HomeMy WebLinkAbout2877 SEGOVIA WAY; ; CB122715; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
01-17-2013 Cogeneration Permit Permit No:CB122715
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
Applicant:
2877 SEGOVIA WY CBAD
COGEN Sub Type: PHOTO
Lot#: 0
Constuction Type: 5B
Reference #:
2552804000
$6,800.00
CRAVETS RESIDENCE
17 PANEL ROOF MOUNTED PV SYSTEM
Owner:
Status: ISSUED
Applied: 12/19/2012
Entered By: MOP
Plan Approved: 01/17/2013
Issued: 01/17/2013
Inspect Area:
Plan Check #:
AMERICAN SOLAR DIRECT
STE 240
CRAVETS FAMILY TRUST 02-17-11
2400 BROADWAY
SANTA MONICA CA 90404
424 217-6700
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Green Bldg Stands (SB1473) Fee
$97.47
$0.00
$68.23
$39.27
$0.00
$1.00
$1.00
2877 SEGOVIA WAY
CARLSBAD CA 92009
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Additional Fees
TOTAL PERMIT FEES
Total Fees: $206.97 Total Payments To Date: $206.97 Balance Due:
Inspector:
FINAL APPROVAL
Date: 2 -2b · /-~ Clearance:
$0.00
$0.00
$0.00
$0.00
$206.97
$0.00
NOTICE: Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the Clty Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
x i n f w i h r i I I E i ii r h" whi h h limi
~~·.·· Building Permit Application Plan Check No. t'L·
fu5c-oi> ,:, $•·)/ 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value ~ CITY OF 760-602-2717 / 2718/ 2719
CARLSBAD Fax: 7 60-602-8558 Plan Ck. Deposit .
www.c~r!sbedca,gov Date 11 __, I ,c;./.rJswPP
JOB ADDRESS 1fo7, S<..(\OV;"'-. w lk.'-/
SUITE#/SPACE#/UNIT# l"Ni'J5 -·2..so -Yoct) -
CT/PROJECT# ! LOT# ~ ! PHASE# I# o, UNITS I# BEDROOMS . # BATHROOMS I TENA,~I BUSINESS NAiv1E ICONS1R. TYPE I DCC.GROUP
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
(jc.ooC-""°"""~\_ rl,,,o+o\l c,\..\,...iL /+rv-A.'--J . L-1. I(, /4-r. 17 rV\6J,......lu
' a...--,}. \, M 1c...rv ~ i"'vc.r ~ L
EXISTING USE I PROPOSED USE I GARAGE (SF) PATIOS (SF) I DECKS {SF) (REPLACE 'AIR CONDITIONING I FIRE SPRINKLERS
YES □# __ NO □ YES □ NOD YES O NOD
APPLICANT NAM£ (Primary Contact) R 0-V\ cl,-, M .... "(do-.... APPLICANT NAME (Secondary Contact)
ADDRESS ~3Y 0 , 'F &,,...,;.,...., So-.,.,-k. ~ #E= ADDRESS
CITY 5,,__..., Di=o sci\ ZIP CITY STATE ZIP
92.12...1
PHONE '310-,tb-S'.31"'\ l'AX PHONE l'AX
E1v1AIL rV"' .... 'fU"-..<l) t...llV)e...--i'UU'\ Sbl11--..-d.,r~i-EMAIL
~ROPERTY OWN~ NA'rf I fir,,..,'-~ CONTRACTOR BUS. NAME
AMev-i" c.o.,"' Sol.._,,,-Di~ ,,_ ' .
ADDRESS j,, O
0 17 5'~bV'~ H/1---'-J
ADDRESS '2-LJDD 13 ro ,._J_,.,., "-'-/ Av-e_ It .:Z.40 ,
CITY u.v--\\1:,~ STATE ' (AA tf '2-0o ~p CITY 45 1" STATE a-.v1 tJ.... Mo V' i c:.,.._ , C..A ZIP
"'\OL./ O'-/
PHONE ,{,o-"IL\1-80,l-f l'AX PHONE ) ( l.j1.L/ "2.11.-\ -(;-706 l'AX
E1v1AIL fo,All lo . I d ' i ,-... Cll "'-""'ev-1 C:."-"' _<;o t,.r ,re<...-\--. C,O ,,,..,,
ARCH/DESIGNER NAME &AD~SS\ IN, o .. "'"'v ,.. l'l W"C.-I ''q'~I, ;<, '\ STATELIC.# Pi L-1 I Ob 'I f'k-10 I L-l.'.i1"' LI12:1>4 '54 'L
(Sec. 7031.5 Bus1ness {Ind Profes~ions d'ode: Any City or County which requires a permit to_c!=mstruct alter, Improve, ~emollsh or re air an structure, Rrior t9 its issuance, also req\Jlres the appllcant for such permit to fi!e a signed statement ttiat he Is licensed pursuant to the prov1s1ons of the Contractor's License Law {Cgaptert, commend mg with Section 7000 of Dlv1slon 3 of the Business and Professions Code} or that he is exemP.t therefrom, and the basis for the alleged exemption. Any violation of Section 1031.5 by any appl!cant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500)).
