HomeMy WebLinkAbout1037 SEAHORSE CT; ; CBR2019-0062; PermitResidential Permit
Print Date: 01/07/2020
Job Address:
Permit Type:
1037 Seahorse Ct
BLDG-Residential
2145305100
$31,893.00
Work Class: Addition
Parcel No: Lot#:
Valuation: Reference #:
Occupancy Group: Construction Type:
# Dwelling Units: Bathrooms:
Bedrooms: Orig. Plan Check#:
Plan Check#:
Project Title:
Description: BARRE: 147 SF ADDITION AND 150 SF REMODEL
Applicant: Owner:
BA WORTHING INC
BROOKS WORTHING
COOWNER BARRE OLE JR AND ALYSHA L
1037 Seahorse Ct
640 Grand Ave, G
Carlsbad, CA 92008-2365
760-729-3965
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
CARLSBAD, CA 92011
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
SWPPP INSPECTION FEE TIER 1-Medium BLDG
SWPPP PLAN REVIEW FEE TIER 1-MEDIUM
Total Fees: $1,124.51 Total Payments To Date: $1,124.51
Ccityof
Carlsbad
Permit No: CBR2019-0062
Status:
Applied:
Issued:
Closed -Finaled
01/09/2019
02/26/2019
Permit
Fina led:
Inspector: PBurn
Final
Inspection: 1/7/2020 2:21:39PM
Contractor:
BA WORTHING INC
5145 Avenida Encinas, Ste I
Carlsbad, CA 92008-4322
760-729-3965
Balance Due: $0.00
$290.80
$203.56
$41.00
$175.00
$42.00
$62.00
$2.00
$4.15
$246.00
$58.00
Please take NOTICE that approval of your project includes the 11lmposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
· (cicyof
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
Plan Check ~0) 9' -Cfill_
Est. Value ~<&q3 00
PC Deposit ---,------1·~---
Date _ _._!_,._/~4'.1--'-fl_.j __
Job Address _u,lO"-J:l!~:::...CJ.J--,::beAhx:LW:::,uJ114..~::..'""'-----""cJ-.""-----·Suite: ___ APN: ~ S-GO-6/ -a:>
CT/Project#:. __________ Lot#: ____ Fire Sprinklers: yes~ Air Conditioning: yes@
BRIEF.DESCRIPTIONOFWORK: a-a.d, 14-1 2Q.fc) (<~ \';()~ ~4"'
~ddition/New: \4-1 Living SF, ___ Deck SF, ___ Patio SF, ___ Garage SF
Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __
□ Remodel: l C,,o SF of affected area Is the area a conversion or change of use ? Yes/ No
0 Pool/Spa: ____ SF Additional Gas or Electrical Features? ___________ _
□ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No
Panel Upgrade: Yes/ No
D Reroof: ___________________________________ _
D Plumbing/Mechanical/Electrical Only: ________________________ _
D Other: ------------------------------------
APPLICANT (PRIMARY) PROPERTY OWNER
Name:------,---------:-:----Name: Cle. -t A \i.lJtA-Bit«e
Address: (p4-Q 4i r4<:5c:L ~f"IJ~ (;I Address: JQ.~_i;..hvs.e Cc
City: M:2~ State:(]:¼--Zip: g ... ""'.i}~k ... ·~--=.c,c= ___ .State: lA: Zip: q-z.ou
Phone: 1teO -1'1--1 -?;,!3k.>;:'> ~ Phone:'-........:_,,,_ ~~-=,,,e15....,_ ___________ _
Email: S-A W or,H,it~ :Dre.€ ~«bnc,COM Email: ______________ _
CONTRACTOR BUSINESS
Address:4-o c.t tJi}e.6 Name: ~ A (Al~f~t-
City: V!!f'l?@A:J St~;Zip: g'U()f')
Phone: JtpQ -1 "Zq -Mt,,';;,
Email: 6A ~~~ '.C"'4e! ,r, cnrro
State License: £ Bus. Licen e:'54<:; 2 DO
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he/she Is licensed pursuant to the provisions of the Contractor's License law
{Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}).
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
( OPTION A): WORKERS'COMPENSATION DECLARATION:
I hearby affirm under penalty of perjury one of the following declarations:
0 I have and will maintain a certificate of consent to self •insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued.
