HomeMy WebLinkAbout2641 GATEWAY RD; 101; CBC2020-0337; PermitBuilding Permit Finaled
Ccityof
Carlsbad
Commercial Permit
Print Date: 04/21/2021 Permit No: CBC2020-0337
Job Address: CARLSBAD, CA 92009-1754 Status: Closed -Finaled
Permit Type:
2641 GATEWAY RD, # 101,
BLDG-Commercial
2131912500
Work Class: Tenant Improvement
Parcel#:
Valuation:
Occupancy Group:
#of Dwelling Units:
$95,008.96
Track#:
Lot#:
Project#:
Plan#:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check#:
Occupant Load: Plan Check#:
Code Edition:
Sprinkled:
Project Title:
Description: PANDA EXPRESS: 1,468 SF T.l. SAME USE
FEE
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Property Owner:
REGENCY BRESSI LLC
100 WILSHIRE BLVD, # 700
SANTA MONICA, CA 90401
ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL
FIRE Plan Review Per Hour -Office Hours
MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-COMMERCIAL
Total Fees: $1,308.23 Total Payments To Date: $1,308.23
Applied:
Issued:
Finaled Close Out:
Inspector:
Final Inspection:
Contractor:
09/04/2020
11/04/2020
CRenf
04/21/2021
ROCKWALL CONSTRUCTION COMPANY
4345 E LOWELL ST, # STE H
ONTARIO, CA 91761-2222
(909) 972-8216
Balance Due:
AMOUNT
$609.78
$426.85
$60.00
$136.00
$45.00
$4.00
$26.60
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f \ www.carlsbadca.gov
---
( City of
Carlsbad
COMMERCIAL
BUILDING PERMIT
APP LI CATION
8-2
:::~ ~.~::·~tiflt>J
PC Deposit
Date _q_,,/_,,l/-+-/j,"""'-0 __
Job Address 2641 Gateway Rd. Suite: Suite 101 APN: _2_13_1_9_12_5_o_o ___ _
Tenant Namef_a_n_d_a_E_x __ p_re_s_s ______________ CT /Project#: _______ lot#: ___ _
Occupancy:_B ____ Construction Type:_V_-_B __ Fire Sprinklf!!rs: 0 YES O NO Air Conditioning: 0 YES O NO
BRIEF DESCRIPTION OF WORK: Non-Bearing Partitions, Gyp. Board, Ceiling, Walk-in Cooler, Walk-in Freezer, Floor & Wall Finishes
Lighting Fixtures, Plumbing Fixtures, Underground Plumbing, Gas Piping, HVAC Unit, EF, MUA, Condenser, & Type-I Hood.
D Addition/New: ___________ New SF and Use, __________ New SF and Use,
_____ Deck-SF, Patio Cover SF (not including flatwork)
[Z] Tenant Improvement: 1,468 SF, Existing Use _B ______ Proposed Use _B ______ _
______ SF, Existing Use ______ Proposed Use ______ _ ,.
D Pool/Spa: _____ SF Additional Gas or Electrical Features? ____________ _
D Solar: ___ KW, __ Modules, ___ Mounted, Tilt:OYON, RMA:OYON, Panel Upgrade: OYQN
D Plumbing/Mechanical/Electrical Only: ________________________ _
D Other: _________________________________ _
APPLICANT (PRIMARY CONTACT)
Name: Miguel Topete
Address: 1000 Corporate Center Dr. Suite 550
City: Monterey Park State: CA Zip: 91754
Phone: 626.288.6898
Email: miguel@garywang.com
DESIGN PROFESSIONAL
Name: Gary Wang & Associates, Inc.
Address: 1000 Corporate Center Dr. Suite 550
City: Monterey Park State: CA Zip: 91754
Phone: 626.288.6898
Email: gary@garywang.com
Architect State License: C-32569 ------------
PROPERTY OWNER
Name: Flocke & Avoyer Commercial Real Estate
Address: 6165 Greenwich Dr. Suite 11 O
City: San Diego State:~Zip: _9_21_2_2 __ _
Phone: 858.875.4669
Email: skeith@flockeavoyer.com
CONTRACTOR BUSINESS
Name: £cx:x:¥.l~W-Col--6-tf:J.,..(J :Li> !>,) /2a.,. e AQ \
Address: 4 3. 4 (;'. G-~ t LL c:r , # \.--\
City: 0 NUr'-."l:.D State:~Zip: q \ t\ b \ -< 7
Phone: <;;'oC\ -'\n) -€>4-l 6
Email: €.C: x;,,,.j I:\µ.,, CO@ #L lQv11
State license: /3 Bus. license: '7 '7 '1 / .) ti
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to Its
Issuance, also requires the applicant for such permit to file a signed statement that he/she Is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.S by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500}).
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
8-1 Page 1 of 2 Rev. 03/20
~ ......... -
( OPTION A): WORKERS'COMPENSATION DECLARATION:
I hearby affirm under penalty of perjury Q!1f of the following declarations: 01 have and will maintain a certificate of consent to selt·lmure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued.
~e and will maintain worker's compensation, as required by Section 3700 o1 the Labor Code, for the performance of the work fot which this permit Is Issued.
My workers' compensation Insurance carrier and policy number are: Insurance Company Niime: 5"l A J1. C,llJ.i€~c::;,p.."1'\M bb,t,.,) D
Policy No. C\ ~ 'O l\,~). -). l) )R E11plratlon Date: 7... \ \ l ~ )..., \
0 Certificate of Exemptlon: I certify that In the performance of the work for which this permit is issued, I shall not emplov any person in any manner so as to be come
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage ls unlawful, and shell subject an employer to
criminal penalties and civil fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for In Section 3706 of the l..lbor Code,
interest and attorney's fees.
CONTRACTOR SIGNATURE: ,0l?,ol2-02P ( \ \
( OPTION B ): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's Ucense Law far the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not Intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who does such work
himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement Is sold within
one year of completion, the owner-builder wlll have the burden of proving that he did not build or Improve for the purpPSe of sale).
0 I, as owner of the property, am exciuslveiy contracting with licensed contractors to construct the project /Sec: 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and contracts f.P',Such projects with contractor(s) licensed
pursuant to the Contractor's license Law). •
0 I am exempt under Section _______ B.uslness and Professions Code for this reason:
l. I personally plan to prollide the major labor and materials for construction of the proposed property Improvement. Ove:s ONO
2. I (have/ have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (Include name address/ phone/ contractors' llcense number):
4. I plan to prolllde portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/
contractors' ncense number): s. I will provide some of the work, but I have contracted (hired) the following persons to provide the work Indicated (include name/ address/ phone/ type of work):
OWNER SIGNATURE: □ AGENT DATE: _____ _ -------------------------
CONSTRUCTION LENDING AGENCY, IF ANY:
1 hereby affirm that there is a construct Ion lending agency for the performance of the work this permit ls issued (Ser;. 3097 (I) Civil Code).
Lender's Name: ____________________ lender's Address: ____________________ _
ONLY COMPLETE THE FOLLOWING SECTION FOR NGN•RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials reglsttatlon form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley• Tanner Hazardous Substance Account Act? I Yes / No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes / No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes/ No
IF ANY OF niE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have read the application and state that the above information ls correct and that the Information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction.
I hereby authorize representative of the Oty of Carlsbad to enter upon the above mentioned property for inspection purposes. I A150 AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE OTY OF CARLSSAO AGAINST ALL UABIUTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAI0CITY IN CONSEQUENCE OF
THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit Is required for eJU:3vatlons over s·o• deep and demolition or construction of structures CM!r 3 stories in height.
EXPIRATION: Every permit Issued by the Building Official under the prOlllsions of this Code shall expire by limitation and become null and void If the building or wor1< auttiorlzed ·
by such permit Is not commenced within 360 days from the date of such permit or If the building or woric authortzed by such permit is suspended or abandoned at any time after
the work ls commenced for a period of 180 days (A829l3).
APPLICANT SIGNATURE: _-?/1r,____,~_4_ .. c-6 ______ Q;::.,..4.-..Z::.-_______ DATE:_, ___ ?_-:,_-_2D __
/ 7
1635 Faraday Ave Carlsbad, CA 92008
B-1
Ph: 760-602-2719 Fax: 760-602-8558
Page 2 of 2
Email: Bullding@carlsbadca.gov
Rev. 03/20
PERMIT INSPECTION HISTORY for (CBC2020-0337)
Permit Type: BLDG-Commercial
Work Class: Tenant Improvement
Status: Closed -Finaled
Application Date: 09/04/2020 Owner: REGENCY BRESSI LLC
Issue Date: 11/04/2020 Subdivision:
Expiration Date: 10/12/2021
IVR Number: 28498
Address: 2641 GATEWAY RD, # 101
CARLSBAD, CA 92009-1754
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector Reinspection Inspection
Status
03/1912021 03/19/2021 BLDG-44 153156-2021 Partial Pass Chris Renfro Reinspectlon Incomplete
Rough/Ducts/Dampers
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Smoke duct leak test by 3rd party Verified Yes
and received report. First layer of fire
wrap inspected.
04/0812021 04/08/2021 BLDG-Final Inspection 154524-2021 Partial Pass Chris Renfro Reinspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Pre-final inspection walk, fire final pending. No
Exit sign and egress lighting OK. Need final
test and balance report, title #24, and trash
and recycling receipt paperwork.
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
04/1212021 04/1212021 BLDG-44 154780-2021 Passed Chris Renfro Complete
Rough/Ducts/Dampers
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Smoke duct leak test by 3rd party Verified Yes
and received . 2nd layer Fire wrap ok.
04/21/2021 04/21/2021 BLDG-Flnal Inspection 155564-2021 Passed Tim Kersch Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Pre-final inspection walk, fire final pending. Yes
Exit sign and egress lighting OK. Need final
test and balance report, title #24, and trash
and recycling receipt paperwork.
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Flnal Yes
BLDG-Electrical Final Yes
Wednesday, April 21, 2021 Page 3 of 3
PERMIT INSPECTION HISTORY for (CBC2020-0337)
Permit Type: BLDG-Commercial Application Date: 09/04/2020 Owner: REGENCY BRESSI LLC
Work Class: Tenant Improvement Issue Date: 11/04/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 10/12/2021 Address: 2641 GATEWAY RD, # 101
IVR Number: 28498 CARLSBAD, CA 92009-1754
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Relnspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Duels-Dampers
02/05/2021 02/05/2021 BLDG-17 Interior 149934-2021 Passed Chris Renfro Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
03/05/2021 03/05/2021 BLDG-33 Service 152040-2021 Passed Tim Kersch Complete
Change/Upgrade
Checklist Item COMMENTS Passed
BLDG-Building Deficiency New panel as per revised plan. SDG&E Yes
meter release for new A meter
BLDG-Electric Meter 152039-2021 Passed Tim Kench Complete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
03/15/2021 03/15/2021 BLDG-23 152772-2021 Passed Chris Renfro Complete
Gas/Test/Repairs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-44 152680-2021 Failed Chris Renfro Reinspectlon Incomplete
Rough/Ducts/Dampers
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready, need smoke duct leak test by No
3rd party
03118/2021 03/18/2021 BLDG-85 T-Bar, Celling 153003-2021 Partial Pass Chris Renfro Relnspection Incomplete
Grids, Overhead
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topoul Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
Wednesday, Aprll 21, 2021 Page2 of 3
-----•·····-------
Building Permit Inspection History Finaled
Ccityof
Carlsbad
PERMIT INSPECTION HISTORY for (CBC2020-0337)
Permit Type: BLDG-Commercial Application Date: 09/04/2020 Owner: REGENCY BRESSI LLC
Work Class: Tenant Improvement Issue Date: 11/04/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 10/12/2021 Address: 2641 GATEWAY RD, # 101
IVR Number: 28498 CARLSBAD, CA 92009-1754
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
12/29/2020 12/28/2020 BLDG-81 Underground 147024-2020 Passed Chris Renfro Incomplete
Combo(11, 12,21,31)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-11 Foundation-Fig-Piers No
(Rebar)
BLDG-12 Steel-Bond Beam No
BLDG-21 Yes
Underground-Underfloor
Plumbing
BLDG-31 Yes
Underground-Conduit Wiring
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-11 Foundation-Fig-Piers No
(Rebar)
BLDG-12 Steel-Bond Beam No
BLDG-21 Yes
Underground-Underfloor
Plumbing
BLDG-31 Yes
Underground-Conduit Wiring
01/27/2021 01/27/2021 BLDG-84 Rough 149264-2021 Partlal Pass Chris Renfro Relnspectlon Incomplete
Comb0(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Rough combo on hard lids only No
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
02/01/2021 02/01/2021 BLDG-84 Rough 149531-2021 Passed Chris Renfro Complete
Combo(14,24,34,44)
Wednesday, Aprll 21, 2021 Page 1 of 3
_____ , ___ . ·• ...... ,. ...
DATE: SEPT.24,2020
JURISDICTION: Carlsbad
PLAN CHECK#.: CBC2020-0337
✓. EsG1I
A SAFEtiuilt Cornpa;·ty
SET: II
PROJECT ADDRESS: 2641 Gateway Rd.
PROJECT NAME: Panda Express Restaurant T.I.
□ APPLICANT
□ JURIS.
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person. i
<
D The applicant's copy of the check list has been sent to:
Miguel Topete
~ EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Miguel To~e e Telephone#: 626-288-6898
Date contacted: (by· ) Email: miguel@garywang.com
Mail Telephone Fax In erson
0 REMARKS:
By: Steven Miller
EsGil
Enclosures:
10/19
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858} 560-1468 ♦ fax (858) 560-1576
-~----~ ....... ··--··· .. ,,. . ........ ~---··-----•' ···•···-•----
DATE: SEPT.23,2020
JURISDICTION: Carlsbad
✓• EsG1I
A SAFEbu!lt'Company
PLAN CHECK#.: CBC2020-0337
PROJECT ADDRESS: 2641 Gateway Rd.
SET: I
PROJECT NAME: Panda Express Restaurant T.I.
□ APPLICANT
□ JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Miguel Topete
D EsGil staff did not advise the applicant that the plan check has been completed.
~ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Miguel Topete Telephone#: 626-288-6898
Date contacted: (by: ) Email: miguel@garywang.com
Mail Telephone
0 REMARKS:
By: Steven Miller
EsGil
Fax In Person
Enclosures:
9/23
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
_________ ..
GENERAL PLAN CORRECTION LIST
JURISDICTION: Carlsbad
PROJECT ADDRESS: 2641 Gateway Rd.
