HomeMy WebLinkAbout2616 ARGONAUTA ST; ; CBR2020-0801; PermitBuilding Permit Finaled
Residential Permit
Print Date: 05/07/2021
Job Address: 2616 ARGONAUTA ST, CARLSBAD, CA 92009-6501
Permit Type: BLDG-Residential Work Class:
Parcel#: 2154600800 Track#:
Valuation: $34,138.34 Lot#:
Occupancy Group:
#of Dwelling Units: 1
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition:
Sprinkled:
Project Title:
Project#:
Plan#:
Construction Type:
Orig. Plan Check#:
Plan Check #:
Description: CONVERT 734 SF GARAGE TO ADU
Applicant:
REYHANE BASSAMTABAR
763 2ND ST
ENCINITAS, CA 92024-4481
(413) 847-1541
FEE
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Property Owner:
SARA MOUSAVI
2614 ARGONAUTA ST
CARLSBAD, CA 92009-6501
(860) 328-1704
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
Second Dwelling Unit
Total Fees: $853.44 Total Payments To Date: $853.44
(city of
Carlsbad
Permit No: CBR2020-0801
Status:
Applied:
Issued:
Fina led Close Out:
Inspector:
Final Inspection:
Balance Due:
Closed -Finaled
04/14/2020
09/01/2020
PDrei
05/07/2021
AMOUNT
$310.00
$217.00
$41.00
$175.00
$42.00
$62.00
$2.00
$4.44
$0.00
Please take NOTICE that approval of your project includes the "lmposition11 of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
{cicyof
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
Plan Check CAA2.02Q-QOOI
Est. Value 3':\, l?>'c
PC Deposit ---------
Date 04/14/2020
~I.P Job Address ::Ill:= Argonauta St. Carlsbad, CA 92009 Suite: ____ APN: 215-460-08-00
CT/Project#: __________________ Lot #:_72_5 __ _
Fire Sprinklers: OYES 0 NO Air Conditioning: 0 YES ONO Electrical Panel Upgrade: 0 YES 0 NO
BRIEF DESCRIPTION OF WORK: The existing garage will be converted to a living space. A kitchen, closet and bathroom will be added.
Three parking doors will be demolished, one regular door with sidelights and two windows will be added to that wall.
0 Addition/New: _____ Living SF, ____ Deck SF, ____ Patio SF, ____ Garage SF
Is this to create an Accessory Dwelling Unit? 0 YON New Fireplace? 0 YON, if yes how many? __
[Z] Remodel: _7_3_4 ___ SF of affected area Is the area a conversion or change of use ? 0 Y ON
0 Pool/Spa: ____ SF Additional Gas or Electrical Features? _____________ _
□solar: ___ KW, __ Modules, Mounted:O Roof OGround, Tilt: 0 YO N, RMA: 0 YON,
Battery:OY ON, Panel Upgrade: Ov ON
D Reroof: ---------------------------------
□ Plumbing/Mechanical/Electrical Only: _______________________ _
D Other: _________________________________ _
APPLICANT (PRIMARY CONTACT)
Name: Reyhane Bassamtabar
Address: 763 2nd St.
City: Encinitas,
Phone: 4138471541
State:_C_A __ .Zip: 92024
Email: reyhane.basam@gmail.com
DESIGN PROFESSIONAL
Name: __________________ _
Address: _________________ _
City: ________ State: ___ .Zip: ___ _
Phone: _________________ _
Email: __________________ _
Architect State License: ___________ _
PROPERTY OWNER
Name: Sara S. Mousavi
Address: 2614 Argonauta St.
City: Carlsbad
Phone: 8603281704
State:_C_A __ ,Zip: 92009
Email: sara.sharifmousavi@gmail.com
CQ(IITRACTOR BUSINESS
Na~..:,,..,._ ________________ _
Address: _S_·-:.:...---------------
City: '::::::,_ State: Zip:
Phone:------"--''""·.._-:::::~---~~~~~~~~~~~~~-
Email: ________ _:::....,. ________ _
State license: ______ Bus. Li se: ______ _
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any stru re, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law
{Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500)).
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
8-1 Page 1 of 2 Rev. 06/18
( OPTION A): WORKERS'COMPENSATION DECLARATION:
I hearby affirm under penalty of perjury QM_ of the following declarations: 01 have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued.
0 I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: Insurance Company Name: _____________________ _
Policy No. ______________ Expiration Date: _________ _
0 Certificate of EKempt/on: I certify that in the performance of the work for which this permit is issued, f shalt not employ any person in any manner so as to be come
subject to the workers' compensation laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for In Section 3706 of the labor Code,
interest and attorney's fees.
CONTRACTOR SIGNATURE: □AGENT DATE: -----------------------------
( OPTION B ): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
DI, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work
himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
C:3.!, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0 I am exempt under Section ____ --,-___ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. QYES Q NO
2. I (have/ have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/
contractors' license number):
5. twill provide some of the work, but I have contracted {hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work):
ow,n """"""'' ~ o..,., "'""
CONSTRUCTION LENDING ENCY :IF ANY: '
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name: ____________________ _ Lender's Address: ____________________ _
ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes/ No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes / No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes / No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction.
thereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE CITY OF CARLSBAD AGAINST ALLUABIUTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CllY IN CONSEQUENCE OF
THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations overS'O' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized
by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time
after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Buildin~
APPLICANT SIGNATURE: ~ ~ DATE: _______ _
1635 Faraday Ave Carlsbad, CA 92008
B-1
Ph: 760-602-2~ax: 760-602-8558 t/
Page 2 of 2
Email: Building@carlsbadca.gov
Rev. 06/18
Permit Type: BLDG-Residential
Work Class: Second Dwelling Unit
Status:
Scheduled
Date
Closed -Finaled
Actual Inspection Type
Start Date
BLDG-Electrical Final
Friday, May 7, 2021
Application Date: 04/14/2020 Owner: SARA MOUSAVI
Issue Date: 09/01/2020
Expiration Date: 07/19/2021
Subdivision: LA COSTA MEADOWS #4
Address: 2616 ARGONAUTA ST
IVR Number: 25899 CARLSBAD, CA 92009-6501
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
May 7, 2021: (Virtual inspection).
