Loading...
HomeMy WebLinkAbout1893 ARTEMISIA CT; ; CBRA2020-0211; PermitBuilding Permit Finaled (city of Carlsbad Residential Associated Permit Print Date: 06/10/2021 Job Address: 1893 ARTEMISIA CT, CARLSBAD, CA 92011 Permit Type: BLDG-Associated Permit Residential Work Class: Parcel#: 2150530141 Track#: Valuation: $328,736.65 Lot#: Occupancy Group: #of Dwelling Units: 1 Bedrooms: 3 Project#: Plan#: Construction Type: Condo CT140010 103 DEV14060 Bathrooms: 3.0 Occupant Load: Orig. Plan Check#: PC2020-0009 Plan Check#: PC2020-0050 Code Edition: Sprinkled: Project Title: POINSETTIA 61 Permit No: CBRA2020-0211 Status: Applied: Issued: Finaled Close Out: Inspector: Final Inspection: Closed -Finaled 12/01/2020 12/16/2020 PBurn 06/10/2021 Description: POINSETTIA 61 (TREVISO): PHASE 14 / LOT 103 / PLAN 3 / 2,048 LIVING/ 447 SF GARAGE/ 68 SF PATIO Applicant: Property Owner: LENNAR COMMUNITIES INC ALAN CHIK 25 ENTERPRISE, # 400 ALISO VIEJO, CA 92656-2708 (949) 204-4628 LENNAR HOMES OF CALIFORNIA INC 15131 ALTON PKWY, # UNIT 365 IRVINE, CA 92618-2385 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) (949) 204-4628 COMMUNITY FACILITIES DISTRICT (CFD) FEE -RES ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PARK IN-LIEU FEES SF DETACHED & DUPLEX: SW PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFD SB1473 GREEN BUILDING STATE STANDARDS FEE SEWER BENEFIT AREA FEES -J SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1 -Medium BLDG TRAFFIC IMPACT Residential Condo Outside CFD Total Fees: $31,044.19 Total Payments To Date: Building Division $31,044.19 Contractor: LENNAR HOMES OF CALIFORNIA INC 15131 ALTON PKWY, # UNIT 365 IRVINE, CA 92618-2385 (949) 204-4628 Balance Due: AMOUNT $1,438,9S $926.68 $3,617.04 $66,00 $175.00 $92.00 $5,728.00 $182,00 $11,505.78 $14.00 $2,112.00 $998,00 $42.74 $246.00 $3,900.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov ----· --...... ___ _ Permit Type: Work Class: Status: Scheduled Date BLDG-Associated Permit Residenti, Application Date: Condo Issue Date: Closed -Finaled Expiration Date: IVR Number: Actual Inspection Type Start Date Inspection No. Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS Thursday, June 10, 2021 12/01/2020 Owner: LENNAR HOMES OF CALIFORNIA INC 12/16/2020 Subdivision: 09/28/2021 Address: 1893 ARTEMISIA CT 30545 CARLSBAD, CA 92011 Inspection Primary Inspector Reinspection Inspection Status Passed Yes Yes Yes Yes Yes Page 3 of 3 Permit Type: Work Class: Status: Scheduled Date 04/01/2021 05/07/2021 06/09/2021 06/10/2021 . ' ' --* -- PERMIT INSPEC'l;lQH. HI$TQ&Yi,for (CBRA2020-0211), . BLDG-Associated Permit Residenti, Application Date: 12/01/2020 Owner: LENNAR HOMES OF CALIFORNIA INC Condo Issue Date: 12/16/2020 Subdivision: Closed -Finaled Expiration Date: 09/28/2021 Address: 1893 ARTEMISIA CT IVR Number: 30545 CARLSBAD, CA 92011 Actual Start Date Inspection Type Inspection No. Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS Inspection Primary Inspector Status 04/01/2021 BLDG-82 Drywall, 154053-2021 Passed Tony Alvarado Exterior Lath, Gas Test, Hot Mop Checklist Item COMMENTS BLDG-17 Interior Lath-Drywall April 1, 2021: (drywall and gas test) -approved. 