DATE PLAN RECEIVED BY
ESGIL: 9/9/20
REVIEWED BY: Steven Miller
FOREWORD · (PLEASE READ):
PLAN CHECK#.: CBC2020-0337
DATE REVIEW COMPLETED:
SEPT.23,2020
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. The approval of
the plans does not permit the violation of any state, county or city law.
• Please make all corrections and submit two new complete sets of prints to:
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
□ Yes □ No
NOTICE: CITY AND ESGIL'S HOURS OF OPERATION ARE AFFECTED BY THE
CURRENT COVID-19 EPIDEMIC. PLAN REVIEWER MAY NOT BE AVAILABLE TO
ANSWER QUESTIONS BY PHONE, BUT MAY BE REACHED BY E-MAIL AT
stmiller@esgil.com . (858) 225-2775
GENERAL
1. Please make all corrections and submit two new complete sets of prints, to:
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one of
two ways: ·
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700.
The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire
Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake
Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of
plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments.
2. Plans may be submitted in electronic format, subject to the jurisdiction's approval. If so,
they must have restrictions removed from the security settings. Electronic plans with
restrictions to markups, printing, or stamping will not be approved.
3. A reminder that due to Covid-19, the City will not permit counter corrections. Please
make sure all the items are satisfied; otherwise, another round of corrections will be
necessary.
PLANS
4. Provide the names, addresses and telephone numbers of the owner and the responsible
design professionals on the Title Sheet. Sec. 107.2.
5. Please provide the CAP B50 Climate Action Plan for this project.
6. Please provide the B55 form to the title sheet.
7. Please update the Building Code Data as a Restaurant is an A2 occupancy. Or provide
documentation as to why you consider a Panda Express a B occupancy Please see
303.3 and 304.1 of the 2019 CBC.
DISABLED ACCESS REVIEW LIST
DEPARTMENT OF STATE ARCHITECT
TITLE 24
The following disabled access items are taken from the 2016 edition of California Building
Code, Title 24. Per Section 1.9.1, all publicly and privately funded public accommodations
and commercial facilities shall be accessible to persons with disabilities.
8. Sales and service counters shall have a portion of the counter which is at least 36" in
length with a maximum height of 34 inches. Section 11 B-904.4. Please indicate on the
plans the location of this area.
ADDITIONAL
9. Please see the P/M Comments below.
10. To speed up the review process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number, calculation
page, etc.
11. Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and
where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate: □ Yes □ No
12. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208,
San Diego, California 92123; telephone number of 858/560-1468, to perform the plan
review for your project. If you have any questions regarding these plan review items,
please contact Steven Miller at Esgil. Thank you.
PLUMBING AND MECHANICAL COMMENTS
PLAN REVIEWER: Connor Reuss SET: I
PLUMBING (2019 CALIFORNIA PLUMBING CODE)
1. Please provide a trap primer to the kitchen trench drain upon next submittal. CPC 1007.0.
2. Keynote #22 (near the water manifolds) on sheet P-100 is not specified within the
Plumbing Key Notes. Please correct.
3. Please elaborate on the manifold water supply system sheet P-100. Is this just cold water?
Specify why hot water lines (non-manifolded) is shown. Clearly specify the size of each
manifold line within the plans.
MECHANICAL (2019 CALIFORNIA MECHANICAL CODE)
4. All mechanical ventilated units are required to have at minimum a MERV-13 filter within the
outside air/return air duct. Please specify this within the mechanical schedule. CMC 401
5. Please show the required 42 inches tall "Guards" (guard rails) or building parapets height
where appliances, mechanical equipment, fans, roof hatch openings or other components
that require service are located within 10 feet of a roof edge or open side of a walking
surface. CBC 1015.6/1015.7 & CMC
Note: If you have any questions regarding this Plumbing and Mechanical plan review list
please contact Connor Reuss at creuss@esgil.com. To speed the review process, note
on this list (or a copy) where the corrected items have been addressed on the plans .
. . . -, ... _, _____ _
· [DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Connor Reuss
BUILDING ADDRESS: 2641 Gateway Rd.
BUILDING OCCUPANCY: A2
IBUILDING
PORTION
Tl A2. Resturant
Air Conditioning
Fire Sprinklers
~ AREA I I (Sq.Ft.~
1488
Valuation
MIJtipler
84.72
PLAN CHECK#.: CBC2020-0337
DATE: SEPT.23,2020
Reg.
Mod.
VALUE ($)
95,009
.,__TO_T._~-V-1i..-LU-E--+-----+--------11-------+-----------95,-009 ........ /
Jurisdiction Code CB By Ordinance
1997 UBC Building Permit Fee ------·• 1 ----T ·hrr.r ·, ---
1997 UBC Plan Check Fee
Type of Review:
D Repetitive Fee
..,.j Repeats
Comments:
------·· •···· ------------~---··-----
Complete Review
□ Other
0 Homly
EaGIIFee
_,., --··-
I
□ Structural Only
1-------11Hr. @ * $393.111/
Sheet 1 of 1
PLUMP ENGINEERING INC .
STRUCTURAL CALCULATIONS
Member of The American Institute of Architects
Client:
Project: Panda Express -Carls bad
Location: 2629 Gateway Road, Carlsbad, CA 92009
Building Code: 2019 California Building Code
Plump File No: S.2008026 By: B.A.B. Date: August 11, 2020
Revisions:
These calculations not valid unless signed
and sealed in space above.
914 E. Katella Avenue, Anaheim, CA 92805 (714) 385-1835 Fax (714) 385-1834
ASCE.
/IMERICAN SOCIETY Of CML ENGINEERS
Address:
2629 Gateway Rd
Carlsbad, California
92009
ASCE 7 Hazards Report
Standard: ASCE/SEI 7-16
Risk Category: II
Soil Class: D -Default (see
Section 11.4.3)
Elevation: 408.08 ft (NAVO 88)
Latitude: 33.126705
Longitude: -117.254558
)
C" /j
p,,-,..r,
: -(,. f~j 4,,1,°'
Wind
Results:
Wind Speed:
10-year MRI
25-year MRI
SO-year MRI
100-year MRI
Data Source:
Date Accessed:
96 Vmph
67 Vmph
72 Vmph
77 Vmph
82 Vmph
ASCE/SEI 7-16, Fig. 26.5-18 and Figs. CC.2-1-CC.2-4
Tue Aug 11 2020
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability =
0.00143, MRI = 700 years).
Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2.
Mountainous terrain , gorges, ocean promontories, and special wind regions should be examined for unusual wind
conditions.
https:/ /a see 7hazardtool .onllne/ Page 1 of 3 Tue Aug 11 2020
. , ...
ASCE
,'\MEAICAN SOCIITT Of CIVIL cNGINEffiS
Seismic
Site Soil Class:
Results:
Ss :
S1
Fa :
F,,:
SMs
SM1
D -Default (see Section 11.4.3)
0.942 S01 N/A
0.345 TL : 8
1.2 PGA: 0.41
N/A PGAM: 0.492
1.13 FPGA 1.2
N/A le 1
Sos 0.754 C,, : 1.271
Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8.
Data Accessed: Tue Aug 11 2020
Date Source: USGS Seismic Design Maps
]lttps://asce 7hazardlool .online/ Page 2of 3
---.. --, --. -.... ·····--·-··--·•···------···· •... , ... ----------------·--·--............. -
Tue Aug 11 2020
AMER!GAN SOClrn' Of cr,l ENGINEERS
The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided "as is" and without warranties of
any kind. The location data included herein has been obtained from information develaped, produced, and maintained by third party providers;
or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from
reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability,
currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement,
affiliation, relationship, or sponsorship of such third-party content by or from ASCE.
ASCE does not intend. nor should anyone interpret. the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable lo you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE 7 Hazard Tool.
https :llasce 7hazardtool .online/ Page 3of 3 Tue Aug 11 2020
PLUMP Engineering, Inc.
914 E. Katella Ave.
Anaheim, California 92805
P:714.385.1835 x 113 F:714.385.1834
www.peica.com
LATERAL ANALYSIS: 'HOOD 1 & HOOD 2'
SEISMIC LOAD: 2018 IBC, 2019 CBC. 2020 LABC/LACBC
:::: II Ip :::: 1.00
:::: 1.20 RP :::: 2.5
= 0.94 aP = 1.0
= 1.13 z = 1.0
:::: 0.75 r :::: 1.0
= 1.6S0s1pWp :::: 1.21 WP
:::: 0.4apSoolp(1 +2z/r)/RpWp = 0.36 WP
= 0.3SoolpWp :::: 0.23 WP
ASCE 7-10 EQ. 13.3-2
ASCE 7-10 EQ. 13.3-1
ASCE 7-10 EQ. 13.3-3
Fp(MAX)
FP
Fp(MIN)
Fp = 0.36 WPx 0.7 = 0.25 Wp(ASD)
WEIGHT
FE =
LATERAL ANALYSIS:
LATERAL =
SCREWS =
NO. =
SHEAR =
SHEARIILL =
UNITY =
GRAVITY ANALYSIS:
WEIGHT =
ROD
NO.
Fy
TENSION
TENSIONALL
UNITY =
608 lb
154 lb
154 lb
#12
4
38 lb/ANCHOR
188 lb/ANCHOR
0.20 < 1.00 --, OKI
608 lb
1/2 "4>
4
36 ksi
152 lb/ROD
4241 lb/ROD
0.04 < 1.00 -> OKI
•
PLUMP Engineering, Inc.
914 E. Katella Ave.
Anaheim, California 92805
P:714.385.1835 x 113 F:714.385.1834
www.peica.com
LATERAL ANALYSIS: 'RTU-2'
SEISMIC LOAD: 2018 IBC, 2019 CBC, 2020 LABC/LACBC
RISK = II Ip = 1.00
Fa = 1.20 RP = 6.0
Ss = 0.94 aP = 2.5
SMs = 1.13 z = 1,0
Sos = 0.75 = 1.0
1.21 WP ASCE 7-16 EQ. 13.3-2
0.38 WP ASCE 7-16 EQ. 13.3-1
Fp(MA)()
FP
Fp(MINJ
Fp
=
1.6SoslpWp
0.4apSoolp(1 +2z/r)/RPWP
0.3S001pW" = 0.23 Wp ASCE 7-16 EQ. 13.3-3
= 0.38 0.7 = 0.26 WP (ASD)
WIND LOAD: 2018 IBC, 2019 CBC, 2020 LABC/LACBC
RISK = II EXPOSURE = c
p = q,GCA
q, = 0.00256K,K21KoK0V
h = 25
K, = 0.94 TBL 26.10-1
K,, = 1.00 SEC. 26.8.2
Ko = 0.95 TBL26.6-1
K. = 1.00 TBL26.9-1
V = 96 .. FIG. 26.5-1
ASD = 0.60
q, = 12.64 psf
NON-STRUCTURAL UNIT:
WEIGHT =
HEIGHT =
WIDTH =
LENGTH =
WEIGHT =
OVERTURNING ANALYSIS:
LATERAL =
MoT =
1238 lb
3.42 ft
4.92 ft
7.33 ft
34.34 psf
602 lb
1028 lb-ft
145 lb-ft -+
ASCE 7-16 EQ. 29.4-2
ASCE 7-16 EQ. 26.10-1
L = 89 ft 0.1BL =
B = 63 ft <L 0.18h =
Ai = 25.06 ft'
A, = 36.06 ft'
GC, = 1.90 [FJ SEC. 29.4.1
GC, = 1.50 [Fvl SEC. 29.4.1
Fh = 602 lb(ASD)
Fv = 684 lb(ASD)
ROOF = WOOD
FE = 327 lb
Fw = 602 lb _, WIND GOVERNS!
ANCHORAGE TO RESIST OTI
____________ ...,_..... .... ...,--.-
557 ft
157 ft
PLUMP Engineering, Inc.
914 E. Katella Ave.
Anaheim, California 92805
P:714.385.1835 x 113 F:714.385.1834
www.peica.com
LATERAL ANALYSIS: 'RTU-2'
!,!NITTO ROOF
ANCHORAGE SOS_SCREWS S1ZE 1/4 in
LENGTH 4 1/2 in EMBED = 2.75 in
NO. = 6 Co = 1.6
NO. TEN. = 3
NO.SHEAR = 6
TENSION = 288 lb/ANCHOR
SHEAR = 100 lb/ANCHOR
TENSIONAL, = 757 lb/ANCHOR
SHEARALL == 560 lb/ANCHOR
UNITY == 0.56 < 1.00 _, OKI
PLUMP Engineering, Inc.
914 E. Katella Ave.
Anaheim, California 92805
P:714.385.1835 x 113 F:714.385.1834
www.peica.com
LATERAL ANALYSIS: 'MA-1'
SEISMIC LOAD: 2018 IBC; 2019 CBC, 2020 LABC/LACBC
RISK = II Ip = 1.00
F. = 1.20 RP = · e:o
Ss = 0.94 aP = 2.5
SMs = 1.13 z = 1.0
Sos = 0.75 = 1.0
Fp(MAX) = 1.6SoslpWp = 1.21 WP ASCE 7-16 EQ. 13,3-2
FP = 0.4apSoslp(1 +2zlr)/RPWP = 0.38 WP ASCE 7-16 EQ. 13.3-1
Fp(MIN) = 0.3SoslpWp = 0.23 WP ASCE 7-16 EQ. 13.3-3
Fp = 0.38 Wpx 0.7 = 0.26 WP (ASD)
WIND LOAD: 2018 IBC, 2019 CBC. 2020 LABC/LACBC
RISK = II EXPOSURE = C
p = q.GC,A, ASCE 7-16 EQ. 29.4-2
q. = 0.00256K.KztKdK.,V2 ASCE 7-16 EQ. 26.10-1
h = 25 L = 89 ft 0.1BL =
K. = 0.94 TBL 26.10-1 B = 63 ft <L 0.1Bh =
Kzt = 1.00 SEC. 26.8.2 ~ = 44.97 ft'
Kd = 0.95 TBL 26.6-1 I\ = 29.49 ft'
K. = 1.00 TBL 26.9-1 GC, = 1.90 [Fh] SEC. 2!1.4.1
V = 96 FIG. 26.5-1 GC, = 1.50 IFvl SEC. 29.4.1
ASD = 0.60 Fh = 1080 lb (ASD)
q. = 12.64 psf fv = 559 lb(ASD)
NON-STRUCTURAL UNIT:
WEIGHT = 1695 lb ROOF = WOOD
HEIGHT = 4.45 ft
WIDTH = 2.92 ft FE = 447 lb
LENGTH = 10.11ft fw = 1080 lb .... WINO GOVERNS!
