HomeMy WebLinkAboutPRE 2021-0025; 3495 MADISON STREET; Preliminary ReviewCONTRACTOR RESPONSIBILITY "CONTRACTOR RESPONSIBILITY'' EACH CONTRACTOR OR SUB-CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF THE WIND AND /OR SEISMIC RESISTING SYSTEM THAT IS LISTED IN THE STATEMENT OF SPECIAL INSPECTIONS SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK REQUIRING SPECIAL INSPECTION. THE CONTRACTORS STATEMENT OF RESPONSIBILITY SHALL CONTAIN THE FOLLOWING 1. ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS. 2, ACKNOWLEDGEMENT THAT CONTROL WILL BE EXERCISED TO OBTAIN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS APPROVED BY THE BUILDING OFFICIAL. 3. PROCEDURES FOR EXERCISING CONTROL WITHIN THE CONTRACTOR'S ORGANIZATION, THE METHOD AND FREQUENCY OF REPORTING AND THE DISTRIBUTION OF REPORTS AND SCHEDULE 4. IDENTIFICATION AND QUALIFICATIONS OF THE PERSON(S) EXERCISING SUCH CONTROL AND THEIR POSITION(S) IN THE ORGANIZATION" GENERAL NOTES 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO STARTING WORK, AND SHALL NOTIFY THE DESIGNER OF DISCREPANCIES OR INCONSISTENCIES. 2. THE STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE, THEY DO NOT REPRESENT THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT LIMITED TO, BRACING AND SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, CONSTRUCTION LOADS OF MATERIALS, ETC. THE CONTRACTOR, AT NO EXPENSE TO THE OWNER, SHALL RETAIN QUALIFIED PROFESSIONALS TO DETERMINE FIELD LAYOUT OF THE BUILDING ELEMENTS, AND THE ADEQUACY OF ALL PROPOSED BRACING AND SHORING. 3. OBSERVATION VISITS TO THE SITE BY THE ENGINEER SHALL NOT INCLUDE OBSERVATION OF SAFETY METHODS, BRACING OR SUPPORT. 4. PLAN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS. 5. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND STANDARD DETAILS, 6. CLARIFICATION SHALL BE REQUESTED FROM THE ENGINEER FOR ALL WORK INDICATED ON THE PLANS THAT IS NOT SPECIFICALLY DETAILED, AND IS NOT SIMILAR TO WORK THAT IS DETAILED. 7. SEE EXISTING AND/ OR OTHER PLANS FOR SIZE AND LOCATION OF ALL DOOR AND WINDOW OPENINGS, SIZE AND LOCATION OF ALL NON-BEARING PARTITIONS, SIZE AND LOCATION OF ALL CURBS, DRAINS, DEPRESSED AREAS, SLOPES AND ELEVATION CHANGES, CHAMFERS, GROOVES, INSERTS, ALL FINISHES, AND SIZE AND LOCATION OF ALL FLOOR AND ROOF OPENINGS. 8, SEE OTHER PLANS FOR ALL WATERPROOFING REQUIREMENTS. THE ENGINEER IS NOT RESPONSIBLE FOR WATERPROOFING DETAILS AND SPECIFICATIONS. 9. MECHANICAL, PLUMBING, AND ELECTRICAL REPAIRS SHALL BE UNDER SEPARATE PERMIT AND SHALL BE PERFORMED BY A LICENSED CONTRACTOR LICENSED IN THE APPROPRIATE FIELD. 10. MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOORS OR ROOFS. LOADS SHALL NOT EXCEED DESIGN LOADING FOR SUPPORTING MEMBERS. 11. UNLESS APPROVED BY THE LOCAL C.B.O. OR BUILDING DEPARTMENT (PER CPC SECTION 301.2.5.) PEX IS NOT AN APPROVED BUILDING MATERIAL. CONSTRUCTION REQUIREMENTS 1. 3. 4. 5. 6. 7. BATHROOM A. ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR FIXTURES SHALL BE PROVIDED WITH AN EXHAUST FAN WITH A MINIMUM CAPACITY OF 50 CFM. DUCTLESS FANS ARE UNACCEPTABLE. 8. CLEARANCE FOR WATER CLOSET TO BE A MINIMUM OF 24-INCHES IN FRONT, AND 15-INCHES FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION. CPC 402.5 C. WATER CLOSET SHALL HAVE AN AVERAGE CONSUMPTION OF A MAXIMUM OF 1.28 GALLONS OF WATER PER FLUSH. CPC 403.2.1 D. RESIDENTIAL FAUCETS SHALL NOT EXCEED A WATER SUPPLY FLOW RATE OF 1.5 GALLONS PER MINUTE MEASURED AT60 PSI. AND 0.8 GALLONS PER MINUTES AT 20 PSI. E. SHOWER HEADS SHALL NOT EXCEED A WATER SUPPLY FLOW RATE CPC 403.7 OF 2.0 GALLONS OF WATER PER MINUTE AT 80 PSI. CPC 408.2 F. WALL COVERING OF SHOWERS OR TUBS WITH SHOWERS SHALL BE OF SMOOTH, NONABSORBENT SURFACE EXTENDED TO A HEIGHT NOT LESS THAN 6 FEET ABOVE THE FLOOR CRC R307.2, CBC 1210.2.3 G. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FEET) OR MORE IN CLEAR FLOOR AREA, AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. CPC 408,6 H. KITCHEN SHALL HAVE A CLEAR PASSAGEWAY OF NOT LESS THAN 3 FT. CBC 1208.1 I. PROVIDE LOCAL EXHAUST SYSTEM VENTED TO OUTDOORS WITH RA TE= 100 CFM. CEC 150(0), ASHRAE STD. 62.2. J, FAUCETS AT KITCHENS SHALL NOT EXCEED A WATER SUPPLY FLOW RATED OF 1.8 GALLONS PER MINUTE MEASURED AT SO PSI. CDC 403.6 SAFETY GLAZING SHALL BE PROVIDED AT THE FOLLOWING HAZARDOUS LOCATIONS CRC R308.4 (CBC 2406.4): A. WHEN LOCATED WITHIN SO-INCHES OF THE FLOOR SURFACE IN TUBS, SHOWERS, SAUNAS, OR STEAM ROOMS WHEN LOCATED WITHIN SO-INCHES OF THE FLOOR SURFACE IN TUBS,SHOWERS, SAUNAS, OR STEAM ROOMS. B. WHERE GLAZING AREA IS MORE THAN 9 SQ. FT. IN AREA, WITH THE BOTTOM EDGE LESS THAN 18-INCHES ABOVE THE FLOOR AND TOP EDGE MORE THAN 36-INCHES ABOVE FLOOR. ELECTRICAL A. ALL RECEPTACLE OUTLETS IN BATHROOMS, ABOVE KITCHEN COUNTERTOP, CRAWL SPACES. GARAGE, ROOFTOPS, OUTDOOR OUTLETS, WITHIN 6-FEET OF WET BAR SINK/LAUNDRY SINK TO BE PROTECTED BY GROUND FAULT CIRCUIT INTERRUPTER (GFCI). CEC 210.8. 