}.ti" have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: lnsurance/om~ny Name: C Y'2~ ".CN'~, (' n
Polley No. :e A w ~ <'f I ?::() I '¼ Expiration Date: __,r~---''!.....L;-~---·'' , .
0 Certllicateof-EXempf:ion: I certify that in.the performance of the work for which this permit is issued, I shall not employ any qersOJI In any manner so as to be come
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful, and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code,
Interest and attorney's fees.
CONTRACTOR SIGNATURE: .:_~~~~~.Pr\}.jl!'.1~~~~=-_i_-'--__ 0AGENT DATE: ___,t/'-e__./--'l_':\..___
( OPTION B ): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law
□ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not Intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who does such work
himself or through his own employees, provided that such Improvements are not intended or offered for sale. If, however, the building oi improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). • ·
□ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law}.
□ I am exempt under Section _______ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No
2. I (have/ have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (Include name/ address/ phone/
contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work):
OWNER SIGNATURE: __________________ □AGENT DATE: _____ _
CONSTRUCTION LENDING AGENCY. IF ANY:
I hereby affirm that there is a ~ons~ruction (~~ding ag,e~cy for the performance of the work this permit is issued (Sec. 3097 {i) Civil Code).
Lender's Name: ___________________ _ Lender's Address: ___________________ _
ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanrier Hazardous Substance Accoµnt Act? □ Yes D No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have rE!ad the application and state that the above information ls correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction.
I hereby authorize representative of the aty of Carlsbad to enter upon th~ above mentioned property for Inspection purposes. I AlSO AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE cnv OF CARISBAD AGAINST ALL LIABILITIES, JUDGMENTS, COS"TS AND El(PENSES WHICH MAY IN ANY WAY ACCRUE'AGAINST SAID cnv IN CONSEQUENCE OF
THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit ls required for excavations over 5'0' deep and demolition ~r construction of structures over 3 stories in height
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized
by such permit ls not commenced within 180 days from the date of such permit or if the building or work authorized by such permit ls suspended or abandoned at any time
after the work is commenced for a period of 180 days Ion 106.4.4 Uniform Building Code). l
APPLICANT SIGNATURE: ---=~~~~-----------DATE: __.
1
/_&f'....,__,-").__O\_,__ __
1635 Faraday Ave Carlsbad, CA 92008
B-1
. 760-602-2719 Fax: 760-602-8558
Page 2 of2
Email: Building@carlsbadca.gov
Rev. 06/18
, PERMIT INSPECTION HISTORY REPORT (CBR2019-0062)
Permit Type: BLDG-Residential Application Date: 01/09/2019 Owner: COOWNER BARRE OLE JR AND
ALYSHA L
Work Class: Addition Issue Date: 02/26/2019 Subdivision: CARLSBAD TCT#92-01
Status: Closed -Finaled Expiration Date: 03/24/2020 Address: 1037 Seahorse Ct
Carlsbad, CA 92011-3413
IVR Number: 16388
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Relnspection Complete
Date Start Date
Checklist Item COMMENTS Passed
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
09/23/2019 09/23/2019 BLDG-16 Insulation 104984-2019 Passed Paul Burnette Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
09/26/2019 09/26/2019 BLDG-82 Drywall, 105591-2019 Passed Michael Collins Complete
Exterior Lath, Gas
Test, Hot Mop
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-17 lnterior Lath-Drywall Yes
BLDG-18 Exterior Lath and Yes
Drywall
BLDG-23 Gas-Test-Repairs Yes
01/07/2020 01/07/2020 BLDG-Final 115447-2020 Passed Paul Burnette Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical final Yes
January 07, 2020 Page 2 of 2
PERMIT INSPECTION HISTORY REPORT (CBR2019-0062)
Permit Type: BLDG-Residential Application Date: 01/09/2019 Owner: COOWNER BARRE OLE JR AND