WEIGHT =
OVERTURNING ANALYSIS:
LATERAL
MoT
MRE
=
57.49 psf
1080 lb
2402 lb-fl
668 lb-ft --> ANCHORAGE TO RESIST OT!
., ... .....,. .... -............ ---· .. ···•-----· ·•------------------·
557ft
157 ft
PLUMP Engineering, Inc.
914 E. Katella Ave.
Anaheim, California 92805
P:714.385.1835 X 113 F:714.385.1834
www.peica.com
LATERAL ANALYSIS: 'MA-1'
UNIT TO ROOF
ANCHORAGE = SOS_SCREWS SIZE = 1/4 in
LENGTH = 4 1/2 in EMBED = 2.75 in
NO. = 6 Co = 1.6
NO. TEN. = 3
NO.SHEAR = 6
TENSION = 385 lb/ANCHOR
SHEAR = 180 lb/ANCHOR
TENSIONALL = 757 lb/ANCHOR
SHEAR.._L = 560 lb/ANCHOR
UNITY = D.83 < 1.DD --> OKI
PLUMP Engineering, Inc.
914 E. Katella Ave.
Anaheim, California 92805
P:714.385.1835 x 113 F:714.385.1834
www.peica.com
LATERAL ANALYSIS: 'EF-1, EF-2, & EF-3'
SEISMIC LOAD: 2018 IBC, 2019 CBC, 2020 LABC/LACBC
RISK II IP = 1.00
F. = 1.20 RP 2.5
Ss 0.94 aP = 1.0
SMs = 1.13 z 1.0
Sos = 0.75 = 1.0
Fp (MAX) 1.6S0slpWp = 1.21 WP
Fp = 0.4apSoslp(1 +2z/r)/RPWP 0.36 WP
Fp(MIN) 0.3SoslpWp = 0.23 WP
ASCE 7-16 EQ. 13.3-2
ASCE 7-16 EQ. 13.3-1
ASCE 7-16 EQ. 13,3-3
FP = 0.36 WPx 0.7 0.25 WP (ASD)
WIND LOAD: 2018 IBC, 2019 CBC, 2020 LABC/LACBC
RISK II EXPOSURE = C
p = q,GCA ASCE 7-16 EQ. 29.4-2
q, o.00256K,K21KdK.v2 ASCE 7-16 EQ. 26.10-1
h = 25 L 115 ft 0.1BL
K, 0.94 TBL 26.1D-1 B = 43 ft -<L 0.18h =
K,t = 1.00 SEC. 26.S.2 A., 13.06 ft'
Kd = 0.95 TBL 26.6-1 A, = 14.42 ff
Ke 1.00 TBL 26.9-1 GC, = 1.90 [F,J SEC. 29.4.1
V = 96 FIG. 26.5-1 GC, 1.50 [F,] SEC. 29.4. 1
ASD 0.60 Fh = 314 lb (ASD)
q, = 12.64 psf Fv 273 lb (ASD)
NON-STRUCTURAL UNIT:
WEIGHT = 222 lb ROOF WOOD
HEIGHT = 3.00 ft (MAX.) EXT.HT 1.00 ft
WIDTH = 3.31 ft FE .. 56 lb
LENGTH = 4.35 ft Fw = 314 lb ~ WINO GOVERNS!
WEIGHT =
OVERTURN ING ANALYSIS:
LATERAL
MoT
MRE
=
15.39 psf
314 lb
784 lb-ft
-232 lb-ft ---, ANCHORAGE TO RESIST OT!
500 ft
109 ft
PLUMP Engineering, Inc.
914 E. Katella Ave.
Anaheim, California 92805
P:714.385.1835 x 113 F:714.385.1834
www.peica.com
LATERAL ANALYSIS: 'EF-1, EF-2, & EF-3'
UNIT TO (E) ROOF
ANCHORAGE = sos_SCREWS SIZE 1/4 in
LENGTH = 4 1/2 in EMBEO 2.75 in
NO. 4 Co = 1.6
NO. TEN. = 2
NO. SHEAR 4
TENSION 290 lb/ANCHOR
SHEAR = 78 lb/ANCHOR
TENSIONAL, 757 lb/ANCHOR
SHEARALL 560 lb/ANCHOR
UNITY = 0.52 < 1.00 -OKI
PLUMP Engineering, Inc.
914 E. Katella Ave.
Anaheim, California 92805
P:714.385.1835 x 113 F:714.385.1834
www.peica.com
LATERAL ANALYSIS: 'CONDENSER RACK'
SEISMIC LOAD: 2018 IBC, 2019 CBC, 2020 LABC/LACBC
RISK II IP = 1.00
F. = 1.20 RP 3.0
Ss = 0.94 ap = 2.5
SMs 1.13 z = 1.0
Sos = 0.75 r 1.0
Fp(MAX) 1.6So81PWP = 1.21 WP
FP = 0.4aPS081p(1 +2z/r)/RPWP = 0.75 WP
Fp{MIN) = 0.3SoslpWp 0.23 WP
ASCE 7-16 EQ. 13.3-2
ASCE 7-16 EQ. 13.3-1
ASCE 7-16 EQ. 13.3-3
Fp = 0.75 WP X 0.7 = 0.53 WP (ASD)
WIND LOAD: 2018 IBC, 2019 CBC, 2020 LABC/LACBC
RISK = II EXPOSURE C
p qzGC,A, ASCE 7-16 EQ. 29.4-2
qz = o. 00256KzKztKd K. V2 ASCE 7-16 EQ. 26.10-1
h = 25 L = 115 ft 0.1BL =
Kz = 0.94 TBL 26.10-1 B = 43 ft <L 0.1Bh =
K,, = 1.00 SEC. 26.8.2 A., 20.01 ff
Kd = 0.95 TBL 26.6-1 A. = 16.12 ff
K. = 1.00 TBL 26.9-1 GC, = 1.90 [Fhl SEC. 29.4.1
V = 94. FIG. 26.5-1 GC, = 1.50 [F,] SEC. 29.4.1
ASD = 0.60 Fh 461 lb (ASD)
q, = 12.12 psf Fv = 293 lb(ASD)
NON-STRUCTURAL UNIT:
WEIGHT = 623 lb ROOF WOOD
HEIGHT = 3.00 ft (MAX.) EXT.HT 0.00 ft
WIDTH = 2A2 ft Fe = 329 lb
LENGTH 6.67 ft Fw = 461 lb -WIND GOVERNS!
WEIGHT
OVERTURNING ANALYSIS:
LATERAL
=
38.64 psf
461 lb
691 lb-ft
340 lb-ft -> ANCHORAGE TO RESIST OTI
500 ft
109 ft
PLUMP Engineering, Inc.
914 E. Katella Ave.
Anaheim, California 92805
P:714.385.1835 x 113 F:714.385.1834
www .peica.com
LATERAL ANALYSIS: 'CONDENSER RACK'
UN(I TO (El ROQF
ANCHORAGE = SDS_SCREWS SIZE = 1/4 in
LENGTH = 4 1/2 in EMBED = 2.75 in
NO. = 12 Co = 1.6
NO. TEN. = 6
NO.SHEAR = 12
TENSION = 73 lb/ANCHOR
SHEAR = 38 lb/ANCHOR
TENSIONALL = 757 lb/ANCHOR
SHEARALL = 560 lb(ANCHOR
UNITY = 0.17 < 1.00 --OKI
------.. --,. ,. ·~ ....... ,.-~-----·-
•
PLUMP Engineering, Inc.
914 E. Katella Ave.
Anaheim, California 92805
P:714.385.1835 x 113 F:714.385.1834
www.peica.com
LIVE LOAD REDUCTION
Roof Live Load:
GLBGIRDER
Lo = 20.0 psf
L = 25.0 ft
T = 30.0 ft
Ar = 750 ft'
F ;:: 0.25 in per ft rise
R1 = Ar <;:: 200
R1 = 0.45 200 <AT< 600
R1 = 0.6 Ar >= 600
R2 = 1 F <= 4
R2 = 1.19 4 <F< 12
R2 = 0.6 F >= 12
L = 12.0 psf ASCE 7-16 .4;s-1
_______ _,, .. ..,,..,,., _____ . -,.,, __ ................ _ ~-.. .
ESR-1991 Most Widely Accepted and Trusted Page 5 of 10
TABLE 2A-SSI JOIST REFERENCE DESIGN VALUES'·•·•
2112" 211," 1•1 ... t]l.t'
OVERALL MOMENT1'1 SHEAR BEARING BEARING BEARING BEARING El K DESCRIPTION DEPTH (ft-lbf} {lbf) WITH WITHOUT WITH WITHOUT (lbf-in') (lbf-inlin) (inches) STIFFENERS STIFFENERS STIFFENERS STIFFENERS
(lbf) {lbf) (lbf) (lbf)
9.5 4,590 1,500 1,500 1,500 1,500 1,500 260 5.39
11.875 5,945 1,760 1,760 1,600 1,760 1,600 487 6.60
SSI 32M 12 6,020 1,775 1,775 1,600 1,775 1,600 499 6.67
21/," X 1'/2 -11..._ -_ 7_,.:160_ 1,995 1,995 1,600 1,995 1,600 717 7.71
MSR Flange u, ~ ~,3Ull \ 2,215 2,215 1,600 2,215 1,600 979 8.77
318 -inch 8 9,445 2,440 2,440 1,600 2.440 1,600 1,287 9.84
OS8Web D 10,585 f 2,660 2,660 1,600 2,660 1,600 1,643 10.91
2 J 11,130 2,880 2,880 1,600 N/A N/A 2,048 11.99
24 --1"2;870" 3,100 3,100 1,600 N/A NIA 2,504 13.06
26 13,970 3,320 3,320 1,600 NIA NIA 3,013 14.14
9.5 6,515 1,500 1,500 1,500 1.500 1,500 360 5.47
11.875 8,445 1,760 1,760 1,600 1,760 1,600 671 6.69
SSl42M 12 8,545 1,775 1,775 1,600 1,775 1,600 688 6.75
31/2" X 111," 14 10,170 1,995 1,995 1,600 1,995 1,600 984 7.81
MSR Flange 16 11.790 2.215 2,215 1,600 2,215 1,600 1,338 8.88
318 -inch 18 13.415 2.440 2,440 1,600 2.440 1,600 1,751 9.95
OSBWeb 20 15,035 2,660 2,660 1,600 2,660 1,600 2,226 11.04
22 16,660 2,BB0 2,880 1,600 NIA NIA 2,763 12.12
24 18,285 3,100 3,100 1,600 NIA NIA 3,366 13.20
26 19,850 3,320 3,320 1,600 NIA N/A 4,034 14.29
9.5 7,785 1,500 1,500 1,500 1,500 1,500 413 5.47
11.875 10,090 1,760 1,760 1,600 1,760 1,600 702 6.69
SSl42MH 12 10,210 1,775 1,775 1,600 1,775 1,600 719 6.75
31/i X 1 'I," 14 12,150 1,995 1,995 1,600 1,995 1,600 1,029 7.81
MSR Flange 16 14,090 2,215 2,215 1,600 2,215 1,600 1,399 8.88
318 -inch 18 16,030 2,440 2,440 1,600 2,440 1,600 1,831 9.95
OSBWeb 20 17,965 2,660 2,660 1,600 2,660 1,600 2,327 11.04
22 19,905 2.880 2,880 1,600 NIA NIA 2,889 12.12
24 21,845 3,100 3,100 1,600 NIA NIA 3,518 13.20
26 23,720 3,320 3,320 1,600 N/A NIA 4,218 14.29
9.5 4,525 1,875 1,875 1,735 1,875 1,600 260 7.65
11.875 5,860 2,115 2,115 1,735 2,065 1,735 443 9.39
14 7,055 2,330 2,330 1,750 2,275 1,750 652 10.99
SSI 32MX 16 8,175 2,530 2,530 1,750 2,475 1,750 890 12.50
2'1,"x 1'1i 18 9,300 2,735 2,735 1,590 2,675 1,590 1,170 14.02
MSRFlange 20 10,425 2,935 2,935 1,590 2690 1,590 1,494 15.55 'I,-Inch 22 11,545 3,315 3,315 N/A 2690 NIA 1,862 17.06
OS8WE8 24 12,670 3,335 3,335 NIA 2690 NIA 2.276 18.62
26 13,755 3,540 3,540 NIA 2690 NIA 2,739 20.15
28 14,775 3,740 3,740 NIA N/A N/A 3,252 21.66
30 15,790 3,940 3845 NIA NIA NIA 3,816 23.21
9.5 4,525 1,300 1,300 260 7.65
11.675 5,860 1,525 1,525 443 9.39
32MXT 14 7,055 1,725 1,725 652 10.99
2'/z X 1112" 16 8,175 1,915 1,915 890 12.50
MSR Flange 18 9,300 2,105 2,105 N/A NIA NIA 1,170 14.02
15132-inch 20 10,425 2,290 2,290 1,494 15.55
OSBWeb 22 11,545 2,484 2,484 1,862 17.0B
24 12,670 2,670 2,670 2,276 18.62
26 13,755 2,860 2,860 2,739 20.15
9.5 6,450 1,735 1,735 1,735 1,735 1,735 360 7.79
11.875 8,355 2,060 2,060 1,735 2,065 1,735 610 9.54
14 10,060 2,350 2,350 1,750 2,275 1,750 895 11.15
SSl42MX 16 11,665 2,620 2,620 1,750 2.475 1,750 1,216 12.68 3112 x 1112" 18 13,270 2,B95 2,895 1,590 2,675 1,590 1,592 14.22
MSR Flange 20 14,875 3,165 3,165 1,590 2,875 1,590 2,023 15.77
112 -Inch 22 16,480 3,440 3,440 NIA 3,075 N/A 2,512 17.32
OSBWEB 24 18,085 3,710 3,710 NIA 3,275 N/A 3,060 18.87
26 19,635 3,985 3,985 NIA 3,475 NIA 3,668 20.42
28 21,090 4,255 4,255 N/A N/A N/A 4,338 21.97
30 22,540 4,530 4,530 NIA N/A N/A 5,072 23.53
9.5 6,257 1,300 1,300 298 7.79
11.875 8,104 1,525 1,525 509 9.54
42MXT 14 9,758 1,725 1,725 750 11.15
31/2" X 1112" 16 11,315 1,915 1,915 1,024 12.68
MSR Flange 18 12,872 2,105 2,105 NIA NIA NIA 1,346 14.22
15/32-inch 20 14,429 2,290 2,290 1,716 15.77
OSBWeb 22 15,986 2.484 2,484 2,141 17.32
24 17,542 2,670 2,670 2,618 18.87
26 19,046 2,860 2,860 3,150 20.42
For SI: 1 inch = 25.4 mm, 1ft-lbf = 1.356 N-m, 1 lbf-in2 = 2.87 kN-mm\ 1 in-lbf/in = 4.45 N-mmlmm, 1 lbf = 4.45N.
