Loading...
HomeMy WebLinkAboutDWG 326-4L; CT 90-34; AVIARA PA 27; 01-14PLANS FOR THE IRRIGATIO AND PLANTING OF: AVIARA-CT 90-34 • GENERAL NOTES: 1. THE CONTRACTOR MUST NOTIFY THE CITY PLAN CHECK CONSUL TANT (619) 438-11621, EXTENSION #422-1, 72 HOURS (THREE WORKING DAYS), PRIOR TO STARTING CONSTRUCTION. 2. THE LANDSCAPE OR IRRIGATION CONTRACTOR IS TO VERIFY EXISTING P.S.I. AT JOB SITE PRIOR TO INSTALLING LANDSCAPE IRRIGATION SYSTEM. VERIFICATION SHALL BE MADE WITH THE APPROPRIATE WATER DISTRICT. 3. ALL REDUCED PRESSURE 8ACKFLOW PREVENTERS SHALL BE TESTED AFTER INSTALLATION, RELOCATION, OR REPAIRS BY A CITY APPROVED CERTIFIED TESTER. CALL 438-0218 FOR A LIST OF CITY APPROVED CERTIFIED TESTERS. DEVELOPER/OWNER IS RESPONSIBLE FOR SUPPLYING A COPY OF THE TEST RESULTS TO THE CITY DEPARTMENT OF UTILITIES AND MAINTENAl'ICE, 405 OAK STREET. 4. CONSTRUCTION SCHEDULE: A. PRIOR TO ISSUANCE OF GRADING PERMITS, THE APPLICANT OR APPLICANT'S AGENT SHALL OBTAIN CITY APPROVAL OF A CONSTRUCTION SCHEDULE AND/OR EXHIBIT OUTLINING THE TIMING OF THE SLOPE PLANTING AND IRRIGATION. B. SPECIAL CONSIDERATION SHALL BE GIVEN TO WATER AND ELECTRICAL SERVICES. C. IRRIGATION AND PLANTING SHALL TAKE PLACE AS GRADING PROGRESSES. D. THE SCHl;';DULE SHALL SHOW TIMING OF CONSTRUCTION OF FREE-STANDll'IG, RETAINING AND CRIB WALLS IMMEDIATELY AFTER ROUGH GRADING AT EACH LOCATION IS ACHIEVED. S. IRRIGATION: A. INSTALLATION OF IRRIGATION AS SHOWN ON THE APPROVED PLANS SHALL COMMENCE WJTHIN 10 DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED GRADING PLANS. 6. PLANTING: A. PLANTING AND IRRIGATION FOR THE AREAS DESCRIBED ABOVE SHALL BE COMPlETELY li'ISTALLED, AS SHOWN ON THE APPROVED PLANS, WITHIN 30 DAYS AFTER THE IRRIGATION INSTALLATION FIRST COMMENCES. 7. SLOPE PLANTING STANDARDS AND APPLICATION: A. JUT\: MATTING ON SLOPES SHALL BE REQUIRED WHEN PLANTING OCCURS BETWEEN AUGUST 15 AND APRIL 15. B. SLOPES 3 FE!cT OR LESS IN VERTICAL HEIGHT AND ADJACENT TO PUBLIC WALKS OR STREETS REQUIRE A MINIMUM STANDARD #1 (COVER CROP A..l':L[! JUT ED). C. SLOPES 4 FEET TO 8 FEET IN VERTICAl HEIGHT REQUIRE STANDARDS #1 (COVER CROP/JUTE MESH), #2 (GROUND COVER) AND #3 (LOW SHRUBS). D. SlOPES IN EXCESS OF 6 FEET IN VERTICAL HEIGHT REQUIRE STANDARDS #1 (COVER CROP/JUTE MESH), 112 (GROUND COVER), #3 (LOW SHRUBS), AND #4 (TREES ANO LARGE SHRUBS). DECLARATION OF RESPONSIBLE CHARGE I HEREBY DECLARE THAT I AM THE LICENSED DESIGNER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONAL CODE, AND THAT' THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BV THE CITY OF CARLSBAD IS CONFINED TO REVIEW ONL V AND DOES NOT RELIEVE ME AS THE LICENSED DESIGNER OF WORK OF MV RESPONSIBILITIES FOR PROJECT DESIGN. THESE PLANS HAVE BEEN PREPARED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED LANDSCAPE CONCEPT PLAN, WATER CONSERVATION PLAN, FIRE PROTECTION PLAN, AND ALL CONDITIONS OF APPROV RELATED TO ANDSCAPING. DATE: &>/2j /qq._ ' i j --- ··•'-'.'t-U ' . '7<'.) L✓• ' ~ .· .~ ··- PHASE II BLOW-UP 'f=======~CAQLQ::,A[)l'R AYlARA Pi-IP-SE TI fF'--D.JECT SITE==, 'fDI tttTl7 A-lJ.N OCEANSIDE ------------------------------------------------------I ---------------~ PROJECT LOCATION MAP N.T.S. 18 -f'-..:--=.-------~ 11\S~ . . ' ENCINITAS ,) VICINITY MAP Fourth Avenu11 Corporate Centor 1551 Fourth Avaooe/Sutta ~ SO.n OleQo, CA92101 C619) 239-2450/fl>J( 239-0107 Londscapo -• Plarring I I I ~-_..--IRRIGATION SHEET NO. ~----PLANTING SHEET NO. SHEET INDEX SHEET NO. TITLE SHEET 1 IRRIGATION PLANS IRRIGATION SPECIFICATIONS IRRIGATION LEGEND & NOTES IRRIGATION DETAILS PLANTING PLANS 2-3 4-5 6 PLANTING SPECIFICATIONS PLANTING LEGEND & DETAILS 7-8 9-10 11 -13 14 GENERAL NOTES CONT. E. TEMPORARY/SPECIAL CONDITIONS: AREAS GRADED FLATTER THAN 6:1 REQUIRE STAl'IDARD #1 (COVER CROP) WHEN THEY HAVE ONE OR MORE OF THE FOLLOWING CONDITIONS: 1 ) 2) 3) SHEET GRADED PADS NOT SCHEDULED FOR IMPROVEMENTS WITHIN 6 MONTHS OF COMPLETION OF ROUGH GRADING. A POTENTIAL EROSION PROBLEM AS DETERMINED BY THE CITY. IDENTIFIED BY THE CITY AS HIGHLY VISJBlE AREAS TO THE PUBLIC OR HAVE SPECIAL CONDITIONS THAT WARRANT IMMEDIATE TREATMENT. F. AREAS TO BE HYDROSEEDEO SHAlL FIRST BE DISKED OR ROTOTILLED TO PROVIDE A FRIABLE, LOOSE SEED BED. 8. SLOPE IRRIGATION STANDARDS A. WATER SERVICE (POINT OF CONNECTION) INSTALLATION, TEMPORARY OR PERMANENT, SHALL BE IN PLACE TO COINCIDE WITH PlANTING TIMING SPECIFIED IN SECTION E.3-1. 9. LETTER OF CERTIFICATION (INSTALLATION): A. THE LICENSED DESIGNER OF RECORD FOR ALL THE PROJECTS REQUIRING LANDSCAPE PLANS SHALL SUBMIT A LETTER TO THE CITY STATING THAT THE PROJECT HAS BEEN INSTALLED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS. 10. AS-BUILT$: A. PRIOR TO RELEASE OF BONDS, AS-BUil T LANDSCAPE PLANS FOR THE BONDED WORK SHALL BE SUBMITTED TO AND APPROVED BY THE CITY. B, AS-BUILT PLANS SHALL BE DRAFTED ClEARLY TO THE SATISFACTION OF THE CITY, AND THE ORIGINAL MYLARS SHALL BE SUBMITTED TO THE CITY FOR THEIR KEEPING. 11. A REPRESENTATIVE OF CITY OF CARLSBAD PLANNING DEPARTMENT SHALL BE PRESENT, ALONG WITH LANDSCAPE ARCHITECT, TO MARK THE TREES THAT ARE TO BE SAVED ON AVIARA PHASE II. i\PPF(O \1ED FO }1 PLl\NTING .-'\KD IRRIGATION ONLY, INCIJUDING PR1~CISE LOC1\TION OF' PLANTING .4-REl\S_ "AS BUil T" RCE ___ EXP. ___ _ REVlEWE:O BY: INSPECTOR .-------,---t----------,------------l----4-------4----+--___. ~ CIT)' 0 r' CARLS BAD Ll__J PLANNING OEPARTME.NT ... DATE DATE ; LANDSCAPE IMPROVEMENTS FOR: PLANNING AREA 2 7 t---t--t----------------+----l-'---+---+-----1 t'E2-"='1--t7 IA R ASE 11 7-2 ASSIST r--=;;c-r;;;;-;:;-;-;--t-----------------:---+---l-------1 ·01-,1-1 BY; __ _ DATE l'lrTIA.L ~AT!' IN,TIA.L DAIT · INITl<J. REVISION DESC.RIPTION C''.i<D BY, -OTl-<LP A"?~~ c,,Y ~PROV~L. '<VWO BY: ENCi"= if. WOR~ I -PROJECT NO. ±J DR,\V.INS "IL'. --.CT .. 9D::-..34-.32w-4-l----. ~ ,. '·T_ " - ! I I i I I! 'I 'I I I 'I '' '' I I SEELANDSCAPEIMPROVEMENT----11-'----+----L..1 DRAWINGS FOR CARLSBAD TRACT \. NO. 89·37 AVIARA PHASE 11 FOR 1 '' EXISTING IRRIGATION SYSTEM -SEE SHEET 9 DRAWING NUMBER 318·9L I ' ' I ' \ \ \ I ' ',, \ '' \\ I I ', I \\ \ I I I \ \ \ \ \ I ' I _I. \ I IJ) 0 \ \ \ I \ u r I ' - ------------,---~---~------,-,--~----:l::,r.~4~:-:c, ' \ NOTE: -~--_...lr\-~ IRRIGATION MAINLINE FOR ALL-/, () T ' 06:534\uJ 40' RESIDENTIAL LOTS SHALL BE 1'..'. SCHEDULE 40 PVC. WATER METER SHALL BE 3/4" SIZE BACKFLOW PREVENTER AND PRESSURE REGULATOR SHALL BE .l'.'. SIZE W PRESSURE REGULATOR SET @ 75 PSI (-sr=e t::efA//.--LI S/-tT.E;;>J (Av,AI~ srJ<nc 'f'?Po-Su~ l:S 125 P"S.l J \ -------1 {' I /·•,o· I I I I LOT ,/ .r I.. ,, ") p, ,. ' I,UF ·-' '-I>-'i> I I {,, I • I I I \ 1 n \ (I "/ 1 \_ ' ' ' I ----- l ' I I /,()'/' (i '• :~ "-: \ 1/ (/ / ( LOT :34 56 C ·;, --- LO'/' 34 \(',. \ \,, . 1/ 1/ /,OT ? cl I b (' 't \ \ '. / / ,'j,'3 I ' I I :t \ \ ' 1\ \\ -~ \\ I I I \ 1 \-·. \ I \ \ / \ \ \ \ I\ \' \'-, . .:., ,\ \ \ \' \\ I I I I \ I \ '\ \ \ I \ I \, I \ \\ . " \ \ \ ,I ' \ \\ \ I\ \ I I i.Ci·, ,,. _,,.i.:·_ • <~ !,OT 32 1/ /,OT I! / / 1 ' I ' ______ SEE LANDSCAPE IMPROVEMENT --------------t-~ DRAWINGS FOR CARLSBAD TRACT _ _.-------------NO. 89-37 AVIARA PHASE II FOR __..--EXISTING IRRIGATION SYSTEM ;'-- ' "'---I I I I ·\··._ I I . O:··, I , i r \ I -c'. _/;,~, ,, -, ' \ \ I I '-,,,_ "' ~:;: ,. '.,., ,, -• ' .... SEE SHEET__!!_ DRAWING NUMBER 318·9L .Y-"'i;., '-,,,_ '-,,,_ r :">('\ 4: \ \ /\ I ' I I \ ' I ' I \ \ \ Fourth Avenue Corporate Center 7 551 Fourth Avenue/Suite 200 San Diego, CA92101 {619) 239-2450/FAX 239·0107 --/fg/ ~o 32 \ I I I APPHOVED ' I \ \ I . ' ' ENGINEERING PLANCHECKER nArr l~lllAI :-1-: . .,,. _-. . I DATE I I I / I / / I I / / / O' ----40' IF EXISTING IRRIGATION EQUIPMENT (IE; SPRINKLER HEADS, PIPE, VALVES, ETC.) IS DAMAGED BY GRADING OR BY OTHER CONSTRUCTION IMPROVEMENTS· THIS CONTRACTOR SHALL REPAIR OR REPLACE AT NO EXTRA COST TO THE OWNER ANY DAMAGED EQUIPMENT TO THE SATISFACTION OF THE LANDSCAPE ARCHITECT AND OWNER. 80' 120' GRAPHIC SCALE: 1" ~40' /1.l7 .l)F?CJ\1ED F'0}1 })l,!\N'T'INC; 1\NI) JF(FzIG1t'I'JOi\J ONI.'{, INCLlJfJINC: P"R"FCTS~ LO C/\rJ'IO K O }' I)LA_NrrING .4.I-1EA.S. IRRIGATION PLAN II AS BUILT" RU L X r', DATE R[Vl[wlD BY 'NSPECHJR DATE ----------------------+-----+----~----l c1TY oF ·cARLSBAITT Sl,EETS PLANNING DEPARTMENT ~j 4 -------------------------------------------- APPR -- DA TE INITIAL )A-E INITIAL --·--·--·-.. ·-·--·----_,_,, _____ . ------·------·-·-----··-----·---·-- LANDSCAPE IMPROVEMENTS FOR: PLANNING AREA 27 -~IARA PHASE II . % . - REVISION DESCRIPTION nHH"R A~PRnVAI CITY APPROVAL ~ SEE LANDSCAPE IMPROVEMENT_,,~- DRAWINGS FOR CARLSBAD TRACT NO. 89-37 AVIARA PHASE II FOR EXISTING IRRIGATION SY.STEM SEE SHEET /0 DRAWING NUMBER 318-9L (,\106594\G4 j_"" ::: 40' \ \ \ \ \ \ \ \ \ -----\ \ 0 ' V'> \ WATER METER SHALL BE~ SIZE· BACKFLOW PREVENTER AND PRESSURE REGULATOR SHALL BE 1: SIZE W PRESSURE REGULATOR SET @75 PSI (~te:r.t-.1L1 l-~ SITT.&) I.OJ 10 {j,.,.;~ L-J,..:ft,l..E :::, TP-<r\C, ,~'&..,\r<E I'S \,',2ro \4~'f:'S 1J ., \ \\ \ ' ' I \ I \ \ \ \ ' ' ', I ' / ,. \• 1 I '\ . \ 1X... .. · 1· / •✓ \ \ i I I I I -I I ,,.,~, \!, -r >-· . \ i , ' ' I I, ', I' ' I I 'I ' \ I, I\ ', i I , '; I ,I \ I \ \ Ci] · ·· I I I ' • I I I ' I, ' ' . ' 1 / / ii ,-_) '(' . • . • • . • / ••.I • . . • • I.OT 26' ) i ' r' I . ~. . ·• . •• i ' t \ • '< , 0· \.. \ / . . . l '- !UT :;: I,, ,, 65 1 / ·-~ ---. ',, \ ,. I /" ,: . • • . !, U I .... ---- • . . . , .. . . I \ ' ,J > / rF I • • ..... ' / I ' I ' \ I I ' ' I -, 1' . : ( , (.11\ / l', ' ~ • • . . \ ·'-1 •·, ' \ I I I \ I I \ \ ; ' I 1--······--- Key Map NOTE: IF EXISTING IRRIGATION EQUIPMENT (IE; SPRINKLER HEADS, PIPE, VALVES, ETC.) IS DAMAGED BY GRADING OR BY OTHER CONSTRUCTION IMPROVEMENTS; THIS CONTRACTOR SHALL REPAIR OR REPLACE AT NO EXTRA COST TO THE OWNER ANY DAMAGED EQUIPMENT TO THE SATISFACTION OF THE LANDSCAPE ARCHITECT ANDOWNER . _\ -elf', i ,' ~-~-:c-,-ii:/'~ // \, i \ •~-Nj.Y // , "•., ./ .. ; / Fourth Avenue Corporate Center APr0 ROVED C:NGINE:C:rilNG PLANCHECKU1 DATE O' 40' 80' 120· GRAPHIC SCALE: 1" =40' .A[] !) Fe C) \TC D ? 0 I< r) L A.J'~ ~r IN c~ /\.N JJ IRRI c; .4.'f JC) N INCIJUIJING 0 Kl//, PRf<_:c:ISF~ P.L1-\N'TING ·1· (_·1 c··, 11 'I, ·1· 0 N __ J ; _, .c~. , . -. l IRRIGATION PLAN HAS BUIL T0 RC:: -·--·-·· F.XP DAil REVl[w[J BY l'ISPECl □R JATE 0-------,f----+-·--·--·-. ··--· -.. -.. -------·---·-----.--._-_ -....... -... _-__ :_--_-_· __,--:-=--=--=--=--=--=--=.'=--=--=--=,:-=--=-: ~ CITJAN~~ ~fr~~N~AD u!] 0-------,f----+----.. -· ------·-----····-- LANDSCAPE IMPROVEMEN'TS FOR: PLANNING AREA 27 A VIARA PHASE II 1551 Fourth A'w'enue/Suite 200 o-------,f----+--·---·-· ·----------·-·--···---APP San Diego, CA 92101 (619) 239·2450/FAX 239·0107 I----. --·-- Landscape Archrlecture • Planning -/f 9/---o 32 CAH 1N:11A1 f:NCINH.R OF 'N'J,;.,_K ··-·-·--·--------.. ····--------+--------+----+-- -··-···-··-··•---+---------- DATE : I~ TIAL REVISION DESCRIPTION OTH[R APPROVAL C TY APPROVAL ASSI L'.: l)~W~N~3~Y~--~~--P-R_O_J_tc_r_N_0_._~13D~,~~AN? CHKLJ 8Y GT 90-34 ,<.lp ~ RV\JD 3Y, t.A ..i£S.a.6~Ut:"111Hl ., __ ·-..... ,.