Loading...
HomeMy WebLinkAbout2683 ROOSEVELT ST; ; CBRA2018-0226; PermitBuilding Permit Finaled (city of Carlsbad Residential Associated Permit Print Date: 12/01/2020 Permit No: CBRA2018-0226 Job Address: 2683 ROOSEVELT ST, CARl5BAD, CA 92008 Permit Type: BLDG-Associated Permit Residential Work Class: Parcel#: 2031013804 Track#: Valuation: $263,433.90 Lot#: Occupancy Group: #of Dwelling Units: 1 Project#: Plan#: Bedrooms: 3 Construction Type: Condo CT140007 4 DEV04098 Bathrooms: 3.0 Orig. Plan Check#: PC2018-0019 Plan Check#: Project Title: BEACHWALK AT ROOSEVELT Status: Applied: Issued: Finaled Close Out: Inspector: Final Inspection: Description: BEACHWALK AT ROOSEVELT: BLDG 3 // UNIT 4 // PLAN C // 1,599 SF LIV// 427 SF GARAGE// 211 SF DECK Applicant: VESTA PROPERTIES GEOFF MCCOMIC 1818 1ST AVE SAN DIEGO, CA 92101-2662 (616) 481-3830 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFD SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $11,766.72 Total Payments To Date: Building Division $11,766.72 Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov Closed -Finaled 11/15/2018 01/11/2019 MColl 12/01/2020 AMOUNT $1,208.20 $778.08 $66.00 $175.00 $92.00 $182.00 $9,220.19 $11.00 $34.25 $0.00 Page 1 of 1 Permit Type· BLDG-Associated Permit Residenti; Work Class Condo Application Date: issue Date: Status· Closed -Finaled Expiration Date: IVR Number Scheduled Actual Inspection Type Inspection No. Date Start Date Checklist Item COMMENTS BLDG-Building Deficiency BLDG-17 Interior Lath-Drywall BLDG-18 Exterior Lath and Drywall BLDG-23 Gas-Test-Repairs 08/04/2020 08/0412020 BLDG-Electric Meter 134669-2020 Release Checkhst Item COMMENTS 11/15/2018 01/11/2019 08/10/2020 15493 Inspection Status Passed BLOG-Building Deficiency EMR emailed to SDGE 12/0112020 12/0112020 BLDG-Final Inspection 145040-2020 Passed Checklist Item COMMENTS BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLOG-Electrical Final Tuesday, December 1, 2020 Owner: Subdivrs1orL Address-2683 ROOSEVELT ST CARLSBAD, CA 92008 Primary Inspector Reinspection Inspection Passed Yes Yes Yes Yes Michael Collins Complete Passed Yes Chris Renfro Complete Passed Y0s Yes Yes Yes Yes Page 4 of 4 Permit Type: BLDG-Associated Permit Residentii Application Date: 11/15/2018 Owner: Work Class Condo Issue Date: 01/11/2019 Subdivision: Status Closed -Finaled Expiration Date: 08/10/2020 Address: 2683 ROOSEVELT ST IVR Number: 15493 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 12/19/2019 12/19/2019 BLDG-16 lnsulatlon 114319-2019 Failed Michael Collins Reinspect/on Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready N;-, 12/20/2019 12/20/2019 BLDG-16 Insulation 114498-2019 Passed Michael Colllns Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Building Deficiency Not ready N 12/31/2019 12/31/2019 BLDG-17 Interior 115092-2019 Failed Michael Colllns Reinspect/on Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No superintendent or plans on site ~ J;' 01/02/2020 01/02/2020 BLDG-17 Interior 115186-2020 Failed Michael Collins Reinspcction Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No superintendent or plans on site No BLDG-Building Deficiency Screw spacing not per spec No 01/03/2020 01/03/2020 BLDG-17 Interior 115292-2020 Failed Michael Collins Reinspection Incomplete Lath/Drywall Checklist item COMMENTS Passed BLDG-Building Deficiency Screw spacing not per spec N, BLDG-Building Deficiency No superintendent or plans on site NcJ 01/08/2020 01/08/2020 BLDG-17 Interior 115806-2020 Passed Michael Collins Complete Lath/Drywall Checklist !tern COMMENTS Passed BLDG-Building Deficiency Screw