'The reference design moment and shear values are for normal duration of load. The appropriate code must be reviewed for duration of load
factor adjustments to reference design moment and shear values. Allowable end reaction values are not permitted to be increased for other
durations of load.
2Refer to Table 1 for web stiffener detail.
3Moment capacity of the I-joists, which must not be increased by any code allowed repetitive member use factor.
--------··•·•·······•·~-·-··-·--------......
Plump Engineering, Inc.
914 E. Katella Ave.
Anahiem, CA 92805
Phone: 714-385-1835
Project Title: Panda -Carlsbad
Engineer: BAB
Project ID: S.2008026
Project Descr:
j nc Fax: 714-385-1834
•H ............ ., •• ~ .... , www.peica.com
General Beam
Pnnted· 12 AUG 2020, 1 32PM
File: S.2008026 -Panda -·artsbad.ec6
Software copyright ENERCALC, INC. 198l-2020, Bulld:12.20.5.17
DESCRIPTION: (E) 18" Roof Truss
General Beam Properties
Elastic Modulus 29,000.0 ksi
. . .
Span #1 Span Length = 30.0 ft Area = Moment of Inertia =
0(03095)
Lr 0 .04 ,,..----,,-~-~ .. --. Lr 0 .04 ~-~--'-"'~~~-~
• X
S pan = 30 .0 ft
D(0.339) Lr 0 .04 D(O 11)
~....,-"'-L,._,,_r or·=-04.:..,.,.---.
• X
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.0150 ksf, Tributary Width = 2.0 ft, (Roof Dead)
Point Load : D = 0.3095 k@8.333 ft, (RTU-2 (1238#/4))
Point Load : D = 0.3390 k@ 19.0 ft, (MUA (1695#/5))
Point Load : D = 0.110 k@25.0 ft, (CU-2 (220#/2))
Uniform Load : Lr = 0.020 ksf, Extent = 0.0 -» 4.833 ft, Tributary Width= 2.0 ft, (Roof Live)
Uniform Load : Lr = 0.020 ksf, Extent = 12.250 -» 17.167 ft, Tributary Width = 2.0 ft, (Roof Live)
Uniform Load : Lr = 0.020 ksf, Extent = 20.667 -» 23.750 ft, Tributary Width = 2.0 ft, (Roof Live)
Uniform Load : Lr = 0.020 ksf, Extent = 26.250 -» 30.0 ft, Tributary Width = 2.0 ft, (Roof Live)
DESIGN SUMMARY
Maximum Bending =
Load Combination
Maximum Shear=
Load Combination
Span # where maximum occurs
Location of maximum on span
9.049 k-ft
+O+Lr
Span# 1
16.050 ft
Span # where maximum occurs
Location of maximum on span
Maximum Deflection Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
0.120 in
0.002 in
0.509 in
0.004 in
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios
Segment Length Span# M V Mmax+
Overall MAXimum Envelope
Dsgn. L = 30.00 ft 9.05
D Only
Dsgn. L = 30.00 ft 6.86
...O+Lr
Dsgn. L = 30.00 ft 9.05
+D...0.750Lr
Dsgn. L = 30.00 ft 8.50
...0.60D
Dsgn. L = 30.00 ft 4.11
3001
193255
706
97854
Summary of Momeni Values
Mmax-Ma-Max Mnx
9.05
6.86
9.05
8.50
4.11
(k-ft)
Mnx/Omega Cb Rm
1.186 k
+O+Lr
Span# 1
30.000 ft
Shear Values (k)
Va Max Vnx Vnx/Omega
1.19
0.84
1.19
1.10
0.51
Plump Engineering, Inc.
914 E. Katella Ave.
Anahiem, CA 92805
Phone: 714-385-1835
inc Fax: 714-385-1834
•u-"1'""'"'''ii, ........ t" www.peica.com
@ eneral Beam ,.,, '
DESCRIPTION: (E) 18" Roof Truss
Overall Maximum Deflections
Load Combination
-t-O+Lr
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
,-.,
,J ,._
I ::I. V
,J
C II)
E 0 !
D Only
-t-O+Lr
-t-0-+-0.750Lr
-+-0.60D
Lr Only
9,2
6,9
4,6
2.3
MEMBER·-·»
2,85
Span
1
Support 1
1.136
0.816
1.136
1.056
0.490
0.319
5,85
Project Title: Panda -Carlsbad
Engineer: BAB
Project ID S.2008026
Project Descr:
Printed 12 AUG 2020, 1:32PM
1 e: .2008026 -Panoa -ar1sbad.ec6
Software copyright ENERCALC, INC. 1983-2020, Build: 12.20.5.17 . . .
Max. ' -" Defl Location in Span Load Combination Max. "+' Defl Location in Span
0.5094 15.150
Support 2
1.186
0.842
1.186
1.100
0.505
0.344
8~5
Support notation : Far left is #1
11.85 14,85 17,85
~stance (ft)
I DO•ly I +Dtl, I +D+D.mt, I +HOD
0.0000 0.000
Values in KIPS
20,85 26,85 29.85
..
DESCRIPTION: (E) 18" RoofTruss
12
0,6
,-..
:1. MEMBER--·» V
I.
IJ
L\ .r.
lfl
-0,6
-1.2
-0,13
c -0,26
V
II.. a)
0
-0.39
-0.52
~
-~ ~ --~---r---__
225 5,85
2.70 5.55
---
--~
8,85
8,40
Project Title: Panda -Carlsbad
Engineer: BAB
Project ID S.2008026
Project Descr:
Software copyright ENERCALC, INC. 1983-2020, Bulld:12.20.5.17 . . .
~ ~-...... .. ==-...
..... ~ -~ -~ ........... -~ -"""""'-............ ... _ ---"' ~
-~
1125 14,85 17,85 20,85 23.85 29,85
~stanceW)
I DO•ly I +D+l• I +D+0.m t, I +0.60D
11.25 14,10 16,95 19,80 ms 25.50 28.35
Distance (rt)
I DO•ly I +D+l1 I +D+rn0l1 I +0.600 I l1Only
. ..
Plump Engineering, Inc.
914 E. Katella Ave.
Anahiem, CA 92805
Phone: 714-385-1835
inc Fax: 714-385-1834
n 1o•l't1tA.f"U•••·• .. t www.peica.com
General Beam
1.1 1 ,
DESCRIPTION: (E) 20" Roof Truss
General Beam Properties
Elastic Modulus 29,000.0 ksi
Span #1 Span Length =
D(O r67)
X
Applied Loads
30.0 ft Area =
Project Title: Panda -Carlsbad
Engineer: BAB
Project ID: S.2008026
Project Descr:
Printed 12 AUG 2020, 1.35PM
~~F~ile~: S~.~0~0=25 -Pancfa -Carlsbad.ec6
Software copyright ENERCALC, INC. 1983-2020, Build: 12.20.5.17 . . .
10.0 in'2 Moment of Inertia = 100.0 in'4
D 0 .03 Lr 0 .04
X
Span = 30.0 ft
Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.0150, Lr= 0.020 ksf, Tributary Width = 2.0 ft, (Roof Dead)
Point Load : D = 0.3667 k@ 3.0 ft, (RTU-1 (1100#/3))
DESIGN SUMMARY
Maximum Bending =
Load Combination
Span # where maximum occurs
Location of maximum on span
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
8.434 k-ft
+D+lr
Span# 1
14.550ft
0.253 in
0.004 in
0.480 in
0.002 in
Maximum Shear=
Load Combination
Span # where maximum occurs
Location of maximum on span
1420
89506
749
162370
Maximum Forces & Stresses for Load Combinations
Load Combination
Segment Length
Overall MAXimum Envelope
Dsgn. L = 30.00 fl
D Only
Dsgn. L = 30.00 fl
+0-+lr
Dsgn. L = 30.00 fl
-+0..{).750Lr
Dsgn. L = 30.00 fl
+0.60D
Span#
Dsgn. L = 30.00 fl 1
Overall Maximum Deflections
Load Combination
+0-+lr
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
D Only
+0-+lr
+0+0.750Lr
+0.60D
Lr Only
Max Stress Ratios
M V
Span
1
Support 1
1.380
0.780
1.380
1.230
0.468
0.600
Max.•-• Defl
0.4803
Support 2
1.087
0.487
1.087
0.937
0.292
0.600
Summary of Moment Values (k-11)
Mmax+ Mmax-
8.43
3.95
8.43
7.31
2.37
Location in Span
14.850
Ma-Max Mnx
8.43
3.95
8.43
7.31
2.37
Load Combination
Support notation : Far left is #1
Mme/Omega Cb
1.380 k
+D+lr
Span# 1
0.000 ft
Shear Values (L
Rm Va Max Vnx Vnx/Omega
1.38
0.78
1.38
1.23
0.47
Max."+" Defl
0.0000
Values in KIPS
Location in Span
0.000
Plump Engineering, Inc.
914 E. Katella Ave.
Anahiem, CA 92805
Phone: 714-385-1835
in C Fax: 714-385-1834
·~'"""'""',;t1"1"' ,.,c www.peica.co~m __
General Beam
DESCRIPTION: (E) 20" Roof Truss
,..,
J.J 11,,, I .i, .._,
J.J
C
Q)
E 0 ~
1.4
02
0.1
~ MEMBER···»
Q)
£
lfl
-0.S
-1.1
2.85 5,85
2.85 5,85
8.85
8.85
11.85
Project Title: Panda -Carlsbad
Engineer: BAB
Project ID: S.2008026
Project Descr:
Printed· 12 AUG 2020, 1.35PM
File: ST00l!l!26 -Panda -Carlsbad.ec6
Software copyright ENERCALC, INC. 1983-2020, Bulkl:12.20.5.17 . . -
14,85 17,85 20,85 ms 26,85 29.85
~stance (it)
I D O•ly I tD+l, I tDtWDl, I +D.6DD
11.85 14,85 17,85 20,85 23.85 26,85 29.85
Distance (it)
I DO•ly I tD+l1 I tD+D.mt, I +D.6DD
Plump Engineering, Inc.
914 E. Katella Ave.
Anahiem, CA 92805
Phone: 714-385-1835
inc Fax: 714-385-1 834
l'\l<fll. .... ,u .. Ult•ll"Jf WWW,Reica.co_m __
DESCRIPTION: (E) 20" Roof Truss
-0,12
'2 .0,24 v
u...
V
Cl
-0.37
,0.49
2,70 5.55 8,40 11.25
Project Title: Panda -Carlsbad
Engineer: BAB
Project ID: S.2008026
Project Descr:
Printed: 12 AUG 2020, 1 35PM
F11e: S.200'8026 -Pan a -Cars -ad.ec6
Software copyright ENERCALC, INC. 1983-2020, Bulld:12.20.5.17 .. .... ..
14.10 16,15 19,80 ms 25.50 28.35
Distance (it)
I D Only I +D+l• I +D+D.ml, I +0.600 I l• O•ly
Plump Engineering, Inc.
914 E. Katella Ave.
Anahiem, CA 92805
Phone: 714-385-1835
Project Title: Panda -Carlsbad
Engineer: BAB
Project ID: S.2008026
Project Descr:
i nc Fax 714-385-1834
•0 •·'"1""'"., •• ,.. -.. e WNW. eica.com
Wood Beam Software copyright ENERCALC, INC. 1983-2020, Build: 12.20.5.17
1 ,1 1 ,
DESCRIPTION: (E) GLB
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
-. .
Analysis Method: Allowable Stress Design
Load Combination ASCE 7-16
Fb +
Fb -
Fc-Prll
2,400.0 psi
1,850.0 psi
1,650.0 psi
E : Modulus of Elasticity
Wood Species : DF/DF Fe -Perp
Wood Grade : 24F-V4 Fv
Ft
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
D(O 623)
D{0.45) Lr(0.36)
V V V
( ) 5. 125x21
Span = 25 .0 ft
650.0 psi
265.0 psi
1,100.0psi
[J()t12]JI)
V
Ebend-xx 1,800.0 ksi
Eminbend -xx 950. 0 ksi
Ebend-yy 1,600.0 ksi
Eminbend -yy 850.0 ksi
Density 31.210 pcf
D(0H8)
V
~
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Uniform Load : D = 0.0150, Lr= 0.0120 ksf, Tributary Width = 30.0 ft, (Roof Load)
Point Load : D = 1.10 k@ 15.0 ft, (RTU1 (1100#))
Point Load : D = 1.238 k@ 15.0 ft, (RTU-2 (1238#))
Point Load : D = 0.6230 k @ 5.50 ft, (CU Rack (623#))
Point Load : D = 0.5190 k @23.50 ft, (Hood -1 (519#))
Point Load : D = 0.6080 k @ 23.50 ft, (Hood -2 (608#))
Point Load : D = 0.1110 k@ 23.50 ft, (EF -1 (222#/2))
Point Load : D = 0.1110 k @ 23.50 ft, (EF -2 (222#/2))
DESIGN SUMMARY
Maximum Bending Stress Ratio
Section used for this span
0.914: 1
5.125x21
2,547.95psi
2,787.70psi
Maximum Shear Stress Ratio
Section used for this span
Load Combination
Location of maximum on span
Span# where maximum occurs
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
+O+lr
13.595ft
Span# 1
0.447 in Ratio=
0.000 in Ratio=
1.260 in Ratio=
0.000 in Ratio=
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios
Segment Length Span# M V Cd C FN Ci Cr Cm
D Only
Length = 25.0 ft 0.829 0.386 0.90 0.929 1.00 1.00 1.00
+D+Lr 0.929 1.00 1.00 1.00
Length = 25.0 ft 0.914 0.441 1.25 0.929 1.00 1.00 1.00
+D+0.750Lr 0.929 1.00 1.00 1.00
Load Combination
Location of maximum on span
Span # where maximum occurs
671 >=360
0 <360
238 >=180
0<180
Ct CL
1.00 1.00
1.00 1.00
1.00 1.00
1.00 1.00
Moment Values
M lb
52.21 1,663.23
79.98 2,547.95
F'b
0.00
2007.14
0.00
2787.70
0.00
Design OK
0.441 : 1
5.125x21
145.98 psi
331 .25 psi
+D+lr
0.000ft
Span# 1
Shear Values
V fv
0.00 0.00
F'v
0.00
6.60 91.96 238.50
0.00 0.00 0.00
10.47 145.98 331.25
0.00 0.00 0.00
Plump Engineering, Inc.