8. ALL RECEPTACLE OUTLETS ARE REQUIRED TO BE LISTED TAMPER RESISTANT. (CEC 406.12 AND 210.52) C. COMBINATION TYPE AFCI CIRCUIT BREAKERS ARE REQUIRED FOR ALL 120 VOLT SINGLE PHASE 15/20 AMP BRANCH CIRCUITS. EXCEPT FOR BATHROOMS, KITCHENS, GARAGES, OUTDOORS, AND LAUNDRY ROOMS. (CEC 210.12(6)) D. AT A MINIMUM, ONE DEDICATED 20 AMP CIRCUIT IS REQUIRED FOR A BATHROOM. (CEC 210.11(C)(2)) E. A GFCI PROTECTED RECEPTACLE IS REQUIRED WITHIN 3 FEET OF THE EDGE OF EACH BASIN IN A BATHROOM. (CEC 210.52(D)) F. RECEPTACLE OUTLETS ARE NOT ALLOWED WITHIN OR OVER A BATHTUB OR SHOWER STALL. (CEC 406.9 (C)) G. SUBPANELSARE NOT ALLOWED TO BE LOCATED IN BATHROOMS OR CLOTHES CLOSETS. (CEC 240.24(D) AND 240.25(E)) H. CIRCUITS SHARING A GROUNDED CONDUCTOR (NEUTRAL) WITH TWO UNGROUNDED (HOT) CONDUCTORS MUST USE A TWO POLE CIRCUIT BREAKER OR AN IDENTIFIED HANDLE TIE. (CEC 210.4(6)) GROUP NON-CABLE CIRCUITS IN PANEL (CEC 210.4(D)) I. THE KITCHEN COUNTER TOP RECEPTACLES MUST HAVE A MIN. OF 2 DEDICATED 20 AMP CIRCUITS. (CEC 210.52(B)) J. THE RECEPTACLES IN THE DINING AREA, PANTRY, OR BREAKFAST NOOK MUST BE SUPPLIED BY DEDICATED 20 AMP CIRCUITS. (CEC 210.52(6)) K. KITCHEN COUNTER TOPS 12 INCHES OR WIDER MUST HAVE A RECEPTACLE OUTLET. (CEC 210.52(C)) L. KITCHEN COUNTER TOPS MUST HAVE RECEPTACLE OUTLETS SO NO POINT ALONG THE COUNTER WALLS IS MORE THAN 24 INCHES FROM A RECEPTACLE. (CEC 210.52(C)) M. ISLAND AND PENINSULAR COUNTER TOPS MUST HAVE AT LEAST ONE RECEPTACLE. (CEC 210.52(C)(1) AND (2)) N. KITCHEN COUNTERTOP RECEPTACLES SHALL BE READILY ACCESSIBLE, AND LOCATED NO MORE THAN 20 INCHES ON OR ABOVE, OR MORE THAN 12 INCHES BELOW THE COUNTERTOP SURFACE. (CEC 210.52(C)(5)) 0. THE SPACING FOR GENERAL RECEPTACLE OUTLETS MUST BE LOCATED SO THAT NO POINIT ON ANY WALL OR FIXED GLASS IS OVER 6 FEET FROM A RECEPTACLE OUTLET. (CEC 210.52(A)) P. HALLWAY 10 FEET OR MORE MUST HAVE AT LEAST ONE RECEPTACLE OUTLET. (CEC 210.52(H)) Q, LAUNDRY ROOMS MUST HAVE AT LEAST ONE DEDICATED 20 AMP RECEPTACLE CIRCUIT. (CEC 210.11 (C) (2)) SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (R314.3): A. IN EACH SLEEPING ROOM. 8. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. C. ON EACH ADDITIONAL STORY, INCLUDING BASEMENTS AND HABITABLE ATTICS. SMOKE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN ACCORDANCE WITH SECTIONS R314.4 & R314.5. CARBON MONOXIDE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (R315.1.4): A. OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S). B. ON EVERY LEVEL OF THE DWELLING UNIT INCLUDING BASEMENTS. EMERGENCY EGRESS WINDOWS SHALL BE MIN. 5.7 SQ. FT, MIN. NET WIDTH 20" AND MIN. NET HEIGHT 24", BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44" ABOVE FINISHED FLOOR. (R310) WINDOWS ABOVE FIRST LEVEL AND HAVING SILL HEIGHT< 24" SHALL BE PROTECTED BY GUARDS (R312.2.1) -11~ DIMENSION NOTES 1. ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F .D.S.) UNLESS NOTED OTHERWISE . 2. DO NOT SCALE FROM DRAWINGS. 3. ANY INCONSISTENCIES OR UNFORESEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION. 4. ALL DOORS AND WINDOWS DIMENSIONED TO CENTERLINE OF CLEAR OPENING UNLESS NOTED OTHERWISE. 5. ALL NON-DIMENSIONED DOORS SHALL BE OFFSET FROM THE HINGE-SIDE WALL TO ALLOW FOR (2) 2X4 STUDS AT THE JAMB. (U.N.O.) 6. ALL NON-DIMENSIONED WINDOWS TO BE FLUSH TO ADJOINING WALL OR CENTER IN TO ROOM UNLESS NOTED OTHERWISE. 7. ALL CASEWORK DIMENSIONS TO FACE OF FINISH. CALIFORNIA RESIDENTIAL CODE NOTES 1. EXTERIOR DOORS MUST OPEN OVER A LANDING NOT MORE THAN½" BELOW THE THRESHOLD. EXCEPTION: PROVIDING THE DOOR DOES NOT SWING OVER THE LANDING THE LANDING SHALL NOT BE MORE THAN 8" BELOW THE THRESHOLD. 2. LANDINGS AT DOORS SHALL HAVE A LENGTH MEASURED IN DIRECTION OF TRAVEL OF NOT LESS THAN 36 INCHES. TYP. CRC R311.3 3. STORAGE/CLOSET UNDER STAIR, PROVIDE ONE LAYER OF 5/8 TYPE "X" GYP. SD. AT WALL AND UNDERSIDE OF STAIR TO ACHIEVE 1 HR OF FIRE PROTECTION 4. GARAGE, PROVIDE 1 LAYER OF 5/8 TYPE "X" GYP. BO. AT GARAGE WALLS, CEILINGS, AND SUPPORTING STRUCTURAL MEMBERS SEPARATING THE GARAGE AND LNING AREAS TO ACHIEVE 1 HR OF FIRE PROTECTION APPLICABLE STANDARDS: 2016 CALIFORNIA RESIDENTIAL CODE (CRC) 2016 CALIFORNIA PLUMBING CODE (CPC) 2016 CALIFORNIA MECHANICAL CODE (CMG) 2016 CALIFORNIA BUILDING CODE (CBC) 2016 CALIFORNIA ELECTRICAL CODE (CEC); 2016 CALIFORNIA GREEN BUILDING VICINITY MAP NORTH ABBRIVIATIONS A/C AIR CONDITIONER L.V.L. A.F.F. ABOVE FINISHED FLOOR MAS. A.F.G. ABOVE FINISHED MTL. GRADE MIN. BOT. BOTTOM N B.O.F. BOTTOM OF FOOTING N.T.S. B.O.W. BOTTOM OF WALL O.C. CC. CENTER TO CENTER O.D. CL. CLOSET OPNG. CLG. CEILING CMU CONCRETE MASONRY PCC UNIT DEMO DEMOLISH PL. D.S. DOWNSPOUT P.L. DIA. DIAMETER PLYWD. DIM. DIMENSION PTD: DN. DOWN RC DP: DAMP PROOFING E EXISTING RD: E.F. EXHAUST FAN R.D.L. EXC: EXCAVATE RO. EXT. EXTERIOR R.O.W. F.A.U. FORCED AIR UNIT REINF. F.D. FLOOR DRAIN SAN. FIN. FINISH S.D. F.F.L FINISHED FLOOR SECT. LEVEL SHT.- GALV. GALVANIZED SHT'G. G.C. GENERAL SQ.FT. CONTRACTOR SQ. IN. G.F.C.I. GROUND FAULT STD. CIRCUIT INTERRUPT STL. G.F.I. GROUND FAULT S.Y. INTERRUPT T&B: G.T. GLAZED TILE T.O. GYP. GYPSUM UNO H.V.A.C. HEATING, VENTING AND AIR CONDITIONING V.B. H.W. HOT WATER W.C. IN INCH CLOSET) INSUL. INSULATION WD. INT. INTERIOR WDW. JST. JOIST W.I.C. LFT. LINEAR FEET WP. LTG. LIGHTING WS: OR W/O: LAMINATED VENEER LUMBER