HomeMy WebLinkAbout2675 ROOSEVELT ST; ; CBRA2018-0223; PermitBuilding Permit Finaled
(City of
Carlsbad
Residential Associated Permit
Print Date: 12/01/2020
Job Address: 2675 ROOSEVELT ST, CARLSBAD, CA 92008
Permit Type: BLDG-Associated Permit Residential Work Class:
Parcel#: 2031013801 Track#:
Valuation: $273,201.07 Lot#:
Occupancy Group:
#of Dwelling Units: 1
Project#:
Plan#:
Bedrooms: 3 Construction Type:
Condo
CT140007
1
DEV04098
Bathrooms: 3.0 Orig. Plan Check#: PC2018-0019
Plan Check#:
Project Title: BEACHWALK AT ROOSEVELT
Permit No: CBRAZ018-0ZZ3
Status:
Applied:
Issued:
Finaled Close Out:
Inspector:
Final Inspection:
Closed -Finaled
11/15/2018
12/27/2018
MColl
12/01/2020
Description: BEACH WALK AT ROOSEVELT: BLDG 2 // UNIT 1 //PLANE// 1,664 SF LIV// 429 SF GARAGE// 204 SF DECK
Applicant:
VESTA PROPERTIES
GEOFF MCCOMIC
18181ST AVE
SAN DIEGO, CA 92101-2662
(616) 481-3830
FEE
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Property Owner:
M R CARLSBAD 11 LLC
1818 1ST AVE, # 100
SAN DIEGO, CA 92101
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES -outside CFD
SB1473 GREEN BUILDING STATE STANDARDS FEE
SDCWA SYSTEM CAPACITY CHARGE 2" Displacement
STRONG MOTION-RESIDENTIAL
SWPPP INSPECTION FEE TIER 1-Medium BLDG
SWPPP PLAN REVIEW FEE TIER 1 -MEDIUM
WATER METER FEE 2" Displacement (P)
WATER SERVICE CONNECTION FEE 2" DISPLACEMENT (P)
WATER TREATMENT CAPACITY CHARGE 2" Displacement
Total Fees: $58,234.20 Total Payments To Date:
Building Division
$58,234.20
CoApplicant:
VESTA PACIFIC DEVELOPMENT INC
1818 1ST AVE, # SUITE 100
SAN DIEGO, CA 92101-2662
(619) 481-3830
Balance Due:
AMOUNT
$1,243.70
$800.94
$66.00
$175.00
$92.00
$182.00
$9,562.04
$11.00
$21,416.00
$35.52
$246.00
$58.00
$606.00
$23,148.00
$592.00
$0.00
Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
Permit Type: BLDG-Associated Permit Residenti,
Work Class: Condo
Status. Closed -Finaled
Application Date: 11/15/2018 Owner: MR CARLSBAD 11 LLC
Issue Date: 12/27/2018 Subdivision:
Expiration Date: 01/25/2021
IVR Number: 15490
Address: 2675 ROOSEVELT ST
CARLSBAD, CA 92008
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector Reinspection Inspection
Status
C hccklist Item COMMENTS
FIRE· Building Final 11/30/2020
Building 1-6 are ok AM
12/01/2020 12/01/2020 BLDG-Final Inspection 145036-2020 Passed
Tuesday, December 1, 2020
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
Chris Renfro
Passed
Yes
Passed
Yes
Yes
Yes
Yes
Yes
Complete
Page 5 of 5
0 , 'th -" ""'':.-:JS~-✓ ' z;,f",~ J~;:: ""-~ ~,-~ "::"'✓ ~ Ji+,,:,t ~, ::+.,r'"'''~/4; 'a,-,, -s:,-, '
.: . -·"~ e~11MIT1NsPECTtlii:e1$"f:QJJi io~ ,caRA201s-022s, -.