ALYSHA L
Work Class: Addition Issue Date: 02/26/2019 Subdivision: CARLSBAD TCT#92-01
Status: Closed -Finaled Expiration Date: 03/24/2020 Address: 1037 Seahorse Ct
Carlsbad, CA 92011-3413
IVR Number: 16388
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
Date Start Date
05/15/2019 05/15/2019 BLDG-21 091938-2019 Partlal Pass Andy Krogh Reinspection Incomplete
Underground/U nderf
loor Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Waste at new addition, to be connected to Yes
existing in future
05/20/2019 05/20/2019 BLDG-11 092360-2019 cancelled Andy Krogh Reinspectlon Complete
Foundatlon/Ftg/Pler
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
05/21/2019 05/21/2019 BLDG-11 092457-2019 Passed Andy Krogh Complete
Foundatlon/Ftg/Pier
s (Rebar)
07/01/2019 07/01/2019 BLDG-15 096196-2019 Passed Andy Krogh Complete
Roof/ReRoof (Patio)
07/25/2019 07/25/2019 BLDG-21 098681-2019 Passed Paul Burnette Complete
Underground/U nderf
loor Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Waste at new addition, to be connected to Yes
existing in future
08/08/2019 08/08/2019 BLDG-13 Shear 100177-2019 Passed Peter Dreibelbis Complete
Panels/HO (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
09/13/2019 09/13/2019 BLDG-84 Rough 104071-2019 Failed Peter Orelbelbls Relnspection Complete
Combo{14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
09/19/2019 09119/2019 BLDG-84 Rough 104745-2019 Passed Tony Alvarado Complete
Combo(14,24,34,44)
January 07, 2020 Page 1 of 2
City of Carlsbad cbR2017-1434
July 10, 2017
«,<
~ CITY OF
CARLSBAD
I
SPECIAL INSPECTION
AGREEMENT
8-45
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
In accordance with Chapter 17 of the California Bulldlng Code the following must be completed when work being performed
requires special Inspection, structural observation and construction material testing.
>roject/Permit:lei). 'Z&>('f -oor--L Project Address· (0 ~ 1 ~N)<~ CJ--
A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check w you are OWner-Builder
□. (If you checked as owner-builder you must also complete Section B of this agreement.)
Name: (Please print~) --~......,,~7"',: .. -'-<i'z~-----~8~•,------W~o~~--,:-\~-c-+-----
"''"' ~~• I ct-,,;;;;ij
Email·
lam: □Property owner roperty owner's Agent of Record □Architect of Record □Engineer of Record
State of California Registration Numbe~c·--~2~tf'~Z.~8~".f~+~--Expiration Date:'8/~i / '20W
AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the state of California, that I have read,
understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural
observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of
special inspections noted on the ap roved i:,lans a d, equired by the California Building Code.
Signature· Date: 2/7 / lq
8. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (
contractor I builder I owner-builder.
CBC, C 17, Section 1706). This section must be completed by the
Contractor's Company Name:__f2_1lr_1h2.~ t ~y__,.,Nc.cc.,.C..~·------Please check 11 yoo are awn er-Builder o
Name: (Please print) B WOKS Wo ?1:1:< I v\..Ll,
(F1r~t) {M.IJ ~
Mailing Address: ___ f_i'.2_p~o~JO~~'~O~<f~(--~-~~~-~f\...~f::,~~CA-~_1~w~'-B~------
Email:~t7=W=~~~-~•~rJ..<.-<,=~'=M~'-'~IJ"---<'f...,4:~t:<=o~o~,~k=O~""'~----Phone_· _"'t_,_,"'-'()"-_,~1-~Ci.,__~3~~~"~!,-
State of California Contractor's License Number~· _:S_'l_f3_1_b_'-f ____ Expiration Date: 1 / 1 / 'Z,() W
• I acknowledge and, arn aware, of special requirements contained in the statement of special inspections noted on
the approved plans;
• I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the
building official;
• I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and
frequency of reporting and the distribution of the reports: and
• I certify that I will have a qualified person within our (the contractor's) organization to exercise such control.
• I will provide a final report I letter In compliance with CBC Section 1704.1.2 prior to requesting final
inspection.~~.
Signature: ~"---------U Date: -=2.=,{_1-+{~t_'t~-----
B-45 Page 1 of 1 Rev. 08111
MARS INSPECTION INC.
