HomeMy WebLinkAboutSDP 16-04; CARLSBAD OAKS NORTH LOT 17; FINAL SOILS REPORT; 2018-12-26TABLE OF CONTENTS
SECTION PAGE
1.0 SITE DESCRIPTION ................................................................................................................ 1
2.0 FILL PLACEMENT .................................................................................................................. 1
3.0 TESTING ................................................................................................................................... 2
4.0 ADDITIONAL CONSTRUCTION OBSERVATION .............................................................. 2
5.0 CONCLUSIONS AND RECOMMENDATIONS .................................................................... 3
6.0 LIMIT A TIO NS .......................................................................................................................... 3
TABLES
TABLE!
TABLE IA
TABLEIB
TABLE IC
TABLE ID
TABLElE
TABLE IF
TABLE II
FIGURES
FIGURE 1
FIGURE2
COMP ACTION TEST SUMMARY
COMP ACTION TEST SUMMARY (ELECTRICAL TRENCH)
COMPACTION TEST SUMMARY (STORM DRAIN)
COMPACTION TEST SUMMARY (SEWER)
COMP ACTION TEST SUMMARY (FIRE LANES)
COMPACTION TEST SUMMARY (WATERLINES)
COMPACTION TEST SUMMARY (RETAINING WALLS)
LABORATORY TEST DATA
SITE INDEX MAP
COMP ACTION TEST LOCATION MAP
\\ESC_SERVER\Projects\10-13000 to 10-13999 Projects\! 0-1 35830\Rpt_As-Graded Final.doc
Final As-Graded Geotechnical Report Page 1
Proposed Carlsbad Oaks N01th Business Park, Lot 17
Whiptail Loop, Carlsbad, California
December 26, 2018 CTE Job No. 10-135830
1.0 SITE DESCRIPTION
The subject site, identified as Lot 17 within the Carlsbad Oaks N01th Business Park, is located on
the north side ofWhiptail Loop in Carlsbad, California (Figure 1). The improvement area consists
of a previously graded and currently undeveloped building pad. Initial grading of the subject site
and surrounding lots took place in 2007 under the observation of others (as described in reference
Geocon, 2016), and consisted of placement of an approximately minimum five-foot thick cap of
compacted fill materials over native granitic rock. The site is bounded by developed lots to the west
and south (Lots 18 and 13, respectively), residential homes to the east, and open land to the north.
Recent project work summarized herein consisted of excavation and compaction of subgrade
materials for a proposed building pad, pavement areas, and associated improvement areas, and the
construction of a Mechanically Stabilized Earth (MSE) wall.
2.0 FILL PLACEMENT
Existing subgrade materials were overexcavated in general conformance with the project
geotechnical documents and plans. Previous grading, performed under the observation of others,
generally resulted in a building pad where at least two feet of compacted fill underlies bottoms of
proposed footings. Localized overexcavation to accommodate deeper footings (e.g., loading dock
footings) was performed as part of the recent grading described in this report, along with surficial
grading to achieve finished pad grade. Overexcavation bottoms were confirmed as firm and
competent by a CTE representative, and then scarified and moisture conditioned prior to placement
of new fill materials, under periodic observation by a CTE representative.
\\ESC _ SER VER\Projects\ 10-13000 to 10-13999 Projects\ 10-13583G\Rpt_ As-Graded Final.doc
Final As-Graded Geotechnical Report Page2
Proposed Carlsbad Oaks North Business Park, Lot 17
Whiptail Loop, Carlsbad, California
December 26, 2018 CTE Job No. 10-13583G
Fill materials were moisture conditioned, placed, and compacted in lifts at above optimum moisture
content. Based on the field results, compaction in the tested areas was performed to a minimum 90
percent relative density (95 percent in pavement areas), as determined by ASTM D1557. Grading
was performed using standard heavy-duty construction equipment.