MASONRY METAL MINIMUM NEW NOTTO SCALE ON CENTER OUTSIDE DIAMETER OPENING OR ROUGH OPENING PORTLAND CEMENT CONCRETE PLASTER PROPERTY LINE PLYWOOD PAINTED REINFORCED CONCRETE ROOF DRAIN ROOF DRAIN LEADER ROUGH OPENING RIGHT OF WAY REINFORCED SANITARY SMOKE DETECTOR SECTION SHEET SHEATHING SQUARE FEET SQUARE INCHES STANDARD STEEL SQUARE YARD TOP AND BOTTOM TOP OF UNLESS NOTED OTHERWISE VAPOR BARRIER TOILET (WATER WOOD WINDOW WALK-IN CLOSET WEATHERPROOF WEA THER--STRIPPING WATER STOP WITHOUT AREA PLAN/ LOT COVERAGE Name (N) GARAGE DECK FIRST FLOOR MOD SECOND FLOOR MOD I p I I 9 MODULAR LIVING AREA Copy 1 I Area Level 505 SF F.F. MODULAR 180 SF Second Floor 1250 SF F.F. MODULAR 1800 SF Second Floor 3735 SF SE OWNER: KEVIN SLADEK KEVIN@MOD4D2.COM MODULAR MANUFACTURER JIM SHERIDAN DRAFTER: EVERETT SMITH DESIGNS 3437 POTOMAC CT PERRIS, CA 92570 951.323.2187 County: Parcel # (APN): SAN DIEGO, CA 204-172-22-00 Owner Name: SLADEK KEVIN W & EMILY Mailing Address: Legal Description: 3495 MADISON ST CARLSBAD CA 92008 TR 775 BLK 43*LOT 32*ALL PALM ST CLSD ADJ* Bedrooms: Units: Baths (Full): Stories: Bldg/Liv Area: Lot Sq Ft: Effective Year: Quadrant: Zoning: General Plan Land Use: Local Facility Management Zone: Drainage Area: B 3 1 2 1 1,182 11,484 1961 NW RD-M R-15 1 Sewer District: CBD Water District: CMWD School District: CA Park District: 1 Fire District: 1 Bridge Thoroughfare District: NA Census Tract: 179 Master Plan: NA Specific Plan: NA Sewer Benefit Area: NA In Coastal Zone: NO In Redevelopment Zone: NO In Beach Zone: NO In Fire Zone: NO In Visitor Zone: NO In Barrio Area: YES In Village Area: NO Village District: NA SCOPE: -;-:, ~ ,_;-... -..,.. ""'. .... \ -~--...,._) ' ,:,_ . .'.-~ '-'.::-.. -·· "" -~ ::.._ __ ., ./ 1. NEW CONSTRUCTION FOR MODULAR HOME SHEET INDEX Sheet Number I Sheet Name AO Titile Sheet A1 Site Plan A2 PROPOSED PLANS A4.1 Elevations N & S A4.2 Elevations E & W A4.3 PERSPECTIVE AS Section A5.1 Deck Details A5.2 Stair Details GN1 Structural Notes (N) HOUSE: 1250 1800 3050 SF HOUSE x2 (N) GAR: 505 SF x2 (N) DECKS 180 SF x2 HOU GAR DEC TOT 3050 + 505 + 180 = 3735 SF PREPARED BY: RIVERSIDE COUNTY, CA /L:95~-3,;:_21. 87 ~J)JJ-if Ofr~ Email: everett@everettsmithdesigns.com ThiS document, and the ide.is and designs incorporated herein, as an instrument crl' profession<'( ser.tice, is the property of Everett Smith, and is not lo be used in whole or in pa'i, for any ether ?K>Ject wHhoU: the written a.rthorizatlor, af Everett Smilh/ ESDESIGNS. All Rights Reserved PROJECT: REVISIONS: No. Description Date 1 Revision 1 Date 1 PROJECT ADDRESS: 3495 MADISON ST CARLSBAD CLIENT NAME: MOD4D2, LLC Titile Sheet Project number 19-1974 Date 5/31/2021 3:50:01 PM Drawn by EDS Checked by ES AO Scale 1" = 20'-0" Z:\Shared\Everett Smith Designsl_ES Design Jobs\ 19-197 4 Great Oaks 3484 Roosevelt St Cartsbad Ca\ 19-197 4 3495 Madison St Carlsbad-3.rvt :;;; a. -<;=! 