1. No building/drywall nailing Deficiencies. 2. Installation of new drywall type and drywall nailing pattern, per structural engineered plans and detail specifications, scope of drywall work.approved. 3. Gas test under air pressure leak test with gauge•approved. BLDG·23 Gas• Test.Repairs April 1, 2021: (drywall and gas test) •approved. 1. No building/drywall nailing Deficiencies. 2. Installation of new drywall type and drywall nailing pattern, per structural engineered plans and detail specifications, scope of drywall work-approved. 3. Gas test under air pressure leak test with gauge.approved. 05/07/2021 BLDG-Electric Meter Release 156840-2021 Passed Paul Burnette Checklist Item COMMENTS BLDG•Building Deficiency 06/07/2021 BLDG-Final Inspection Checklist Item 159044-2021 COMMENTS BLDG•Building Deficiency BLDG•Plumbing Final BLDG·Mechanical Final BLDG•Structural Final BLDG•Electrical Final 06/10/2021 BLDG-Final Inspection 159416-2021 Failed Paul Burnette Passed Chris Renfro Reinspection Passed Yes Yes Yes Yes Yes Passed Yes Yes Passed Yes Inspection Complete Complete Reinspection Incomplete Passed No No No No No Complete Thursday, June 10, 2021 Page 2 of 3 ·-------- Building Permit Inspection History Finaled (city of Carlsbad $!• • M <$;"+L'0:\B ,,,,-y. r "J.£lt:4~ ~ c, J • ~ · RISRMiT 1Nse,h-rtl&,,t11stolti1,r.CCA~2=020"!021'1~ :· · · : Permit Type: BLDG-Associated Permit Residenti: Application Date: 12/01/2020 Owner: LENNAR HOMES OF CALIFORNIA INC Work Class: Condo Issue Date: 12/16/2020 Subdivision: Status: Closed -Finaled Expiration Date: 09/28/2021 Address: 1893 ARTEMISIA CT IVR Number: 30545 CARLSBAD, CA 92011 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 01/0412021 01/04/2021 BLDG-21 147380-2020 Passed Paul Burnette Complete U ndergro u nd/U nderf lo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes NOTES Created By TEXT Created Date Paul Burnette Video inspection 01/04/2021 BLOG-22 Sewer/Water 147381-2020 Passed Pau I Burnette Complete Service Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/21/2021 01/21/2021 BLDG-11 148807-2021 Passed Chris Renfro Complete Foundatlon/Ftg/Plers (Robar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-12 Stool/Bond 148808-2021 Passed Chris Renfro Complete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 02/17/2021 02/17/2021 BLDG-14 150721-2021 Partial Pass Chris Renfro Reinspectlon Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency 2nd story deck nailing Yes 03/02/2021 03/02/2021 BLDG-15 Roof/ReRoof 151750-2021 Passed Paul Burnette Complete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03/22/2021 03/22/2021 BLDG-13 Shear 153214-2021 Passed Paul Burnette Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03/25/2021 03/2512021 BLDG-84 Rough 153544-2021 Passed Paul Burnette Complete Combo(14,24,34,44) Thursday, June 10, 2021 Page 1 of 3 . ' L • Southwest Inspection and Testing, Inc. 441 Commercial Way, La Habra, Ca 90831 (562) 941-2990 • (714) 528-8441 • Fax (582) 948-0028 REGISTERED INSPECTOR/AC! TECHNICIAN DAILY REPORT I SWIT Job No. I Date/ /'/. I Q,A I Cl I I T I ? I TYPE OF U. Reinforced Concrete U Welding U DINEfl<lxy ' INSPECTION ~ Post Tensioned Concrete D Fireproofing D Wood Framing REQUIRED Reinforced Masonry 0 Asphall n Other Job Address • H -~ ~--- Tract No. I Phaoa Lot~ I -, . . J -• tel Job Name ....,-17.,'-I' I,<.