3.0 TESTING
Field-testing, as scheduled by the contractor, was performed to supplement the noted field
observations. Testing of compacted fill addressed by this report was conducted between April, 2017
and July, 2018. Field-testing of the compacted fill soil was conducted in accordance with ASTM D-
6938-08a (nuclear method). Results of the field-testing indicate that fill materials were compacted
to a minimum relative compaction of 90 percent (95 percent in pavement areas) of the laboratory
maximum dry density and at above the optimum moisture content as determined by test method
ASTM D-1557.
Tabulated results of the field compaction testing are provided in the attached Table I. Laboratory
determination of the reference compaction values for the fill materials are provided in Table II,
"Laboratory Test Results." Approximate field compaction test locations for the building pad are
shown on Figure 2.
4.0 ADDITIONAL CONSTRUCTION OBSERVATION
Any additional grading and backfilling should be observed and tested by CTE. However, prior to
any future development of the site, an appropriate updated geotechnical report should be completed.
\\ESC_SERVER\Projects\10-13000 to 10-13999 Projects\10-13583G\Rpt_As-Graded Final.doc
Final As-Graded Geotechnical Rep01i Page 3
Proposed Carlsbad Oaks North Business Park, Lot 17
Whiptail Loop, Carlsbad, California
December 26, 2018 CTE Job No. 10-135830
5 .0 CONCLUSIONS AND RECOMMENDATIONS
CTE concludes that the geotechnical aspects of the grading covered by this report are in general
conformance with the approved geotechnical report (Geocon, 2016) and the grading and
improvement plans (Project No. SDP16-04, Drawing No. 497-3A), additional geotechnical
documents provided during grading, and this final as-graded geotechnical report. Therefore, the
recommendations provided in the referenced report remain suitable for project design and
construction.
6.0 LIMITATIONS
The field evaluation, laboratory testing, and geotechnical analysis presented in this report have been
conducted according to current engineering practice and the standard of care exercised by reputable
geotechnical consultants performing similar tasks in this area. No other warranty, expressed or
implied, is made regarding the conclusions, recommendations and opinions expressed in this rep01i.
Variations may exist and conditions not observed or described herein may be encountered during
construction.
Even with the design and construction precautions provided, some post-construction soil movement
and associated distress should be anticipated. CTE's conclusions and recommendations are based on
an analysis of the observed conditions. If conditions different from those described in this repoti are
encountered, our office should be notified and additional recommendations, if required, will be
provided.
\\ESC _SERVER\Projects\ 10-13000 to 10-13999 Projects\! 0-l 3583G\Rpt_As-Graded Final.doc
Final As-Graded Geotechnical Repmi
Proposed Carlsbad Oaks North Business Park, Lot 17
Whiptail Loop, Carlsbad, California
December 26, 2018
REFERENCES
Summary of Compaction Testing for Retaining Wall
Proposed Carlsbad Oaks North Business Park, Lot 17
Whiptail Loop
Carlsbad, California
CTE Job No. 10-13583G, dated April 10, 2018
Certification of Building Pad Preparation
Proposed Carlsbad Oaks North Business Park, Lot 17
Whiptail Loop
Carlsbad, California
CTE Job No. 10-13583G, dated May 16, 2017
Update Geotechnical Report
Proposed Carlsbad Oaks North Business Park
Lot 17, Carlsbad, California
Geocon, Inc., Project No. 06442-32-21, dated March 26, 2016
Page 5
CTE Job No. 10-13583G
\\ESC _ SER VER\Projects\l 0-13000 to I 0-13999 Projects\ I 0-13583O\Rpt_As-Graded Final.doc
Job Name:
Job Address:
Date Test
No.
