Loading...
HomeMy WebLinkAbout2616 ARGONAUTA ST; ; CBR2020-0801; PermitBuilding Permit Finaled Residential Permit Print Date: 05/07/2021 Job Address: 2616 ARGONAUTA ST, CARLSBAD, CA 92009-6501 Permit Type: BLDG-Residential Work Class: Parcel#: 2154600800 Track#: Valuation: $34,138.34 Lot#: Occupancy Group: #of Dwelling Units: 1 Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check #: Description: CONVERT 734 SF GARAGE TO ADU Applicant: REYHANE BASSAMTABAR 763 2ND ST ENCINITAS, CA 92024-4481 (413) 847-1541 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Property Owner: SARA MOUSAVI 2614 ARGONAUTA ST CARLSBAD, CA 92009-6501 (860) 328-1704 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Second Dwelling Unit Total Fees: $853.44 Total Payments To Date: $853.44 (city of Carlsbad Permit No: CBR2020-0801 Status: Applied: Issued: Fina led Close Out: Inspector: Final Inspection: Balance Due: Closed -Finaled 04/14/2020 09/01/2020 PDrei 05/07/2021 AMOUNT $310.00 $217.00 $41.00 $175.00 $42.00 $62.00 $2.00 $4.44 $0.00 Please take NOTICE that approval of your project includes the "lmposition11 of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov {cicyof Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Check CAA2.02Q-QOOI Est. Value 3':\, l?>'c PC Deposit --------- Date 04/14/2020 ~I.P Job Address ::Ill:= Argonauta St. Carlsbad, CA 92009 Suite: ____ APN: 215-460-08-00 CT/Project#: __________________ Lot #:_72_5 __ _ Fire Sprinklers: OYES 0 NO Air Conditioning: 0 YES ONO Electrical Panel Upgrade: 0 YES 0 NO BRIEF DESCRIPTION OF WORK: The existing garage will be converted to a living space. A kitchen, closet and bathroom will be added. Three parking doors will be demolished, one regular door with sidelights and two windows will be added to that wall. 0 Addition/New: _____ Living SF, ____ Deck SF, ____ Patio SF, ____ Garage SF Is this to create an Accessory Dwelling Unit? 0 YON New Fireplace? 0 YON, if yes how many? __ [Z] Remodel: _7_3_4 ___ SF of affected area Is the area a conversion or change of use ? 0 Y ON 0 Pool/Spa: ____ SF Additional Gas or Electrical Features? _____________ _ □solar: ___ KW, __ Modules, Mounted:O Roof OGround, Tilt: 0 YO N, RMA: 0 YON, Battery:OY ON, Panel Upgrade: Ov ON D Reroof: --------------------------------- □ Plumbing/Mechanical/Electrical Only: _______________________ _ D Other: _________________________________ _ APPLICANT (PRIMARY CONTACT) Name: Reyhane Bassamtabar Address: 763 2nd St. City: Encinitas, Phone: 4138471541 State:_C_A __ .Zip: 92024 Email: reyhane.basam@gmail.com DESIGN PROFESSIONAL Name: __________________ _ Address: _________________ _ City: ________ State: ___ .Zip: ___ _ Phone: _________________ _ Email: __________________ _ Architect State License: ___________ _ PROPERTY OWNER Name: Sara S. Mousavi Address: 2614 Argonauta St. City: Carlsbad Phone: 8603281704 State:_C_A __ ,Zip: 92009 Email: sara.sharifmousavi@gmail.com CQ(IITRACTOR BUSINESS Na~..:,,..,._ ________________ _ Address: _S_·-:.:...--------------- City: '::::::,_ State: Zip: Phone:------"--''""·.._-:::::~---~~~~~~~~~~~~~- Email: ________ _:::....,. ________ _ State license: ______ Bus. Li se: ______ _ (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any stru re, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500)). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov 8-1 Page 1 of 2 Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury QM_ of the following declarations: 01 have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. 0 I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: _____________________ _ Policy No. ______________ Expiration Date: _________ _ 0 Certificate of EKempt/on: I certify that in the performance of the work for which this permit is issued, f shalt not employ any person in any manner so as to be come subject to the workers' compensation laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for In Section 3706 of the labor Code, interest and attorney's fees. CONTRACTOR SIGNATURE: □AGENT DATE: ----------------------------- ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: DI, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). C:3.!, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section ____ --,-___ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. QYES Q NO 