Loading...
HomeMy WebLinkAbout2675 ROOSEVELT ST; ; CBRA2018-0223; PermitBuilding Permit Finaled (City of Carlsbad Residential Associated Permit Print Date: 12/01/2020 Job Address: 2675 ROOSEVELT ST, CARLSBAD, CA 92008 Permit Type: BLDG-Associated Permit Residential Work Class: Parcel#: 2031013801 Track#: Valuation: $273,201.07 Lot#: Occupancy Group: #of Dwelling Units: 1 Project#: Plan#: Bedrooms: 3 Construction Type: Condo CT140007 1 DEV04098 Bathrooms: 3.0 Orig. Plan Check#: PC2018-0019 Plan Check#: Project Title: BEACHWALK AT ROOSEVELT Permit No: CBRAZ018-0ZZ3 Status: Applied: Issued: Finaled Close Out: Inspector: Final Inspection: Closed -Finaled 11/15/2018 12/27/2018 MColl 12/01/2020 Description: BEACH WALK AT ROOSEVELT: BLDG 2 // UNIT 1 //PLANE// 1,664 SF LIV// 429 SF GARAGE// 204 SF DECK Applicant: VESTA PROPERTIES GEOFF MCCOMIC 18181ST AVE SAN DIEGO, CA 92101-2662 (616) 481-3830 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Property Owner: M R CARLSBAD 11 LLC 1818 1ST AVE, # 100 SAN DIEGO, CA 92101 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFD SB1473 GREEN BUILDING STATE STANDARDS FEE SDCWA SYSTEM CAPACITY CHARGE 2" Displacement STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1 -MEDIUM WATER METER FEE 2" Displacement (P) WATER SERVICE CONNECTION FEE 2" DISPLACEMENT (P) WATER TREATMENT CAPACITY CHARGE 2" Displacement Total Fees: $58,234.20 Total Payments To Date: Building Division $58,234.20 CoApplicant: VESTA PACIFIC DEVELOPMENT INC 1818 1ST AVE, # SUITE 100 SAN DIEGO, CA 92101-2662 (619) 481-3830 Balance Due: AMOUNT $1,243.70 $800.94 $66.00 $175.00 $92.00 $182.00 $9,562.04 $11.00 $21,416.00 $35.52 $246.00 $58.00 $606.00 $23,148.00 $592.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov Permit Type: BLDG-Associated Permit Residenti, Work Class: Condo Status. Closed -Finaled Application Date: 11/15/2018 Owner: MR CARLSBAD 11 LLC Issue Date: 12/27/2018 Subdivision: Expiration Date: 01/25/2021 IVR Number: 15490 Address: 2675 ROOSEVELT ST CARLSBAD, CA 92008 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspection Inspection Status C hccklist Item COMMENTS FIRE· Building Final 11/30/2020 Building 1-6 are ok AM 12/01/2020 12/01/2020 BLDG-Final Inspection 145036-2020 Passed Tuesday, December 1, 2020 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS Chris Renfro Passed Yes Passed Yes Yes Yes Yes Yes Complete Page 5 of 5 0 , 'th -" ""'':.-:JS~-✓ ' z;,f",~ J~;:: ""-~ ~,-~ "::"'✓ ~ Ji+,,:,t ~, ::+.,r'"'''~/4; 'a,-,, -s:,-, ' .: . -·"~ e~11MIT1NsPECTtlii:e1$"f:QJJi io~ ,caRA201s-022s, -. Permit Type: BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner: M R CARLSBAD 11 LLC Work Class Condo Issue Date: 12/27/2018 Subdivision: Status Closed • Finaled Expiration Date: 01/25/2021 Address: 2675 ROOSEVELT ST !VR Number: 15490 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 07/29/2020 07/29/2020 BLDG-11 134070-2020 Partial Pass Michael Collins Rcinspcction Incomplete Foundatlon/Ftg/Plers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Building Deficiency 7/29/20, Deck column footing/steel Yes 07/30/2020 07/3012020 BLDGwElectrlc Meter 134268-2020 Passed Michael Collins Complete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency EMR emailed to SDGE, see card for Yes additional notes. 