4/11/2017 1
4/11/2017 2
4/11/2017 3
4/11/2017 4
4/11 /2017 5
4/11 /2017 6
4/12/2017 7
4/12/2017 8
4/12/2017 9
4/12/2017 10
4/12/2017 11
4/12/2017 12
4/12/2017 13
4/12/2017 14
4/12/2017 15
4/12/2017 16
4/13/2017 17
4/13/2017 18
4/13/2017 19
4/13/2017 20
4/13/2017 21
4/13/2017 22
4/13/2017 23
4/13/2017 24
4/14/2017 25
4/14/2017 26
4/14/2017 27
4/14/2017 28
5/5/2017 29
5/5/2017 30
5/5/2017 31
5/5/2017 32
5/5/2017 33
5/5/2017 34
5/5/2017 35
5/5/2017 36
5/5/2017 37
5/5/2017 38
5/9/2017 39
5/9/2017 40
5/9/2017 41
5/9/2017 42
5/9/2017 43
5/9/2017 44
5/9/2017 45
5/9/2017 46
5/10/2017 47
TABLE I
COMPACTION TEST SUMMARY
Carlsbad Oaks North Business Park, Lot 17 Job No.
Lot 17, Whiptai l Loop Date:
Location Elevation Density
or Depth pcf
Feet
Loading Dock Footing (OX) N. of Bldg Pad 463.0 122.4
Loading Dock Footing (OX) N. of Bldg Pad 465.0 121.2
Loading Dock Footing (OX) N. of Bldg Pad 466.0 119.9
Loading Dock Footing (OX) N. of Bldg Pad 468.0 120.3
Loading Dock Footing (OX) N. of Bldg Pad 469.0 121 .5
Loading Dock Footing (OX) N. of Bldg Pad 471.0 120.9
Loading Dock Footing (OX) N. of Bldg Pad 464.0 118.6
Loading Dock Footing (OX) N. of Bldg Pad 465.0 118.5
Loading Dock Footing (OX) N. of Bldg Pad 467.0 119.6
Loading Dock Footing (OX) N. of Bldg Pad 463.0 119.2
Loading Dock Footing (OX) N . of Bldg Pad 468.0 117.7
Loading Dock Footing (OX) N . of Bldg Pad 470.0 118.2
Loading Dock Footing (OX) N. of Bldg Pad 463 .0 120.4
Loading Dock Footing (OX) N. of Bldg Pad 465 .0 119.7
Loading Dock Footing (OX) N. of Bldg Pad 467.0 118.9
Loading Dock Footing (OX) N. of Bldg Pad 469.0 120.2
Loading Dock Footing (OX) N. of Bldg Pad 471.0 123.7
Loading Dock Footing (OX) N. of Bldg Pad 463.0 124.1
Loading Dock Footing (OX) N. of Bldg Pad 465.0 123 .3
Loading Dock Footing (OX) N. of Bldg Pad 466.0 124.4
Loading Dock Footing (OX) N. of Bldg Pad 468.0 122.6
Loading Dock Footing (OX) N. of Bldg Pad 470.0 121.7
Loading Dock Footing (OX) N. of Bldg Pad 464.0 122.l
Loading Dock Footing (OX) N. of Bldg Pad 465.0 120.4
Loading Dock Footing (OX) N. of Bldg Pad 466.0 123.6
Loading Dock Footing (OX) N. of Bldg Pad 467.0 121.8
Loading Dock Footing (OX) N. of Bldg Pad 469.0 122.l
Loading Dock Footing (OX) N. of Bldg Pad 470.0 120.5
Proposed Bldg Pad 468.0 122.7
Proposed Bldg Pad 468.0 120.1
Proposed Bldg Pad 467.0 119.8
Proposed Bldg Pad 466.0 121.6
Proposed Bldg Pad 468.0 122.9
Proposed Bldg Pad 468.0 119.5
Proposed Bldg Pad 469.0 121.9
Proposed Bldg Pad 469.0 118.9
Proposed Bldg Pad 468.0 121.3
Proposed Bldg Pad 469.0 120.6
