HomeMy WebLinkAbout2691 ROOSEVELT ST; ; CBRA2018-0229; PermitBuilding Permit Finaled
(City of
Carlsbad
Residential Associated Permit
Print Date: 12/02/2020 Permit No: CBRA2018-0229
Job Address: 2691 ROOSEVELT ST, CARLSBAD, CA 92008
Permit Type: BLDG-Associated Permit Residential Work Class:
Parcel#: 2031013807 Track#:
Valuation: $267,769.30 Lot#:
Occupancy Group:
#of Dwelling Units: 1
Project#:
Plan#:
Bedrooms: 3 Construction Type:
Condo
CT140007
7
DEV04098
Bathrooms: 3.0 Orig. Plan Check#: PC2018-0019
Plan Check#:
Project Title: BEACHWALK AT ROOSEVELT
Status:
Applied:
Issued:
Finaled Close Out:
Inspector:
Final Inspection:
Description: BEACHWALK AT ROOSEVELT: BLDG 4 // UNIT 7 //PLANA// 1,623 SF LIV// 434 SF GARAGE// 232 SF DECK
Applicant:
VESTA PROPERTIES
GEOFF MCCOMIC
1818 1ST AVE
SAN DIEGO, CA 92101-2662
(616) 481-3830
FEE
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES -outside CFD
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
Total Fees: $11,942.37 Total Payments To Date:
Building Division
$11,942.37 Balance Due:
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
Closed -Finaled
11/15/2018
01/11/2019
MColl
12/02/2020
AMOUNT
$1,222.40
$787.23
$66.00
$175.00
$92.00
$182.00
$9,371.93
$11.00
$34.81
$0.00
Page 1 of 1
Permit Type· BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner:
Work Class. Condo Issue Date: 01/11/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 08/10/2020 Address: 2691 ROOSEVELT ST
IVR Number: 15496 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
•--''" ~·-•---···
BLDG-82 Drywall, 119303-2020 Passed Michael Collins Complete
Exterior Lath, Gas Test,
Hot Mop
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-17 Interior Lath-Drywall Y(;s
BLDG-18 Exterior Lath and YBS
Drywall
BLDG-23 Gas-Test-Repairs Yes
02/24/2020 02/24/2020 BLDG-27 Shower 120095-2020 Failed Michael Collins Re inspection Incomplete
Pan/Tubs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
08/06/2020 08106/2020 BLOG-Electric Meter 134944-2020 Passed Paul Burnette Complete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Ye~,
------· 12/02/2020 12/02/2020 BLOG-Final Inspection 145172-2020 Passed Chris Renfro Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
Wednesday, December 2, 2020 Page 3 of 3
Permit Type: BLDG-Associated Permit Residenti, Application Date: 11/15/2018 Owner:
Work C!ass Condo Issue Date· 01/11/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 08/10/2020 Address: 2691 ROOSEVELT ST
IVR Number: 15496 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
~ "·"''~~·-·-·~·-·
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 2nd floor, floor sheathing/drag nailing Yes
BLDG-Building Deficiency Not ready, no super on site Nr,,
BLDG-Building Deficiency 3rd floor, floor sheathing and drag nailing Yes
09/0412019 09/04/2019 BLDG-15 Roof/ReRoof 102945-2019 Partial Pass Chris Renfro Reinspection Incomplete
(Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency See back of card. Yes
10/15/2019 10/15/2019 BLDG-13 Shear 107 435-2019 Passed Paul York Complete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/06/2020 01/0612020 BLDG-14 115367-2020 Failed Michael Collins Roinspection Incomplete
Frame/Steel/Boltlng/We
!ding (Decks)
Checklist ltern COMMENTS Passed
BLDG-Building Deficiency 2nd floor, floor sheathing/drag nailing Yes
BLDG-Building Deficiency 3rd floor, floor sheathing and drag nailing Yes
BLDG-Building Deficiency Not ready, no super on site No
01/08/2020 01/08/2020 BLDG-14 115703-2020 Partial Pass Mlchael Colllns Reinspection Incomplete
Frame/Steel/Bolting/We
!ding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready, no super on site Nn
BLDG-Building Deficiency 2nd floor, floor sheathing/drag nailing Yes
BLDG-Building Deficiency 3rd floor, floor sheathing and drag nailing Yes
01/13/2020 01/13/2020 BLDG-16 Insulation 116070-2020 Passed Michael Collins Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/27/2020 01/27/2020 BLDG-17 Interior 117557-2020 Passed Luke Storno Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Drywall only Nu