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. twill provide some of the work, but I have contracted {hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): ow,n """"""'' ~ o..,., "'"" CONSTRUCTION LENDING ENCY :IF ANY: ' I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: ____________________ _ Lender's Address: ____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes/ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes / No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes / No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. thereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALLUABIUTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CllY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations overS'O' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Buildin~ APPLICANT SIGNATURE: ~ ~ DATE: _______ _ 1635 Faraday Ave Carlsbad, CA 92008 B-1 Ph: 760-602-2~ax: 760-602-8558 t/ Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 Permit Type: BLDG-Residential Work Class: Second Dwelling Unit Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date BLDG-Electrical Final Friday, May 7, 2021 Application Date: 04/14/2020 Owner: SARA MOUSAVI Issue Date: 09/01/2020 Expiration Date: 07/19/2021 Subdivision: LA COSTA MEADOWS #4 Address: 2616 ARGONAUTA ST IVR Number: 25899 CARLSBAD, CA 92009-6501 Inspection No. Inspection Status Primary Inspector Reinspection Inspection May 7, 2021: (Virtual inspection). No final garage conversion To habitable living space/Building deficiencies. 1. Heating unit/system required to be installed-approved. 2. Electrical, plumbing, and mechanical corrections addressed and scope of garage conversion to habitable living space work completed and approved. 3. Exterior (T/R, W/R), exterior bubble cover receptacles installed securely at two outside locations-approved. 4. Drywall openings around two receptacle locations, silicone caulking sealed all small openings at backside of new electrical receptacles. 5. Rest of garage conversion/remodel to habitable condition space, scope of work, including existing driveway retrofit with new•drain system to capture water.sheet flow, from sloped driveway, redirect water away from new habitable living, garage conversion, addition space•inspected and approved. Yes Page 10 of 10 Permit Type: BLDG-Residential Work Class: Second Dwelling Unit Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date BLDG-Structural Final BLDG-Structural Final Friday, May 7, 2021 Application Date: 04/14/2020 Issue Date: 09/01/2020 Expiration Date: 07/19/2021 IVR Number: 25899 Owner: SARA MOUSAVI Subdivision: LA COSTA MEADOWS #4 Address: 2616 ARGONAUTA ST CARLSBAD, CA 92009-6501 Inspection No. Inspection Status Primary Inspector Reinspection Inspection February 16, 2021: Building deficiencies 1. Heating uniUsystem required to be installed-approved. 2. Electrical, plumbing, and mechanical corrections addressed and minimal/minor work to be completed. 3. Exterior (T/R, W/R), exterior bubble cover receptacles not installed securely at two outside locations. 4. Drywall openings around two receptacle locations, need caulking and not allowing openings to backside of new electrical receptacles. 5. Rest of garage conversion/remodel to habitable condition space, scope of work-approved. May 7, 2021: (Virtual inspection). No final garage conversion To habitable living space/Building deficiencies. 1. Heating uniUsystem required to be installed-approved. 2. Electrical, plumbing, and mechanical corrections addressed and scope of garage conversion to habitable living space work completed and approved. 3. Exterior (T/R, W/R), exterior bubble cover receptacles installed securely at two outside locations-approved. 4. Drywall openings around two receptacle locations, silicone caulking sealed all small openings at backside of new electrical receptacles. 5. Rest of garage conversion/remodel to habitable condition space, scope of work, including existing driveway retrofit with new-drain system to capture water-sheet flow, from sloped driveway, redirect water away from new habitable living, garage conversion, addition space-inspected and approved. Yes Yes Page 9 of 10 Permit Type: BLDG-Residential Work Class: Second Dwelling Unit Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item BLDG-Plumbing Final BLDG-Mechanical Final Friday, May 7, 2021 Application Date: 04/14/2020 Owner: SARA MOUSAVI Issue Date: 09/01/2020 Expiration Date: 07/19/2021 IVR Number: 25899 Subdivision: LA COSTA MEADOWS #4 Address: 2616 ARGONAUTA ST CARLSBAD, CA 92009-6501 Inspection No. COMMENTS Inspection Status May 7, 2021: (Virtual inspection). Primary Inspector No final garage conversion To habitable living space/Building deficiencies. 