"A Special Inspection Company"
Cell Ph. 619-339-3331 • Email : marsinsp(mmac.com
Project Name:/? 7 J<,11(.-::._ f}s
Project Address: /,(")3 I .> .... ,, frbl2 52
Architect: /..5~ k ,:;., b,5/)r--,/
Inspection Report
Page: / of I Report#: _o____;=:o:....:.~-=----
C' r-Permit #: <~.tfrz ;lot<; dOeb :?--
File #: r"' / ,1---
Engineer: ,
~ /7 < i J. Contractor: -(.,,,Uc;, 1 I ~ Other: A-/
DSA #: ,,,,.. :Y'
,f
~ I
INSPECTION MATERIAL SAMPLING
Structural Steel H.S. Bolts --
_Masonry -Prisms
-Concrete -Mortar/Grout
_Fireproofing _Cone. Cylinders
/Epoxy _Fireproof
Shear Wall Other: --
Other: Other: --
Other: Other: --
Other: Other:
□ Visual Weld □ Ultra Sonic Test
1 . ObseNed Welding By Certified Welders
2. All Welds □ Single Pass Fillets
Qty.
-
-
-
-
-
-
-
-
MATERIAL DESCRIPTION
H.S. Bolts -
Cone. PSI -
Grout PSI -
Mortar PSI -
Steel -
-Elect/Wire
~proof ,
=Other: .5~x f Yr
Other: ef_ ,:/,-;:? S"6 ~
E:16xy Anchors
□ Rebar
□ Full Pen Groove Welds
~tinuous
3 . Process Used □FCAW □SMAW
INSPECTION CHECKLIST
~Plans/Specs
~learances
./"Positions
_;:;:;>~izes
_Laps
Consolidation -
_Torque Ft. Lbs.
Other: -
Other:
□ Concrete Placement
□ Shear W all Nailing
□ Shop E:tField
□ Periodic
I
lo
CERTIFICATION OF COMPLIANCE: All reported work, unless otherwise noted, complies with approved plans, specifications and
applicable sections of the building codes. This report covers the locations of the work inspected and does not constitute opinion or
project control.
Inspector: x ~~ /1. J3tJ kt/ Sb# ':f·p Y ~ 7 Date
lnsp. Date: Day 1: 1/r~ G,-Day 2: I Day 3: I Day 4: I Day 5: I
Time Start: //
Time Stop: r_yfrrt~
Copies of report submitted to:
MARS INSPECTION INC.
"A Special Inspection Company"
Cell Ph. 619-339-3331 • Email: marsinsp~mac.com
~ Inspection Report 1 Project Name:...:;,_/J-7-.::A....:..:....:if"..L..6,_,L....-_,1,_4_,-l';,___,,::S.:....-_____ Page: , / of ___ Report#: L-=.j _-,=-...L.J ___ _
Project Address: IJ 7 _; ,1 j,, .-C · T Permit#: 2" & --2,r, 1 0~' /?
Architect:-"-___ '.._t;;...._:),;.::;.:.,=,t1"--__.1--=) ___ ...;____ File#: _r'\o-....,,..-"-"-----------------
DSA #: -......:..~--------------Engineer: _J
Contractor: 1 3' /J ./U:; •///--.._
·,
INSPECTION MATERIAL SAMPLING ~ \arv MATERIAL DESCRIPTION INSPECTION CHECKLIST
Structural Steel H.S. Bolts --H.S. Bolts --Plans/Specs ----
_Masonry -Prisms --Cone. PSI __...clearances
-Concrete -Mortar/Grout --Grout PSI ~Positions
_ FireB,roofing _Cone. Cylinders --Mortar PSI /sizes
~Epoxy _Fireproof --Steel _Laps
-Shear Wall -Other: --Elect./Wire -Consolidation
-Other: -Other: Fireproof Torque Ft. Lbs. -/'other: _5,,.:--,,_./JS~ (c.1-x, ·r-
-Other: -Other: -• Other: rco :J,!c:.~ -
Other: Other: Other: Other:
□ Visual Weld □ Ultra Sonic Test
_.,,,..
la Epoxy Anchors □ Concrete Placement
1 . Observed Welding By Certified Welders □ Rebar □ Shear Wall Nailing
2. All W elds □ Single Pass Fillets □ Full Pen Groove Welds □ Shop D -flerd
□ ontinuous □ Periodic
3. Process Used □FCAW □SMAW
f
CERTIFICATION OF COMPLIANCE: All reported work, unless otherwise noted, complies with approved plans, specifications and
applicable sections of the building codes. This report covers the locations of the work inspected and does not constitute opinion or
project control.