spacing not per spec Ne BLDG-Building Deficiency Yes BLDG-Building Deficiency No superintendent or plans on site [\it, 02/11/2020 02/11/2020 BLOG-18 Exterior 119066-2020 Passed Mlchael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-82 Drywall, 119155-2020 Passed Michael Collins Complete Exterior Lath, Gas Test, Hot Mop Tuesday, December 1, 2020 Page 3 of 4 Permit Type: Work Class· Status Scheduled Date 06/25/2019 08130/2019 10/07/2019 12/17/2019 BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Condo Issue Date: Closed -Finaled Expiration Date: Actual Start Date IVR Number: Inspection Type Inspection No. Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS 01/11/2019 08/10/2020 15493 Inspection Status Owner: Subdivision: Address: 2683 ROOSEVELT ST CARLSBAD, CA 92008 Primary Inspector Reinspection Passed Nu No Inspection 0612512019 BLDG-14 095724-2019 Partial Pass Michael Collins Reinspection Incomplete Frame/Steel/Bolting/We !ding (Decks) Checklist Item COMMENTS BLDG-Building Deficiency 3rd floor, floor sheathing and drag nailing BLDG-17 Interior Lath/Drywall Checklist Item 095586-2019 COMMENTS BLOG-Building Deficiency 0813012019 BLDG-15 RooflReRoof (Patio) Checklist Item 102696-2019 COMMENTS Cancelled Michael Collins Partial Pass Michael Collins BLDG-Building Deficiency Sheathing/strap nailing only 10/07/2019 BLDG-13 Shear Panels/HD (ok to wrap) Checklist Item 106723-2019 COMMENTS BLOG-Building Deficiency Minor pick up 12/17/2019 BLOG-27 Shower Pan/Tubs Checklist Item 114161-2019 COMMENTS BLDG-Building Deficiency BLDG-84 Rough Combo(14,24,34,44) Checklist Item 114121-2019 COMMENTS Passed Michael Collins Passed Michael Collins Passed Michael Collins BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) Minor pick up, see contractor for list BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers Passed Yes Re inspection Passed f\.: Reinspuction Passed Yes Passed Yes Passed Yes Passed Yes Yes Yes Yes Yes Incomplete Incomplete Complete Complete Complete Tuesday, December 1, 2020 Page 2 of 4 Building Permit Inspection History Finaled Permit Type· BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner: Work Class; Condo Issue Date: 01/11/2019 Subdivision: (City of Carlsbad Status: Closed -Finaled Expiration Date: 08/10/2020 Address: 2683 ROOSEVELT ST !VR Number: 15493 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 02/2512019 02/25/2019 BLDG-21 084491-2019 Passed Michael Collins Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Waste not to POC Yes 04/10/2019 04/10/2019 BLDG-11 088474-2019 Failed Michael Colllns Re inspection Incomplete Foundatlon/Ftg/Piers (Rebar) Ctrncklist Item COMMENTS Passed BLDG-Building Deficiency Note ready, need electrical sub feed below f\L, grade 04/1512019 04/15/2019 BLDG-11 088915-2019 Passed Michael Collins Complete Foundation/Ftg/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Ufer ok, see CBRA2018-0223 for conduit Yes notes BLDG-Building Deficiency Note ready, need electrical sub feed below N,, grade 06/04/2019 06/04/2019 BLDG-14 093671-2019 Failed Michael Collins Reinspection Incomplete Frame/Steel/Boltlng!We !ding (Decks) Checklist ltern COMMENTS Passed BLDG-Building Deficiency Not ready N,, 06/06/2019 06/0512019 BLDG-14 093821-2019 Passed Paul Burnette Complete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready Ye:> 06/17/2019 05117/2019 BLDG-84 Rough 094837-2019 Partial Pass Paul Burnette Rcinspcction Incomplete Combo(14,24,34,44) Tuesday, December 1, 2020 Page 1 of 4 GeoTek, Inc. I 548 North Maple Street, Corona, California 92880 (951) 710-1160 Office (951) 710-1167 Fax www.geotekusa.com DAILY INSPECTION REPORT CLIENT: Vesta pacific development PROJECT NO: _344_7_-s_o ______ _ PROJECT: Roosevelt 6,fj ', DATE: 04110119 PROJECT LOCATION: ~.:!!.,,,_~R~oo~seve~tt!,c, C~•~~•~b~ad!,c, C~A!..