1. Heating unit/system required to be installed-approved. 2. Electrical, plumbing, and mechanical corrections addressed and scope of garage conversion to habitable living space work completed and approved. 3. Exterior (T/R, W/R), exterior bubble cover receptacles installed securely at two outside locations-approved. 4. Drywall openings around two receptacle locations, silicone caulking seated all small openings at backside of new electrical receptacles. 5. Rest of garage conversion/remodel to habitable condition space, scope of work, including existing driveway retrofit with new-drain system to capture water-sheet flow, from sloped driveway, redirect water away from new habitable living, garage conversion, addition space-inspected and approved. May 7, 2021: (Virtual inspection). No final garage conversion To habitable living space/Building deficiencies. 1. Heating uniVsystem required to be installed-approved. 2. Electrical, plumbing, and mechanical corrections addressed and scope of garage conversion to habitable living space work completed and approved. 3. Exterior (T/R, W/R), exterior bubble cover receptacles installed securely at two outside locations-approved. 4. Drywall openings around two receptacle locations, silicone caulking sealed all small openings at backside of new electrical receptacles. 5. Rest of garage conversion/remodel to habitable condition space, scope of work, including existing driveway retrofit with new-drain system to capture water-sheet flow, from sloped driveway, redirect water away from new habitable living, garage conversion, addition space-inspected and approved. Reinspection Inspection Passed Yes Yes Page 8 of 10 Permit Type: BLDG-Residential Work Cl 0 ass: Second Dwelling Unit Status; Scheduled Date 05/0712021 Closed -Finaled Actual Inspection Type Start Date BLDG-Structural Final BLDG-Electrical Final 05/07/2021 BLDG-Final Inspection Friday, May 7, 2021 Application Date: 04/14/2020 Owner: SARA MOUSAVI Issue Date: 09/01/2020 Subdivision: LA COSTA MEADOWS #4 Expiration Date: 07/19/2021 IVR Number: 25899 Address: 2616 ARGONAUTA ST CARLSBAD, CA 92009-6501 Inspection No. Inspection Status Primary Inspector Reinspection Inspection February 16, 2021: Building deficiencies 1. Heating uniVsystem required to be installed-approved. 2. Electrical, plumbing, and mechanical corrections addressed and minimal/minor work to be completed. 3. Exterior (T/R, W/R), exterior bubble cover receptacles not installed securely at two outside locations. 4. Drywall openings around two receptacle locations, need caulking and not allowing openings to backside of new electrical receptacles. 5. Rest of garage conversion/remodel to habitable condition space, scope of work-approved. February 16, 2021: Building deficiencies 1. Heating uniUsystem required to be installed-approved. 2. Electrical, plumbing, and mechanical corrections addressed and minimal/minor work to be completed. 3. Exterior {T/R, W/R), exterior bubble cover receptacles not installed securely at two outside locations. 4. Drywall openings around two receptacle locations, need caulking and not allowing openings to backside of new electrical receptacles. 5. Rest of garage conversion/remodel to habitable condition space, scope of work-approved. 156887-2021 Passed Tony Alvarado Yes Yes Complete Page 7 of 10 ~ M -'M -~"0:9£z,,, -:::-,~ ?€ -, ' -/ti • M % o/ ;;""' ' •. .. 7 {:PERMIT;~tf8eciiliN1tt11JORYlaJi1.,J:1Bao~o.-:-da0:1J:· · · ~ . Permit Type: BLDG-Residential Work Class: Second Dwelling Unit Status: Closed -Finaled Application Date: 04/14/2020 Owner: SARA MOUSAVI Issue Date: 09/01/2020 Subdivision: LA COSTA MEADOWS #4 Expiration Date: 07/19/2021 IVR Number: 25899 Address: 2616 ARGONAUTA ST CARLSBAD, CA 92009-6501 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final Friday, May 7, 2021 COMMENTS February 5, 2021: Building deficiencies 1. Heating units required to be installed. 