Loading...
HomeMy WebLinkAboutDWG 530-5L; PUD 2020-0001; HEMLOCK COAST HOMES; 01-12DRAWING INDEX· • SHEET TITLE TITLE SHEET CONSTRUCTION PLAN CONSTRUCTION DETAILS IRRIGATION PLAN IRRIGATION DETAILS IRRIGATION DETAILS IRRIGATION DETAILS & NOTES PLANTING PLAN PLANTING LEGEND PLANTING DETAILS PLANTING NOTES WATER CONSERVATION PLAN LANDSCAPE IMPROVEMENT PLANS FOR SHEET NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 HEMLOCK COAST HOMES 320 HEMLOCK AVE. CARLSBAD, CALIFORNIA VICINITY MAP CITY OF OCEANSIDE PACIFIC OCEAN LOCATION MAP 78 CITY OF VISTA ~i,_..._.:.::RO~M!!..-,--------t- '1-o-f>, CITY OF _;,,.---. '-I SAN MARCOS AVE CITY OF ENCINITAS NOTTO SCALE ""''1!ll -=ah ~ = = = 2725Jefforaon street, &Lllto 15b cmrl11bE1d, oa 92008 phcne: 760,720.9337 fa:it: 760.720.9505 • it z. 5d i ~ '-I ' * V R ""'-Da~ * -~-"I~ J <!>,"-. oa,, ~ ;,, ~ ~ 'I~ OF CP.Llf~ Exoiralion Dale: DATE INITIAL M30123 DESIGNER OF WORK /1\ DECLARATION OF RESPONSIBLE CHARGE: I HEREBY DECLARE THAT I AM THE LICENSED DESIGNER DF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THIS PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONSBYTHE CITY OF CARLSBAD AND SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH IS CONFINED TO A REVIEW ONLY AND DOES NOT RELIEVE ME, AS THE LICENSED DESIGNER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. THESE PLANS HAVE BEEN PREPARED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED LANDSCAPE CONCEPT PLAN, WATER CONSERVATION PLAN, FIRE PROTECTION PLAN, AND ALL CONDITION OVAL RE ED TO LANDSCAPING. : 1760) 72D-9337 REGISTRATION NO: 2994 DATE: 718121 EXPIRATION DATE: 4/30123 WATER EFFICIENT LANDSCAPE DECLARATION: I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL & WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER. B : 1760) 720-9337 REGISTRATION NO: 2994 DATE: 718121 EXPIRATION DATE: 4130123 BACKFLOW PREVENTER TESTING: ALL BACKFLOW PREVENTERS SHALL BE TESTED BY A CERTIFIED TESTER AND RESULTS MUST BE GIVEN TO THE CITY AND THE WATER DISTRICT. CALL (760) 438-2722 TO OBTAIN APPROVED CONTRACT BACKFLOW TESTERS, PIPE BETWEEN THE METER AND BACKFLOW PREVENTER SHALL BE "SCHEDULE K HARD COPPER". DESIGN REVIEW LIMITATIONS: A SEPARATE CITY REVIEW AND APPROVAL IS REQUIRED FOR ANY PORTION OF THESE PLANS REQUIRING A BUILDING PERMIT. CITY APPROVAL OF THESE PLANS IS FOR LANDSCAPE PLANTING AND IRRIGATION ONLY. INSPECTION PROCEDURES: . INSPECTION PROCEDURES: INSPECTION OF THE PROJECT SHALL BE PERFORMED BY THE LANDSCAPE ARCHITECT OF WORK, OR HIS DESIGNATED AGENT. REFER TO THE SPECIFICATIONS FOR THE SCHEDULE OF REQUIRED INSPECTIONS AND REQUIRED SUBMITTALS. FOLLOWING COMPLETION OF THE WORK, THE LANDSCAPE ARCHITECT OF THE WORK WILL CERTIFY THAT THE INSTALLATION HAS BEEN COMPLETED BY SUBMITTING THE "CERTIFICATION OF COMPLETION" FORM. A REQUEST FOR A FINAL LANDSCAPE INSPECTION BY THE CITY MUST ALSO BE MADE BY CALLING THE INSPECTION REQUEST LINE. "FINAL LANDSCAPE CERTIFICATION FORM" E-MAILW· BP@PUGMQREDESIGNSTUDIO,COM LANDSCAPE INSPECTION REQUEST PHONE LINE 1760) 436-7327 PRIOR TO BEGINNING LANDSCAPE WORK: THE CONTRACTOR SHALL CONTACT THE DESIGNER OF WORK PRIOR TO BEGINNING LANDSCAPE WORK AND THE DESIGNER OF WORK SHALL REVIEW THE PROJECT UTILITY LOCATIONS AND REVISE PLANS ACCORDINGLY TO FULLY SCREEN ALL UTILITIES FROM VIEW AND PROTECT ALL UTILITIES (ABOVE & BELOW GRADE) FROM INVASIVE PLANT GROWTH AND ROOTS, APPROVED FOR /RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE LOCA T/ON OF PLANTING AREA. "AS BUILT" . J\PPROVED DATE RCE EXP. «'""f})N ~TRlJCl~iOi¾j t\.:'."~~l -\~» : , -.,,.w ; -i · . ~-SET REVIEWED BY: INSPECTOR DATE ~ I SH~ET I CITY OF CARLSBAD PLANNING DIVISION 2 LANDSCAPE IMPROVEMENT PLANS FOR: HEMLOCK COAST HOMES 320 HEMLOCK AVENUE, CARLSBAD, CA TITLE SHEET !APPROVE~~ I j/1-+/2-1 PLANNING DWN BY: JSS PROJECT NO. DRAWING NO. DATE INITIAL DATE INITIAL CHKD BY: JSS REVISION DESCRIPTION RVWDBY: LPC2021-0012, PUD2020-0001 530-5L OTHER APPROVAL CITY APPROVAL PLOT DATE: 7/8/21 2021-03-30_Hemlock Homes lille Block.vwx X _...,.,.. _____ '· ,! ,, 111 Ii ,1 ,, ' : I I I ' I ' 'I I . I I I I I \ : I PA PA PA \i' \ I PA PA ' ' ·OATS PA -f G -+---G s G _ I I ~r/ RT DIAL TOLL FREE 1 -800 -422 -4133 AT LEAST TWO DAYS BEFORE YOU DIG ' < C 4 ". G---G---G HEMLOCK UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA a':l 6'-0" fe .. 6'-0" 3'-4" 0 -_, N ,!< 0 ~ 9 -:.,. = z PA -. _o_ (jJ ss s __ & __ ~ I JJ97G ;G ell fl j l~E, /j/ 7· rn ==f= Ml / ,,,,I a: ~ THIS SECTION OF FENCING IS TO MATCH THE 1---EXISTING FENCING LOCATED ALONG THE WESTERN PROPERTY LINE GENERAL NOTES 1. CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF ANY ERRORS, OMISSIONS OR DISCREPANCIES IN EXISTING CONDITIONS OR WITHIN THE PLANS PRIOR TO BEGINNING THE WORK. IMMEDIATE NOTIFICATION WILL BE GIVEN TO THE LANDSCAPE ARCHITECT SHOULD SUCH A CONDITION BE DISCOVERED. 2. CONTRACTOR SHALL VERIFY LOCATION OF AND PROTECT ALL EXISTING UNDERGROUND UTILITIES BEFORE EXCAVATION. (UNDERGROUND SERVICE ALERT 1-800-422-4133). THIS APPLIES TO GENERAL CONTRACTOR AND ALL SUBCONTRACTORS. 3. 4. 5. 6. 7. 8. COORDINATING ALL WORK WITH ALL TRADES SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THIS INCLUDES, BUT IS NOT LIMITED TO, LAYOUT, SLEEVING, AND CHASE LINES, STEEL REINFORCEMENT, ANCHORING, AND ALL SCHEDULING. ANY AND ALL SUBCONTRACTORS WILL FAMILIARIZE THEMSELVES WITH ALL ASPECTS OF THE CONTRACT DOCUMENTS THAT PERTAIN TO THEM. ALL WORK SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE CITY OF CARLSBAD. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY AND/OR REQUIRED PERMITS AND PAY ALL RELATED FEES AND/OR TAXES REQUIRED TO INSTALL THE WORK ON THESE PLANS. DETERMINATION OF "EQUAL" SUBSTITUTIONS SHALL BE MADE ONLY BY THE LANDSCAPE ARCHITECT. ALL EXISTING CONDITIONS ON THE SITE SHALL BE PROTECTED, ESPECIALLY UTILITIES. CONTRACTOR SHALL RETURN ALL PORTIONS OF THE SIT.E TO THEIR ORIGINAL CONDITIONS, OR BETTER, WHEREVER THEY HAVE BEEN DISTURBED BY CONSTRUCTION. 9. ALL WALL FOOTINGS SHALL BE PLACED ON 95% COMPACTED IMPORT FILL OR 12' MINIMUM INTO NATIVE GRADE. SEE GEOTECHNICAL REPORT DATED 24 AUGUST 2020 FOR ADDITIONAL INFORMATION. 10. ALL SUBGRADES UNDER FLATWORK SHALL BE COMPACTED TO MINIMUM 95%, SEE GEOTECHNICAL REPORT DATED 24 AUGUST 2020 FOR ADDITIONAL INFORMATION. 11. CONCRETE SHALL BE "LARGE ROCK:' PUMP MIX 3,500 PSI MINIMUM AT 28 DAYS, SLUMP SHALL NOT EXCEED 4" UNLESS OTHERWISE NOTED. 12. CONCRETE SHALL HAVE 118" PER FOOT PITCH MIN., SEE CIVIL PLANS FOR VERTICAL CONTROL INFORMATION. 13. CONCRETE CONTRACTOR SHALL TAKE CARE NOT TO FLOAT EXCESS CEMENT OR WATER INTO ANY DRAINS. WASTE CEMENT, CONCRETE, AND WASTE WATER SHALL BE PROCESSED PER STATE AND LOCAL CODES. 14. EXPANSION JOINT SIZE SHALL BE 1/2'' WIDE AND THROUGH THE ENTIRE PAVEMENT TO SUBGRADE UNLESS OTHERWISE NOTED. 15. ALL WALLS SHALL BE INSTALLED PRIOR TO FLATWORK INSTALLATION. 16. ALL NAILS (BOXED NAILS), SCREWS, BOLTS, NUTS, FASTENERS, CLIPS, AND WASHERS ARE TO BE STAINLESS STEEL. 17. ALL BOLT AND SCREW HOLES SHALL BE PREDRIULED. 18. TOP OF ALL WALLS SHALL REMAIN CONSTANT U.0.N. ON THE PLANS, SEE CIVIL DRAWINGS FOR VERTICAL CONTROL INFORMATION. 19. NO CURING COMPOUNDS SHALL BE USED FOR ANY CONCRETE SUBSTRATES UNDER BRICK, TILE OR STONE VENEER MATERIALS. 20. ALL CONTRACTORS SHALL BE APPROPRIATELY LICENSED AS REQUIRED BY STATE LAW TO PRACTICE THEIR PARTICULAR TRADE. 21. LANDSCAPE ARCHITECT SHALL BE NOTIFIED NO LESS THAN 48 HOURS IN ADVANCE OF ANY SITE OBSERVATIONS OR MEETINGS. 22. FOR VERTICAL CONTROL INFORMATION, SEE CIVIL DRAWINGS. FOR ADDITIONAL HORIZONTAL CONTROL INFORMATION, SEE ARCHITECT'S SITE PLAN AND CIVIL DRAWINGS. CONTRACTOR'S CONSTRUCTION WORK RESPONSIBILITIES CONSTRUCTION LEGEND 1. 2. 3. 4. 5. SCOPE OF WORK: THE CONTRACTOR SHALL PROVIDE ALL LABOR MATERIALS, TRANSPORTATION AND SERVICES NECESSARY TO FURNISH AND INSTALL ALL CONSTRUCTION ELEMENTS AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. CONFORMANCE: ALL CONSTRUCTION WORK SHALL CONFORM TO APPLICABLE LOCAL, COUNTY AND/OR STATE CODES, REGULATIONS AND RULES. LICENSE: ALL WORK SHALL BE PERFORMED BY A CALIFORNIA LICENSED CONTRACTOR. PERMITS AND INSPECTIONS: THE CONTRACTOR SHALL OBTAIN, COORDINATE, AND PAY FOR ANY AND ALL PERMITS, FEES AND AGENCY INSPECTIONS AS REQUIRED. INSURANCE: THE CONTRACTOR SHALL CARRY ALL WORKMAN'S COMPENSATION, PUBLIC LIABILITY, AND PROPERTY DAMAGE INSURANCE AS REQUIRED BY ALL APPLICABLE CODES, REGULATIONS. 6. SITE VERIFICATION: PRIOR TO COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VERIFY, AT THE SITE, ALL CONDITIONS AND DIMENSIONS SHOWN ON THE PLANS AFFECTING THE INTENDED DESIGN OF THE CONSTRUCTION WORK. ANY DISCREPANCIES SHALL BE REPORTED TO THE PROJECT'S JOB SUPERINTENDENT IMMEDIATELY. 7. LIABLE FOR ENCROACHMENT: THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION ENCROACHMENT INTO ADJACENT PROPERTY, RIGHT-OF-WAYS, EASEMENTS, SET-BACKS OR ANY OTHER LEGAL PROPERTY RESTRICTIONS EITHER MARKED OR UNMARKED. 8. COORDINATION OF ACTIVITIES: THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF HIS ACTIVITIES WITH ALL OTHER TRADES THROUGH THE OWNER OR JOB SUPERINTENDENT. 9. FIELD STAKING: PRIOR TO INSTALLATION, THE CONTRACTOR SHALL LOCATE BY STAK:ES OR OTHER MEANS, ALL CONSTRUCTION ELEMENTS AS DELINEATED ON THE PLANS FOR APPROVAL BY THE JOB SUPERINTENDENT AND LANDSCAPE ARCHITECT. 10. NOTIFICATION OF DISCREPANCIES: ANY DISCREPANCIES BETWEEN THE FIELD CONDITIONS AND THE CONTRACT DOCUMENTS AND/OR THE DESIGN INTENT AFFECTING THE SUCCESSFUL COMPLETION AND COST OF THE PROJECT SHALL BE REPORTED TO THE OWNER AND LANDSCAPE ARCHITECT IMMEDIAT.ELY. ALL WORK RELATED TO THE PROBLEM AREA SHALL CEASE UNTIL THE DISCREPANCIES HAVE BEEN RESOLVED BY THE OWNER OR LANDSCAPE ARCHITECT IN WRITING. ANY CONTINUATION OF WORK IS AT THE CONTRACTOR'S RISK AND EXPENSE. 11. LIABLE FOR DAMAGE: THE CONTRACTOR SHALL BE LIABLE FOR DAMAGE TO ALL UTILITIES, CONSTRUCTION, IRRIGATION AND PLANTING ELEMENTS, EXISTING OR NEW, MARKED OR UNMARKED, AND SHALL REPAIR DAMAGE IN A MANNER ACCEPTABLE TO THE OWNER. 12. EXISTING UTILITIES: CONTRACTOR SHALL VERIFY LOCATION OF AND PROTECT ALL EXISTING UNDERGROUND UTILITIES BEFORE EXCAVATION, (UNDERGROUND SERVICE ALERT 1-800-227-2600). THIS APPLIES TO GENERAL CONTRACTOR AND ALL SUBCONTRACTORS. App' •' ~. 1J(('j)\\/f.'[i)) tr'h ·v:;p 1J ~! ~,:,zj NUMBER 0 0 CONs·rRU(C~:1~1Cv~~,ll SfET 10 0 5 10 20 40 ~ I I I I SCALE: 1"=10'-0" FEET SYMBOL o=3'-6''===6'-D"===o DN~ I: , ' •. :I •.