~;~~ · .. :ITJfm,~itlmf~ === ==='" -·~~~:
mpensatron Declaration: / hereby affinn under pena/1',' of perjury one of the following declarations:
ave and will maintain a certificate of consent to self•lnsure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued.
I have and will maintain workers' compensation, as required by l3ectip11 370Qof the Labor Code, for the performance of the work for which this permit 15,issued. My workers' compensation insur nee arrier and policy
number are: Insurance Co. ~""'er'---S' lnAµ.S-½v-\..f Policy No. W LO) J '] J Q 7 0 ~ Expiration Date _ __,_.{)4----'-+-'--''---
This sei:;lion need not be completed if the permit is for one hundred dollars ($100) or less. D Certificate of Exemption: I certify that ln the performance of the work for which this permit is Issued, I shall not employ any person in ar1y manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Fallureto secure workers' c ensation coverage is unlawful, and shall sub/ectan employer to criminal penallles and clvll fmes upto one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages a r lded for In Section 3706 of the , nterest and attorney's fees./
A5 CONTRACTOR SIGNATURE '-_,,,-~GENT DATE j 2--i'I
~·
I hereby affinn that I am exempt from Contractor's Ucense Law for the fol/owing reason:
□ I, as owner of the property or my employees with wages as their sole compensation, will do the work ar1d the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contracto~s
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own empbyees, provided that such ill"flrovements are not intended or offered for
sale. If, however, the building or improvement Is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or Improve for the purpose of sale).
□ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contracto~s License Law).
□ 1 am exempt under Section ____ ~u,siness and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property Improvement □ Yes □ No
2. l (have I have not) signed an application for a buflding permit for the proposed work..
3. I have contracted with the following person (firm) to provide the proposed construction 0nclude name address/ phone I contractors' license number):
4, I plan to provide portions of the work, i:ut I have tired the following person to coordinate, supervise and provide the major work (include name/ address I phone/ contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work):
Ji$ PROPERTY OWNER SIGNATURE □AGENT DATE
I
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? □ Yes □ No
Is the applicant or future building occupant required to obtain a permit from the air pollution control districl or air quality management district? □ Yes □ No
Is the facllity to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
:'i"'lli'<iz*!;j:'.;ii••J~~~',•',it'i"""',tf\'J!'fil'!iti¼t\.i:i:r1,l~'1>il!ii,J1,•;•,-;,;,•i\~illii'"V'~,:,f'(,1£Z''l!':,1<,,;:~W,i~;;,t,,i;.',\\U•;,:;,-<llll'.,~n~"1,1tf,;,[-,, ·":,_i?,-;,"!,,.th-11oi!1t+J~~\o1.ft~w }i:,~~-,~•,.,,,-0'1-:,.0 .. ~.-WJJ/fJ'.Ji(.!1.~'M14,m.t~jl',.,.,~pi,t~:H· i!JY'7~~Jj;ti~ .. ~~ ... -?;:!,,.,'.'1.,~,-v4:-.. ~~ ... ~.r,h,.""~~~ -:11v~•"ii$ltf~J:~1~{-'.
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code) ..
Lender's Name Lender's Address
;~ '1!/lt~'~i/ft~~,i'1fsjfi \li\li'£il''ifiif i'~'~Jj•~~li(fi1t:!fl~fi,\',\Y,:.;t~,_:r,;, ,t.~}'.>~t'!,la,,.;;,._1 .• \,k 4. ;J., •. d< '•rn'fl.'.-,1~ ,i,. ,t~ ~,-~('.11,r )"~,, fflr~Ji~~-,..i(jjj-~~
I certify that I have read the applicatlon and state that the abmie infonnation Is conectand that the lnfom,atlon on the plans Is accurate. I agree to complywm, a 11 City ordinances and State law.; relating b) bullding construction.
I hereby authorize representatjve of the City of Carlsbad to enterUJX)!l the above mentioned property for i1spection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CI\R!...SMD
A(AINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN Afr/WAY ACCRUE AGAINST SAID CflY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: AA OSHA permit is required for excavations over 50' deep and demolition or construction of structures over 3 stories in height.
EXPIR.A.TION: Every pennlt issued by the Eru1lding Offici nder tte provisbns of this C.ooe shall expire by limitation and berome null and void IT the building or'AOfk authorized by sudl pennit is not commenced 'Mlhin
180 days from the dale of sudl pennitor IT the build· Q authorized by such pennit is suspended or abandoned at anytime after the work is commenced for a period of 180 days (Section 100.4.4 Unifonn Bu1ldfrlg Code).
~ APPLICANT'S SIGNATURE DATE
STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final. inspection.
CERTIFICATE OF OCCUPANCY !Commercial Projects 0 n I y l
Fax (760) 602--8560, Email www.bui1dinq@car1sbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
CO#: (Office Use Only)
CONTACT NAME OCCUPANT NAME
ADDRESS BUILDING ADDRESS
CITY STATE ZIP CITY STATE ZIP
Carlsbad CA
PHONE I FAX
EMAIL OCCUPANT'S BUS. UC. No.