-~·---. -.,: =-•, -·1 ~, -u -- SEC710N 02441 IBllli,ATJQ!iBY.SlliM PAB.U -GENERAL 1 1 SCOPE: THE WORK INCLUDES ALL SERVICES, LABOR, MATERIALS, TRANSf'ORTATION AND EQUIPMENT NECESSARY TO PERFORM THE WORK INDICATED ON THE DRAWINGS AND AS SPECIFIED. OWNER/DEVELOPMENT WILL OBTAIN AND PAY ALL PERMITS RFOUIRED BY GOVERNING AUTHORITIES. AU ON SITE. RECLAIMED WATER PIPING SHALL BE INST AlLED IN ACCORDANCE WITIJ THE UNIFORM PLUMBING CODE AND ALL OTHER LOCAL GOVERNING CODES, RULES, AND REGULATION. ALL PIPING SHALL BE CONTINUOUSLY AND PERMANENTLY MARKED WITH THI: MANUFACTURER'S NAME OR TRADEMAR~. NOMINAL SIZE, AND SCHEDULE OR CLASS INDICATING Tl IE PRESSURE RATING. THE GENERAi_ CONDiTIONS AND DIVISION 1 APPLY TO THIS SECTION AS FULLY AS IF REPEATED HEREIN. PERMITS AND I ICENSES UNLESS OTHERWISE STATED. SECURE THE REQUIRED LICENSES AND PERMITS INCLUDING PAYMENTS OF CHARGES AND FEES, GIVE Rl:QUIRED NOTICES TO PUBLIC AUTHORITIES, AND VERIFY PERMI1S SE:CUREO OR ARRANGc:MENTS MADE BY OTHERS AFFECTING THE WORK OF THIS SECTION. WATER METERS AND POWER METERS WILL BE THE RESPONSIBlclTY OF THE OWNER AND /OR HIS REPRE'SENTATIVE FOR INSTALLATION ANO PERMIT FEES. 1 .1 .1 _1 2 1 1 1.2 1 2.. .1 .2 RELATED WORK LANDSCAPING SECTION 02480 COMPLIANCE TO CITY OF CARLSBAD POTABLE WATER STANDARDS OUAl IIY ASSURANCE OUAI IFICATIONS OF INSTAI LERS PROVIDE AT LEAST ONE PERSON WHO SHALL BE PRESENT AT ALL TIMES DURING EXECUTION OF THIS PORTION OF THE WORK AND WHO SHALL BE THOROUGHLY FAMILIAR WITH THE TYPE OF MATERIALS BEING INSTALLED, THE MATERIA!_ MANUFACTURE'S RECOMMENDED METHODS OF INSTALLATION, TIJE CITY 01' c_ARLSBAD POTABLE WATER STANDARDS AND WHO SHALL DIRECT All WORI( PERFORMED UNDER THIS SECTIDN CODES AND STA"lDARDS IN ADDITION TO COMPLYING WITH ALL PERTINENT CODES AND REGULATIONS, COMPLY WITH THE LATEST RULES OF THE STATE OF CALIFORNIA, DIVISIONS oc INDUSTRIAL SAFETY. FOR ALL MATERIALS. REFER TO THE LATEST EDrTION OF THI: GREEN BOOK STANDARD SPE'CICICATIONS FOR PUBLIC WORKS CONSTRUCTlotJ WHERE APPLICABLE. THE..cJ.TY OF CARLSBAD POTABLE WATER STANDARDS, LATEST EDITIONS AND RULES AND REGULATION FOR POTABLE WATER SERVICE l!J THE CITY OF CARLSBAD LATEST EDITIONS ARE INCORPORATED UNTO THESE SPECIFICATIONS BY REFERENCE WHERE POTABLE WATER IS PROPOSED. SUBMITTALS 1 SUBMIT COMPLETE MATERIAL LIST PRIOR TO PERFORMING ANY WORK SU8Ml1 CATALOG DATA ANJ FUU_ DESCRIPTIVE LITERATURE WHENEVER THE USE OF ITEMS DIFFEREl-,'T THAJ-.: THOSE SPECIFIED IS REQUESTED SUBfllT NOTARIZED CERTIFICATES BY PLASTIC PIPE AND FITTING MANUFACTURERS INDICATING THAT MATERIAL COMPLIES WITH SPECIFICATIONS, UNLESS MATERIAL HAS BEEN PREVIOUSLY APPROVED 2 SUBMIT MATERIAL LIST USING THE FOUOWING LAYOUT (DOUBLE SPACED BETWEEN EACH ITEM) ITEM 1. 2. 3. DESCRIPTION PRESSURE MA!NUNE SHRUB HEAD ETC. MANLJfACJUREB MODEi No l.ASCO SCH.40 RAINBIRD 1806-12F ETC. ETC. .3 EOUIPMENT OR MATERIALS !!\STALLED OR FURNISHED WITHOUT THE PRIOR APPROVAL OF THE LANDSCAPE ARCHITECT OR LANDSCAPE COORDINATOR MAY BE REJECTED AND SUCH MATERIALS REMOVED FROM THE SITE AT NO EXPENSE TO THE OWNERIDcVELOPMENT, .4 APPROVAL OF ANY ITEMS. ALTERNATIVE, OR SUBSTITUTIO"l INDICATE ONLY THAT THE PRODUCT($) AP?ARENTl y MEET THE REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS or, THE BASIS OF THE INFORMATION OR SAMPLES SUBMITTED. .5 THE CONTRACTOR IS RESPONSIBLE FOR PERFORMANCE OF SUBSTITUTED ITEMS IF SUBSTITUTION PROVES TO BE UNSATISFACTORY. REPLACE IT WITH ORIGINALLY SPECIFIED ITEIJ.. AT NO COST TO THE OWNER/DEVELOPMENT. 1.!, GUARANTEE: .1 SUBMIT WRITTEN GUARANTEE IN APPROVED FORM THAT ALL WORK SHOWING DEFECTS IN MATERIALS OR WORKMANSHIP WILL BE REPAIRED OR REPLACED AT NO COST TO THI: OWNER/DEVELOPMENT FOR A PERIOD OF ONE YEARS FROM THE DATE OF ACCEPTANCE BY THE OWNER/DEVELOPMENT, 2 THE GUARANTEE FORM SHALL BE RE-TYPED ONTO THE CONTRACTOR'S LETTERHEAD AND CONTAIN THE FOLLOWING INFORMATION A. GUARANTEE FOR IRRIGATION SYSTEM • (PROJECT NAME) WE HEREBY GUARANTEE TKAT THE IRRIGATION SYSTEM WE KAVE FURNISHED A"lD INST ALL ED FOR (PROJECT NAME) IS FRE:E FROM DEFECTS IN MATERIALS AND WORKMANSHIP, AND THE WORK HAS BEEi, COMPLETED IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, ORDINARY WEAR AND TEAR AND UNUSUAL ABUSE, OR NEGLECT EXCEPTED. WE AGREE 10 REPAIR OR REPLACE ANY DEFECTS IN MATERIAL OR WORKMANSHIP WHICH MAY DEVELOP DURING THE PERIOD OF 1 YEAR FROM DAlE OF ACCEPTANCE AND ALSO TO REPAIR OR REPLACE ANY DAMAGE RESULTING FROM THE REPAIRING OR REPLACING OF SUCH DEFECTS Al NO ADDITIONAL COST TO lHE OWN[RiDEVELOPMENT. WE SHALL MAKE SUCH REPAIRS OR REPLACEMENTS WITHIN A REASONABLE TIME, AS DETERMINED BY THE OWNER/DEVELOPMENT, AFTER RECEIPTS or WRIHEN NOTICE IN THE EVENT OF OUR FAlcURE TO MAKE SUCH REPAIRS OR REPLACEMENTS WITHIN A REASONABLE TIME AFTER RECEIPT OF WRITTEN NOTICE FROM THf; OWNER/DEVELOPMENT, WE AUTHORIZE THE OWNER/DEVELOPMENT TO PROCEED TO HAVE SAID REPAIRS OR REPLACEMENTS MADE AT OUR EXPENSE AND WE WILL PAY THE COSTS AND CHARGES THEREFORE UPON DEMAND. B. PROJECT: (PROJECT NAME) C LOCATION: (LEGAL DESCRIPTION OF PROJECT PROPERTY) SIGNED, __________ ~_TITLE: ADDRESS TELEPHONE· DATE AND SIGNATURE. ___ _ 1.4.1 .1 2 .1 2 1 l;,.1 .1 2 .3 .4 1 J; 2 ., 2 .3 1 ~-3 .1 .1 1.!1·5 .1 1.G:, 1.h.1 .1 2 .3 .5 OBSERVATION: INSPECTION SCHEDtJI E IN ALL CASES WHERE OBSERVATION OF THE SPRINKLER SYSTEM WORK IS REQUIRED AND/OR WHERE PORTIONS OF THE WORK ARE SPECIFIED TO BE PERFORMED UNDER THE DIRECTION AND/OR OBSERVATION OF THE LANDSCAPE ARCHITECT OR LANDSCAPE COORDINATOR. THE CONTRACTOR IS RESPONSIBLE FOR NOTIFYING THE LANDSCAPE ARCHITECT OR LANDSCAPE COORDINATOR,4NPJr!l:.,;;.fl1'~~~ I1-/ADVANCE FOR THE FOl..lOWING INSPECTIONS. ACCORDING TO THE TIME INDICATED: IN:,f~ -----------· Pf1E✓OB CONFERENCE -7 CALENDAR DAYS A. B. C. D. E. F_ G, LAYOUT OF CONTROL EQUIPMENT, SPRINKLER HEADS AND PIPING 32 HOURS PRESSURE MAINLINE INSTALLATION AND TESTING -32 HOURS LATERAL TRENCH DEPTH CHECK -32 HOURS COVERAGE TEST -32 HOURS FINAL INSPECTION -48 HOURS NOlif-'Y THE CIJY OF CARLSBAQ 24 HOURS IN ADVANCE OF BEGINNING OF WORK H. NOTIFY THE CITY OF CARLSBAD 24 HOURS IN ADVANCE OF BcG:NNING CONSTRUCTION. WHEN INSPECTIONS HAVE BEEN CONDUCTED BY OTHER THAN THE LANDSCAPE ARCHITECT OR THE LANDSCAPE COORDINATOR, SHOW EVIDENCE OF \'/HEN AND BY WHOM THESE INSPECTIONS WERE MADE. NO INSPECTION WIU COMMENCE WITHOUT AS-BUil T DRAWINGS IN Tl-IE EVENT THE CONTRACTOR CALLS FOR AN INSPECTION WITHOUT AS-BUILT DRAWINGS, WITHOUT COMPLETING PREVIOUSLY NOTED CORRECTIONS. OR WITHOUT PREPARING THE SYSTEM FOR INSPE:CTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REIMBURSING THE LANDSCAPE ARCH11ECT OR TI-1E LANDSCAPE COORD!NATOR AT THE RATE OF $95 00 PER HOUR (PLUS ANY TRANSPORTATION COST) FOR THE INCONVENIENCE NO FURTHER INSPECTIONS WILL BE SCHEDUl ED UNTIL THIS CHARGE HAS BEEN PAID. TESTING: GENERAL, FURNISH AU NECESSARY TESTING EQUIPMENT AND PERSONNEL TO MEET TESTING REQUIREMENT CORRECT ALL DEFECT AND RETEST UNTIL ACCEPTANCE BY OWNER. TESTS MAKE HYDROSTATIC TESTS ONLY IN THE PRESENCE OF THE REPRESENTATIVE OF THE OWNER/DEVELOPMENT. AIR PRESSURE CHECK ALL LINES THAT COULD WEAKEN OR DAMAGE ANY MAJOR STRUCTURES OR HARDSCAPES, IF WATER WERE USED. NO PIPE SHALL BE BACKFIUED UNTIL IT HAS BEEN INSPECTED, TESTED, AND APPROVED. FURNISH NECESSAHY FORCE. PUMP AND All OTHER TEST EQUIPMENT. TEST ALL PRESSURE MAINLINES UNDER A HYDROSTATIC PRESSURE OF 150 P.S.I. FOR A PERIOD OF TWO HOURS ALL TESTING SHALL BE APPROVED PRIOR TO THE INSTALLATION OF CONTROL VALVES, HOSE BIB, OR OTHER VALVE ASSEMBLIES, ADJUSTING SYSTEM THE CONTRACTOR SHALL FLUSH AND ADJUST ALL IRRIGATION HEADS AND VALVES FOR OPTIMUM PERFORMANCE AND TO PREVENT OVERSPRAY ONTO WALKS ROADWAYS, BUILDINGS, WAUS ANO OTHER STRUCTURES AS MUCH AS POSSIBLE ' IF IT IS DETERMINED THAT ADJUSTMENTS IN THE IRR13ATION EQUIPMENT OR NOZZLE CHANGES WILL PROVIDE PROPER AND MORE ADEQUATE COVERAGE, MAKE ALL SUCH CHANGES OR MAKE ARRANGEMENTS WITH MANUFACTURER TO HAVE ADJUSTMENT MADE. PRIOR TO PLANTING. ADJUST CONTROL VALVES (BATTERY SYSTEMS) SO THAT THE MOST REMOTE SPRINKLER HEADS OPERATE AT THE PRESSURE RECOMl~ENcJED BY SPRINKLER MANUFACTURER C.OYERAGE TEST WHEN THE IRRIGATION SYSTEM IS COMPLETED. PERFORM A COVERAGE TEST IN THE PRESENCE OF THE LANDSCAPE ARCHITECT OR LANDSCAPE COORDINATOR TO DETERMINE IF THE WATER COVERAGE FOR PL.ANTING AREAS IS COMPLETE AND ADEQUATE FURNISH ALL MATERIALS AND PERFORM ALL WORK REQUIRED TO CORRECT ANY INADEOUACIES OF COVERAGE DUE TO DEVIATIONS FROM THE PLANS OR WHERE THE SYSTEM HAS BEEN WILLFUU Y INSTALLED AS INDICATED ON THE DRAWINGS WHEN IT IS OBVIOUSLY INADEQUATE OR INAPPROPRIATE, WITHOUT BRINGING THIS TO THE ATTENTION OF THE LANDSCAPE ARCHITECT OR LANDSCAPE COORDINATOR THIS TEST SHAU BE ACCOMPLISHED BEFORE Am GROUND COVE.fl IS PLA"lTED uf1T OFL,<,.1'-lSVb l-Al--trc6Cf, ~ ;;_ ,NSflcc...TOIZ.5rlJ-.I-L ~c~ ~T Tll--H:' D'F ~!' ie6f. El"IA\ ACCEPTANCE WHEN ALL WORK UNDER THIS CONTRACT HAS BEEN COMPLETED. INCLUDING TESTING ADJUSTMENTS. ADDITIONS OR DELETIONS. THE CONTRACTOR WILL NOTIFY THE OWNER FOR FlNAL INSPECTION AND APPROVAL FINAL ACCEPTANCE BY THE OWNER DOES NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITY OF WARRANTY. MINOR ADJUSTMENTS MINOR ADJUSTMENTS (LEVELLING AND CLEANING SPRINKLER HEADS. VALVE BOXES, ETC INCLUDING PROTECTION FROM VANDALISM) WILL BE MADE BY THE OWNE.R AFTER ACCEPTANCE OF THE SYSTEM AND DURING THE WARRANTY PERIOD RECOR:) DRAWINGS: RECORD DRAWINGS RECORD DRAWINGS SHALL BE PREPARED AND SHALL SHOW AU CHANGES IN THE WORK CONSTITUTING DEPARTURES FROM THE ORIGINAL CONTRACT DRAWINGS INCLUDING THOSE INVOLVING BOTH CONSTANT-PRESSURE AND INTERMITTENT - PRESSURE LINES AND APPURTENANCES. ALL CONCEPTUAL OR MAJOR DESIGN CHANGES, INCLUDING ANY CHANGES THAT MAY BE AFFECTED BY THE REQUIREMENTS OF THESE STANDARD SPECIFICATIONS, SHALL BE APPROVED BEFORE IMPLEMENTING THE CHANGES IN THE CONSTRUCTION CONTRACT, FAILURE TO RECEIVE PRIOR APPROVAL MAY RESULT ttJ TERMINATION OF SERVICE. RECORD ACCURATELY ON ONE SET OF BLACK AND WHITE PRINTS OF THE IRRIGATION DRAWINGS, ALL CHANGES IN WORK CONSTITUTING DEPARTURES FROM THE ORIGINAL CONTRACT DRAWINGS, INCLUDING CHANGES IN BOTH PRESSURE AND NON-PRESSURE LINE. UPON COMPLETION OF EACH INCREMENT OF WORK. TRANSFER ALL SUCH INFORMATION AND DIMENSIONS TO THE PRINTS, RECORD CHANGES AND DIMENSIONS IN A LEGIBLE AND PROFESSIONAL MANNER. WHEN THE DRAWINGS ARE APPROVED. TRANSFER ALL INFORMATION TO A SET OF REPRODUCIBLE SEPIA MYLAR DRAWINGS SUPPLIED AT COST BY THE LANDSCAPE ARCHITECT. DIMENSION FROM TWO PERMANENT POINTS OF REFERENCE (BUILDINGS. MONUMENTS, SIDEWALKS. CURBS, PAVEMENT). POST INFORMATION ON AS-BUILT DRAWINGS DAY TO DAY AS THE WORK IS INSTALLED. ALL DIMENSIONS NOTED Otl DRAWINGS SHALL BE 114 INCH IS SIZE / .7 .8 1 {i>,2 .1 1-(,.3 -1 1.T 1.,.2 j_J_3 1.7.4 1.1 5 1.1 6 1.7 7 1.7 8 1.79 1.