02/12/2020 02/12/2020 BLDG-27 Shower 119226-2020 Passed Michael Collins Complete
Pan/Tubs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Wednesday, December 2, 2020 Page 2 of 3
Building Permit Inspection History Finaled
Permit Type: BLDG-Associated Permit Residenti;
Work Class Condo
Application Date: 11/15/2018 Owner:
Subdivision·
( City of
Carlsbad
Status. Closed -Finaled
Issue Date: 01/11/2019
Expiration Date: 08/10/2020
IVR Number: 15496
Address: 2691 ROOSEVELT ST
CARLSBAD, CA 92008
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No, Inspection Primary Inspector
Status -----·---------~-~.---
02/28/2019 02/26/2019 BLDG-21 084640-2019 Passed Michael Collins
Underground/LI nderflo
or Plumbing
BLDG-Building Deficiency
COMMENTS
Waste to POC only
04/11/2019 04/11/2019 BLDG-11 088666-2019 Failed Michael Collins
04/15/2019
08/07/2019
06/27/2019
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item
BLDG-Building Deficiency
COMMENTS
Not ready, complete underground electrical
04/15/2019 BLDG-11
Foundation/Ftg/Plers
(Rebar)
088922-2019 Passed Michael Colllns
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
Ufer ok, see CBRA2018-0223 for conduit
notes
Not ready, complete underground electrical
06/07/2019 BLDG-14 094153-2019 Partial Pass Michael Collins
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item
BLDG-Building Deficiency
COMMENTS
2nd floor, floor sheathing/drag nailing
06/27/2019 BLDG-14 095957-2019 Failed Michael Collins
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
Not ready, no super on site
2nd floor, floor sheathing/drag nailing
08/28/2019 06/28/2019 BLDG-14 096112-2019 Failed Michael Collins
Frame/Steel/Boltlng!We
ldlng (Decks)
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
2nd floor, floor sheathing/drag nailing
Not ready, no super on site
07/02/2019 07/02/2019 BLDG-14 096492-2019 Partial Pass Michael Collins
Frame/Steel/Bolting/We
ldlng (Decks)
Wednesday, December 2, 2020
Reinspection Inspection
Complete
Passed
'res
Rcinspection Incomplete
Passed
No
Complete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
No
Yes
Roinspection lncomplote
Passed
Yes
f\i,;
Reinspection Incomplete
Page 1 of 3
KINGI
! IIISPECTION SElt.YJCES !
SPECIAL INSPECTION DAILY REPORT
3406 Texas Street
San Diego, CA, 92104
619-261-9022
desmond@Kingisi.com
www.Kingisi.com
Special Inspection Reports shall be prepared on a Daily Basis. All Non-Compliant conditions must be reported
IMMEDIATELY to the Superintendent. Each Inspection Report shall be completed and signed by the Special
Inspector conducting the Inspection/ Testing.
Project Name: Roosevelt Apartments / Date: 09/26/19
Buildina Permit#: Build #4 / Unit #7: CBRA2018-0229 Time Arrived: 1030am
Proiect Location: .::1;115 Roosevet .:itreet, 1...anscaa, CA, 92000 Time Denarted:
Contractor: Vesta Pacific Development Architect:
Sub-Contractor: UPF Engineer:
Inspection / Material Description Sheathina, Anchors, nailina, straos, clips
Samoles
Ticket No#: AirTemo: [Concrete Temo: @ Mins. lSlumo :
I I
Approved Drawings; SN-1, General notes
Work Inspected:
Inspection and Observation continues for Interior and Exterior Shearwalls.
Verified stamped sheathing secured in place, All nails driven flush and staggered.
Walls #2: 8d's@4/12, #3:3/12. #4 and #5: 2/12.
All Header, Straps, Blocking, A35 Clips and Brackets per Shearwall Schedule.
Holddown I anchors in place per plan schedule,-engineers details.
Hours: 4
Note: Partial interior inspection, All party walls: After plumbing, electrical, gas placement and insulation will be
palace and wall closed, Fire stop @10'0".
City inspector will verify prior to building being rapped.
Report emailed to Super Raul
WORK: ~ ~
INSPECTED l~CCei<o:ANCE WITH THE REQUIREMENTS
OF THE APPROVED DOCUMENTS.
MATERIAL SAMPJJNG:--~)
INSPECTED IN ACCORDANCE WITH .;:;REQ~~~S C/
OF THE APPROVED DOCUMENTS.
LAB ID ATTACHED, SAMPLES SCHEDULED FOR PICK-UP
THE WORK INSPECTED: Bprp NOTMFFI
Signature of Special Inspector: ~
Print Name: Desmond King
CERTIFICATION#: SD #1169, ICC #8132156
Signature of Supenntendent: ¥;
GeoTek, Inc.