·. , - ---· ' ------ EJ-' PA F.0.B. DESCRIPTION HORIZONTAL VINYL FENCING, HEIGHTS TO BE 3'-6" AND 6'-0", SEE PLAN EXSTING 6' HIGH WOODEN FENCE TO REMAIN CONCRETE STEPS PI.P. CONCRETE WITH ENTEGRAL COLOR AND LIGHT ETCHED FINISH. WEAKENED PLANE JOINTS TO BE SAWCUT. PERMEABLE MODULAR PAVERS, MANUFACTURER: ORCO BLOCK AND HARDSCAPE, PAVER MODEL: ATTRAVERSO, PATTERN: HERRINGBONE, COLOR: MANOR, SEE CIVIL DRAWINGS FOR INSTALLATION DETAILING. PRODUCTION CONCRETE WITHIN THE PUBLIC R.OW., SEE CIVIL DRAWINGS WEAKENED PLANE JOINTS EXPANSION JOINT ALUMINUM EDGING ALONG DECOMPOSED GRANITE PAVING 3'-0" WIDE VINYL GATES, MATCH HEIGHT OF THE ADJACENT FENCING. HANDRAIL PLANTED AREA ALIGN WITH FACE OF BUILDING DTL.ISHT. REFERENCE F/3 8/3 A/3 C/3 D/3 G/10 F/3 E/3 APPROVED FOR /RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUILT" RCE EXP. DATE REVIEWED BY: INSPECTOR DATE l---+---1------------------t---t---,--,--i PLANNING DIVISION I SH2EET I CITY OF CARLSBAD r-------------t=====1=====t=================================+=====+=====~=====~====1 LANDSCAPE IMPROVEMENT PLANS FOR: 2725Jofforaol'l atroot, suno 15b carl ■bad, ca 92008 phcna: 760.720.9337 fax: 760.720.9505 Ex lralkm Date: 4/30/23 HEMLOCK COAST HOMES 320 HEMLOCK AVENUE, CARLSBAD, CA CONSTRUCTION PLAN APPROVED: 1----1---1-----------------+---+---f---t---J ~~P:=LA:=_N':::_N::I_N:::G-=-=-=--=;.;;;;;;:-=_::;-;:_=-=-=-=-::::.::::.=-=-=-=-=-=-=-=-=-=-=-,~~=========:= DWN BY: JSS PROJECT NO. DRAWING NO. DATE INITIAL DESIGNER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL CHKDBY: JSS RVWD BY: LPC2021-0012, PUD2020-0001 530-5L PLOT DATE: 718/21 2021-03-30_Hemlock Homes Title Block.vwx Q] FINISH GRADE ~ 0 1/2" RADIUS @] !] #3 NOSE BAR ALONG ENTIRE PERIMETER 0 LITE ACID ETCHED FINISH NOTES: #3 REBAR@ 1 B O.C. BOTH WAYS. 0 NATIVE SOIL SUBGRADE, SET ON CONC. CHAIRS. CONCRETE SLAB q • ' . '• . , ·•: •, , . 3" CLR. 3 .. 6" 4 ~ . SEE GEOTECHNICAL REPORT 0 DEEPENED EDGE 0 CLASS II BASE MATERIAL. COMPACT WITH FLAT PLATE VIBRATOR TO A MIN. OF 90%, DEPTH TO BE 4". 5 ,. .-. ~ . . . · .. '<f • A • • • 4 • • • • . ' . . V' . . . . . . . . .-.o ·-0.' 9 1. INTEGRAL CONCRETE COLOR TO BE SILVERSMOKE #8084 BY DAVIS COLOR. FINAL COLOR SELECTION TO TAKE PLACE TWO (2) WEEKS PRIOR TO FORMING. CONTACT LANDSCAPE ARCHITECT Al THAT TIME. 2. SEE DETAILS ~ &ffi FOR CONTROL AND EXPANSION JOINTS. 3. FINISH TO BE L~CID ETCH, TOP SURFACE RETARDER TO BE HUB #1. 4. ALL TOP SERVICES TO HAVE WATER BASED CONCRETE SEALER APPLED, ONE (1) COAT P.I.P. ACID ETCHED FLATWORK-Section NOTTO SCALE 1'-0" 2 G ,: ~ :z !o >-" "' Cl "' ::l: :c ~ :z :;: :z "' ~ "' Cl ::l: 3 11/4" O.D. SCHEDULE 40ALUMINUM PIPE RAIL WELD JOINTS AND GRIND ALL SMDOTI-1. PIPE RAIL FINISH TD BE SATIN POWDER COAT, COLOR TO BE BLACK. CONCRETE STAIRWAY, SEE DETAIL ffi CORE CONCRETE AND FILL VOIDS WITH NON-SHRINK GROUT SUCH AS POR-ROK OR EQUAL. FILL VOID LEVEL DEEPENED POUR CONCRETE FLATWORK 18" BEYOND LAST STAIR RISER AND 12" WIDE. TREAD WIDTH + 12" 1 '-0" @1-"-'~ca;;..A;;;,. 1 ~;.:;~;..;. 1 f.;:..,, ~_:.:\.;:..~ 0 ;.,,f::;,,;.I_S;.,.T_A_IR_S _________________ _ 4 -~ '·'· a:'<¥··; • . .d •'. .•. 8 1'-0" • .. ,. ... ·;;,,,, • le -· , I • .(I ~-. .r, . .. 2 3 M ... 4 ~ -.... • ··• NOTE: 4 5 6 • 1. FOR NUMBER OF STEP RISERS, SEE PLAN 1'-0" 7 DJ 1/2 RADIUS AT STEP NOSE, TYPICAL [I] 4" DEPTH OF COMPACTED CLASS 11 BASE [I] #3 REBAR CONTINUOUS AT EAOH STEP NOSE, TYPICAL. [I] COMPACTED NATIVE SOIL, SEE GEOTECHNICAL REPORT. [I] 1/2" POLYETHYLENE EXPANSION JOINT WITH 1/2' X 112" [I] #3 REBAR@ 12" O.C. BOTH WAYS, TYPICAL CAULKING CAP. CAULKING TO MATCH SURROUNDING CONCRETE COLOR [[] P.I.P. CONCRETE STEPS [TI DECORATIVE CONCRETE PAVING, SEE CONSTRUCTION LEGEND. []] SEE DETAIL EB FOR COLOR AND FINISH. P.I.P. CONCRETE STEP -Section Scale: 111 ;:::; 1'-011 97" ' EQ. EQ. 1.,------=~ ~ ~ rr . 1-----------4------------< , 2 f--------t--t-l========a-i===-=--~~ ---===1 3 t----------t• ic~------= 4}----+e::==== s}-----H~~~~~;;;t F----=====a 127- fil~ ~ Niec---,,,,=====&>=,_ 1 _=='---l=======t , - NOTES: § ., j ' . ' [D 2 3 4 12 13 2 ~ Q] FINISH SURFACE r,;i 118" WIDTH SAWCUT L':J JOINT NOTES: ... 1 q 17 • ' •• ~ REBAR, SEE DETAIL® r,j7 FOR BASE MATERIAL, AND ffi L:'.J SUBGRADE SEE DETAIL \V . . . . ' 2 • • -1 \ : q 17 • : •• -"" . . . ' . . ',ll· I : .' ' .. . . . ·i_;, · .•. : ·.: '. . . -~--.. 1. WEAKENED PLANE JOINTS ARE TO BE LOCATED PER PLAN, SEE CONSTRUCTION PLAN. WEAKENED PLANE JOINT SAWCUT -Section NOTTO SCALE l 1 11 10 3'-211 GATE ELEVATION 13 .. l 1 GENERAL SPECIFICATIONS: OJ PCSTCAP [I] 2" X 6" X 95" TOP AND BOTTOM RAILS II] 5" X 5" POST [_D 7/8" X l' X 96' PICKETS [a] 2" X 4" MID-BRACE [a] FINISH GRADE r,i CONCRETE FOOTING, CONCRETE TO ATTAIN L7J 2000 PSI COMPRESSIVE STRENGTH AT 28 DAYS MIN. [a] SUBGRADE TO BE COMPACTED TO A MIN. OF 90% 0 3/4" CRUSHED GRAVEL ~ FINISH SURFACE !JD ALLOW 1" GAP FOR HINGE AND 3/4" GAP FOR LATCH SYSTEM ~ 2" x 4" GATE UPRIGHTS @J SELF CLOSING AND SELF LATCHING GATE HARDWARE ",,)~1111~IT~1111 Ill.., .. llll:- 1'-011 1. THIS FENCE AND GATE AREA PART OF A VINYL FENCING SYSTEM MANUFACTURED BY CERTAINTEED. TEXTURE: CEDAR COLOR: ARCTIC BLEND PICKET STYLE: 7/8" X 3' PICKET SPACING: 21132" 9 FENCING SECTION· ELEVATION THE MODEL IS TO BE BREEZEWOOD SELECT CEDAR. 2. INSTALLATION ISTO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 3. DO NOT SCALE DRAWING. HORIZONTAL VINYL FENCING· Section ca e: 1/2 = 1'-0" STEEL INSERT IN BOTTOM RAILS STEEL INSERT IN TOP RAILS FOR-CLAY, ARCTIC BLEND, BRAZILIAN BLEND, SIERRA BLEND, WEATHERED BLEND I,\ v',>OSCAp~-.... ~T ~~ ~ ~¾ ·~ ,·~ u... BILI! * /"'Jewal ~~ * \V 7-8-21 u'I DBIB /~ ;, " ./£ "l?t OF Cf>.l.l'< G FINISH SURFACE 1-~l FOR BASE MATERIAL AND~ u SUBGRADE SEE DETAILS \V Q] REBAR SEE DETAILS EB iol POLYETHYLENE BACKER ROD, L':J 5/8" DIA. r;] 2'-0" LONG #3 SMOOTH DOWEL iol CAULKING TO BE SIKAFLEX BY SIKA, L:'..i SET@18"0.C.. l]l 1/2"POLYETHYLENE L'.J EXPANSION JOINT, LOCATE PER PLAN. L.::J COLOR TO MATCH CONCRETE. INSTALL PER MANUFACTURER SPECS. JOINT TO BE 1/2" WIDE AND 1/2" DEEP. SPRINKLE #30 GRIT SILICA SAND ATOP AT THE TIME OF INSTALLATION. 1 2 3 . . . . . ... · . . 7 4 5 : . . 6 fo\>--=EX:...:;P:...:.'A_:.:N..:..:S::..:.10-=..:....:Nc..::Jc...::O-=..:IN-'-T'---S::cec:..:c=ti=on-'-------------------V NOT TO SCALE APPROVED FOR /RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUILT" ~=·=--====.11·=,-. === ==,,,.,,,,. APPROVED i DATE RCE EXP. /·~r'»~,1~-rR 1iJr"T~ON SET lff ""'' -'!. <\,,,i, I """' 1 , · -1 REVIEWED BY: I I ' =·-----~ .. -.. ----·-I INSPECTOR DATE I SH~ET I CITY OF CARLSBAD m PLANNING DIVISION 2 LANDSCAPE IMPROVEMENT PLANS FOR: HEMLOCK COAST HOMES 320 HEMLOCK AVENUE, CARLSBAD, CA CONSTRUCTION DETAILS APPROVED:,.?6 A{ J ,/4+/2-, , ,.., PLANNING " OWN BY: '" PROJECT NO. DRAWING NO. 2725 jeff'enioo street, BUiie 150 carlebl:ld, t:a 9200EI phone: 760,720,9337 DATE INITIAL REVISION DESCRIPTION DATE INITIAL DATE INITIAL CHKD BY: JSS RVWDBY: LPC2021-D012, PUD2020-0001 530-SL fa,c: 780,720.9505 Expiraliori Date: 4/30/23 DESIGNER OF WORK OTHER APPROVAL CITY APPROVAL PLOT DATE: 718/21 2021-03-30_Hemlock Homes 1ille Block.vwx .72 1.24 1.41 (J) V --/ / ' < □.,h D WIRELESS IRRIGATION WEATHER SENSOR DEVICE TO BE INSTALLED ALONG TOP EDGE OF WALL OR FENCING WHERE INDICATED. SENSOR TO BE FULLY EXPOSED TO OPEN SKY AND SHADE PROJECTION IF AT ALL POSSIBLE, WIRELESS IRRIGATION WEATHER SENSOR DEVICE TO BE INSTALLED ALONG TOP EDGE OF WALL OR FENCING WHERE INDICATED. SENSOR TO BE FULLY EXPOSED TO OPEN SKY AND SHADE PROJECTION IF AT ALL POSSIBLE, TYPICAL H,, ..... --~--~-~~--~l-l TYPICAL 1.22 I ,--1 ---.JD - - - - ---- - -_r --(J)-- I : ~4 I \ :,;-:--w ---w ---w ---w ---w --- : I ' ' ' '} ! ) I 1 ]\f r , \\ ~ 1" -i-' ! L'ff9-lcl:-'111fTI~it:3/=4::i-------------c---------~-------------- IT --J I ~:t=-----,=-====t• =-------3/4 INSTALL ONE (1) GATE VALVE AND ONE (1) MASTER VALVE FOR EACH POINT OF CONNECTION AT THIS LOCATION. POC #1, 1" POTABLE WATER METER SERVICE, STATIC WATER PRESSURE IS 86 PSI, MAX. GPM FLOW DEMAND IS 4.17 AND STREET STATION > NUMBER IS STA. 9+74.64-10.21 RT. / --------~ POC #2, 1" POTABLE WATER METER SERVICE, STATIC WATER PRESSURE IS 86 PSI, MAX GPM FLOW DEMAND IS 4.17 AND STREET STATION NUMBER IS STA. 9+72.14-10.22 RT POC #3, 1" POTABLE WATER METER SERVICE, STATIC WATER PRESSURE IS 86 PSI, MAX. GPM FLOW DEMAND IS 4.17 AND STREET STATION NUMBER IS STA. 9+77.14-10.22 RT. POC #4, 1" POTABLE WATER METER SERVICE, STATIC WATER PRESSURE IS 86 PSI, MAX. GPM FLOW DEMAND IS 4.17 AND STREET STATION NUMBER IS STA. 9+79.64-10.23 RT. DIAL TOLL FREE 1 • 800 • 422 • 4133 AT LEAST TWO DAYS BEFORE YOU DIG II------: -1 n- tf!/..ia.=j;;;::-w --~, w ' G -~Z G --- UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA 1" I +--- 1 I I ; I 1/,::1/ I ---I - - -_J c .72 IRRIGATION CONTROLLER 'C' TO BE MOUNTED ON FACE OF INTERIOR WALL. MOUNT CONTROLLER BOX AT EYE LEVEL. PROVIDE GROUNDED 110 VAC POWER SOURCE, SEE ELECTRICAL DRAWINGS. IRRIGATION CONTROLLER 'D' TO BE MOUNTED ON FACE OF INTERIOR WALL. MOUNT CONTROLLER BOX AT EYE LEVEL PROVIDE GROUNDED 110 VAC POWER SOURCE, SEE ELECTRICAL DRAWINGS. IRRIGATION MAINLINE AND LATERAL LINES AND HARDWARE ARE SHOWN OUTSIDE OF PROPERTY LIMITS FOR GRAPHIC CLARITY ONLY. IN ALL CASES THE PIPING AND HARDWARE ARE TO BE ~-.., INSTALLED WITHIN THE PROJECT'S PROPERTY LIMITS. SEE DETAILS AND NOTES FOR ADDITIONAL DIRECTION REGARDING THE INSTALLATION OF THESE MATERIALS. IRRIGATION CONTROLLER 'B' TO BE MOUNTED ON FACE OF mrnlml--+-+itt----t------1 INTERIOR WALL MOUNT CONTROLLER BOX AT EYE LEVEL, PROVIDE GROUNDED 110 VAC POWER SOURCE, SEE ELECTRICAL DRAWINGS. I I I 1." -.-.. --- G- " 4.40 3/4" IRRIGATION CONTROLLER 'A' TO BE MOUNTED ON FACE OF INTERIOR WALL. MOUNT CONTROLLER BOX AT EYE LEVEL. PROVIDE GROUNDED 110 VAC POWER SOURCE, SEE ELECTRICAL DRAWINGS. WORST HYDRAULIC CONDITION CALCULATION Remote Control Valve: B-2 Maximum GPM Demand: POC/Water Meter: 1" Available Pressure Static: HGL NA Elevation of Meter. 