~• Penn~ L ---IHuad By Type of Structure .c...,--1_r-Archllect ·-/ . Material Description (type, grade, sourai) Engineer ,,. ,...,, ,. /I .,. ~-.·-.,._\/40_-,("_ . '• A•• Contractor ' II!!!... -I A A ~Ir Inspector's Name fZ /\' I, .. ' . Subcontractor / ;;-T ..., TESTS PERFORMED SAMPLE AIR CONC WATER TIME SET# TRUCK# TICKET# LOCATION SLUMP TEMP TEMP ADDED CAST MIX# REMARKS INSPECTION SUMMARY4.OCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT. AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'S OF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS ""ELD MADE H.T. BOLTS TORQUED' CHECKED ETC. ~--.,,_ -----£',, -.. __.., --, . L.A-..., • -· • ,... ,,,l -Pt. A ---• ------~F 1--ri., tA,<" ,/ _v,._,. ~ ~ ", ..c.-. --( ~--, .. _ . _,, ... • 1 • .,.,, r>,. . -~ ~ !:, -, , -rlf-loz #'1.0-.:... ~ 1 O '-t ~ ~,;:, -C:- *ie-r "'1"'"' U\ L f"..c. , .,.... "" A,6-- . ._ . ff. I ,,-, I -~ - .$,/ '7 ...... 't....A.,£_S. e,,·--"'--. .,. .... ~ I , " ( I' e:,,e ? 0 ""' ., -'\ , .--, rr ~ l :z:, "2 I g,,~-, A I? _<f"'~. -. -I ~ , A ,, ~-/ •071c, 1FLO~ . i .g._ "' ~ -If; r,;;,, ,, V • ., • ~ i >. ,_J { c;l) _ae, I S "T I " .. * o ~ I Z <)711_ / A ,~ ,.=~ . ,e-, "2', H e c.1 ~ • " ~ ~ 1~ IA( -/<201 " .. ft o?:-1 '-1 • 1~ I F'lJ , 2-,-, • I fl'a'7 1S . □ ov CONTINUED ON NEXT PAGE PAGE ' CERTIFICATION OF COMPLIANCE TIMEIN I HEREBY CERTIFY THAT I HAVE OBSERVED TO ntE BEST OF MY KNOWLEDGE ALL OF THE ABOVE R D WORK UNLESS OTHERWISE NOTED. I HAVE TIMEOUT SAMPLES FOUND THIS W PLY WITH THE APPROVED PLANS, SPECIFICATION, AND APPL E ION OF THE GO G GLAWS. Approved By Project Superintendent White-Office Copy• Canary-Accoun6ng Copy• Pink-Inspector's copy• Goldenrod-Jobsite Copy 0"'~~ C . "IE . -~s . tvJ ngmeenng • 11rvey111g Certified: SDVOSB • DVBE • SBE • CPUC January 21, 2021 J.N. 14-1018-1 City of Carlsbad Building Department Attn: City of Carlsbad -Building Department 1635 Faraday Avenue Carlsbad, CA 92008 RE: Poinsettia 61-Form Certifications for Units 102 through 107 CT 14-10, Map No. 16329 City of Carlsbad Building Department, GO/ay Based upon topographic surveys performed by 0' Day Consultants on January 13, 2021 for Units I 02 through I 07, the foundation forms for land development have been completed within standard tolerance (0.10 feet) in accordance with the approved plan, (City of Carlsbad DWG. 507-2C) O' Day Consultants Inc. O'DAY CONSULTANTS, INC. Very truly yours, /4.