-710 1 . .r.11 j UPON COMPLETION OF EACH INCREMENT OF WORK. ALL REQUIRED INFORMATION AND DIMENSIONS SHAU BE TRANSFERRED TO TI-IE RECORD DRAWINGS. FACILITIES AND ITEMS TO BE LOCATED AND VERIFIED ON THE RECORD DRAWINGS. SHOW DIMENSIONAL LOCATION AND DEPTH OF THE FOLLOWING: A. POINT OF CONNECTION B. ROUTING OF IRRIGATION PRESSURE MAINLINES (DIMENSION MAXIMUM 10 FEET ALONG ROUTING AND ALL DIRECTIONAL CHANGES.) C. GATE VALVES. D. IRRIGATION CONTROL VALi/ES E. OTHER RELATED EQUIPMENT (AS DIRECTED BY THE LANDSCAPE ARCHITECT) MAINTAIN AS BUILT DRAWINGS ON THE SITE AT ALL TIMES THESE DRAWINGS ARI: SUBJECT TO INSPECTION AT ANYTIME. MAKE AU CHANGES TO REPRODUCIBLE DRAWINGS IN INK (NO BAUPOINT PEN) USE ERADICATING FLUID WHEN REDOING DRAWINGS. CHANGES AND DIMENSIONS SHALL BE RECORDED IN A LEGIBLE AND PROFESSIONAL MANNER. RECORD CONSTRUCTION DRAWINGS SHALL BE MAINTAINED AT THE JOB-SITE DURING CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS-BUILT SEPIA MYLAR TO OWNER UPON COMPLETION OF CONSTRUCTION OPERATION AND MAINTENANCE MANUAi S PREPARE AND DELIVER TO THE OWNER WITHIN 10 CALENDAR DAYS PRIOR TO COMPLETION OF CONSTRUCTION, ALL REQUIRED AND NECESSARY DESCRIPTIVE MATERIAL IN COMPLETE DETAIL AND SUFFICIENT QUANTITY, PROPER~ Y PREPARED IN FOUR (4) INDIVIDUAL BOUND COPIES DESCRIBE THE MATERIAL INSTALLED IN SUFFICIENT DETAILS TO PERMIT QUALIFIED OPERATING PERSONNEL TO UNDERSTAND. OPERATE AND MAINTAIN ALL EQUIPMENT. INCLUDE SPARE PARTS LIST AND RELATED MANUFACTURER INFORMATION FOR EACH EQUIPMENT ITEM INSTALLED. EACH MANUAL Sf-lALL INCLUDE THE FOLLOWING: A. INDEX SHEET STATING CONTRACTOR'S ADDRESS AND TELEPHONE NUMBER 8. DURATION OF GUARANTEE PERIOD C LIST OF EQUIPMENT WITH NAMES AND ADDRESSES OF MANUFACTURER'S LOCAL REPRESENTATIVE D. COMPLETE OPERATING AND MAINTENANCE INSTRUCTIONS ON ALL MAJOR EQUIPMENT. IN ADDITION TO THE MAINTENANCE MANUALS, PROVIDE THE MAINTENANCE PERSONNEL WITH INSTRUCTIONS FOR MAJOR EQUIPMENT AND SHOW WRITTEN EVIDENCE TO THE LANDSCAPE ARCHITECT OR LANDSCAPE COORDINATOR AT THE CONCLUSION OF THE WORK THAT HIS SERVICE HAS BEEN RENDERED CHECKLIST COMPLETE THE FOLLOWING CHECKLIST AT TI-IE END OF THE PROJECT, USING THE FORMAT SHOWN: A. PLUMBING PERMfTS (IF NONE REQUIRED, SO NOTE) B. MATERIALS APPROVAL C. PRESSURE MAINUNE TEST (BY WHOM AND DATE) D. AS-BUILT DRAWINGS COMPLETED (RECEIVED BY AND DATE) E. MATERIALS FURNISHED (RECEIVED BY AND DATE) F. SYSTEM AND EQUIPMENT OPERATION INSTRUCTIONS (RECEIVED BY AND DATE! G. WRITTEN GUARANTEE BY CONTRACTOR (RECEIVED BY AND DATE) FORWARD SIGNED AND DATED CHECKLIST TO LANDSCAPE ARCHITECT OR LANDSCAPE COORDINATOR BEFORE FINAL ACCEPTANCE OF PROJECT GENERAL REO\JIREMENTS doDE REQUIREMENTS SHALL BE THOSE OF STATE AND MUNICIPAL CODES AND REGULATIONS LOCALLY GOVERNING THIS WORK. PROVIDING THAT ANY REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS, NOT CONFLICTING THEREWITH BUT EXCEEDING THE CODE REQUIREMENTS SHALL GOVERN, UNLESS WRITTEN PERMISSION TO :n-tE COl'-/TR.ARY IS GRANTED BY THF AGENCY. EXTREME CARE SHALL BE EXERCISED IN EXCAVATING AND WORKING IN THE AREA DUE TO EXISTING UTILITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGES CAUSED BY HIS OPERATIONS. .CONNECTIONS SHALL BE MADE AT APPROXIMATELY THE: __ 1,S,CATIONS SHOWN or, THE DRAWINGS CONTRACTOR SHALL BE RESPONSIBLE FOR MINOR CHANGES CAUSED BY ACTUAL SiTE CONDITIONS SCALED DIMENSIONS ARE APPROXIMATE BEFORE PROCEEDING WITH ANY WORK, THE CONTRACTOR SHALL CAREFUU Y CHECK AND VERIFY AU DIMENSIONS PLAN LOCATIONS OF HEADS, VALVES, CONTROLLER AND PIPE LINES ARE DIAGRAMMATIC ANO INDICATE THE SPACING AND RELATIVE LOCATIONS OF ALL INSTALLATIONS, ALL LINES SHALL HAVE A MINIMUM CLEARANCE OF SIX (6) INCHE,S FROM EACH OTHER. AND FROM LINES OF OTHER TRADES, PARALLEL LINES'SHALL NOT BE INSTALLED DIRECTLY OVER ONE ANOTHER. DIELECTRIC BUSHINGS SHALL BE USED IN ANY CONNECTIONS WITH PIPING OF DISSIMILAR METAL MATERIALS POINT OF CONNECTION SHALL BE APPROXIMATELY AS SHOWN ON DRAWINGS CONNECT NEW UNDERGROUND PIPING AND VALVES AND PROVIDE ALL FLANGES, ADAPTERS OR OTHER NECESSARY FITTINGS FOR CONNECTION PERMISSION TO SHUT OFF ANY EXISTING IN"USE WATER LINES MUST BE OBTAINED-48 HOURS IN ADVANCE. IN WRITING FROM THE OWNER/DEVELOPMENT. THE CONTRACTOR SHALL RECEIVE INSTRUCTIONS FROM THE OWNER/DEVELOPMENT, AS TO THE EXACT LENGTH OF TIME Of EACH SHUT-OFF. CONTRACTOR SHALL ACQUAINT HIMSELF WITH AU SITE CONDITIONS. THE WORK SHALL BE ACCEPTED IN WRITING V.'HEN THE ENTIRE SCOPE OF WORI( HAS BEEN COMPLETED SATISFACTORILY TO TI-IE OWNER. JUDGING THE WORK. NO ALLOWANCE FOR DEVIATION FROM THE ORIGINAL PLANS AND SPECIFICATIONS WILL BE MADE UNLESS PREVIOUSLY APPROVED BY THE OWNER WHEN M'Y ITEM APPEARS ON THE PLAN AND NOT IN THE SPECIFICATIONS, OR IN THE SPECIFICATIONS AND NOT ON THE PLANS, IT SHALL BE CONSIDERED IN BOTH. Wf-lEN CONl'LICTS ARISE, THE HIGHEST STANDARDS WILL PREVAIL. THE OWNER OR HIS AUTHORIZED REPRESENTATIVE SHALL HAVE THE FINAL AUTHORITY ALL ITEMS OF THE PROJECT APPROVED ENGINEERING PLANCHECKER DATE PART 2 -PRODUCTS 2.1 2.1. 1 -, 2 , .1.2 , 1 2 1 :, 1.4 .1 2 2.1.5 '1 2 1.6 .1 2 1.7 2 1.8 .1 2.1.9 Z.1.10 2.1.11 2.1 12 .1 2 MATERIALS: PIPING PIPE SIZES SHOWN ARE NOMINAL INSIDE DIAMETER UNLESS OTHERWISE NOTED. POLYVINYL CHLORIDE PIPE PQTABLE· (1) PVC PLASTIC PRESSURE LINES: f-OR PIPING UPSTREAM OF REMOTE CONTROL VALVES AND QUICK COUPLERS. ALL ONE AND ONE HALF (1-1/2) INCHES AND SMAUE SHALL BE TYPE 1, GRADE 2, (IMPACT MODIFIED). DESIGNED AS ASTM 1785-76. SCHEDULE 40. (2) PLASTIC NON-PRESSURE LINES: FOR PIPING DOWNSTREAM OF REMOTE CONTROL VALVES. TYPE 1, GRADE 2, (IMPACT MODIFIED). AS DESIGNATED AS PVC 1220, CLASS 200, (SDR21). CONFORMING TO COMMERCIAL STANDARDS CS256-63 BRASS PIPE SHALL BE !PS STANDARD WEIGHT 126 POUNDS. 85% RED BRASS. FITTINGS A"lD CONNECTIONS; POLYVINYL CHLORIDE PIPE FITTINGS ANO CONNECTIONS: TYPE Ii, GRADE 1, SCHEDULE 40 HIGH IMPACT MOL:)ED FITTINGS, MANUFACTURED ff1OM VIRGIN COMPOUNDS AS SPECIFIED FOR PIPING. TAPERED SOCKET OR MOLDER THREAD TYPE SUITABLE FOR EITHER SOLVENT WELD OR SCREWED CONNECTIONS. MACHINE THREADEcO FITTINGS AND PLASTIC SADDLE AND FLANGE FITTINGS ARE NOT ACCEPTABLE. FURNISH FITTINGS PERMANENTLY MARKED WITH FOLLOWING INFOf<MATION· NOMINA_L PIPE SIZE, TYPE AND SCHEDULE OF MATERIAL, AND NATIONAL SAN-ITATION FOUNDATION (NSF) SEAL OF APPROVAL. PVC FllTING SHALL CONFORM 10 ASTM 02454 AND D24S6. BRASS PIPE FITTINGS AND CONNE:CTIONS. STANDARD 125 POUND CLASS 85% RED BRASS FITTINGS AND CONNECTIONS. !1]a_RS_; Al L SPRINKLER HEAD$ SHALL HAVE RISERS AND SWING JOINTS AS SHOWN IN THE DETAIL DRAWINGS ALL R:SERS AND SWING JOINTS SHALL BE MANUFACTURED BY DURA OR EQUAL, SCHEDULE 40 FITTINGS. ElillNGS FITTINGS. IN GENERAL, FOR ALL INSTALLATIONS SHALL BE CONSIDERE,~ INCIDENTAL TO THE CONTRACT PRICE AND SHALL BE THE CONTRACTOR~ RESPONSIBILITY TO PROVIDE ALL OF REQUIRED FITTINGS TO COMPLETE THE CONTRACT. ALL TEES FOR THE INSTALLATION OF SWING JOINTS Will BE INSTALLED WITH DURA. LASGO TE.E OR EQUAL. ANGLE CONTROL VALVE ANGLE CONTROL VA, VES SHALL BE OF THE MANUFACTURER SHOWN ON THE DRAWINGS OR APPROVED EQUAL. EACH ANGLE VALVE SHALL HAVE UNION. YAI VE BOX ALL VALVES INCLUDING PRESSURE REGULATING VALVES. HOSE BIBB VALVES SHALL BE INSTALLED IN SUITABLE VALVE BOXES AS SHOWN IN DETAILS. All SHALL BE MARKED "PRV--OR "HB" RESPECTIVELY. s~ SPRINKLER HEADS SHALL BE AS REQUIRED ON THE DRAWINGS OR APPROVED EQUAL. ALL SPRINKLER HEADS ARE TO HAVE FACTORY BUILT IN CHECK VALi/ES l"IYERTED HOSE: BIBB SHALL BE OF THE STYLE AND MANUFACTURE SHOWN ON THE DRAWING, OR APPROVED EQUAL. ANO INSTALLED PER DETAIL DRAWINGS AND MANUFACTURERS RECOMMENDATION. BACKFLOW PREVENTER: UNIT SHALL BE AS SHOWN ON PLANS OR EQUAL, AS APPROVED BY ARCHITECT . CONCRETE. FOOTINGS SHALL BE 2,000 PSI CONCRETE AT 28 DAYS BACKFILL SHALL BE CLEAN FILL SOIL WITH NO ROCKS OR CLOD 112" OR LARGER CONTRACTOR SHALL PROVIDE TO THE OWNER FOUR (4) WRENCHES rOR REMOVING EACH DIFFERc.NT TYPE OF S?RINKLER HEAD ONE LOOSE KEY FOR EACH HOSE BIBB El,RT 3 · EXFCLfTION 3.1 3.1 .1 3 1 2 3 1 .3 3 .1.~ GENERAL REOUIRC:MENTS: LOCATIONS ON DRAWINGS ARE DIAGRAMMATIC AND APPROXIMATE ONLY, AND SHALL BE CHANGED AND ADJUSTED AS NECESSARY AS DIRECTED TO MEET EXISTING CONDITIONS AND OBTAIN COMPLETE WATER COVERAGE LOCATE AND STAKE ALL WORK AND OBTAIN APPROVAL OF THE ARCHITECT BEFORE INSTALLATIONS. INSTALL AND EXTEND SYSTEM AS SHOWN ON THE DRAWINGS, AND AS NECESSARY TO CARRY OUl Tl-IE INTENT OF THE DRAWINGS AND SPECIFICATIONS. LOCATE LINES, VALVES AND OTHER UNDERGROUND UTILITIES AND RECEIVE THE APPROVAL OF Tl-IE ARCHITECT BEFORE DIGGING TRENCHES. REFER TO THE CITY OF CARLSBAD Sl ANDARDS FOR POTABLE PIPE INSTALLATION. ALL CITY OF CARLSBAD STANDARDS TAKE PRECEDENCE OVER PLANS AND SPECIFICATIONS FOR TI-iE PROJECT UNLESS NOTED AND APPROVED. _A_PF1f{0 \1ED FO F~ PLli,NT1N "A_ND IRRIG i'I.. 1'10 N O NL)r, lNC:LlJDlNG PRE:CISF. "AS BUil T" RCE ___ EXP_ OAT£ LCJCA"fION OF' PLANTIN.G i'I..REi\S. REVl[WITl BY: INSPECTOR 0Al£ __,__~---+-------I ~1CT I CITY OF CARLSBAD I SHl[~TS l !==::=~==:::P::L::A.:::N:::N::IN:::G==::::::D:=£:::::PAA:=TM:::::::::E:::::N=T==~=:.=4-"=~ LANDSCAPE IMPROVEMENTS FOR: PLANNING AREA 27 !AR H SE II l" i,,.!,S.o. eLU£P'AINT 3.2 INSTALLATION OF IRRIGATION SYSTEM: 3.2.1 EXCAVATION AND BACKFILLING OF TRENCHES· .1 EXCAVATE TRENCHES. PREPARE SUBGRADE, AND BACKFILL TO LINE AND GRADE WITH SUFFICIENT ROOM FOR PIPE FITTINGS. TESTING AND INSPECTING OPERATIONS. DO NOT BACKFILL UNTIL THE PIPE SYSTEM HAS BEEN SUBJECTED TO A HYDROS TA TIC TEST AS SPEClflED. 3 IBJ:N,Qtl lNQ IlfilQ_I.I_QH.AflE8.S_'lll:l.E.8.E.J.Q"...S_QJJ....&$Jl.E EN SPREAD .4 .5 .6 .7 .8 3 2 2 .1 2 2 4 5 .6 ,7 .8 .9 3 2 3 .1 .10 . 11 2 3 2.4 .1 3.2.5 .1 2 3.2 6 . 1 2 3.2.7 .1 3 2 9 .1 2 3.3 (1) DEPOSIT TOPSOIL ON ONE SIDE OF TRENCH AND SUBSOIL ON OPPOSITE SIDE. SUBSOIL SHALL BE FREE OF ALL ROCKS AND CLODS 112 INCH IN DIAMETER, DEl3RIS, AND LITTER, PRIOR TO USE AS BACKFILL WHERE SO INDICATED ON DETAIL. REPAIR ANY LEAKS AND REPLACE ALL DEFECTIVE PIPE OR FITTINGS UNTIL LINES MEET TEST REQUIREMENTS DC NOT COVER ANY LINES UNTIL THEY HAVE BEEN INSPECTED ANO Al'PROVED FOR TIGHTNESS, QUALITY OF WORKMANSHIP AND MATERIALS. BACKFILL TRENCHES. Af-fER APPROVAL OF PIPING, WITII SUITABLE AND APPROVED MATERIAL, TAMPING SOIL AROUND PIPE AND THOROUGHLY COMPACTING ALL TRENCH FILLS UNTIL 90% COMPACTiON HAS B[EN ACHIEVED. BACKFILL MATf'RIAI_ SHALL BE AN APPROVED SOIL, FR~E FROM ROCKS AND Cl ODS 1/2" AND LARGER . CONTRACTOR SHALL NOT INSTALL PiPE ACROSS CONCRETE DRAINAGE SWALE. CONTRACTOR SHALL JACK OR BORE UNDER SWALE TYPICAL. lrJSIAlLAUQ!i__O£..PQLJ'YIJ'1Y_l_Q--I_LQB.IJ2E_E]f'...E; BECAUSE OF THE NATURE OF PLASTIC PIPE AND FITTINGS, EXERCISE CAUCION lfl HANDLING, LOADING AND STORiNG, TO AVOID DAMAGE. THE PIPE AND FITTINGS SHALL BE STORED UfJIJl::11 COVER UNTIL USED, AND SHALi. BE TRANSPORTED IN A VEHICLE WITH A BED LONG ENOUGH TO ALLOW Tl IE LENGTH OF PIPE TO LAY FLAT so AS NOT TO BE SUBJECTFD TO UNDUE BEN)ING on CONCENTRA l ED EXTERNAL LOAD AT ANY POINT. ANY PIPE THAT HAS BEEN DENTED OR DAMAGFD SHALL BE DISCARDED UNTIL SUCH DENTED OR DAMAGED SECTION IS OlJT AND REJOINED WITH A COUPLING TRENCH DEPTH SHALL BE AS SPECIFIED ABOVE FROM TI,E FINISH GRADE TO TIJE TOP OF THE PIPE THE' BOTTOM OF THE TRENCH SHALL BE FREE OF ROCKS, CLODS, AND OTHER SHARP-EDGE'D OBJECTS. PIPE ENDS AND FITTINGS SHALL BS WIPED wm, MEK, OR EQUAL, B[FORE WELDING SOLVENT IS APPLIED. WELDED JOINTS SHALL BE G'VEN A MINIMUM OF 15 MINUTES TO SET BEFORE MOVING OR HANDLING ALL FIELD CUTS SHALL BE BEVELLED TO REMOVE BURRS AND EXCESS BEFORE FITTING AND GLUING TOGETHER. PIPE SHALL BE SNAKED FROM SIDE-TO-SIDE OF TRENCH BOTTOM TO ALLOW FOfl EXPA'-JSION AND CONTRACTION. CENTER LOAD PIPE WITH SMALL AMOUNT OF BACKFILL TO PREVENT ARCHING AN::> SLIPPING UNDER PRESSURE LEAVE JOINTS EXPOSED FOR INSPECTION DURING TESTING. NO WATER SHALL BE PERMITTED IN THE PIPE UNTIL INSPECTIONS HAVE BEEN COMPLETED AND A PERIOD OF AT LEAST 24 HOURS HAS ELAPSED FOR SOLVENT WEl,D SETTING AND CURING. PLASTIC TO METAL JOINTS SHALL BE MADE WITH P...ASTIC MALE ADAPTERS. METAL NIPPLE HAND TIGHTENED, PLUS ONE TURN WITH A STRAP WRENCH. PLASTIC TO PLASTIC JOINTS SOLVENT-WELD, USING SOLVENT RECOMMENDED BY PIPE MANUFACTURER ONLY. SOLVENT-WELD JOINTS· ASSEMBLE PER MANUFACTURER'c RECOMMENDATION . lli.S.L&lAJION OF BRASS£'!