56.0' Elevation of Valve: 56,4' MAINLINENALVES: 38' L.F. of Service Line" 1" Water Meter 1" Backflow Device 3/4" Filter 1" Master Valve Flow Meter 3/4" Pressure Regulator/Filter 1" Gate/Ball Valve 35' L.F. of Mainline 1" 3/4" Control Valve Misc. Fitting Loss (10%) Subtotal MalnllneNalve PSI Loss: LATERAL LINES: 20' LF. of 3/4" Lateral@ 21' L.F. of 3/4" Lateral@ ___ L.F. of 3/4" Lateral@ ___ L.F. of 3/4" Lateral@ ___ L.F. of 3/4" Lateral@ ___ L.F. of 3/4" Lateral@ Loss Thru Fittings (10%) Subtotal Lateral Line PSI Loss: Total Elevation Change Loss or Gain (psi) Subtotal System PSI Loss: TOTAL PRESSURE AVAILABLE: SUBTOTAL SYSTEM LOSS: PRESSURE REQUIRED AT HEAD: TOTAL PRESSURE LOSSES: RESIDUAL WATER PRESSURE: BOOSTED PRESSURE: BOOSTED RESIDUAL: GPM 4.40 4.40 4.40 4.40 4.40 4.40 4.40 4.40 .95 4.40 15.81 21.80 = = = = = = = = = = = = = = = = = 4.40 86 LOSS .07 0 9.00 .50 2.25 .50 0 .19 1.50 1.40 15.41 .09 .12 ,02 .23 .40' .17 (L) 15.81 86 36.51 49.49 NA NA IRRIGATION HEAD LEGEND NOZZLE ARC & SPECIALTY NOZZLES 360' 270'·210' 210·-so· 45' ADJ, LCS RCS ss DRIP DESCRIPTION MANUFACTURER TECHLINE CVXR 60" DIA. DRIP RING TECHLINE HCVXR DRIPPERLINE NETAFIM TLHCVXR5-12XX NETAFIM TLHCVXR5-12XX IRRIGATION EQUIPMENT LEGEND SYMBOL MANUFACTURER .1111111 HUNTER 0 HUNTER 8 HUNTER ~ SPEARS IRPBI SEE CIVIL DRAWINGS ANY --ANY ® NETAFIM ® NETAFIM [;iii NETAFIM -----NETAFIM POC IWMI SEE CIVIL DRAWINGS @ HUNTER DESCRIPTION 6 STATION IRRIGATION CONTROLLER WI INTERIOR RATED WALL MOUNT ENCLOSURE ANTI SIPHON REMOTE CONTROL VALVE 314" MASTER REMOTE CONTROL VALVE 1" MANIFOLD TRUE UNION BALL VALVE PROPOSED REDUCED PRESSURE BACKFLOW, SEE CIVIL DRAWINGS LATERAL LINE, TYPE 1120 PVC PIPE, SCH. 40 IRRIGATION MAINLINE PIPE PVC SCH. 40 314"-1 112' PVC CLASS 315 2"+ 120 MESH DISC FILTER WNALVE PRESSURE REGULATOR VALVE OPERATION DETECTION FLAG BLANK TECH LINE TUBING POINT OF CONNECTION NEW PROPOSED WATER METERS, SEE CIVIL DRAWINGS WIRELESS WEATHER SENSING DEVICE VALVE CALLOUT LEGEND ----STATION I.D. DESIGNATION ~ DRIP CIRCUIT REGULATOR SIZE ~-+~-=-,a-ccc.r{ct-=6.5~0 ---GALLONS PER MINUTE 3/~ ~ DRIP CIRCUIT FILTER SIZE '---CONTROL VALVE SIZE 10 0 ~ SCALE: 1"=10'-0'' 5 I 10 20 I I MODEL NO, RAD MODEL NO. IC-600PL PGV-075-ASV ICV-101G TU 2000/3629 SEE CIVIL DRAWINGS DFXXX-120 WRPRl-40 10-F-01 TLRW SEE CIVIL DRAWINGS WSS-SEN NOTES: GALLONS PER MINUTE PSI IPH 360' 270'-210' 210' INCHES/HR 40 0.53 40 0.53 REMARKS CONTRACTOR TO INSTALL PER MANUFACTUER'S SPECIFICATIONS. MATCH MAINLINE SIZE AT CONTROL VALVE MANIFOLD FEED. INSTALLED BY OTHERS SEE CIVIL DRAWINGS SEE DRAWi NGS FOR Pl PE SIZING SEE DRAWi NGS FOR Pl PE SIZING SEE VALVE CALLOUT FOR SIZE SPECIFICATION INSTALLED BY OTHERS SEE CIVIL DRAWINGS MOUNT SENSOR ON TOP EDGE OF BLOCK WALL. CONTRACTOR TO INSTALL PER MANUFACTUER'S SPECIFICATIONS 180' 90' 1. THIS IRRIGATION DESIGN IS BASED UPON A MINIMUM OPERATING PRESSURE OF78 PSI WITH A MAXIMUM DEMAND OF 4.17 GPMATTHE POINT OF CONNECTION. 2. AVAILABLE CITY STATIC WATER PRESSURE IS 86 PSI. 3. THIS PROJECT IS LOCATED WITHIN THE JURISDICTION OF THE CARLSBAD MUNICIPAL WATER DISTRICT, PH. 760-438-2722. 4. ALL END LINE OR UNMARKED LATERAL LINE PIPE SIZE SHALL BE 3/4" SCH 40 PVC, UNLESS OTHERWISE NOTED, NO 112' PIPE IS TO BE USED. 5. TYPICAL FOR ALL DRIP IRRIGATION TUBING, LINE SPACING FOR SHRUB BEDS TO BE 14" O.C. AND 12" FOR TURF. DRIP PER SPACING TO BE 12" IN ALL CONDITIONS. 6. CONTACT MR. BILL MILLWARD WITH NETAFIM USA REGARDING THE INSTALLATION OF ALL NETAFIM HARDWARE, OR TO SETUP A PRECONSTRUCTION MEETING, PH: (951) 2B7-4630. 7. DEEP WATERING TREE RING CIRCUITS SHALL NOT BE CONNECTED TO SHRUB DRIP CIRCUITS, IN MOST INSTANCES SOME TREE CIRCUITS ARE GRAPHICALLY SHOWN OUTSIDE OF PLANTER BEDS FOR GRAPHIC CLARITY ONLY. 8. ALL MAINLINE AND LATERAL LINE PIPE LOCATED BELOW PAVED SURFACES ARE TO BE PLACED WITHIN A SCH. 40 PVC PIPE THAT IS 2 X THE SIZE OF THE PIPE IT IS CARRYING. 45' 9. MAINLINE PIPE SHOWN OUTSIDE OF THE PROPERTY LIMITS IS FOR GRAPHIC CLARITY ONLY, ACTUAL MAINLINE PIPE LOCATION IS TO BE WITHIN BE WITHIN THE PROPERTY LIMITS INALL CASES/ DETAIL U6 J/5 M/4 DETAIL A B/5 C,D/5 K/6 D/5 K,016 E D/5 H 115 H 115 F/5 F/5 N/6 M/6 B/5 APPROVED FOR /RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE 40 ! FEET LOCATION OF PLANTING AREA. "AS BUILT" RCE---EXP. DATE REVIEWED BY: INSPECTOR DATE 1----+--+------------+--+----+---+------'~ CITY OF CARLSBAD ~ PLANNING DIVISION [siimsl l__1_2_J 2125 J11fferso11 11treel, &LIiie 15b carleb11d, ca 92008 pllor,a: 760,720.9337 fax: 760.720.9505 ~-------------1 LANDSCAPE IMPROVEMENT PLANS FOR: 1/ Ex iration Dale' 4/30/23 HEMLOCK COAST HOMES 320 HEMLOCK AVENUE, CARLSBAD, CA IRRIGATION PLAN I----+---+---------+---+----+------!--~ I APPROVED: A A.f,L l---+---1-----------------+---+---l---1---1 ~~-P=LA=cN"'N_l':'N_G=:_=-=-=-~;;,_;::::_=--.::;-;:-=-=~-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=_:;;=====:; DWN BY: JSS PROJECT NO. DRAWING NO. 530-SL CHKD BY: JSS RVWD BY: LPC2021-0012, PUD2020-00D1 DATE INITIAL DESIGNER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHERAfJPROVAL CITY APPROVAL PLOT DATE: 7/8121 2021-03-30_Hemlock Homes Title Block.vwx 0 IRRIGATION CONTROLLER NOTTO SCALE 2 4 CD 0 0 0 IRRIGATION CONTROLLER (I-CORE) PER PLAN IRRIGATION CONTROLLER WIRES PLACED IN CONDUIT, SIZE AND TYPE PER LOCAL CODES PLUG AND PIGTAIL POWER CONNECTION MOUNT CONTROLLER TO WALL STUD AS REQUIRED NOTE: 1. MOUNT CONTROLLER'S LCD SCREEN AT EYE LEVEL [2] PVC BALL VALVE 0 BRICK OR CONG. SUPPORTS 0 COMPACTED SUBGRADE ALL AROUND 0 INTEGRAL UNION (TYP.) ~ PVC MALE ADAPTER (TYP.) ~ 2" IN G.C. FLUSH IN LAWN 0 1 O" CIRCULAR PLASTIC VALVE BOX WI 0 TURF BOLT DOWN COVER, GREEN COLOR. G SEE DETAIL 115 USE STAINLESS STEEL BOLT AND 0 FINISH GRADE WASHER. HEAT BRAND BV ONTO @] 1 CU. FT. PEA GRAVEL (MIN.) LID COVER. 0 PVC MAINLINE (TYP,) 0 PVC BALL VALVE NOTTO SCALE I,] PVC NON PRESSURE LATERAL LINE, PLACE WITHIN LJ SCH. 40 PVC CONDUIT WHEN LOCATED UNDER PAVED SURFACES io7 PVC PRESSURE PIPE, PLACE WITHIN SCH. 40 PVC L:J CONDUIT WHEN LOCATED UNDER PAVED SURFACES io7 CONTROL WIRE BUNDLE. USE THHNffHWN (THINNER l:J JACKETI, PLACE IRRIGATION CONTROL WIRE WITHIN COMMON MAINLINE TRENCH AND TAPE TO BOTTOM OF MAINLINE PIPE WITH PVC TAPE EVERY 10' O,C, VARIES 6i----ttt~±tet~ r:;"J PIPE ZONE BEDDING ~ BACKFILL, BACKFILL TO BE SAND. 0 UNDISTURBED SOIL @] 0 NATIVE SOIL BACKFILL, COMPACT PER IRRIGATION NOTES SOIL FILTER FABRIC 0 FINISH GRADE !al SEE NOTES BELOW l':'J FOR DEPTH io7 CHRISTY'S 3" WIDE POTABLE L.:J WATER MARKING TAPE, MODEL# TA-DT-3-BPW. TOP OF MARKER TO BE LOCATED 12" BELOW GRADE IN LANDSCAPECONDITION AND 6" MAX.BELOW PAVED SURFACES. NOTES: 0 TRENCH UNDER LANDSCAPE AREAS: MAINLINE: 18" NON-PRESSURE LINE: 12" :~===:=-......:.1,~;~z~~:r2t~1,,;~i·t 0 TRENCH UNDER PEDESTRIAN PAVING MAINLINE: 18" NON-PRESSURE LINE: 18" TRENCH UNDER VEHICULAR PAVING 9 2 I ==·•-• .-·"/,; :: ~; _.. • .::.: -' -·:.\ ·•·.-. ' :>~: !~' -~.:_)_, :--~·_::':~,~---•, .. _______ _,,,_ 0 TRENCH WITH PIPE & WIRES NOTTO SCALE • MAINLINE: 36" NON-PRESSURE LINE: 36" 5 0 WEATHER SENSOR NOTTO SCALE i.---lUP TO 800' AWAY-----! ~ ' --(D (7\ MODEL: WIRELESS SOLAR SYNC SENSOR, \,_'.,I MOUNT UP TO 800' FROM RECEIVER r;;-\ INSTALL ON FACE OF SITE WALL OR FENCE, MIN. \..V HEIGHT ABOVE GRADE IS TO BE 12', MOUNT IN LOCATION WHERE SENSOR CAN RECEIVE FULL SUN, IS OPEN TO RAINFALL AND OUT OF SPRINKLER SPRAY PATTERN G) HUNTER I-CORE CONTROLLER 0 VALVE CONTROL WIRE CONDUIT ® POWER SOURCE [2] TECHLINE DISC FILTER 0 PVC SCH. 80 UNION (TxTI 0 314" PEA GRAVEL SUMP fel BRICK SUPPORT, MIN, ~ 6" X 6" (TYP.) PVC FEMALE ADAPTER 2" IN G.C. & 1" IN LAWN AREAS 0 PVC MAINLINE (TYP.) PLASTIC RECTANGULAR VALVE BOX 0 WI BOLT DOWN COVER, COLOR TO BE GREEN. USE STAINLESS STEEL BOLT AND WASHER. HEAT BRAND DRIP ONTO LID COVER. 3 1~1"1Jill I Ill 5 0 6" MIN. CLEARANCE FINISH GRADE fel NETAFIM PRESSURE ~ REGULATOR SOIL FILTER FABRIC 0 SCH, 80 PVC MALE ADAPTER CHRISTY'S RECLAIMED WATER TAG 12 NETAFIM DISC FILTER W/ PRESSURE REGULATOR IN BOX [2] 0 0 NOTTO SCALE TECHLINE 0 DRIPPER LINE TECHLINE TUBING 0 BARBED ELBOW FINISH GRADE 0 2 5 6 7 BLANK TECHLINE TUBING TECH LINE 314" BARBED MALE ADAPTER PVC SCH 40 TEE (SxSxTI 8 11 ® w-+------,11 10 G7 PVC OR BLANK TECHLINE TUBING LATERAL L'J HEADER OR FOOTER, SEE DRAWINGS 0 EMISSION POINT 0 3" ~ 10" 6" GALV. WIRE SOIL STAPLES INSTALLED AT 4' O.C. FOR TUBING, PLUS TWO (2) ON EACH TEE, ELBOW, OR CROSS. TO BE INSTALLED ON SURFACE MOUNTED TUBING AS WELL TECHLINE START CONNECTION SUBSURFACE ELL NOTTO SCALE 2 7 DJ ANTI-SIPHON REMOTE CONTROL VALVE m 18-24" COILED WIRE []J WATERPROOF CONNECTORS (2) m SCH. 40 UVR PVC PIPE & FITTINGS [I] FINISH GRADE []] MAIN LINE PIPE & FITTINGS IT] LATERAL PIPE & FITTINGS []] SCH. 40 UVR PVC MALE ADAPTOR, MIPT X SOCKET (4) NOTE: 1, ANTI-SIPHON VALVES ARE TO BE INSTALLED 12" MIN, ABOVE THE HIGHEST SPRINKLER HEAD WITHIN THE IRRIGATION CIRCUIT IT IS ATTACHED TO. CHECK LOCAL CODES TO CONFIRM THIS INFORMATION. ANTI SIPHON REMOTE CONTROL VALVE NOTTO SCALE [j] WATERPROOF ELECTRICAL CONNECTORS [I] SEAL CONDUIT ENDS WI SPRAY FOAM IT] PLASTIC RECTANGULAR VALVE BOX WI BOLT DOWN COVER, GREEN COLOR. USE STAINLESS STEEL BOLT AND WASHER. HEAT BRAND "PB" ONTO LID COVER. ~ NOTES: 1. VALVE BOXES SHALL BE LOCATED WITHIN PLANTING BEDS. 2. WIRE SPLICES SHALL ONLY BE MADE WITHIN ELECTRICAL PULL BOXES. 7 [D 2" IN G.C.AREASAND 1" IN LAWNS IT] CONTROLLER WIRES WIJH 24" MIN. EXPANSION CURLS IT] 314" GRAVEL SUMP 0 BRICK SUPPORT, ONE (1) ON EACH CORNER PULL BOX & CONTROL WIRE SPLICE NOTTO SCALE 2725 Jeff arson street, suit a 15b carlebed, ca 92000 phone: 780,720,9337 fax: 760.720,9505 \)-\'IDSCAp~ ~ ~~ ~ a,0 .. ,~~ ~,\; "I "' -C) ~ "' ( I /l%J:l'.'23 * 1,.enewa! Dal& * \ 7.R.?1 / <l';,. '-.... o,,. 4'!" -1~ OF c~1'<0 Expiration Dale: _A13ill.23__ [I] SCH. 40 PVC CONDUIT, SIZE AS REQUIRED [9J FINISHED GRADE OQ] SOIL FILTER FABRIC, WRAP AROUND BRICK SUPPORTS 1 Ii\ DATE INITIAL DESIGNER OF WORK [2J PRESSURE SUPPLY LINE (SEE PLAN FOR SIZE) 0 BALL VALVES (SEE DETAIL EIS) 0 QUICK COUPLER N ~ NOTES: 1. CENTER BOX OVER REMOTE CONTROL VALVE TO FACILITATE SERVICING. 2. SET RCV AND VALVE BOX ASSEMBLY WITHIN GROUND COVER/SHRUB AREA WHENEVER POSSIBLE. INSTALLIN LAWN AREA ONLY IF GROUNDCOVERAREA DOES NOT EXIST ADJACENT TO LAWN. r:;"J HEAT BRAND ALL VALVE BOXES, 1-112" HEIGHT L:J LETTERING MINIMUM ,;;-J REMOTE CONTROL VALVE AND l':'J BOX Q EDGE OF LAWN, WALKWAY, CURB, l':'J FENCE, ETC. ~~ 6 18" 3. SET BOXES PARALLEL TO EACH OTHER AND PERPENDICULAR TO EDGE. 4. AVOID HEAVILY COMPACTING SOIL AROUND VALVE BOX EDGES TO PREVENT COLLAPSE AND DEFORMATION OF THE VALVE BOX SIDES. VALVE MANIFOLD CONFIGURATION NOTTO SCALE [2] BASE, PER CIVIL DRAWINGS 0 PAVING SURFACE . " : . ·,_. ·. ·. ~-. 2 Ill 1111 , 1111= PIPE SIZE 1/2" TO 4" IN SIZE NOTES: 0 LATERAL LINES IN SCH 40 SLEEVE ,:;7 CHRISTY'S 3" WIDE POTABLE L:J WATER LINE WARNING TAPE, #TA-DT-3-BPW A B C D SEE DETAIL 4" 1/3 FOR DEPTH 12" 4" 1. PVC SLEEVES TO BE 2X THE DIAMETER OF THE PIPE OR WIRE BUNDLE CARRIED. 