No final garage conversion To habitable
living space/Building deficiencies.
1. Heating unit/system required to be
installed-approved.
2. Electrical, plumbing, and mechanical
corrections addressed and scope of
garage conversion to habitable living space
work completed and approved.
3. Exterior (T/R, W/R), exterior bubble
cover receptacles installed securely at two
outside locations-approved.
4. Drywall openings around two receptacle
locations, silicone caulking sealed all small
openings at backside of new electrical
receptacles.
5. Rest of garage conversion/remodel to
habitable condition space, scope of work,
including existing driveway retrofit with
new•drain system to capture water.sheet
flow, from sloped driveway, redirect water
away from new habitable living, garage
conversion, addition space•inspected and
approved.
Yes
Page 10 of 10
Permit Type: BLDG-Residential
Work Class: Second Dwelling Unit
Status:
Scheduled
Date
Closed -Finaled
Actual Inspection Type
Start Date
BLDG-Structural Final
BLDG-Structural Final
Friday, May 7, 2021
Application Date: 04/14/2020
Issue Date: 09/01/2020
Expiration Date: 07/19/2021
IVR Number: 25899
Owner: SARA MOUSAVI
Subdivision: LA COSTA MEADOWS #4
Address: 2616 ARGONAUTA ST
CARLSBAD, CA 92009-6501
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
February 16, 2021:
Building deficiencies
1. Heating uniUsystem required to be
installed-approved.
2. Electrical, plumbing, and mechanical
corrections addressed and minimal/minor
work to be completed.
3. Exterior (T/R, W/R), exterior bubble
cover receptacles not installed securely at
two outside locations.
4. Drywall openings around two receptacle
locations, need caulking and not allowing
openings to backside of new electrical
receptacles.
5. Rest of garage conversion/remodel to
habitable condition space, scope of
work-approved.
May 7, 2021: (Virtual inspection).
No final garage conversion To habitable
living space/Building deficiencies.
1. Heating uniUsystem required to be
installed-approved.
2. Electrical, plumbing, and mechanical
corrections addressed and scope of
garage conversion to habitable living space
work completed and approved.
3. Exterior (T/R, W/R), exterior bubble
cover receptacles installed securely at two
outside locations-approved.
4. Drywall openings around two receptacle
locations, silicone caulking sealed all small
openings at backside of new electrical
receptacles.
5. Rest of garage conversion/remodel to
habitable condition space, scope of work,
including existing driveway retrofit with
new-drain system to capture water-sheet
flow, from sloped driveway, redirect water
away from new habitable living, garage
conversion, addition space-inspected and
approved.
Yes
Yes
Page 9 of 10
Permit Type: BLDG-Residential
Work Class: Second Dwelling Unit
Status:
Scheduled
Date
Closed -Finaled
Actual Inspection Type
Start Date
Checklist Item
BLDG-Plumbing Final
BLDG-Mechanical Final
Friday, May 7, 2021
Application Date: 04/14/2020 Owner: SARA MOUSAVI
Issue Date: 09/01/2020
Expiration Date: 07/19/2021
IVR Number: 25899
Subdivision: LA COSTA MEADOWS #4
Address: 2616 ARGONAUTA ST
CARLSBAD, CA 92009-6501
Inspection No.
COMMENTS
Inspection
Status
May 7, 2021: (Virtual inspection).
Primary Inspector
No final garage conversion To habitable
living space/Building deficiencies.
1. Heating unit/system required to be
installed-approved.
2. Electrical, plumbing, and mechanical
corrections addressed and scope of
garage conversion to habitable living space
work completed and approved.
3. Exterior (T/R, W/R), exterior bubble
cover receptacles installed securely at two
outside locations-approved.
4. Drywall openings around two receptacle
locations, silicone caulking seated all small
openings at backside of new electrical
receptacles.
5. Rest of garage conversion/remodel to
habitable condition space, scope of work,
including existing driveway retrofit with
new-drain system to capture water-sheet
flow, from sloped driveway, redirect water
away from new habitable living, garage
conversion, addition space-inspected and
approved.
May 7, 2021: (Virtual inspection).
No final garage conversion To habitable
living space/Building deficiencies.
1. Heating uniVsystem required to be
installed-approved.
2. Electrical, plumbing, and mechanical
corrections addressed and scope of
garage conversion to habitable living space
work completed and approved.
3. Exterior (T/R, W/R), exterior bubble
cover receptacles installed securely at two
outside locations-approved.
4. Drywall openings around two receptacle
locations, silicone caulking sealed all small
openings at backside of new electrical
receptacles.
5. Rest of garage conversion/remodel to
habitable condition space, scope of work,
including existing driveway retrofit with
new-drain system to capture water-sheet
flow, from sloped driveway, redirect water
away from new habitable living, garage
conversion, addition space-inspected and
approved.