2. corrections need to be addressed on back of permit card. 3. Electrical, plumbing, and mechanical corrections need to be addressed. February 16, 2021: Building deficiencies 1. Heating uniVsystem required to be installed-approved. 2. Electrical, plumbing, and mechanical corrections addressed and minimal/minor work to be completed. 3. Exterior (T/R, W/R), exterior bubble cover receptacles not installed securely at two outside locations. 4. Drywall openings around two receptacle locations, need caulking and not allowing openings to backside of new electrical receptacles. 5. Rest of garage conversion/remodel to habitable condition space, scope of work-approved. February 16, 2021: Building deficiencies 1. Heating uniUsystem required to be installed-approved. 2. Electrical, plumbing, and mechanical corrections addressed and minimal/minor work to be completed. 3. Exterior (T/R, W/R), exterior bubble cover receptacles not installed securely at two outside locations. 4. Drywall openings around two receptacle locations, need caulking and not allowing openings to backside of new electrical receptacles. 5. Rest of garage conversion/remodel to habitable condition space, scope of work-approved. Passed No Yes Yes Page 6 of 10 • ~ , _='::§;:" ~ __ :sJ'-::::,,4-10'-~ "' Al 7'1¾S,~;~t ' ," , ~ • • 0 : • ·;!PERMIT QISR&e~·-.:itttISlfrliillor (CBR2oio-:QSCX1l~::;,:-~ _, : .. : Permit Type: BLDG-Residential Work Class: Second Dwelling Unit Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item Application Date: 04/14/2020 Owner: SARA MOUSAVI Issue Dato: 09/01/2020 Subdivision: LA COSTA MEADOWS #4 Expiration Date: 07/19/2021 IVR Number: 25899 Inspection No. COMMENTS Inspection Status Address: 2616 ARGONAUTA ST CARLSBAD. CA 92009-6501 Primary Inspector Reinspection Inspection Passed BLDG-Building Deficiency February 5, 2021: No BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Electrical Final 02/1612021 02/1612021 BLDG-Final Inspection Friday, May 7, 2021 Building deficiencies 1. Heating units required to be installed. 2. corrections need to be addressed on back of permit card. 3. Electrical, plumbing, and mechanical corrections need to be addressed. February 5, 2021: Building deficiencies 1. Heating units required to be installed. 2. corrections need to be addressed on back of permit card. 3. Electrical, plumbing, and mechanical corrections need to be addressed. February 5, 2021: Building deficiencies 1. Heating units required to be installed. 2. corrections need to be addressed on back of permit card. 3. Electrical, plumbing, and mechanical corrections need to be addressed. February 5, 2021: Building deficiencies 1. Heating units required to be installed. 2. corrections need to be addressed on back of permit card. 3. Electrical, plumbing, and mechanical corrections need to be addressed. 150609-2021 Partial Pass Tony Alvarado No No No Reinspectlon Incomplete Page 5 of 10 Application Date: 04/14/2020 Owner: SARA MOUSAVI Permit Type: BLDG-Residential Work Class: Second Dwelling Unit Issue Date: 09/01/2020 Subdivision: LA COSTA MEADOWS #4 Status: Scheduled Date 01/19/2021 02/0512021 Closed -Finaled Expiration Date: 07/19/2021 IVR Number: 25899 Address: 2616 ARGONAUTA ST CARLSBAD, CA 92009-6501 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection 01/19/2021 02/0512021 BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers January 6, 2021: 1. Rough framing Inspection, for existing (2) car garage conversion to a new ADU Habitable space/living area, per architectural/structural engineer's revised plan details and specifications -approved. 2. Owner will provide two sets of revised framing detailing, depicting exterior existing garage door wall converted to new ADU entry door wall, with new infilling framing, and new stepped concrete curb-approved. 3. New plumbing waste and vent lines and new electrical lines, scope of work-approved. 4. New mechanical venting for new a DU restroom and kitchenette-approved. January 6, 2021: 1. Rough framing Inspection, for existing (2) car garage conversion to a new ADU Habitable space/living area, per architectural/structural engineer's revised plan details and specifications -approved. 2. Owner will provide two sets of revised framing detailing, depicting exterior existing garage door wall converted to new ADU entry door wall, with new infilling framing, and new stepped concrete curb-approved. 