Proposed Bldg Pad 466.0 120.8
Proposed Bldg Pad 468.0 121.7
Proposed Bldg Pad 469.0 122.3
Proposed Bldg Pad 470.0 120.9
Proposed Bldg Pad 469.0 118.6
Proposed Bldg Pad 467.0 121.1
Proposed Bldg Pad 469.0 119.6
Proposed Bldg Pad 469.0 120.2
Proposed Bldg Pad 470.0 121 .8
** TEST FAILED, SEE RETEST
10-135830
11 /29/2018
Moisture Relative Soil
Content Compaction Type
%Dry %
Weight
10.2 94% 1
11.3 93% 1
11.1 92% 1
10.7 92% 1
10.5 93% 1
10.9 93% 1
10.6 91% 1
11.4 91% 1
11.2 92% 1
10.3 92% 1
10.9 90% 1
10.1 91% 1
10.2 93% 1
10.7 92% 1
11.3 91% 1
10.7 92% 1
10.3 95% 1
10.9 95% 1
11.1 95% 1
10.5 96% 1
10.6 94% 1
11.2 94% 1
10.6 94% 1
10.8 93% 1
11.4 95% 1
10.9 94% 1
11.3 94% 1
11.1 93% 1
10.6 94% 1
10.7 92% 1
11.1 92% 1
10.4 93% 1
10 .8 94% 1
11.5 92% 1
10.3 94% 1
11.7 91% 1
11.2 93% 1
10.8 93% 1
10.6 93% 1
10.3 94% 1
11.4 94% 1
10.8 93% 1
11.5 91% 1
11.1 93% 1
10.9 92% 1
10.6 92% 1
10.6 94% 1
TABLE I
COMP ACTION TEST SUMMARY
Job Name: Carlsbad Oaks North Business Park, Lot 17 Job No. 10-13583G
Job Address: Lot 17, Whiptail Loop Date: 11/29/2018
Date Test Location Elevation Density Moisture Relative Soi l
No. or Depth pcf Content Compaction Type
Feet %Dry %
Weight
5/10/2017 48 Proposed Bldg Pad 470.0 122.7 10.5 94% 1
5/10/2017 49 Proposed Bldg Pad 470.0 122.5 11.3 94% 1
5/10/2017 50 Proposed Bldg Pad 470.0 120.1 10.7 92% 1
5/10/2017 51 Proposed Bldg Pad 470.0 121.9 11.1 94% 1
5/10/2017 52 Proposed Bldg Pad 470.0 120.2 10.4 92% 1
5/10/2017 53 Proposed Bldg Pad 470.0 121.6 10.8 93% 1
5/10/2017 54 Proposed Bldg Pad 470.0 120.7 11.2 93% 1
5/12/2017 55 Proposed Bldg Pad FG 120.7 10.2 93% 1
5/12/2017 56 Proposed Bldg Pad FG 119.6 11.0 92% 1
5/12/2017 57 Proposed Bldg Pad FG 120.4 10.4 93% 1
5/12/2017 58 Proposed Bldg Pad FG 119.8 11.1 92% 1
5/12/2017 59 Proposed Bldg Pad FG 121.1 10.3 93% 1
5/12/2017 60 Proposed Bldg Pad FG 120.3 11.2 92% 1
5/12/2017 61 Proposed Bldg Pad FG 120.7 10.5 93% 1
5/18/2017 62 Parking Lot West of Bldg 468.0 121.1 10.6 93% 1
5/18/2017 63 Parking Lot West of Bldg 468.0 120.8 10.1 93% 1
5/18/2017 64 Parking Lot East of Bldg 468.0 124.1 10.8 95% 1
5/18/2017 65 Parking Lot East of Bldg 467.5 121.2 11.3 93% 1
5/18/2017 66 Parking Lot South of Bldg 468.0 120.7 10.2 93% 1
5/18/2017 67 Parking Lot South of Bldg 466.5 122.3 10.5 94% 1
5/18/2017 68 Parking Lot South of Bldg 467.0 123.6 11.7 95% 1
5/18/2017 69 Parking Lot South of Bldg 464.0 121.5 10.9 93% 1
5/18/2017 70 Parking Lot South of Bldg 465.5 122.4 10.6 94% 1
5/18/2017 71 Parking Lot South of Bldg 467.0 121.9 11.0 94% 1