914 E. Katella Ave.
Anahiem, CA 92805
Phone: 714-385-1835
inc Fax: 714-385-1834
.. ,~cu .. u,uu, .. c. www.peica.com
Wood Beam
1.11 ,
DESCRIPTION: (E) GLB
Load Combination
Segment Length
Length = 25.0 ft
+0.60D
Max Stress Ratios
Span#
1
M
0.834
V
0.400
Length = 25.0 ft 1 0.280 0.130
Overall Maximum Deflections
Load Combination
..0-+lr
Vertical Reactions
Load Combination
Overall MAXimum
,-..
"' "-I ::i.
V
"' C
I)
E 0 r
Overall MINimum
D Only
+D-+lr
+D+0.750Lr
+0.60D
Lr Only
2.37
Span
1
424
Cd C FN Ci Cr Cm
1.25 0.929 1.00 1.00 1.00
0.929 1.00 1.00 1.00
1.60 0.929 1.00 1.00 1.00
Project Title: Panda -Carlsbad
Engineer: BAB
Project ID: S.2008026
Project Descr:
Printed 12 AUG 2020, 5 02PM
Hle:S.2008026 -Panda -Carts ad.eco
Software copyright ENERCALC, INC. 1983-2020, Bulld:12.20.5.17 . -.
Moment Values Shear Values
Ct CL M fb F'b V fv F'v
1.00 1.00 73.01 2,325.76 2787.70 9.51 132.47 331.25
1.00 1.00 0.00 0.00 0.00 0.00
1.00 1.00 31.33 997.94 3568.25 3.96 55.18 424.00
Max. " -" Defl Location in Span Load Combination Max. "+" Defl Location in Span
1.2600
Support 1
11.919
4.500
7.419
11.919
10.794
4.451
4.500
7.30
12.682
Support notation : Far left is #1
Support 2
13.224
4.500
8.724
13.224
12.099
5.235
4,500
916 12,23
Distance (it)
14~9
I DOnly I +D+li I +D+WDl1 I +0.6DD
0.0000 0.000
Values in KIPS
17.15 19.62 22.08 24.54
Plump Engineering, Inc.
914 E. Katella Ave.
Anahiem, CA 92805
Phone: 714-385-1835
inc Fax: 714-385-1834
• 11o•••"4i•tl••••• .. c www.peica.com
Wood Beam
1.11 ,
DESCRIPTION: (E) GLB
12
6 MEMB~R-.. »
l..
(J
Q) .r. lf1
II.
4)
Q
.]
,13
237
2.37
424 7J)
4.84 7.30
Project Title: Panda -Carlsbad
Engineer: BAB
Project ID: S.2008026
Project Descr:
Pnnted t2 AUG 2020 5 02PM
ile: S".2008026 -Panda -Carlsbad.ec6
Software copyright ENERCALC, INC. 1983-2020, Build: 12.20.5.17
12.23
Distance (ft)
I DO•~ I +Dtl1 I +D+0.mli I +0.60O
12.23
Distance (ft)
14.t9
14.69
I DO•ly I +Dtl1 I tO+W0li I +0.60D I l,O•ly
17,15
17,15
. . -
19,&2 22,08 24,54
19,G2 22.08 24.54
.Y I
) _,,, '-.. . ' Z X
Envelope Only Solution
Plump Engineering, Inc. j
BAB
_l_
r Aug 12, 2020 at 2:29 PM j
S.2008026 -Soffit.r3d
.v
. z ·x
10
Envelope Only Solution
,; Plump Engineering, Inc.
' .
·BAB I
...
Aug 12, 2020 at 2:29 PM
. S.2008026 -Soffit.r3d
,Y
. Z X
10
Envelope Only Solution
Plump Engineering, Inc,
BAB
...
2
...
'Aug 12, 2020 at 2:30 PM
S.2008026 • Soffitr3d
,Y
Z X
Loads: BLC 1. DL
Envelope Only Solution
10
-Plump Engineering, Inc.
[ sAB
5PSF X 1.33FT
T
' ,;
-.007k/
'
2
Aug 12, 2020 at 2:30 PM
S.2008026 -Soffit.r3d
.Y
" /
z X
Loads: BLC 2, WL
Envelope Only Solution
-.0131</11
I
10
I Plump Engineering, Inc.
BAB
5PSF X 2.67FT
-.013klft
... .,
...
2
Aug 12, 2020 at 2:30 PM
s 2008026 -Soffit.r3d 1 '
.v
z ·x
Member Code Checks Displayed (Enveloped)
1 Envelope Only Solution
i Plump Engineering, Inc. !
;BAB !
.,_ ------..... -,--~-... -,-
Code Check
(Env) I NoCalc
>1.0
.S0-1.0
.7S-.90 1-.... S0-.75
0.-.50
Aug 12, 2020 at 2:31 PM
I S.2008026 -Sofflt.r3d
Company
Designer
Job Number
Model Name
Plump Engineering, Inc.
BAB
S.2008026
PANDA -SOFFIT
(Global) Model Settings
lo· I S f M b C 1soIav ectIons or em er a cs
Max Internal Sections for Member Cales
Include Shear Deformation?
Increase Nailina Caoacitv for Wind?
Include Warpinq?
5
97
I Yes
I Yes
Yes
Trans Load Btwn lntersectina Wood Wall? , Yes
Area Load Mesh (in"2)
Merae Tolerance <in)
P-Delta Analvsis Tolerance
Include P-Delta for Walls?
Automatically Iterate Stiffness for Walls?
Max Iterations for Wall Stiffness
Gravity Acceleration (ft/sec"2)
Wall Mesh Size (in)
. Eiaensolution Converaence Toi. (1 .E-)
Vertical Axis
I Global Member Onentat,on Plane
!Static Solver
Dynamic Solver
Hot Rolled Steel Code
Adiust Stiffness?
RISAConnection Code
Cold Formed Steel Code
Wood Code
Wood Temoerature
Concrete Code
Masonry Code
Aluminum Code
Stainless Steel Code
AdJust Stiffness?
N b f Sh R um ero ear ea,ons
Reqion Soacinq Increment (in)
Biaxial Column Method
Parme Beta Factor (PCA)
Concrete Stress Block
Use Cracked Sections?
Use Cracked Sections Slab?
Bad Framina Warninas?
Unused Force Warninas?
Min 1 Bar Diam. Soacina?
Concrete Rebar Set
Min % Steel for Column
0 Max 1/o Steel for Column
144
I .12
0.50%
Yes
I Yes
13
132 .2
I 24
4
IY xz I Sparse Accelerated
Accelerated Solver
I AISC 15th(360-16):LRFD
I Yes(lterative)
I AISC 15th(360-16): LRFD
IAISI S100-16: LRFD
AWC NDS-15· ASD
I < 100F
ACI 318-14
I TMS 402-16: Strenath
AA ADM 1-15: LRFD -Buildinq
IAISC 14th(360-10): ASD
Yes(lterat,ve)
4
14
Exact lntearation
I .65
I Rectanaular
I Yes
, Yes
I No
Yes
!No
REBAR SET ASTMA615
11
I 8
RISA-3O Version 17.0.4 (J:\RISA-3O\2020\S.2008026 -Soffit.r3d)
I
I
I
I
I
I
I
I
I
Aug 12, 2020
5:03 PM
Checked By: GMP
Page 1
Company
Designer
Job Number
Model Name
Plump Engineering, Inc.
BAB
S.2008026
PANDA· SOFFIT
(Global) Model Settings, Continued
Seismic Code
!Seismic Base Elevation (ft)
Add Base Wei ht?
CtX
CtZ IT X (sec)
T Z (sec)
Ct Exp. Z
sos
S1
TL (sec)
!Risk Cat
I Drift Cat
!Om Z
RhoX
Basic Load Cases
ASCE 7-1 0 I Not Entered
Yes
.02
.02 I Not Entered
, Not Entered
.75
5
I or II
Other
1
Aug 12, 2020
5:03 PM
Checked By: GMP
BLC Description
D_L
Category
DL
X Grav ... Y Grav ... Z Grav... Joint Point Distrib ... Area(M .. Surface(Plate/ ... 8 T 1
2 _j__ -1 r--r-----r~2 1
Load Combinations
Description
DL
Solve PDeltaSR. .. BLC Fact... BLC F ... BLC Fa ... BLC F ... BLC F ... BLC Fa ... BLC__F ... BLCF ... BLCF ........ . ~ Yes -. 1 DL J 1 I I 1 -I i I I j ' I 1 -DL+WL Yes I i DL 1 I WL 11 I I I i I I I I I
Member Distributed Loads (BLC 1 : DL}
Member Label Direction Start Magnitud~(k/ft,F,ksf] End Magnitude[k/ft,F,ksf] Start Location[ft, ... End Location[ft, %)
0 0 t----'~,---~M=4~---,---~Y_------,---,----~--=0~7~---,-------'-~007
M.=5 __ ___._ __ y -f----_-.00_L_ ~_-.0=0_._7 __ ---+-0 _.0"'-----
M3 Y -.007 -.007
M1 Y -.007 -.007
M2 Y -007 -.007
2 Y -.007 -.007
M2 Y -.007 -.007
M2 Y -007 -.007
Member Distributed Loads (BLC 2 : WLJ
1
2
Member Lab~I
M3
M1
RISA-3O Version 17.0.4
Direction z z
Start Magnitude(k/ft,F,ksf] r -.013 I -.013
End Magnitude(k/ft,F,ksf]
-.013
-.013
[J :\RISA-3O\2020\S.2008026 -Soffit.r3d]
0 0
0 4
6 8
6 8
6 8
6
Start Location(ft, ... End Location(ft, %) I o o
1 o ! 4 I
Page 2
•
Company
Designer
Job Number
Plump Engineering, Inc.
BAB
S.2008026
Aug 12, 2020
5:03 PM
Checked By: GMP
.. , .. ,,inc Model Name PANDA -SOFFIT
Envelope A/SI S100-16: LRFD Cold Formed Steel Code Checks
1
M.filllber Shape Code ... _ Loc[ft] jLC Shear ·toc[ft] DlLLC phi*Pn[k] phi*Tn[k]f hi_:Mny ... phi*Mnz.fhi*\1phi*V... Cb Eqn
M1 350S162 ... 196 4 2 I .034 4 v 2 1.681 7.663 .197 .53 1.5561.82611.667 H1 .1-27
2 M2 350S162 .. .023 3.958 I 2 .002 14.01 V 1 3.209 7.663 .139 .718 11.5561 .82611.418 H1.1-1 1
3 M3 350S162 .. .067 1.719 2 .019 3.958 V 2 3.209 7.663 I .139 .718 1.55611 .8261.351
-~ 4 M4 350S162 .. .009 2.012 12 .006 11.979 V 1 4.111 7.663 I .225 .69 11.55611 .82612.194 H2-1
5 MS 350S162 .... 036 2 2 .013 2 V12 2.536 7.663 .139 .718 11.5561.8262.603 H1 .1-1
6 M6 350S162 .. ! .076 1.91 I 2 .001 14.472 V 2 ! 3.584 7.663 I .219 .612 11.5561.82611.136H1 .2-1 1
Envelope Member Section Forces
[ _21 r M~1b+er~_s.