Reinspection Inspection
Passed
Yes
Yes
Page 8 of 10
Permit Type: BLDG-Residential
Work Cl
0
ass: Second Dwelling Unit
Status;
Scheduled
Date
05/0712021
Closed -Finaled
Actual Inspection Type
Start Date
BLDG-Structural Final
BLDG-Electrical Final
05/07/2021 BLDG-Final Inspection
Friday, May 7, 2021
Application Date: 04/14/2020 Owner: SARA MOUSAVI
Issue Date: 09/01/2020 Subdivision: LA COSTA MEADOWS #4
Expiration Date: 07/19/2021
IVR Number: 25899
Address: 2616 ARGONAUTA ST
CARLSBAD, CA 92009-6501
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
February 16, 2021:
Building deficiencies
1. Heating uniVsystem required to be
installed-approved.
2. Electrical, plumbing, and mechanical
corrections addressed and minimal/minor
work to be completed.
3. Exterior (T/R, W/R), exterior bubble
cover receptacles not installed securely at
two outside locations.
4. Drywall openings around two receptacle
locations, need caulking and not allowing
openings to backside of new electrical
receptacles.
5. Rest of garage conversion/remodel to
habitable condition space, scope of
work-approved.
February 16, 2021:
Building deficiencies
1. Heating uniUsystem required to be
installed-approved.
2. Electrical, plumbing, and mechanical
corrections addressed and minimal/minor
work to be completed.
3. Exterior {T/R, W/R), exterior bubble
cover receptacles not installed securely at
two outside locations.
4. Drywall openings around two receptacle
locations, need caulking and not allowing
openings to backside of new electrical
receptacles.
5. Rest of garage conversion/remodel to
habitable condition space, scope of
work-approved.
156887-2021 Passed Tony Alvarado
Yes
Yes
Complete
Page 7 of 10
~ M -'M -~"0:9£z,,, -:::-,~ ?€ -, ' -/ti • M % o/ ;;""' '
•. .. 7 {:PERMIT;~tf8eciiliN1tt11JORYlaJi1.,J:1Bao~o.-:-da0:1J:· · · ~ .
Permit Type: BLDG-Residential
Work Class: Second Dwelling Unit
Status: Closed -Finaled
Application Date: 04/14/2020 Owner: SARA MOUSAVI
Issue Date: 09/01/2020 Subdivision: LA COSTA MEADOWS #4
Expiration Date: 07/19/2021
IVR Number: 25899
Address: 2616 ARGONAUTA ST
CARLSBAD, CA 92009-6501
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
Friday, May 7, 2021
COMMENTS
February 5, 2021:
Building deficiencies
1. Heating units required to be installed.
2. corrections need to be addressed on
back of permit card.
3. Electrical, plumbing, and mechanical
corrections need to be addressed.
February 16, 2021:
Building deficiencies
1. Heating uniVsystem required to be
installed-approved.
2. Electrical, plumbing, and mechanical
corrections addressed and minimal/minor
work to be completed.
3. Exterior (T/R, W/R), exterior bubble
cover receptacles not installed securely at
two outside locations.
4. Drywall openings around two receptacle
locations, need caulking and not allowing
openings to backside of new electrical
receptacles.
5. Rest of garage conversion/remodel to
habitable condition space, scope of
work-approved.
February 16, 2021:
Building deficiencies
1. Heating uniUsystem required to be
installed-approved.
2. Electrical, plumbing, and mechanical
corrections addressed and minimal/minor
work to be completed.
3. Exterior (T/R, W/R), exterior bubble
cover receptacles not installed securely at
two outside locations.
4. Drywall openings around two receptacle
locations, need caulking and not allowing
openings to backside of new electrical
receptacles.
5. Rest of garage conversion/remodel to
habitable condition space, scope of
work-approved.
Passed
No
Yes
Yes
Page 6 of 10
• ~ , _='::§;:" ~ __ :sJ'-::::,,4-10'-~ "' Al 7'1¾S,~;~t ' ," , ~
• • 0 : • ·;!PERMIT QISR&e~·-.:itttISlfrliillor (CBR2oio-:QSCX1l~::;,:-~ _, : .. :
Permit Type: BLDG-Residential
Work Class: Second Dwelling Unit
Status:
Scheduled
Date
Closed -Finaled
Actual Inspection Type
Start Date
Checklist Item
Application Date: 04/14/2020 Owner: SARA MOUSAVI
Issue Dato: 09/01/2020 Subdivision: LA COSTA MEADOWS #4
Expiration Date: 07/19/2021
IVR Number: 25899
Inspection No.
COMMENTS
Inspection
Status
Address: 2616 ARGONAUTA ST
CARLSBAD. CA 92009-6501
Primary Inspector Reinspection Inspection
Passed
BLDG-Building Deficiency February 5, 2021: No
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Electrical Final
02/1612021 02/1612021 BLDG-Final Inspection
Friday, May 7, 2021
Building deficiencies
1. Heating units required to be installed.
2. corrections need to be addressed on
back of permit card.
3. Electrical, plumbing, and mechanical
corrections need to be addressed.
February 5, 2021:
Building deficiencies
1. Heating units required to be installed.
2. corrections need to be addressed on
back of permit card.
3. Electrical, plumbing, and mechanical
corrections need to be addressed.
February 5, 2021:
Building deficiencies
1. Heating units required to be installed.
2. corrections need to be addressed on
back of permit card.
3. Electrical, plumbing, and mechanical
corrections need to be addressed.
February 5, 2021:
Building deficiencies
1. Heating units required to be installed.
2. corrections need to be addressed on
back of permit card.
3. Electrical, plumbing, and mechanical
corrections need to be addressed.