2. ALL MAINLINE, LATERAL LINES, AND CONTROL WIRES ARE TO BE PLACED WITHIN I j ,;;-J CONTROL WIRES IN l':'J SCH 40 SLEEVE 0 UNDISTURBED SOIL 177 PRESSURE MAINLINE L'J IN SCH 40 SLEEVE PIPE ZONE AND BEDDING 0 BACKFILL, BACKFILL TO BE SAND, E 3" SCH. 80 PVC SLEEVES WHEN INSTALLED UNDER ROADWAYS AND SCH, 40 SLEEVES WHEN PLACED UNDER PAVING (NON-ROADS). ® SLEEVING H NOT TO SCALE APPROVED FOR /RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUILT" ;tf\PPROVED DATE RCE EXP. ('''("\\~' [llf'1rRUCTION U\l"' .... t:c_-:.!J ,. ' , Jq.z:;;'.¥ I ' , • ~ SET REVIEWED BY: . ~---- INSPECTOR DATE I SH~ET I CITY OF CARLSBAD ~ PLANNING DIVISION 2 LANDSCAPE IMPROVEMENT PLANS FOR: HEMLOCK COAST HOMES 320 HEMLOCK AVENUE, CARLSBAD, CA IRRIGATION DETAILS /..) APPROVED: af£. -164L"L, ,v-c \ . PLANNING , If OWN BY: JSS PROJECT NO. DRAWING NO. REVISION DESCRIPTION DATE INITIAL DATE INITIAL CHKD BY: JSS RVWD BY: LPC2021-0012, PUD2020-0001 530-5L OTHER APPROVAL CITY APPROVAL PLOT DATE: 718121 2021-03-30_Hemlock Homes Trtle Block.WIX ~ PVC LATERAL LINE, G NETAFIM TECHLINE CV, 0 NETAFIM TECHLINE SIZE PER PLAN, SEE 30" DIA. DRIP RING. CENTER DRIPPERLINE EMITTER DETAIL 113 ON TREE TRUNK. INSTRUCTIONS: 0 0 TREE TRUNK 0 NETAFIM TECHLINE, [!] STRIP WIRES APPROXIMATELY 112" (12.7mm) INSERT WIRE ASSEMBLY INTO PLASTIC TUBE SCH. 80 PVC TEE, SXSXFPT 18" DIA. DRIP RING. CENTER TO EXPOSE WIRE. 0 UNTIL WIRE CONNECTOR SNAPS PAST LIP IN ON TREE TRUNK. BOTTOM OF TUBE. NETAFIM COMBINATION TEE TWIST CONNECTOR AROUND WIRES 0 SCH. 80 PVC RISER 0 MODEL# TL075FTEE 0 CLOCKWISE UNTIL HAND TIGHT. DO NOT ~ PLACE WIRES WHICH EXIT TUBE IN WIRE EXIT BLANK TECHLINE TUBING OVERTIGHTEN. 0 HOLES CLOSE CAP UNTIL IT SNAPS. INSPECT FINAL SPLICE ASSEMBLY TO BE §] NETAFIM INSERT TEE @] SECURE AND FINISHED. MODEL #TLTEE 3 ~ 0 ~)))1))))))))))))11))11 ~ .(?b :' \~ -.• 0 0 @] ,. ,·. ' .. mii ::.· 7 6 PLAN VIEW SECTION WATER PROOF WIRE CONNECTORS TECHLINE CV DRIP RING • SMALL Below Grade A lication NOTTO SCALE NOTTO SCALE DJ REMOTE CONTROL VALVE, PER LEGEND 0 PVC MAINLINE @] FINISH GRADE [I] PLASTIC RECTANGULAR VALVE BOX IT] SCH. 80 PVC SxS ELL ~ 2" IN G.C. & 1' IN LAWN AREAS WI BOLT DOWN COVER, GREEN COLOR. USE STAINLESS STEEL BOLT, WASHER. 0 WATER PROOF CONNECTORS @) 2" MINIMUM HEAT BRAND RCV AND CONTROL STATION @) # ONTO LID COVER. ~ CONTROL WIRES WI 18' REFER TO TRENCHING DETAIL PIGTAILS, GAGE AS REQUIRED OJ SCH. BO PVC UNION @) 1 CU. FT OF PEA GRAVEL @] BRICK SUPPORTS, ONE (1) AT [I] SCH. BO PVC NIPPLE (TYP.) EACH CORNER @] SOIL FILTER FABRIC, WRAP TWICE AROUND BRICK SUPPORTS IT] SCH. BO PVC MALE ADAPTER @] COMPACTED SUBGRADE @] CHRISTY'S VALVE I.D TAG IT] PVC LATERAL LINE REMOTE CONTROL MASTER VALVE NOTT S ALE ~ 0 0 G TECHLINE 0 DRIPPER LINE EMISSION POINT ~ 4"-6" FROM PAVING PVC PIPING 0 START CONNECTION ~ DIMENSION PER PLAN (MAINTAIN AND FITTINGS, SEE DRAWINGS SEE DETAILJ/5 TRIANGULAR SPACING OF 0 EMMITERS) TRIANGULATE EMITTERS EXHAUST HEADER OUTLETS SOURCE TO HEADER 0 LINE FLUSHING VALVE WI El BLANK TECHLINE TUBING, SEE GRAVEL SUMP, IF SPECIFIED @J DRAWINGS 11 EJ 9 3 0 10 0 ·~ / 0 0 / l l ff 1 ® 1 0 9 NETAFIM DRIP TUBING SAMPLE LAYOUT NOTTO SCALE 2725 Jefferson street, suite 15b carl9bed, ca 92008 phono: 760,720.9337 fax: 760.720.9505 REMOTE CONTROL VALVE ® EQUAL DIMENSION 1 l:.' 2 4 @] 6 f 7 LF 8 ,,sOS -:::::::-.. ' 'fff ~'"{ Sc-~,.,,. . '¾"i !:! --;, I ~ t ~ -< I I.I'~· * -23 * /~nMalDate \ 7-A-°' I ,s,;::...__ Do>o ,.-0 ;g-?.ii~ &-.~ OFC/',\.I~ DATE INITIAL Expiralion Date: 4130123 DESIGNER OF WORK ~ OPERATION FLAG @] BRICK OR CONG. SUPPORTS ~ COMPACTED SUBGRADE ALL AROUND 0 SUPER FLEX UV WHITE TUBING 0 BARB X BARB CONNECTOR ~ 2" IN G.C., FLUSH IN LAWNS 0 TURF El SEE DETAIL 115 0 1 O" CIRCULAR PLASTIC VALVE BOX WI BOLT DOWN COVER, COLOR GREEN USE STAINLESS STEEL BOLT AND 0 FINISH GRADE @J WASHER.HEAT BRAND Pl ONTO LID 314" CRUSHED GRAVEL SUMP COVER. G STAKE @] SOIL FILTER FABRIC 8 10 3 El TECHLINE CV TUBING ~ ,-=1111_1111::.1-= :1111-.1111 1111 111 1111 1111 1111111 1111 11111 ~ ~1111 1111 IIIr 1![1111 1111 1111 11 11111 11111111111111111111; 1111_1111_11:1- 1irn111i111= 5 >I -I ~iir ... II 1111= ~ ,1111 1111 Ill /-:::Y "'1![1 JIII-= ;/ 6 II 4 I NETAFIM PRESSURE INDICATOR STAKE NOTTO SCALE APPROVED FOR /RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUILT" I _m __ A\PPR(01VED) ' I DATE ! . RCE EXP . ,,',ri''\'!\ ~1'"""1,=[~U(~"l=~or~ sE-r . ! .,, '·\C\' ~ l I'"' '' ' ' ·-l9 \:~Y fl ~:-, ¼.l j ~l \· · ·. -':I -., ·, u ~-, . REVIEWED BY: INSPECTOR DATE /1\ I SH~ET I CITY OF CARLSBAD ~ PLANNING DIVISION 2 LANDSCAPE IMPROVEMENT PLANS FOR: HEMLOCK COAST HOMES 320 HEMLOCK AVENUE, CARLSBAD, CA IRRIGATION DETAILS I APPROVED: A, I ~ .. --, (J4-,/z.,i ~ PLANNING DWN BY: JSS PROJECT NO. DRAWING NO. REVISION DESCRIPTION DATE INITIAL DATE INITIAL CHKDBY: JSS RVWDBY LPC2021-0012, PUD2020-0001 530-5L OTHER APPROVAL CITY APPROVAL PLOT DATE: 718121 2021-03-30_Hemlock Homes Title Block.vwx IRRIGATION NOTES: 1. THIS PLAN IS SCHEMATIC AND DUE TO THE NATURE OF CONSTRUCTION, SLIGHT FIELD MODIFICATIONS MAY BE NECESSARY TO IMPLEMENT THE DESIGN DEPICTED WITHIN THESE DRAWINGS. 2. PLANS ARE DIAGRAMMATIC AND APPROXIMATE. PRECISE LOCATION OF SPRINKLER HEADS AND DRIPPER LINE SHALL BE FIELD ADJUSTED TO MEET MINOR VARIATIONS IN PLAN. 3. POINT OF CONNECTION (POC) SHALL BE WHERE INDICATED ON THE DRAWINGS. 4. CONTRACTOR SHALL FIELD VERIFY SIZE OF WATER METER BEFORE WORK COMMENCES, MINIMUM SIZE TO BE 1", NOTIFY LANDSCAPE ARCHITECT OF ANY DISCREPANCY. - 5. CONTRACTOR SHALL NOTE LOCATIONS OF TREES ON PLANTING PLAN AND SHALL ROUTE IRRIGATION PIPE AND PLACE HEADS TO PREVENT CONFLICTS WITH TREE PLANTING. GROUP VALVES IN BOXES PARALLEL TO EACH OTHER IN PLANTING AREAS. LOCATE PIPE ALONG EDGE OF PLANTING AREAS WHEREVER POSSIBLE AND WITHOUT CONFLICT WITH OTHER UTILITIES OR BUILT FEATURES. 6. FLUSH ALL PIPES CLEAN PRIOR TO INSTALLING SPRINKLER HEADS AND DRIPPER TUBING. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SLEEVES AND CHASES UNDER PAVING, THROUGH WALLS, ETC. UNLESS OTHERWISE NOTED. ALL SLEEVES ARE TO BE SCH. 40AND TWICE THE DIAMETER OF THE PIPE CARRIED. SLEEVES TO EXTEND AT LEAST 12" PAST THE EDGE OF PAVING. ALL MAINLINE, LATERAL LINES, AND CONTROL WIRES LOCATED UNDER PAVING ARE TO BE PLACED WITHIN A SLEEVE. ELECTRICAL WIRES FOR IRRIGATION VALVES AND IRRIGATION LINES ARE TO BE PLACED IN SEPARATE SLEEVES. 8. CONTROL WIRES SHALL BE BUNDLED WITH ELECTRICAL TAPE AT 10'-0" INTERVALS AND BURIED BENEATH MAINLINE WHEN LOCATED WITHIN PLANTERS. 9. SYSTEM CONTROLLER SHALL BE CONNECTED TO A RAIN SENSOR SHUTOFF DEVICE, SEE DRAWINGS. 10. IRRIGATION SYSTEM IS SHOWN DIAGRAMMATICALLY. LOCATE ALL PIPE AND EQUIPMENT WITHIN ADJACENT PLANTING AREAS. GROUP PARALLEL PIPE IN SINGLE TRENCHES WHERE POSSIBLE. 11. ALL IRRIGATION MATERIALS AND PROCEDURES SHALL CONFORM TO ALL LOCAL, MUNICIPAL, AND STATE LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK AND ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE NOTES AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE IRRIGATION CONTRACTOR. 12. ANY SITE WITH SIGNIFICANT ELEVATION CHANGE WITHIN THE IRRIGATION MAINLINE INSTALLATION (15 FT. OR MORE) SHALL HAVE A CRISPIN AIR-RELIEF VALVE INSTALLED AT THE HIGH POINT WITHIN THE MAINLINE RUN. 13. TRENCHES SHALL BE MADE WIDE ENOUGH TO ALLOW A MINIMUM OF 4" BETWEEN PARALLEL PIPE LINES. STACKING OF PIPES VERTICALLY WITHIN THE SAME TRENCH WILL NOT BE ALLOWED. 14. THE LANDSCAPE CONTRACTOR IS TO FIELD INSPECT ALL SHRUB BEDS BEING IRRIGATED WITH THE NETAFIM TECHLINE CV SYSTEM. EACH BED IS TO BE EVALUATED FOR SOIL TYPE (CLAY, LOAM, OR SANDY) AND DETERMINE IF THE SPECIFIED TECHLINE EMITTER INTERVAL, LINE SPACING, OR DRIPPER FLOW SHOULD BE ADJUSTED ACCORDING TO THE NETAFIM COMPANY'S DESIGN GUIDELINES. CONSULT WITH LANDSCAPE ARCHITECT REGARDING THIS ISSUE PRIOR TO ORDERING NETAFIM TUBING. 15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, EQUIPMENT QUANTITIES, AND UTILITY LOCATIONS PRIOR TO BEGINNING WORK. 16. CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF ANY DISCREPANCIES IN PLANS OR SPECIFICATIONS PRIOR TO BEGINNING OR CONTINUING WORK. 17. THE CONTRACTOR SHALL MAKE NO SUBSTITUTIONS, DELETIONS, OR ADDITIONS TO THIS PLAN WITHOUT WRITTEN APPROVAL OF THE LANDSCAPE ARCHITECT. 18. ALL CONSTRUCTION SHALL CONFORM TO CITY, COUNTY, STATE, AND FEDERAL REQUIREMENTS. THE CONTRACTOR SHALLALSO BE RESPONSIBLE FOR OBTAINING ANY NECESSARY PERMITS OR APPROVALS. 19. IRRIGATION SYSTEMS CONNECTED TO POTABLE WATER SUPPLY SHALL HAVE A BACKFLOW PREVENTER INSTALLED. 20. ANY EXISTING TREES TO REMAIN ARE TO BE PROTECTED FROM DAMAGE. DO NOT TRENCH OR EXCAVATE WITHIN THE CRITICAL ROOT ZONE OF ANY TREE. 21. SHOULD ANY IRRIGATION LATERAL LINES, MAIN LINES AND EQUIPMENT BE SHOWN OUTSIDE PROPERTY LINES ON THIS PLAN, HOWEVER ALL IRRIGATION LINES AND EQUIPMENT ARE TO BE INSTALLED WITHIN THE PROJECT'S PROPERTY LIMITS. 22. ALL WORK CALLED FOR ON THESE DRAWINGS BY NOTES, DETAILS OR PLAN GRAPHICS SHALL BE FURNISHED AND INSTALLED WHETHER OR NOT SPECIFICALLY MENTIONED IN THE SPECIFICATIONS. WHEN AN ITEM IS SHOWN ON THE PLANS, BUT NOT ADDRESSED WITHIN THE SPECIFICATIONS OR VISE VERSA, IT SHALL BE DEEMED TO BE SHOWN ON BOTH. THE LANDSCAPE ARCHITECT SHALL HAVE FINAL AUTHORITY FOR CLARIFICATION IN ALL INSTANCES. 23. ALL VALVES, QUICK COUPLER VALVES AND WIRE SPLICES SHALL BE LOCATED WITHIN PLANTING BEDS WHENEVER POSSIBLE. 24. CENTER LOAD PIPING WITH SUFFICIENT AMOUNT OF BACKFILL TO PREVENT ARCHING OR SLIPPING UNDER PRESSURE. APPLY CONTINUOUS WATER PRESSURE OF THE NUMBER OF POUNDS PER SQUARE INCH SPECIFIED BELOW. (A) PRESSURE LINES TO BE TESTED FOR FOUR (4) HOURS AT 150 PS.I. (B) LATERAL LINES TO BE TESTED FOR TWO (2) HOURS AT 100 P.S.I. REPAIR LEAKS RESULTING FROM THE TESTS AND RETEST UNTIL SYSTEM MEETS ALL SPECIFIED TEST CRITERIA SEE SPECIFICATIONS. ' 25. THE IRRIGATION CONTRACTOR SHALL MAINTAIN A PRE-AS-BUILT RECORD DRAWING DURING THE CONSTRUCTION PHASE OF THIS PROJECT DOCUMENTING ANY DEVIATIONS FROM THE PLAN IN RED INK. THE CONTRACTOR SHALL DELIVER THE PRE-AS-BUILT PLANS TO THE LANDSCAPE ARCHITECT PRIOR TO THE FINAL ACCEPTANCE OF THE SYSTEM. FINAL AS-BUILT PLANS ARE TO THEN BE PREPARED BY THE LANDSCAPE ARCHITECT FROM DIMENSIONS PROVIDED BY THE CONTRACTOR. FINAL AS-BUILT PLANS SHALL BE DRAFTED CLEARLY TO THE SATISFACTION OF THE CITY, AND THE FINAL PLANS SHALL BE SUBMITTED TO THE CITY FOR THEIR KEEPING. THE FINAL AS-BUILT PLANS WILL BE REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND FINAL PLANS WILL BE REQUIRED TO BE SIGNED BY THE CITY PRIOR TO THE RELEASE OF SECURITIES. SEE LANDSCAPE SPECIFICATIONS FOR FURTHER DIRECTION REGARDING THE PREPARATION OF AS-BUILT DRAWINGS. 