0 "' io -"' 0 £:! -~ "' (E) OVERHEAD ELECTRICAL LINE ~ I I I i ,: \ (E) WATER VALVE ii '' ' ----------..---------------~--\ I -I ,-h (E) ALLEY ACCESS ,'1' (El Site Plan '--Y 1" = 10'-0" I I I I I I I I -r CJ) N ' I \ \ I \ I . I ' ~/ L ----------""'""----------- ,' 'f I I I I I I I I I I I I I I I I I I I I I I I _ _J I ' (N) WATER VALVE----, I I I 5' -0" \ 80' -0" 30' -0" 5' -O" 5' -O" (N)WATERVALVE \ 30' -0" \ I I 5' -0" \ ~-----\ --,i.--;.--___.,.....,_ ~\----. \ ---/I--\-+----+-------------- 1 n -'-r T 1, ~ (Nl ELEC~ANEL ~ i I 6 ' 0 N I LJ I /; & METER ' I : ~ : 1: ~ : I (E) DRIVEWAY I I / I (N) DRIVEWAY I I I ~ I I \ I I ~ , ' •• , W--,• ~ 7 ----,o .> ---e,• I i ~----,---□----~ ~iJ"I-'.--, ,, ---[!--1 I I I I' I N I (N)GAS _e::±Y~CJHH'Y"III' ·' I : METER , : /: 3'-01~\ ,'-' : L_ ____________ ...J : I ~N· '---------------'-' := -II N 11- ~ll I I I ~j I ,--, :~ .1-__ 1,l --...., / o, I t:~: PROPOSED (N) HOUSE l~l -l-1 PROPOSED (N) HOUSE it::' __ -__ -~: RESIDENCE #1::!!!!!!..,_-cH-·"'r-;;1-___ ----'j,--~i;::1-.....,!!CRESIDENCE #2 :~:: --~• I V IQ 1o _ CJ I V I:::: --~ ~ ~ ~ ~ c_ llu... __ ::j L\ t:: I I REF.II I I I I I [III_J I '-IIIIJ I I 0 . ---------------='1aa-il1~tt-<f'Jl-+-H-iia::-------------:~ --------------~ 0 -~ " '.P. 0 ~ I I I I I 0 f I• iio -I ....---------F+•~----------= I I ~ I' I I I (E) ALLEY ,CCESS I . i I ~ I I I : I I I i I I I I I : I I I i I I I I I I I I I I I I i I I I I I : I I I i I I I I .. I I I I I I I I I I I I I • II I I ID I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I [El] I I I I I I I I I I I I I I I I I I I I I I I I I I l_ l L.:... ------------------=.,-=----------..... 8 -0" -,'----------------11------------------1\I-- @ (N) Site Plan 1" = 10'-0" ,.C ' r+----.------t _, I L_ _____ __.I =i======= I p I I I 9 I I ® FIRST FLOOR AREA 111 = 201-0 11 PREPARED BY: RIVERSIDE COUNTY, CA /L:951-3~2187 8/ffe~CY~ Email: everett@everettsmithdesigns.com This document, and the ideas and deGl9ns incorporated herein, as an Instrument of professbnal service, is the property al Everett Sm~h. and is not to be used in whole or In part, for any other project without the written authorization of Everett Smith/ ESDESIGNS. All Rights Reserved PROJECT: REVISIONS: No. Description Date PROJECT ADDRESS: 3495 MADISON ST CARLSBAD CLIENT NAME: MOD4D2, LLC Site Plan Project number 19-1974 Date 5/31/2021 3:50:02 PM Drawn by Author Checked by Checker A1 Scale As indicated Z:\Shared\Everetl Smith Designsl_ES Design Jobs\19-1974 Great Oaks 3484 Roosevelt St Carlsbad Ca\19-1974 3495 Madison St Carlsbad-3_rvt -------------------------------------- ::;; a. N 0 0 ~ "' -N 0 !I'.:! -:is I I I I I I I I I I I I I I -~-~'------~1-------------------+------- ! I I I I I I I I L -----tJ ------~~~~~qt -- I I ' I ' I I I I I I I I I [9 I I --,.-t;-1 ' (D Proposed First Floor 3/16" = 1 '-0" 0 C!J t;-1 0 C!J ' I I I I I I I ' I ~-------------------------~ oo OG ill R::F. • ' - I I I [Oj 0 ' 0 ' Co - __ J_ __ I I I I I I I : I -----+------------------------------------ 1 I 15' O" <t. 15' O" I J' .-- "' ' ;... - -' io N ' "' 0 N ' .,_ ' Co -y- ~,,,,,''""'""'"'' i ~ ' ' ' f i i flllf i i i --- ' ' ' ' ' j ' i I 'I ; ! --- " I 1 f ' i 1 t ' ' ' ' l I ' t ' ,, ' i i i ! ' i'. I \ ' " I t \ . . ,,,. '"''" @ Second Floor 3/16" = 1 '-0" - ;-,;'>,•H•'h·~r-•,c., . -··- LJ~ J. - I I I ,,•,. '., , .. ,,~·-··""'' ""'""'' '""''"· _,, ··'"'""''"~''•-·,' ' ' .,•-,-,-, .. ,, """-"owo' •>,>·•'"t•'f -,',,"Yd•N%'• 1 ' i -\ i I ! ] i _// ~-6" ,,-" i ; A G) I G) . [] ' i ' ' i I ' { ' ~ \ ! _JI ' ' ' ' ) i @] Do ~ ; I I t I I I 0 ' M.CLOSET I ~ ,1)4 SF __ _j \ ' ( i I } ,0 0 ~ ~ 6' -11" ,' \ b MASTER BATH ' i .. 112 SF ( D I>< ,·-v,, ,,,. ,,,. ··~,'-.•·•--·,, '"'" \ ''"'' "';, ,-,;a.,.' ,.,._,,." ·••-•~'"''•' '•'"' ,;, .,,-,,.,, .. ,--,-.. , ,,,,..,_, .. ,_,P,~ 30' -0" - I ' I C . ~ I I 0 I ' N I - I I I ~ I -' Co I I I I jl.. I ' "' I -I / I. 0 lb "' -I b I ' I io ---+ - I I I I I I [o I ' 0 N I I I I I I I I;.. ' I"' • r PREPARED BY: RIVERSIDE COUNTY, CA 951-3~2187_ .JJ_ '-:=:---,_,,l,;--JJ,lj YlJ,/Jllb Email: everett@everettsmithdesigns.com This document, and tt,e ideas and :lesigns 1neorpora:ec1 herein. as an instrument of professional service. is the property of E\lerett Smlh, and is not to be used in whole or i"7 part, for <f'IY other project withcul: 1he wrlten authorization of Everett Smihl ESDESIGNS. All Rights Re~er.ed PROJECT: REVISIONS: No. Description Date PROJECT ADDRESS: 3495 MADISON ST CARLSBAD CLIENT NAME: MOD4O2, LLC PROPOSED PLANS Project number 19-1974 Dale 5/31/2021 3:50:04 PM Drawn by Author Checked by Checker A2 Scale 3/16" = 1'-0" Z:\Shared\Everett Smith Designsl_ES Design Jobs\19-1974 Great Oaks 3484 Roosevelt St Carlsbad Ca\19-1974 3495 Madison St Carlsbad-3.rvt ::e a. ?!! 0 "' ;.; -N 0 C:! -"2 "'