HomeMy WebLinkAboutCUP 2017-0009; Eco-Friendly Auto Spa; Modified Curb - Cantilevered Retaining Wall, Avenida Encinas Car Wash Eco-Friendly Auto Spa; 2020-03-03ECO-Friendly Auto Spa
CUP 2017-00009/GR2019·0011/DWG 517-2A
10-13214T
Modified Curb
TIUe
Job#:
Description ....
Dsgnr:
This Wall in File: \\Esc server\projects\10-13000 to 10-13999 Projects\10-13214C\RetainPro\5-Modifi
Page : 2
Date: 3 MAR 2020
RetalnPro (c) 1987-2017, Build 11.17.06.23
License : KW-06054060 License To: CTE
Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
Concrete Stem Rebar Area Details
Bottom Stem
As (based on applied moment) :
(4/3) *As :
200bd/fy : 200(12)(4.1875)/60000 :
0.0018bh : 0.0018(12)(6):
Vertical Reinforcing
0in2/ft
O in2/ft
0.1675 in2/ft
Horizontal Reinforcing
Min Stem T&S Relnf Area 0.000 in2
Min Stem T&S Reinf Area per ft of stem Height : 0.000 in2/ft
0.1296 in2/ft Horizontal Reinforcing Options :
------------One layer of : Two layers of :
Required Area : 0.1296 in2/ft #4@ 0.00 in #4@ r,0:-;:0-:-in ____ R_E ___________ _
ProvidedArea : 0.2325in2/ft #5@ 0.OOin #5@ .00in CORD COPY
Maximum Area : 0.5673 in2/ft #6@ 0.00 In #6@ I Footing Dimensions & Strengths • Footing Design Results I _ '9t /Ll t:~) /, If, 2-P
Toe Width = 0.33 ft la. In itia f Date
~~:l~~~tng Width : t~j ~~~~~:a~ssure : 1 •0;~ 1.~~419--pftel-#f---------_____ _,
Footing Thickness = 18.00 in Mu': Downward = 15 2,119 ft-# Mu: Design = 43 305 ft-#
Key Width = 8-00 in Actual 1-Way Shear 1.24 1.24 psi
Key Depth = 14.oo In Allow 1-Way Shear = 40.00 40.00 psi
Key Distance from Toe = 0.33 ft Toe Reinforcing = # 5@ 18.00 In
re = 2,500 psi Fy = 60,000 psi Heel Reinforcing = # 5@ 18.00 in
Footing Concrete Density = 150.00pcf Key Reinforcing = None Spec'd
Min. As% = 0.0018 Other Acceptable Sizes & Spacings Cover@ Top 2.00 @ Btm.= 3.00 In Toe: Not req'd: Mu < phl*5*1ambda*sqrt(fc)*Sm
Heel: Not req'd: Mu < phi*5*1ambda*sqrt(fc)*Sm
Key: Not req'd : Mu< phi*5*1ambda*sqrt(fc)*Sm
Min footing T&S relnf Area 1.23 in2
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
0.39 in2 1ft
#4@ 6.17 In
#5@ 9.57 in
#6@13.58 in
If two layers of horizontal bars:
#4@ 12.35 In
#5@ 19.14 in
#6@27.16 in
I Summary of Overturning & Resisting Forces & Moments
..... OVERTURNING ..... Force Distance Moment
Item
Heel Active Pressure
Surcharge over Heel
Surcharge Over Toe
=
Adjacent Footing Load =
Added Lateral Load
Load @ Stem Above Soil =
=
Total
=
Resisting/Overturning Retio
lbs ft ft-#
375.0 1.67 625.0
2.50
375.0 O.T.M. 625.0
Vertical Loads used for Soll Pressure =
= 5.08
1,812.7 lbs
Soil Over Heel =
Sloped Soil Over Heel =
Surcharge Over Heel =
Adjacent Footing Load =
Axial Dead Load on Stem =
• Axial Live Load on Stem
Soil Over Toe
Surcharge Over Toe
Stem Weight(s)
=
Earth @ Stem Transitions=
Footing Weight =
Key Weight =
..... RESISTING ..... Force Distance
lbs ft
982.8 2.00
713.3 1.59
116.7 0.66
Vert. Component _= ____ _
Moment
ft-#
1,965.6
1,130.5
77.4
Total• 1,812.7 lbs R.M.• 3,173.5
Vertical component of active lateral soil pressure IS NOT considered In
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overtuming Resistance.
• Axial live load NOT Included in total displayed, or used for overturning
resistance, but is included for soil pressure calculation.
E E
MAR 2 0 2020
LAND D VELOPMENT
EN,.....IN _ERIN G
-.....
C:
:tr...
(!_) ~-~
CD
(1)
C\j .c.
(.)
~
•
t::) ,..,
~
c-' -r-
'---s-
ECO-Friendly Auto Spa Page : 1
CUP 2017-00009/GR2019-0011/DWG 517-2A
10-132141
Title
Job#: Dsgnr: Date: 3 MAR 2020
Description ....
