Loading...
HomeMy WebLinkAbout1889 ARTEMISIA CT; ; CBRA2020-0212; PermitBuilding Permit Finaled (city of Carlsbad Residential Associated Permit Print Date: 06/10/2021 Job Address: 1889 ARTEMISIA CT, CARLSBAD, CA 92011 Permit Type: BLDG-Associated Permit Residential Work Class: Parcel#: 2150530142 Track#: Valuation: $363,834.34 Lot#: Occupancy Group: #of Dwelling Units: 1 Project#: Plan#: Bedrooms: Construction Type: Condo CT140010 104 DEV14060 Bathrooms: Occupant Load: 4 3.0 Orig. Plan Check#: PC2020-0009 Plan Check#: PC2020-0050 Code Edition: Sprinkled: Project Title: POINSETTIA 61 Permit No: CBRA2020-0212 Status: Applied: Issued: Fina led Close Out: Inspector: Final Inspection: Closed -Finaled 12/01/2020 12/29/2020 PBurn 06/10/2021 Description: POINSETTIA 61 (TREVISO): PHASE 14 / LOT 104 / PLAN 4 / 2,288 LIVING/ 420 SF GARAGE/ 62 SF PATIO (ADU PER CBRA2020-0216) Applicant: Property Owner: LENNAR COMMUNITIES INC ALAN CHIK 25 ENTERPRISE, # 400 ALISO VIEJO, CA 92656-2708 (949) 204-4628 LENNAR HOMES OF CALIFORNIA INC 15131 ALTON PKWY, # UNIT 365 IRVINE, CA 92618-2385 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) (949) 204-4628 COMMUNITY FACILITIES DISTRICT (CFO) FEE -RES ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PARK IN-LIEU FEES SF DETACHED & DUPLEX: SW PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFD 5B1473 GREEN BUILDING STATE STANDARDS FEE SEWER BENEFIT AREA FEES -J SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG TRAFFIC IMPACT Residential Condo Outside CFD Total Fees: $32,482.44 Total Payments To Date: Building Division $32,482.44 Contractor: LENNAR HOMES OF CALIFORNIA INC 15131 ALTON PKWY, # UNIT 365 IRVINE, CA 92618-2385 (949) 204-4628 Balance Due: AMOUNT $1,563.20 $1,006.70 $3,617.04 $66.00 $175.00 $92.00 $5,728.00 $182.00 $12,734.20 $15.00 $2,112.00 $998.00 $47.30 $246.00 $3,900.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov ···~-----•.---~----·------ Permit Type: BLDG-Associated Permit Residenti, Application Date: 12/01/2020 Owner: LENNAR HOMES OF CALIFORNIA INC Work Class: Condo Issue Date: 12/29/2020 Subdivision: Status· Closed -Finaled Expiration Date: 10/04/2021 Address: 1889 ARTEMISIA CT IVR Number: 30546 CARLSBAD, CA 92011 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03/29/2021 03/29/2021 BLDG-84 Rough 153737-2021 Passed Paul Burnette Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 04/07/2021 04/07/2021 BLDG-17 Interior 154418-2021 Passed Paul Burnette Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-18 Exterior 154416-2021 Passed Paul Burnette Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-23 154417-2021 Passed Paul Burnette Complete Gas/Test/Repairs Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 05/07/2021 05/07/2021 BLDG-Electric Meter 156871-2021 Passed Paul Burnette Complete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/10/2021 06/10/2021 BLDG-Final Inspection 159417-2021 Passed Chris Renfro Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Thursday, June 10, 2021 Page 2 of 2 Building Permit Inspection History Finaled (city of Carlsbad Permit Type: BLDG-Associated Permit Residenti: Application Date: 12/01/2020 Owner: LENNAR HOMES OF CALIFORNIA INC Work Class: Condo Issue Date: 12/29/2020 Subdivision: Status: Closed -Finaled Expiration Date: 10/04/2021 Address: 1889 ARTEMISIA CT IVR Number: 30546 CARLSBAD, CA 92011 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 01/0412021 01/04/2021 BLDG-21 147384-2020 Passed Paul Burnette Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes NOTES Created By TEXT Created Date Paul Burnette Video inspection 01/04/2021 BLDG·22 Sewer/Water 147385-2020 Passed Paul Burnette Complete Service Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01121/2021 0112112021 BLDG-11 148809-2021 Passed Chris Renfro Complete Foundatlon/Ftg/Plers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-12 Steel/Bond 148810-2021 Passed Chris Renfro Complete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 0211712021 0211712021 BLDG-14 150722-2021 Partial Pass Chris Renfro Relnspectlon Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency 2nd story deck nailing Yes 0310212021 0310212021 BLDG-15 Roof/ReRoof 161752-2021 Passed Paul Burnette Complete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03/2212021 03/2212021 BLDG-13 Shear 153215-2021 Failed Paul Burnette Relnspectlon Incomplete Panels/HD {ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 03/23/2021 03123/2021 BLDG-13 Shear 153327-2021 Passed Paul Burnette Complete Panels/HD (ok to wrap) Thursday, June 10, 2021 Page 1 of 2 Southwest Inspection and Testing, Inc. 441 Commercial Way, La Habra, Ca 90831 (562) 941-2990 • (714) 528-8441 • Fax (562) 948-0026 REGISTERED INSPECTOR/ACI TECHNICIAN DAILY REPORT TYPE OF INSPECTION REQUIRED Job Address Job Name Reinforced Concrete iX_ Post Tensioned Concrete D · Reinforced Masonry Welding Do Fireproofing Asphalt Tract No. Penni TESTS PERFORMED AIR CONC WATER TIME SET# TRUCK# TICKET# SAMPLE