Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2681 ROOSEVELT ST; ; CBRA2018-0225; Permit
Building Permit Finaled (city of Carlsbad Residential Associated Permit Print Date: 12/01/2020 Job Address: 2681 ROOSEVELT ST, CARLSBAD, CA 92008 Permit Type: BLDG-Associated Permit Residential Work Class: Parcel#: 2031013803 Track#: Valuation: $268,970.44 lot#: Occupancy Group: #of Dwelling Units: 1 Project#: Plan#: Bedrooms: 3 Construction Type: Condo CT140007 3 DEV04098 Bathrooms: 3.0 Orig. Plan Check #: PC2018-0019 Plan Check#: Project Title: BEACHWALK AT ROOSEVELT Permit No: CBRA2018-0225 Status: Applied: Issued: Finaled Close Out: Closed -Finaled 11/lS/2018 12/27/2018 Inspector: MColl Final Inspection: 12/01/2020 Description: BEACHWALK AT ROOSEVELT: BLDG 3 // UNIT 3 // PLAN B // 1,634 SF LIV// 433 SF GARAGE// 211 SF DECK Applicant: VESTA PROPERTIES GEOFF MCCOMIC 1818 1ST AVE SAN DIEGO, CA 92101-2662 (616) 481-3830 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Property Owner: M R CARLSBAD 11 LLC 1818 1ST AVE, # 100 SAN DIEGO, CA 92101 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFD SB1473 GREEN BUILDING STATE STANDARDS FEE SDCWA SYSTEM CAPACITY CHARGE 2" Displacement STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1 -Medium BLDG SW PPP PLAN REVIEW FEE TIER 1 -MEDIUM WATER METER FEE 2" Displacement (P) WATER SERVICE CONNECTION FEE 2" DISPLACEMENT (P) WATER TREATMENT CAPACITY CHARGE 2" Displacement Total Fees: $56,213.40 Total Payments To Date: Building Division $56,213.40 CoApplicant: VESTA PACIFIC DEVELOPMENT INC 1818 1ST AVE, # SUITE 100 SAN DIEGO, CA 92101-2662 (619) 481-3830 Balance Due: AMOUNT $1,225.95 $789.51 $66.00 $175.00 $92.00 $182.00 $9,413.97 $11.00 $21,416.00 $34.97 $246.00 $58.00 $588.00 $21,323.00 $592.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov Permit Type: BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner: M R CARLSBAD 11 LLC Work Class: Condo Issue Date: 12/27/2018 Subdivision: Status· Closed -Finaled Expiration Date: 08/10/2020 Address: 2681 ROOSEVELT ST IVR Number: 15492 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 12/19/2019 12/19/2019 BLDG·16 lnsulatlon 114318-2019 Passed Michael Collins Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/03/2020 01/03/2020 BLDG-17 Interior 116288-2020 Failed Michael Collins Reinspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Ne., 01/08/2020 01/08/2020 BLDG•17 Interior 115700-2020 Passed Michael Colllns Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 02/11/2020 02/11/2020 BLDG-18 Exterior 119064-2020 Passed Michael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-82 Drywall, 119154-2020 Passed Michael Collins Complete Exterior Lath, Gas Test, Hot Mop Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-17 Interior Lath-Drywall Yes BLDG-18 Exterior Lath and Yes Drywall BLDG-23 Gas-Test-Repairs Yes 08/04/2020 08/04/2020 BLDG•Electrlc Meter 134670-2020 Passed Michael Collins Complete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency EMR including, 2677 HM & 2681 HM, Yes emailed to SDGE 12/01/2020 12/01/2020 BLDG.final Inspection 145038-2020 Passed Chris Renfro Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG~Structural Final YP-s BLDG-Electrical Final Yes Tuesday, December 1, 2020 Page 3 of 3 r "-~fl~""'"" '' F_7?;,::,-"-:x,",~-:*''":::W -;;;;rec:.~ ~ '~~ _,,0 R I I . , £CTIOliHISTOfl¥L.WJ:~{'BRA2018-0225) Permit Type· BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner: M R CARLSBAD 11 LLC Work Class Condo Issue Date: 12/2712018 Subdivision: Status: Closed -Finaled Expiration Date: 08/10/2020 Address: 2681 ROOSEVELT ST !VR Number: 15492 CARLSBAD, CA 92008 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG·14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS Passed No No 06/25/2019 06125/2019 BLDG-14 095723-2019 Partial Pass Michael Collins Re1nspection Incomplete 08/30/2019 10/0712019 12/17/2019 Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS BLDG-Building Deficiency 3rd floor, floor sheathing and drag nailing BLDG-17 Interior Lath/Drywall CheckliSt Item 095585-2019 COMMENTS BLDG-Building Deficiency 08/30/2019 BLDG-15 Roof/ReRoof (Patio) Checklist Item 102695-2019 COMMENTS Cancelled Michael Colllns