Loading...
HomeMy WebLinkAboutPRE 2021-0007; ROBERTSON RANCH PLANNING AREA 11; Admin Decision LetterMay 19, 2021 Adrien Taghdiri Shapell Properties, Inc. 11200 Corbin Ave., Suite 201 Porter Ranch, CA 91326 C City of Carlsbad El Fl LE COPY tif .. ,1~) s-fa 0 ' SUBJECT: PRE 2021-0007 (DEV2021-0051)-ROBERTSON RANCH PLANNING AREA 11 APN: 208-195-01-00 Thank you for submitting a preliminary review for a land use change and site plan layout for a contemplated mixed-use project consisting of commercial and multi-family residential uses at the vacant site within Robertson Ranch Planning Area 11. The project site, an approximately 14.33-acre lot, is currently graded but is vacant. In response to your application, the Planning Division has prepared this comment letter. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. This preliminary review does not represent an in-depth analysis of your project. It is intended to give you feedback on critical issues based upon the information provided in your submittal. This review is based upon the plans, policies, and standards in effect as of the date of this review. Please be aware that at the time of a formal application submittal, new plans, policies, and standards may be in effect and additional issues of concern may be raised through a more specific and detailed review. Planning: General 1. General Plan and zoning designations for the property are as follows: a. General Plan: Community Facilities/Local Shopping Center (CF/L). b. Zoning: Planned Community (P-C). c. Specific Plan: Robertson Ranch Master Plan (MP 02-03(H)) -Planning Area 11. The underlying zoning is Community Facilities/Local_Shopping Center (C-F/C-L). The C-F zoning designation applies to 3 acres of the site and the C-L Zoning designation applies to the remainder of the site. 2. The project requires the following permits: a. General Plan Amendment (GPA). The proposed R-23 Residential land use designation (15-23 dwelling units per acre) requires a GPA to eliminate the CF land use designation. Community Development Planning Division I 1635 Faraday Avenue Carlsbad, CA 92008-7314 I 760-602-4600 I 760-602-8560 f I www.carlsbadca.gov PRE 2021-0007 (DEV2021-0051)-ROBERTSON RANCH PLANNING AREA 11 May 19, 2021 · Pa e 2 b. Specific Plan Amendment (AMEND!. The project requires an amendment to the Robertson Ranch Specific Plan to eliminate the underlying zoning of Community Facilities (C-F) and introduce the underlying zoning of Residential Density-Multiple Zone (RD-M) to correspond with the proposed GPA to add the R-23 land use designation. c. Carlsbad Tract Map (CT). To subdivide the lot into five or more lots. Approximately 9.14-acres of the site is proposed as Local Shopping Center and approximately 5.19-acres of the site are proposed as R-23 Residential. d. Non-Residential Planned Development Permit (PUD). The project requires a PUD if the commercial parcel will have separate ownership lots or if there is shared access with the residential community. e. Site Development Plan (SDP). Development of the proposed commercial and residential development would each require approval of an SDP. f. Special Use Permit (SUP). The project is required to obtain a SUP because it is located within a Scenic Preservation Overlay Zone. 3. City staff are not supportive of the request to eliminate the Community Facilities land use designation for the site. Approximately 1,450 additional dwelling units are identified as potentially being built within a two-mile distance of the project site per the most recently adopted City Housing Element Update -2021-2029. Those additional residents will need Community Facilities as envisioned within the Robertson Ranch Master Plan. Furthermore, the Housing Element Advisory Committee, which was appointed to evaluate the potential rezone and upzoning of sites, did not identify the site as a location for additional dwelling units. Furthermore, nearby land use decisions have been made with the expectation that the Community Facilities and Local Shopping Center uses envisioned within the Robertson Ranch Master Plan would be built. If the applicant desires to construct residential units on- site, staff recommends the applicant explore ways to introduce a residential component to the development while still maintaining the development of Local Shopping Center and Community Facilities uses envisioned for the site. Please note that the Robertson Ranch Master Plan specifies that residential uses may be built above the first story of a proposed development within Planning Area 11. 4. City staff has received written opposition from the Robertson Ranch community with regards to the proposed land use change and related development proposal. Please refer to the attached opposition letter from the community. A total of 235 signatures were collected in opposition to the proposed land use change and related development proposal. 