26. ALL IRRIGATION CONTROL WIRE INSTALLED ABOVE GRADE SHALL BE ENCASED WITHIN SCH. 40 PVC ELECTRICAL CONDUIT 27. THE IRRIGATION CONTRACTOR WILL BE RESPONSIBLE FOR ALL WALLAND CONTROLLER CABINET PENETRATIONS. ALL PENETRATIONS ARE TO BE PROPERLY SEALED TO INSURE THE INTEGRITY OF THE BUILDING'S AND THE CONTROLLER ENCLOSURE'S WATERPROOFING. 28. NO WIRE SPLICES WILL BE ALLOWED FOR ANY WIRE RUN OF LESS THAN 1000 L. F. ALL WIRE SPLICES SHALL BE LOCATED WITHIN A STANDARD SIZED VALVE BOX, SEE DETAILS. WIRE BUNDLES SHALL BE TAPED TOGETHER WITH ELECTRICAL TAPE EVERY 10' O.C. 29. ALL TRENCHING SHALL FALL OUTSIDE OF THE TREE DRIPLINE OF ALL EXISTING TREES AND OUTSIDE OF THE ROOT BALL OF ALL NEWLY PROPOSED TREES. 30. PRIOR TO ANY IRRIGATION PIPE TRENCHING OR HARDWARE INSTALLATION THE CONTRACTOR IS TO REVIEW THE IRRIGATION PLANS AND DETERMINE IF THERE ARE ANY POSSIBLE UTILITY CONFLICTS EXIST. SHOULD CONFLICTS EXIST, THE CONTRACTOR SHALL NOTIFY AND COORDINATE ANY INSTALLATION MODIFICATIONS WITH THE GENERAL CONTRACTOR. THE CONTRACTOR WILL BE RESPONSIBLE FOR DAMAGE TO ANY EXISTING UTILITIES. 31. THE LANDSCAPE CONTRACTOR IS TO MAKE A PART OF HIS CONTRACTUAL SERVICES AGREEMENT FOR THIS PROJECT THE PREPARATION OF THE FOLLOWING: IRRIGATION WATERING SCHEDULE, A WATER AUDIT REPORT, HYDROZONE DIAGRAM AND A LANDSCAPE MAINTENANCE SCHEDULE FOR BOTH LANDSCAPE AND IRRIGATION. ALL DOCUMENTATION IS TO MEET THE MINIMUM STANDARDS DEFINED WITHIN THE CITY OF CARLSBAD'S CURRENT LANDSCAPE DESIGN MANUAL, SEE INSTALLATION AND COMPLETION, SECTION 'D', PAGES 56 -59. 32. SHOULD THE CONTRACTOR IDENTIFY ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND THE SITE CONSTRUCTION PLANS, THE CONTRACTOR IS TO NOTIFY THE OWNER'S REPRESENTATIVE PRIOR TO ANY CONSTRUCTION BEGINNING. 33. THE CONTRACTOR SHALL CLEANUP AND DISPOSE OF ALL DEBRIS, WASTE, AND EXCESS MATERIALS ASSOCIATED WITH HIS SCOPE OF WORK. THIS INCLUDES SWEEPING /CLEANING ALL PAVED SURFACES FOR ON OR OFF-SITE WORK AREAS. 34. THE CONTRACTOR SHALL PROVIDE A ONE (1) YEAR WARRANTY FOR ALL PRODUCTS AND WORKMANSHIP. 35. PROVIDE IN LINE PVC CHECK VALVES OF CORRECT LINE SIZE WHERE FIELD CONDITIONS DEMAND, PER PLANS, AND/OR AS REQUIRED (TO PREVENT LOW HEAD DRAINAGE). CONTRACTOR TO INCLUDE TEN (10) CHECK VALVES OF VARYING SIZES WITHIN BASE BID. 36. ONLY SUBSURFACE IRRIGATION SHALL BE USED TO IRRIGATE ANY VEGETATION WITHIN TWENTY-FOUR INCHES OF AN IMPERMEABLE SURFACE UNLESS THE ADJACENT IMPERMEABLE SURFACES ARE DESIGNED AND CONSTRUCTED TO CAUSE WATER TO DRAIN ENTIRELY INTO A LANDSCAPED AREA. 37. THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A COPY OF THE PROJECT'S SPECIFICATION MANUAL PRIOR TO BIDDING THIS PROJECT. THE PROJECT SPECIFICATIONS ARE TO BE MADE A PART OF THESE PLANS. THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR IMPLEMENTING ALL WORK AS SPECIFIED WITHIN THE LANDSCAPE SPECIFICATION MANUAL AND AS DEFINED WITHIN THESE LANDSCAPE DRAWINGS. 38. ALL WORK CALLED FOR ON THESE DRAWINGS BY NOTES OR DETAILS SHALL BE FURNISHED AND INSTALLED WHETHER OR NOT SPECIFICALLY MENTIONED IN THE SPECIFICATIONS. WHEN AN ITEMS IS SHOWN ON THE PLANS, BUT NOT ADDRESSED WITHIN THE SPECIFICATIONS OR VISE VERSA, IT SHALL BE DEEMED TO BE SHOWN ON BOTH. THE LANDSCAPE ARCHITECT SHALL HAVE FINAL AUTHORITY FOR CLARIFICATION IN ALL INSTANCES. SUBSURFACE IRRIGATION INSTALLATION NOTES: 1. ASSEMBLE AND INSTALL FILTER, REMOTE CONTROL VALVE AND PRESSURE REGULATING VALVE ASSEMBLIES ACCORDING TO DETAILS. 2. ASSEMBLE AND INSTALL SUPPLY HEADERS ACCORDING TO DETAIL. TAPE OR PLUG OPEN CONNECTIONS TO PREVENT DEBRIS CONTAMINATION. 3. ASSEMBLE AND INSTALL EXHAUST HEADERS IN ACCORDANCE WITH DETAIL. TAPE OR PLUG OPEN CONNECTIONS TO PREVENT DEBRIS CONTAMINATION. 4. INSTALL DRIP LATERALS. TAPE OR PLUG OPEN ENDS TO PREVENT DEBRIS CONTAMINATION 5. THOROUGHLY FLUSH DRIPLINE LATERALS AND CONNECT TO EXHAUST HEADERS OR INTERCONNECTING LATERALS WHILE FLUSHING. 6. THOROUGHLY FLUSH EXHAUST HEADERS AND INSTALL LINE FLUSHING VALVES ACCORDING TO DETAILS. 7. THOROUGH FLUSHING OF EACH INSTALLATION SEGMENT IS NECESSARY TO ENSURE THAT NO DEBRIS CONTAMINATION OCCURS. 8. SEE IRRIGATION NOTES, LEGENDS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION REGARDING SUBSURFACE IRRIGATION PRODUCTS AND INSTALLATION. 9. BURY DRIPLINE 3" BELOW GRADE AND STAKE AT 36" O.C. IN ORDER TO SECURE LINE TO GROUND AND MAINTAIN PRECISE LINE LAYOUT SPACING. 10. ALL SUBSURFACE LINE FITTINGS USED FOR THIS PROJECT WILL BE PER THE SPECIFIC SUBSURFACE DRIPPER LINE MANUFACTURER'S SPECIFICATIONS. NO THIRD PARTY EQUIPMENT IS TO BE INCORPORATED INTO THIS SYSTEM. I 1 I ' I I - /1\ v",:.os c....::" ~ r --:, ,'\ • ".>, 'Pi "' ' 3 * !a * --"' 2725 Jefferson street, suite 15b carlsbad, ca 92008 phone: 760.720,ll337 d'1,"-..." '"" ?~'l" 'Ill, OF cp,\.lfrj?' DATE INITIAL fmi:: 760.720.9505 REVISION DESCRIPTION Elcpiration Date: 4/30/23 DESIGNER OF WORK APPROVED FOR /RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUILT" APPROVED RCE EXP. DATE f""f\,t" ~~·1=Ru -~T~o-,~ -l, Lri\ ~,,,,) I ., · C J · , 1,, SET REVIEWED BY: INSPECTOR DATE I SH~ET I CITY OF CARLSBAD ~ PLANNING DIVISION 2 LANDSCAPE IMPROVEMENT PLANS FOR: HEMLOCK COAST HOMES 320 HEMLOCK AVENUE, CARLSBAD, CA IRRIGATION NOTES I APPROVED:::::;a:: 42.~. I --,/44/2.1 PLANNING OWN BY: JSS PROJECT NO. DRAWING NO. DATE INITIAL DATE INITLI\L CHKD BY: JSS OTHER APPROVAL CITY APPROVAL RVWDBY: LPC2021-0012, PUD2020-0001 530-5L PLOT DATE: 7/8/21 2021-03-30_Hemlock Homes TIUe Block. vwx PROPERTY LINE 1 TRUNK 6' BTH C, 0 ' c<i .o 2TRUNKS 10' BTH PROPERTY LINE s 6 -+---,r----1-fll P PROPERTY LINE ,--+-=-,---' / , -s------[_ _.if)_ ----_____ ----CJ)--~ -7 ___ -, I __ __ __ __ __ r·: w w ~ w w ~ G ---+ G ··· --G ·· ------G s I I, --\ I I I I I I M z _ _,__ G - _I PROPOSED 2'-0" WIDE PEDESTRIAN ACCESS EASEMENT TO THE CITY OF CARLSBAD DIAL TOLL FREE 1 -800 -422 -4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA >. CALTRANS SIGHT DISTANCE I VIEW CORRIDOR FOR ALL LINES OF SIGHT LIMITS. TREES THAT FALL WITHIN THE LIMITS OF A VEHICULAR SIGHT LINE, IS REQUIRED TO HAVE THE TREE CANOPY HEIGHT MAINTAINED AT A MINIMUM HEIGHT OF 6'-0" ABOVE THE ADJACENT CURB, F RIVER ROCK COBBLE GROUNDCOVER 12 TYPICAL G ALUMINUM PATHWAY EDGING 10 TYPICAL H DECOMPOSED GRANITE PAVING 10 TYPICAL B ROOT BARRIER 12 TYPICAL *SEE SHEET 9 FOR PLANTING LEGEND APPROVED FOR /RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. """® ~ ~ = = 2725 Jeff era on street, suite 15b cerlebad, ca 92008 phone: 760,720.9337 fa,c: 7B0.720,9505 ExrAralion Date: "AS BUILT" 10 0 5 10 20 40 RCE---EXP,----DATE ~ I I i I REVIEWED BY: SCALE: 1"=10'-0" FEET INSPECTOR DATE t---t----t-------------+---+----+--+------11 SH~ET I CITY OF CARLSBAD ~ ;:::::::::::;::::~:::::::::::::::::::::::::;::;P::LA::NN::;IN::;G:::::D=IVl::S::10::N=====...'.:~==~ LANDSCAPE IMPROVEMENT PLANS FOR: HEMLOCK COAST HOMES 320 HEMLOCK AVENUE, CARLSBAD, CA PLANTING PLAN APPROVED: ,__ __ 1----+-----------------1------1---+----1----1 ::'=P::':LA:::'N::Nl':':NG':::===:;:;;:;;:=::,;--~=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-,::::;-;::====~ DWN BY: JSS DATE INITIAL REVISION DESCRIPTION DATE INITIAL DATE INITIAL 413Ql23 DESIGNER OF WORK OTHER APPROVAL CITY APPROVAL CHKD BY: JSS RVWDBY: PROJECT NO. LPC2021-D012, PUD2020-0001 PLOT DATE: 718/21 DRAWING NO. 530-SL 2021-03-30_Hemlock Hames -nue Black.vwx PLANTING LEGEND SYMBOL BOTANICAL NAME TREES ARCHONTOPHOENIX CUNNINGHAM/ANA HOWEA FORSTER/ANA X --------,SPATHODEA CAMPANULATA I SHRUBS 0 BOUGAINVILLEA 'DO-LA-LA' €)---DRYOPTERIS ERYTHROSQRA 0 HAMEL/A PATENS 'COMPACTA' @ LANTANA 'NEW GOLD' ~-NANDINA DOMESTJCA 'GULF STREAM' ~ NAND/NA DOMESTICS 'HARBOR DWARF' FLOWERING PERENNIALS @---1AECHMEA GAMESEPALA 0 -----ICL/VIA M/NIATA 0 ---ICOREOPSIS 'SUNRAY' -------aHAEMANTHUS ALB/FLOSS 0-""KNIPHOFIA 'PINEAPPLE POPSICLE' . ·.·.·.·.·.•.•,•,•,•,•,•,•,•,•,• €13 -----lLfMONJUM PEREZ/I ' . . . . . ' . . . . . . .. ' . . . . . . ' . ' " . . ... ' . . . . . . . . . . . . " . ' . . . . . . . . . . . .... . . . . . . . . . . . . . .. :-:-:-:-:-:-:-:-:-: ·:·:·:·:-:-:,___ ____ ____,IMPATIENS WALLER/ANA ' . . . . . . . . . . . . .. . . . . . . . . . . . . . ... . . . . . . . . . . . . . .. . . -. " . . . . . . . .. " . ···············-. . -. --. . . . . . . . " . GRASSES AND GRASS LIKE 0--CAREX 0/VULSA ~----l ~ CHONDROPETALUM TECTORUM SUCCULENTS AND CACTUS @ AEON/UM ARBOREUM 'ATROPURPUREUM' @-------'AEON/UM URB/CUM 'SALAD BOWL' @--BULB/NE NATALENSIS VINES AND ESPALIERS rvtJ£llV1 JASMINUM ANGULARE l'\/U.&l/V'I HARDENBERGIA 'CANOELANDS' MJ()JlJl SOLLYA HETEROPHYLLA GROUND COVERS -OPHJOPOGON PLANISCAPUS 'NIGRESCENS' .. . ".":,·,· TURF .. • -ORIGINAL MARATHON .'.i{/f?t:·:t-'c_:?_:-<:'\\}?~}'.'.}~'.~ i;,,'.• t/;';'; }:;,:\•/;· ... ·•.; ~ -DECOMPOSED GRANITE i:1;:::::J:JIL:iii,I.::i.;;::1i COMMON NAME AFRICAN TULIP TREE BOUGAINVILLEA AUTUMN FERN FIRECRACKER BUSH LANTANA HEAVENLY BAMBOO DWARF HEAVENLY BAMBOO MATCHSTICK PLANT KAFFIR LILY TICKSEED DAPPLED SNOWBUSH YELLOW HOT POKER STATICE BUSY LIZZIE BERKELEY SEDGE SMALL CAPE RUSH ROYAL PINWHEEL SALAD BOWL URBICUM ROOLWORTEL SOUTH AFRICAN JASMINE LILAC VINE AUSTRAILIAN BLUEBELL CREEPER GOLD MOSS BLACK MONDO GRASS MARATHON TURF 4 2 5 12 4 3 6 11 19 3 26 34 4 8 76 3 4 9 8 6 2 REMARKS SEE PLAN FOR TOTAL BTH AND NUMBER OF TRUNKS, SUN GROWN SEE PLAN FOR TOTAL BTH AND NUMBER OF TRUNKS, SUN GROWN 24" BOX STANDARD TRUNK 5 GAL SGAL. 5GAL. 5 GAL. SGAL. 5GAL. 1 GAL. 5GAL. 1 GAL. SGAL. 1 GAL. 5GAL. MIXED PASTEL COLORS, PLANT AT 12" 4" POTS O.C. 1 GAL 5 GAL 5GAL. 5GAL 1 GAL SGAL 5 GAL 5 GAL MOUNT ONTO 4' X 4' REDWOOD TRELLIS MOUNT ONTO 4' X 4' REDWOOD TRELLIS MOUNT ONTO 4' X 4' REDWOOD TRELLIS FROM FLATS PLANT AT 8" O.C. FROM FLATS PLANT AT 8" O.C. SOD AVAIL THRU SOUTHLAND SOD FARMS DETAIL REF. C/10 A/10 D/10 j E/10 E/10 H/10 F/10 WUCOL RATING M M M L M L L L L L L L L L L M L L L L L M L L L M H VL VL ""'i!l!i!l ~ ;:::::J I II ■ -=- 2725 Jafferson street, suite 15b cerlsbed, ca 92008 pl'lone: 760.720.B337 fai<: 760,720,9505 /1\ Nose~ ·~~ ;i ~ "' "" * V Rj;lwal-De~ * \ _Q_"'-~ J u> ~ ,., ./.~ :>;, &-.