2
r ~x Ax~l[I<] f L2~
1
c r Sh~•'1'j-l:ff6~•,fk] 'i To"1;''+i t' ~om 'it ' ~01~
r min O -7 0 I 1 r O -1 0 -1 --0 1 0 1
_3 _ max -.015 I O 1 j O 2 0 2 0 2 .OZ] 2 __
1--'-4__,__ --~---__,m,--'-""in'+--_-_,_,,. Oc...c.1 =-5 _,__.....,_ -027 2 0 1 0 1 0 1 0 L
__§_~ 3 ma~ -.041 2~_ 0 1 I Q__f--2 0 2 0 2 .107 _2 J'
6 min -.042 1 -.053 2 0 1 0 1 0 1 0 1
7 4 max -.042 2 .027 2 0 2 0 2 0 2 _ _.,._0_53 __ z._
8 min -.044 1 O 1 O 1 O 1 O 1 o 1
9 5 max -.044 2 .027 2 0 2 0 2 0 , 2 , 0 2
f--'-1 =-0 -+----+------1'-m.'.-"i.,_,n+----.,_,.-0'-'-45 1 0 1 0 1 0 1 0 1 0 _ _1_
11 M2 __ 1 max. -.046 _ 1 0 1 0 2 0 2 , 0 2 0 .2_,
_j_2__ __ _ _min -.049 _ 2 _ -.Qo3_ 2 _g_ 1 o +4-l o:~1 r c f __ 1
-1..3'-l----+--_.,2 max -.045 1 o_ J___ 0 2 0 2 9 +r-,-004 .2_
_14 _ +---min,_ -.048 2_ -.003 2 0 1 0 _ 1 0 I J O 1
_j ~ 3 ma~Q4A_ _ 1 0 1 0 2 0 2 0 2 .008 2
_1.§_ _ ___ mini -.047 2 ---.003 2 0 -J_ 0 1 O .. . 1 :0-02 I 1
17 4_--J_m_ax.l--..::,..Q.43 __ 1 0 1 0 _,.J_ 0 _,..2_. 0 .2 .012 '2
_1~8'-+------~ mini -.045 2 -.003 2 0 1 0 1 _O_ 1 .00:]1j
19~-5 max -.006 1 .003 2 0 2 0 2 _o_. 2 f .P 2
i-=20~----+-----+'--'--'-'mi ril -.006 2 -.003 1 0 1 0 1 0 1 O 1
r-=2~1 -~M=3~__,_ __ 1~_....,.m_a_x_J -. 059 1 0 1 0 2 0 2 I O 2 1 0 I 2
f-=22"--+----+-----f'm=in,.__--'-.=3 2 -. 024 2 0 1 0 1 0 1 L O 1
23 2 max -.05 1 0 1 0 2 0 2 1 o_ -~I .019 ' 2
24 min -.291 2 -.007 2 0 1 0 1 0 1 I O 1
1-=2=-5--+----+---3,,,,___+m_a_x+--_-.,_,,.0'--'-4_,_1 _+--_ _,__1 .01 2 0 2 0 2 0 2 .018 2
26 min -.281 2 0 1 0 1 0 1 0 1 0 1
>-=-27~----+---4-max -.031 1 .026 2 0 2 0 2 0 2 .001 1
28 _____ min -,m_ -~2-__ o 1 o _:1 o 1 o 1 I -.005 .--2
-~9 _____ --J---'Sc__ max -.018 2 .003 1 0 2 0 2 0 _,2_ I -.oq~
30 mlD -.018 __ j _ -.003 2 __ _g_ 1 o 1 o 1 -.ooz 12 I
f-_.,,,=-ii~-=·~--~~-M-~-
4-=--~~=:.:=--:~:_-~L ;~~~ _j __ J ~--1 -i-1-+-I J \~1~i
_3_5 -+---3 max .003 1 -.006 2 _Q_ 2 _o_ 2 _o_ 2__ 0 1
f-=-36~----+-------f'-m'--'-'-'-in --=-:::oo3 --2 -006 1 0 1 0 ~ 1 0 1 0 2
37 -f--.A_ ~-0 2 .006 2 0 2 __ 0 2 0 2 .002 2 1
>-=-38=---+---~--min O 1 .006 1 0 1 0 1 0 1 .0021J-7 39 5 max O 2 0 2 0 2 0 , .. .'Z O 2 0 --t{-
40 min O 1 0 1 0 1 0 1 0 1 0 4
4:1 -------'M=5--+
1
------"1 _ __, ...... m_ax~_-.002 1 .004 1 0 2 0 2 0_.2_ 0 2
min -.074 2 .003 2 0 1 0 1 0 1 0 1
2 max -.002 1 -.007 1 ' 0 2 0 2 0 2 .004 2 ,
min -.074 2 -.008 2 O 1 O 1 O 1 .003 1
45 J ~ maxj__ 0 _ 1 _.012 2 L O 2 0 1 2~ 0 2 .003 1 2 '
RISA-30 Version 17.0.4 (J:\RISA-30\2020\S.2008026 -Soffit.r3d] Page 3
..
Company
Designer
Job Number
Model Name
Plump Engineering, Inc.
BAB
S.2008026
PANDA -SOFFIT
Envelope Member Section Forces (Continued)
Member Sec Axialfkl LC
46 min -.08 2
I 47 4 ]max 0 1
48 min -.08 2
49 5 max 0 1
50 min -.08 2
51 M6 I 1 max .27 2
52 min 0 1
53 2 max .269 2
54 min -.001 1
55 3 'max i .268 2
56 min -.002 1
57 4 max1 .267 2
58 min -.003 1
' 59 5 max i .266 2
60 min -.004 1
Aug 12, 2020
5:03 PM
Checked By: GMP
v Shearfkl LC z Shearfkl LC Torauef. .. LC v-v Mom ... LC z-z Mom ... LC
.011 1 0 1 0 1 0 1 -.001 1
0 12 0 2 0 2 0 2 I -.007 2
0 1 0 1 0 1 0 1 -.009 1
-.01 2 0 2 0 2 0 2 0 2
-.012 1 0 1 0 1 0 1 0 1
0 2 0 2 0 12 0 2 0 2 1
0 ', 1 0 1 0 1 0 1 0 1
0 2 0 '2 0 2 0 2 0 2
0 1 0 1 0 1 0 1 0 1
I 0 2 0 2 0 2 0 2 0 2
0 1 0 1 0 1 0 1 0 1
0 ,2 0 2 0 2 0 2 0 2
0 1 0 1 0 1 0 1 0 1
0 2 0 2 0 2 0 2 0 2 '
0 ' 1 0 1 0 1 0 1 0 1
RISA-3O Version 17.0.4 [J:\RISA-3O\2020\S.2008026 -Soffit.r3d] Page 4
"
Commercial Gas Water Heaters
BTH-120(A) through BTH-250(A)
BTH-300(A) through BTH-500(A)
APPROX.
MODEL CAPACITY A B t~'(-'( ' ' 1'"CHEN:M K••cilfs,cM\
8TH-120{A) 60 / 227 3n.61 27.75n0.5
BTH-150(A) 100 / 379 Jn.62 11.15no.s
''\ 8THlo.199{.ll llOO / 179 3/lt.61 \. 21.75/711.5
BTH•250(A) 100/ 379 317.62 27.75170.5
BTH-300(A) 119/450.96 4.75112.07 33.12/84.12
8TH-400(A) 119/450.96 4.75/12.07 33.12184.12
8TH-500(A) 1191450.96 4.75/12.07 33.12/84.12
Electrical characteristics-120V-60Hz A.C.. 5.0 A
"A" in model represents ASME construction
Propane gas models available
~"-•~v•~,v~'---+--......,ID FRONT
D B
0
"""
F
B
DIMENSIONS
C D E F
IN~ESI~ 'i'NtHfficM'( IN'e'.HESI~ 'fNCHffiCM '(
6.3/16 35/88.9 55.5/141 53.5/135.9
6.3/16 56.381143.2 76/193.04 75.75/192.4
\. 6.311.6 56.l8/1U2 \.76/19,1,04 I 75.15/19:!..4
6.3/16 56.38/1431 767193.04 75.75/191.4
4.75/12.07 52.00/131.08 75. 751192.41 73.75/187.3
4.75/12.07 52.00/132.08 75.75/192.41 73.75/187.3
4.75112.07 52.00/132.08 75.751191.41 73.751187.3
~Smith.
\ ''"'" I oun<• ....... ,
E E
H F
J
, ..
FR0t'1
E
H
D >nPT
0 A:ECIACU..AnON M.n,;tN
J
G
A C
SHIPPING SHIPPING
WEIGHT WEIGHT
G H I J STD ASME
IN'e'.HESI~ '<iNCH~CM'\" lflbtESJIM '<'1Ncol(s,cM'I "C'tSJK1f '( UlfKG '(' 3 11.25/lB.6 42.25/107.32 48.5/123.2 18.25/46.36 460 / 208 490 / 220
11.25/28.6 64/162.6 70/177.8 1 B.25/46.36 523 / 237 553/251
111.15118.6 1 6!1161.i \ 70/1117.8 \ 18\l5!4ft.36 \5231,237, 5U/25.I
11.25118.6 64/162.6 70/177.8 18.25746.36 m,m ,53ns1
12.75/32.39 63.13/160.35 69.251175.9 23.00/58.4] 855 / 387 855 / 387
12.75/32.39 63.131160.35 69.25/175.9 23.00/58.43 855/ 387 855 / 387
12. 75132.39 63.131160.35 69.25/175.9 13.00158.43 855 I 387 855 I 387
For Technical Information and Automated Fax Service, call 800-527-1953. A. 0. Smith Corporation reserves the right to make product changes or improvements without prior notice.
Page 3 of 4
www.hotwater.com AOSCG10210
•
,Y
[)-.]
z' X
~lump Engineering , Inc.
l BAB
S.2008026
T
PANDA -SOFFIT Aug 12, 2020 at 5:13 PM I I
S.2008026 -WH SUPPORT.r3d
•
• v
1 z" ·x
2
! Plump Engineering, Inc. !
BAB PANDA -SOFFIT 'Aug 12, 2020 at 5:13 PM
'
! S.2008026 i j S.2008026-WH SUPPORT.r3d
I.
----·----..--·········---····•·-·Vo-·-····~··•••-•·· -·-•---·•~-·---... -·-··-·
..
• v
z• X
2
Plump Engineerlng, Inc.
BAB
S.2008026
PANDA -SOFFIT . Aug 12, 2020 at 5:13 PM
S.2008026-WH SUPPORT.r3d
•
,Y
2
loads: BLC 1. DL
Plump Engineering, Inc.
BAB
S.2008026
-.511k
PANDA -SOFFIT
-.011</ft
Aug 12, 2020 at 5:13 PM
I S.2008026 -WH SUPPORT.r3d
~ I I -
Beam: M1
Shape: 2-600S162-43-BB
Material : A653 SS Gr33 Dy in
Length: 3 ft
I Joint: N1 Dz in
J Joint: N2
LC 1: DL
Code Check: 0.120 (bending) -.004 at 1.5 ft Report Based On 97 Sections
.275 at O ft
A k Vy k Vz k
-.275 at 3 ft
Mz k-ft
T --------k-ft My --------k-ft
-.398 at 1.5 ft
3.09 at 1.5 ft
ft ksi
fa --------ksi
fc ksi
-3.09 at 1.5 ft
A/SI S100-16: LRFD Code Check
Combined Shape Design does not consider weak axis 'My' Moments, nor weak axis 'Vz' Forces.
Max Bending Check 0.120 Max Shear Check 0.064 (y) Max Deft Ratio L/8513
Location 1.5 ft Location 0 ft Location 1.5 ft
Equation H2-1 Span 1
Gov. 0 Equation F2/F3
R (16.2.1) Not Used y-y z-z
Fy 33 ksi Lb 0 ft 3 ft A eff. (Fy) .582 jnA2
0*Pn 10.607 k KL/r 0 15.802 A eff. (Fn) ,589 jnA2
0 *Tn 26.552 k ly eff. NC
0*Mny NC L Comp Flange 0 ft Sy eff. (L) NC
0 *Mnz 3.821 k-ft L-torque 3 ft Sy eff. (R) NC
0*Vny 4.303 k Cw 4.33 jnA6 lz eff. 4.632 nA4
0*Vnz NC a (conn. spacing) 0 ft Sz eff. (T) 1.544 nA3
Cb 1.308 Sz eff. (B) 1.544 nA3
,-,~:;,,
{_ City of
Carlsbad
CAP Building Plan
Template
B-55
INSTRUCTIONS: The following certificate shall be included on the title sheet of all building plans:
CLIMATE ACTION PLAN (CAP) COMPLIANCE
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
The following demonstrates project compliance with the applicable Climate Action Plan ordinances of the Carlsbad Municipal Code and California
Green Building Standards Code (CALGreen), current version:
1. ENERGY EFFICIENCY APPLICABLE: @No
Complies with CMC 18.30.190
& 18.21.155
Existing Structure, year built: ____ _
Prepared Energy Audit?
Energy Score: _____ _
Efficiency Measures included in scope:
Yes/No
2. PHOTOVOLTAIC SYSTEM APPLICABLE: vest@)
Complies with CMC section 18.30.130 and 2019 California Energy
Code section 150.l(c)14 Yes /No
Required Provided
Size of PV system (kWdc):
Sizing PV by load calculations
If by Load Calculations:
Total calculated electrical load:
80%of load:
Hardship Requested
Hardship Approved
Yes/No
Yes/No
Yes/No
3. ALTERNATIVE WATER HEATING SYSTEM APPLICABLE: YE@
Complies with CMC sections 18.30.150
and 18.30.170? Yes /No
Alternative Source:
□ Electric
□ Passive Solar
Hardship Requested
Hardship Approved
4. ELECTRIC VEHICLE (EV) CHARGING APPLICABLE:
Complies with CMC
section 18.21.140?
Panel Upgrade?
Yes/No
Yes/No
YES~
Yes/No
Yes/No
Required Provided
Total EV Parking Spaces:
No. of EV Capable Spaces:
No. of EV Ready Spaces:
No. of EV Installed Spaces:
Hardship Requested
Hardship Approved
5. TRAFFIC DEMAND MANAGEMENT APPLICABLE:
Compliant?
TDM Report on file with city?
Yes/No
Yes/No
@No
Yes/ no
Yes/ no
Hazardous Materials Questionnaire
County of San Diego, Department of Environmental Health
PO Box 129261, San Diego, CA 92112-9261
Record ID #: Not in System
Plan Check#: DEH2020-HHMBP-008991
(858) 505-6700 (800) 253-9933 www.sdcdeh.org
Business Name Business Contact Telephone# Plan File#
Panda Express Panda Express. Inc. 6267999898
Project Address City Zip Code APN#
2641 Gateway Rd Carlsbad 1st~ 92009 2131912500
Applicant Applicant E-Mail App!icantT e\ephone #
Miguel Topete miguel@garywang.com 6267999898
The following questions represent the facility's activities, NOT the specific project description.
PART I; FIRE DEPARTMENT-HAZARDOUS METERIALS DMSION: OCCUPANCY CLASSIFICATION; (Not required for projects within the City of San Diego.)
Indicate by selecting the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are selected, Applicant must
contact the Fire Protection Agency with jurisdiction priorto plan submittal.
Occupancy Rating:
D Explosive or Blasting Agents
l!I Compressed Gases
□ Flammable/Combustible Liquids
D Flammable Solids
D Organic Peroxides
D Oxidizers
D Pyrophorics
□ Unstable Reactives
Facility's Square Footage (including proposed project):
□ Water Reactives □ Corrosives
D Cryogenics D Other Health Hazards
D Highly Toxic or Toxic Materials D None of These
□ Radioactives
PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION (HMO): If the answer to any of the questions is
yes, applicant must contact the County of San Diego Hazardous Materials Divisjon, in person at 5500 Ovettand Ave., Suite 110, San Diego, CA 92123, or by phone at(858)
505-6700 prior to issuance of a building permit. FEES ARE REQUIRED.
Project Completion Date: 512412021
1.
2.
3.
4.
5.
6.
7.
8.
YES NO
D Iii
□ liil
D liil
D liil
□ liil
D Iii
D 00
□ liil
Is your business listed on the reverse side of this form? (check all that apply).