3. New plumbing waste and vent lines and new electrical lines, scope of work-approved. 4. New mechanical venting for new a DU restroom and kitchenette-approved. BLDG-17 Interior 148575-2021 Passed Paul Burnette Lath/Drywall Checklist Item COMMENTS BLDG-Building Deficiency NOTES Created By TEXT Paul Burnette Video inspection BLDG-Final Inspection 149838-2021 failed Tony Alvarado Yes Yes Complete Passed Yes Created Date 01/19/2021 Reinspection Incomplete Friday, May 7, 2021 Page 4 of 10 ~' fi ::--", -:!:"½,:Y,iff:P~ 0 r;q •~ ",~:;f: , ~ T': 1' X cd ~ · \;pERMIT INSREC!'f'Il>Jll§tll$"'C~R'f~Q,[ (CBR~Q20~Qao11.,._ . - Permit Type: BLDG-Residential Work Class: Second Dwelling Unit Application Date: 04/14/2020 Owner: SARA MOUSAVI Status: Closed -Finaled Issue Date: 09/01/2020 Subdivision: LA COSTA MEADOWS #4 Expiration Date: 07/19/2021 IVR Number: 25899 Address: 2616 ARGONAUTA ST CARLSBAD, CA 92009-6501 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Friday, May 7, 2021 Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout COMMENTS Not ready, exterior flashing and weep screed not installed properly. Exterior sheathing not nailed/screwed properly. Stud wall framing not 16"o.c. Per plan, no plumbing, electrical, or mechanical completed. Call for reinspection January 6, 2021: 1. Rough framing Inspection, for existing (2) car garage conversion to a new ADU Habitable space/living area, per architectural/structural engineer's revised plan details and specifications -approved. 2. Owner will provide two sets of revised framing detailing, depicting exterior existing garage door wall converted to new ADU entry door wall, with new infilling framing, and new stepped concrete curb-approved. 3. New plumbing waste and vent lines and new electrical lines, scope of work-approved. 4. New mechanical venting for new a DU restroom and kitchenette-approved. 5. Sound metal resilient channel (hat channel), installed anchored/fastened correctly-approved. January 6, 2021: 1. Rough framing Inspection, for existing (2) car garage conversion to a new ADU Habitable space/living area, per architectural/structural engineer's revised plan details and specifications -approved. 2. Owner will provide two sets of revised framing detailing, depicting exterior existing garage door wall converted to new ADU entry door wall, with new infilling framing, and new stepped concrete curb-approved. 3. New plumbing waste and vent lines and new electrical lines, scope of work-approved. 4. New mechanical venting for new a DU restroom and kitchenette-approved. Passed No Yes Yes Page 3 of 10 Application Date: 04/14/2020 Owner: SARA MOUSAVI Permit Type: BLDG-Residential Work Class: Second Dwelling Unit Issue Date: 09/01/2020 Subdivision: LA COSTA MEADOWS #4 Status: Scheduled Date 0110612021 Closed -Finaled Expiration Date: 07/19/2021 IVR Number: 25899 Address: 2616 ARGONAUTA ST CARLSBAD, CA 92009-6501 Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Top out BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers Status COMMENTS Not ready, exterior flashing and weep screed not installed properly. Exterior sheathing not nailed/screwed properly. Stud wall framing not 16"o.c. Per plan, no plumbing, electrical, or mechanical completed. Call for reinspection 01106/2021 BLDG-84 Rough Combo(14,24,34,44) 147618-2021 Passed Tony Alvarado Passed No No No No No Complete Friday, May 7, 2021 Page 2 of 10 Building Permit Inspection History Finaled (city of Carlsbad Application Date: 04/14/2020 Owner: SARA MOUSA VI Permit Type: BLDG-Residential Work Class: Second Dwelling Unit Issue Date: 09/01/2020 Subdivision: LA COSTA MEADOWS #4 Status: Closed -Finaled Expiration Date: 07/19/2021 Address: 2616 ARGONAUTA ST CARLSBAD, CA 92009-6501 IVR Number: 25899 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Date Start Date Status 11/13/2020 1111312020 BLDG-14 143726-2020 Failed Peter Dreibelbis Reinspectlon Frame/Steel/Boltlng/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency No one home at 12:10 No 11116/2020 11/1612020 BLDG-14 143828-2020 Failed Tony Alvarado Reinspection Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency No one home at 12:10 No November 16, 2020: no plans on site and framing inspection failed. Spoke to