°"' ~OFCA\.l'r DATE INITIAL Expiralion Dale: 4130123 DESIGNER OF WORK APPROVED FOR /RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUILT" ~.,. .. I --·~·--· /41\PP tr)} (1 '\ 1 ~= D /}'"' , •••• ~"' • ft ,=. ,; -,-, ,. ··• .. ,:fw:'. ·) -.:-,:.;. t..-=• RCE EXP. DATE ((::c»ii~~s~fR[L~CT~ON ~E~T ~i: .• REVIEWED BY: --·-··-·-·-...... ,. •==m; __ DATE INSPECTOR I SH~ET I CITY OF CARLSBAD ~ PLANNING DIVISION 2 LANDSCAPE IMPROVEMENT PLANS FOR: HEMLOCK COAST HOMES i 320 HEMLOCK AVENUE, CARLSBAD, CA I PLANTING LEGEND I I APPROVE~'-''-~~ I 1 /,4/1..,1 PLANNING OWN BY: JSS PROJECT NO. DRAWING NO. REVISION DESCRIPTION DATE INITIAL DATE INITIAL CHKD BY: JSS OTHER APPROVAL CITY APPROVAL RVWDBY: LPC2021-0012, PUD2020-0001 530-SL PLOT DATE: 718121 2021-03-30_Hemlock Homes 77tle Block.vwx ~ 0 0 SET SHRUB CROWN 1" ABOVE FINISH GRADE. 3" MULCH LAYER PER PLANTING NOTES 4" HIGH WATER RETENTION BASIN RAKE OUT AFTER 90 DAYS U.O.N. NOTE PERTAINS TO ON-GRADE PLANTERS ONLY. NOTE: 0 0 0 FINISH GRADE PLANT FERTILIZER TABLETS, PER PLANTING NOTES PLANT ROOTBALL, PREPARE PER PLANTING NOTES. 2X ROOTBALL DIAMETER 0 PREPARED BACKFILL MIX, SEE PLANTING NOTES FOR BACKFILL MIX CONTENTS. BACKFILL MIX SHALL NOT BE INSTALLED ANY DEEPER THAN 12" FROM TOP OF SURROUNDING FINISH GRADE, INSTALL NATIVE SOILS FOR DEPTHS BELOW 12", NOTE PERTAINS TO ON GRADE PLANTERS ONLY. 0 SCARIFY SOIL ALONG SIDES AND BOTTOM OF PLANTING PIT. NOTE PERTAINS TO ON GRADE PLANTERS ONLY. B 1. WliEN PLANTED ON SLOPES, THE FRONT AND REAR OF THE PLANTING PITS SHALL BE GRADED AT A MAXIMUM OF A 1 :1 SLOPE. EROSION CONTROL FABRIC SHALL BE INSTALLED ON THESE SLOPES TO CONTROL EROSION WHILE PLANTS ESTABLISH. ORNAMENTAL TREES & SHRUB PLANTING 1 GAL. THRU 36" BOX LEVEL GRADE NOTTO SCALE NOTES: 1. ALL GROUND COVER IS TO BE PLANTED IN A TRIANGULAR GRID AS SHOWN 2. FOR PLANT ON CENTER SPACING SEE PLANT LEGEND 3. FOR MULCH LAYER SEE PLANTING NOTES ® GROUND COVER PLANTING NOTTO SCALE ~ 0 0 7 TREE TRUNK TO BE EQUIDISTANT FROM 0 PLASTIC ROOT BARRIER: 24-INCH 0 CURB/GUTTER (TYP.) BOTH ENDS OF ROOT BARRIER MIN. DEPTH ADJ. TO SIDEWALK PLASTIC ROOT BARRIER: BACKFILL MIX 24-INCH MIN. DEPTH ADJ. FINISH GRADE TO BE 3" BELOW TOP 0 0 TO CURB OF CURB HEIGHT TO ALLOW FOR MULCH MATERIAL. SIDEWALK (TYP.) 2 SECTION VIEW 0 ROOTBALL 0 NATIVE SOIL 4 3 4 • • 10'-0" PLAN VIEW NOTES: 1. ROOT BARRIER SHALL BE INSTALLED INA LINEAR FASHION PARALLEL TO EDGE OF HARDSCAPE (DON'T ENCIRCLE ROOTBALL) • 20 FEET MIN. LENGTH EACH TREE. 2. TOP OF ROOT CONTROL BARRIER SHALL BE 1 INCH ABOVE FINISH GRADE (MIN.). 3. ROOT BARRIER SHALL BE INSTALLED WITH RAISED ROOT DIVERTERS FACING TOWARD THE TREE ROOTBALL. 0 ROOT CONTROL BARRIER NOTTO SCALE DECORATIVE COBBLE, SEE NOTES BELOW DEWITT PR0-5 WEED BARRIER, INSTALL PER MANUFACTURER'S SPECIFICATIONS. ONLY INSTALL THE WEED BARRIER WHEN COBBLE IS INSTALLED IN AN ON-GRADE CONDITION. ~---,1 NATIVE SOIL 2 '-----13 NOTES: 1. DECORATIVE COBBLE TO BE BEACH PEBBLE MIX, 3"-5" DIA. WITHIN PLANTER BEDS AND 112"·1" IN BETWEEN CONCRETE PATIO SLABS WHERE INDICATED, AVAILABLE THRU KRC ROCK, PH. (760) 744-1036. 2. DEPTH OF ROCK TO BE DEEP ENOUGH TO COVER 100% OF THE WEED BARRIER FABRIC. (NO FABRIC SHOULD BE VISIBLE) 0 COBBLE GROUND COVER NOTTO SCALE OJ TREE CANOPY 0 TREE TRUNK (2) CINCH TIES, TACK TO STAKE WITH 0 1 X4 DOUG. FIR BRACE. TACK TD LODGEPOLE 0 STAKES WITH GALV. NAILS GALV. NAILS TO PREVENT SLIPPING 0 (2) 2" DIA, X 8' LONG UNTREATED LODGEPOLE 0 TREE ROOT BALL (DO NOT PENETRATE WITli PINE STAKES FOR 5 GAL. TREES, STAKE) OR (2) 2" DIA. X 10' LONG UNTREATED LODGEPOLE 0 ARBOR GUARD MODEL# AG8-4. USE PINE TAKES FOR 15 GAL-3~' BOX TREES, SET IN TURF AREAS ONLY. STAKES OUTSIDE ROOTBALL ANGLE TOP OF ~ FACE OF BUILDING, POST, COLUMN, OR WALL STAKE AWAY FROM BRANCH STRUCTURE. 0 SPREAD ON WALLAND SECURE 2 0 REMOVE NURSERY STAKE 3 0 MULCH LAYER (SEE PLANTING NOTES FOR DEPTH) PREVAILING WIND 0 SET ROOTBALL TIGHTTO FOOTING. "' SECTION VIEW PLANVIEW NOTES: 1. INSTALL TREE TIES AND STAKES ONLY TO PROPER LEVEL TO HOLD TREE UPRIGHT. PROPER HEIGHT IS 6" ABOVE POINT WHERE THE TREE WILL SNAP TO AN UPRIGHT POSITION BY ITSELF IFTOP IS PULLED TO ONE SIDE AS IFWIND LOADED AND THEN RELEASED. DO NOT TOP TREES IN ORDER TO REDUCE SIZE OR WEIGHT OF TREE CROWN, CONTACT LANDSCAPE ARCHITECT PRIOR TO ANY PRUNING OF TREES. 0 0 0 0 ~ REMOVE ANY BIULDING MATERIALS THAT MAY BE UNEARTHED WHEN DIGGING OUT PLANTING PIT. 6" HIGH WATER RETENTION BASIN ON SLOPE, 3'-4" OTHERWISE FINISH GRADE PLANT FERTILIZER TABLETS, PER PLANTING NOTES. PREPARED BACKFILL MIX,SEE PLANTING NOTES FOR BACKFILL MIX. SCARIFY SOIL ALONG SIDES AND BOTTOM OF PLANTING PIT. TREE STAKING 5 GAL. THRU 36" BOX NOTTO SCALE 0 VINE I ESPALIER PLANTING NOTTO SCALE CONNECTOR STAKES ~------i111 ISOMETRIC VIEW NOTES: ~~~~~OJ[J~~tSTRIP TOP OF EDGING TO BE MAXIMUM OF 1/4" 16.4 MM) ABOVE SURFACE MATERIAL COMPACT GRADES ADJACENT TO EDGING TO AVOID SETTLING [~l~~~) DECOMPOSED HORIZONTAL BASE FOR EXTRA-~ RIGIDITY COMPACTED SUBGRADE TO 95% 12" 1305 MMl ALUMINUM STAKES TO LOCK INTO PERFORMED LOOPS ON THE EDGING 1. INSTALL PER MANUFACTURERS "INSTALLATION GUIDELINES'. 2. 8'-0' (2.44 M) SECTIONS TO INCLUDE 13) 12" j305 MM) ALUMINUM STAKES. 3. 16'-0" (4.88 M) SECTIONS TO INCLUDE (8) 12 (305 MM) ALUMINUM STAKES. 4. CORNERS: NOTCH BASE ONLY AND FORM A CONTINUOUS CORNER. 5. PERMALOC PERMASTRIP AS MANUFACTURED BY PERMALOC CORPORATION. 6. DO NOT SCALE DRAWING. 7. ALUMINUM EDGING TO BE 3/16" X 3112", FINISH TO BE MILL FINISH-NATURALALUMINUM ALUMINUM EDGING AT DECOMPOSED GRANITE PAVING NOTTO SCALE [Ci)@ SIDE VIEW ~ DECOMPOSED GRANITE TO BE PLACED TO A DEPTli OF 3". COLOR TO BE PEWTER GREY, STABILIZED, AVAIL. THRU KRC ROCK, PH. 760-744-1036. INSTALL IN MULTIPLE 1 1/2" LIFTS, SOAK THROUGHLY WITH WATER, COMPACT WITH A HEAVY WATER ROLLER, DR VIBRATING PLATE COMPACTOR. AFTER SOAKING WITH WATER, IT'S BEST TO LET THE MATERIAL SIT FOR 8 HOURS PRIOR TO COMPACTING. 0 NATIVE SOIL COMPACTED TO 95% DECOMPOSED GRANITE GROUND COVER NOTTO SCALE APPROVED FOR /RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUILT" RCE---EXP.----DATE REVIEWED BY: INSPECTOR DATE ~ lliiii' = II,\ ~ CITY OF CARLSBAD ~ 1----+----11------------------+---+---t------ir---t ~ PLANNING DIVISION ~ - plarin1ri11 ■· ■ ■ 2725 Jsffersori street, suite 15tJ carlsbad, ca 92008 phone: 760,720.9337 falC 780,720,95□5 1:)(1 iration Date: 4130/23 :==:::::...::================:.-=====; LANDSCAPE IMPROVEMENT PLANS FOR: HEMLOCK COAST HOMES 320 HEMLOCK AVENUE, CARLSBAD, CA PLANTING DETAILS 1-----t----t----------+----+----+------t------t IA _PPR-OVEDLJL./~~~i~0~·~--~- .PLANNING ¥ DATE INITIAL REVISION DESCRIPTION DATE INITIAL DATE INITIAL DESIGNER OF WORK OTHER APPROVAL CITY APPROVAL DWN BY: CHKDBY: RVWDBY: JSS JSS PROJECT NO. LPC2021-0012, PUD2020-0001 PLOT DATE: 7/8/21 DRAWING NO. 530-5L 2021-03-30_Hemlock Homes Title Block.vwx PLANTING NOTES 1. LANDSCAPE CONTRACTOR SHALL RECEIVE THE SITE WITHIN PLUS OR MINUS . 10 FEET OF FINISH GRADE. RAISED PLANTERS ARE EXEMPT FROM THIS STANDARD. 2. THE PLANTING PLANS ARE DIAGRAMMATIC. MINOR ADJUSTMENTS IN PLANT LOCATIONS MAY BE MADE AT THE DISCRETION OF THE LANDSCAPE ARCHITECT. 3. THE LANDSCAPE CONTRACTOR WILL COORDINATE HIS WORK WITH THE OTHER TRADES AND MAINTAIN SITE DRAINAGE DURING CONSTRUCTION. 4. PLANT QUANTITIESANDAREAS SHOWN ON LEGENDS ARE FOR CONTRACTOR'S CONVENIENCE IN ESTIMATING ONLY. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING PLANT MATERIALS AS GRAPHICALLY REPRESENTED WITHIN THESE DRAWINGS. 5. LANDSCAPE ARCHITECT, OWNER, OR OWNER'S REPRESENTATIVE SHALL APPROVE FINAL PLACEMENT OF ALL TREES, SHRUBS, AND VINES PRIOR TO PLANTING. 6. TREE AND SHRUB PITS 15 GALLONS OR SMALLER SHALL BE TWO TIMES ROOTBALL DIAMETER WIDE AND EQUAL WITH ROOTBALL DEPTH. TREE AND SHRUB PITS FOR 20" BOX AND LARGER SHALL BE 1-1/2 TIMES ROOTBALL DIAMETER WIDE AND EQUAL WITH ROOTBALL DEPTH. 7. TREE STAKING SHALL BE DONE PER DETAIL C/10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE TREE'S STABILITY DURING THE LENGTH OF THE GUARANTEE PERIOD. ALL STAKING MATERIALS SHALL BE REMOVED AT THE END OF THE 1-YEAR TREE GUARANTEE PERIOD. 8. ORGANIC AMENDMENT FOR THIS PROJECT SHALL BE FULLY COMPOSTED HUMUS, OR APPROVED EQUAL. 9. PLANTING BACKFILL MIX FOR ALL CONTAINER PLANTS. ON SITE SOIL FULLY COMPOSTED HUMUS GROW-POWER PLUS FERTILIZER AGRICULTURAL GYPSUM PREMIUM GREEN IRON BY GROW-POWER SCU. YDS. 1 CU. YDS. 6 LBS./C.Y. 4 LBS.ICY. 1 LB.ICY. NOTE: AMENDED BACKFILL MIX WITH NO MORE THAN 20% BY VOLUME ORGANIC MATTER SHALL BE PLACED IN UPPER 12" OF BACKFILL ONLY. SOIL BELOW THIS DEPTH SHOULD NOT CONTAIN ANY ADDED ORGANIC MATTER BECAUSE OF DISEASE AND OR ANAEROBIC SOIL CONDITIONS DEVELOPING 10. ALL PLANTS 1-GALLON SIZE OR LARGER SHALL RECEIVE AGRIFORM 21-GRAM 20-10-5 FERTILIZER TABLETS AT THE FOLLOWING RATES: 1-GALLON: ONE 5-GALLON: TWO 15-GALLON: THREE BOXED TREES: ONE PER 112" CALIPER PLACE TABLET 6-8" DEEP AND IN CONTACT WITH ROOTBALL. 11. ALL PLANTS INSTALLED FROM FLATS SHALL RECEIVE ONEAGRIFORM 5-GRAM 20-10-5 TABLET EACH, MIXED WITH A HANDFUL AMENDED BACKFILL. 12. ALL PLANTS EXCEPT BOUGAINVILLEA PLANTED FROM CONTAINERS SHALL HAVE THEIR ROOTBALLS SCORED WITH A SHARP TOOL TO A DEPTH OF 1' IN THREE LONGITUDINAL INCISIONS AT LOCATIONS SPACED AROUND THE ROOTBALL BEFORE PLACING PLANT IN PLANTING HOLE. BOUGAINVILLEAS SHALL BE PLANTED WITH INTACT ROOTBALLS, BROKEN ROOTBALLS WILL BE NOT BE ACCEPTED. 13. ALL NURSERY TYING MATERIALS AND MARKING TAPES SHALL BE REMOVED AT THE TIME OF PLANTING. 14. STAKES SHALL BE REMOVED FROM VINES, THEN TRAINED TO WALL, POST, OR COLUMN PER PLANTING DETAIL. 15. CONTRACTOR SHALL VERIFY ALL PLANTING AREA SIZES AND THE EXTENT OF THEIR PLANTING. IF ANY DISCREPANCIES OCCUR, PLEASE BRING THESE TO THE ATTENTION OF THE OWNER AT THE TIME YOUR BID IS SUBMITTED. 16. ALL BOXED TREE PITS ARE TO BE EVALUATED FOR DRAINAGE. THE TEST CONSISTS OF FILLING THE PITS WITH WATER TO A DEPTH OF 12' TWO TIMES OVER A4B HOUR PERIOD. IF THE WATER LEVEL HAS NOT MOVED DOWN AT LEAST 114" PER HOUR OR MORE, THE PLANTING PIT SHOULD BE CONSIDERED TO HAVE POOR DRAINAGE CHARACTERISTICS. THE CONTRACTOR IS TO CONTACT THE LANDSCAPE ARCHITECT AND A DRAINAGE PROGRAM WILL BE DEVISED FOR THE SITE'S SPECIFIC CONDITIONS. 