150609-2021 Partial Pass Tony Alvarado
No
No
No
Reinspectlon Incomplete
Page 5 of 10
Application Date: 04/14/2020 Owner: SARA MOUSAVI Permit Type: BLDG-Residential
Work Class: Second Dwelling Unit Issue Date: 09/01/2020 Subdivision: LA COSTA MEADOWS #4
Status:
Scheduled
Date
01/19/2021
02/0512021
Closed -Finaled Expiration Date: 07/19/2021
IVR Number: 25899
Address: 2616 ARGONAUTA ST
CARLSBAD, CA 92009-6501
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
01/19/2021
02/0512021
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
January 6, 2021:
1. Rough framing Inspection, for existing
(2) car garage conversion to a new ADU
Habitable space/living area, per
architectural/structural engineer's revised
plan details and specifications -approved.
2. Owner will provide two sets of revised
framing detailing, depicting exterior existing
garage door wall converted to new ADU
entry door wall, with new infilling framing,
and new stepped concrete curb-approved.
3. New plumbing waste and vent lines and
new electrical lines, scope of
work-approved.
4. New mechanical venting for new a DU
restroom and kitchenette-approved.
January 6, 2021:
1. Rough framing Inspection, for existing
(2) car garage conversion to a new ADU
Habitable space/living area, per
architectural/structural engineer's revised
plan details and specifications -approved.
2. Owner will provide two sets of revised
framing detailing, depicting exterior existing
garage door wall converted to new ADU
entry door wall, with new infilling framing,
and new stepped concrete curb-approved.
3. New plumbing waste and vent lines and
new electrical lines, scope of
work-approved.
4. New mechanical venting for new a DU
restroom and kitchenette-approved.
BLDG-17 Interior 148575-2021 Passed Paul Burnette
Lath/Drywall
Checklist Item COMMENTS
BLDG-Building Deficiency
NOTES Created By TEXT
Paul Burnette Video inspection
BLDG-Final Inspection 149838-2021 failed Tony Alvarado
Yes
Yes
Complete
Passed
Yes
Created Date
01/19/2021
Reinspection Incomplete
Friday, May 7, 2021 Page 4 of 10
~' fi ::--", -:!:"½,:Y,iff:P~ 0 r;q •~ ",~:;f: , ~ T': 1' X cd ~
· \;pERMIT INSREC!'f'Il>Jll§tll$"'C~R'f~Q,[ (CBR~Q20~Qao11.,._ . -
Permit Type: BLDG-Residential
Work Class: Second Dwelling Unit
Application Date: 04/14/2020 Owner: SARA MOUSAVI
Status: Closed -Finaled
Issue Date: 09/01/2020 Subdivision: LA COSTA MEADOWS #4
Expiration Date: 07/19/2021
IVR Number: 25899
Address: 2616 ARGONAUTA ST
CARLSBAD, CA 92009-6501
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
Friday, May 7, 2021
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
COMMENTS
Not ready, exterior flashing and weep
screed not installed properly. Exterior
sheathing not nailed/screwed properly.
Stud wall framing not 16"o.c. Per plan, no
plumbing, electrical, or mechanical
completed. Call for reinspection
January 6, 2021:
1. Rough framing Inspection, for existing
(2) car garage conversion to a new ADU
Habitable space/living area, per
architectural/structural engineer's revised
plan details and specifications -approved.
2. Owner will provide two sets of revised
framing detailing, depicting exterior existing
garage door wall converted to new ADU
entry door wall, with new infilling framing,
and new stepped concrete curb-approved.
3. New plumbing waste and vent lines and
new electrical lines, scope of
work-approved.
4. New mechanical venting for new a DU
restroom and kitchenette-approved.
5. Sound metal resilient channel (hat
channel), installed anchored/fastened
correctly-approved.
January 6, 2021:
1. Rough framing Inspection, for existing
(2) car garage conversion to a new ADU
Habitable space/living area, per
architectural/structural engineer's revised
plan details and specifications -approved.
2. Owner will provide two sets of revised
framing detailing, depicting exterior existing
garage door wall converted to new ADU
entry door wall, with new infilling framing,
and new stepped concrete curb-approved.
3. New plumbing waste and vent lines and
new electrical lines, scope of
work-approved.
4. New mechanical venting for new a DU
restroom and kitchenette-approved.
Passed
No
Yes
Yes
Page 3 of 10
Application Date: 04/14/2020 Owner: SARA MOUSAVI Permit Type: BLDG-Residential
Work Class: Second Dwelling Unit Issue Date: 09/01/2020 Subdivision: LA COSTA MEADOWS #4
Status:
Scheduled
Date
0110612021
Closed -Finaled Expiration Date: 07/19/2021
IVR Number: 25899
Address: 2616 ARGONAUTA ST
CARLSBAD, CA 92009-6501
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector Reinspection Inspection
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Top out
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
Status
COMMENTS
Not ready, exterior flashing and weep
screed not installed properly. Exterior
sheathing not nailed/screwed properly.
Stud wall framing not 16"o.c. Per plan, no
plumbing, electrical, or mechanical
completed. Call for reinspection
01106/2021 BLDG-84 Rough
Combo(14,24,34,44)
147618-2021 Passed Tony Alvarado
Passed
No
No
No
No
No
Complete
Friday, May 7, 2021 Page 2 of 10
Building Permit Inspection History Finaled
(city of
Carlsbad
Application Date: 04/14/2020 Owner: SARA MOUSA VI Permit Type: BLDG-Residential
Work Class: Second Dwelling Unit Issue Date: 09/01/2020 Subdivision: LA COSTA MEADOWS #4
Status: Closed -Finaled Expiration Date: 07/19/2021 Address: 2616 ARGONAUTA ST
CARLSBAD, CA 92009-6501 IVR Number: 25899
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection
Date Start Date Status
11/13/2020 1111312020 BLDG-14 143726-2020 Failed Peter Dreibelbis Reinspectlon
Frame/Steel/Boltlng/We
ldlng (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No one home at 12:10 No
11116/2020 11/1612020 BLDG-14 143828-2020 Failed Tony Alvarado Reinspection
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No one home at 12:10 No
November 16, 2020: no plans on site and
framing inspection failed. Spoke to owner
about pressure-treated sill plates required
at exterior walls and plans required on site.