2/1/2018 72 North Dock Walls SG 126.1 9.8 97% 1
2/1/2018 73 North Dock Walls SG 128.2 10.1 99% 1
2/1/2018 74 North Dock Walls SG 125.9 9.5 97% 1
2/1/2018 75 North Dock Walls SG 128.5 9.5 99% 1
2/1/2018 76 North Dock Walls SG 126.0 9.9 97% 1
2/1/2018 77 Nmth Dock Walls SG 126.7 9.6 97% 1
2/1/2018 78 Nmth Dock Walls SG 128.1 10.2 98% 1
2/1/2018 79 No1th Dock Walls SG 128.3 10.0 99% 1
2/20/2018 80 West Dock SG 127.3 9.5 98% 1
2/20/2018 81 East Dock SG 126.8 9.8 97% 1
2/20/2018 82 West Stairs SG 128.5 9.1 99% 1
2/20/2018 83 Center Stairs SG 128.1 9.0 98% 1
2/20/2018 84 East Stairs SG 128.7 9.3 99% 1
2/28/2018 85 West Stairs SG 128.0 9.6 98% 1
2/28/2018 86 Center Stairs SG 127.7 9.4 98% 1
2/28/2018 87 East Stairs SG 126.5 9.0 97% 1
3/14/2018 88 Northwest Parking Bays and Drive Areas SG 125.8 10.8 97% 1
3/14/2018 89 Northwest Parking Bays and Drive Areas SG 124.9 10.4 96% 1
3/14/2018 90 Northwest Parking Bays and Drive Areas SG 126.2 10.9 97% 1
3/14/2018 91 Northwest Parking Bays and Drive Areas SG 124.3 11.0 96% 1
3/14/2018 92 Northwest Parking Bays and Drive Areas SG 125.5 10.3 96% 1
3/14/2018 93 Nmthwest Parking Bays and Drive Areas SG 123.9 10.2 95% 1
3/14/2018 94 Northwest Parking Bays and Drive Areas SG 126.1 10.6 97% 1
** TEST FAILED, SEE RETEST 2
TABLE I
COMP ACTION TEST SUMMARY
Job Name: Carlsbad Oaks North Business Park, Lot 17 Job No. 10-135830
Job Address: Lot 17, Whiptail Loop Date: 11/29/2018
Date Test Location Elevation Density Moisture Relative Soil
No. or Depth pcf Content Compaction Type
Feet %D1y %
Weight
3/26/2018 95 Fire Lane/North SG 126.7 10.4 97% 1
3/26/201 8 96 Fire Lane/NE SG 126.3 10.3 97% 1
3/26/201 8 97 Fire Lane/SE SG 125.5 11.0 96% 1
3/26/2018 98 Fire Lane/South SG 126.2 10.4 97% 1
3/26/201 8 99 Fire Lane/SW SG 128.1 10.2 98% 1
3/26/2018 100 Fire Lane/SW SG 125 .6 10.7 97% 1
3/26/2018 101 Fire Lane/West SG 125.1 10.l 96% 1
3/26/2018 102 Fire Lane/NW SG 126.5 10.5 97% 1
3/26/2018 103 Fire Lane/NW SG 126.0 10.8 97% 1
4/4/2018 104 Front Drive Area SG 126.2 9.0 97% 1
4/4/201 8 105 Front Drive Area SG 127.0 9.3 98% 1
4/4/2018 106 Front Drive Area SG 128.3 9.3 99% 1
4/4/2018 107 Front Drive Area SG 128.0 9.5 98% 1
4/4/2018 108 Front Drive Area SG 127.6 9.2 98% 1
4/4/2018 109 Front Drive Area SG 129.0 9.4 99% 1
4/4/2018 11 0 Front Drive Area SG 128.6 9.5 99% 1
4/4/2018 111 Front Drive Area SG 127.1 9.5 98% 1
5/14/201 8 11 2 West Dock SG 124.7 9.0 96% 1
6/4/2018 113 SG Below Proposed Pavement NW Comer of Site FSG 125.3 9.9 96% 1
6/4/2018 114 SG Below Proposed Pavement NW Corner of Site FSG 127.2 10.1 98% 1