Permit Type: BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner: M R CARLSBAD 11 LLC
Work Class Condo Issue Date: 12/27/2018 Subdivision:
Status Closed • Finaled Expiration Date: 01/25/2021 Address: 2675 ROOSEVELT ST
!VR Number: 15490 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
07/29/2020 07/29/2020 BLDG-11 134070-2020 Partial Pass Michael Collins Rcinspcction Incomplete
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Building Deficiency 7/29/20, Deck column footing/steel Yes
07/30/2020 07/3012020 BLDGwElectrlc Meter 134268-2020 Passed Michael Collins Complete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency EMR emailed to SDGE, see card for Yes
additional notes.
08131/2020 08/3112020 BLDG-Final Inspection 137062-2020 Failed Paul Burnette Reinspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Ne
BLDG-Plumbing Final Ne
BLDG-Mechanical Final N,·,
BLDG-Structural Final /,\, d\;
BLDG-Electrical Final t•J .. ,
09/01/2020 09/0112020 BLDG-Final Inspection 137193-2020 Partial Pass Paul Burnette Reinsp(Ktion Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 'i
BLDG-Plumbing Final -~1.
BLDG-Mechanical Final Ni,
BLDG-Structural Final Nu
BLDG-Electrical Final Ne,
11/09/2020 11/0912020 BLDG-Gas Meter 143484-2020 Passed Paul Burnette Complete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/13/2020 11/13/2020 BLDG-Final Inspection 143729-2020 Failed Chris Renfro Reinspection Incomplete
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Need fire final prior to building final. ~;
BLOG-Plumbing Final :•J,,
BLDG-Mechanical Final \j1;
BLDG-Structural Final f,/('
BLDG-Electrical Final !\,j(,
11/30/2020 1113012020 BLDG-Fire Final 145019-2020 Passed Adalmira Maldonado Complete
Tuesday, December 1, 2020 Page 4 of 5
Permit lype: BLDG-Associated Permit Residenti, Application Date: 11115/2018 Owner: M R CARLSBAD 11 LLC
Work Class: Condo Issue Date; 1212712018 Subdivision:
Status· Closed -Finaled Expiration Date: 01125/2021 Address: 2675 ROOSEVELT ST
IVR Number: 15490 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
BLDG-84 Rough 113993-2019 Passed Michael Collins Complete
Combo(14,24,34,44)
Checklist ltern COMMENTS Passed
BLDG-Building Deficiency Minor pick up, see card Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Ye:.
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
12/1812019 12/1812019 BLDG-16 lnsulatlon 114201-2019 Passed Michael Collins Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/03/2020 01/03/2020 BLOG-17 Interior 115290-2020 Failed Michael Collins Reinspection Incomplete
Lath/Drywall
Checklist !tern COMMENTS Passed
BLDG-Building Deficiency i'J(l
01/08/2020 01/08/2020 BLDG-17 Interior 115702-2020 Passed Michael Collins Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/10/2020 02/10/2020 BLDG-82 Drywall, 119085-2020 Passed Michael Collins Complete
Exterior Lath, Gas Test,
Hot Mop
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Ye:,
BLDG-17 Interior Lath-Drywall Ye:;
BLDG-18 Exterior Lath and Yr,:;
Drywall
BLDG-23 Gas-Test-Repairs Yes
0712412020 07/2412020 BLDG-11 133772-2020 Partial Pass Paul Burnette Reinspection Incomplete
Foundatlon/Ftg/Plers
(Rebar)
Chee klist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLOG-12 Steel/Bond 133840-2020 Partial Pass Paul Burnette Reinspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Tuesday, December 1, 2020 Page 3 of 5
Penntt Type: BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner: M R CARLSBAD 11 LLC
Work Class: Condo Issue Date: 12/27/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 01/25/2021 Address: 2675 ROOSEVELT ST
IVR Number; 15490 CARLSBAD, CA 92008
•• -••• ... -•--~••-.••--•-~•·•e•-w-•~-•~*-~-•"
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout [~(;
BLDG-34 Rough Electrical Nu
BLDG-44 f\J;;
Rough-Ducts-Dampers
06/25/2019 06/25/2019 BLDG-14 095721-2019 Partial Pass Michael Collins Rei'nspection Incomplete