11/18/2020 1111812020 BLDG-14 144068-2020 Failed Tony Alvarado Reinspectlon
Frame/Steel/BoltlnglWe
lding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No one home at 12:10 No
November 16, 2020: no plans on site and
framing inspection failed. Spoke to owner
about pressure-treated sill plates required
at exterior walls and plans required on site.
BLDG-Building Deficiency November 18, 2020: (inspection failed). No
1. Spoke to owner about pressure-treated
sill plates required at exterior walls and
plans do not add_ress pressure-treated
plates at front elevation.
3. finish exterior grade is same height as
interior finish floor living/dwelling finish
height level. No barrier or 8" concrete
stemwall, or flashing between exterior
finish level and interior dwelling/ADU finish
floor level.
1211712020 12/17/2020 BLDG-84 Rough 146500-2020 Failed Chris Renfro Reinspectlon
Combo(14,24,34,44)
Friday, May 7, 2021
Inspection
Incomplete
Incomplete
Incomplete
Incomplete
Page 1 of 10
✓• EsG1I
A SAFf.budt Colllpany
DATE: 5/20/2020
JURISDICTION: Carlsbad
PLAN CHECK#.: cbR2020-0801
PROJECT ADDRESS: 2616 Argonaula St.
PROJECT NAME: Remodel for an ADU
SET II
~PPLICANT
/ URIS.
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person. D The applicant's copy of the check list has been sent to:
~ EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted"ipo /2-0(b$W'6
Mail Telephone Fax In Person
0 REMARKS:
By: Richard Moreno
EsGil
5/12/2020
Telephone#:
Email:
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
✓• EsG1I
A SAFEbui!r Company
DATE: 4/24/2020
JURISDICTION: Carlsbad
PLAN CHECK#.: cbR2020-0801
PROJECT ADDRESS: 2616 Argonaula St.
PROJECT NAME: Remodel for an ADU
SETI
D APPLICANT
D JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
[8J The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
[8J The applicant's copy of the check list has been sent to:
Reyhane Bassamtabar
D EsGil staff did not advise the applicant that the plan check has been completed.
[8:l EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Reyhane Bassamtabar Telephone#: 413-847-1541
Date contacted: (by: ) Email: reyhane.basam@gmail.com
Mail Telephone Fax In Person
0 REMARKS:
By: Richard Moreno
EsGil
4/16/2020
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad cbR2020-0801
4/24/2020
a) All fans installed to meet all of the preceding ventilation requirements must
be specified at a noise rating of a maximum 1 "Sane" (continuous use) or
3 "Sane" (intermittent).
MISCELLANEOUS
26. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
27. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes □ No □
28. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Richard Moreno at EsGil. Thank you.
Carlsbad cbR2020-0801
4/24/2020
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: cbR2020-0801 JURISDICTION: Carlsbad
PROJECT ADDRESS: 2616 Argonaula St.
FLOOR AREA:
Remodel: 734 sq-ft
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 4/24/2020
FOREWORD (PLEASE READ):
STORIES: 2
HEIGHT: no change
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 4/16/2020
PLAN REVIEWER: Richard Moreno
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2019 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2018 IRC, 2018 IBC,
2018 UPC, 2018 UMC and 2017 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2018 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad cbR2020-0801
4/24/2020
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Richard Moreno
BUILDING ADDRESS: 2616 Argonaula St.
BUILDING OCCUPANCY:
PLAN CHECK#.: cbR2020-0801
DATE: 4/24/2020
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
remodel 734 citv est
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
..
1997 UBC Buildin Permit Fee g 'l• . .. J
1997 UBC Plan Check Fee
Type of Review:
D Repetitive Fee
~ Repeats
__-2.l
D Complete Review
D Other
D Hourly
EsGII Fee
Reg. VALUE ($)
Mod.
34,138
34,138
l
D Structural Only
1--------<1 Hr. @ * $201.821
comments: ll'.l{li!.ciciltit>r;ifgtneabqvefEie,arfadditicfos.lfeeof$ .··tsdUel .·····oour@
$. W<Jhri[{fQr'th~~~i~r~ijn>Pe~l~W. . . . . . . . .
Sheet of
Carlsbad cbR2020-0801
4/24/2020
PLANS
1. The following note should be given with each correction list
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil is complete.
2. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
3. Please indicate on the plans whether the existing residence has a fire sprinkler
system installed. If so, then provide a note stating that any additions/alterations
will be provided with an automatic residential fire sprinkler system. Section
R313.2.
4. Glazing in the following locations should be shown on the plans as safety glazing
material in accordance with Section R308.4:
a) Glazing in doors.
b) Glazing adjacent to a door where the bottom exposed edge of the glazing is
less than 60" above the walking surface. and it meets either of the following
conditions:
i) Where the glazing is within 24" of either side of the door in the plane
of the door in a closed position.
5. There shall be a landing or floor on each side of each exterior door. The width of
each landing shall be not less than the door served. Every landing shall have a
dimension of not less than 36 inches measured in the direction of travel. The
slope at exterior landings shall not exceed ¼ unit vertical in 12 units horizontal (2
percent). Landing shall be not more than 7-3/4 inches below the top of the
threshold. R311.3.
Carlsbad cbR2020-0801
4/24/2020
6. Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor--
ceilings and roof-ceilings shall be protected as required in CRC Section R302.4."