DELIVERY OPTIONS
D PICKUP: □ CONTACT (Listed above) o OCCUPANT (Listed above)
□ CONTRACTOR {On pg. 1)
D ASSOCIATED CB# □ MAIL TO: a CONTACT (Listed above) o OCCUPANT (Listed above)
□ CONTRACTOR (On pg. 1) □ NO CHANGE IN USE/ NO CONSTRUCTION
□.MAIL/ FAX TO OTHER: o CHANGE OF USE/ NO CONSTRUCTION
A$ APPLICANT'S SIGNATURE OATE
Inspection List
Permit#: CB122715 Type: COGEN PHOTO CRAVETS RESIDENCE
17 PANEL ROOF MOUNTED PV SYSTEM
Date lnsp...:tion Item Inspector Act Comments
02/25/2013 35 Photo Voltaic (PV) RI
02/25/2013 35 Photo Voltaic (PV) PB AP
02/25/2013 39 Final Electrical RI
02/25/2013 39 Final Electrical PB AP
Tuesday, February 26, 2013 Page 1 of 1
DATE: January 15, 2013
JURISDICTION: Carlsbad
PLAN CHECK NO.: 12-2715
EsGil Corporation
In a!artnersfiip with government for '1JuiUino Safety
SET: II
PROJECT ADDRESS: 2877 Segovia Way
□ APPLICANT
□ JURIS.
□ PLAN REVIEWER
□ FILE
PROJECT NAME: Carvets 17 Microinverter Solar Photovoltaic System
[8J The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
[8J Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Randy Mayeda Telephone#: 424 214-6700
Date contacted: (by: ) Fax #: 424 214-6750
Mail Telephone Fax In Person
0 REMARKS:
By: Eric Jensen
EsGil Corporation
□GA □EJ □PC
E-mail: rmayeda@americansolardirect.com
Enclosures:
01/10
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
EsGil Corporation
In <Partnersnip witn fiovemment for !Bui(aing Safety
DATE: December 31, 20212
JURISDICTION: Carlsbad
PLAN CHECK NO.: 12-2715
PROJECT ADDRESS: 2877 Segovia Way
SET: I
□ APPLICANT _/d JURIS.
□ PLAN REVIEWER
□ FILE
PROJECT NAME: Carvets 17 Microinverter Solar Photovoltaic System
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
[8J The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
D Esgil Corporation staff did not advise the applicant that the plan check has been completed.
[8J Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Randy Mayeda Telephone#: 424 214-6700
Date contacted: (by: ) Fax #: 424 214-6750
Mail Telephone Fax In Person
0 REMARKS:
By: Eric Jensen
EsGil Corporation
□ GA □ EJ □ PC
E-mail: rmayeda@americansolardirect.com
Enclosures:
12/20
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad 12-2715
December 31, 20212
GENERAL PLAN CORRECTION LIST
JURISDICTION: Carlsbad
PROJECT ADDRESS: 2877 Segovia Way
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 12/20
REVIEWED BY: Eric Jensen
FOREWORD (PLEASE READ):
PLAN CHECK NO.: 12-2715
DATE REVIEW COMPLETED:
December 31, 20212
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and disabled access. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. The approval of
the plans does not permit the violation of any state, county or city law.
• Please make all corrections and submit two new complete sets of prints to:
ESGIL CORPORATION.
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
D Yes D No
Carlsbad 12-2715
December 31, 20212
ELECTRICAL and ENERGY COMMENTS
PLAN REVIEWER: Eric Jensen
ELECTRICAL (2010 CALIFORNIA ELECTRICAL CODE)
1. Number 8 grounding electrode conductor to all inverters. Your single line specifies No.
10. Please correct.
2. Provide voltage drop (gain) calculations for the 17 microinverter branch circuit. Enphase
has a technical brief concerning this design on their website: Engage Cables and AC
Line Voltage Drop. Note: Design interconnection of inverters reduces this issue. Your
single line has all of the inverters connected one after another.
Note: If you have any questions regarding this Electrical and Energy plan review list please
contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a
copy) where the corrected items have been addressed on the plans.
Carlsbad 12-2715
December 31, 20212
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Eric Jensen
PLAN CHECK NO.: 12-2715
DATE: December 31, 20212
BUILDING ADDRESS: 2877 Segovia Way
BUILDING OCCUPANCY:
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
--------
Bldg. Permit Fee by Ordinance ...
Plan Ch~c-kf-ee by Ordina_nc_e __ --~
Type of Review· □ Complete Review
D Repetitive Fee
~] Repeats
* Based on hourly rate
Comments: 1 hour plan review.
□ Other
8 Hourly
EsGil Fee
TYPE OF CONSTRUCTION:
Reg. VALUE
Mod.
□ Structural Only
,__ ___ 1_,I Hr. @ •
($)
Sheet 1 of 1
macvalue.doc +