------------------=:------- CONTRACTOR: Verdugo construction PLANS BY: Gouvtsenginoor DATED: _____ _ BUILDING PERMIT_N...:Oc..:c.J3--RJ'f-~9.~0~/~S~--0-2-2~1,--APPROVED BY: ca~bad PC201a-oo19 DATED: ____ _ TYPE OF INSPECTION: Rebar SHEETS & DETAILS: LOCATION OF INSPECTION: ~soe=bo:low~------------------------- The following items were observed and / or tested: Inspection and observation continues for SOG I FTG reinforcemenl for Building 12 Units 1 &2, building #3 units 3,4,5, building #1 units 8&9, Bulidlng #4 1urtils6,7,10and 11. -Its #CBRA2018-0223, CBRA2018-0224, CBRA2018-0225, CBRA2018-0226, CBRA2018-0227, CBRA2018-0230, CBRA2018-0231, CIIIIA2018-0228, CBRA2018-0229, CBRA2018-0232, CBRA2018-0233 Verified rebar is securely tied, with laps and clearance in place. #3@24" ocew, Cont (2)#4 TB, reinforcement for spread FT Gs, All Pad FTGs verified, P3, P4, PS and P7 per Pad Schedu1e. FTGs are debris free, Anchors in placed for sill plates, strong wall and HDUs, Visqueen topped with 2" clean sand. General Notes, SN1, S01, exterior FTGs, foundation plans, Holddowns schedule 2500 psi ConOl'ote scheduled for 04/11tl9@070Qam TBO. Raguinaga@vestapacificdevelopmentcom PAGE ___ _ OF ------ ~Work observed during this inspection substantially complies to approved plans and specifications. ONot Complete. Work observed is still in progress and will require additional inspections. ~ Hours: _• __________ _ Signature SUPERVISOR: ~-,, Desmond King S0#1169 /6132156 Print Name GEOTECHNICAL I ENVIRONMENTAL I MATERIALS ICINGI I DISP&:C I 1(>118EJI.VICE8 ! SPECIAL INSPECTION DAILY REPORT 3406 Texas Street San Diego, CA, 92104 619-261-9022 desmond@Kingisi.com www.Kingisi.com Special Inspection Reports shall be prepared on a Daily Basis. All Non-Compliant conditions must be reported IMMEDIATELY to the Superintendent. Each Inspection Report shall be completed and signed by the Special Inspector conducting the Inspection/ Testing. Project Name: Roosevelt Apartments I Date: 09/26/19 Buildina Permit#: Build #3. / Unit #4: CBRA2018-0226 Time Arrived: 1030am Proiect Location: 2675 Roosevelt Street, Carlsbad, CA, 92008 Time Denarted: Contractor: Vesta Pacific Development Architect: Sub-Contractor: UPF Engineer: Inspection / Material Description Sheathina, Anchors, nailina, straps, clips Samcles Ticket No#: AirTemo: !concrete Tern"': @ Mins. lSlumo: I I Approyed Drawings: SN-1 , General notes Work Inspected: Inspection and Observation continues for Interior and Exterior Shearwalls. Verified stamped sheathing secured in place, All nails driven flush and staggered. Walls #2: 8d's@4/12, #3:3/12. #4 and #5: 2/12. All Header, Straps, Blocking, A35 Clips and Brackets per Shearwall Schedule. Holddown / anchors in place per plan schedule, engineers details. Hours: 4 Note : Partial interior inspection, All party walls: After plumbing, electrical, gas placement and insulation will be palace and wall closed, Fire stop @10'0". City inspector will verify prior to building being rapped. Report emailed to Super Raul WORK: ~ ~--- INSPECTED l~NCE WITH THE RE;;REMENTS OF THE APPROVED DOCUMENTS. MATERIAL SAMPLING:-~ INSPECTED IN ACCORDANCE WITH T~EQ~S V OF THE APPROVED DOCUMENTS. LAB ID ATTACHED, SAMPLES SCHEDULED FOR PICK-UP THE WORK INSPECTED: e □IP NOJ Mffl--···-· Signature of Special Inspector: ~ Print Name: Desmond King CERTIFICATION#: SD #1169, ICC #8132156 Signature of Superintendent ¥;