7. Walls and floors separating units in a duplex shall have a sound transmission
class (STC) of not less than 50. Additionally, floors must have an impact
insulation class (IIC) rating of not less than 50. CBC Section 1207. Show the
location of and provide details of the listed wall and floor/ceiling assemblies and
indicate the listing agency and listing number for the tested ratings.
8. Floor assemblies separating units in a duplex shall be of one-hour fire resistive
construction (½-hour if the building has an automatic sprinkler system). Provide
details of the assemblies. Section R302.3. Such assemblies shall extend to and
be tight to the exterior wall, where applicable.
9. Unless Garage is for the sole usage of ADU tenant, walls between garage and
ADU must be fire and sound rated.
10. The supporting construction of fire-rated floor assemblies shall have an equal or
greater fire-rating. Section R302.3.1.
PLUMBING
11. Show water heater size (1 st hour rating), type, and location on plans. Note: For
both new dwellings and additions the Energy Standards (150.0(n)) requires a gas
input rating of 200,000 Btu for both tank and instantaneous gas water heaters.
(Also) Provide a gas piping design for the gas system.
12. ADU must have access to either an existing accessible water heating appliance,
or its own independent appliance.
13. Show the T and P relief valve at the water heater and the discharge pipe size
and routing to the exterior. CPC Section 608.3.
ELECTRICAL
14. Show on the plan the amperage of the electrical service, the location of the
service panel and the location of any sub-panels. If the service is over 200
amperes, submit a single line diagram, panel schedules, and provide service
load calculations.
15. Note on the plans that receptacle outlet locations will comply with CEC Article
210.52.
16. A receptacle outlet must be installed in every kitchen, family room, dining room,
living room, sunroom, parlor, library, den, bedroom, recreation room, and similar
room or area so that no point along the wall space is more than 6 feet, measured
horizontally along the floor line, from a receptacle outlet CEC 210.52(A)
Carlsbad cbR2020-0801
4/24/2020
17. A balcony, deck, or porch that is accessible from the interior of the dwelling will
require a minimum of one receptacle outlet. CEC 210.52(E) (3). This receptacle
must be GFCI protected.
18. Show on the plans that countertop receptacle outlets comply with CEC Article
210.52(C): In kitchens a receptacle outlet shall be installed at each counter
space 12 inches or wider; Receptacles shall be installed so that no point along
the wall line is more than 24 inches; Island and peninsular countertops 12 inches
by 24" long (or greater) shall have at least one receptacle. (Counter top spaces
separated by range tops, refrigerators, or sinks shall be considered as separate
counter top spaces).
19. Per CEC Article 210.11 (C)1, note on the plans that there will be a minimum of 2
small appliance branch circuits within the locations specified in Article 210.52(8),
i.e., kitchen and dining areas.
20. Per CEC Article 210.11 (C)3, note on the plans that bathroom circuiting shall be
either:
a) A 20-ampere circuit dedicated to each bathroom, or
b) At least one 20 ampere circuit supplying only bathroom receptacle outlets.
21. An ADU may have a separate utility service installed, or sub fed via existing
service with adequate capacity. ADU's require electrical load calculations per CEC
220.83 to justify existing electrical service size is adequate.
ENERGY CONSERVATION
Residential ventilation requirements: ES 150.0(o)/ASHRAE 62.2
22. Kitchens require exhaust fans with a minimum 100 cfm ducted to the exterior.
Detail compliance by including a complying exhaust fan or a ducted range hood
to the exterior.
23. Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the exterior.
A bathroom is defined "as a room with a bathtub, shower, or spa or some similar
source of moisture".
24. Residential bathroom exhaust fans shall be energy star rated and shall be control
by a humidistat capable of an adjustment between 50 and 80% humidity.
CalGreen 4.506.1. Exception: Control by a humidistat is not required if the
bathroom exhaust fan is also the dwelling whole house ventilation.
25. Mechanical whole house ventilation must be provided. Identify the fan providing
the whole house ventilation (complete with CFM and Sane rating) on the
floorplans. For additions 1,000 square feet or less, whole house ventilation is not
required. For additions over 1,000 square feet, the whole house ventilation CFM
shall be based upon the entire (existing and addition) square footage, not just the
addition.
CERTIFICATION OF SCHOOL FEES PAID
c:ornpleted bY the City, the eppllcant, atld the appropriate school districts and returned to the Clt
11'1'$ form must Jt g permit. The City will not issue any bufldlng permit Without a completed $Choo! fee form. Y Prior to 1ss1.11n9 a r,ull n
Project# & Name:
Permit#:
project Address:
CBR2020-080l
2616 ARGONAUT A ST
Assessor's Parcel#; :.2:.:15::.:14~6.::::00:c8;.;:0;.::;.0 ____ ....... ......, _________ _
Project Applicant; .:::;SA:;.;;R:.;:A.;..M;.;,;_O..;:;U.;;.SA;..;.V.;,.;1 ____________ _
(Owner Name)
Residential Square Feet:
New/Additions:·--'-----------------
Second Dwelling Unit 734 (Convert garage to ADU)
Commercial Square Feet:
New/Additions: _________________ _
City Certification; City of Carlsbad Building Division Date: 07/07/2020
Certification of ApplicanVOWners. The person executing this declaration ("Owner") oertifi8/J
under penalty of perjury that (1) the Information provided above is correct and true to the
best of the Owner's knowledge, and that the OWner will file an amended certification of
payment and pay the additional fee if Owner requests an increase in the number of
dWelling units or square footage after the b1.11fdin9 pennit is issued or if the initial
determination of units or square footage is found to be incorrect, and that (2) the Owner is
the owner/developer of the above described project(s), or that the person executing this
declaration is authorized to sign on behalf of the Owner.
m Cart1bad UrlJfled School.,.....