££. CUT BRASS PIPING BY POWER HACKSAW, CIRCULAR CUTTING MACHINE USING AN ABRASIVE WHEEL, OR HAND HACKSAW CUT NO PIPING WITH METALLIC WHEEL CUTTER OF ANY DESCRIPTION. REAM AND REMOVE ROUGH EDGES OR BURRS SO SMOOTI! AN UNOBSTRUCTED FLOW IS OBTAINED. CAREFULLY AND SMOOTHLY PL.ACE ON MALE THREAD ONLY. TIGHTEN SCREWED JOINTS WITH TONGS OR WRENCHES CAULKING IS NOT PERMITTED. VALVES ALL VALVES SHALL BE INSTALLED AS SHOWN IN THE DETAILS AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND AS REQUIRED BY THE CiTY OF CARLSBAD FOR IDENTIF1CATION, PER POTABLE WATER STANDARDS. VALVE BOX INSTALL VALVE BOXES AS SHOWN ON DETAIL. INSTALL NO MORE THAN ONE HOSE BIBB VALVE PER BOX VALVE BOXES INSTALLED NEAR WALKS SHALL BE 6' FROM THOSE ITEMS. AU BOXES ARE TO BE MARKED AS TO THE TYPE OF VALVE. SPRINKLER HEADS ALL SPRINKLER HEADS SHALL BE INSTALLED AS PER DETAILS SHOWN . NOZZLE SIZE OF ALL HEADS SHALL BE ADJUSTED TO SUIT ANY PARTICULAR CONDITIONS OF THE AREA THIS SHALL BE DONE AFTER THE SYSTEM HAS BEEtl THOROUGHLY TESTED, IMMEDIATELY AFTER WRITTEN NOTIFICATION BY THE ARCHITECT TO DO SO. INVERTED HOSE BIBB· INSTALL AU INVERTED HOSE BIBBS AS INDICATED ON DRAWl"IGS AND AS DIRECTED. SET ALL VALVES PLUf.'B AND TRUE TO FINISH GRADE AW) A MAXIMUM OF 6 l"ICHE!; FROM PAVING, WALKS, HEADERS OR CURBS, AND AS SHOWN ON PLANS AND AS DIRECTED BACKFI OW PREVENTER BACKFLOW PREVENTER ASSEMBLY SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, LOCATED AND AS DIRECTED ON DRAWINGS, AND SHALL CONFORM TO ALL APPLICABLE CODE AND ORDINANCE REQUIREMENTS EXACT LOCATION AND POSITIONING SHALL BE VERll'IED ON THE SITE BY THE ARCHITECT. CLEAN-UP: AS PROJECT PROGRESSES, CONTRACTOR SHALL MAINTAIN ALL AREAS IN A NEAT MANNER AND REMOVE UNSIGHTLY DEBRIS AS NECESSARY. AFTER COMPLETION OF THE PROJECT, CONTRACTOR SHALL REMOVE ALL DEBRIS AND CONTAINERS USED IN ACCOMPLISHING WORK. HE SHALL SWEEP AND GLEAN ALL SIDEWALKS, ASPHALT, AND CONCRETE AREAS ADJACENT TO THE PLANTINGS. • END OF SECTION ·• "AS BUil T" .\.,\'"f·•, ·1· ·.l-.)"DT('. :\1-'l()"• 0 ;-~-~ \ J_; \._,_ 1... _J:. J.\ . .:..\ INc:1_,UJ)INC F)i~(1,:c:1sri: RCE ___ _ EXP. ____ _ DATE APPROVED REVIEWED BY: ENGINEERING PLANCHECKER DATE INSPECTOR DATE 1--~----+--+----------------+----+--+---------if-------------1 I s~-EET I CITY OF CARLSBAD [SH,4-EETS j -" PLANNING DEPARTMENT ::=..==-==========:::'.....'.::=--===: 1-----+---+-----------------------+----+---+-----t-----t t----1-----t-------------------~ ... ----+---+---+----tl LANDSCAPE IMPROVEMENTS FOR: PLANNING AREA 27 #IAR6, PtfASE ll -i\ A, F"ourth A.-@nu@ Corpora!~ ~ntart----1-----t--------------------+-----t------t---·->-------I 1, '~ L_l~ ~~'o:':;a~~~';;~;;sui:•200 1---------+--+------------------t---+--+---+------I APPR0~-¥//,-'••('7 /J,,~ zzc.,u,. ... _, , \ (6191239-2•5oJF,e.x 239-o,07 1---------+--+------------------+-----+--+---+------1 Ass1s'WI'! PLAN)(ING DIREcTar= DATE~ ~ A,chitectuce. Ai,~ ::If 0?-c,39' t--~-1-----+-------------------1----·---t----t----+------t ~:;::::~=:::::.;z:.~============--;;:'.====; t---;O:-;A"'TE~1-::-JNl;;-;TI;;--;Al.c-7f------------------·· 1------,-0A---,TE=--+-IN-ITI-Al.-t--ll-A-=TEc----t-c-lN---,ITI=-Al.----t D'M'< BY: ' I PROJECT NO_ J; DRAWING N 0. EN<ll>1ELR Of WORK REVISION DESCRIPTION OTKER APPROVAL aTY APPROVAl. ~~ :~'. ---_ G 1· 90-34 52G--4L ~ /&. Ml;SA -8LU1e:PRINT IRRIGATION LEGEND SYMBOL OE~l'RIPTlnNtMAN 11 FAl'TIIREtMnOEL NO, RADIIIS PSI Xv \\I • TORO 570S STREAM SPRAY W/35 DEG. NOZ. F,H,Q. INSTALL WIFACTORY CHECK VALVE 13' TORO570S FLAT STREAM SPRAY W/10 DEG NOZ. F,HO. INSTALL WI FACTORY CHECK VALVE 12' ,, I I \ TDPC) 5705 o~ S?f¥:. Y ('.£) fC)f'-c/1 7 I+ 3t.;NK,_1 VoZ. l 5 I !--lsT,1-.1..J.-J,J/ ~-[ c)lt!tf< V,£.1....vE f/i c;:. T~-C)S;05 J-:!:f-:,.---r ;s~ ~ (£i/ZJF:, t-i/; C1 DEGr. ,'-/oz. )21 ! 11577--;LL ;~-~7 a::.T cY-lev::!. v4 '-,c& H; cQ_ CHAMPION #300 MANUAL CONTROL VALVE 1" SIZE FEBCO 825Y REDUCED PRESSURE BACKFLOW PREVENTER AND 'WVE" STRAINER CHAMPION 1-401 LK HOSE BIB W/ LOOSE KEY HANDLE (INSTALLED IN PLASTIC VALVE BOX) 1" WILKINS 70 SERIES REGULATING VALVE SET@ 75 PSI 314" DOMESTIC WATER METER BY OTHERS CLASS 200 PVC LATERAL LINE (MIN. 12" COVER) 20 30 30 PRECIP. RATE 1.8,1.0,.60 .69 1.8,1.0,.60 1.13 A A C D E F -----SCHEDULE 40 PVC MAINLINE (MIN. 18" COVER) FOR 1-1/2" AND SMALLER ANO CLASS 315 FOR 2" AND LARGER I \ .,--+'\--i---MANUAL CONTROL VALVE SIZE -I -I ~VALVE GPM APPROVED ENGINEERING PLANGHECK[H DATE G H J "AS BUil T" RCE ___ EXP. ___ _ REVIEWt:D BY: INSPECTOR DATE I Sep] CITY OF CARLSBAD I s1~_rs j 1---+-----,f-----------------+-----t-----t--r--j PLANNING DEPAR1MENT f 1---+--f-----------------+-----t-----t--r--j LANDSCAPE IMPROVEMENT FOR: ~" s~ -"'~<::::,{!, IS/J;j-~'~._,,~ Ir-, I'\ /j._ Fou,thAvenoeCo,pma1eC..01., __ ~ 1551 Fourth Aven1.1e/Suitti 200 1-----1---1---------------+----;----;--;---; San Dte,Qo, CA 92101 / . · kfr,o J .. • j {619) 239-2450/FA)( 239-<>107 1-----1---1-----------------+----;----;--;---; . PLANNING AREA 27 I ~VIARA_P~ASE II APP;~?', o/.. # £ ,,. ,1 7. 2£7-'l ~ ASS!~ AMI PLAJ\1/QJNG DIRECT01¥~~-----'~DA4T;E ..,L.:2__ J---:::-=::--t--;;--;;-;;~t--------------·----c---+----=::-t==:c-:--t--=-:--;;:--r.::-::::-:-:-1 CATE IHJTI,\L DATE INITI,\L DATE ~ITIAL ENWIED, OF WOfO< REVISION DESCRIPTION 01\lER APPROVAL CITY APPROVAL OWN BY: , l PROJECT NO. I DRAWING NO. CHKD BY: --,___C_:f_9'.:'l __ -_3'f _ __, 3%,--4-:L RVWD BY: . ... ' ' NOTE :FACTORY ASSEMBLED SWING JOINT OR EQUAL IR!11GA TION HEAD DURA MOOEL + SIZE PVC GRADE F'<'TPI lf)l=f) -, :;,1.,H (lU Nif'i'-LI:: #4 REBAR TO 24' DEPTH ---- 90· ELL (SLIP X SLIP) ·700 SERIES 570 SERIES +007--9-0 3/4' +005-9-0 112· SCH 40 SCH 40 SPRING LOADED CHECK VALVE , AS REQUIRED TO PREVENT SOL VENT WELD {SLIP X SLIP) SWl!-JG )( SLIP--,..: SOLVENT WELD SCH~O-..._ PVC PIPE ~\--'>.9'" -~ 90'ELL (FIPT X SWING) MALE FITTING ADAPTER (SWING )( SPIGOT) i LOW HEAD DRAINAGE; USE 1 FACTORY CHECK VAi.VE IF - AVAILABLE -. VERIFY WITH LEGEND,____ PVC FITTING -- PVC LATERAL (COVER AS NOTED N I.EGEND) SCH 00 PVC NIPPLE ' . ' SCH 80 PVC PIPE, 12• ' 9cf ELL (SWING X SWING) SWING JOINT ---------------------------B E/C'Er'T t.S Sf-f~)Wr✓. ThEi1E SH/C-,U ... ~.~ r\'·=• F r-1n·>JGS OR C .. /s'!\1EC,T10t'~$1C '.JIHE.R FA2,~i l !F:$ Bl TW~ ~r'-i ;·'l-lt !.'.!:IER J--.'.•J[: ~.AC~r-LC'N A.:,SEl/,QLY ·--- ~\-"~E D~c~: F LC,-.· r:: ~EVEJ\ '• E:: F--. 1-.~·-$~!,l,~,L.. v rJUS 1 EE i'·~Si AL'~ ED A !J,!"-J !J.Ur-~ o:= {6"! t.N[; '✓0-10 EXC[E D At/ t-j 'k~Ur/ c+ '\'.1C F"[ ET (2") ~ ROM Ir·,~ l.t,~ T~.-; l·X-.,1:.~T \.'•-iJ-,C. ~i•J S ·,',1,:)..Jt;) ·.:.:E:"JLiRE --HE S;..CKFLU,·, ,t.S$~!.',8.... Y TO BC !'-~ST.4~'.-=°:• !!\: J-. r-'~;3t._:c h 1U~-!1-'J~-\'J .. Y :~-~ V.'HICH C_A:.::-!::: ,-,~~-~.)ACl<J::,_ch'\1 .t..SS~V-F..i. ..,, !/~;ST l'✓ST .c..·. LED A f/,t'l.~ll)UIJ or= -~V.'D FE~T (2') 1~~.s1Di:::. Tf---E PRC~EP.TY l.lr.:E: . T ·, ;= c. -· r-,_.~. ·., ~' .... . ~[ ~ :-_t.,:.:_ ~ ~: -· ~ [ := .. C..~ :::·. F.J...SS \'-.':TH SOL._; C ~. ,_:,:.' t~I S C:; ~-Hf~ f.t :. C: ~ k'.V~ T E-[ :...::::::::: BE.,..., \'E CJ✓ -~~ '! ~ . : 7 J--.~-~ [· e.:: :=,~,F-:_(Wv kSS'. __ ,...;L.. Y ~ .:~·r.:c.~ _;ING ~HC '~1..,!,'.B~R C·\,'f:: Sr;'--"'T er.~ VAL VE, C )l.J'..JECT I0~-..J 1"'1US T f;:.f: I.-'.A[.".-E Wi-~ A COF'r' '-~ c-;; SF-it.::~s R:~·:: P :=..:. [: :..,,'sSS ~-=; rn::c '.if E ~:· 8C-1'.' ShJT cFi= v l•L \'E 1,,_ .'.._ f ,~.:::: F ;:.;::cEDE D sv A ·:.CF;:::=; OR s:= . ..c.,ss N1?:-, _E .A:": c::::. A ~ ::;.;_;s L \1,,~,, ;-.. :·.~ c:· r.1 _ ~ ct: 1.1.;..DE c:: :.o:. ... Fi--1:::1EVI L::½~ "T"~~. l'"i.4.T THE t<::: 110:.~ CF THE EA.CKFLC ,'/ ASSEl✓,E-L Y IS T~VEL \'E l'·,'2'··,ES , -, 2": TOP.: ;F'f-SIX :1~~--~ ~ S (J~ ... ,, hDO'v'E GF.t,DE i:, ,.,J..: /-.,-;;;,c._p, NO' SU3JECTEDTO f=c..OOCl~JG )-\._·,._t_;"Jn·/.,,3 ~,-,__: ~~._,:.•=:_:..,: .'/0 .. 17 '--" ~ ::.~F ·v;...LVE .i"'"'lt_ COi ~~f:CliON r~L-'ST 8E Mt.DE \\'I fH A C0~:0 Eh OR 3P .. l..S~ iJ [. ~:,_-::i::.:~f: t:~t<>V, 10 A ( 2-,-";-_ k G., E ".'-'.;S 0 ~ [:EG9 c ': El 80V, SHU, OFF \I Al VE l~AY BE FOl '. OV:: ~ SY A C-GPPER OR 6".ASS 'IIPPL!' ANu•:::;R A E;;ASS UN-Gr,. ·· -''"' '-·: •.. :,: T BL '.'. ·-.~= C·' S'.Jr-:=-c: =.0<:' LE~~G~ ,; -:7--!Ai ~•-ff BOT;cr.~ c :-= i;-' E c::;cKr-L.C',\' _Assc r,~~._ Y 1s -v>'E~ \':: :\1C~L $ 1 ;;··. 1 o-:-~ ::iTv -six '.'>-=-~ ):-; A8(Vt:. GF,;Jt'. 1r, f.:..'v. ;..-=:Et!. NOl SUB...1~CTED TO FLOOC<:JG .'. '.'"',{>· ·:=•,Y ,!.':;<,,~1/2; Y :s ·ro SF-I~~::-: 'ALLEO 0>.J A SLOPE \\.'ITf-'. A r1c;::c1zc,r-JTAL. TO \/Ef-{TICA~ R.AilC1 OF 4 1 Oh GRf::.h :c::: .. A T/,·'D f-OC·i t2') ,. .. _:~ ~ t: I~-.• ;ii\•..;\' "Le..; ·~,u I '--,JL ~-L_.;l_ J ~.;_,;:::,;:;,_J..,Ji',:G,,~G T1·1c. K,.,S:.. :,.,2 .... i. ;, '"',:,L;,.-:=,L'( :/,1..-~-i" u:.= L..0(.ft.~ l:: .:...: ;,.:~ ;...,':, =.J-, r·..i:J: ,::.,,_, i:.,::::.v T --:-o L ·, ;' r.~ (c·,:_ v ~r--,::_ c..;E~ _,c:::c· ~:;: .. ~$SU;:.~ F9"·t:.:F·LE Sl1CY.~~O,'✓ :->hEVE 1~·11C1N t.S:Sl'.:t.~E~!:::S ·,,\'L..nCl-i H.AVE EH:1\l A.~PF-:C;\iCD BY Tl·.E Sft--.TE Qt ·. ·-., -cL:·•,,':t.. Off-' -.1~. 1,t1::.\1T oc -:~_!.,_ H SLPV!Cf... ,.,,,.c:y (;;~, -s~D UN ,·.-.A.1::.P s::::=.v:cts ""~'iTHiN T~E ChRLS3,t..o r1::_,:'\;1c:~t..'_ ·/.,;-;-1::::-:;: .:,:.. -:-=;icT. 0 A 0 ~R()VED 8ACt<FLOW---------_ A S S E t; 8 L Y W ; 8 A L L V A L V E MINIMUM 3 6 • ,; A X I M U M ! ''Bl\CKFLOW ASSEML Y DEVICE -"'-~------------------'---- NOT TO SCALE HEAD ON RISER E 6" MIN C {2) GAL V. BANOS "FAST-LOCK" OR EQUAL PVC STREET El L ~--'---MARL'::X STREET ELL HOSE BIBB / C -------~-----2 /,' (5~ -COl-£::R ?Ve St.:eeve. MANUA.1-CGllRr:JL ANGL...E. 1/,A,.L.ve ~ . JlmDi-------d --~~~rrF-J i PVc AFe -~~ L[ -_-__ pvc FIFE P/SFR (~ S=~) DETAIL MANUAL CONTROL VALVE VALVE BOX WITH COVER MARKED "GV' (BROOKS MODEL • 3--Hl IN MEDIA.NS. BROOKS MODEL _.1'419 WITH SNAP COVER ELSEWHERE) 1/2' r,i TURF AND 2' r,i GROUNDCOVER AREAS PVC M"-"1~-c- (COYER AS NOTE It-I LEGEND) , ' 1 CU.FT. PEA GRAVEL~-~- PVC MA.LE ADAPTER NOTE: USE 4s°ELLS MMEDLATELY OOTSOE OF VALVE BOX, AS NECESSARY, FOR TRANSITON TO REOURED MANLf~E DC.PTH. F PRES3URE REGULA TING VALVE "AS BUil T" .APPF~'.J VED FOR PLl1.NTING A.ND IRFzIG1-\1'10N ONLY, INCLUDING PRECISI~ LOCA1'IO1'~ OF' PL"c\NTINC; RCE ___ EX:P. ___ _ APPROVED REVIEWED BY: ENGINEERING PLANCHECKER DATE t. RH' 11 S "I.. 1.L, lei. . INSPECTOR 0 "TE 1111 TIAI. ENGINEU< Of ~ REVISION DESCRIPTION D'-TE INITIAi. 0 A TE INIT1"1. QTY APPROVAi. DWN BY: __ _ CHKO BY: __ _ RVWO BY: DATE DATE -· ~~S~--.~lll--·-,rl.!'c'.~:':iiiie':"""'-,_llllll!_a~--------•1---------------------••-------r•-------------------.,.;;iiiiii'iia--------------------------------------------l!'.il! _______________________________ .. ,1, M[S.,O BLUf.Prll~l t/2" t-1 T1.JRF NO 2• '!'I C'R0t1 !DC-OVER A.r-:FJ..S --- FINISH "'R."-D!: S-01£NOO ACTUATED Pr.MOTE CONT~OL '/,'-!._VE RA SEAL RIMP $PUCES LA TC:RAL LtiE (COVER AS NOTED t-1 LEGEND 2"l<4"1<24' RED•\'000 ......_,...._6 ~N WRE (PROVDE 24" OF WRE f-1 A COL) C0••1,1.,~~, ,r:--•i-s, --...,, ,,, . ..,.. r ,-v-rw ¥,hcS O :;- -~ ,~ . ,.:. _'. 