Frame/Steel/Bolting/We
lding (Docks)
Checklist Item COMMENTS Passed
BLOG-Building Deficiency 3rd floor, floor sheathing and drag nailing YE;s
BLDG-17 Interior 095582-2019 Cancelled Michael Collins Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
09/06/2019 09/06/2019 BLDG-34 Rough 103201-2019 Cancelled Chris Renfro Reinspoction Incomplete
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency ~t,
09/17/2019 09/17/2019 BLDG-13 Shear 104430-2019 Failed Michael Collins Re inspection Incomplete
Panels/HO (ok to wrap}
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready N;)
10/02/2019 10/02/2019 BLDG-13 Shear 106208-2019 Passed Michael Colllns Complete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Exterior only Ye::,
BLDG-Building Deficiency Not ready
12/12/2019 12/12/2019 BLDG-24 Rough/T opout 11367 4-2019 Partial Pass Michael Colllns Reinspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Except tubs/shower Yes
12/16/2019 12/16/2019 BLOG•27 Shower 113995-2019 Passed Michael Collins Complete
Pan/Tubs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Tuesday, December 1, 2020 Page 2 of 5
Building Permit Inspection History Finaled
( City of
Carlsbad
Permit Type; BLDG-Associated Permit Residenti, Applicatlon Date: 11/15/2018 Owner: M R CARLSBAD 11 LLC
Work Class Condo lssuo Date: 12/27/2018 Subdivision·
Status· Closed -Finaled Expiration Date: 01/25/2021 Address: 2675 ROOSEVELT ST
IVR Number; 15490 CARLSBAD, CA 92008
··-----------~·----~
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
02/2512019 02/25/2019 BLDG-21 084488-2019 Passed Michael Collins Complete
U nderg rou nd/U nderflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Waste only to POC Yes
04/1012019 04/1012019 BLDG-11 088471-2019 Failed Michael Collins Rcinspection Incomplete
Foundatlon/Ftg/Plers
(Rebar)
Checklist !tern COMMENTS Passed
BLDG-Building Deficiency Not ready, need electrical sub feed below '·J,
grade
04115/2019 0411512019 BLDG-11 088916-2019 Passed Michael Collins Complete
F OU n datio n/Ftg/Plers
(Rebar)
Chc:ckllst !tom COMMENTS Passed
BLDG-Building Deficiency Ufer ok, 11/4" conduit ran from main meter >Jo
to sub feed pull box location at each unit,
need to verify conductor fill based on type
of conductor/conduit.
BLDG-Building Deficiency Not ready, need electrical sub feed below Nu
grade
0610412019 06104/2019 BLDG-14 093668-2019 Failed Michael Collins Rcinspect1on Incomplete
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready Ne
06105/2019 06105/2019 BLDG-14 093818-2019 Passed Paul Burnette Complete
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready Yes
06117/2019 0611712019 BLDG-84 Rough 094833-2019 Partial Pass Paul Burnette Rcinspcction Incomplete
Combo(14,24,34,44)
Tuesday, December 1, 2020 Page 1 of 5
GEOTECHNICAL I ENVIRONMENT AL I MATERIALS
GEOTEK FIELD TESTING REPORT
PROJECT NO.: 3447-$D3
DATE: 4-10-2019
NAME: Metcalfe
HOURS: ------
CLIENT Vesta Pacific PROJECT Beachwalk at Roosevelt LOCATION Carlsbad ---------
SUPT. Raul Ajinga CONTRACTOR V.i{,/?, /) t..l &-6J
EQUWMENT None --------------------------------------
SUBJECT Foundations for Units listed below
Location Elev. Moisture Dry %, Relative % Required Test No. Content% Density Compaction Compaction
NO TESTS TAKEN
COMMENTS:
Observed soil conditions for following:
Unit I, 2675 Roosevelt. CBRA 2018-0223: Unit 2, 2677 Roosevelt, CBRA 2018-0224
Unit 3, 2681 Roosevelt, CBRA 2018-0225: Unit 4, 2683 Roosevelt, CBRA 2018-0226
Unit 5, 2685 Roosevelt, CBRA 2018-0227: Unit 6, 2689 Roosevelt, CBRA 2018-0228
Unit 7, 2691 Roosevelt, CBRA 2018-0229: Unit 8, 2693 Roosevelt, CBRA 2018-0230
Unit 9, 2695 Roosevelt, CBRA 2018-0231: Unit I 0, 2697 Roosevelt, CBRA 2018-0232
Soil Type
/ Max Test Type
Foundation excavations are in compliance with the geotechnical recommendations, care should be taken to
remove any loose soil/slough in trenches before pouring. Soil should be moist when concrete is poured.