-,UJ:J'o/ George O'Day / Project Manager 2710 Coker Avenue West, Suite 100 Carlsbad, California 92010-6609 E-mail: oday@odayconsultants.com Website: www.odayconsultants.com Tel: 760.931.7700 Fax: 760,931.8680 G:\ 141018\Sl!fVey\FvrmCerts\ 141 SA-EXHB-FormCert_ 102-107.doc CiRCUP CELT~ 9245 Activity Rd., Ste. 103 San Diego, CA 92126 Tel: (858) 536-1000 Project Name: Poinsettia 61 Development Project No.: SD412B Project Location: Poinsettia Lane, Carlsbad, CA Client: Lennar Homes of California Contractor: Hermanos Construction Group Delta PM: Taylor Latimer, PE TYPE OF WORK PERFORMED Soils I Earthwork EQUIPMENT USED BY CONTRACTOR(S) Backhoe DESCRIPTION OF WORK PERFORMED Location of Work: Aisle "R" -Lot #s 102, 103, 104, 105, 106, & 107 Daily Field Report Date: 1/13/21 , Wed Weather: Sunny Start Time: 9:00 AM Lunch Time: n/a End Time: 12:00 PM Total Hours: 2 Work Performed: On site as requested to conduct inspection of footing subgrades at the above mentioned locations. Footing excavations were completed prior to arrival on site. Soils appeared to have been sufficiently moisture conditioned. Footing subgrade soil was examined using a soils probe and was found to be generally firm and unyielding. Accepted By: Submitted By: Signature: Signature: Name: Rick Kuzyk Name: Jonathan Davis Title: Site Superintendent Certification: ICC# 5236421 Representing (Company): Lennar Homes Group Delta Consultants, Inc. Page 1 of 2 DFR v 2018.03 l::iRCUPCELT.A 9245 Activity Rd., Ste. 103 San Diego, CA 92126 Tel: (858) 536-1000 DESCRIPTION (CONTINUED) SD4128 Poinsettia 61 Development Page 2 of 2 Daily Field Report 1 /13/21, Wed l Jonathan Davis A GR □UP DEL T.A FIELD MEMO l DATE: 1/13/2021 DAY: Wednesday PROJECT NAME: Poinsettia 61 Development CLIENT: Lennar 9245 Activity Road, Suite 103 San Diego, CA 92126 Tel. (858) 536-1000 Fax (858) 536-8311 Page 1 of 1 PROJECT NUMBER: SD412B MEMO BY: Jonathan Davis, ICC#S236421 SUBJECT: Foundation Excavation Observation Homesite No. Address Permit No. Plan Revision/Notes 102 1897 Aremisia Ct. CBRA2020-210 2-AltA 103 1893 Aremisia Ct. CBRA2020-211 3B 104 1889 Aremisia Ct. CBRA2020-212 4YA 104 1891 Aremisia Ct. (ADU} CBRA2020-216 4YA 105 1885 Aremisia Ct. CBRA2020-213 IA 106 1881 Aremisia Ct. CBRA2020-214 3C 107 1877 Aremisla ct. CBRA2020-215 2-AltB Reference: Gouvis Engineering (2018). Post-Tension Foundation Plans and Details for Treviso, Sheets SN-1 to 5D-3 (16 Sheets), dated August 24. Geotechnical Report: Report of Geotechnical Investigation, Poinsettia 61 Development Carlsbad, California Project No. 5D412, dated November 20, 2014 The referenced PT foundation excavations (described above, pictured below) exposed competent compacted fill. The bearing conditions exposed are consistent with the conditions anticipated in the referenced geotechnical investigation report and the Post Tension (PT) Model Home Plan Revjew. The foundation bearing soils appear to have a low expansion potential, and are considered suitable for the support of the proposed structure. The foundation dimensions meet the minimum geotechnical depth and width requirements. The dimensions per the referenced foundation plan are to be verified by others. The PT Slab subgrade contains numerous shallow plumbing trenches. Proper jetting techniques appear to have been used to provide consolidation NOTE: Footings should be deaned of loose and deleterious material prior to placing concrete. FOR GROUP DELTA INCORPORATED, BY: Jonathan Davis SIGNATURE: .... ~~ ISO 17025 5/12/15 rev1s1on 2