1 ~ -• ·'I 1 )VER "-' s ~0. LfC!END SCH 80 PVC Nlf>PLE • IJ;;;:: 4 "'r;:u_s ,.:/E".MTELY WfSOE OF VALVE BOX,AS NECES-SAR :7'.)R ·, ANSTT):)N TO REOUREO LA TEML LNE DEPTH. L REMOTE CONTROL VAL VE ~ --j'-. TO SYSTEM I I -.. PRESSURE REGULATOR SEE DETAIL _ __cF __ ~-BACKFLOVV PREVENTER SEE DETAIL D. EQUIPMENT ARRANGEMENT FOR ---------------------------- P.0.C. ,l\ T RESIDENTIAL LOTS ' 0)( ' ROUND PLASTIC VA WITH COVER ·ocv· KEO ~-,,,'1"'.L:/4;/4 QUICK COUPl_!NG VA ( ACME Tl !READ A BED COVER FOR ~ .. ,..~----"~t -" ,(« RE CLAIM ED WA TEl::n--~_,.___,. PVC MAIN (COVER AS NOTED IN LEGEND) SCH 80 PVC TEE OR ELL (3LIP X SUP X SLF) :,OLVENT WELD ANUFACTU8ED BY DURA, EN COMPONENT FACTORY 1 /2' IN TURF AND GROUND COVER 4• MAX. ,, ,,,, ¾;,;:· if1' ~--,, STAINLESS STEEL CL,l.MPS SOLVENT WELD 6. MIN. ,l.SSEMBLED SWING JOINT, MODEL .-010-2-4 Ii QUICK COUPLER VAL VE (non-potable) CONDUIT WIRE RUN PULL Box----- _,,,./ 1 8 • ---- PLAN VIEW • ="' ~ UN RTARED ICK FOUNDATION 00 •, __ ____......--LOOP CONTROL WIRES INTO PUll BOX. ALL SPLICES ARE TO BE MADE IN PULL BOXES OF1 REMOTE CONTROL VALVE BOXES. NOTES . -·7 I /--------,L, P....-+------\ '-----+ . --.J INSTALL PUL OXES AS SHOWN ON PLAN -BEDDING MATF.RIAL 2 AT JUNCTI S WH:CRE RUNS COMBINE:, SPLICE COMMON GROUND PULL BOX. 3_ Pi;LL BO OVF.R SHAU_ BE PERMANENTLY MARKED "ELECTRIC" 4. COND TORS f'OR EACH CONTROLLER CLOCK SHALL BE HARNESSED SEP ATEL Y AND AT SUFFICiENT INTERVALS TO MAl'1TA:N A DEFINi;E BU 5 Al -SPLICES SHALL BE MADE WITH A PROPERLY SET MECHANICAL SPLICE NNECTOR ENTIRELY ENCLOSED IN SELF-CURING RESIN ANC SHALL flE COMPLETELY WATER PROOF ALL SPARE WIRE [NDS SHALL BE INSULATED IN THE; SAME MANNER AS WIRE SPLICES 7. IF SPFCIFIED. All SPLICES SHALL BE SOLC[RED WITH METALLIC ALLOY SOI_OER PRIClfi TO INSTALLING CONNECTORS. S Wll~E BLNDLES INSIDE PULL BOXES SHALL BE AT LEAST 4 INCHES F'lCM THE UNDERSIOE OF THE BOX COVER MINIMUM SIZE PULL BOX SHALL BE AS SHOWN ABOVE. LARGER BQXFS MAY RE NECESSARY TO MEET 4" CLEARANCE REQUIREMENT. J ELECTRICAL PULL BOX SECTION EJE'.NDS, TEES, B CROSSES s" 1211 10" 16" . 20" 12 e" 10'1 12" 14" 16" 4::,• Bonda A B 4" 5" s" e" a" 10" · 10· 1211 12" 14" A~-i----A TEES 22 8Mds A B 2" 6" -· 3" B " ::.· 9• 5' 10 s· I I" 6" Min. Tee1 A B 5" 6 n . a· 6 9" 12' l j • l <1" 14" 16 CROSSES Undl,turbed Ground Copa C D e·· 14" to'' ~ i:1 ::: 12" 1;;-'. ~v+'' I \" -41 K DETAIL THRUST BLOCK .i-\.P 1=-> F( 0 \7EI) F'OR PL,i1.NTINC~ lF\:<IC~1-\'rT01\T _ONLY, "AS BUiL T" /\I\!D INC L,LJ D II\I C 1=-> REC rs fi; RCE ___ EXP. ___ _ DATE APPROVED L/JC.c\'rICJN CJF'. T)L:\N'flNG REVIEW[D BY: ENGINE;EFl!NG PLANCHECKER DATE INSPECTOR DATE l----+---+-----------+---t---"--+---t-------1 I SH~T I CITY OF CARL..SBA.D :.==o=::::'....'.====::::P::LA:::N:::N:::t:::N:::G==D=E=P::A::R=TM::E:::N=T_;_ Em ; LANDSCAPE IMPROVEMEl\i r FOR: : PLANNING AREA 27 AVIARA PHASE II Fourth Averiue Corpor~\e Centnr 1-----+---+------------------+---+---+-----t---"1 1551 Fourth Av!"!nue/Suile 200 San Oiegc, CA gJ 101 APP ~ ASS! DATE Landscape Architt>e:lure • Pi,:mning fF 9/--03:2 DA n: HllV,L ENGIN!IR Of WORK REVISION DESCRIPTION OWN BY: __ PROJECT NO. j ~&AD-DATt INITIAi. O.t.IT INITIAi. CHKD BY: CT-9:)-31'- OlHER APPROVAi. OTY N>Pf<OVAJ.. RVWD BY: SEE LANDSCAPE IMPROVEMENT DRAWINGS FOR CARLSBAD TRACT NO. 89-37 AVIARA PHASE II FOR EXISTING rgosCAPE SEE SHEET DRAWING E•\105594 \G3 1 • ~ 40' NUMBER 318-9L ' I ' , ' I \ .. C ,. ','" '1 I ' I I \ ,'--\ -I / I ' ' ' ' '' i 'I ' ' \ ' i' I \ C ' \ i ! '1: I i I \ \ ' I, \ \ '·, , ./. ,. ' " -· " \ \ i .- \ -~~=----_-" _______ _ 1=71mf/Gr J>1,,lJNL!/Je -1, ;,..//?es ~r; ;v ~ .' \ \ \ _.,..--· \ j \ ' I --__ ,,....__~_ ~ _,/ . . ' ' / Id ; I U I 1 \ ------. ', ' \ \ \··· I I I I \ ' ' I ' I \ ' \ \ \ /,:'I I I' ~ i l i I ,, I , ' \ \ / ,, J I • 11::6: t, 12.0 \ '· < DEL., .&L.e, IZ'ci::.. 40% G~, Sfl.,. ~T l2'a: <.co% M-2-v. t-tco. I£ 'cc /,-//" //" ' / \ ,, \, ·- / ! 1)/ / /;/ :>--~---SEELANDSCAPEIMPROVLMENT DRAWINGS FOR CARLSBAD TRACT NO. 89-37 AVIARA PHASE II FOR EXISTING ~DSCAPE SEE SHEET~_,__ DRAWING NUMBER 318 9L ,/' I iJ I , iJ -, / / / / / / Key NOTE: STREET iTREES WILL BE REQ_ UIRED PER P. C. RESO #3324, CONDITION #16 At'f(J !'):HALL BE INSTALLED BY GUEST bL/ILP~ .' ,,,_ _....,..,_ ___ _,_ ______ SEELANDSCAPEIMPROVEMENT \,, ,>'{ ,, / ! v( I I Fourtti ,A1,18nue Ci,rporate Center 1551 Fourth Avenue/Suite 200 San Diego, CA 92701 (619) 239-2450/FAX 239-0107 Landscape Architecture • Planning =If'-q/-O'?:>Z Al-'l.,1\U\/LU LNGINLGHNG PLI\NCHLGl<[H DRAWINGS FOR CARLSBAD TRACT NO. 89-37 AVIARA PHASE II FOR EXISTING L..t;-f'J.DSCAPE D/\Tl SEE SHEET _:.:tt__ DRAWING NUMBER 318-9L 40' o· 40· 80' 120' ------GRAPHIC SCALE: 1"=40' PLANTING PLAN HAS BUIL TH RCE ____ _ EXP _________ _ D<\ 11 INSP[CHJR DA Ii _:-_=-: _: _ _=: ~--+-----[ SH~ET 1 l CITY OF-CARLSBAD I ["HTf-i';! -+----1 __ '=? _ _ ___ _ PLANNING __ D_EP_~~-T!".1~NT __ 11: __ ~ -·--·--· .. -·---· ' '"''' ' ---·--··-·--·---------1 ---11 LANDSCAPE IMPROVEMENTS FOR: PLANNING AREA 27 IARA PHASE II ...... DAfF INliAI DATE i\llTIAI. [s..J:;1r-.r·rR ()I' WORK REVISION DESCRIPTION ·• u. WT 1.00 ~.A-L.. ANS ta-.A.L,f, 121 b:;:_ -4o% ~ C;;fAZ ,s-,,_, 'o, 1 1£' cc u;0% l~N... P...Pc, HCO. 12~, ·' C /,(} f' ,'/ SEE LANDSCAPE IMPROVEMENT--------,, DRAWINGS FOR CARLSBAD TRACT E•\!C6594 \G4 1 • -::;: 40' NO. 89-37 AV/ARA PHASE II FOR EXISTING LANDSCAPE SEE SHEET &:, DRAWING ,NUMBER 318-9L I . ' l I i \ \ \ \\ \ \ ( \ I \ \ I I I I I I I \ I . ,, ___ r\ ~v <-,~ \ / ,./ / -z_ -z_ )/ ---s- \ ' ' ' ' \ . /,()[ 1 I ' . 1. ! () 1' I :i • I I '.j ~ ~ ; I I I I ___,......,.... __ . SE~le.ANDSCAP E IM PROVEl\,jENT---------.... \ ' I \ I .. ·\ I I I I " " , .. DRAWINGS FOR CARLS6AD fRACT f NO. 89-37 AVIARA PHASE II FOR . . . EXISTING LANDSCAPE ·'1SE:ESl=IEEf '55 DRAWING ' ' NUMBER 31 B-9L • • /,()/' 1 ?' • • • • • • • • • • • • • • • • • • • • • • • • ' . ' ' f, • • • • ' • • I.Of' IH • • • • f{) '/' 11; \ I I \ I I \ ~ I ' -.,,. LOT 19 \ 'A'J 5 ) \ / •• . " ..... ...... ;'()l ,'f," I.UT ;;() • • •• ...... • • • • • .----- ' I - • •• • ••• . . "' ... • • • • • • • • • • .. ,,. ' • • • • • / I O I ' I \ ) I I I I / ) I ,, I _, ; I / • '-----SEE LANDSCAPE IMPROVEMENT DRAWINGS FOR CARLSBAD TRACT NO. 89-37 AVIARA PHASE II FOR EXISTING LANDSCAPE SEE SHEET ;;,5 DRAWING NUMBER 318-9L I\PPROVED ENGINEERING PLANCHECKER DI\TE I----+---+----------------- 1-------+---f---------------- Fourth Avenue Corporate Ceriter t-------+--t------------ 1551 Fourth Avenue/Suite 200 ~~ San DiaQo, CA 92"101 (619) 239·2450/ FAX 239-0107 \ 'I ,, 1. 2. \ I \ \ \ \, \ ' ---! I / NOTE: --I I ' \ \ \ \ \ \ \ __ .. ---· ----- Key Map·_ CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPLACEMENT OF EXISTING PLANT MATERIAL ON SLOPES DUE TO DAMAGE DURING THE GRADING PROCESS_ THIS INCLUDES TREES, SHRUBS, GROUNDCOVER AND HYDROSEED MIX. STREET TREES WILL BE REQUIRED PER P. C. RESO #3324, CONDITION #16 AND SHALL BE INSTALLED BY GUEST tu I U::.,LR.. $'-L.. -I ____,_?++_;___LI ·.....:..I +-J_r:"'--, -- . ----""'"" ----- ➔--------+--·"""" __ ,, __ _ -· ____ ,,,, _______ _____, ___ --·-·-··-···· . ------.. ------ +--~-----------··-···-·- -t-----+--···-· ·--···--· ---+---+---- 40' o· 40' 80' 120' _ .......... --.__.....,_------~ GRAPHIC SCALE: 1"' ~40' PLANTING PLAN HAS BUIL TH RC[__ IXP, DATE INSPEC'OR DA 'f SI I[[ T 10 CITY OF CARLSBAD ENGINEERING DEPARTMENT LANDSCAPE IMPROVEMENTS FOR: PLANNING AREA 27 IAR P SE II I------+--------. ""'" ... ,. -· ....... , ... _______ --+--- I APPR I ASSI_ andscape Architecture • Planning .. ----. ----------+------+-- ~1~ _--J d;o:b~ Ng,\ ] ¥~:~r] ENGINEER OF" WORK REVISION DESCRIPTION JA l!'" INIT AL □ T '--1E_ R APPR[JVAL DATE INl-!AL CITr ,c.,:i:i:::ovAL . . I ~ LANDSCAPING PART I -GENERAL 1.1 SUMMARY: THE WORK INCLUDES ALL SERVICES, LABOR, MATERIALS, TRANSPORTATION AND EQUIPMENT NECESSARY TO PERFORM THE WORK INDIC ... TED ON THE DRAWINGS AND AS SPECIFIED. · 1 R E L AT E D .)'r'..QBK; IRRIGATION SECTION 02441 1.2. SUBMITTAL$: UPON BEING AWARDED THE PROJECT, CONTRACTOR SHALL SUBMIT A LIST OF SOIL MIIENOMENTS, FERTILIZERS, PLANT MATERIALS, SEEDS, AND SOD WITH QUANTITIES OF E ... CH WITHIN 15 DAYS FROM AWARD OF CONTRACT. 1 .3, GU,._R ... NTEES AND REPLACEMENTS: . 1 SHRUBS, VINES ANO GROUNDCOVERS $HALL BE GUARANTEED TO REMAIN rlE ... LTHY AND VIGOROUSL Y GROWING FOR ONE GROWING SEASON OR SIXTY (60) D"YS, WHICHEVER COMES FIRST. . 2 ALL TREES THAT HAVE BEEN SUPPLIED AND INSTALLED UNDER THIS CONTRACT SHALL 8E GUARANTEED TO LIVE IN A HEAL THY CONDITION FOR A PERIOD OF ONE (1) YEAR FROM DATE OF FINAL ACCEPTANCE OF PROJECT IF TREES ARE ALSO SUPPLIED BY '(HE OWNER, THE GUARANTEE SHALL APPLY A$ STATED ABOVE . 3 ALL PL ... NTS FOUND TO BE DEAD AND ALL PLANTS NOT IN A VIGOROUS CONDITION NOTED WITHIN THE GUARANTEE PERIOD $HALL llE REPLACED WITHIN FOURTEEN (14) DAYS ,4 PL"NTS USED FOR REPL"CEMENT SHALL BE THE SAME KIND AND SIZE AS SPECIFIED IN THE PLANT LIST. THEY SHALL BE FURNISHED, PLANTED AND FERTILIZED AS ORIGINALLY SPECIFIED, AT NO COST TO OWNER 14 OllSERVATION. . 1 OBSERVATIONS HEREIN SPECIFIED SHALL 8E MADE BY THE .10 ', 1 .12 REJECTION ANO SUl:lSTITUTJON A. ALL PLANTS NOT CONFORMING TO THE REQUIREMENTS HEREIN SPECIFIED SHALL BE CONSIDERED DEFECTIVE, AND SUCH PLANTS, WHETHER IN PLACE OR NOT, SHALL IIE MARKED AS REJECTED AND BE IMMEDIATELY REMOVED FRO~ THE SITE OF THE WORK AND REPLACED WITH ACCEPTABLE PLANT MATERIALS. THE PLANT .. ATERIALS SHALL MEET ALL APPLICABLE INSPECTIONS REOUIRED BY L"W. ALL PLANTS SHALL BE OF THE SPECIES, VARIETY, SIZE, "GE, FLOWER COLOR "ND CONDITION AS SPECIFIED HEREIN "NDIQR AS INDICATED ON THE DRAWINGS. UNDER NO CONDITION WILL THERE BE ANY SUBSTITUTION OF PLANT SPECIES, VARIETY, OR REDUCED SIZE FOR THOSE LISTED ON THE ACCOMPANYING DRAWINCiS, EXCEPT WITH THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. VTfl !TIES A. ALL UTIUTIES (WATER AND ELECTRICITY) USED DURING THl INSTALLATION OF THE LANDSCAPING "ND IRRIGATION SYSTEMS FOR THIS PROJECT SHAU IIE PAID FOR IV THE CONTRACTOR. DURING THE 1,0,D•Y l,IAINTENANCE PERIOD, THE OWNER 5HALL 8E RESPONSIBLE FOR PAYl'E-.T OF THE UTILITIES. fB.OIECHON Of EXJST!NG TREES SHRUBS ANll VINES A. IT IS TI-IE INTENT OF THE PROJECT THAT CERTAIN EXISTING PLANT MATERIALS SHALL 8E RETAINED. PRIOR TO 1·HE RElolOVAL OF ANY TREES, THE CONTRACTOR SH"LL CONFER WITH THE ARCHITECT TO DETERMINE THOSE PLANTS THAT ARE TO REMAIN. B. All EXISTING TREES WHICH ARE TO REMAII-I IN THE PROJECT SHALL IIE T"GGEO AND IDENTIFIED IY THE CONTRACTOR PRIOR TD START OF WORK. C. CONTRACTOR SHALL BE RESP0NSl8LE FOR ALL TREES THAT ARE TO REMAIN IN THE PROJECT. DAMAGE TO A PLANT WHICH RESUL1'S IN DE ... TH OR PERt.lANENT DISFIGURATION SHAU RESULT IN THE COMPLETE REl,,IOVAL OF THE PLANT, INCLUDING ROOTS, FROM THE SITE BY THE CONTRACTOR; AND THE CONTRACTOR, AT HIS OWN EXPENSE SH.lLL REPL"CE THE PL"NT WITH ONE OF EOU"L VALUE AS ESTABLISHED BY THE ARCHITECT, OR REIMllURSE THE OWNEl'I THE COST OF SAID REPLACEMENT. THE ARCHITECT SHALL IE THE SOLE JUDGE OF THE COIWITIQN OF THE PLANT. D. All EXISTING TREES THAT ARE 10 REMAIN SHALL IIE PROTECTED AT ALL TIMES FROM DAM•GE IIY WORl(ERS ANO EQUIPMENT. ALL DAMAGE IIY THE CONTRACTOR TO EXISTING PLANTS SHALL BE REPAIRED AT THEIR EXPENSE