6/4/2018 11 5 SG Below Proposed Pavement NW Comer of Site FSG 126.6 10.3 97% 1
6/7/2018 11 6 SE PCC Paving SG 127.2 10.4 98% 1
6/7/201 8 117 SE PCC Pavin g SG 125 .9 11.2 97% 1
6/7/2018 118 South PCC Paving SG 125.2 10.4 96% 1
6/7/2018 119 SW PCC Paving SG 124.8 10.7 96% 1
6/7/2018 120 SW PCC Paving SG 125.2 10.3 96% 1
6/13/2018 121 Parking Bays & Drive Areas W Side of Bldg SG 123.9 10.6 95% 1
6/13/201 8 122 Parking Bays & Drive Areas W Side of Bldg SG 125.4 10.2 96% 1
6/13/2018 123 Parking Bays & Drive Areas W Side of Bldg SG 124.3 10.4 96% 1
6/13/2018 124 Parking Bays & Drive Areas W Side of Bldg SG 126.1 11.0 97% 1
6/13/2018 125 Parking Bays & Drive Areas W Side of Bldg SG 125.8 10.8 97% 1
6/13/2018 126 Parking Bays & Drive Areas W Side of Bldg SG 126.6 10.9 97% 1
6/19/2018 127 Front Drive Area SG 123.7 9.0 95% 1
6/19/201 8 128 Front Drive Area SG 127.1 9.4 98% 1
6/19/2018 129 Front Drive Area SG 129.8 8.4 100% 1
6/19/2018 130 Front Drive Area SG 129.0 8.7 99% 1
6/19/2018 13 1 Front Drive Area SG 127.0 9.1 98% 1
6/19/2018 132 Front Drive Area SG 128.5 9.0 99% 1
6/19/2018 133 Front Drive Area SG 125.6 8.9 97% 1
6/19/2018 134 Front Drive Area SG 127.3 9.4 98% 1
6/19/2018 135 Front Drive Area SG 127.9 9.2 98% 1
7/3/2018 136 North Sidewalk SG 124.7 9.8 96% 1
7/3/2018 137 South Driveway Corner Sidewalk SG 126.1 9.6 97% 1
7/3/2018 138 Sidewalk South of Driveway SG 125.8 9.3 97% 1
7/3/201 8 139 Sidewalk South of Driveway SG 128.7 9.0 99% 1
7/3/2018 140 Sidewalk South of Driveway SG 125 .2 9.7 96% 1
7/3/2018 141 Driveway Repair Base 136.5 6.1 98% 2
** TEST FAILED, SEE RETEST 3
TABLE IA
COMP ACTION TEST SUMMARY
Job Name: Carlsbad Oaks North Business Park, Lot 17-Electrical Trench Job No. 10-13583G
Job Address: Lot 17, Whiptail Loop Date: 11/29/2018
Date Test Location Elevation Density Moisture Relative Soil
No. or Depth pcf Content Compaction Type
Feet %Dry %
Weight
6/30/2017 EL-1 2" Electrical Trench on Bldg Pad 469.0 120.7 10.3 93% 1
6/30/2017 EL-2 2" Electrical Trench on Bldg Pad 470.0 121.6 11.9 93% 1
6/30/2017 EL-3 2" Electrical Trench on Bldg Pad 469.0 120.8 11.1 93% . 1
6/30/2017 EL-4 2" Electrical Trench on Bldg Pad 470.0 122.9 10.6 94% 1
7/10/2017 EL-5 Electrical Trench on Bldg Pad 467.0 124.1 10.6 95% 1
7/10/2017 EL-6 Electrical Trench on Bldg Pad 468.0 119.6 9.9 92% 1
7/10/2017 EL-7 Electrical Trench on Bldg Pad 469.0 123.3 10.5 95% 1
7/10/2017 EL-8 Electrical Trench on Bldg Pad 470.0 120.9 10.6 93% 1
8/2/2017 EL-9 Secondary Power West of Bldg 67.0 122.7 11.4 94% 1