1548 North Maple Street, Corona. California 92880
(951) 710-1160 Office (951) 710-1167 Fax www.geotekusa.com
DAILY INSPECTION REPORT
CLIENT: _~_e_•_••.;_P_•C1-·fi_·c_de_v_e1opm_.;___en_1 _________________ PROJECT NO: _344_7_.s_o ______ _
PROJECT: Roosevelt 9,(,9' DATE: 04/10/19
PROJECT LOCATION: .!_,!'!l!!..!:R~oo~seve~!!:.lt,.!:'.C~•rl~•ba~d,:_!:C~Ac_ ______________________ _
DATED: ____ _ CONTRACTOR:V _e.;_rd_u.,:go_con_stru __ cti_·on _____ .....,,__ PLANS BY: Gouvis engineer
BUILDING PERMIT NO:CBt.ft 2016 -O '22. 'J APPROVED BY: Carlsbad PC2018-0019 DATED: ____ _
TYPE OF INSPECTION: .:.A.:,:eba=.r _______ SHEETS & DETAILS:
LOCATION OF INSPECTION: ...:See2!!.~be~low!!_ _______________________ _
The following items were observed and / or tested:
Inspection and observation continues for SOG / FTG reinforcement for Building 112 Units 1 &2, building #3 units 3,4,5, building #1 unhs 8&9, Bulidlng #4
unlts6,7,10and 11.
Permits #CBAA2018-0223, CBRA2018-0224, CBRA2018-0225, CBAA2018-0226, CBRA2018·0227, CBAA2018-0230, CBRA2018-0231,
CBAA201B-0228, CBRA2018-0229, CBRA2018-0232, CBRA2018-0233
Verified rebar Is securely tied, with laps and clearance in place. #3@24" ocew, Cont (2)#4 TB, reinforcement for spread FTGs,
All Pad FTGs verified, P3, P4, PS and P7 per Pad Schedule.
FTGs are debris free, Anchors in placed for sill plates, strong wall and HDUs,
Visqueen topped wtth 2" ciean sand.
General Notes, SN1, S01, exterior FTGs, foundation plans, Holddowns schedule
2500 psi Conaete scheduled for 04/11/19@0700am TBD.
Raguinaga@vestapacfficdevelopment.com
El Work observed during this inspection substantially
complies to approved plans and specifications.
4 Hours: ----------
SUPERVISOR: ~"?
PAGE OF -----------
□ Not Complete. Work observed is still in progress and
will require additional inspections.
~
Signature
Desmond King S0#1169 / 8132156
Print Name
GEOTECHNICAL I ENVIRONMENTAL I MATERIALS
EAGLE AIR
616 W. 3"0 AVE.
ESCONDIDO, CA. 92025
PHONE: ?6D·4BD•0599
F'AX: 760•480•0698
January 2, 2020
Re: Vesta Pacific Development, Beachwalk @ Roosevelt
To whom it may concern,
The Bath fan installed at the BWR baths 2 and 3 with a 4" Connection
will meet the required cfm for those rooms. The cfm for the size of the
secondary baths calculates out to be 50 CFM. The 4" fan with the 5" duct
will exceed the minimum by 30 cfm.
Please see ASHRAE Standard 62.2 Table below.
ASHRAE Standard 62 2 Table 71
T-7.1_ ..... _. -OuctT ...... Flea Duct Smooth Duct
Fan Rating
elm tD 0.25 so 80 100 125 so 80 100
in.w.1.
Maximum Allowable Duct Lenoth (ft)
Diameter, (In) Flex Duct Smooth Duct
3 X X X X 5 X X
4 70 3 X X 105 35 s
5 NL 70 35 20 NL 135 85
6 NL NL 125 95 NL NL NL
7 and abmie NL NL NL NL NL NL NL
This table assumes no elbows. Dedud: 15 ft of allowable duct lanadh for each tum elbow or fittin•.
NL"' no limit on duct IHloth of this size
X ... not allowed am1 lenoth of duct of this size with assumed tums. elbows. flttlnos will exceed t~ rated IH'M.tt.ure dron
Sincerely,
Gary Boberg
President
• ,-..;:.::,:;Ml~.-:~'> . .,1,"t-
1\\.l~(Jf-:,
,~tCORD COPY
CALIF"OANIA STATE CONTRACTORS LICENSE NUMBER 958703
125
X
X
55
145
NL
December 18, 2019
R. Geoffrey McComic
Vesta Pacific Development
1818 First Ave, Suite I 00
San Diego, CA 92101
Re: Beachwalk at Roosevelt
Stair Head-Out
GECG Job No. 64139-505
Dear Mr. McComic,
A TRUSTED PARTNf..R IN
INNOVATION. QUA! ITY & srnv,cE
Pursuant to your request regarding the above captioned project, we submit the following:
It is structurally acceptable to rip I 3/4"xl4" LSL to I 3/4"x9" LSL at first floor right above the entry
at Building 3, unit 4 and Building 5, unit 13 for head height clearance.
We have reviewed the calculations for the beam and all the allowable stresses are still met.
If you have any questions please do not hesitate to contact this office.
Sincerely,
GOUVIS ENGINEERING CONSULTING GROUP, INC.
,-~~/
Huan Nguyen, P.E.
Executive Vice President, Partner
949.752.1612
15 Studebaker
Irvine, CA
92618
www.gouvisgroup.com Palm Springs, CA Pleasanton, CA Ho Chi Minh City, Vietnam ■ '