Loading...
HomeMy WebLinkAboutPRE 2021-0026; 1004 MERGANSER LANE; Admin Decision LetterAugust 4, 2021 Steve Mark Marrokal Design & Remodeling 9474 Kearney Villa Road, Ste. 205 San Diego, CA 92126 SUBJECT: PRE 2021-0026 (DEV 2021-0126) -1004 Merganser Lane APN: 215-760-04 {"Cityof Carlsbad 8FILE COPY ff/111'/t:I B/s/zt Thank you for submitting a preliminary review for an 896-square-foot (SF), detached accessory dwelling unit (ADU) located at 1004 Merganser Lane. The property is currently developed with a 4,712-square- foot single-family home. In response to your application, the Planning Division has prepared this comment letter. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. This preliminary review does not represent an in-depth analysis of your project. It is intended to give you feedback on critical issues based upon the information provided in your submittal. This review is based upon the plans. policies. and standards in effect as of the date of this review. Please be aware that at the time of a formal application submittal, new plans, policies, and standards may be in effect and additional issues of concern may be raised through a more specific and detailed review. Planning: General 1. General Plan and zoning designations for the property are as follows: a. General Plan: Residential, 0-4 dwelling units per acre (R-4) b. Zoning: Planned Community (P-C) c. Aviara Master Plan, MP 177(DD) d. The subject parcel is located in the Coastal Zone. The project is located in the California Coastal Commission's Appeal Jurisdiction. 2. The project requires the following permits: a. Minor Coastal Development Permit (CDP). While the project is located in the California Coastal Commission's (CCC) Appeal Jurisdiction and a public notice is required, the CCC cannot appeal a Minor CDP for an accessory dwelling unit. Please refer to the link below for the Minor CDP application (P-6) https://www.carlsbadca.gov/home/showpublisheddocument/506/637571071079830000 Community Development Planning Division I 1635 Faraday Avenue Carlsbad, CA 92008-7314 I 760-602-4600 I 760-602-8560 f I www.carlsbadca.gov PRE 2021-0026 -HUANG RESIDENCE August 4, 2021 Page 2 b. It is unknown at this time if a grading permit is required. The additional information requested in this letter by Land Development Engineering will assist staff with this determination. c. Building permit 3. Aviara Master Plan. MP 177(DD). The project site is located within Planning Area 30 of MP 177(DD). Pursuant to MP 177(DD), unless otherwise noted in the MP, all development shall conform to the development standards of the R-1 Zone (Carlsbad Municipal Chapter 21.10). 4. Climate Action Plan (CAP). New requirements related to the city's goals to reduce greenhouse gas (GHG) emissions will likely impact development requirements of this project. A formal application submittal will need to include a completed CAP Checklist (Form P-30) to determine what requirements will apply to the project. New GHG reduction requirements are related to energy efficiency, photovoltaic, electric vehicle charging, water heating and traffic demand management requirements, as set forth in the California Green Building Standards Code and in CMC Chapters 18.21, 18.30 and 18.51 which is available on the city's website at the following address: http://www.geode.us/codes/ ca rlsbad/view. ph p ?topic= 18&fra mes=on To the extent that new GHG reduction requirements are in effect at the time of application for grading or building permits, the project will be required to comply with the effective requirements even if different than what is proposed in the project's planning approvals. GHG reduction requirements may impact, but are not limited to, site design and local building code requirements. If incorporating new GHG reduction requirements results in substantial modifications to the project after planning approvals are obtained, then prior to issuance of grading or building permits, the applicant may be required to submit and receive approval of a Consistency Determination or an Amendment application for the project through the Planning Division. 5. Title Report. Please submit a current title report dated within the last six (6) months. Please discussion in No. 6 below for reference. 6. Setbacks for Detached ADU from Batiquitos Drive. The subject property abuts Batiquitos Drive to the north and Merganser Lane to the south. The detached ADU is proposed to be constructed adjacent to and slightly north of the existing single-family home, in an area which would typically be characterized as the rear yard. Pursuant to CMC Section 21.04.260, the lot meets the definition of a through lot with two street frontages. As a result, the subject lot has two front yard setbacks. Pursuant to CMC Section 21.46.180, the ADU shall not be located closer to either street than the distance constituting the front yard for such street. Further, pursuant to state laws relating to ADUs, an ADU shall not be located in the required front yard setback. The front yard setback for properties in the R-1 zone is 20 feet. Pursuant to MP 177(DD), all structures shall be setback a minimum of 35 feet from the property line which abuts Batiquitos Drive. Based on the information provided above regarding through lots and state law relating to setbacks for ADUs, staff has determined the maximum setback that can be required off Batiquitos Drive for the ADU is 20 feet , which is the required front yard setback in the R-1 Zone. The 35-foot-wide setback off Batiquitos Drive specified in MP 177(DD) is intended for aesthetic reasons and cannot be applied to the ADU pursuant to state laws relating to ADUs. PRE 2021-0026-HUANG RESIDENCE August 4, 2021 Page 3 7. 