5. Carlsbad Municipal Code (CMC) Section 21.25.030 specifies that the Community Facilities designation identified on sites within a Master Plan shall be reserved for a minimum time period often years. Per city staff interpretation of this code section, the ten-year period shall commence when final inspections have been approved for one hundred percent of the units in the first residential planning area of the West Village of the Robertson Ranch Master Plan. According to city records the one hundred percent completion of the first planning area of the West Village of the Robertson Ranch Master Plan was Montecito Apartments, which received building final on March 26, 2019 (The other planning areas received final inspections as follows: 1) The Terraces, 6/21/2019; 2) The Bluffs, 6/24/2019; 3) The Ridge 7/.11/2019; and 4) The Vistas, 9/18/2019). As a result, the site has not been available for Community Facilities uses for a period of ten years and is not eligible for a land use change to eliminate the Community Facilities land use designation until March 26, 2029. PRE 2021-0007 (DEV2021-0051}-ROBERTSON RANCH PLANNING AREA 11 May 19, 2021 Pa e 3 6. Should the applicant wish to proceed with a formal application of this proposal despite Comment No. 3, 4 and 5 above, staff has provided the following general comments: 7. Development Standards. The project shall comply with the development standards of the C-L and RD- M zoning designation and any applicable standards of the Planned Development Ordinance, Robertson Ranch Master Plan and the El Camino Real Corridor Development Standards, including but not limited to the following: a. Local Shopping Center (C-L) Ordinance. Please refer to Carlsbad Municipal Code (CMC) Chapter 21.31 to ensure the project complies. b. Residential (RD-Ml Ordinance. Please refer to Carlsbad Municipal Code (CMC) Chapter 21.24 to ensure the project complies. c. Planned Development Ordinance. Please refer to Carlsbad Municipal Code (CMC) Chapter 21.45 to ensure the project complies. d. Robertson Ranch Master Plan (MP 02-03(H)). Please refer to the development standards and design guidelines contained within the Robertson Ranch Master Plan as it applies to the project and Planning Area 11. e. El Camino Real Corridor Development Standards. Please refer to the development standards and design guidelines of the El Camino Real Corridor Development Standards. 8. Parking. The parking requirements for residential and commercial uses can be found in Carlsbad Municipal Code (CMC) Chapter 21.44. Please be aware that the parking calculation presented in the overall site plan are inaccurate. Please review the attached planning red lines for the correct parking totals. 9. Landscape. A formal submittal will need to include concept landscape and irrigation plans. The concept plans shall be designed in accordance with both the Robertson Ranch Master Plan Landscape Guidelines and the City of Carlsbad's Landscape Manual Policies and Requirements. The City of Carlsbad's Landscape Manual document can be found on the Planning Division's web page at the following address: http://www.carlsbadca.gov/civicax/filebank/b1obdload.aspx?Blob1D=24086 10. Climate Action Plan. New requirements related to the city's goals to reduce greenhouse gas (GHG) emissions will likely impact development requirements of this project. A formal application submittal will need to include a completed Climate Action Plan Checklist (Form P-30) to determine what requirements will apply to the project. New GHG reduction requirements are related to energy efficiency, photovoltaic, electric vehicle charging, water heating and traffic demand management requirements, as set forth in the California Green Building Standards Code and in CMC Chapters 18.21, 18.30 and 18.51 which is available on the city's website at the following address: http://www.gcode.us/codes/car1sbad/view.php?topic-18&frames-on PRE 2021-0007 (DEV2021-0051)-ROBERTSON RANCH PLANNING AREA 11 May 19, 2021 Pa e4 To the extent that new GHG reduction requirements are in effect at the time of application for grading or building permits, the project will be required to comply with the effective requirements even if different than what is proposed in the project's planning approvals. GHG reduction requirements may impact, but are not limited to, site design and local building code requirements. If incorporating new GHG reduction requirements results in substantial modifications to the project after planning approvals are obtained, then prior to issuance of grading or building permits, the applicant may be required to submit and receive approval of a Consistency Determination or an Amendment application for the project through the Planning Division. 11. Trash: Please contact Waste Management for approval of trash location(s) and operations. 12. Cultural Resources Assessment. As the project is located in an area of known cultural sensitivity, please submit a cultural resources assessment prepared by a qualified professional. l:he study shall comply with the city's Tribal, Cultural and Paleontological Resources.Guidelines. Please be advised the Guidelines require a Luiseno Native American monitor to be present for any field survey or work conducted by an archaeologist. Please see the link below for additional information. https://www.carlsbadca.gov/civicax/filebank/b1obdload.aspx?Blob1D-34010 13. Noise Analysis. As the subject parcel is adjacent to El Camino Real, please submit a noise analysis analyzing the project's consistency with the General Plan and Noise Guidelines Manual. The Noise Guidelines Manual can be found online at: https://www.carlsbadca.gov/civicax/filebank/b1obdload.aspx?Blob1D=24094 14. Stakeholder Outreach. The project is subject to City Council Policy Statement No. 84, Development Project Public Involvement. A notice sign is required to be posted onsite by the applicant and an early public notice is required to be prepared by the applicant and mailed to all owners located within a 600-foot radius of the property. In addition, enhanced stakeholder outreach and a follow-up summary report are required. Please see attached Policy for details. https://www.carlsbadca.gov/civicax/filebank/blobdload.aspx?Blob1D=35S78 15. This preliminary review does not constitute a complete review of the proposed project and additional items of concern may be identified upon formal project