08131/2020 08/3112020 BLDG-Final Inspection 137062-2020 Failed Paul Burnette Reinspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency Ne BLDG-Plumbing Final Ne BLDG-Mechanical Final N,·, BLDG-Structural Final /,\, d\; BLDG-Electrical Final t•J .. , 09/01/2020 09/0112020 BLDG-Final Inspection 137193-2020 Partial Pass Paul Burnette Reinsp(Ktion Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency 'i BLDG-Plumbing Final -~1. BLDG-Mechanical Final Ni, BLDG-Structural Final Nu BLDG-Electrical Final Ne, 11/09/2020 11/0912020 BLDG-Gas Meter 143484-2020 Passed Paul Burnette Complete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 11/13/2020 11/13/2020 BLDG-Final Inspection 143729-2020 Failed Chris Renfro Reinspection Incomplete Checklist Item COMMENTS Passed BLOG-Building Deficiency Need fire final prior to building final. ~; BLOG-Plumbing Final :•J,, BLDG-Mechanical Final \j1; BLDG-Structural Final f,/(' BLDG-Electrical Final !\,j(, 11/30/2020 1113012020 BLDG-Fire Final 145019-2020 Passed Adalmira Maldonado Complete Tuesday, December 1, 2020 Page 4 of 5 Permit lype: BLDG-Associated Permit Residenti, Application Date: 11115/2018 Owner: M R CARLSBAD 11 LLC Work Class: Condo Issue Date; 1212712018 Subdivision: Status· Closed -Finaled Expiration Date: 01125/2021 Address: 2675 ROOSEVELT ST IVR Number: 15490 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status BLDG-84 Rough 113993-2019 Passed Michael Collins Complete Combo(14,24,34,44) Checklist ltern COMMENTS Passed BLDG-Building Deficiency Minor pick up, see card Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Ye:. BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 12/1812019 12/1812019 BLDG-16 lnsulatlon 114201-2019 Passed Michael Collins Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/03/2020 01/03/2020 BLOG-17 Interior 115290-2020 Failed Michael Collins Reinspection Incomplete Lath/Drywall Checklist !tern COMMENTS Passed BLDG-Building Deficiency i'J(l 01/08/2020 01/08/2020 BLDG-17 Interior 115702-2020 Passed Michael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 02/10/2020 02/10/2020 BLDG-82 Drywall, 119085-2020 Passed Michael Collins Complete Exterior Lath, Gas Test, Hot Mop Checklist Item COMMENTS Passed BLDG-Building Deficiency Ye:, BLDG-17 Interior Lath-Drywall Ye:; BLDG-18 Exterior Lath and Yr,:; Drywall BLDG-23 Gas-Test-Repairs Yes 0712412020 07/2412020 BLDG-11 133772-2020 Partial Pass Paul Burnette Reinspection Incomplete Foundatlon/Ftg/Plers (Rebar) Chee klist Item COMMENTS Passed BLDG-Building Deficiency Yes BLOG-12 Steel/Bond 133840-2020 Partial Pass Paul Burnette Reinspection Incomplete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes Tuesday, December 1, 2020 Page 3 of 5 Penntt Type: BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner: M R CARLSBAD 11 LLC Work Class: Condo Issue Date: 12/27/2018 Subdivision: Status: Closed -Finaled Expiration Date: 01/25/2021 Address: 2675 ROOSEVELT ST IVR Number; 15490 CARLSBAD, CA 92008 •• -••• ... -•--~••-.