8. 9. Based on a review of the site plan submitted, a setback of 26 feet is proposed between the ADU and the north property line which abuts Batiquitos Drive. As currently designed, the project complies with requisite 20-foot-wide front yard setback. Please be advised this determination is dependent on the results of the title report. The structure cannot be located in an area with any recorded easements. Therefore, the final determination regarding the acceptability of the structure's location on the site will be determined once the title report has been reviewed. ADU Separation Requirements from Existing Home. A majority of the detached ADU.is proposed to be setback from the home the requisite 10 feet. A small portion of the ADU is located eight (8) feet from the existing chimney of the home. As chimneys are allowable projections, the separation distance proposed between the ADU and the home are acceptable. Building Height. While building elevations were not provided, please ensure that all elevations include an existing and proposed/finished grade. The building height shall be taken from the lower of the two measurements to the peak of the roof. The maximum allowable height for the detached ADU is 16 feet. · Cover Sheet. Please ensure the following information and clarifications are included as part of the submittal for the Minor CDP: a. Label the location of the chimney and setback between the home and proposed ADU b. Identify the 20-foot-setback off Batiquitos Drive and remove reference to the 4' rear yard setback for the ADU c. Under "Project Data," please indicate the property is located in the Aviara Master Plan, MP 177(DD) d. Under "Scope of Work," please add the proposed height (to peak of roof) and size for the detached ADU. All necessary application forms, submittal requirements, and fee information are available at the Planning counter located in the Faraday Building at 1635 Faraday Avenue or on line at www.carlsbadca.gov. You may also access the General Plan Land Use Element and the Zoning Ordinance online at the website address shown; select Department Listing; select Planning Home Page. Please review all information carefully before submitting. Land Development Engineering: 1. Complete the city's Storm Water Standards Questionnaire (Form E-34). This questionnaire will guide you and the City in determining what type of reports and storm water mitigation must be completed to satisfy state and City storm water quality requirements. The questionnaire can be obtained on the city's web site. Preliminary analysis suggests that the project is a 'Standard' Project and shall provide two completed Standard Project Requirement Checklist (E-36 Form). The form is available on the city's website. 2. A preliminary title report dated within 6 months of the application date is required with the submittal of a discretionary application and final enginee~ing application. Show and label on the plans, all easements listed in said report. If the easement cannot be shown, list the easement on the plan and state "non-plottable". 3. On the site plan, indicate the total proposed impervious area and total proposed pervious area in square feet. PRE 2021-0026 -HUANG RESIDENCE August 4, 2021 Page 4 4. Show all existing and proposed contour lines and spot elevations to determine the existing and proposed drainage pattern and determine the extent of the proposed grading (i.e. max. cut/fill). 5. Indicate the volume of grading (cut, fill, import, export, remedial) proposed for the project in cubic yards. 6. Show and label on the plans, the sewer service (lateral) and cleanout and the water lateral and water meter with backflow. 7. Show existing structures, contour lines and spot elevations on the adjacent properties, up to 25 feet beyond the property line. Provide multiple cross-sections to illustrate differences in grade. 8. Lot drainage shall comply with engineering standard GS-15. Provide a minimum of 2% grade away from the· building if hardscaped and a minimum of 5% grade away from the building for landscaped per 2016 California Building Code Section 1804.4. Show high points, flowline elevations, percent grades and show the directions lot drainage using drainage arrows. Show invert elevations of any proposed storm drainpipes. Verify the invert elevation of the existing storm drainpipe to connect to. Fire Department: 1. Fire sprinklers are only required if the existing home has fire sprinklers. Building Division: 1. Rated construction is required when the building is closer than 5 feet to a property line. Please see Table R302.1(1) for details. 2. The proposed detached ADU constitutes new construction such that compliance with the Climate Action Plan is required. Please complete the B-50 Climate Action Plan application and provide complete details for Sections 2A, 3A and 4A .. If you would like to schedule a meeting to discuss this letter with the commenting departments, please contact Shannon Harker at the number below. You may also contact each department individually as follows: • Planning Division: Shannon Harker, Associate Planner, at (760) 602-4621 • Land Development Engineering: Emad Elias, Project Engineer, at (760) 602-2733 • Fire Department: Randy Metz, Fire Marshal, at (760) 602-4661 • Building Division: Jason Pasuit, Building and Code Enforcement Manager, at (760) 602-2788 Sincerely, ~?t DON NEU, AICP City Planner DN:SH:cf c: Edwin Huang, 1004 Merganser Lane, Carlsbad, CA 92011 Emad Elias, Project Engineer File Copy Data Entry/Laserfiche