17. THE FOLLOWING SHALL BE APPLIED FOR 1,000 SQ. FT. OF PLANTING AREA AND MECHANICALLY TILLED INTO THE SOIL TOA DEPTH OF 6" TO 8" FOR ALL LANDSCAPED AREAS WITH A SLOPE OF 31 OR LESS. THE CONTRACTOR SHALL USE THE FOLLOWING AMENDMENT SCHEDULE FOR BIDDING PURPOSES ONLY. A SOIL TEST SHALL BE MADE AS PART OF THIS CONTRACT, AND RECOMMENDED AMENDMENTS SHALL BE USED FOR ACTUAL INSTALLATION. AFTER ROUGH GRADING, SOIL SAMPLES SHALL BE TAKEN FROM SEVERAL REPRESENTATIVE LOCATIONS THROUGHOUT THE SITE IN ORDER TO PROVIDE A THOROUGH EXHIBIT FOR THE LABORATORY TO TEST AND EVALUATE. SOIL TESTING SHALL BE PERFORMED BY A SOIL TESTING LABORATORY (PRE-APPROVED BY THE CITY). THE TEST SHALL INDICATE BUT NOT BE LIMITED TO THE FOLLOWING: ORGANIC CONTENT, NPK, PH, EC, SOIL TEXTURE (SILT,CLAY,SAND) AND RECOMMENDATIONS FOR AMENDMENTS, LEACHING, AND MAINTENANCE FERTILIZERS. THE RESULTS AND RECOMMENDATIONS OF THE SOIL TESTING LABORATORY SHALL BE SUBMITTED TO AND APPROVED BY THE CITY. THE APPROVED RECOMMENDATIONS FOR AMENDMENTS AND BACKFILL SHALL BE INCORPORATED INTO THE LANDSCAPE PLANS PRIOR TO CONSTRUCTION AND SHALL BECOME PART OF THE APPROVED PLANS. AGRICULTURAL GYPSUM AGRIFORM 18-18-6 FERTILIZER PREMIUM GREEN IRON BY GROW POWER FULLY COMPOSTED HUMUS 100 LBS. 25 LBS. 10 LBS. 5 CUBIC YARDS A FOR LANDSCAPE INSTALLATIONS, COMPOST AT A RATE OFA MINIMUM OF FOUR (4) CUBIC YARDS PER 1,000 SQUARE FEET OF PERMEABLE AREA SHALL BE INCORPORATED TO A DEPTH OF SIX INCHES INTO THE SOIL. SOILS WITH GREATER THAN 6% ORGANIC MATTER IN THE TOP 6 INCHES OF SOIL ARE EXEMPT FROM ADDING CON.POST AND TILLING. 8. PRIOR TO PLANTING OF ANY MATERIALS, COMPACTED SOILS SHALL BE TRANSFORMED TO A FIEABLE CONDITION. ON ENGINEERED SLOPES, ONLY AMENDED PLANTING HOLES NEED MEET THE REQUIREMENT OF THIS SECTION. C. THE APPLICATION OF ORGANIC MULCH MATERIALS MADE FROM RECYCLED OR POST-CONSUMER MATERIALS SHALL TAKE PRECEDENCE OVER INORGANIC MATERIALS UNLESS RECYCLED OR POST-CONSUMER ORGANIC PRODUCTS ARE NOT LOCALLY AVAILABLE. 18. NO IRON SULFATE SHALL COME IN CONTACT WITH ANY MASONRY SURFACE. 19. SLOPE ALL PLANTING AREAS AWAY FROM BUILDING AT 2% MINIMUM FOR 5 FEET MINIMUM, WHERE APPLICABLE. ALL GRADING ON SITE SHALL HAVE POSITIVE SURFACE DRAINAGE (2% MINIMUM GRADE IN PLANTING AREAS) AWAY FROM STRUCTURES AND TERMINATING IN AN APPROVED DRAINAGE SYSTEM. 20. LAWN AREAS SHALL HAVE A MAXIMUM SLOPE INCLINE OF 4:1, GROUND COVER TO BE 2:1 UNLESS OTHERWISE NOTED. 21. CONTRACTOR SHALL VERIFY LOCATION OF ALL UNDERGROUND UTILITIES AND SERVICES PRIOR TO ANY DIGGING. CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR ALL DAMAGE CAUSED BY FAILURE TO DO SO. 22. ANY SUBSTITUTIONS MUST BE APPROVED IN WRITING BY LANDSCAPE ARCHITECT. 23. GROUND COVER IS NOT SHOWN UNDER SHRUBS FOR GRAPHIC CLARITY. GROUND COVERS ARE TO BE PLANTED WITHIN ALL SHRUB DRIP LINES UNLESS OTHERWISE NOTED. 24. PRIDR TO PLANTING, THE IRRIGATION SYSTEM SHALL BE FULLY OPERATIONAL. ALL PLANTING AREAS SHALL BE THOROUGHLY WATERED IMMEDIATELY AFTER PLANTING AND APPLICATION OF FERTILIZER. 25. LANDSCAPE CONTRACTOR SHALL REMOVE ALL EXISTING VEGETATION, TRASH, CLIPPINGS, ROCK, AND OTHER DEBRIS FROM THE SITE AND DISPOSE OF IT AT AN APPROVED DISPOSAL SITE. ADDITIONALLY, THE CONTRACTOR SHALL RAKE AND FINE GRADE ALL AREAS TO BE PLANTED PRIOR TO THE COMMENCEMENT OF PLANTING OPERATIONS. 26. ALL TREES PLANTED WITHIN 5' OF FLATWORKAREAARE TO HAVE A DEEP ROOT BARRIER INSTALLED, SEE DRAWINGS FOR LOCATIONS. BARRIER TO BE BY DEEP ROOT CORPORATION, MODEL UB-24-2, INSTALL PER MANUFACTURER'S SPECIFICATIONS. SEE DETAIL B/10 27. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY REPAIRS MADE NECESSARY THROUGH THE ACTIONS OR NEGLIGENCE OF HIS OR HER CREW. 28. ALL PLANTED AREAS ARE TO HAVE A 3" LAYER OF GORILLA HAIR MULCH (DERIVED FROM RECYCLED REDWOOD) FOR ALL PLANTER BEDS WITH TREES AND SHRUBS, 1" DEPTH FOR AREAS PLANTED WITH GROUND COVER. ONLY AREAS HAVING A 2:1 OR GREATER SLOPE CONDITION AND AREAS INDICATED AS BEING LAWN, DECOMPOSED GRANITE GROUND COVER AND ROCK COBBLE GROUND COVER ARE EXEMPT FROM THIS MULCHING PROGRAM. DO NOT MOUND MULCH DIRECTLY AROUND PLANT TRUNK, LEAVE AN AREA OF APPROXIMATELY 3" BARE AROUND BASE OF ALL TREES AND SHRUBS. THE CONTRACTOR IS TO SUBMIT A SAMPLE OF THE MULCH MATERIAL FOR APPROVAL BY THE OWNER OR LANDSCAPE ARCHITECT IF HE IS RETAINED TO PROVIDE CONSTRUCTION ADMINISTRATION SERVICES. 29. IF IMPORTED SOIL IS REQUIRED TO BUILD THE LANDSCAPE MOUNDS, FIRST SPREAD A 6" LAYER OF TOPSOILATOP THE EXISTING GRADE THE MOUND ISTO BE PLACED UPON AND TILLINTO THE EXISTING SITE SOIL. AFTER THE TWO SOILS HAVE BEEN MIXED THOROUGHLY, YOU MAY THEN CONTINUE BUILDING THE MOUNDS TO THE SPECIFIED HEIGHTS AND FORM. SEE SPECIFICATIONS FOR IMPORTED SOILS, SECTION 02900, 2.5. 30. GUARANTEE: ALL TREES FOR ONE YEAR, SHRUBS FOR NINETY DAYS, AND GROUND COVERS AND LAWN FOR THIRTY DAYS. 31. THE LANDSCAPE CONTRACTOR SHALL MAINTAIN ALL GENERAL PLANTINGS FORA PERIOD OF 30 DAYS. 32. THE MAINTENANCE PERIOD SHALL INCLUDE THE FOLLOWING SCOPE OF WORK. A REQUIRED WATERING TO MAINTAIN HEALTHY PLANTS. B. REMOVAL OF WEEDS FROM LAWN GROUND COVER AND ANY SHRUB BEDS. C. REPLACEMENT OF ANY DEAD, DYING, OR DAMAGED TREES, SHRUBS, AND GROUND COVER. D. FILLING AND REPLANTING ANY LOW AREAS WHICH RETAINED STANDING WATER THUS CAUSING PLANT DAMAGE OR FAILURE E. ADJUSTING OF SPRINKLER HEAD HEIGHTS AND WATERING PATTERNS TO INSURE HEAD TO HEAD COVERAGE F. FILLING AND RE COMPACTION OF ANY ERODED AREAS. G. WEEKLY REMOVAL OF ALL TRASH, LITTER, CLIPPINGS, AND FOREIGN DEBRIS. H. MOWING AND TRIMMING OF ALL TURF AREAS. TURF IS NOT TO EXCEED 3" IN HEIGHT BEFORE MOWING OPERATIONS. COLLECT GRASS CLIPPINGS DURING MOWING OPERATIONS AND REMOVE FROM SITE. I. AT THIRTY DAYS AFTER PLANTING, ALL PLANTED AREAS WITH (OVERHEAD IRRIGATION) IS TO BE FERTILIZED WITH 20 LBS OF GROW POWER 5-3-1 OR EQUAL PER 1000 SQ. FT. IF (DRIP IRRIGATED) APPLY MIRACLE GROW PER 1000 SQ, FT. OF AREA PER MANUFACTURERS SPECIFICATIONS. 33. PRIOR TO THE END OF THE MAINTENANCE PERIOD, THE LANDSCAPE CONTRACTOR SHALL CONTACT THE OWNER TO ARRANGE A FINAL WALK THROUGH. OWNER MUST ACCEPT ALL MAINTAINED AREAS IN WRITING BEFORE THE MAINTENANCE PERIOD CAN BE CONSIDERED COMPLETE. 34. ALL BOXED TREES AND FIELD GROWN TREES SHALL BE APPROVED BY THE OWNER OR LANDSCAPE ARCHITECT PRIOR TO DELIVERY TO THE PROJECT SITE. 35. ALL PLANT MATERIAL SHALL BE HEALTHY, VIGOROUS, AND FREE OF PESTS AND DISEASE. 36. ALL TREES SHALL HAVE A STRAIGHT TRUNK AND FULL HEAD AND MEET ALL REQUIREMENTS SPECIFIED. 37. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL AVOID DAMAGE TO ALL UTILITIES DURING THE COURSE OF THE WORK. LOCATIONS OF EXISTING BURIED UTILITY LINES SHOWN ON THE PLANS ARE BASED UPON BEST AVAILABLE INFORMATION AND ARE TO BE CONSIDERED APPROXIMATE. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR (1) TO VERIFY THE LOCATIONS OF UTILITY LINES ADJACENT TO THE WORK AREA, (2) TO PROECT ALL UTILITY LINES DURING THE CONSTRUCTION PERIOD, AND (3) TO REPAIR ANY AND ALL DAMAGE TO UTILITIES, STRUCTURES, SITE APPURTENANCES, ETC., WHICH MAY OCCUR ASA RESULT OF THE CONSTRUCTION. 38. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL PLANT QUANITIES SHOWN ON THESE PLANS BEFORE PRICING THE WORK. 39. CONTRACTOR SHALL BE RESPONSIBLE FOR DELIVERY SCHEDULE AND PROTECTION BETWEEN DELIVERY AND PLANTING PER SPECIFICATIONS TO MAINTAIN HEALTHY PLANT CONDITIONS. 40. ANY PLANT MATERIAL WHICH IS DISEASED, DISTRESSED, DEAD, OR REJECTED (PRIOR TO SUBSTANTIAL COMPLETION) SHALL BE PROMPTLY REMOVED FROM THE SITE AND REPLACED WITH MATERIAL OF THE SAME SPECIES, QUANTITY, AND SIZE AND MEETING ALL PLANT LIST SPECIFICATIONS. 41. STANDARDS SET FORTH IN "AMERICAN STANDARD FOR NURSERY STOCK' REPRESENT GUIDELINE SPECIFICIATIONS ONLY AND SHALL CONSTITUTE MINIUM QUALITY REQUIREMENTS FOR ALL PLANT MATERIALS SPECIFIED TO BE USED ON THIS PROJECT. 42. THE LANDSCAPE CONTRACTOR IS TO MAKE A PART OF HIS CONTRACTUAL SERVICES AGREEMENT FOR THIS PROJECT THE PREPARATION OF AN IRRIGATION SCHEDULE THAT WILL PROVIDE A YEARLY WATER CONSUMPTION USAGE LESS THAN THE MAWA ESTIMATE PREPARED BY THE LANDSCAPE ARCHITECT, A LANDSCAPE MAINTENACE SCHEDULE FOR THE ENTIRE YEAR, A WATER AUDIT AND A SOILS REPORT AS DEFINED WITHIN THESE PLANTING NOTES AND PER THE STANDARDS DEFINED WITHIN THE CITY OF CARLSBAD'S 2016 LANDSCAPE MANUAL THE LANDSCAPE CONTRACTOR IS TO PROVIDE THIS DOCUMENTATION TO CITY STAFF AS A PART OF THE CERTIFICATION OF COMPLETION PROCESS. 43. ALL AREAS PLANTED WITH ROOTED GROUND COVERS FROM FLATS, SODANO 2" PLUGS, GRASSES PLANTED FROM 2" LINERS AND ARE IRRIGATED BY DRIPPER TUBING ONLY ARE TO BE HAND WATERED ON A DAILY BASIS IN ORDER TO KEEP THE SOIL SURROUNDING THE PLANT ROOTS ADEQUATELY MOIST UNTIL THE PLANT ROOTS HAVE HAD ENOUGH TIME TO MATURE. THIS PROGRAM SHOULD TAKE PLACE FOR A PERIOD OF THIRTY (30) DAYS, ONCE A DAY MINIMUM AND POSSIBLY MORE DEPENDING ON WEATHER AND SOIL CONDITIONS, AT THIRTY (30) DAYS, THE CONTRACTOR IS TO ASSESS THE MATURITY OF THE PLANT'S ROOT STRUCTURE AND DETERMINE IF THEY CAN MAKE CONTACT WITH THE WATERING ZONE OFFERED BY THE DRIPPER TUBINGIRRIGATION SYSTEM. SHOULD THEN DETERMINED IF MORE TIME IS NECESSARY FOR THE ROOTS TO REACH THE DRIPPERLINE WET ZONE. THE CONTRACTOR IS TO CONTINUE WATERING THESE PLANTS UNTIL IT CAN BE DETERMINED THAT THE PLANTS CAN SURVIVE WITHOUT ADDITIONAL WATERING BEYOND WHAT IS PROVIDED BY THE DRIP IRRIGATION SYSTEM INSTALLED. 44. THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A COPY OF THE PROJECT'S SPECIFICATION MANUAL PRIOR TO BIDDING THIS PROJECT. THE PROJECT SPECIFICATIONS ARE TO BE MADE A PART OF THESE PLANS. THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR IMPLEMENTING ALL WORK AS SPECIFIED WITHIN THE LANDSCAPE SPECIFICATION MANUAL AND AS DEFINED WITHIN THESE LANDSCAPE DRAWINGS. 45. ALL WORK CALLED FOR ON THESE DRAWINGS BY NOTES OR DETAILS SHALL BE FURNISHED AND INSTALLED WHETHER OR NOT SPECIFICALLY MENTIONED IN THE SPECIFICATIONS. WHEN AN ITEMS IS SHOWN ON THE PLANS, BUT NOT ADDRESSED WITHIN THE SPECIFICATIONS OR VISE VERSA, IT SHALL BE DEEMED TO BE SHOWN ON BOTH. THE LANDSCAPE ARCHITECT SHALL HAVE FINAL AUTHORITY FOR CLARIFICATION IN ALL INSTANCES. 