••--•-~•·•e•-w-•~-•~*-~-•" Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout [~(; BLDG-34 Rough Electrical Nu BLDG-44 f\J;; Rough-Ducts-Dampers 06/25/2019 06/25/2019 BLDG-14 095721-2019 Partial Pass Michael Collins Rei'nspection Incomplete Frame/Steel/Bolting/We lding (Docks) Checklist Item COMMENTS Passed BLOG-Building Deficiency 3rd floor, floor sheathing and drag nailing YE;s BLDG-17 Interior 095582-2019 Cancelled Michael Collins Reinspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No 09/06/2019 09/06/2019 BLDG-34 Rough 103201-2019 Cancelled Chris Renfro Reinspoction Incomplete Electrical Checklist Item COMMENTS Passed BLDG-Building Deficiency ~t, 09/17/2019 09/17/2019 BLDG-13 Shear 104430-2019 Failed Michael Collins Re inspection Incomplete Panels/HO (ok to wrap} Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready N;) 10/02/2019 10/02/2019 BLDG-13 Shear 106208-2019 Passed Michael Colllns Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Exterior only Ye::, BLDG-Building Deficiency Not ready 12/12/2019 12/12/2019 BLDG-24 Rough/T opout 11367 4-2019 Partial Pass Michael Colllns Reinspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency Except tubs/shower Yes 12/16/2019 12/16/2019 BLOG•27 Shower 113995-2019 Passed Michael Collins Complete Pan/Tubs Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes Tuesday, December 1, 2020 Page 2 of 5 Building Permit Inspection History Finaled ( City of Carlsbad Permit Type; BLDG-Associated Permit Residenti, Applicatlon Date: 11/15/2018 Owner: M R CARLSBAD 11 LLC Work Class Condo lssuo Date: 12/27/2018 Subdivision· Status· Closed -Finaled Expiration Date: 01/25/2021 Address: 2675 ROOSEVELT ST IVR Number; 15490 CARLSBAD, CA 92008 ··-----------~·----~ Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 02/2512019 02/25/2019 BLDG-21 084488-2019 Passed Michael Collins Complete U nderg rou nd/U nderflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Waste only to POC Yes 04/1012019 04/1012019 BLDG-11 088471-2019 Failed Michael Collins Rcinspection Incomplete Foundatlon/Ftg/Plers (Rebar) Checklist !tern COMMENTS Passed BLDG-Building Deficiency Not ready, need electrical sub feed below '·J, grade 04115/2019 0411512019 BLDG-11 088916-2019 Passed Michael Collins Complete F OU n datio n/Ftg/Plers (Rebar) Chc:ckllst !tom COMMENTS Passed BLDG-Building Deficiency Ufer ok, 11/4" conduit ran from main meter >Jo to sub feed pull box location at each unit, need to verify conductor fill based on type of conductor/conduit. BLDG-Building Deficiency Not ready, need electrical sub feed below Nu grade 0610412019 06104/2019 BLDG-14 093668-2019 Failed Michael Collins Rcinspect1on Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready Ne 06105/2019 06105/2019 BLDG-14 093818-2019 Passed Paul Burnette Complete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready Yes 06117/2019 0611712019 BLDG-84 Rough 094833-2019 Partial Pass Paul Burnette Rcinspcction Incomplete Combo(14,24,34,44) Tuesday, December 1, 2020 Page 1 of 5 GEOTECHNICAL I ENVIRONMENT AL I MATERIALS GEOTEK FIELD TESTING REPORT PROJECT NO.: 3447-$D3 DATE: 4-10-2019 NAME: Metcalfe HOURS: ------ CLIENT Vesta Pacific PROJECT Beachwalk at Roosevelt LOCATION Carlsbad --------- SUPT. Raul Ajinga CONTRACTOR V.i{,/?, /) t..l &-6J EQUWMENT None -------------------------------------- SUBJECT Foundations for Units listed below Location Elev. Moisture Dry %, Relative % Required Test No. Content% Density Compaction Compaction NO TESTS TAKEN COMMENTS: Observed soil conditions for following: Unit I, 2675 Roosevelt. CBRA 2018-0223: Unit 2, 2677 Roosevelt, CBRA 2018-0224 Unit 3, 2681 Roosevelt, CBRA 2018-0225: Unit 4, 2683 Roosevelt, CBRA 2018-0226 Unit 5, 2685 Roosevelt, CBRA 2018-0227: Unit 6, 2689 Roosevelt, CBRA 2018-0228 Unit 7, 2691 Roosevelt, CBRA 2018-0229: Unit 8, 2693 Roosevelt, CBRA 2018-0230 Unit 9, 2695 Roosevelt, CBRA 2018-0231: Unit I 0, 2697 Roosevelt, CBRA 2018-0232 Soil Type / Max Test Type Foundation excavations are in compliance with the geotechnical recommendations, care should be taken to remove any loose soil/slough in trenches before pouring. Soil should be moist when concrete is poured. GeoTe / -----------------------------/ Pass or Fail SUPERINTEDENT: By: . . . 'lt./z. COMPANY: Page ! INSPECTION SEJlVICES I 3406 Texas Street San Diego, CA, 92104 619-261-9022 desmond@Kingisi.com www.Kingisi.com SPECIAL INSPECTION DAILY REPORT Special Inspection Reports shall be prepared on a Daily Basis. All Non-Compliant conditions must be reported IMMEDIATELY to the Superintendent. Each Inspection Report shall be completed and signed by the Special Inspector conducting the Inspection / Testing. Project Name: Roosevelt Street Apartments Date: 7-29-20 Time Arrived: 9a.m. Hours: Project Location: 2675 Roosevelt St Carlsbad Time Departed: Contractor: Vesta Pacific Architect: MLA Sub-Contractor: Engineer: Gougl Inspection / Material Description Samples Ticket No#: AirTemo : !concrete Temo : @ Mins. lSlumo: 881126 74 I a5 so I 5• Approved Drawings: Included 8 Work Inspected: Inspection and observation of reinforcement and concrete placement at Building 1, Building 6 and Building 9 caissons along ==~'==~::::::.... __________ Roosevelt St. Contracior removed-all water-from-the footings-with a pum1>7No clearance or coverage lssueSc--Reinforcement-verifled secured property in place. Hanson mix design #3011100 was pumped into clean, debris free footings and consolidated with a vibrator -----------thenrnanuallyfinished. One set ol 5 cylinders was o6!liineafor estiiigan(lp aceariexflolneooitaing rgarage. ery c ean wo ~ Progress continue ... -... -.-------- ______ _.,eport emailed.to ragulnaga@vestapaclflcdevelopment.co .. ---------------- WORK: ~WAS WAS NOT INSPECTED I CC ANCE WITH THE REQUIREMENTS OF THE AP PRO DOCUMENTS. THE WORK INSPECTED: Signature of Special Inspector: MATERIAL SAMPLING:~ WAS NOT WA INSPECTED IN ACCORDANCE WITH HE REQUIREMENTS Print Name: Brandon Leonard CERTIFICATION #: sp114os OF THE APPROVED DOCUMENTS. LAB 10 ATTACHED, SAMPLES SCHEDULED FOR PICK-UP Signature of Superintendent: KINGI I nrsPEC a 10N mv.c:zs j SPECIAL INSPECTION DAILY REPORT 3406 Texas Street San Diego, CA, 92104 619-261-9022 desmond@Kingisi.com www.Kingisi.com Special Inspection Reports shall be prepared on a Daily Basis. All Non-Compliant conditions must be reported IMMEDIATELY to the Superintendent. Each Inspection Report shall be completed and signed by the Special Inspector conducting the Inspection/ Testing. Project Name: Roosevelt Apartments I Date: 09/26/19 Build inn Permit#: Build #2 / Unit #1: CBRA201 B-0223 Time Arrived: 1030am Proiect