6225 El Camino Real
Cartabad CA 92009
Phone: (760) 331-!S<IOO
[ii Enclnltfl Union IOMol ..._
101 SouthRanc::hoSamclFe,W
Encinitaa, CA 92024
Phone: (700) 944-4300 ,rt 'tel
•• San Diegulto Union HJt. ......
684 Requeza Or.
Enclnitat, CA 92024
Phone: (760) 753-6491 EJCt 551-4
(By Appl Only)
• s.n Marco. Unified lcb.
255 Pico Ave Ste. 100
San Marcos, CA 92089
Ph<>ne: (760) 290-2849
Contact: Katherine Marcella
(By Appt.only)
• Vista Unified School Mdrtcl
1234 Arcadia Drive
Vista CA 92083
PhOne: {760) 726-2170 ~
SCHOOL DISTRICT SCHOOL FEE CERTIFICATION
(To be completed by the school district(•))
THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIRl:t«N
FOR THE PROJECT HAVE BEEN OR WILL BE SATISFI&D.
• • . • • • . • • • I
Title:
Name of School District:
Ccityof
Carlsbad
PURPOSE
CLIMATE ACTION PLAN
CONSISTENCY CHECKLIST
B-50
Development Services
Building Division
1635 Faraday Avenue
(760) 602-2719
www.carlsbadca.gov
This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance
requirements apply to their projects. The completed checklist must be included in the building permit application. It may be
necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate
full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach
to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as
specified by the ordinances.
NOTE: The following type of permits are not required to fill out this form
❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool
All If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance,
an explanation must be provided to the satisfaction of the Building Official.
..i1 Details on CAP ordinance requirements are available on the city's website.
All A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be
completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and
download the latest form.
Project Name/Building
Permit No.: Mousavi ADU BPNo.:Cf;)R2.020-Qc()I
-------------------
Property Address/APN: 215-460-08-00
Applicant Name/Co.: Reyhane Bassamtabar
Applicant Address: 763 2nd St. Encinitas, CA 92024
Contact Phone: 41384 71541 Contact Email: reyhane.basam@gmail.com
Contact information of person completing this checklist (if different than above):
Name:
Company
name/address:
Reyhane Bassamtabar Contact Phone:
763 2nd St, Contact Email:
4138471541
reyhane.basam@gmail.com
Applicant Signature:--------/ ________ Date: 4/13/2020
Encin~::A 92024
f.f:?
B-50 Page 1 of 6 Revised 08/19
City of Carlsbad Climate Action Plan Consistency Checklist
Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project.
For alterations and additions to existing buildings, attach Building Permit Valuation worksheet.
Building Permit Valuation (BPV) from worksheet: $ ______ _
Con1t111ctlon Type
0 Residential
□ New construction
□ Additions and alterations:
□ BPV < $60,000
□ BPV ~ $60,000
□ Electrical service panel upgrade only
□ BPV ~ $200,000
D Nonresidential '
□ New construction
□ Alterations:
□ BPV ~ $200,000 or additions~ 1,000
square feet
□ BPV ~ $1,000,000
□ ~ 2,000 sq. ft. new roof addition
Checkllat Item
Complete Sectlon(a) Note&:
A high-rise residential building is 4 or more stories, including a
Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor
area is residential use
2A, 3A, 18, 2B,
4A 38,4A
NIA NIA All residential additions and alterations
1A, 4A 4A 1-2 family dwellings and townhouses with attached garages
only
*Multi-family dwellings only where interior finishes are removed
1A, 4A* 18, 4A* and significant site work and upgrades to structural and
mechanical, electrical, and/or plumbing systems are proposed
18, 28, 38, 48 and 5
18,5
18, 28, 5 Building alterations of~ 75% existing gross floor area
28,5 18 also applies if BPV ~ $200,000
Check the appropriate boxes, e)(plain all not applicable and exception Items, and provide supporting calw ations and documentatton as necessary.
1. Energy Efficiency
Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for
more information when completing this section.
A D Residential addition or alteration :2: $60,000 building permit valuation.
See CMC section 18.30.190.
Year Built Single-family Requirements
□ Before 1978 Select one:
□ Duct sealing □ Attic insulation □Cool roof
□ 1978 and later Select one:
□ Lighting package □ Water heating Package
0 Between 1978 and 1991
□ 1992 and later
□ NIA. _________ _
□ Exception: Home energy score i! 7
(attach certification)
Multi-family Requirements
□ Attic insulation
Select one:
□ Duct sealino □ Attic insulation □Cool roof
Select one:
□ Lighting package □ Water heating package
B. D Nonresidential* new construction or alterations :2: $200,000 building permit valuation,
or additions :2: 1,000 square feet □ NIA
Updated 8/15/2019 2
City of Carlsbad Climate Action Plan Consistency Checklist
See CMC 18.21.155 and CALGreen Appendix AS, Division AS.2-Energy Efficiency.
A5.203.1.1 Choose one: D .1 Outdoor lighting D .2 Warehouse dock seal doors
D .3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended) D N/A ________ _
D .4 Daylight design PAFs D .5 Exhaust air heat recovery
AS.203.1.2.1
Choose one as applicable: D .95 Energy budget D .90 Energy budget D N/A
A5.211.1**
D On-site renewable energy D N/A
AS.211.3**
D Green power (if offered by local utility provider, 50% minimum renewable sources) D N/A
A5.212.1
D Elevators and escalators D N/A
A5.213.1
D Steel framing D N/A
• lndudes hotels/motels and high-rise residential buildings
•• For alterations~ $1,000,000 BPV and affecting> 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply
with CMC 18.30.130 instead.
