 14. Sheet A1 .1 says, "Add new masonry fireplace" at the living room. Provide complete detailing for the masonry. Carlsbad CBR2019-1199 June 3, 2019 15. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 16. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 17. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kurt Culver at EsGil. Thank you. STORM WATER POLLUTION PREVENTION NOTES 1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN IS EMINENT. 2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING RAINFALL. 3. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM AGGREGATE. o. AOEQUA TF EROSION .A~!D SEDIMENT CONTROL AND PERIMETER PRU it:(;TION BEST MANAGEMENT PR1\CTICE MEASURES MUST BE INSTALLED AND MAINTAINED. 7. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY REGULATIONS. OWNER'S CERTIFICATE: I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY _lHE CITY OF CARLSBAD. -C\eo..-\ ~\(1/:tv, 9 E-29 STORM WATER COMPLIANCE FORM TIER 1 CONSTRUCTION SWPPP C8R~ol9 -/l3<t BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE Erosion Control Sediment Control BMPs Tracking Non-Stonn Water Waste Management and Materials BMPs Control BMPs Management BMPs Pollution Control BMPs C: -C: C: 0 -0 0 :;:, C: 'O :;:, :;:, ., 'O C: C: "' 0 E C: ., 'O ., 0 0 C: "' -0 2 :, 0 .!: ·.:: .9-0 E C: 0 -L 'O ., 0 ::,; 'O ., E "' L ., --:;:, .!: L :, >, "' L ., c ., ., ., ~ "-L C: ., C: CT 0 C: "' Oc Q_ ., -~ ·.:: -C: ., C: L L w ., C: 0 Best Management Practice* ~ .!: 0 CD L 0 ., 0 L Cl ., > ., 3" ., ,!: 0 C: '-' ., -~ ., 0 :;:, -..c: C: E ., "' "ci C (_) L ., 'O ., j 'O ., ::,; C: ., C: (BMP) Description ➔ ., 0 ., (/) ·e ., "' CD "' C: C: D ::, 'l? -., ~ :, ~ Q) ., -0 0 3" C: LO 'Ow 'O >, 0 ., C: C: 0 fg E :;:, 0 C: D 0 CD (/) ·-"' 0:.:; ., --.... ~o '-' 1l Oo "' ., ., X ::,; D c, D C: ., "' E 0 N a, cn+:i ., ., C: c ., c = L-~., 0 ., -:, ..0 E~ == rn =3 Li ·-"' Q_ ~_g ., ., "-E ~ 1 ks:.:; C: 0 13 ·c: :o e ·.:: ~ "' -'O ..c: C: 0 L ., :, 'O :c Q) ·-'O .B ., 'O 0 0 t'. 'i5 g-'i5 ., ., 0 L-..0 0 _o -~ ~ ·-0 0 0 -., 0 C: 00 OL .B 0 oO ..c: ., -o -.B = C ~6 ., 0 OL = ., ..c: ..0 L .:,o 0 -L -"' ~ct 0 ~o o_ 0 0-0 Cl ~ WD vi (/) (/) '-' G: Cl (/) > (/) <ll CL (/) C: (/) "' CLO CL ::,; (/) ::,; (/) (/) '-' (/)::,; CASQA Designation ➔ r--CX) ~ .... 0 N "' r--CX) N "' .... "' "' 'T "' "' <O r--CX) 'T 'T 'T I I I I I I I I I I I I I I I I I I I '-' '-' '-' '-' w w w w w w w w g:: g:: (/) (/) (/) (/) ::,; ::,; j j ::,; Construction Activity w w w w (/) (/) (/) (/) (/) (/) (/) (/) z z z z ~ ~ ~ Gradina /Soil Disturbance Trench inn /Excavation Stockoilina Drillinn /Rorina 2 Concrete/Asphalt Sawcuttina k/ -',,(_ ...,. X r--. -.... '">< .;,<... ~ Concrete Flatwork ~ Paving ..,. Conduit/Pipe Installation ' Stucco/Mortar Work I, Waste Disposal .... Staainn /Lav Down Area Eauioment Maintenance and Fuelina Hazardous Substance Use/Storaae Dewaterina Site Access Across Dirt Other /list 1: Instructions: 1. Check the box to the left of all applicable construction activity (first column) expected to occur during construction. 2. Located along the top of the BMP Table is a list of BMP's with it's corresponding California Stormwater Quality Association (CASQA) designation number. Choose one or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column. 3. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project. PROJECT INFORMATION Site Address: ____________ _ Assessor's Parcel Number: --------- Emergency Contact: \ Namw~'==f O 1/\c,,_ 24 Hour Phone:709 -8\S--\Cf'IS Construction Threat to Storm Water Quolity (Check Box) t:e(MEDIUM □ LOW ., -., 0 ~-C: ., ., " E 0 ., 'E "' oO N C: 00 :c::,; <O I j ~ '><" ., -., o-~~ ., E -., ., "' ho C: C: oo '-' ::,; CX) I j ,,,... "><:- Page 1 of 1 REV 11/17 PERMIT REPORT Revision Permit Print Date: 04/27/2021 Job Address: 2022 LEE CT, CARLSBAD, CA 92008-2762 {city of Carlsbad Permit No: PREV2019-0229 Status: Closed -Finaled Permit Type: BLDG-Permit Revision Work Class: Residential Permit Revisi1 Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: 2053304500 Track #: $0.00 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: CBR2019-1199 Plan Check#: Applied: 11/04/2019 Issued: 06/16/2020 Finaled Close Out: 04/27/2021 Inspector: Final Inspection: Description: O'NEAL: COORDINATION OR ARCH & STRUCTURAL BEAM & RAFTER// ADDED STRUCTURAL DETAILS TO PLANS// CHANGES Tl FRAMING OF PATIO & MASTERBEDROOM Property Owner: FEE BUILDING PLAN CHECK REVISION ADMIN FEE MANUAL BLDG PLAN CHECK FEE RORY AND MARCIA O'NEAL 2022 LEE CT CARLSBAD, CA 92008 Total Fees: $335.00 Total Payments To Date: Building Division $335.00 Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov AMOUNT $35.00 $300.00 $0.00 Page 1 of 1 {'cicyof Carlsbad PLAN CHECK REVISION OR DEFERRED SUBMITTAL APPLICATION Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov B-15 Original Plan Check Number Cbf?;;lot 91 -II? ? ProjectAddress cr()8,cx ltt° C0:\)@ Plan Revision Number f'eewc>fl-I) ,;26).'7' I General Scope of Revision/Deferred Submittal: Coof2tllN/ffiorJ OF ltE!Pifitl;CTT/M I/No ~ti~ lA:::nt(L, -Gl{'m'tJ/r.'rtill <2A1.irOPNIA ~ a:: Dier?-: 1'111tsn;;e... CONTACT INFORMATION: Name FefZ/-JA-tJM Phone !Oc:9-· 4-/5'. 1-J-q) Fax~-------- Address /00& I'~ ?efL_ city v,'s-v--Zip EA-- EmailAddress Fe-!2-NANbA CE Q;Lj'i.~ · C..0[0 Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: '§){Plans D Calculations D Soils D Energy D Other 2. Describe revisions in detail rYOtJ fl. o i rv A-n·o N OP li.-fldf{rtCTVRA-t, ~ fSiRj/C iVPAl 13FNn t ~· t? . ~/l ' ff-oQtlJ 4-tRIJ r, i1J ;:;;tA-l I I (},A! ',HJ I -•-' />;/Af(\I"" .,) J Q/J/A ., ,·,.,,,NG-OV(:,(Z ,,-X,'5/ V 7:!. T ,. Does this revision, in any way, alter the exterior of the project? D Yes Does this revision add ANY new floor area(s)? Does this revision affect any fire related issues? D Yes D Yes 'pt_No )2}-No 3. List page(s) where each revision is shown <,,cl_ -:J-5, ;J. 4-:::, C M. 9'-- 4. 5. 6. 7. Is this a com pie e ~ Yes Date J //04) 1_® I Ph: 760-602-27 I 9 Fax: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov DATE: November 18, 2019 JURISDICTION: Carlsbad . ' ,1 SETI j APPLICANT JURIS. PLAN CHECK#.: CBR2019-1199 REV PROJECT ADDRESS: 2022 Lee Ct. PROJECT NAME: O'Neal Residence Addition/ Remodel PREV2019-0229 D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes·. k8'J The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: k8'] EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: I I )lz )1q (by S1/1) Email: Mail Telephone Fax In Person k8'] REMARKS: The structural sheets must be signed by the engineer. By: Kurt Culver EsGil 11/4/19 Enclosures: Previously-approved plans 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBR2019-1199 REV November 18, 2019 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Kurt Culver PLAN CHECK#.: CBR2019-1199 REV DATE: November 18, 2019 BUILDING ADDRESS: 2022 Lee Ct. BUILDING OCCUPANCY: R3 BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance -, Reg. VALUE ($) Mod. 1997 UBC Building Permit Fee 1997 UBC Plan Check Fee .... ! ------, .... ' ------_I D Complete Review -c:7500.a_§) Type of Review: D Repetitive Fee --;;] Repeats • Based on hourly rate Comments: □ Other 0 Hourly EsGil Fee D Structural Only 21 Hrs.@* :~~~~-$-1~2~0~.o:o $240.00/ Sheet 1 of 1