Inspector: x ,-...........___ M Rot,.> kt/ Sh :if l:D K =8 l
Date
lnsp. Date: Day 1: It.,. J {~ Day 2: I Day 3: I Day 4: I Day 5: I . Time Start: I
Time Stop: ✓ /-Jl-f ~
Copies of report submitted to:
✓• EsG1I
A SAFEbuilfCompany
DATE: February 18, 2019
JURISDICTION: Carlsbad
□ APPLICANT
□ JURIS.
PLAN CHECK#.: CBR2019-0062
PROJECT ADDRESS: 1037 Seahorse Ct.
SET II
PROJECT NAME: Addition and Remodel to Barre Residence
□
□
□
□
□
□
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Brooks Worthing
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Telephone#: 760-729-3965 Person contacted: 7ro s W~ing
Date contacted: (b~)
Mail Telephone Fax In Person
Email: baworthinginc@yahoo.com
REMARKS: Applicant to sign soil stamp at t e
By: Kat Frankowski
EsGil
2/11/2019
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: January 17, 2019
JURISDICTION: Carlsbad
✓• EsG1I
A SAFEUuitt' Company
PLAN CHECK#.: CBR2019-0062
PROJECT ADDRESS: 1037 Seahorse Ct.
SETI
PROJECT NAME: Addition and Remodel to Barre Residence
□ APPLICANT
□ JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
IZJ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
IZJ The applicant's copy of the check list has been sent to:
Brooks Worthing
D EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Brooks Worthing Telephone#: 760-729-3965
Date contacted: (by: )
Mail Telephone Fax In Person
0 REMARKS:
By: Kat Frankowski
EsGil
1/10/2019
Email: baworthinginc@yahoo.com
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad CBR2019-0062
January 17, 2019
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: CBR2019-0062 JURISDICTION: Carlsbad
PROJECT ADDRESS: 1037 Seahorse Ct.
FLOOR AREA:
Addition = 14 7 SF
Remodel= 150 SF
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 1/9/2019
DATE INITIAL PLAN REVIEW
COMPLETED: January 17, 2019
FOREWORD (PLEASE READ):
STORIES:
HEIGHT:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 1/10/2019
PLAN REVIEWER: Kat Frankowski
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC,
2015 UPC, 2015 UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list {or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad CBR2019-0062
· January 17, 2019
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Kat Frankowski
BUILDING ADDRESS: 1037 Seahorse Ct.
BUILDING OCCUPANCY:
PLAN CHECK#.: CBR2019-0062
DATE: January 17, 2019
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
Addition 147
Remodel 150
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
------·--.. 1997 UBC Budding Permit Fee ...
1997 UBC Plan Check Fee
Type of Review:
D Repetitive Fee
____ -~ Repeats
0 Complete Review
D Other
D Hourly
EsGil Fee
Reg. VALUE
Mod.
D Structural Only
Comments: In addition to the above fee, an additional fee of$
$ /hr.) for the CalGreen review.
($)
31,893
31,893
$177.691
is due ( hour@
Sheet of
Carlsbad CBR2019-0062
· January 17, 2019
PLANS
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one of
two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700.
The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire
Departments.
2. Bring Ill\lQ corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake
Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of
plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City
Planning, Engineering and Fire Departments until review by EsGil is complete.
2. All sheets of plans must be signed by the person responsible for their preparation.
(California Business and Professions Code).
3. Clearly dimension building setbacks from property lines, street centerlines, and from all
adjacent buildings and structures on the site plan. Section R106.2.
Add setback to roof overhang.
4. Please check window size in kitchen. Its size in the elevation doesn't seem to match
called out size.
5. Please complete Carlsbad special inspection form at the end of this list.
FIRE PROTECTION
Use this table if the building DOES NOT have an automatic fire sprinkler system.