8/2/2017 EL-10 Secondary Power West of Bldg 68.0 122.9 11.1 94% 1
8/2/2017 EL-11 Secondary Power West of Bldg 69.0 124.6 10.3 96% 1
8/2/2017 EL-12 Primmy Power West of Bldg 66.0 123.8 10.7 95% 1
8/2/2017 EL-13 Primary Power West of Bldg 67.0 123.9 10.3 95% 1
8/2/2017 EL-14 Primmy Power West of Bldg 69.0 123.5 10.9 95% 1
8/2/2017 EL-15 Telecom Trench West of Bldg 67.0 121.3 11.2 93% 1
8/2/2017 EL-16 Telecom Trench West of Bldg 69.0 123.6 10.6 95% 1
** TEST FAILED, SEE RETEST 4
TABLEIB
COMP ACTION TEST SUMMARY
Job Name: Carlsbad Oaks North Business Park, Lot 17-Storm Drain Job No. 10-135830
Job Address: Lot 17, Whiptail Loop Date: 11 /29/2018
Date Test Location Elevation Density Moisture Relative Soil
No. or Depth pcf Content Compaction Type
Feet %Dry %
Weight
8/12/2017 SD-1 Storm Drain SG 126.7 10.2 97% 1
8/12/2017 SD-2 Storm Drain SG 124.1 9.7 95% 1
8/12/2017 SD-3 Storm Drain SG 125.0 9.3 96% 1
8/12/2017 SD-4 Storm Drain SG 128.3 10.0 99% 1
8/12/2017 SD-5 Storm Drain SG 127.6 9.8 98% 1
8/12/2017 SD-6 Storm Drain SG 125.2 9.5 96% 1
8/24/2017 SD-7 Storm Drain SG 124.0 10.4 95% 1
8/24/2017 SD-8 Storm Drain SG 126.8 10.2 97% 1
8/24/2017 SD-9 Storm Drain SG 124.7 10.5 96% 1
8/24/2017 SD-10 Storm Drain SG 126.1 10.2 97% 1
11/14/2017 SD-11 8" Storm Drain West of Bldg FSG 119.7 9.3 92% 1
11/14/2017 SD-12 8" Storm Drain West of Bldg FSG 120.5 10.9 93% 1
11/14/2017 SD-13 18" Stmm Drain West of Bldg FSG 118.2 10.3 91% 1
11/14/2017 SD-14 18" Storm Drain West of Bldg FSG 119.4 9.9 92% 1
11/14/2017 SD-15 18" Storm Drain West ofBldg FSG 118.0 10.2 91% 1
** TEST FAILED, SEE RETEST 5
TABLEIC
COMP ACTION TEST SUMMARY
Job Name: Carlsbad Oaks North Business Park, Lot 17-Sewer Job No. 10-135830
Job Address: Lot 17, Whiptail Loop Date: 11/29/2018
Date Test Location Elevation Density Moisture Relative Soil
No. or Depth pcf Content Compaction Type
Feet %Dry %
Weight
9/1/2017 S-1 Sewer Line Trench SW Pait of Site -4.0 118.6 11.6 91% 1
9/1/2017 S-2 Sewer Line Trench SW Part of Site -3.0 122.3 11.0 94% 1
9/1/2017 S-3 Sewer Line Trench SW Part of Site -2.0 120.5 10.9 93% 1
9/1/2017 S-4 Sewer Line Trench SW Part of Site FG 119.9 10.5 92% 1
** TEST FAILED, SEE RETEST 6
TABLE ID
COMP ACTION TEST SUMMARY
Job Name: Carlsbad Oaks North Business Park, Lot 17-Fire Lanes Job No. 10-135830
Job Address: Lot 17, Whiptail Loop Date: 11 /29/2018
Date Test Location Elevation Density Moisture Relative Soil
No. or Depth pcf Content Compaction Type
Feet %Dry %
Weight
9/2/2017 F-1 Fire Lane SG 123.8 10.3 95% 1
9/2/2017 F-2 Fire Lane SG 124.8 10.1 96% 1