46. SLOPES 6:1 OR STEEPER REQUIRING EROSION CONTROL MEASURES AS SPECIFIED HEREIN SHALL BE TREATED WITH ONE OR MORE OF THE FOLLOWING PLANTING STANDARDS: a. STANDARD 1 -COVER CROP/REINFORCED STRAW MATTING: COVER CROP SHALL BE A SEED MIX TYPICALLY MADE UP OF QUICK GERMINATING AND FAST COVERING GRASSES, CLOVERS, AND/OR WILD FLOWERS. SUBMIT THE SPECIFIC SEED MIX FOR CITY APPROVAL PRIOR TO APPLICATION. THE COVER CROP SHALL BE APPLIED AT A RATE AND MANNER SUFFICIENT TO PROVIDE 90% COVERAGE WITHIN THIRTY (30) DAYS. TYPE OF REINFORCED STRAW MATTING SHALL BE APPROVED BY THE CITY AND STAKED TO THE SLOPE AS RECOMMENDED BY THE MANUFACTURER. REINFORCED STRAW MATTING SHALL BE REQUIRED WHEN PLANTING OCCURS BETWEEN AUGUST 15ANDAPRIL 15. THE COVER CROP AND/OR REINFORCED STRAW MAT SHALL BE USED THE REMAINDER OF THE YEAR. b. STANDARD #2 -GROUND COVER ONE HUNDRED (100%) PERCENT OF THE AREA SHALL BE PLANTED WITH A GROUND COVER KNOWN TO HAVE EXCELLENT SOIL BINDING CHARACTERISTICS (PLANTED FROM A MINIMUM SIZE OF FLATTED MATERIAL AND SPACED TO PROVIDE FULL COVERAGE WITHIN ONE YEAR). c. STANDARD #3 -LOW SHRUBS LOW SPREADING WOODY SHRUBS (PLANTED FROM A MINIMUM 1-GALLON SIZE CONTAINER) SHALL COVER A MINIMUM OF SEVENTY (70%) PERCENT OF THE SLOPE FACE (AT MATURE SIZE), d. STANDARD #4 -TREES AND/OR LARGE SHRUBS TREES AND/OR LARGE SHRUBS SHALL BE (PLANTED FROM A MINIMUM OF 1 GALLON CONTAINERS)AT A MINIMUM RATE OF ONE (1) PER TWO HUNDRED (200) SQUARE FEET. SLOPES -6:1 OR STEEPER AND: a. 3' OR LESS IN HEIGHT AND ARE ADJACENT TO PUBLIC WALKS OR STREETS REQUIRE AT MINIMUM STANDARD #1. b. 3' TO 8' IN VERTICAL HEIGHT REQUIRE STANDARD #1 (EROSION CONTROL MATTING SHALL BE INSTALLED IN LIEU OF A COVER CROP). #2AND #3. c. IN EXCESS OF 8' IN VERTICAL HEIGHT REQUIRE STANDARDS #1 (EROSION CONTROL MATTING SHALL BE INSTALLED IN LIEU OF A COVER CROP). #2, #3, AND #4. AREAS GRADED FLATTER THAN 6:1 REQUIRE STANDARD #1 (COVER CROP) WITH TEMPORARY IRRIGATION WHEN THEY HAVE ONE OR MORE OF THE FOLLOWING CONDITIONS: a. SHEET GRADED PADS NOT SCHEDULED FOR IMPROVEMENTS WITHIN 6 MONTHS OF COMPLETION OF ROUGH GRADING. b. A POTENTIAL EROSION PROBLEM AS DETERMINED BY THE CITY c. IDENTIFIED BY THE CITY AS HIGHLY VISIBLE AREAS TO THE PUBLIC OR HAVE SPECIAL CONDITIONS THAT WARRANT IMMEDIATE TREATMENT. WEED ERADICATION NOTES A. PRIOR TO ANY NEW PLANTING OPERATIONS TAKING PLACE WITHIN THE WORK AREA LIMITS OF THIS PROJECT, ALL ANNUAL AND PERENNIAL WEEDS ARE TO ERADICATED. 8, THE APPLICATION OF HERBICIDES USED IN THE PROCESS OF ELIMINATING ALL NOXIOUS WEEDS AND POORLY PERFORMING ORNAMENTAL TURF AREAS WITHIN THE LIMITS OF THIS PROJECT SHALL BE DONE BY A STATE LICENSED APPLICATOR FOR THE SPECIFIC HERBICIDES BEING APPLIED. APPLICATION OF THESE PRODUCTS WILL ADHERE TO ALL CURRENT STATE STANDARDS RELATING TO THE STORAGE AND APPLICATION PROCEDURES. C. THE WEED-ABATEMENT PROGRAM IS NOT TO COMMENCE UNTIL THE ENTIRE IRRIGATION SYSTEM HAS BEEN REPAIRED AND CONFIRMED TO BE REMOTELY OPERABLE AND PERFORMING PER THE INTENT OF THE ORIGINAL IRRIGATION DESIGN LAYOUT AND INSTALLATION STANDARDS. PRIOR TO THE WEED ABATEMENT PROGRAM BEGINNING, ALL PLANTING AREAS WITHIN THE LIMITS OF THIS PROJECT ARE TO BE WATERED FOR A PERIOD OF 30 DAYS TO ENCOURAGE ADDITIONAL PLANT GROWTH. WAIT (2) DAYS AFTER THE WATERING PROGRAM AND THEN PROCEED WITH STEP 'D'. D. REMOVE AND DISPOSE OF ALL EXISTING ANNUAL WEEDS, GRASSES AND ORNAMENTAL TURF WHERE INDICTED. THE TURF AND ANY PERENNIAL WEEDS SHALL BE SPRAYED WITH A SYSTEMIC HERBICIDE AND THEN WAIT FOR A PERIOD OF TIME DEFINED BY THE MANUFACTURER FORA COMPLETE KILL TO TAKE PLACE. TYPICALLY THIS IS BETWEEN 7 AND 14 DAYS DEPENDING ON CURRENT WEATHER CONDITIONS. E. REMOVE ANY REMAINING WEEDS AND TURF AND THEN FERTILIZE ALL PLANTER BEDS AND LAWN AREAS WITH AMMONIUM SULFATE AT A RATE OF 5 LBS.11000 S.F. AND AS NECESSARY TO GERMINATE ALL RESIDUAL WEED SEED OR GRASSES THAT MAY REMAIN. WATER FOR A PERIOD OF 30 DAYS, F. IF ANY PERENNIAL WEEDS OR GRASSES REAPPEAR, APPLY APPROVED SYSTEMIC HERBICIDE OVER THE AFFECTED AREAS. IF ANY ANNUAL WEEDS APPEAR, APPLY APPROVED CONTACT HERBICIDE OVER THESE AFFECTED AREAS. DO NOT IRRIGATE FOR A MINIMUM OF 2 DAYS FOLLOWING THE APPLICATION OF THE SYSTEMIC AND CONTACT HERBICIDES. WATER ALL PLANTER BEDS AND TURF AREAS FOR ANOTHER 30 DAYS. G. REMOVE ALL REMNANTS OF DEAD WEEDS AND TURF AND IF IN THE OPINION OF THE LANDSCAPE CONTRACTOR THEY FEEL A COMPLETE WEED KILL HAS TAKEN PLACE, THEY MAY PROCEED WITH THE SOIL PREPARATION AND FINE GRADING PROCESS REQUIRED PRIOR TO BEGINNING THE PLANTING PHASE. IF THE CONTRACTOR FEELS A THIRD APPLICATION IS REQUIRED, THEN REPEAT PROCESS DEFINED WITHIN NOTE 'F'. APPROVED FOR /RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUILT" RCE---EXP.-----DATE REVIEWED BY: INSPECTOR DATE 11 \ ~ CITY OF CARLSBAD ~ f---+-----l-----------------+---+------11------1---J ~ PLANNING DIVISION ~ n dB~1gn,:.~1.-~i:\:.4:;;~ p·11uinlng· ■ ■ ■ 2725 jllfl'ursan etrael, 11ulle 15b cerlsbad, c:a 9200EI phone: 760.7:20,8337 f8)(: 780.720.9505 Expiration Date: 4/3Q/23 ~L=A::N::::DS::::C::A:'.,P::::E =1M:::P=RO::V::E=M:::EN:::T::::;:PL.A=::N:::S::::FO::::R:::::=====~.'.::== HEMLOCK COAST HOMES 320 HEMLOCK AVENUE, CARLSBAD, CA PLANTING NOTES ! APPROVED~ ,i<iL 7/2,t/2.1 I ~~~~~~;~~~j~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~:~~~~:~~~~~;~~_:::-77 :=P=:LA:=NN=:IN'::'G::::===;;;;;::=;--;:===V==::::::===::;;:::::::::::=::::::::::~· DWN BY: JSS PROJECT NO. DRAWING NO. CHKD BY: JSS RVWD BY: LPC2021-0012, PUD2020-0001 530-5L DATE INITIAL DESIGNER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL PLOT DATE: 7/8121 2021-03-30_Hemlock Homes litle Block.vwx WATER EFFICIENT LANDSCAPE WORKSHEET This worksheet is filled out by the project applicant and it is a required element of the Landscape Documentation Package. HYDROZONE INFORMATION TABLE Please complete the hydrozone table(s) for each hydrozone. Use as many tables as necessary to provide the square footage of landscape area per hydrozone. Controller Hydrozone• Zone # or Valve NIA HWU NIA NIA MWU NIA .,,. ""U "" .,,. I "111 .,,. Total *Hydrozone VL W -Ve,y Low Water Use Plants LW -Low Water Use Plants MW -Moderate Water Use Plants HW -High Water Use Plants Irrigation Plant Method .. Type/Factor*** DRIP DRIP DRIP NO IRRIGATION .. Irrigation Method MS = Micro-spray S = Spray R = Rotor B= Bubbler D= Drip 0 = Other IPFl .80 .50 "" .00 MAXIMUM APPLIED WATER ALLOWANCE Hydrozone % of Total Area (Sq. Ft.) Landscaped Area ooc 20 279 17 93B 56 78 5 1 620 100% ... Plant Factor from WUCOLS Ill or list as water feature as appropriate A landscape project subject to the Water Efficient Landscape Ordinance shall include the MAWA for the plans, including the calculations used to determine the MAWA. A landscape project shall not exceed the MAWA. The MAWA for a landscape project shall be determined by the following equation: MAWA = (ETo)(0.62)[(0.7 x LA)+ (0.3 x SLA)] The abbreviations used in the equation have the following meanings: Maximum Applied Water Allowance in gallons per year. Evapotranspiration in inches per year. Conversion factor to gallons per square foot. ET adjustment factor (ETAF) for plant factors and irrigation efficiency. Landscaped area includes special landscaped area in square feet. MAWA ETo 0.62 0.7 LA 0.3 The additional ET adjustment factor for a special landscaped area (1.0 -0.7 = 0.3) SLA Special landscaped area in square feet. Show Calculation: = (40.0) (0.62) [(.55 X 1,620)] = (24.8) (891) = 22,097 MAXIMUM APPLIED WATER ALLOWANCE= ___ _.2.,.2,,.09"-7 ____ GALLONS PER YEAR Hydrozone Table for Calculating ETWU Please complete the hydrozone table(s). Use as many tables as necessary. CITY OF CARLSBAD ESTIMATED TOTAL WATER USE ETWU Hydrozone Number (1 - 5 with SLA Zone Below -use as many tables as necessa to com lete all h drozones Evapotranspiration Rate ETo • Conversion Factor (Step 1 x Step 2) Plant Factor (PF)** (From WUCOLS) 0/LW -HW 0.1 -0.8 Area of Hydrozone (sq. ft. HA (Step 4 x Step 5) Irrigation Efficiency IE ... (Step 6 + Step 7) {Total All Step 8 + Total SLA s . ft. in Ste 5 {Step 3 x Step 9) Estimated Total Water Use in gallons per year (ETWU) -Total shall not exceed MAWA Ero• West of/-5 = 40. O Process Step No. Below 1 2 3 4 5 6 7 B 9 10 .BO 325 260 .BO 325 852 21,130 East of 1-5 end West of El Camino Real= 44.0 Eest of El Camino Real = 47. 0 App/leant may provide a different ETo if supported by documentation subject to approval by the City Planning Division " Plant Factor & Water Use 0. 1 = VLW -Very Low Water Use Plants 0.3 = LW-Low Water Use Plants 0. 5 = MW -Moderate Water Use Plants 0. 8 = HW -High Water Use Plants 2 3 40.0 0.62 24.8 .50 .30 279 938 140 281 .80 .80 175 352 ***IE Micro-spray = . 80 Spray= .55 Rotor= .70 Bubbler= . 75 Drip= .80 4 5 SLA .00 78 .OD .00 Applicant may provide a different IE if supported by documentation subject to approval by the City Planning Division (Turf and Landscape Irrigation Best Management Practices, April 2005) X HYDROZONE DATA LEGEND SYMBOL DESCRIPTION HIGH WATER USE, DRIP IRRIGATION • 325 S.F. :,f"j;,'2';;72'.:;f-77Fe::!z::1!,~d'7=;>;,,.,.J~~..,..,..,,'....!...-;,-.,.....,..ij==::z:Jz=:zirLL.'LL.ij½½~i".-;...u..-LWU • .80 PLANT FACTOR (PF) g I ,ri a 0 0 ,ri a s (D) LWU (D) LWU (NI) HIGH WATER USE -STREAM ROTOR IRRIGATION • 00 S.F. • .80 PLANT FACTOR (PF) MEDIUM WATER USE, DRIP IRRIGATION • 279 S.F. • .50 PLANT FACTOR (PF) MEDIUM WATER USE· STREAM ROTOR IRRIGATION • DD S.F. • .50 PLANT FACTOR (PF) LOW WATER USE, DRIP IRRIGATION • 936 SF. • .30 PLANT FACTOR (PF) ---1---+--~,v'-----+----1---•---1---;, a LWU --l----l---llf 16--, I ------1--Jn __________ r----"'-----L _ -, I r ~. LWU I / / I ' I • I G ----+ G -"---G --'- 5 -- ~ I ==p ,----,L-/ w w w --1/1/ --~ ·,\\ . j°) -; ~ I I . .... .. I LWU I (NI) / I ,-;;:c..\, 'c,, ,/ ~--~~~,J.~a -o >I , n~~~=---~~~~ 2725 Jtifferaon street, suite 15b ci.rlabed, ca IJ:2003 phone: 760.720.9337 faK: iEl0.720.9505 Ex iration Date: 4130123 E; (NI) tj' M z I APP IRJC'1l'VlE[)) CQi\jSTRU(:~u=~ioi~·\~ s~~T 10 0 5 10 20 ~ I I I 40 I SCALE: 1'=10'-0" FEET LOW WATER USE, STREAM ROTOR IRRIGATION • DO S.F. • .30 PLANT FACTOR (PF) LOW WATER USE, NO IRRIGATION • 78 S.F. • .DO PLANT FACTOR (PF) APPROVED FOR /RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUILT" RCE---EXP.----DATE REVIEWED BY: INSPECTOR DATE 1------+---1-----------l---.1-----L-_J_____J ~ CITY OF CARLSBAD ~ ~ PLANNING DIVISION ~ :;:LA:;:N;D;S;C:;:A;;,PE;;l;:;M:;PR;O;:V;E;:;M;EN:;:;T;;P~LA~NS~FO~R::: :::::=:===='-'==~ HEMLOCK COAST HOMES 320 HEMLOCK AVENUE, CARLSBAD, CA WATER CONSERVATION PLAN 1------l---l---------------1------1----1------1--...I I APPROVE~ d~ l---l---+----------------1-----+---+---_j_-----.l ~-P~LA:::N~Nl:::NG:::::::=~=;--;::=~:::::::===:::====:::::;-;::::===~ DWN BY: JSS PROJECT NO. DRAWING NO. 1/21:/2.1 CHKD BY: JSS RVWD BY: LPC2021-0012. PUD2020-0001 530-5L DATE INITIAL DESIGNER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL PLOT DATE: 7/8121 2021-03-30_Hemlock Homes TIiie Block.vwx