' Min. Fire Separation Exterior Wall Element Min. Fire Rating Distance ----..
Not Allowed N/A <2 feet ·-· -· _,_ -
Projections (Fire-Resistance Rating) 1-hour on the ;,, 2 feet to 5 feet underside•
(Not Fire Rated) 0 hours ;,, 5 feet . -
FOUNDATION REQUIREMENTS
6. Note on plans that surface water will drain away from building and show drainage
pattern. The grade shall fall a minimum of 6" within the first 1 O feet. Section R401.3.
STRUCTURAL
7. Please provide a nailing schedule.
Carlsbad CBR2019-0062
· January 17, 2019
8. Provide wall legend, show stud size and spacing.
ELECTRICAL
9. Provide a legend for symbols on plans.
PLUMBING
10. Detail the kitchen island sink venting.
11. Specify on the plans: Water conserving fixtures: New water closets shall use no more
than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8 GPM, lavatories
are limited to 1.2 GPM, and showerheads may not exceed 1.8 GPM of flow. CPC
Sections 407, 408, 411, 412.
Update note.
RESIDENTIAL GREEN BUILDING STANDARDS
The California Building Standards Commission has adopted the Green Building Standards
Code and must be enforced by the local building official. The following mandatory requirements
for residential construction must be included on your plans. CGC Section 101.3. The
Standards apply to newly constructed residential buildings, along with additions/alterations
that increase the building's conditioned area, volume or size. CGC Section 301.1.1. Provide a
sheet on the plans labeled "Green Building Code Requirements" and include the
following notes as applicable.
SEVERAL NOTES ARE MISSING, INCOMPLETE OR OUTDATED. PLEASE REVIEW NOTES
AND UPDATE AS NEEDED.
12. Storm water drainage/retention during construction. Note on the plans: Projects
which disturb less than one acre of soil shall manage storm water drainage during
construction by one of the following: A. Retention basins. B. Where storm water is
conveyed to a public drainage system, water shall be filtered by use of a barrier system,
wattle or other approved method. CGC Section 4.106.2.
13. Grading and paving. Note on the plans that site grading or drainage system will
manage all surface water flows to keep water from entering buildings (swales, water
collection, French drains, etc.). CGC Section 4.106.3. Exception: Additions not altering
the drainage path.
14. Indoor water use. Show compliance with the following table, per CGC Section 4.303.1.
FIXTURE FLOW RATES
FIXTURE TYPE MAXIMUM FLOW RATE
Water closets 1.28 gallons/flush
Urinals (wall-mounted) 0.125 gallon/flush
Carlsbad CBR2019-0062
January 17 2019 •
Urinals (others) 0.5 gallon/flush
Showerheads 1.8 gpm @80 psi
Lavatory faucets 1.2 gpm @ 60 psi1
Kitchen faucets 1.8 gpm@60 psi
Metering faucets 0.25 gallons per cycle
1. Lavatory faucets shall not have a flow rate less than 0.8 gpm at 20 psi.
15. Note on the plans that when a shower is provided with multiple shower heads, the sum
of flow to all the heads shall not exceed 1.8 gpm @ 80 psi, or the shower shall be
designed so that only one head is on at a time. CGC Section 4.303.1.3.2.
16. Note on the plans that landscape irrigation water use shall have weather or soil based
controllers. CGC Section 4.304.1.
17. Recycling. Note on the plans that a minimum of 65% of construction waste is to be
recycled. CGC Section 4.408.1.
18. Recycling. Note on the plans that the contractor shall submit a Construction Waste
Management Plan, per CGC Section 4.408.2.
19. Operation and maintenance manual. Note on the plans that the builder is to provide
an operation manual (containing information for maintaining appliances, etc.) for the
owner at the time of final inspection. CGC Section 4.410.1.
20. Pollutant control. Note on the plans that during construction, ends of duct openings are
to be sealed, and mechanical equipment is to be covered. CGC Section 4.504.1.
21. Pollutant control. Note on the plans that VOC's must comply with the limitations listed
in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and 4.504.5 for: Adhesives,
Paints and Coatings, Carpet and Composition Wood Products. CGC Section 4.504.2.