application submittal. Please refer to the Development Permits P-2 checklist for all of the necessary required items prior to formal submittal, which is available on the city's website at the following address: https:ljwww.carlsbadca.gov/civicax/filebank/blobdload.aspx?BloblD-24116 All necessary application forms, submittal requirements, and fee information are available at the Planning counter located in the Faraday Building at 1635 Faraday Avenue or online at http://www.carlsbadca.gov/services/depts/planning/default.asp. You may also access the General Plan Land Use Element and the Zoning Ordinance online at the website address shown; select Department Listing; select Planning Home Page. Please review all information carefully before submitting. PRE 2021-0007 (DEV2021-0051}-ROBERTSON RANCH PLANNING AREA 11 May 19, 2021 Pa e 5 Engineering: 1. This project appears to inconsistent with Section 21099 of the Public Resources Code, therefore staff may not be able to support this project. This code states that the criteria for determining the significance of transportation impact must promote: 1) reduction of greenhouse gas emissions; 2) development of multimodal transportation networks; and 3) a diversity of land uses. Therefore, this project proposed land use change does not appear to promote a diversity of land uses. 2. An analysis for Vehicle Miles Travelled (VMT) is required. This analysis may need to include the effect of removing the community facilities land use on the surrounding residential neighborhoods. This project is most likely to have a significant transportation impact that is not mitigatable to a less than significant impact. 3. A transportation impact analysis (TIA) will be required. Prior to preparation of a TIA, the applicant is required to meet with city staff to develop a scoping agreement for the TIA. 4. A transportation demand management (TDM) plan will be required. 5. A transportation systems management (TSM) mitigation is required for this project. 6. Complete the city's Storm Water Standards Questionnaire (Form E-34). This questionnaire will guide you and the City in determining what type of reports and storm water mitigation must be completed to satisfy state and City storm water quality requirements. The questionnaire can be obtained on the city's web site. Preliminary analysis suggests that the project is a 'Priority Development Project' and shall provide two Storm Water Quality Management Plan (SWQMP) per the city's E-35 template. The template is available on the city's website. Additionally, the project appears to be subject to hydromodification requirements and will be required to implement hydromodification facilities. 7. A preliminary title report dated within 6 months of the application date is required with the submittal of a discretionary application and final engineering application. Show and label on the plans, all easements listed in said report. If the easement cannot be shown, list the easement on the plan and state "non-plottable". 8. This project is required to provide a preliminary grading plan with the submittal of a discretionary application and is subject to a final engineering grading plan and grading permit. 9. This project appears to propose the subdivision of 2 parcels which will be subject to a tentative parcel map as a discretionary application and submittal of parcel map for recordation. 10. A geotechnical report and drainage study will be required with the submittal of a discretionary application and final engineering application. 11. It appears that reciprocal access is required for the project including reciprocal access for pedestrians, parking and drainage. Show and label on the plans, the reciprocal access. 12. Show and label on the plans, the proposed water including potable, irrigation, and fire service and sewer services that will be serving the site. PRE 2021-0007 (DEV2021-0051) -ROBERTSON RANCH PLANNING AREA 11 May 19, 2021 Pa e 6 13. Provide on the civil plans, the method of drainage for the subject property including storm drain system. 14. Show and label on the plans, the existing and proposed grades including contours and spot elevations. 15. Show and label on the plans, the truck turning movements for the loading bays of the "major" building structure. 16. Provide on the plans, the finish floor and pad elevation for each of the buildings/structures. 17. Show and label on the plans, the adjacent structures/buildings and contours within 25-ft of the project boundary. 18. Provide a vicinity map, water (GPD), sewer (EDU), and traffic (ADT) demands, earthwork quantities of cut, fill, import, export and remedial in cubic yards, legal description of the property and assessor parcel number on the title sheet of the plans. Building: 1. New construction covered multi-family dwellings to be complaint with CBC Chapter 11A accessibility requirements. 2. Accessible parking to be on the shortest route to covered unit entrances. If you would,like to schedule a meeting to discuss this letter with the commenting departments, please contact Cliff Jones at the number below. You may also contact each department individually as follows: • Planning Division: Cliff Jones, Principal Planner, at (760) 602-4613. • Land Development Engineering: Kyrenne Chua, Project Engineer, at (760) 602-2744 • Building Division: Jason Paisut, Building & Code Enforcement Manager, at (760) 602-2788 Sincerely, DON NEU, AICP City Planner DN:CJ:cf c: Paul Klukas, 1530 Faraday Ave., Suite 100, Carlsbad, CA 92008 Kyrenne Chua, Project Engineer HPRM/File Copy Data Entry Attachments: Robertson Ranch Community-Project Opposition Letter Plannlng Redlines