BY PERSONNEL APPROVED IIY THE ARCHITECT - , 8, ARCHITECT. THE CONTRACTOR SHALL REQUEST OBSERVATION IN WRITING, 1H ADVANCE OF THE Tl"1E OBSERVATION IS REQUIRED. .? OBSERVATION WILL BE REQUIRED FOR THE FOLLOWING PARTS OF THE WORK: A, PRE-CONSTRUCTION MEETING. B. INCORPORATION OF SOIL CONDITIONERS AND FERTILIZERS INTO THE SOIL. C. UPON THE COMPLETION OF GR.DING PRIOR TO PLANTING. D. APPROVAL OF PL ... NT MATERIALS. E. WHEN TREES AND SHRUBS ARE SPOTTED IN PLACE FOR PL ... NTING, BUT BEFORE PLANTING HOLES ARE EXCAVATED. F, ORIENTING SPECIFIED TREES. G. VERIFICATION Of FINISH GRADES, H. APPLICATION OF PRE-EMERGENT HERBICIDE. I. PRE·MAINTENANCE OBSERVATION. J WHEN PLANTING, ANO ALL OTHER INDIC,lTED OR SPECIFIED WORI(, EXCEPT THE MAINTENANCE PERIOD, HAS BEEN COMPLETED, ACCEPTANCE AND WRITTEN APPROVAL SH ... LL ESTABLISH BEGINNING OF THE MAINTENANCE PERIOO. THIS IS NOT A FINAL OBSERVATION OR ACCEPTANCE, AND IT DOES NOT RELIEVE THE CONTRACTOR FROM ANY OF THE RESPONSIBILITIES IN THE CONTRACT DOCUMENTS FOR THIS PROJECT K · ~SERVATfON TO BE; HELD AT THE COMPLETION OF THE 60-DAY .. AINTENANCE PERIOD THIS OBSERVATION SHALL ESTABLISH THE BEGINNING DATE FOR THE ONE-YE,._R GUARANTEE OF ALL TREES ACCEPTANCE UPON COi.lPLETION OF THE FINAL OBSERVATION AND THE WORK OF THIS SECTION, THE CONTRACTOR WILL BE NOTIFIED IN WRITING, (1) WHETHER THE WORK IS ACCEPTABLE· AND (2) OF ANY REQUIREMENTS NECESSARY FOR COMPLETION AND ACCEPTANCE. · 4 THE CONTRACTOR OR HIS AUTHORIZED REPRESENTATIVE SHALL BE ON THE SITE AT THE TIME OF EACH OBSERVATION. MAINTENANCE; , 1 THE MAINTENANCE PERIOD BEGINS ON THE FIRST DAY AFTER ALL LANDSCAPE IRRIG.lTION WORK ON THIS PROJECT IS COMPLETED CHECKED, ACCEPTED, AND WRITTEN APPROVAL FROM TH~ ARCHITECT IS GIVEN TO BEGIN THE MAINTENANCE PERIOD, AND E. THE CONTRACTOR SH .. LL INSURE THAT MO FOREIGN M.lTERIAL ANDtOR LIQUID SUCH "5 PAINT CONCRETE CE .. ENT, OIL, TURPENTINE, ACID OR THE LIKE, IIE DEPOSITED OR ALLOWED TO IIE DEPOSITED ON ANY SOIL WITHIN THE DRIP LINE (THE OUTSIDE EDGE OF THE FOLIAGE OVERHANG) OF ANY TREE OR SHRUB, OR WITHIN 5· OF THE TRUNI( OF A VINE SHOULD ANY SUCH POISONING OF THE SOIL OCCUR THE CONTRACTOR SH .. LL l'IE.,OVE S.llD SOIL AS DIRECTED BY THE ARCHITECT AND REPLACE WITH ACCEPTAl!LE SOIL AT NO EJPENSE TO THE OWNER F. EJCAVATION ADJACENT TO EXISTING TREES AND SHRUBS. WHEl'IE IT IS MECESS.lRY TD EXCAVATE IN CLOSE PROXIMITY TO EXISTING TREES AND SHRUBS. ALL POSSIBLE CAUTION SHALL IE EXERClliED TO AVOID INJUl'IY TO ROOTS AND TALON~ EXCAVATION CLOSE TO TREES SHALL IE BY HAND TUNNELING UNDER l'IOOTS 2• AND LARGER IN DIAMETER: CUTTING OF l'IOOH, r AND LARGER SHALL BE ONLY ON THE APPROVAL Of THE ARCHITECT. P'AINT CUT l'IOOTS WITHIN I• HOURS, WHERE THIS IS MOT POSSll!LE, KEEP THE SITE OF EXCAVATION ADJACENT TO THE Tl'IEE SHADED WITH MOIST BURLAP OR CANVAS. INVOICING OF PLANT .. ATEl'IIALS ANO SOIL PREPARATION AND SOIL PREP,.IIATION CONFORMANCE TEST: , 1 AFTEII INSTALLATION OF PLANT MATERIALS, IIUT PAIOR TO THE l'RE-M ... INTEN•NCE INSPECTION, THE ARCHITECT, WITH THE HERETOF0"1f 5PECIFIED SIGNED COPIES OF THE REOUIRED CERTIFICATES, TRIP SUPS AND INVOICES fOR THE PLANT MATEFIIAlS AND RELATED ITEMS, SHlLL INCLUDE SUCH .. ATERIAL COMPARING THE TOTAL AREA ANDtOR THE AMOUNTS SPECIFIED. If THE MINIMUI' AMOUNTS HAVE NOT IIEEN FURNISHED THE ARCHITECT WILL REQUIRE TtiE INSTALLJ.TION OF ADDITIONAL M" TE RIALS TO FULFILL THE l,IIINIMUM REQUIREMENTS SPECIFIED . 2 UPON DELIVERY Of l,,l•TERIALS ANDIOR COt,1PLETIO"' Of ALL SOIL CONDITIONING ANO GR.DING, IUT PRIOR TO INITl,.TING PLANTING OPERATIONS, THE ARCHITECT WITH THE HERETOFORE SPECIFIED SIGNED COPIES OF THE REQUIRED CERTIFICATES, TRIP SLIPS AND INVOICES· FOR SOIL PREPARATION ~l<TEl'll"LS, SHALL INVOICE SUCH MATERIAL, COMPARING THE TOTAL AREA OF EACH OPERATION. IF THE MINIMUM f\ATES OF APPLICATION HAVE NOT IEEN MET, THE ARC>ilTECT WILL REQUIRE THE DISTRIBUTION OF ADDITIONAL OUANTITtES OF THESE MATERIALS TO FULFILL THE l,,IINIMUM APPI.ICATION REQUIREMENTS SPECIFIED_ .3 A SAMPLE OF THE SOIL AMENDMENTS SHALL IIE DELIVERED 10 THE ARCHITECT WITHIN 15 OATS AFTER RECORDING OF THE CONTl'IACT FOR SU9MITTAL TO A TESTING LABORATORY. AFTER SOIL AMENDMENTS HAVE IIEEN THOROUGHLY MIXED INTO THE SITE RANDOM SAMPLES OF THE l,IIXED SOIL WILL IIE TAKEN JY ... T.ttE 1.7. -2 . 3 .5 SHALL CONTINUE THEREAFTER FOR NO LESS THAN 50 CALENDAR DAYS. THE CONTRACTOR SHALL CONTINUOUSLY MAINTAIN ALL INVOLVED AREAS OF THE CONTRACT DURING THE PROGRESS OF THE WORK AND DURING THE MAINTENANCE PERIOD UNTIL THE FINAL ACCEPTANCE OF THE WOl'IK. REGULAl'I PLANTING MAINTENANCE OPERATIONS SHALL BEGIN IMMEDIATELY AFTER EACH PLANT OR LAWN IS PLANTED PLANTS AND LAWNS SH ... LL BE KEPT IN A HEALTHY, GROWING CONDITION AND IN A VISUALLY PLEASING APPEARANCE BY WATERING PRUNING MOWING, ROLLING, TRIMMING, EDGING, FEl'ITILIZING R0E-STAKING' PEST AND DISEASE CONTROLLING, SPRAYING, WEEDING, CLEANING'. UP AND ANY OTHER NECESSARY OPERATION OF MAINTENANCE LANDSCAPE AREAS SHALL BE KEPT FREE OF WEEDS NOXIOUS GRASS, AND ALL OTHER UNDESIRED VEGETATIVE GROWTH AND DE BAI$. ALL PLANTS FOUND TOl BE DEAD OR IN AN IMPAIRED CONDITION SHALL BE REPLACED IMMEDIATELY WITHIN 3 DAYS SEE. DRAWING FOR POST-FEl'ITILIZATION {7-9-4) PROGRAM. , THE CONTRACT COMPLETION DATE OF THE CONTRACT MAINTENANCE PERIOD WILL BE EXTENDED, WHEN IN THE OPINION OF THE ARCHITECT, IMPROPER MAINTENANCE ANDtOR POSSIBLE POOR OR UNHEALTHY CONDITION OF PLANTED MATERIAL OR UN-ESTABLISHED NON-COVERING LAWNS ARE EVIDENT AT THE TERMINATION OF THE SCHEDULED MAINTENANCE PERIOD. THE CONTRACTOR SHALL B RESPONSIBLE FOR •DDITIONAL MAINTENANCE OF THE WORK AT N·5" CHANGE IN CONTRACT PRICE UNTIL ALL OF THE WORK 1$ COMPLETED AND ACCEPTABLE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAIIHAINING "DEOUATE PROTECTION OF THE AREAS DAMAGED AREAS SHALL BE REPAIRED IMMEDI ... TELY AT THE CONTRACTOR'S EXPENSE. LAYOUT OF WORK: THE CONTRACTOR SHALL EMPLOY, AT HIS OWN EXPENSE, A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR TO LAY OUT THE WORK OF THE PROJECT, TO ESTABLISH ALL REFERENCE POINTS SET FOR CONSTRUCTION AND THE CERTIFICATION OF FINISH GRADES WITH CIVIL ENGINEER DRAWINGS, GENERAL REQUIREMENTS: ' 1 • 2 .3 THE TERM "PLANTING AREA" SHALL MEAN ALL AREAS TO IIE PLANTED WITH TREES, SHRUBS, GROUNDCOVERS, SOD AND SEED. ACTUAL PLANTING SHALL BE PERFORMED DURING THOSE PERIODS WHEN WEATHER AND SOIL CONDITIONS ARE SUITABLE IN ACCORDANCE WITH LOCALLY ACCEPTED HORTICULTURAL PRACTICE. All ROCKS AND CLODS 1• OR LARGER, AND OTHER GROWTH OR ARCHITECT AND SU!!MITTED TO THE SOil LABORATORY FOR COMPARISON TO A CONTROL MIX.. COST OF Tl'IE ABOVE TESTING 9Y THE SOILS lAl!ORATORY SHALL BE BORNE BY THE CONTRACTOR. , 4 AFTER LEACHING OPERATION, FOUR SOIL S,._MPLES WILL BE TAKEN BY ARCHITECT AND SUBMITTED TO THE SOIL LABOR.TORY FOR TESTING OF ECE AND PH COST OF THE ABOVE TESTING BY THE SOILS LABORATORY SHALL llE BORNE BY THE CONTRACTOR PART 2 · PRODUCTS 2. 1 SOIL AMENDMENT AND FERTILIZER, . 1 SOIL CONDITIONER SHALL CONTAIN A SPECl"L ILEND OF Ol'lGANIC FRACTIONS TO SUPPLY SEVERAL OEGl'IEES OF IIREAKDOWN RATE WHICH LASTS UP TO 10 YEARS IN THE SOIL, .t, l'OF!TION OF INORG,.NIC Al,<ENDMENT THAT RESISTS FURTHER IREAKD0W"4 l'H OF S.5 Tu 6.5, SALINITY OF J.0, OIIGANIC MATTER (DFIY WEiGHT IIASIS) MORE TH,._N t0%, NON-IONIC WETTING AGENT AHO TOTAL NITROGEN CQo,TENT OF 0.5%. (lO ... MEX, WIL·GRO Liff FOREST HUMUS), • . J GYPSUM SHALL BE A COMMERCIALLY Pl'IOCE.SSED AND PACK ... GED GYPSUM (CASO 2H20) WITH MINl"1UM 10% GRADE CONTAINING 14% COMBINED SULFUR. .) IRON SULFATE (EXPRESSED AS METALLIC) ,,.,_ Of QUALITY APPROVED IIY ARCHITECT. , , 4 SULPHUR (SOIL) (ELEMENTAL) It% OF OUALITY APPFIOVED BY ARCHITECT. . 5 FERTILIZER (COMI.IERCIAL) SH"-LL 8E A COMIIINATION OF NATUR,._L ORGANIC AND INORGANIC GRANUL-.R FERTILrzERS FREE-FLOWING SUITABLE FOR APPLIC ... TION WITH APPROVED EQUIPMENT AND SHALL CONTAIN THE FOLLOWING MINIYUM AVAIL,.BLE PERCENTAGES BY WEIGHT OF PLANT FOOD: NITROGEN PHOSPHORIC ACID POTASH 1.0'1;. MINIMUM 10_0% MINIMUM 10.0% MINIMUI.I APPROVED ENGINEERING PLANCHECKlR DATt: '7 . I . I DEBRIS ACCUMULATED DURING THE DURATION OF THE PROJECT, SHALL BE REMOVED FROM THE SITE UNLESS SPECIFICALLY £)(EMPTED IN WRIT ING. PRIOR TO THE EXCAVATION FOR PLANTING OR PLACING OF PLANT MATERIALS, LOCATE ALL UNDEl'IGROUND UTILITY LINES STILL IN USE AND TAKE PROPER PRECAUTIONS TO AVOID DAMAGE TO SUCH IMPROVEMENTS. IN THE EVENT OF A CONFLICT BETWEEN SUCH LINES AND PLANT LOC,.TIONS, NOTIFY THE ARCHITECT WHO SHALL ARRANGE FOR THE RELOCATION OF ONE OR THE OTHER. THE CONTRACTOR ASSUl,IES ALL RESPONSIBILITY FOR MAKING ANY AND ALL REPAIRS FOR DAMAGES RESUl TING l'ROM WORK AS HEREIN SPECIFIED. GRADING ANO SOIL PREPARATION WORK SHALL BE PERFORMED ONLY DURING THE PERIOD WHEN BENEFICIAL ANO OPTI .. Ut,1 RESULTS MAY BE OBTAINED. IF THE MOISTURE CONTENT OF THE SOIL SHOULD REACH SUCH A LEVEL THAT WORKING IT WOULD DESTROY SOIL STRUCTURE, SPREADING AND GRADING OPERATIONS SHALL BE SUSPENDED UNTIL THE MOISTURE CONTENT IS INCREASED OR REDUCED TO •ccEPTA8LE LEVELS ANO THE DESIRED RESULTS ARE LIKELY TO BE OBTAINED. ALL SCALED DI .. ENSIONS ARE APPROXIM ... TE. BEFORE PROCEEDING WITH ANY WORK, CAREFULLY CHECK AND VERIFY ALL DIMENSIONS AND IMMEDIATELY INFORM THE ARCHITECT OF ANY DISCREPANCY BETWEEN THE DRAWINGS ANDIOR SPECIFIC,.TIONS AND ACTUAL CONDITIONS, QUANTITIES FOR PLANT MATERIALS ARE, SHOWN FOR CONVENIENCE ONLY, AND ARE NOT GUARANTEED. CHECK AND VERIFY COUNT AND SUPPLY SUFFICIENT NUMBER TO FULFILL INTENT OF DRAWINGS . ADEOU•TELY STAKE, BARRICADE, AND PROTECT ALL IRRIGATION EQUIPMENT, MANHOLES, UTILITY LINES, ANO OTHER EXISTING PROPERTY DUl'IING ALL PHASES OF THE SOIL AMENDING AND GRADING OPERATIONS. S£.ECIMEN TREE SELECTIQ.N.; A. ONE SAMPLE OF EACH Tl'IEE VARIETY AND SIZE, CALLED OUT ON DRAWINGS 15-GALLON AND LARGER SHALL IIE DELIVERED TO THE PROJECT SITE FOR APPROVAL PRIOR TO INSTALLATION. 8. THE CONTRACTOR SHALL IMMEDIATELY REMOVE ANY TREES NOT APPROVED. C. THE CONTRACTOR AT HIS OPTION AND AT HIS EXPENSE CAN RETAIN THE SERVICES OF THE ARCHITECT TO REVIEW TREES 24· BOX SllE AND LARGER TAGGED AT THE NURSERY AND/OR AT ITS PL.CE OF GROWTH, OR AS OTHERWISE SPECIFIED OH DR ... WINGS . . 6 FERTILIZER (COMMERCIAL) SHALL BE A LONG-LASTING CONTROLlED RELEASE PLASTIC·COATED, UNIFORM IN COMPOSITION, fl'IEE- FLOWING, SUITABLE FOR APPLICATION WITH APPROVED EQUIPMENT, AND SHALL CONTAIN THE FOLLOWING MIN1"1UM AVAILABLE PERCENTAGES IIY WEIGHT OF PLANT FOOD: NITROGEN PHOSPHORIC ACID POTASH 21-0% MINIMUM 00% MINIMUM 0.0% MINIMUM _ 7 FERTILIZER (COMMERCIAL) SHALL BE A LONG-LASTING CONTROLLED J-\PPE0\1ED F'OR PL/1,N'fINC~ 1\ND IRR IC; 1-\'I'IO N O NL 17 , li\!CLTJDINC; f)RF:CTSF, L,C)C;\TION OF' PLA_NTING .L'i.REA_S. "AS RC£-~-EXP. REYIEWEO 8Y: INSPECTOR BUil T" OATE, , -.-~~:::---.--------...,_~~+------=------+_:________+-+-t--1 LANDSCAPE IMPROVEMENTS FOR: PLANNING AREA 27 Fourth Aven1,1e Corporate Center t---➔----1--------------------1---+---+----I-----I 1551 Fourtti Avenm1/Suite 200 San Diego, CA 92101 (619) 239·2450/FAX 239-0107 Lar,d$C,1.~ Afchrtecture • Planning #21)--030 DATE N1\.ll RE\llstON DESCRIPTION VIARA PHASE II PRO.CCT NO GTSD-.3"-1-320-4 I ORAWINC NO_ ______ .... ___________________ ~ ______ ,._ _____ ....,._ ________ '::.~~~~~~~~~~~~~-.