LOCATION SLUMP TEMP TEMP ADDED CAST MIX# INSPECTION SUMMARY-l.OCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT· AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'S OF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS ELD MADE H.T. BOLTS TORQUED CHECKED ETC . V .. ., .. " " .. .. ,, " CERTIFICATION OF COMPLIANCE CONTINUED ON NEXT PAGE □ PAGE J or{ I HEREBY CERTIFY THAT I HAVE OBSERVED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE R D WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS W Y WITH THE APPROVED PLANS. SPECIFICATION, AND APPL N F THE GO G G LAWS. TIMEIN TIMEOUT SAMPLES Approved By Project Superlntet Iden! White _ Office Copy • Canary-Accounting Copy • Pink -Inspector's Copy • Goldenrod -Jobslte Copy ' 0"~~.-+1 C . ·1£ · · ~s~ · wt ngmeermg • urveymg Certified: SDVOSB • DVBE • SBE • CPUC January 21, 2021 J.N. 14-101 8-1 City of Carlsbad Building Department Attn: City of Carlsbad -Building Department 1635 Faraday Avenue Carlsbad, CA 92008 RE: Poinsettia 61-Form Certifications for Units 102 through 107 CT 14-10, Map No. 16329 City of Carlsbad Building Department, GOiay Based upon topographic surveys perfonned by 0' Day Consultants on January 13, 2021 for Units 102 through 107, the foundation forms for land development have been completed within standard tolerance (0.10 feet) in accordance with the approved plan, (City of Carlsbad DWG. 507-2C) O' Day Consultants Inc. O'DAY CONSULTANTS, INC. Very truly yours, h=r--o~/ George O'Day Project Manager 2710 Coker Avenue West, Suite 100 Carlsbad, California 92010-6609 E-mail: oday@odayconsultants.com Website: www.odayconsultants.com Tel: 760.931.7700 Fax: 760.931.8680 G:\ 141018\Survey\FormCerls\ 1418A-EXH8-FormCert_ 102-107. doc GRCUP DEL T.l\ 9245 Activity Rd., Ste. 103 San Diego, CA 92126 Tel: (858) 536-1000 Project Name: Poinsettia 61 Development Project No.: SD412B Project Location: Poinsettia Lane, Carlsbad, CA Client: Lennar Homes of California Contractor: Hermanos Construction Group Delta PM: Taylor Latimer, PE TYPE OF WORK PERFORMED Soils I Earthwork EQUIPMENT USED BY CONTRACTOR{S) Backhoe DESCRIPTION OF WORK PERFORMED Location of Work: Aisle "R" -Lot #s 102, 103, 104, 105, 106, & 107 Daily Field Report Date: 1/13/21, Wed Weather: Sunny Start Time: 9:00 AM Lunch Time: n/a End Time: 12:00 PM Total Hours: 2 Work Performed: On site as requested to conduct inspection of footing subgrades at the above mentioned locations. Footing excavations were completed prior to arrival on site. Soils appeared to have been sufficiently moisture conditioned. Footing subgrade soil was examined using a soils probe and was found to be generally firm and unyielding. Accepted By: Submitted By: Signature: Signature: Name: Rick Kuzyk Name: Jonathan Davis Title: Site Superintendent Certification: ICC# 5236421 Representing (Company): Lennar Homes Group Delta Consultants, Inc. Page 1 of 2 DFR v 2018.03 13RCUP CELT.A 9245 Activity Rd., Ste. 103 San Diego, CA 92126 Tel: (858) 536-1000 DESCRIPTION (CONTINUED) SD412B Poinsettia 61 Development Page 2 of 2 Daily Field Report 1/13/21, Wed j Jonathan Davis A GR □UP DEL T~ FIELD MEMO DATE: 1/13/2021 DAY: Wednesday PROJECT NAME: Poinsettia 61 Development CLIENT: Lennar 9245 Activity Road, Suite 103 San Diego, CA 92126 Tel. (858) 536-1000 Fax (858) 536-8311 IPagelofl PROJECT NUMBER: 5D412B MEMO BY: Jonathan Davis, ICC#5236421 SUBJECT: Foundation Excavation Observation Homesite No. Address Permit No. Plan Revision/Notes 102 1897 Aremisia Ct. CBRA2020-210 2-AltA 103 1893 Aremisia Ct. CBRA2020-211 3B 104 1889 Aremisia Ct. CBRA2020-212 4YA 104 1891 Aremisia Ct. (ADU) CBRA2020-216 4YA 105 1885 Aremisia Ct. CBRA2020-213 IA 106 1881 Aremisia Ct. CBRA2020-214 3C 107 1877 Aremisia Ct. CBRA2020-215 2-Alt B Reference: Gouvis Engineering (2018). Post-Tension Foundation Plans and Details for Treviso, Sheets SN-1 to SD-3 (16 Sheets), dated August 24. Geotechnical Report: Report of Geotechnical Investigation, Poinsettia 61 Development Carlsbad, California Project No. 5D412, dated November 20, 2014 The referenced PT foundation excavations (described above, pictured below) exposed competent compacted fill. The bearing conditions exposed are consistent with the conditions anticipated in the referenced geotechnical investigation report and the Post Tension (PT) Model Home Plan Review. The foundation bearing soils appear to have a low expansion potential, and are considered suitable for the support of the proposed structure. The foundation dimensions meet the minimum geotechnical depth and width requirements. The dimensions per the referenced foundation plan are to be verified by others. The PT Slab subgrade contains numerous shallow plumbing trenches. Proper jetting techniques appear to have been used to provide consolidation NOTE: Footings should be cleaned of loose and deleterious material prior to placing concrete. FOR GROUP DELTA INCORPORATED, BY: Jonathan Davis SIGNATURE: -~-··"-" ISO 17025 5/12/15 rev1s1on 2