Location: 2675 Roosevelt ::;treet, t;arIsoaa, VA, 92008 Time Denarted: Contractor: Vesta Pacific Development Architect: Sub-Contractor: UPF Engineer: Inspection / Material Description Sheathing, Anchors, nailing, straps, clips Samoles Ticket No#: AirTemn: I Concrete Temn: @ Mins. lSlumn: I I Approved Drawings: SN• 1 , General notes Work Inspected: Inspection and Observation continues for Interior and Exterior Shearwalls. Verified stamped sheathing secured in place, All nails driven flush and staggered. Walls #2: 8d's@4/12, #3:3/12. #4 and #5: 2/12. All Header, Straps, Blocking, A35 Clips and Brackets per Shearwall Schedule. Holddown / anchors in place per plan schedule, engineers details. Hours: 4 Note : Partial interior inspection, All party walls: After plumbing, electrical, gas placement and insulation will be palace and wall closed, Fire stop @10'0". City inspector will verify prior to building being rapped. Report emailed to Super Raul WORK: f/~ ~---- INSPECTED l~:c.ceFfuANCE WITH THE RE~~EMENTS OF THE APPROVED DOCUMENTS. MATERIAL SAMPLING:-· INSPECTED IN ACCORDANCE WITH THE REQUIREMENTS OF THE APPROVED DOCUMENTS. LAB ID ATTACHED, SAMPLES SCHEDULED FOR PICK-UP i THE WORK INSPECTED: BiDiP Nor MffI Signature of Special Inspector: ~ Print Name: Desmond King CERTIFICATION#. SD #1169, ICC #8132156 Signature of Superintendent·¥; GeoTek, Inc. I 548 North Maple Street, Corona. California 92880 (95 I) 710-1160 Office (95 I) 710-1167 Fax www.geotekusa.com DAILY INSPECTION REPORT CLIENT: Vesta pacific development PROJECT NO: 3447-SD -------------------------------------PROJECT: Roosevelt ?t;/"75"' DATE: 04/10/19 PROJECT LOCATION: .c .. =:_R..;oo.c.s;..ce_ve..;;lt'--. C'-'•-~;;.;sbc.cad-'"-'C-'-A _________________________ _ CONTRACTOR: Verdugo construction PLANS BY: Gouvisengineer DATED: BUILDING PERMIT NO: c.BtZ 11 :iotB-02.23 APPROVED BY: CaMbad PC2018-0CJ19 DATED:----- 1YPE OF INSPECTION: Rebar SHEETS & DETAILS: -"=--------- LOCATION OF INSPECTION: Sea below -""'-'="'------------------------------- The following items were observed and / or tested: Inspection and observation continues for SOG / FTG reinforcement tor Building #2 Units 1 &2, building #3 units 3,4,5, building #1 units 8&9, Buliding #4 units 6,7, 10 and 11. Permits #CBRA2018-0223, CBRA2018-0224, CBRA2018-0225, CBRA2018-0226, CBRA2018-0227, CBRA2018-0230, CBRA2018-0231, CBRA2018·0228, CBRA2018-0229, CBRA2018-0232, CBRA2018-0233 Verified rebar is securely tied, with laps and clearance in place. #3@24" ocew, Cont (2)#4 TB, reinforcement for spread FTGs, All Pad FTGs verified, P3, P4, PS and P7 per Pad Schedule. FTGs are debris free, Anchors in placed for sill plates, strong wall and HDUs, Visqueen topped with 2" clean sand. General Notes, SN1, S01, exterior FTGs, foundation plans, Holddowns schedule 2500 psi Concrete scheduled for 04f11!19@0700am TBD. Raguinaga@vestapacificdevelopment.com PAGE ____ OF ____ _ E]Work observed during this inspection substantially complies to approved plans and specifications. ONot Complete. Work observed is still in progress and will require additional inspections. 4 Hours: ------------ SUPERVISOR: ~ Signature Desmond King S0#1169 / 8132156 Print Name GEOTECHNICAL I ENVIRONMENTAL I MATERIALS