2. Photovoltaic Systems
A. 0 Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California
Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic
requirement (28 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(8)
(high-rise residential) or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PV offset option is selected.
Floor Plan ID (use additional CFA #cl.LI. Calculated kWdc*
sheets if necessary)
Total System Size:
kWdc = (CF Ax.572) / 1,000 + (1.15 x #d.u.)
*Formula calculation where CFA = conditional floor area, #du = number of dwellings per plan type
If proposed system size is less than calculated size, please explain.
Exception
D
D
D
D
kWdc
B. D Nonresidential new construction or alterations ~$1,000,000 BPV and affecting ~75% existing floor area, or addition that increases roof
area by ~2,000 square feet Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to
high-rise residential and hotel/motel buildings.
Choose one of the following methods:
D Gross Floor Area (GFA) Method
GFA:
D If< 10,000s.f. Enter: 5 kWdc
Min. System Size:
D If 2! 1 0,000s.f. calculate: 15 kWdc x (GFA/10,000) **
kWdc
**Round building size factor to nearest tenth, and round system size to nearest whole number.
□ Time-Dependent Valuation Method
Updated 8/15/20 19 3
City of Carlsbad Climate Action Plan Consistency Checklist
Annual TDV Energy use:••• ______ x .80= Min. system size: _____ kWdc
***Attach calculation documentation using modeling software approved by the California Energy Commission.
3. Water Heating
A D Residential and hotel/motel new construction
Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section.
D For systems serving individual dwelling units choose one:
D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise
residential only) D Heat pump water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise
residential hotel/motel) or CA Energy Code section 150.1 (c) 14 (low-rise residential)
D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher
D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors
0 Exception:
D For systems serving multiple dwelling units, install a central water-heating system with all of the following:
D Gas or propane water heating system D Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low-
rise residential)
D Solar water heating system that is either: D .20 solar savings fraction
D .15 solar savings fraction, plus drain water heat recovery
□Exception:
B. D Nonresidential new construction
Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section.
O Water heating system derives at least 40% of its energy from one of the following (attach documentation):
D Solar-thermal D Photovoltaics D Recovered energy
□Water heating system is (choose one):
0 Heat pump water heater
0 Electric resistance water heater(s)
□Solar water heating system with .40 solar savings fraction
0 Exception:
Updated 8/15/2019 4
City of Carlsbad Climate Action Plan Consistency Checklist
4. Electric Vehicle Charging
A D Residential New construction and major alterations*
Please refer to Carlsbad Ordinance CMC section 18.21.140 when com letin this section.
One and two-family residential dwelling or townhouse with attached garage:
Done EVSE Ready parking space required D Exception :
□Multi-family residential· D Exception ·
Total Parking Spaces EVSE Spaces
Proposed Capable I Ready I
I I
Calculations: Total EVSE spaces = . 10 x Total parking (rounded up to nearest whole number)
EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest whole number)
EVSE other-Total EVSE spaces -EVSE Installed
(EVSE other may be "Capable," "Ready" or "Installed.')
Installed I Total
I
*Major alterations are: (1) for one and two-family dwellings and townhouses wth attached garages, alterations have a building permit valuation ~ $60,000
or indude an electrical service panel upgrade; (2) for multifamily dwellings (three units or more wlhout attached garages), alterations have a building permit
valuation ~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing
systems are proposed.
B D Nonresidential new construction (includes hotels/motels) 0 Exception ·
Total Parking Spaces EVSE Spaces
Proposed Capable I Ready I Installed I Total
10 2 I 5 I 1 I 8
Calculation: Refer to the table below:
Total Number of Parkinq Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces -0-9 1 1
10-25 2 1
26-50 4 2
□ 51-75 6 3
□ 76-100 9 5 -101-150 12 6
151-200 17 9
201 and over 10 percent of total 50 percent of Required EV Spaces
Updated 8/15/2019 5
City of Carlsbad Climate Action Plan Consistency Checklist
5. D Transportation Demand Management (TOM): Nonresidential ONLY
An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT.
City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TOM plan. If TOM is applicable to your
permit, staff will contact the applicant to develop a site-specific TOM plan based on the permit details.
Acknowledgment:
Employee ADT Estimation for Various Commercial Uses
Emp ADTfor
first 1,000 s.f.
EmpADT/
1000 s.f.1
Office (all)2 20
Restaurant 11
Retai'3 8
Industrial 4
Manufacturing 4
Warehousin 4
1 Unless otherwise noted, rates estimated from /TE Trip
Generation Manual, 1 ()lhEdition
13
11
4.5
3.5
3
1
2 For all office uses, use SANDAG rate of 20 ADT/1,000 sf to
calculate employee ADT
3 Retail uses include shopping center, variety store, supermarket,
gyms, pharmacy, etc.
Other commercial uses may be subject to special
consideration
Sample calculations:
Office: 20,450 sf
1. 20,450 sf/ 1000 x 20 = 409 Employee ADT
Retail: 9,334 sf
1. First 1,000 sf= 8 ADT
2. 9,334 sf -1,000 sf= 8,334 sf
3. 8,334 sf/ 1,000 x 4.5 + 8 = 46 Em lo ee ADT
I acknowledge that the plans submitted ma e subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should
my permit require a TOM plan and und tand that an roved TOM plan is a condition of permit issuance.
Date: 4/13/2020
Person other than Applicant to be co
Name (Printed): __________________ _ Phone Number: _____ _
Email Address: ___________________ _
Updated 8/15/2019 6