·--~ 01!0 /li'f'flOV-'L 2.2 2.3 2.4 RELEASE PLASTIC-COATED, UNIFORM IN COMPOSITION, FREE- FLOWING, SUITABLE FOR APPLICATION WITH APPROVED EQUIPMENT, ANO SHALL CONTAIN THE FOLLOWING MINIMUM AVAILABLE PERCENTAGES BY WEIGHT OF PLANT FOOD: NITROGEN PHOSPHORIC ACID POTASH 16.0% MINIMUM 20.0-,. MINIMUM 0.0% MINIMUM .8 FERTILIZER (COMMERCIAL) SHALL BE A COMBINATION OF NATURAL ORGANIC ANO INORGANIC GRANULAR FERTILIZERS, FREE·FLOWING, SUITABLE FOR APPLICATION WITH APPROVED EQUIPMENT, AND SHALL CONTAIN THE FOLLOWING MINIMUM AVAILABLE PERCENTAGES BY WEIGHT OF PLANT FOOO· NITROGEN PHOSPHORIC ACID POTASH 7.0% MINIMUM 9.0-,. MINIMUM 4.0% MINIMUM . 9 PLANTING TABLETS SHALL IIE TIGHTLY COMPRESSED CHIP TYPE COMMERCIAL GRADE PLANTING TABLETS. OF VARYING SIZES WITH THE FOLLOWING AVAILABLE PERCENTAGES BY WEIGHT OF PLANT FOOO: NITROGEN PHOSPHORIC ACID POTASH 20.0% MINIMUM 10.0% MINIMUM 5.0% MINIMUM . 1 0 SOIL ENHANCER SHALL BE SARVON. PLANTING BACKFILL: PLANTING BACKFILL IS PER THE SOIL TEST RECOMMENDATIONS ANO PLANTING BACKFILL SHALL BE A THOROUGHLY BLENDED MIXTURE OF EXISTING SITE SOIL AND SOIL AMENDMENTS AT THE FOLLOWING MIXTURE. SOIL CONDITIONER SITE SOIL IRON SULFATE GYPSUM STAKING MATERIALS· 114 CU. YD. 3;4 CU. YD. 1 LB.IPER CU YD. OF MIX 10 LBS 'PER CU YO OF MIX STAKES SHALL BE OF LOOGE POLE PINE. THESE SHALL BE STRAIGHT SHAFTS, SHAVED AND CUT CLEAN AND BARE OF BRANCHES AND STUBS. OF UNIFORM THICKNESS WITH A MINIMUM DIAMETER OF 2 INCHES, FREE OF LOOSE l(NOTS, SPLITS OR BENOS. STAKES SHALL BE NO LESS THAN TEN (10) FEET IN LENGTH. GUYING MATERIALS· . 1 GUY WIRES SHALL BE OF PL1AaLE, ZINC-COATED STEEL OF NO. 12 GAUGE. FOR TESTING SOIL TEST SHALL MEET THE FOLLOWING REQUIRE MEN TS· ECE PH MAXIMUM 3.0 X l0.3 MAXIMc!M 7 .5 A PERCENT OF ORGANIC MATTER SOIL TEST AFTER LEACHING MAY BE REQUIRED BY ARCHITECT. C RE-APPLICATION OF SOIL AMENDMENT AND LE-",CHING OPER .. Tl01' SHALL BE REPEATED BY CONTRACTOR IF TESTS SHOW A NEGATIVE RESULT. EXPENSE OF TEST, RE- APPLICATION OF A SOIL AMENDMENT ANO LEACHING OPE.RATION SHA\.L IIE BORNE BY COt;TRACTOR D. DEEP WATER LEACHING SHALL BE DONE PRIOR TO THE APPLICATION OF THE COMMERCIAL FERTH.IZER 1·10-10. L ND PLANTING SHALL BE INSTALLEC UNTIL APPROVAL HAS IIEEN GIVEN BY THE ARCHITECT IN WRlrlNG CARE SHALL BE TAl(EN THAT THE RAH OF APPLICI. TION or WATER DOES NOT CAUSE EROSION OR SLUfFING OF SOILS. . 5 ALL DEPRESSIONS, VOIDS, EROSION SCARS. AND SETTLED TRENCHES GENERATED BY THE DEEP WATERING SHALL SE FILLED WITH CONDITIOI\ED TOPSOIL AND BROUGHT TO FINISH GRADE. FINISH GRADING: . 1 FINISH GR.ADES SHALL IIE. AS INDICATED ON CIVIL ENGl>,[[R'S DRAWINGS. .2 FINISH GRADES SHALL BE !MEI.SURED AS THE FINAL WATER- COMPACTED AND SETTLED SURFACE GRADES AND SHALL IIE WITHIN PLUS OR MINUS O 1 FOOT OF THE SPOT ELEVATIONS AND GR4DE LINES INDICATED ON THE CIVIL ENGINEEll'S DRJ.\YlliG . 3 FINISH GRADES $HALL BE MEASURED AT THE TOP SURFACE OF SU Rf ACE M,t. TE RIALS. .• MOLDING ANO ROUNDING OF THE GR,1,DES SHALL BE PROVIDED AT ALL CHANGES IN SI.OPE. .5 ALL UNDULATIONS AND IRREGULMllTIES IN THE PL-.NTING SURFACES RESULTING FROM TILLAGE, ROTOTIL\.ING, AND ALL OTHER OPERATIONS, SHALL l!E LEVELED ANO f"LOATED OUT BEFORE PLANTING OPERATIONS ARE INITIATED. .6 THE CONTRACTOR SHALL TAKE EVEF\Y PRECAUTION TO PROTECT ANO AVOID DAMAGE TO SPRINKLER HE.,DS. IRRIGATION LINES, AND OTHER UNDERGROUND UTILITIES DURING GRADING AND CONDITIONING OPERATIONS. 3.5 . 2 ANCHORS (DEADMEN) FOR HOLDING GUY WIRES SHALL BE 4 INCHES X 4 INCHES OF SOLID LUMBER, 1' • 6' IN LENGTH. . 3 HOSE FOR COVERING WIRE SHALL BE OF 2-PLY REINFORCED RUBBER, USEO OR NEW, GARDEN HOSE TYPE OF AT LEAST 112 INCH IN DIAMETER. . 4 FLAGS, TO BE ATTACHED TO GUYS, SHALL BE OF SURGICAL TUBING 1/8 INCH IN DIAMETER AND FOUR FEET LONG, OF UNIFORi.i THICl(NESS. -5 TREE TIES SHALL BE BORDON CINCH-TIE OR APPROVED EOUAL. PLANT MATERIALS: • 1 NOMENCLATURE: THE SCIENTIFIC AND COMMON NAMES OF PLANTS HEREIN SPECIFIED CONFORM WITH THE APPROVED NAMES GIVEN IN "A CHECl(LIST OF WOODY ORNAMENTAL PLANTS OF CALIFORNIA", PUBLISHED BY THE UNIVERSITY OF CALIFORNIA, COLLEGE OF AGRICULTURE, MANUAL 32 (1963). SEE UST OF PLANT MATERIAL ON DRAWINGS . -2 DUALITY AND SIZE OF ALL PLANTS SHALL BE NO. 1, OF PINTO TAG STOCK. THEY SHALL BE VIGOROUS. OF NORMAL GROWTH, FREE FROM OISE ASE, INSECTS, INSECT EGGS, AND MEET OR EXCEED THE MEASUREMENTS SPECIFIED. PINTO TAGS MUST BE SUBMITTED TO THE ARCHITECT -3 CONTAINER STOCK (!,GALLON, 5-GA\.LON, 15-GALLON, AND BOX SIZES) SHAU. HAVE GROWN IN CONTAINERS FOR AT LEAST SIX MONTHS, IIUT NOT O>ER TWO YEARS. NO CONTAINED PLANTS THAT HAVE CRACKED OR BROKEN BALLS Of EARTH, WHEN TAl(EN FROM THE CONTAINER, SHALL BE PLANTED, EXCEPT UPON SPECIAL APPROVAL. NO TREES w,rH DAM,1,GED ROOTS OR BROKEN BALLS SHALL BE PLANTED. -4 PRUNING SHALL NOT BE DONE, PRIOR TO DELIVERY, EXCEPT BY WRITTEN APPROVAL FROM THE ARCHITECT . 5 INSPECTION OF PLANT MATERIALS. REQUIRED BY CITY, COUNTY OR STATE AUTHORITIES. SHALL BE A RESPONSIBILITY OF THE CONTRACTOR. ANO WHERE NECESSARY CONTRACTOR SHALL HAVE SECURED PERMITS OR CERTIFICATES PRIOR TO DELIVERY OF PLANTS TO SITE. -6 PLANTS SH-.Ll. BE SUBJECT TO INSPECTION, ANO APPROVAL OR REJECTION, AT THE PROJECT SITE AT ANY TIME BEFORE OR DURING PROGRESS OF WORI(, FOR SIZE, VARIETY, CONDITION, L.tTENT DEFECTS ANO INJURIES REJECTED PLANTS SHALL IIE REMOVED FROM THE PROJECT SITE IMMEDIATELY. . 7 SUBSTITUTIONS WILL NOT BE PERMITTED EXCEPT THAT IF PROOF IS SUBMITTED THAT ANY PLANT SPECIFIED IS NOT OBTAINABLE, A .7 FINAL FINISH GR4DES SHALL INSURE POSITIVE DRAINAGE OF THE SITE WITH ALL SURFACE DRAINAGE AWAY FROM BUILDINGS. WALLS. AND TOWJo.RD RD-.DW.HS. DRAINS, AND c-.TCH B.lSINS . ! FINAL GRADES SH.tLL BE ACCEPTABLE TO THE AACHITEC. BEFORE PL,l,NTlhG O•ERATIONS Will BE ALLOWED TO BEGIN. . ; PLANTING SURU,CES SHALL BE G'IAOED WiTH NO LESS THPI ONE (1) PERCENT SURFACE SLOP[ FOR POSITIVE DRAINAGE AWAY FROt.' ,'.LL BUIL01NG:i. . 1 THE LAYOUT or LOCATIONS FOR PLANTS AND OUTLINES OF GROUNDCOVER TO BE PLANTED SHALL IIE APPROVED ON THE SITE. IIY THE ARCHITECT, PRIOR TO THEIR PLANTING All SUCH LOC.tTIONS SHALL IE CHECKED fOR "0SSl8LE INTERFERENCE WIT" EXISTING UNDERGROUND PIPING. PRIOR TO EXCAVATION OF HOLES ff UNDERGROUND CONS1RUCTION OR UTILITY llNES MIE ENCOcJNTERED IN THE ElCAVATION 0' '°l"-NTING AREAS, OH<ER LOCA.TIONS FOR THE '°lUITING MAY I[ SELECTED IY THE ARCH!TECT DAMAGE TO EXISTING UTILITIES SH-.LL tt THE AESPQNSIIIILITY OF THE CONTRACTOR . ~ T.lli.G_Ifil.f...5....Jtlfi Il 5......Afil1 YIN ES A. ALL ExC-.VATED HOL[S IHAl.L HAVE VERTICAL SIDES w,TH AOUGHENED SURFACES AND SHALL BE Of THt MIN1"1U" SIZES INDICATED ON DRAWINGS HOLES SHALL IE.. IN ALL C•SES. LARG[ ENOUGH 10 P[R.,,T HANDLING ,t.,;D PLANTING WITHOUT INJURY Ofi Bl'IE.AKACE or f'IOOT ■ALLS OR l'IOOTI, B EXCAVATION StULL INCLUDE THE STF1rPPING AND STAl(INC Of ALL ACCE P14BLE SOIL E NCOUHTERED WITHIN Tl-<[ AREAS TO •E EXC.tVATED FOR ,-LANT "ITS ,t.NO PL-.NTINC BEDS PROTECT ALL ARt4S TH-.1 AA[ TO IE TRUCKED OVER ANO V~ON WHICH SOil IS TO IIE TUIIPORAAILY STAKED PENDING ITS "'E•USE FOR THE FILLING or HOLES. PITS. A'iO l!!EDS C EXCESS SOIL GENEl'l.tTED FROM THE PLANTING HOLES SHALL IE SPREAD ON TH( $1TE AS DIRECTED BY THE ARCHITECT D. PLANTS IN CAN CONTAINERS SHALL HAVE THE CANS OPENED Ill CUTTING YERTICJ.LLY ON OPPOSITE SIDES OF EACH C-.N WITH NURSERY CA>< OPENERS, TIN SNIPS, OR OTHER APPROVEO INSTRUMEN1S FOR THIS PURPOSE .ALL USED CANS SHALL l'IE REMOVED TO THE STORAGE AREA OR n10M THE SITE DAILY. E -THE PLANTS SHALL IIE PLANTED AT APPROVED l.OCATIONS WITH THE HERETOFORE SPECIFIED CONDITIONER AND SOIL Pl.ANTING BACKFILL. NO PLANT EXCEPl GROUNDCOVER SHALL II[ PLANTED WITHIN THREE (3) FEET Of sr,;INKLER Cl PROPOSAL Will 8E CONSIDERED FOR USE OF THE NEAREST EQUIVALENT SIZE, VARIETY AND COST. ALL SUBSTITUTIONS ARE SUBJECT TO ARCHITECT'S WRITTEN APPROVAL. .I QUANTITIES SHALL BE FURNISHED AS NEEDEO TO COMPLETE WORK SHOWN ON DRAWINGS. . t THE .ARCHITECT RESERVES THE RIGHT TO INSPECT ROOT CONDITION OF ANY SPECIES, PARTICULARLY THOSE GROWN FROM SEED, .ANO IF FOUND DEFECTIVE. TO REJECT THE PLANTS REPRESENTED IIY THE DEFECTIVE SAr.lPLE. .10 IDENTIFY PLANT SPECIES OR VARIETIES CORRECTLY ON LEGIBLE WEATHERPROOF LABELS ATTACHED SECURELY TO THE PLANT: THERE SHALL BE A MINIMUM OF ONE LABELED PLANT FOR EACH 5 PLANTS IN A LOT. . 11 HYDRO-SEED MIX AND MATERIALS SHALL BE AS CALLEO OUT ON DRAWINGS. . 1 t GAOUNDCOVEA PLANTS SHALi. BE HEALTHY, VIGOROUS ROOTED CUTTINGS GROWN IN fl.ATS UNTIL TRANSPLANTING. . 13 PRE-EMERGENT HERBICIDE SHALL BE SUR FLAN TREFLAN, DYMID OR EQUAL. • .1. WEED CONTACT SPRAY SHALL IIE ROUNDUP. f'.A_IJJ 3 · EXECUTION 3. 1 SITE PREPARATION AND WEED ABATEMENT: . 1 GRUB AND CLEAN PLANTING AREA, REMOVING DEBRIS ANO ROCK 4 ANO ERADICATING WEEDS. . 2 WEED ERADICATION SHALl SE DONE Tl;N (10) DAYS PRIOR TO COMMENCEMENT OF ANY PLANTING OR IRRIGATION WORK. 3.2 V.'EED ABATEMENT .1 UPON CO,..PLETION OF THE IRRIGATION SYSTEM AND AFTER DEBRIS. FIOC1'S AND EXISTING WEEDS AND GROWTH HAVE SEEN REMOVED FROM THE PLANTING AREA, APPLY 200 POUNDS OF COMMERCIAL FERTILIZER 21-0-0 PER .ACRE. . 2 WATER .tLL AREAS E\IERY DAY FOR iWENTY-ONE (21) CONSECUTIVE OAYS AND UNTIL WEEO SEEDS HAVE GERMINATED CE4SE WATERING FOR THREE (3) DAYS AND SPRAY NON-SELECTIVE HEF1BiCIDE "ROUNDUP-TO ERADICATE THE GERMINATED WEEDS TRI.NSLOCATION OR APPROVED PEFUOD SHOULD BE 7•10 DAYS. NOTE: HERBICIDE APPLICATOR SHALL BE LICENSED BY THE STATE OF CALIFORNIA. f. G. 11 I. J. K. L. HEADS NO TREE SHA~L llE PLANTED WITHIN SIX (6) FEET OF SPRIN~LER HEADS. THE PLA><TS SHALL llE PLACED Iii THE PLANTING PITS Oli THE BACl':FILL MATERIALS WHICH HAS SEEN HAND-TAMPED AND WATER HAS SETTLED TO THE ROOT ll4LL IIASE LEVELS PRIOR TO THE PLACEMENT OF THE PLANTS. AFTER SETTING THE PLANTS, THE REMAINING B;.CKFILL MATERIAL SHALi l!E CARUULLY TAMPED AND SETTLED AROUND EACH ROOT f!Al.L TO Fill -.LL VOIDS. E.ACti TREE AND SHRUB SH.llL IE PLACED IN THE CENTER Of TKE HOLE AND SHALL BE SET PLUMB AND HELD RIGIDLY IN POSITION UNTIL THE PLANTING l!!ACKFILL HAS IEEN TAMPED FROM AROUND EACH ROOT 60.L.L. ALL PLANTS $HALL BE SET AT SUCH A LEVEL THAT AFTER SETTLING, THEY IIEAR THE SAME IIELATIONSHIP TO THE SURROUNDING FINISH GR-.OE AS THEY ,oRE TO THE SOIL LINE GRADE IN THE CO>,TAINER. UNLESS OTHERWISE NOTED ,LANTING TABLETS SHALL aE ,L.ACED IN EACH ,LANTING HOLE AT TKE FOLLOWING IIATES: (1 )·S (1 ~21 (J,,21 (51-21 (1)·21 GRAM TABLET GRAM TABLET GRJ.M TAIILETS GRAM TABl.ETS GRAM TABLET PEA LINER AND FLAT SIZE ,LANT. PEA 1-GALLON CONTAINER. PEIi J,G-',LLON CONTJ.INEA. PEFI lS-GI\LlON CONTAINER PER EACH )" OF IOX &IZE. NO PLANT WILL IE ACCEPTED IF THE IIOOT IALL IS SAOKEN OR CRACKED, EITHER IEFORE, DURING OR .AFTER THE PROCESS OF INSTALLATION. ALL PLANTS SHALL aE THOROUGHLY WATERED IN TO THE FULL DEPTH OF EACH PLANTING HOLE IMMEDIATELY .AFTER ,-LANTING ALL TREES 15 GAL AND SMALLER SHALL BE STA!<ED WITH TWO LODGE POLE STAKES, DRIVEN INTO THE GROUND ON THE WINDWARD SIDE OF THE TREE. THE STAKES SHALL BE DRIVEN IN PLUMB AND SECURE SPECIAL CARE SHALL aE TAKEN THAT THE DRIVING IN OF THE STAKE DOES NOT DAMAGE THE TREE. ROOTS OR ROOT BALL TREE TIES SHALL IIE FASTENED TO EACH TREE AND STAKE BY LOOPING FIGURE 1·5 WITH THE INSIDE DI/I.METER OF THE TIE AT 2 OR 3 TIMES •n.LL ......... .,, ,,.\,..l'\.I ... U inc 11:1,,...,._,,.._ l,.,'f" it,'" IU ........ ■r'I~ ............ .__ (SEE DETAILED DRAWINGS.) ,........,, ~ ti F'"ourth Avenue Corporate Center ~ 1551 Fourth Avenu9/ Suite 200 l San Diego. CA 92101 '--' / \ (619) 239-2450/F"AX 239·0107 Landscape Ard,1tecture • P!anr1ir'l9 #-°:3r /--036 3.3 APPf10V[D • 3 RAKE ANO HAUL OFF ALL DEAD WEEDS TO 11? INCH BELOW THE SURFACE OF THE SOIL. .4 IF PERENNIAL WEi:DS OR GRASSES STllL EXIST. RE-WATER EVERY DAV FOR FOURTEEN (14) CONSECUTIVE DAYS, UNTIL THE NEW GROWTH APPEARS. RE-APPLY A NON SELECTIVE HERBICIDE. REMOVE WEEDS AFTER HERBICIDE HAS HAD A SUFFICIENT TIME TO 1(I1.L. SOIL. CONDITIONING, FERTILIZING .ANO ROTOTILLING: . 1 AFTER THE .AREAS HAVE BEEN DEEP RIPPED TO A DEPTH OF 8 INCHES, THE FOLLOWING RATES OF SOIL CONDITIONING AND AloAENOMEIH MATERIA\.S SHALL BE EVENLY SPREAD OVER All. PLANTING AREAS AND SHALL BE THOROUGHLY SCARIFIED TO AN AVERAGE DEPTH OF SIX INCHES BY ROTOTILllNG A MINIMUM OF TWO ALTERNATING PASSES. AMENDr.lENT MUST BE INTIMATELY IILENDED WITH SOIL. A . SO!L CONDITIONER SOIL SU\.PHUR IRON SULFATE GYPSUM 5 CU. YD. PER 1,000 SQ. FT. 10 LBS. PER 1,000 SO. FT. 20 LBS. PER 1,000 SQ. FT. 2S0 lllS. PER 1,000 SO. FT. RATE OF APPLICATION IS FOR BIDDING PURPOSES ONLY • SOIL TEST MAY REDUCE OR INCREASE TOTAL SOil. AMENDMENT YARDAGE ADJUSTMENTS (PLUS OR MINUS) MAY IIE NECESSARY. TrlE RESULTS ANO RECOr.lMENDATIONS OF THE SOIL TESTING L,t.BORATORY SHALL BE SUBMITTED TO ANO APPROVED BY THE CITY. B. FERTILIZER (COMMERCIAL): 1-10-10 SHALL IIE APPLIED AT THE RATE OF •O POUNDS PER 1,000 SQUARE FEET AND SCARIFIED INTO THE TOP TWO INCHES OF FINISH GRADE. FERTILIZER SHALL BE APPLIED AFTER LEACHING OPERATION C. SARVON SHALL BE APPLIED AT THE RATE OF 1 P:NT PER 1,000 SQUARE FEET. $ARVON SHALL BE APPLIED IN AREAS INDICATED SY NOTES ON THE DRAWING. . 2 _ THE THOROUGHNESS ,O,ND COMPLETENESS OF THE ROTOTILLING AND INCORPORATION OF THE SOIL CONDITIONERS/AMENDMENTS SHALL BE ACCEPTABLE TO THE ARCHITECT. FOR SLOPES 2:1 AND STEEPER, OR AS PER THE OR.tWINGS, OMIT SOIL CONDITIONER APPLICATION AND TILLING. . 3 DEEP WATER LEACHING; A. AFTER COMPl.ETE INSTALLATION AND TESTING OF THE IRRIGATION SYSTEM AND APPLICATION OF SOIL CONDITIONING, All AREAS SHALL BE DEEP WATER LEACHED AND COMPACTED ANO SETTLED BY CONTINUOUS APPLICATION OF IRRIGATION WATER UNTIL THE SOIL HAS RECEIVED A MINIMUM OF SIX INCHES OF WATER. 11. AFTER LEACHING OPERATION. FOUR SOIL SAMPLES SHALL BE TAl':EN BY ARCHITECT AND SUBMITTED TO SOIL LABORATORY N . THE DIAMETER OF THE TREE AND BY TACl<:ING THE IACK OF THE TIE TO THE STAl(E (SEE DETAILED DRAWINGS.) ALL SPECIMEN TREES 2~" aOX AND LARGER SHALL BE GUYED AS DETAILED THE STAKING ..,.ID GUYING SHALL BE ACCOMPLISHED IN SUCH A MAN>,[R AS TO INSURE THE PROPER AND HEAL THY GROWTH ANO SAFETY OF THE PLANTS. PROPERTY, AND THE PUBLIC. E:NGINEl::l'IING PLANCHcCKGl DAT[ D-.rr HTW. D4T£ INllW. "AS BUil T" RC£ ___ EXF. REVIEWED BY: INSPECTOR DATE LANDSCAPL:: IMPROVEMENTS FOR: PLANNING AREA 27 /?A VIARA. PHASE 11 APP'7);~%,' . 7. /J . '/.,, , , /J 7 2 /:9::;, -. , riio,,{N ING Ol R EC T ()If. DATE , REVISION DESCRIPTION Oll£R N'PROYAL QTY N'PROVAL Dlltl BY: -•--1 CHKO BY: ---1 R\IWD BY: ' ' -. .- ' - l\j .3 •• ,. LlolilCMk~ o. P. Q. R. THE . _CS)NTRACTOR SHALL BE RESPONSIBLE FOR ALL SURFffic AND SUBSURFACE DRAINAGE REQUIRED WHICH MAY AFFECT HIS GUARANTEE Of THE TREES, SHRUBS, AND VINES. PRUNING AFTER PLANTING SHALL BE REQUIRED ON ALL TREES, SHRUBS, AND VINES WHEN NECESSARY TO PROVIDE THE SPECIFIED OR •PPROVED STANDARD SHAPES, FORM AND/OR SIZES CHARACTERISTIC TO EACH PLANT. PRUNING MAY INCLUDE THINNING, TOPPING, AND/OR CUTTING AND SHALL BE UNDER THE DIRECTION OF THE ARCHITECT. CUTS OVER 3/C INCH IN DIAMETER SHALL BE PAINTED WITH APPROVED TREE SEALANT. All TREES 2•· BOX AND LARGER SHALL BE SPOTTED AND PLANTED WITH A CRANE. All TREES 2•" BOX AND LARGER SHALL BE SPOTTED IN PLACE PRIOR TO THE DIGGING Of THE HOLE. PLANTING GROUNDCOVERS· A. 8. C. D. GROUNOCOI/ERS SHALL BE PLANTED IN THE .AREAS INDICATED ON THE DRAWINGS THE GROUNDCOVER PLANTS SHALL BE ROOTED CUTTINGS GROWN IN FLATS. AND SH.LL REMAIN IN THOSE FLAlS UNTIL TR•NSPLANTING •LL GROUNDCOVER PLANTS SH•LL IIE PLANTED WITH SOIL AROUND ROOTS IN STAGGERED ROWS, EVENLY SPJoCED AT TliE INTERV,I.LS CALLED Ol/T ON THE DRAWINGS. THE GROUNDCOVER PLANTS SH•LL IIE PL•NTEO SUFflCIENTL Y DEEP TO COVER loll ROOTS ANO A PLANTING TABLET SHALL BE PLACED IN E.lCH PL.lNTING HOLE AND SHALL BE IMMEDIATELY SPRINKLED AFTER PL .. NTING UNTIL THE ENTIRE ARE• IS SOAKED TO THE FULL DEPTH OF ALL THE HOLE$. THE GROUNDCDVER PL .. NTING AREA SHALL 8E HAND- SMO'JTHED AFTER PLANTING TO PROVIDE .AN EVEN. SMOOTH FINAL FINISH GRADE. GROUNDCOVER SHALL BE PLANTED WITHIN 12" OF MAIN PLANT STEM WHERE SHRUBS AND TREES ARE PLANTED. HYDRO-SEEPING SHRUBS TREES AND GRDIJNDCOVERS· A. HYDRO-SEED SHALi.. •E APPLIED IN THE AREAS INDICATED ON THE DRAWINGS AND AS CALLED FOR PfR MIX. ll. HYDRO-SEEDING EQUIPMENT: HYDRAULIC EOUIPMENT USED FOR THE APPLICATION OF FERTILIZER. SEED, AND SLURRY OF PREPARED WOOD Pl/LP OR FIBER SHALL BE OF THE "SUPER 3.6 C. 0. HYDROSEEDER" TYPE AS APPROVED BY THE ARCHITECT THIS EQUIPMENT SHALL HAVE A BUILT-IN AGITATION SYSTEM WITH AN OPERATING CAPACITY SUFFICIENT TO AGITATE SUSPEND, ANO HOMOGENEOUSLY MIX A SLURRY CONTAINING 1,200 POUNDS OF MULCH ANO SEED. THE SLURRY DISTFilBUTION LINES SHALL BE LARGE ENOUGH TO PREVENT STOPPAGE AND SHALL PROVIDE EVEN DISTRIBUTION OF THE SLURRY. THE SLURRY TANK SHALL HAVE A MINIMUM CAPACITY OF 1,350 GALLONS AND SHALL BE MOUNTED ON A TRAVELING UNIT WHICH WILL PLACE THE SLURRY TANK AND SPRAY NOZZLES WITHIN SUFFICIENT PROXIMITY TO THE AREAS TO BE SPRAYED SO AS TO PROVIDE UNIFORM DISTRIBUTION WITHOUT WASTE. APPLICATION METHOD: USING THE WOOD PULP AS A GUIDE THE EQUIPMENT OPERATOR SHALL SPRAY THE SOIL WITH A IJNIFORM VISIBLE CO•T OF SLURRY. THE SLURRY SHALL BE APPLIED IN A SWEEPING MOTION IN AN ARCHED STREAM 60 AS TO FALL LIKE RAIN ALLOWING• THE WOOD FIBERS TO BUILD UPON EACH OTHER, UNTIL A COMPLETE EVEN COVERAGE COAT IS ACHIEVED. ' HYDRO-SEEDED ARE.O.S SHALL IIE KEPT MOIST AT ALL TIMES 20 · 2◄ DAYS AnER PLANTfPjG OR UNTIL THE NEW GROWTH OF THE PLANTS IS Sl/FFICIENTL Y WELL-ESTABLISHED AS PER ARCHlTECT"S APPROVAL. HYDRO-SEEDED ARE.O.S $HALL BE PROTECTED AGAINST F001 TRAFFIC ANO OTHER USE IMMEDIATELY AFTER HYDRO- SEEDING IS COMPLETED 8¥ PLACING W•RNING SIGNS AND TEMPOR-'RY TWINE AND FL•GGING AROUND lHE AREAS. F. RE·HYDRO-SEEDING OF e•AE AREAS SHALL BE DONE THIRTY (30) DAYS AFTER INITIAL APPLICATION. HERBICIDE APPLICATION: PRE-EMERGENT HERBICIDE $HALL BE APPLIED 10 GROl/NDCOVER ARE•S ONLY BY A HERBICIDE APPLIC•TOR LICENSED BY THE STATE OF CALIFORNIA ANO IN ACCORO,.NCE: WITH M•NUFACTURER'$ SPECIFICATIONS ARCHITECT SHALL IIE NOTIFIED .AND PRESENT AT THE TIME OF THE APPLIC.I.TtOt;_ l.7 CLEAN UP: AS PROJECT PROGRES.SES. CONTA.O.CTOR SHALL MAINTAIN ALL AREAS IN A NEAT MANt;ER AND REMOVE UNSIGHTLY DEBRIS AS NECESSARY. jl,.fTER COMPLETION OF PROJECT. CONTRACTOR SHALL REMOVE ALL DEBRIS AND CONTAINERS USED IN ACCOMPLISHING WORK. HE SHALL SWEEP ANO CLEAN All SIDEWALKS, ASPHALT, •NO CONCRETE .I.REAS .O.tlJACENT TO PLANTINGS. . APPROV[D ENGINEERING PLANCHECKER DATE .--~--~----------~·---r----------------" AS BUil T" AP})r{C)VEIJ FC)Fi: PLi1.NTINC; ONLY, "c\N D Tfc RIG-1-\ 17 10 l"J INCL,UDINC; PnDr"'f0T."' f\ r'_; \.,_., _ ~-) r J LOCf\TION OF' FJL),.NTING .4.REi\S. INS'f'ECTOR t---+------+------------..----+---+--~-----1 CTfil I crryLA2!G ~Bkt~AD I~ LANDSCAPE IMPROVEMENTS FOR: PLANNING AREA 27 ~VIARA PHASE II ,...-' . ~. - t----+---t--------+-------+------+--+----"'-----11 APP. · 1 -, • 7_ // ~-/J 7-c;t~c?~ t---+--t---------------------1---1----1-----lf----11 1>-SS;/,;,,l: :-0:" •-~"lNG DlREg~T"-'~~--.L..:.0:-,Ar., TE~,:;..,:__ 1~-DA'I£ N1IAL ·-REVISION DESCRIPTION l b~ l!Y: 11 t-DA_tc_.,_INll'IAL __ -+-_D_A_tc _ __..__M_llAL_-11 CfiKD BY: __ _ D110 NfflOVAL QTY N'f'1tOVAL _ RVWD BY; PRo.ECT NO. CT 90,-3f4--- PLANT LEGEND SYMBOL BOTANICAL NAME TREES EUC. NIC. EUCALYPTUS NICOLII PIN. ELD PINUS ELDARICA SHRUBS HET. ARB. HETEROMELES ARBUTIFOLIA LEP. SCO. LEPTOSPERMUM SCOPARIUM RHU. INT. RHUS INTEGRIFOLIA GROUND COVER COMMON NAME NICHOLL'S WILLOW LEAFED PEPPERMINT MONDELL PINE TOYON BERRY NEW ZEALAND TEA TREE LEMONADE BERRY SIZE 15 GAL. 15 GAL. 24" BOX 5GAL. SGAL. 5GAL. DELOSPERMA ALBA GAZANIA SPLENDENS 'SUNRISE YELLOW' ARCTOSTAPHYLOS HOOKERII WHITE TRAILING ICE PLANT A/Ji<> FLATS YELLOW CLUMPING GAZANIA Cr07° FLATS MONTEREY MANZANITA 1 GAL. lilJ1TIJ I ill NOTES: 1 . AREAS 3:1 OR FLATTER SHALL HAVE MULCH 3" IN DEPTH. (SHALL BE SIMILAR OR EQUAL TO) FOREST HUMUS, SEQUOIA PLANTING MIX, SHREDDED CEDAR BARK. 41 0)2.!-\ 16.Hcµ,_ 2. JUTE MATTING ON SLOPES,A.SHALL BE REQUIRED WHEN PLANTING OCCURS BETWEEN AUGUST 15 AND APRIL 15. 3. TREES AND SHRUBS ARE TO BE SELECTED FROM THE FOLLOWING NURSERIES. FINAL APPROVAL OF PLANT MATERIALS WILL BE BY LANDSCAPE ARCHITECT (ONA, INC.). Bergen's John Stryker (714) 528-0761 Cunnlnghams Larry Cunningham (714) 646-7191 HIilcrest Russ Kelly (1-800) 245-1276 Pardee Trees Ben Dunca (619) 756-3691 Nakase Bros. Sunnyslope Joann Shurlock Beth Stewart (714) 855-4388 (714) 532-1440 Sea Tree Pacifi,:: Coast Nursery Jim Musselman Jim Borer (714) 586-8028 (714) 544-3001 Springtime Valley Crest John Hatch Laurie Borer (619) 455-6810 (818) 367-5803 Norman's Yasuda Nancy Anderson Chip Llever (619) 943-1442 (619) 262-0555 Fourth Avenue Co,porat@ Cen!(tr 15-51 Fourth A\renuB/Sulte 200 San Diego, CA 82101 (519) 239-2450/FAX 2'39-0107 Lilndscape Archit6tdufe • i>1anning COMMENTS MIN. HT. ff. MIN SP 3' MIN. HT. 6', MIN Sf-' 3' MIN HT 10', MIN SP 5' FULL, BUSHY, GOOD COLOR FULL, BUSHY, GOOD COLOR FULL, BUSHY. GOOD COLOR PLANT@ 12" O.C. PLANT@ 12" O.C. PLANT @ 12' O.C. ::;EE 71--/6 .5/IY-;(J2_ 7"'J"Pe-OP ,"1/X. DET. NO. B B B A A A C C C HYDROSEED MIX / COVER CROP BOTANICAL SEED NAME RATE: LBS/ACRE Alyssum 'Carpet of Snow' ,.., 4 LBS. Alyssum 'Royal Carpet' 4 LBS. The following materials shall be in the mix: Mulch -Conweb Fiber 2,200 lbs./acre Binder -Terra Tac #3 150 lbs./acre Fertilizer 16-20-0 400 lbs./acre A C • TREE TIE 1BEE-~ - -~~~ ~ ~ Fl=R-F¾l □f'. sP~s. ~ 'c=J ~ $ t:DTTD-1 ~IU....1'1IX \) --$1=1, 11~ I + SHRUB PLANTING ON SLOPE B TREE PLANTING & STAKING N.T.S. N.T,S. ON SLOPE PLANTING DISTANCE SCHEDULE FEET ON CENTER ROW DISTANQE SET BA~K '..A:. '...B.' :c..: 8" 7" 7" 1'-0" 10.5" 11" 1 '--6'' 1'-4" 1--0" 2· -0" 1'-9" 1 '-6'' 3'-0" 2'-6" 2' -6" 6'-0" 5• ... 2" 5'•6" 10'-0" 8' ... 8" 9'-6" PLANTING GRID • • • • • • -~ [D' • • • • • • • • • • • • • • • • • • • • • -~ • • • • • • • • • • • • • • • • • • • • • ·ot GROUNDCOVER PLANTING "AS BUil T" A.PPFcO\i"::SD FC)R PL!0,.NTING.: N.T.S. AJ\JD IRRIC;·A'I'ION. ONL '{, .. ------ Ii'\JCL-UDINC; PRT~CTSl~ RC£ --EXP. ---DATE APPROVED r (I C 6 ,·1, ·1 () Nf O F·' p 'L' 2 :-T 1' ·1·· 'Tr• REVIEWED BY: •. 1 , .-rl. . _ l . c·I.: 'l ~ "i \...T ENGINEERING PLANCHECKER DATE INSPECTOR DATE I ~IF7 I CITY OF CARLSBAD I SHIE~.l lS I i----;------,i----------------+----+------1---+-------I "9-PLAl'I.NJNG . DEP ARTI.!ENT -'J-~--;------,i---------------+----+------1---+------I LANDSCAPE IMPROVEMENTS FOR: PLANNING AREA 27 RA HASE 11 ...JlAlI ¥1111 DIGINEER OF WORK REVISION DESCRIPTION o.-.n: INll\AL -0.-.rr INll\,l,I_ O'llll.R APPROY,lj_ aTY APPROVAL