GeoTe / -----------------------------/
Pass or
Fail
SUPERINTEDENT: By: . . . 'lt./z.
COMPANY: Page
! INSPECTION SEJlVICES I
3406 Texas Street
San Diego, CA, 92104
619-261-9022
desmond@Kingisi.com
www.Kingisi.com
SPECIAL INSPECTION DAILY REPORT
Special Inspection Reports shall be prepared on a Daily Basis. All Non-Compliant conditions must be reported
IMMEDIATELY to the Superintendent. Each Inspection Report shall be completed and signed by the Special
Inspector conducting the Inspection / Testing.
Project Name: Roosevelt Street Apartments Date: 7-29-20
Time Arrived: 9a.m. Hours:
Project Location: 2675 Roosevelt St Carlsbad Time Departed:
Contractor: Vesta Pacific Architect: MLA
Sub-Contractor: Engineer: Gougl
Inspection / Material Description
Samples
Ticket No#: AirTemo : !concrete Temo : @ Mins. lSlumo:
881126 74 I a5 so I 5•
Approved Drawings: Included
8
Work Inspected: Inspection and observation of reinforcement and concrete placement at Building 1, Building 6 and Building 9 caissons along ==~'==~::::::.... __________ Roosevelt St. Contracior removed-all water-from-the footings-with a pum1>7No clearance or coverage lssueSc--Reinforcement-verifled
secured property in place. Hanson mix design #3011100 was pumped into clean, debris free footings and consolidated with a vibrator
-----------thenrnanuallyfinished. One set ol 5 cylinders was o6!liineafor estiiigan(lp aceariexflolneooitaing rgarage. ery c ean wo ~
Progress continue ... -... -.--------
______ _.,eport emailed.to ragulnaga@vestapaclflcdevelopment.co .. ----------------
WORK: ~WAS WAS NOT
INSPECTED I CC ANCE WITH THE REQUIREMENTS
OF THE AP PRO DOCUMENTS.
THE WORK INSPECTED:
Signature of Special Inspector:
MATERIAL SAMPLING:~ WAS NOT WA
INSPECTED IN ACCORDANCE WITH HE REQUIREMENTS
Print Name: Brandon Leonard
CERTIFICATION #: sp114os
OF THE APPROVED DOCUMENTS.
LAB 10 ATTACHED, SAMPLES SCHEDULED FOR PICK-UP Signature of Superintendent:
KINGI I nrsPEC a 10N mv.c:zs j
SPECIAL INSPECTION DAILY REPORT
3406 Texas Street
San Diego, CA, 92104
619-261-9022
desmond@Kingisi.com
www.Kingisi.com
Special Inspection Reports shall be prepared on a Daily Basis. All Non-Compliant conditions must be reported
IMMEDIATELY to the Superintendent. Each Inspection Report shall be completed and signed by the Special
Inspector conducting the Inspection/ Testing.