Partial Pass Michael Collins BLDG-Building Deficiency Sheathing/strap nailing only. 10/07/2019 BLDG-13 Shear Panels/HD (ok to wrap) Checklist Item 106777-2019 COMMENTS BLDG-Building Deficiency Minor pick up 12/17/2019 BLDG-27 Shower Pan/Tubs Checklist Item 114162-2019 COMMENTS BLDG-Building Deficiency BLDG-84 Rough Combo(14,24,34,44) 114123-2019 Checklist Item COMMENTS Passed Michael Collins Passed Michael Collins Passed Mlchael Collins BLDG-Building Deficiency Minor pick up, see contractor for list BLDG-14 Frame-Steel-Bolting-Welding (Decks) Passed Yes Reinspection Passed Nr, Reinspection Passed Yes Passed Y(;S Passed Ye:; Passed Yes Yes BLDG-24 Rough-Topout Ye:, BLDG~34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers Tuesday, December 1, 2020 Incomplete Incomplete Complete Complete Complete Page 2 of 3 Building Permit Inspection History Finaled (city of Carlsbad Permit Type: BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner: M R CARLSBAD 11 LLC Work Class Condo Issue Date: 12/27/2018 Subdivision: Status Closed -Finaled Expiration Date: 08/10/2020 Address: 2681 ROOSEVELT ST IVR Number: 15492 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 02/25/2019 02/25/2019 BLDG-21 084490-2019 Passed Michael Collins Complete U nd ergrou n d/U nderflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Waste only to POC Yes 04/10/2019 04/10/2019 BLDG-11 088473-2019 Failed Michael Collins Reinspection Incomplete Foundatlon/Ftg/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready, need electrical sub feed below N;, grade 04/15/2019 04115/2019 BLDG-11 088918-2019 Passed Michael Collins Complete Foundation/Ftg/Plers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Ufer ok, see CBRA2018-0223 for conduit Yes notes BLDG-Building Deficiency Not ready, need electrical sub feed below Nu grade 06/04/2019 06/04/2019 BLDG-14 093670-2019 Failed Michael Collins Reinspcction Incomplete Frame/Steel/Bolting/We lding (Decks) Checklist !tern COMMENTS Passed BLDG-Building Deficiency Not ready "Jn 06/05/2019 06/05/2019 BLDG-14 093820-2019 Passed Paul Burnette Complete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready Yes 06/17/2019 06/17/2019 BLDG-84 Rough 094836-2019 Partial Pass Paul Burnette Reinspection Incomplete Combo(14,24,34,44) Tuesday, December 1, 2020 Page 1 of 3 GeoTek, Inc. I 548 North Maple Street, Corona, California 92880 (951) 710-1160 Office (951) 710-1167 Fax www.geotekusa.com DAILY INSPECTION REPORT CLIENT: _ve:.:•:.:'•..:.P_•c_ifi_·c_d_ev_e_1o:..pm_e_n_t _________________ PROJECT NO: _344_7_-s_o ______ _ PROJECT: Roosevelt p, t,e,t DATE: 04/10/19 PROJECT LOCATION: _!.,,!!!!l!!:!R!'!oo~sev~e~lt.~C~•rl~s~b•~d!.!, C~A~---------,--------::-:-:=:::------ CONTRACTOR: Verdugo construction PLANS BY: Gouvts engineer DATED: _____ _ BUILDING PERMIT NO: e.,'3 MW! 0-0 22 £ APPROVED BY: Carlsbad PC201a-oo1s DATED: ____ _ TYPE OF INSPECTION: Rebar SHEETS & DETAILS: LOCATION OF INSPECTION: --~~be~low:!!_ _______________________ _ The following items were observed and / or tested: Inspection and observation continues for SOG / FTG reinforcement for Building #2 Units 1 &2, building lf3 units 3,4,5, building #1 units 8&9, Bullding #4 units6,7,10and 11. Pennits #CBRA2018-0223, CBRA2018-0224, CBRA2018-0225, CBRA2018-0226, CBRA2018-0227, CBRA2018-0230, CBRA2018-0231, CBRA2018-0228, CBRA2018-0229, CBRA2018-0232, CBRA2018-0233 Verified rebar is securely tied, wtth laps and dearance in place. #3@24n ocew, Cont (2}#4 TB, reinforcement for spread FTGs, All Pad FTGs verified, P3, P4, PS and P7 per Pad Schedule. FTGs are debris free, Anchors in placed for sill plates, strong waH and HDUs, Visqueen topped with 2'' clean sand. General Notes, SN1. S01, exterior FT Gs, foundation plans, Holddowns schedule 2500 psi Concrete scheduled for 04/11/19@0700am TBD. Raguinaga@vestapacificdevelopmentcom ----···-·------------------=-==--------PAGE ____ OF ____ _ ~ Work observed during this inspection substantially complies to approved plans and specifications. 4 Hours: ----------- SUPERVISOR: ~ D Not Complete. Work observed is still in progress and will require additional inspections. ~ Signature Desmond King S0#1169 / 8132156 Print Name GEOTECHNICAL I ENVIRONMENTAL I MATERIALS