9/2/201 7 F-3 Fire Lane SG 124.0 10.0 95% 1
9/2/2017 F-4 Fire Lane SG 125.5 10.2 96% 1
** TEST FAILED, SEE RETEST 7
TABLE IE
COMP ACTION TEST SUMMARY
Job Name: Carlsbad Oaks North Business Park, Lot 17-Water Lines Job No. 10-13583G
Job Address: Lot 17, Whiptail Loop Date: 11/29/2018
Date Test Location Elevation Density Moisture Relative Soi l
No. or Depth pcf Content Compaction Type
Feet %Dry %
Weight
12/13/2017 W-1 Water-Fire Line SG 126.7 8.4 97% 1
12/13/2017 W-2 Water-Fire Line SG 124.5 8.2 96% 1
12/13/2017 W-3 Water-Fire Line SG 124.1 8.3 95% 1
12/13/2017 W-4 Water-Fire Line SG 123.8 8.0 95% 1
12/13/2017 W-5 Water-Fire Line SG 122.9 8.6 94% 1
** TEST FAILED, SEE RETEST 8
TABLE IF
COMP ACTION TEST SUMMARY
Job Name: Carlsbad Oaks North Business Park, Lot 17-Retaining Walls Job No. 10-13583G
Job Address: Lot 17, Whiptail Loop Date: 11/29/2018
Date Test Location Elevation Density Moisture Relative Soil
No. or Depth pcf Content Compaction Type
Feet %Dry %
Weight
3/28/2018 RW-1 Wall 2 Station 10+10 475.0 121.4 11.2 93% 1
3/28/2018 RW-2 Wall 2 Station 10+50 473.0 120 .8 10.3 93% 1
3/28/2018 RW-3 Wall 2 Station 11 +00 473.0 120.4 10.5 93% 1
3/28/2018 RW-4 Wall 2 Station 11 +50 475.0 123.1 10.7 95% 1
3/28/2018 RW-5 Wall 2 Station 10+50 474.0 119.8 10.3 92% 1
3/28/2018 RW-6 Wall 2 Station 12+90 473.0 124.0 10.2 95% 1
3/29/2018 RW-7 Wall 2 Station 10+30 477.0 118.6 11.0 91% 1
3/29/2018 RW-8 Wall 2 Station 10+90 475.0 119.3 10.5 92% 1
3/29/2018 RW-9 Wall 2 Station 11+40 475.0 117.5 10.9 90% 1
3/29/2018 RW-H Wall 2 Station 12+00 476.0 119.8 10.3 92% 1
3/29/2018 RW-11 Wall 2 Station 12+70 474.0 121.4 10.4 93% 1
3/29/2018 RW-L Wall 2 Station 13+50 475.0 118.2 10.4 91% 1
3/29/2018 RW-1 Wall 2 Station 14+50 473 .0 117.7 10.6 90% 1
3/29/2018 RW-1 , Wall 2 Station 15+30 473.0 121.1 10.7 93% 1
3/30/2018 RW-1' Wall 2 Station 11 +70 476.0 121.4 10.7 93% 1
3/30/2018 RW-H Wall 2 Station 12+20 477.0 118.1 10.6 91% 1
3/30/2018 RW-1 Wall 2 Station 13+20 477.0 117.4 10.3 90% 1
3/30/2018 RW-1! Wall 2 Station 14+00 475.0 118.2 11.4 91% 1
3/30/2018 RW-lc Wall 2 Station 14+40 477.0 121.5 11.0 93% 1
3/30/2018 RW-2( Wall 2 Station 15+00 475.0 120.6 10.8 93% 1
3/30/2018 IRW-21 Wall 2 Station 14+40 477.0 118.3 10.7 91% 1
** TEST FAILED, SEE RETEST 9
Job Name:
Job Address:
Sample No.
TABLE II
LABORATORY TEST DATA
Carlsbad Oaks North Business Park, Lot 17 Job No. 10-13583G
Lot 17, Whiptail Loop Date 11/29/2018
Maximum Optimum
Dry Density Moisture Soil
pcf Content Description
%wt
130.1 8.1 Moderate brown DG