Modified Curb
This Wall In File: \\Esc server\projects\10-13000 to 10-13999 Projects\10-13214C\RetainPro\5-Modifi
~::~':~
0~1:=· euud 11
·
11
·
0623 Cantilevered Retaining Wall
License To: CTE Code: CBC 2016,ACI 318-14,ACI 530-13
.,I c.r.it.er.ia _________ l I Soil Data I
Retained Height 3.50 ft
Wall height above soil = 0.50 ft
Slope Behind Wall = 0.00
Height of Soil over Toe = 0.OOin
Water height over heel = 0.0 ft
I Surcharge Loads • Surcharge Over Heel = 0.0 psf
Used To Resist Sliding & Overtuming
Surcharge Over Toe 0.0
Used for Sliding & Overtumlng
! Axial Load Applied to Stem I
Axial Dead Load =
Axial Live Load =
Axial Load Eccentricity =
I Design Summary
Wall Stabllity Ratios
0.0ibs
0.0ibs
0.0in
• Overtumlng =
Sliding =
5.08 OK
3.49 OK
Total Bearing Load
... resultant ecc.
1,813 lbs
2.15 in
Soil Pressure @ Toe = 766 psf OK
Soil Pressure @ Heel = 378 psf OK
Allowable = 2,500 psf
Soil Pressure Less Than Allowable
ACI Factored @ Toe = 1,072 psf
ACI Factored @ Heel = 529 psf
Footing Shear@ Toe = 1.2 psi OK
Footing Shear @ Heel = 0.5 psi OK
Allowable 75.0 psi
Sliding Cales
Lateral Sliding Force =
less 100% Passive Force = •
less 100% Friction Force =
Added Force Req'd =
... .for 1.5 Stability =
375.0 lbs
763.9 lbs
543.8 lbs
0.0 lbs OK
0.0 lbs OK
Allow Soil Bearing = 2,500.0 psf
Equivalent Fluid Pressure Method
Active Heel Pressure = 30.0 psf/ft
=
Passive Pressure = 250.0 psf/ft
Soil Density, Heel = 120.00 pcf
Soil Density, Toe = 0.00 pcf
Footingl!Soil Friction = 0.300
Soil height to ignore
for passive pressure = 12.00 in
1· ~ ~
I_._J
I Lateral Load Applied to Stem • I Adjacent Footing Load
Lateral Load = 20000.0 #/ft
... Height to Top = 1.00 ft
... Height to Bottom = 1.00 ft
Load Type = Live Load (L)
(Service Level)
Wind on Exposed Stem =
(Service Level)
I Stem Construction
Design Height Above Ftg
Wall Material Above "Ht"
Design Method
Thickness
Rebar Size
Rebar Spacing
Rebar Placed at
0.0 psf
• 2nd
Stem OK
ft= 4.00
= Concrete
= LRFD
= 6.00
= # 5
= 16.00
= Edge
Adjacent Footing Load
Footing Width
Eccentricity
Wall to Ftg CL Dist
Footing Type
Base Above/Below Soil
at Back of Wall
Poisson's Ratio
Design Data
fb/FB + fa/Fa = 0.000
Total Force @ Section
Service Level
Strength Level
Moment. ... Actual
Service Level
Strength Level
Moment. .... Allowable
Shear ..... Actual
Service Level
Strength Level
Shear ..... Allowable
Anet (Masonry)
Rebar Depth 'd'
lbs=
lbs=
ft-#=
ft-#=
=
psi=
psi =
4,094.1
psi= 75.0
in2=
in= 4.19
=
=
=
=
=
=
0.0lbs
0.00 ft
0.00 in
0.00 ft
Line Load
0.0 ft
0.300
Masonry Data -------------------------
Vertical component of active lateral soil pressure IS
NOT considered in the calculation of soil bearing
Load Factors ------------
Building Code
Dead Load
Live Load
Earth,H
Wind,W
Seismic, E
CBC 2016,ACI
1.200
1.600
1.600
1.000
1.000
fm
Fs
Solid Grouting
Modular Ratio 'n'
Wall Weight
Short Term Factor
Equiv. Solid Thick.
Masonry Block Type
Masonry Design Method
psi =
psi=
=
psf= 75.0
= Medium Weight
= ASD
Concrete Data ------------------------
fc
Fy
psi = 2,500.0
psi= 60,000.0
ECO-Friendly Auto Spa
CUP 2017-00009/GR2019-0011/DWG 517-2A
10-132141
Modified Curb
Title
Job#:
Description ....
Dsgnr:
This Wall in File: \\Esc server\projects\10-13000 to 10-13999 Projects\10-13214C\RetainPro\5-Modifi
RetalnPro (c) 1987-2017, Bulld 11.17.06.23
License : KW-06054060
License To : CTE
I TIit I
Cantilevered Retaining Wall
Horizontal Deflection at Jop of Wall due to settlement of son
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus
Horizontal Dell @ Top of Wall (approximate only)
250.0 pci
0.027 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil
Page : 3
Date: 3 MAR 2020
Code: CBC 2016,ACI 318-14,ACI 530-13