22. Interior moisture control. Note on the plans that concrete slabs will be provided with a
capillary break. CGC Section 4.505.2.1.
23. Interior moisture control. Note on the plans that the moisture content of wood shall not
exceed 19% before it is enclosed in construction. The moisture content needs to be
certified by one of 3 methods specified. Building materials with visible signs of water
damage should not be used in construction. The moisture content must be determined
by the contractor by one of the methods listed in CGC Section 4.505.3.
24. Indoor air quality. Note on the plans that bathroom fans shall be Energy Star rated,
vented directly to the outside and controlled by a humidistat. CGC 4.506.1.
ENERGY CONSERVATION
25. Section A shows R-13 insulation while T-24 calls for R-15. Please coordinate.
. Carlsbad CBR2019-0062
January 17, 2019
26. All domestic hot water piping to have the following minimum insulation installed: ½" pipe
(1/2" insulation);¾" pipe (1" insulation); 1"to 1-½" pipe (1-½" insulation). CPC 609.11 &
ES 150.0U)
a) Additionally, the ½" hot water pipe to the kitchen sink, and the cold water pipe
within 5' of the water heater both require 1" minimum insulation. ES 150.OU)
Update note.
27. Below grade hot water piping is required to be installed in a waterproof and non-
crushable sleeve or casing that allows for replacement of both the piping and insulation.
Residential ventilation requirements: ES 150.0(o)/ASHRAE 62.2
28. Kitchens require exhaust fans with a minimum 100 cfm ducted to the exterior. Detail
compliance by including a complying exhaust fan or a ducted range hood to the exterior.
MISCELLANEOUS
29. To speed up the review process, note on this list (or a copy) where each correction item
has been addressed, i.e., plan sheet, note or detail number, calculation page, etc.
30. Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and
where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list? Please
indicate:
Yes □ No □
31. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208,
San Diego, California 92123; telephone number of 858/560-1468, to perform the plan
review for your project. If you have any questions regarding these plan review items,
please contact Kat Frankowski at EsGil. Thank you.
STORM WATEB PQLLI.ITION P~ENTION NOTES
1, ALL NECESSARY EQUIPMENT AND MAlERIALS SHALL BE
AVAILABLE ON Sl1E lD FACILITATE RAPID INSTALLATION
OF EROSION AND SEDIMENT CONlROL BMPs Vr!IEN RAIN
IS EMINENT,
2. lliE 01\NER/CDNlRACTOR. SHALL RESTORE ALL EROSION
CONlROL DEVICES lD WORKING ORDER lD lliE SA 11SF ACTION
OF lliE CITY INSPECTOR AFlER EACH RUN-OFF PRODUCING
RAINFALL
3. lliE OWNER/CONlRACTOR SHALL INSTALL ADDITIONAL EROSION
CONlROL MEASURES AS MAY BE REQUIRED BY lliE CITY
INSPECTOR DUE lD INCOMPLETE GRADING OPERA 1IONS OR UNFORESEEN CIRCUMSTANCES Vr!IICH MAY ARISE.
4. ALL REMOVABLE PROlECTIVE DEVICES SHALL BE IN PLACE
AT 11iE END OF EACH WORKING DAY \\!IEN lliE AVE (5)
DAY RAIN PRDBABIUTY FORECAST EXCEEDS FORTY PECENT
(4o:c), SILT All) OlliER DEBRIS SHALL BE REMOVED AFTER
EACH RAINFALL
5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM
AGGREGATE.
6, ADEQUATE EROSION AND SEDIMENT CONlROL AND PERIME'JER
PROTECllON BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINID.
7, lliE CITY INSPECTOR SHALL HAVE lliE AUlliORJTY lD ALlER
lHIS PLAN DURING OR BEFORE CONSlRUCllON AS NEmm
TO ENSURE COMPLIANCE Wl1H CITY STORM WAlER QUALITY REGULA 110NS.