Project Name: Roosevelt Apartments I Date: 09/26/19
Build inn Permit#: Build #2 / Unit #1: CBRA201 B-0223 Time Arrived: 1030am
Proiect Location: 2675 Roosevelt ::;treet, t;arIsoaa, VA, 92008 Time Denarted:
Contractor: Vesta Pacific Development Architect:
Sub-Contractor: UPF Engineer:
Inspection / Material Description Sheathing, Anchors, nailing, straps, clips
Samoles
Ticket No#: AirTemn: I Concrete Temn: @ Mins. lSlumn:
I I
Approved Drawings: SN• 1 , General notes
Work Inspected: Inspection and Observation continues for Interior and Exterior Shearwalls.
Verified stamped sheathing secured in place, All nails driven flush and staggered.
Walls #2: 8d's@4/12, #3:3/12. #4 and #5: 2/12.
All Header, Straps, Blocking, A35 Clips and Brackets per Shearwall Schedule.
Holddown / anchors in place per plan schedule, engineers details.
Hours: 4
Note : Partial interior inspection, All party walls: After plumbing, electrical, gas placement and insulation will be
palace and wall closed, Fire stop @10'0".
City inspector will verify prior to building being rapped.
Report emailed to Super Raul
WORK: f/~ ~----
INSPECTED l~:c.ceFfuANCE WITH THE RE~~EMENTS
OF THE APPROVED DOCUMENTS.
MATERIAL SAMPLING:-·
INSPECTED IN ACCORDANCE WITH THE REQUIREMENTS
OF THE APPROVED DOCUMENTS.
LAB ID ATTACHED, SAMPLES SCHEDULED FOR PICK-UP
i
THE WORK INSPECTED: BiDiP Nor MffI
Signature of Special Inspector: ~
Print Name: Desmond King
CERTIFICATION#. SD #1169, ICC #8132156
Signature of Superintendent·¥;
GeoTek, Inc.
I 548 North Maple Street, Corona. California 92880
(95 I) 710-1160 Office (95 I) 710-1167 Fax www.geotekusa.com
DAILY INSPECTION REPORT
CLIENT: Vesta pacific development PROJECT NO: 3447-SD -------------------------------------PROJECT: Roosevelt ?t;/"75"' DATE: 04/10/19
PROJECT LOCATION: .c .. =:_R..;oo.c.s;..ce_ve..;;lt'--. C'-'•-~;;.;sbc.cad-'"-'C-'-A _________________________ _
CONTRACTOR: Verdugo construction PLANS BY: Gouvisengineer DATED:
BUILDING PERMIT NO: c.BtZ 11 :iotB-02.23 APPROVED BY: CaMbad PC2018-0CJ19 DATED:-----
1YPE OF INSPECTION: Rebar SHEETS & DETAILS: -"=---------
LOCATION OF INSPECTION: Sea below -""'-'="'-------------------------------
The following items were observed and / or tested:
Inspection and observation continues for SOG / FTG reinforcement tor Building #2 Units 1 &2, building #3 units 3,4,5, building #1 units 8&9, Buliding #4
units 6,7, 10 and 11.
Permits #CBRA2018-0223, CBRA2018-0224, CBRA2018-0225, CBRA2018-0226, CBRA2018-0227, CBRA2018-0230, CBRA2018-0231,
CBRA2018·0228, CBRA2018-0229, CBRA2018-0232, CBRA2018-0233
Verified rebar is securely tied, with laps and clearance in place. #3@24" ocew, Cont (2)#4 TB, reinforcement for spread FTGs,
All Pad FTGs verified, P3, P4, PS and P7 per Pad Schedule.
FTGs are debris free, Anchors in placed for sill plates, strong wall and HDUs,
Visqueen topped with 2" clean sand.
General Notes, SN1, S01, exterior FTGs, foundation plans, Holddowns schedule
2500 psi Concrete scheduled for 04f11!19@0700am TBD.
Raguinaga@vestapacificdevelopment.com
PAGE ____ OF ____ _
E]Work observed during this inspection substantially
complies to approved plans and specifications.
ONot Complete. Work observed is still in progress and
will require additional inspections.
4 Hours: ------------
SUPERVISOR: ~
Signature
Desmond King S0#1169 / 8132156
Print Name
GEOTECHNICAL I ENVIRONMENTAL I MATERIALS