HomeMy WebLinkAboutPRE 2021-0023; 2200 FARADAY SITE AMENITY ADDITIONS; Admin Decision LetterJune 23, 2021
Norman Barrett
Smith Consulting Architects
13280 Evening Creek Drive, Suite 125
San Diego, CA 92128
Ccityof
Carlsbad
8FILE COPY
/J'ltt.,1~.J 6/23/21
SUBJECT: PRE 2021-0023 (DEV2021-0099)-2200 FARADAY SITE AMENITY ADDITIONS
APN: 212-120-60-00
Thank you for submitting a preliminary review to add two outdoor employee seating areas totaling 3,551
square feet located at 2200 Faraday Avenue. The project site, which comprises of a 13.86-acre site, is
currently developed with an industri;,I building onsite.
In response to your application, the Planning Division has prepared this comment letter. Please note that
the purpose of a preliminary review is to provide you with direction and comments on the overall concept
of your project. This preliminary review does not represent an in-depth analysis of your project. It is
intended to give you feedback on critical issues based upon the information provided in your submittal.
This review is based upon the plans, policies. and standards in effect as of the date of this review. Please
be aware that at the time of a formal application submittal, new plans. policies, and standards may be
in effect and additional issues of concern may be raised through a more specific and detailed review.
Planning:
General
1. General Plan and zoning designations for the property are as follows:
a. General Plan: Planned Industrial (Pl)
b. Zoning: Heavy Commercial -Limited Industrial Zone {C -M)
c. The property is located within Area 1 of the Carlsbad Research Center Specific Plan.
2. The project requires the issuance of a building permit. Please contact the Building Division for
submittal requirements at building@carlsbadca.gov.
3. Development Standards. Staff supports the proposed two outdoor employee areas subject to
compliance with the requirements of the Carlsbad Research Center Specific Plan. The comments
provided below are not inclusive of all the requirements. Please refer to the Carlsbad Research Center
Specific Plan for all requirements.
Community Development
Planning Division I 1635 Faraday Avenue Carlsbad, CA 92008-7314 I 760-602-4600 I 760-602-8560 f I www.carlsbadca.gov
. PRE 2021-0023 (DEV2021-0099)-2200 FARADAY SITE AMENITY ADDITIONS
June 23, 2021
Pa e 2
a, Site Coverage. The maximum building coverage of all buildings, including accessory
structures, shall not exceed 50 percent of the gross lot area. The plans submitted for a
building permit must provide a lot coverage breakdown and include any proposed trellis
or shade structures.
·b: · Setbacks. No structure shall be located within 30 feet of the front property line. Plans
submitted for a building permit are required to provide a full site plan with all setback
dimensions and must comply with the standards contained within the Carlsbad Research
Specific Plan.
c. Walls and Fences.
i. No wall or fence exceeding 42 inches in height shall be constructed closer than
30 feet from the front property line abutting Faraday Avenue. In addition, no
fence, wall, or retaining wall shall exceed a height of eight feet outside of the 30-
foot front yard setback from the front property line.
ii. Fences and walls must be designed as an integrated part of the building
architecture and site design. Plans submitted for a building permit must provide
full wall/fence details including height and length dimensions, color, and
materials that complement the overall architecture and design of the existing
building.
d. Landscaping.
i. A minimum of 15 percent of the gross lot area must be landscaped. Plans
submitted for building plan check are required to show the total square footage
of landscaping onsite and must maintain the 15 percent landscape requirement,
after the removal of the existing landscaping to accommodate the proposed
outdoor employee areas.
ii. If the project is required to replace 2,500 square feet or more of the existing
landscaping to meet the minimum 15 percent landscaped area, conceptual
landscape exhibits shall be prepared in accordance with the General
Requirements listed in Section 3 of the City of Carlsbad Landscape Manual, and a
landscape plan check is required. A landscape plan check is a separate but
concurrent process with the building plan check review. However, a building
permit will not be issued until the landscape plan check is approved. The
landscape plan check must be submitted through the Planning Division by
emailing devappt@carlsbadca.gov to schedule an appointment. Questions
regarding the submittal requirements for a landscape plan check can be directed
to olanning@carlsbadca.gov. The landscape manual may be obtained online at:
httos://www.carlsbadca.gov/home/showdocument?id-234
All necessary application forms, submittal requirements, and fee information are available at the Planning
counter located in the Faraday Building at 1635 Faraday Avenue or online at
https://www.carlsbadca.gov/departments/community-develooment/olanning. You may also access the
General Plan Land Use Element and the Zoning Ordinance online at the website address shown; select
Department Listing; select Planning Home Page. Please review all information carefully before submitting.
·•--··-··---------------
PRE 2021-0023 {DEV2021-0099)-2200 FARADAY SITE AMENITY ADDITIONS
June 23, 2021
Pa e 3
Land Development Engineering:
1. Complete the city's Storm Water Standards Questionnaire (Form E-34}. This questionnaire will guide
you and the City in determining what type of reports and storm water mitigation must be completed
to satisfy state and City storm water quality requirements. The questionnaire can be obtained on the
city's web site. Preliminary analysis suggests that the project is a 'Standard' Project and shall provide
two completed Standard Project Requirement Checklist (E-36 Form). The form is available on the city's
website.
2. Show and label the existing easements on the site plan.
3. Provide on the site plan the legal description of the property and assessor's parcel number {APN).
4. Provide on the site plan the earthwork quantities of cut, fill, import, export, and remedial grading in
cubic yards.
5. Provide on the site plan for the proposed retaining walls, the top of wall, finish surface, and top of
footing elevations.
6. Verify that the proposed work can properly convey drainage through the area and does not impact
existing drainage paths.
Building:
1. The proposed project will require accessible benches installed per 2019 CBC 1.16-903.
If you would like to schedule a meeting to discuss this letter with the commenting departments, please
contact Jessica Evans at the number below. You may also contact each department individually as follows:
• Planning Division: Jessica Evans, Associate Planner, at {760) 602-4631
• Land Development Engineering: Kyrenne Chua, Associate Engineer, at {760) 602-2744
• Building Division: Jason Pasiut, Building and Code Enforcement Manager, at (760) 602-2788
Sincerely,
DON NEU, AICP
City Planner
DN:JE:cf
c: Kyrenne Chua, Project Engineer
HPRM/File Copy
Data Entry