WIii your business dispose of Hazardous Substances or Medical Waste in any amount?
VI/ill your business store or handle Hazardous Substances in quantities equal to or greater than
55 gallons, 500 pounds, or 200 cubic feet?
Will your business handle carcinogens or reproductive toxins in any quantity?
Will your business use an existing, or install an underground storage tank?
Will your business store or handle Regulated Substances (CalARP)?
VI/ill your business use or install a Hazardous Waste Tank System (Title 22, Article 10)?
VI/ill your business store petroleum in tanks or containers at your facility with a total storage capacity
equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act).
D
D
□
CalARP Exempt
CalARP Required
CalARP Complete
Review Date:
PART m· SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT IAPCDl: If the answer to Question #1 is 'Yes· and the answer to Question #2 is 'No', the applicant
must contact the APCD prior to the issuance of a buiding or demolition permit. If any answer to Questions #3, #4, or #5 is 'Yes', the applicant must contact the APCD prior to
the issuance of a building or demolition permit. If the answer to Question #3 or #4 is 'Yes·, the applicant may need to submit an asbestos notification form to the APCD at
least 10 working days prior to commencing demolition or renovation (some residential projects may be exempt from the notification requirements). Coma.ct the APCD at
10124 Old Grove Road, San Diego, CA 92131 or telephone (858) 586-2600 for more information.
1.
2.
3.
4.
YES NO
D liil
D Iii
D Iii
D Iii
Will any existing building materials be disturbed as part of this project? (If the answer is 'Yes', an asbestos survey may be required.)
Has a survey been performed to determine the presence of asbestos containing materials?
Will the project involve handling or disturbance of any asbestos containing materials?
WIii the project involve the removal of any load supporting structural member?
5. D Iii VI/ill the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD
factsheet at http/lwww.sdapcd.org/info/facts/permits.pdf
6. □ Iii (ANSWER ONLY IF QUESTION 5 IS 'YES') Will the subjectfaciity be located within 1,000 feet of the outer boundary of a school (K through 12)?
Search the California School Directory at http://www.cde.ca.gov/re/sdl for public and private schools or contact the appropriate school district.
Briefly describe business activities:
Fast Food Restaurant
Briefly describe proposed project:
Tenant improvement project in an existing building shell to Include non-bearing
partitions, gyp. board, ceiling, walk-in cooler/freezer, floor and wall finishes
I declare under penalty of perjury that to the best of my knowledge and belief, the responses made herein are true and correct Iii; Fees Acknowledged: Iii
Miguel Topete 8/20/2020
Name of Owner or Authorized Agent Date
FOR OFFICIAL USE ONLY
FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:
BY: DATE: __________ _
EXEMPT OR NO FURTHER IIIIFORMATION RELEASED FOR BUILDING PERMIT BUT NOT FOR RELEASED FOR OCCUPANCY
REQUIRED OCCUPANCY
COUNTY-HMD• APCD COUNTY-HMO APCD COUNTY-HMO APCO
-•~ GF S,v1 ~'-'-\\00 Co'J ,..,~\.\ . Do (f"-~00-~ t,._c, .q :,, RE ',li[.1.ifl'*-.D BY ~ Reviewed 0
S. Khalid < 09/02120 -ALF ~
-~~~:; '6 Oate/fnnii'is 0
c,'?. Jr tj.. Q"
Of Sa1'
•A stamp in this box 2!l!Y. exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may sm apply.
DEH HMD Plan Chock Questionnairev1.2(10/2015)
Printed on:91112020@1:12 PM
.. ····---···-· -----
;,
LIST OF BUSINESSES WHICH REQUIRE REVIEW AND APPROVAL FROM THE COUNTY OF SAN DIEGO
DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION
Check all that apply:
AUTOMOTIVE
D Battery Manufacturing/Recycling
D Boat Yard
O Car Wash
D Dealership Maintenance/Painting
D Machine Shop
D Painting
D Radiator Shop
D Rental Yard Equipment
D Repair/Preventive Maintenance
D Spray Booth
D Transportation Services
0 Wrecking/Recycling
CHEMICAL HANDLING
0 Agricultural supplier/distributor
0 Chemical Manufacturer
0 Chemical Supplier/Distributor
D Coatings/Adhesive
D Compressed Gas Supplier/Distributor
0 Dry Cleaning
D Fiberglass/Resin Application
D Gas Station
D Industrial Laundry
D Laboratory
D Laboratory Supplier/Distributor
0 Oil and Fuel Bulk Supply
0 Pesticide Operator/Distributor
CHEMICAL HANDLING
0 Photographic Processing
D Pool Supplies/Maintenance
0 Printing/Blue Printing
0 Road Coatings
D Swimming Pool
D Toxic Gas Handler
D Toxic Gas Manufacturer
METAL WORKING
D Anodizing
D Chemical Milling/Etching
D Finish-Coating/Painting
D Flame Spraying
D Foundry
D Machine Shop-Drilling/Lathes/Mills
0 Metal Plating
D Metal Prepping/Chemical Coating
D Precious Metal Recovery
D Sand Blasting/Grinding
D Steel Fabricator
D Wrought Iron Manufacturing
AEROSPACE
D Aerospace Industry
D Aircraft Maintenance
D Aircraft Manufacturing
OTHERS AND MISCELLANEOUS
0 Asphalt Plant
0 Biotechnology/Research
D Chiropractic Office
D Co-Generation Plant
D Dental Clinic/Office
D Dialysis Center
0 Emergency Generator
0 Frozen Food Processing Facility
D Hazardous Waste Hauler
D Hospital/Convalescent Home
D Laboratory/Biological Lab
0 Medical Clinic/Office
D Nitrous Oxide (NO,) Control System
D Pharmaceuticals
□ Public Utility
D Refrigeration System
D Rock Quarry
D Ship Repair/Construction
D Telecommunications Cell Site
D Veterinary Clinic/Hospital
D Wood/Furniture Manufacturing/Refinishing
ELECTRONICS
D Electronic Assembly/Sub-Assembly
D Electronic Components Manufacturing
D Printed Circuit Board Manufacturing
NOTE: THE ABOVE UST INCLUDES BUSINESSES, WHICH TYPICALLY USE, STORE, HANDLE, AND DISPOSE OF HAZARDOUS SUBSTANCES.
ANY BUSINESS NOT INCLUDED ON THIS LIST, WHICH HANDLES, USES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE
HAZARDOUS MATERIALS DIVISION (HMO) REVIEW OF BUSINESS PLANS. FOR MORE INFORMATION CALL (858) 505-6880.
LIST OF AIR POLLUTION CONTROL DISTRICT PERMIT CATEGORIES
Businesses, which include any of the following operations or equipment, will require clearance from the Air Pollution Control District.
CHEMICAL
47 -Organic Gas Sterilizers
32 -Acid Chemical Milling
33 -Can & Coil Manufacturing
44 -Evaporators, Dryers & Stills Processing
Organic Materials
24 -Dry Chemical Mixing & Detergent Spray
Towers
35 -Bulk Dry Chemicals Storage
55 -Chrome Electroplating Tanks
COATINGS & ORGANIC SOLVENTS
27 -Coating & Painting
37 -Plasma Arc & Ceramic Deposition Spray
Booths
38 -Paint, Stain & Ink Mfg
27-Prinling
27 -Polyester Resin/Fiberglass Operations
METALS
18 -Metal Melting Devices
19-Oil Quenching & Salt Baths
32 -Hot Dip Galvanizing
39 -Precious Metals Refining
ORGANIC COMPOUND MARKETING
(GASOLINE, ETC)
25 -Gasoline & Alcohol Bulk Plants & Terminals
25 -Intermediate Refuelers
26 -Gasoline & Alcohol Fuel Dispensing
COMBUSTION
34 -Piston Internal -Combustion Engines
13 -Boilers & Heaters (1 million BTU/hr or larger)
14-Incinerators & Crematories
15 -Bum Out Ovens
16 -Core Ovens
20 -Gas Turbines. and Turbine Test Cells & Stands
48 -Landfill and/or Digester Gas Flares
ELECTRONICS
29 -Automated Soldering
42 -Electronic Component Mfg
FOOD
12 -Fish Canneries
12 -Smoke Houses
50 -Coffee Roasters
35 -Bulk Flour & Powered Sugar Storage
SOLVENT USE
28-Vapor & Cold Degreasing
30 -Solvent & Extract Driers
31 -Dry Cleaning
ROCK AND MINERAL
04 -Hot Asphalt Batch Plants
05 -Rock Drills
06 -Screening Operations
07 -Sand Rock & Aggregate Plants
08 -Concrete Batch, CTB. Concrete Mixers, Mixers
& Silos
10 -Brick Manufacturing
OTHER
01 -Abrasive Blasting Equipment
03 -Asphalt Roofing Kettles & Tankers
46 -Reverse Osmosis Membrane Mfg
51 -Aqueous Waste Neutralization
11 -Tire Buffers
17 -Brake Debonders
23 -Bulk Grain & Dry Chemical Transfer & Storage
45 -Rubber Mixers
21 -Waste Disposal & Reclamation Units
36 -Grinding Booths & Rooms
40 -Asphalt Pavement Heaters
43 -Ceramic Slip Casting
41 -Perlite Processing
40-Cooling Towers -Registration Only
91 -Fumigation Operations
56-WVVTP (1 million gal/day or larger) & Pump
Station
NOTE: OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITTING AIR CONTAMINANTS MAY REQUIRE AN AIR POLLUTION
CONTROL DISTRICT PERMIT. IF THERE ARE ANY QUESTIONS, CONTACT THE AIR POLLUTION CONTROL DISTRICT AT (858) 586-2600.
HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division
Date: 09/03/20
ENCINA WASTEWATER AUTHORITY
INDUSTRIAL WASTEWATER DISCHARGE PERMIT
SCREENING SURVEY
6200 Avenida Encinas, Carlsbad, CA 92011
Phone: 760-438-3941 Fax: 760-476-9852
SourceControl@encinajpa.com
Business Name: Panda Express, Inc.
Street Address: 2641 Gateway Rd, Suite 101, Carlsbad, CA
Email Address: miguel@garywang.com
PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECI< TYPE OF BUSINESS) I ✓ I
Check all below that are present at your facility:
o Acid Cleaning
o Assembly
o Automotive Repair
o Battery Manufacturing
o Biofuel Manufacturing
o Biotech Laboratory
o Bulk Chemical Storage
o CarWash
o Chemical Manufacturing
o Chemical Purification
o Dental Offices
• Dental Schools
• Dental Clinics
o Dry Cleaning
o Electrical Component
Manufacturing
o Fertilizer Manufacturing
o Film/X-ray Processing
o Food Processing
o Glass Manufacturing
o Industrial Laundry
o Ink Manufacturing
o Laboratory
o Machining/Milling
o Membrane manufacturing
(i.e. water filter membranes)
o Metal Casting/Forming
o Metal Fabrication
o Metal Finishing
• Electroplating
• Electroless Plating
■ Anodizing
• Coating {i.e. phosphating)
■ Chemical Etching/Milling
• Printed Circuit Board
Manufacturing
o Metal Powders Forming
o Nutritional Supplement/Vitamin
Manufacturing
o Painting/Finishing
o Paint Manufacturing
o Personal Care Products
Manufacturing
o Pesticide Manufacturing/ Packaging
o Pharmaceutical Manufacturing
(including precursors)
o Porcelain Enameling
o Power Generation
o Print Shop
o Research and Development
o Rubber Manufacturing
o Semiconductor Manufacturing
o Soap/Detergent Manufacturing
o Waste Treatment/Storage
New Business? Yes!Z1No0 SIC Code(s) if known: ______ Date operation began/will begin: 5124I2021
Tenant Improvement? Yes[Z]No[J If yes, briefly describe improvement: _________________ _
Interior T.I. of an existing space to a Panda Express Restaurant.
Description of operations generating wastewater (discharged to sewer, hauled or evaporated): __________ _
Cleaning & Ware Washing
Estimated volume of industrial wastewater to be discharged (gal/ day): _3_0_0_g_a_ll_d_a_y _____________ _
List hazardous wastes generated (type/volume):_N_/_A ________________________ _
Have you applied for a Wastewater Discharge Permit from the Encit1a Wastewater Authority? YesD Date: ____ No(Z] ·
Page 1 of2
-----·-···-----
ENCINA WASTEWATER AUTHORITY
INDUSTRIAL WASTEWATER DISCHARGE PERMIT
SCREENING SURVEY
6200 Avenida Encinas, Carlsbad, CA 92011
Phone: 760-438-3941 Fax: 760-476-9852
SourceControl@encinajpa.com
The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater
discharge permitting under normal operating conditions. They are exempt because {a) they discharge no process wastewater
(Le., they only discharge sanit.uy wastewater with no pollutants exceeding any local limits}, and (b) they have no potential to
negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions
should be referred to EWA Source Control staff.
o Automobile Oetailers
o Barber/Beauty Shops
o Business/Sales Offices
o Cleaning Services
o Carpet/Upholstery
o Childcare Facilities
a Churches
o Community Centers
o Consulting Services
o Contractors
o Counseling Services
o Hotels/Motels (no laundry)
o Laundromats
o Libraries
o Medical Offices (no x-ray developing)
o Mortuaries
o Museums
o Nail Salons
o Nursing Hornes
o Office Buildings (no process flow)
o Optical Services
o Pest Control Services (no pesticide repackaging for sale)
o Educational Services (no auto repair/film developing) o Pet Boarding/Grooming Facilities
o Financial Institutions/Services o Postal Services {no car wash/auto repair)
o Fitness Centers o Public Storage Facilities
o Gas Stations (no car wash/auto repair) o Restaurants/Bars
o Grocery Stores (no film developing) o Retail/Wholesale Stores (no auto repair/film developing)
o Residential based Businesses o Theaters (Movie/live)
CERTIFICATION STATEMENT
I certify that the Information above is true and correct to the best of my knowledge.
Print Name: Miguel Topete DATE: 09/03/20
Facility Contact: Panda Express Title: Job Captain
ENCINA WASTEWATER AUTHORITY
6200 AVENIDA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852
SourceControl@encinajpa.com
Page 2 of 2
-----· · ................................. _ .. _, ........... ., ... .