OWNER'S CERTIFICATE:
I UNDERSTAND AHO ACKND\\I.EDGE lHAT I MUSTt (t) IM!'LEIIENT
BEST MANAGEMENT PRACTICES (BW'S) DWIING GDNSlRUCTIGN
ACTl'll'IIES TO 1HE MAXiMUll EX1ENT PRAC11CA91.E TO AYOJD
lliE MOBIUZA110N 01' POWJTAHlS SUCH AS S£Dl1IENT AHO TO
AVOID lHE EXPOSURE OF STORM WATER TO COHSlRUCTION RfLAlED POWITAHlS: AHO (2) Atll!ERE TO, AND AT All 1IMES,
COW'LY WilH lHIS CITY APPROVED 11ER 1 GDNSlRUCTIGN S\\PPP lHROUGHOUT 1HE OURA1IOH 01' 1HE CGNSIRUC1ION AC1111TIES UNTIL lHE CONS1RUC110N WORK IS C0MPlf1£ AHO APPROVED
BY~~= \P IX) W£)['V'II~ OWN:;z;~E (PRJHT) ~ 1, q '•-
OWN ~GNAruRQ ~
E-29
L/
' STORM WATER COMPLIANCE FORM
TIER 1 CONSTRUCTION SWPPP
E-29
CB KJ-019-():){ol_
SW
BBST MANAGEMENT-PRACTICES (BMP) SELECTION TABLE
Best Management PracUce•
(BMP) OescripUon ➔
CASQA Deslgnallon ➔ ..
.fil9slBl!!!!!L
hall Sawculllng
alwork
on£'1~:;e lnstgUollon Stucco ortor Work
Waite OlsD0$0l
StpglnqJt.a!Down Area
Egutpment Stjatn.tenanca on:'{!;;eltna
Hazardous bslance Ug/S ge
Dewalerlng
..... """" I BIii's
.s
: .J ~= 51 u :!i j is " :ii = ~ ,el i • .t olla " i.
,_ m ~ ~ s s 2
Sediment Conltol SMPs
~ Ii
! ~ I t .S·
~ /fl
e-
8 -.g .!if ~l Q & f 'I! ~ ! 1t a
Iii .:; 15 I!! ill:!! -... ~"' "' ... i ill ill 1k lH ill ill
1-=..
j j u ] j 5 Si ~ .s .S! 11 Ji ~.ll ~~ ind: 11 .s g "'~
5! ! I il:
...,, ... .,...,
Managllllelll SMPs
f i I i t
1& ii ~
§ ii &D I """ .... ,!'i! 11 :!!a
i.~ ~a
j; ... :J; i J, z z z
Waste Managtmenl and Malerlals ~ConlrolBMPs
"D & "D 5 i i I ~. .s a .,. J!I
:S i i .si ~& i&
:.: g .. ... E.-. ,ii ' .ii~ -ii i -~ '5 if b;ga ![iii Da iw i ii :;.a iSi !j 8:i
i I ilil i Ii I l I ~
Slle Atem Across Dirt
J other fnst>;
Instructions: 1, Check the box to the left of all oppUcable conslnlctlon ocUvlty (flrat column) expected to occur during construction.
2. Located q!~_g the loll of the Bl.IP Table Is o list of BMP'a with It's cotresp_ondklg Callfomlo Stonnwoler Quallly AssocioUon (CASOA) destanatlon number, Choose one or more swa ,w Intend to use during c:onstrucUon from lh, 11st. Check th• box where the chosen activity row lntemcla with thi BMP" cahnntl.
3. Rtfar to the CASQA conalnlcllon handbook, for lnfonnaUon and: ~e~ q~ the chosen 81.1Pa and how to oppJy them to th• projecL
SHOW THE LOCATIONS OF ALL CHOSEN BMPsABOVE
ON THE PROJECTS Sl]'E Pl.AN/EROSION CONTROL PLAN.
SEE THE REVERSE SIDE OF THIS SHEET FOR A SAMPLE
EROSION CONTROL Pl.AN.
-BMP's are subject to field inspection-
Page 1 of 1
PROJECT INFORMATION
Sita-,,, '":">7 ~h«'~\d-
-· Pared Number. 2.14 ~ '5:50-~/ 00
Emergency Contoct:b:L lllA..-~
Name: C. ~ J ric:I 8v""
24 Hour Phone: 7'6C '4 t, -(llt.,j-•
Construction Threat to Stoma Water Quollty
(a,eck Box)
0 MEDIUM ~l'I.
REV 02/16