( City of
Carlsbad
PURPOSE
CLIMATE ACTION PLAN
CONSISTENCY CHECKLIST
8-50
Development Services
Building Division
1635 Faraday Avenue
(760) 602-2719
www.carlsbadca.gov
This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance
requirements apply to their projects. The completed checklist must be included in the building permit application. It may be
necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate
full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach
to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as
specified by the ordinances.
NOTE: The following type of permits are not required to fill out this form
❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool
-' If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance,
an explanation must be provided to the satisfaction of the Building Official.
..1111 Details on CAP ordinance requirements are available on the city's website .
..1111 A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be
completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and
download the latest form.
Project Name/Building
Permit No.: Panda Express, Inc. BP No.: CBC2020-0337
Property Address/APN: 2641 Gateway Rd. Suite 101
Applicant Name/Co.: Miguel Topete
Applicant Address: 1000 Corporate Center Dr, Suite 550, Monterey Park, CA 91754
Contact Phone : 626.288.6898 Contact Email: miguel@garywang.com
Contact information of person completing this checklist (if different than above):
Name:
Company
name/address:
Contact Phone:
Contact Email:
Applicant Signature:-~-=-: ........ ~--.&...~-~""-=-""--------Date: 10-05-20
B-50 Page 1 of 6 Revised 08/19
" City of Carlsbad Climate Action Plan Consistency Checklist
Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project.
For alterations and additions to existing buildings, attach Building Permit Valuation worksheet.
Building Permit Valuation (BPV) from worksheet: $_2_00_,o_o_o._oo ___ _
Construction Type
D Residential
D New construction
D Additions and alterations:
D BPV < $60,000
D BPV:::: $60,000
D Electrical service panel upgrade only
D BPV :::: $200,000
[Z] Nonresidential
D New construction
0 Alterations:
0 BPV:::: $200,000 or additions:::: 1,000
square feet
D BPV 2:: $1 ,000,000
□ :::: 2,000 sq. ft. new roof addition
Checklist Item
Complete Section(s) Notes:
A high-rise residential building is 4 or more stories, including a
Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor
area is residential use
2A, 3A, 1B, 2B,
4A 3B,4A
N/A N/A All residential additions and alterations
1A,4A 4A 1-2 family dwellings and townhouses with attached garages
only
*Multi-family dwellings only where interior finishes are removed
1A, 4A* 1B,4A* and significant site work and upgrades to structural and
mechanical, electrical, and/or plumbing systems are proposed
1 B, 2B, 3B, 4B and 5
1B, 5
1B,2B ,5 Building alterations of:::: 75% existing gross floor area
2B, 5 1 B also applies if BPV:::: $200,000
Check the appropriate boxes, explain all not applicable and exception Items, and provide supporting calculations and documentation as necessary.
1. Energy Efficiency
Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for
more infonnation when completing this section.
A D Residential addition or alteration ~ $60,000 building pennit valuation.
See CMC section 18.30.190.
Year Built Single-family Requirements
□ Before 1978 Select one:
□ Duct sealinq □ Attic insulation □Cool roof
□ 1978 and later Select one:
□ Lighting package □ Water heating Package
□ Between 1978 and 1991
□ 1992 and later
□ NIA -----------
□ Exception: Home energy score~ 7
(attach certification)
Multi-family Requirements
□ Attic insulation
Select one:
□ Duct sealing □ Attic insulation □Cool roof
Select one:
□ Lighting package □ Water heating package
B. 0 Nonresidential* new construction or alterations~ $200,000 building pennit valuation ,
or additions ~ 1,000 square feet □ NIA
Updated 8/ 15/20 I 9 2
.
City of Carlsbad Climate Action Plan Consistency Checklist
See CMC 18.21.155 and CAL Green Appendix AS, Division AS.2 -Energy Efficiency.
A5.203.1.1 Choose one: □ .1 Outdoor lighting □ .2 Warehouse dock seal doors
□ .3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended) □ N/A _________ _
0 .4 Daylight design PAFs □ .5 Exhaust air heat recovery
A5.203.1.2.1
Choose one as applicable: □ .95 Energy budget 0 .90 Energy budget □ N/A
A5.211.1""
□ On-site renewable energy □ NIA
A5.211.3""
□ Green power (if offered by local utility provider, 50% minimum renewable sources) □ N/A
A5.212.1
□ Elevators and escalators 12] NIA T.I. Only
A5.213.1
□ Steel framing 0 NIA T.I. Only
• Includes hotels/motels and high-rise residential buildings
""For alterations~ $1 ,000,000 BPV and affecting> 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply
with CMC 18.30.130 instead.
2. Photovoltaic Systems
A. 0 Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California
Energy Code section 150.1{c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic
requirement (28 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(8)
(high-rise residential) or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PV offset option is selected.
Floor Plan ID (use additional CFA #d.u. Calculated k\flklc*
sheets if necessary)
Total System Size:
k\flklc = (CFAx.572) / 1,000 + (1.15 x #d.u.)
*Formula calculation where CFA = conditional floor area, #du= number of dwellings per plan type
If proposed system size is less than calculated size, please explain.
Exception
□
□
□
□
k\flklc
8. D Nonresidential new construction or alterations ~$1,000,000 8PV and affecting ~75% existing floor area, or addition that increases roof
area by ~2,000 square feet Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to
high-rise residential and hotel/motel buildings.
Choose one of the following methods:
□ Gross Floor Area (GFA) Method
GFA:
□If< 10,000s.f. Enter: 5 kWdc
Min. System Size:
□ If ~ 10,000s.f. calculate: 15 kWdc x (GFA/10,000) ••
__ kWdc
**Round building size factor to nearest tenth, and round system size to nearest whole number.
□ Time-Dependent Valuation Method
Updated 8/15/20 19 3
' . City of Carlsbad Climate Action Plan Consistency Checklist
Annual TDV Energy use:*** ______ x .80= Min. system size: _____ kWdc
***Attach calculation documentation using modeling software approved by the California Energy Commission.
3. Water Heating
A D Residential and hotel/motel new construction
Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section.
D For systems serving individual dwelling units choose one:
D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise
residential only)
D Heat pump water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise
residential hotel/motel) or CA Energy Code section 150.1 (c) 14 (low-rise residential)
D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher
D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors
D Exception:
D For systems serving multiple dwelling units, install a central water-heating system with all of the following:
D Gas or propane water heating system
D Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low-
rise residential)
D Solar water heating system that is either:
D .20 solar savings fraction
D .15 solar savings fraction, plus drain water heat recovery
D Exception:
B. D Nonresidential new construction
Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section.
D Water heating system derives at least 40% of its energy from one of the following (attach documentation):
D Solar-thermal D Photovoltaics D Recovered energy
□Water heating system is (choose one):
0 Heat pump water heater
D Electric resistance water heater(s)
□Solar water heating system with .40 solar savings fraction
D Exception:
Updated 8/1 5/20 19 4
City of Carlsbad Climate Action Plan Consistency Checklist
4. Electric Vehicle Char in
A. D Residential New construction and major alterations*
Please refer to Carlsbad Ord inance CMC section 18.21.140 when com letin this section.
One and two-family residential dwelling or townhouse with attached garage:
D one EVSE Ready parking space required D Exception :
D Multi-family residential· D Exception ·
Total Parking Spaces EVSE Spaces
Proposed Capable Ready
Calculations: Total EVSE spaces= .10 x Total parking (rounded up to nearest whole number)
EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest whole number)
EVSE other= Total EVSE spaces -EVSE Installed
(EVSE other may be "Capable," "Ready" or "Installed.")
Installed Total
*Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation ~ $60,000
or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit
valuation ~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing
systems are proposed.
B. D Nonresidential new construction (includes hotels/motels) D Exception :
Total Parking Spaces EVSE Spaces
Proposed Capable I Ready I Installed I Total
10 2 I 5 I 1 I 8
Calculation: Refer to the table below:
Total Number of Parkinq Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces
□ 0-9 1 1
□ 10-25 2 1
□ 26-50 4 2
□ 51-75 6 3
□ 76-100 9 5
□ 101-150 12 6
□ 151-200 17 9
□ 201 and over 10 percent of total 50 percent of Required EV Spaces
Updated 8/15/20 I 9 5
' c'ity of Carlsbad Climate Action Plan Consistency Checklist
5. 0 Transportation Demand Management (TOM): Nonresidential ONLY
AA approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT.
City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TOM plan. If TOM is applicable to your
permit, staff will contact the applicant to develop a site-specific TOM plan based on the permit details.
Acknowledgment:
Employee ADT Estimation for Various Commercial Uses
EmpADTfor
first 1,000 s.f.
EmpADTI
1000 s.f.1
Office (all)2 20
Restaurant 11
Retaib 8
Industrial 4
Manufacturing 4
Warehousin 4
1 Unless otherwise noted, rates estimated from /TE Trip
Generation Manual, 10th Edition
13
11
4.5
3.5
3
1
2 For all office uses, use SAN DAG rate of 20 ADT/1 ,000 sf to
calculate employee ADT
3 Retail uses include shopping center, variety store, supermarket,
gyms, pharmacy, etc.
Other commercial uses may be subject to special
consideration
Sample calculations:
Office: 20,450 sf
1. 20,450 sf/ 1000 x 20 = 409 Employee ADT
Retail: 9,334 sf
1. First 1,000 sf = 8 ADT
2. 9,334 sf -1,000 sf = 8,334 sf
3. 8,334 sf/ 1,000 x 4.5 + 8 = 46 Em lo ee ADT
I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should
my permit require a TOM plan and understand that an approved TOM plan is a condition of permit issuance.
Applicant Signature: __.~<.......;...~~=-..._----'-,V-:,.,.-..,,d:-_.__ ________ _ ---;;r ., Date: 10-05-20
Person other than Applicant to be contacted for TOM compliance (if applicable):
Name (Printed): __________________ _ Phone Number: ------
Email Address: ___________________ _
Updated 8/1 5/2019 6
PERMIT REPORT
Revision Permit
Print Date: 05/13/2021
Job Address: 2641 GATEWAY RD, # 101, CARLSBAD, CA 92009-1754
{Cityof
Carlsbad
Permit No: PREV2021-000S
Status: Closed -Finaled
Permit Type: BLDG-Permit Revision Work Class: Commercial Permit Revis
Parcel#: 2131912500 Track#:
Valuation: $0.00 Lot#:
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Project Title:
Project#:
Plan#:
Construction Type:
Orig. Plan Check#: CBC2020-0337
Plan Check#:
Description: PANDA EXPRESS: FLOOR PLAN REVISED AND INTERIOR CHANGES
FEE
BUILDING PLAN CHECK REVISION ADMIN FEE
MANUAL BLDG PLAN CHECK FEE
Property Owner:
REGENCY BRESSI LLC
100 WILSHIRE BLVD, # 700
SANTA MONICA, CA 90401
Total Fees: $147.50 Total Payments To Date:
Building Division
$147.50
Applied: 01/11/2021
Issued: 02/10/2021
Finaled Close Out: 05/13/2021
Inspector: CRenf
Final Inspection:
Contractor:
ROCKWALL CONSTRUCTION COMPANY
4345 E LOWELL ST, # STE H
ONTARIO, CA 91761-2222
(909) 972-8216
Balance Due:
AMOUNT
$35.00
$112.50
$0.00
Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.cartsbadca.gov
, ..... -~ ......... ------•··• ... ,,,, ..... ~.
--------------\-.------------------
{City of
Carlsbad
PLAN CHECK REVISION OR
DEFERRED SUBMITTAL
APPLICATION
B-15
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
Original Plan Check Number CBC2020-0337 Plan Revision Number'Yi?t:~OJ.-/-0~
Project Address 2641 Gateway Rd.,Suite 101, Carlsbad, CA
G IS f R . . t/D & d 5 b ·tt I Revised Water Heater, Mop Sink, Co2 Tank location enera cope o ev1s1on eierre u m, a: _________________ _
and updated Plumbing & Electrical accordingly
CONTACT INFORMATION:
Name Miguel Topete Phone 6262886898 Fax ( cell) 323353417 4
Address 1000 Corporate Center Dr. Suite 550 City Monterey Park Zip 91754
Email Address miguel@garywang.com
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1 . Elements revised: Ii] Plans D Calculations D Soils Iii Energy D Other
2. 3.
Describe revisions in detail List page(s) where each
revision is shown
Please see Response Letter for reference.
4. Does this revision, in any way, alter the exterior of the project? D Yes liJ No
5. Does this revision add ANY new floor area(s)7 D Yes Ii] No
6. Does this revision affect any fire related issues? D Yes D No
7. Is this a complete set7 D Yes Iii No
,gSignature ~7ir4 Date O 1 /06/21
I 635 Faraday Avenue, carlsbad, CA 92008 eh: 76D-602-27 l 9 fa; 760-602-8558 Ema.It building@carlsbadca.gov
\j\,WW,carlsbadca.gov
DATE: 2/1/2021
JURISDICTION: Carlsbad
✓. EsG1I
A SAFFhu,it Comrany
PLAN CHECK#.: PREV2021-0005 (CBC2020-0337)
PROJECT ADDRESS: 2641 Gateway Rd.
SET: I
PROJECT NAME: REVISION #1: Panda Express Restaurant T.J.
□ APPLICANT
□ JURIS.
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
Miguel Topete
~ EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Miguel Topete Telephone#: 626-288-6898
Date contacted: (by: ) Email: miguel@garywang.com
Mail Telephone
0 REMARKS:
By: Steven Miller
EsGil
Fax In Person
Enclosures:
1/12/2021
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad
PREPARED BY: Stephen Miller
BUILDING ADDRESS: 2641 Gateway RD
BUILDING OCCUPANCY:
PLAN CHECK#.: CBC-2020-0337
DATE: 02/01/2021
BUILDING
PORTION
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
1997 UBC Building Permit Fee
I: ·.l\,f \;i :.
1997 UBC Plan Check Fee
AREA Valuation
(Sq.Ft.) Multiplier
#N/A
...
...
Type of Review: D Complete Review
D Repetitive Fee
,.. [ Repeats
• Based on hourly rate
□ Other
G Hourly
EsGil Fee
Reg. VALUE
Mod.
D Structural Only
1-------11 I Hr. @"
$90.00_
($)
~omme1~;) fofthe ~.r::~~"~~r:_above {ee, an aadltionidfee of$> .. • :. ·.·. is due f
Sheet
, -···•-----~-----•·"-,.
$90.001
. hour@
of