owner about pressure-treated sill plates required at exterior walls and plans required on site. 11/18/2020 1111812020 BLDG-14 144068-2020 Failed Tony Alvarado Reinspectlon Frame/Steel/BoltlnglWe lding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency No one home at 12:10 No November 16, 2020: no plans on site and framing inspection failed. Spoke to owner about pressure-treated sill plates required at exterior walls and plans required on site. BLDG-Building Deficiency November 18, 2020: (inspection failed). No 1. Spoke to owner about pressure-treated sill plates required at exterior walls and plans do not add_ress pressure-treated plates at front elevation. 3. finish exterior grade is same height as interior finish floor living/dwelling finish height level. No barrier or 8" concrete stemwall, or flashing between exterior finish level and interior dwelling/ADU finish floor level. 1211712020 12/17/2020 BLDG-84 Rough 146500-2020 Failed Chris Renfro Reinspectlon Combo(14,24,34,44) Friday, May 7, 2021 Inspection Incomplete Incomplete Incomplete Incomplete Page 1 of 10 ✓• EsG1I A SAFf.budt Colllpany DATE: 5/20/2020 JURISDICTION: Carlsbad PLAN CHECK#.: cbR2020-0801 PROJECT ADDRESS: 2616 Argonaula St. PROJECT NAME: Remodel for an ADU SET II ~PPLICANT / URIS. ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted"ipo /2-0(b$W'6 Mail Telephone Fax In Person 0 REMARKS: By: Richard Moreno EsGil 5/12/2020 Telephone#: Email: Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 ✓• EsG1I A SAFEbui!r Company DATE: 4/24/2020 JURISDICTION: Carlsbad PLAN CHECK#.: cbR2020-0801 PROJECT ADDRESS: 2616 Argonaula St. PROJECT NAME: Remodel for an ADU SETI D APPLICANT D JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [8J The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [8J The applicant's copy of the check list has been sent to: Reyhane Bassamtabar D EsGil staff did not advise the applicant that the plan check has been completed. [8:l EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Reyhane Bassamtabar Telephone#: 413-847-1541 Date contacted: (by: ) Email: reyhane.basam@gmail.com Mail Telephone Fax In Person 0 REMARKS: By: Richard Moreno EsGil 4/16/2020 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad cbR2020-0801 4/24/2020 a) All fans installed to meet all of the preceding ventilation requirements must be specified at a noise rating of a maximum 1 "Sane" (continuous use) or 3 "Sane" (intermittent). MISCELLANEOUS 26. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 27. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 28. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Richard Moreno at EsGil. Thank you. Carlsbad cbR2020-0801 4/24/2020 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: cbR2020-0801 JURISDICTION: Carlsbad PROJECT ADDRESS: 2616 Argonaula St. FLOOR AREA: Remodel: 734 sq-ft REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 4/24/2020 FOREWORD (PLEASE READ): STORIES: 2 HEIGHT: no change DATE PLANS RECEIVED BY ESGIL CORPORATION: 4/16/2020 PLAN REVIEWER: Richard Moreno This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2019 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2018 IRC, 2018 IBC, 2018 UPC, 2018 UMC and 2017 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2018 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad cbR2020-0801 4/24/2020 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Richard Moreno BUILDING ADDRESS: 2616 Argonaula St. BUILDING OCCUPANCY: PLAN CHECK#.: cbR2020-0801 DATE: 4/24/2020 BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier remodel 734 citv est Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance .. 1997 UBC Buildin Permit Fee g 'l• . .. J 1997 UBC Plan Check Fee Type of Review: D Repetitive Fee ~ Repeats __-2.l D Complete Review D Other D Hourly EsGII Fee Reg. VALUE ($) Mod. 34,138 34,138 l D Structural Only 1--------<1 Hr. @ * $201.821 comments: ll'.l{li!.ciciltit>r;ifgtneabqvefEie,arfadditicfos.lfeeof$ .··tsdUel .·····oour@ $. W<Jhri[{fQr'th~~~i~r~ijn>Pe~l~W. . . . . . . . . Sheet of Carlsbad cbR2020-0801 4/24/2020 PLANS 1. The following note should be given with each correction list Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. 4. Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: a) Glazing in doors. b) Glazing adjacent to a door where the bottom exposed edge of the glazing is less than 60" above the walking surface. and it meets either of the following conditions: i) Where the glazing is within 24" of either side of the door in the plane of the door in a closed position. 5. There shall be a landing or floor on each side of each exterior door. The width of each landing shall be not less than the door served. Every landing shall have a dimension of not less than 36 inches measured in the direction of travel. The slope at exterior landings shall not exceed ¼ unit vertical in 12 units horizontal (2 percent). Landing shall be not more than 7-3/4 inches below the top of the threshold. R311.3. Carlsbad cbR2020-0801 4/24/2020 6. Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor-- ceilings and roof-ceilings shall be protected as required in CRC Section R302.4." 7. Walls and floors separating units in a duplex shall have a sound transmission class (STC) of not less than 50. Additionally, floors must have an impact insulation class (IIC) rating of not less than 50. CBC Section 1207. Show the location of and provide details of the listed wall and floor/ceiling assemblies and indicate the listing agency and listing number for the tested ratings. 8. Floor assemblies separating units in a duplex shall be of one-hour fire resistive construction (½-hour if the building has an automatic sprinkler system). Provide details of the assemblies. Section R302.3. Such assemblies shall extend to and be tight to the exterior wall, where applicable. 9. Unless Garage is for the sole usage of ADU tenant, walls between garage and ADU must be fire and sound rated. 10. The supporting construction of fire-rated floor assemblies shall have an equal or greater fire-rating. Section R302.3.1. PLUMBING 11. Show water heater size (1 st hour rating), type, and location on plans. Note: For both new dwellings and additions the Energy Standards (150.0(n)) requires a gas input rating of 200,000 Btu for both tank and instantaneous gas water heaters. (Also) Provide a gas piping design for the gas system. 12. ADU must have access to either an existing accessible water heating appliance, or its own independent appliance. 13. Show the T and P relief valve at the water heater and the discharge pipe size and routing to the exterior. CPC Section 608.3. ELECTRICAL 14. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If the service is over 200 amperes, submit a single line diagram, panel schedules, and provide service load calculations. 15. Note on the plans that receptacle outlet locations will comply with CEC Article 210.52. 16. A receptacle outlet must be installed in every kitchen, family room, dining room, living room, sunroom, parlor, library, den, bedroom, recreation room, and similar room or area so that no point along the wall space is more than 6 feet, measured horizontally along the floor line, from a receptacle outlet CEC 210.52(A) Carlsbad cbR2020-0801 4/24/2020 17. A balcony, deck, or porch that is accessible from the interior of the dwelling will require a minimum of one receptacle outlet. CEC 210.52(E) (3). This receptacle must be GFCI protected. 18. Show on the plans that countertop receptacle outlets comply with CEC Article 210.52(C): In kitchens a receptacle outlet shall be installed at each counter space 12 inches or wider; Receptacles shall be installed so that no point along the wall line is more than 24 inches; Island and peninsular countertops 12 inches by 24" long (or greater) shall have at least one receptacle. (Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces). 19. Per CEC Article 210.11 (C)1, note on the plans that there will be a minimum of 2 small appliance branch circuits within the locations specified in Article 210.52(8), i.e., kitchen and dining areas. 20. Per CEC Article 210.11 (C)3, note on the plans that bathroom circuiting shall be either: a) A 20-ampere circuit dedicated to each bathroom, or b) At least one 20 ampere circuit supplying only bathroom receptacle outlets. 21. An ADU may have a separate utility service installed, or sub fed via existing service with adequate capacity. ADU's require electrical load calculations per CEC 220.83 to justify existing electrical service size is adequate. ENERGY CONSERVATION Residential ventilation requirements: ES 150.0(o)/ASHRAE 62.2 22. Kitchens require exhaust fans with a minimum 100 cfm ducted to the exterior. Detail compliance by including a complying exhaust fan or a ducted range hood to the exterior. 23. Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the exterior. A bathroom is defined "as a room with a bathtub, shower, or spa or some similar source of moisture". 24. Residential bathroom exhaust fans shall be energy star rated and shall be control by a humidistat capable of an adjustment between 50 and 80% humidity. CalGreen 4.506.1. Exception: Control by a humidistat is not required if the bathroom exhaust fan is also the dwelling whole house ventilation. 25. Mechanical whole house ventilation must be provided. Identify the fan providing the whole house ventilation (complete with CFM and Sane rating) on the floorplans. For additions 1,000 square feet or less, whole house ventilation is not required. For additions over 1,000 square feet, the whole house ventilation CFM shall be based upon the entire (existing and addition) square footage, not just the addition. CERTIFICATION OF SCHOOL FEES PAID c:ornpleted bY the City, the eppllcant, atld the appropriate school districts and returned to the Clt 11'1'$ form must Jt g permit. The City will not issue any bufldlng permit Without a completed $Choo! fee form. Y Prior to 1ss1.11n9 a r,ull n Project# & Name: Permit#: project Address: CBR2020-080l 2616 ARGONAUT A ST Assessor's Parcel#; :.2:.:15::.:14~6.::::00:c8;.;:0;.::;.0 ____ ....... ......, _________ _ Project Applicant; .:::;SA:;.;;R:.;:A.;..M;.;,;_O..;:;U.;;.SA;..;.V.;,.;1 ____________ _ (Owner Name) Residential Square Feet: New/Additions:·--'----------------- Second Dwelling Unit 734 (Convert garage to ADU) Commercial Square Feet: New/Additions: _________________ _ City Certification; City of Carlsbad Building Division Date: 07/07/2020 Certification of ApplicanVOWners. The person executing this declaration ("Owner") oertifi8/J under penalty of perjury that (1) the Information provided above is correct and true to the best of the Owner's knowledge, and that the OWner will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number of dWelling units or square footage after the b1.11fdin9 pennit is issued or if the initial determination of units or square footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described project(s), or that the person executing this declaration is authorized to sign on behalf of the Owner. m Cart1bad UrlJfled School.,..... 6225 El Camino Real Cartabad CA 92009 Phone: (760) 331-!S<IOO [ii Enclnltfl Union IOMol ..._ 101 SouthRanc::hoSamclFe,W Encinitaa, CA 92024 Phone: (700) 944-4300 ,rt 'tel •• San Diegulto Union HJt. ...... 684 Requeza Or. Enclnitat, CA 92024 Phone: (760) 753-6491 EJCt 551-4 (By Appl Only) • s.n Marco. Unified lcb. 255 Pico Ave Ste. 100 San Marcos, CA 92089 Ph<>ne: (760) 290-2849 Contact: Katherine Marcella (By Appt.only) • Vista Unified School Mdrtcl 1234 Arcadia Drive Vista CA 92083 PhOne: {760) 726-2170 ~ SCHOOL DISTRICT SCHOOL FEE CERTIFICATION (To be completed by the school district(•)) THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIRl:t«N FOR THE PROJECT HAVE BEEN OR WILL BE SATISFI&D. • • . • • • . • • • I Title: Name of School District: Ccityof Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool All If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. ..i1 Details on CAP ordinance requirements are available on the city's website. All A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. Project Name/Building Permit No.: Mousavi ADU BPNo.:Cf;)R2.020-Qc()I ------------------- Property Address/APN: 215-460-08-00 Applicant Name/Co.: Reyhane Bassamtabar Applicant Address: 763 2nd St. Encinitas, CA 92024 Contact Phone: 41384 71541 Contact Email: reyhane.basam@gmail.com Contact information of person completing this checklist (if different than above): Name: Company name/address: Reyhane Bassamtabar Contact Phone: 763 2nd St, Contact Email: 4138471541 reyhane.basam@gmail.com Applicant Signature:--------/ ________ Date: 4/13/2020 Encin~::A 92024 f.f:? B-50 Page 1 of 6 Revised 08/19 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet: $ ______ _ Con1t111ctlon Type 0 Residential □ New construction □ Additions and alterations: □ BPV < $60,000 □ BPV ~ $60,000 □ Electrical service panel upgrade only □ BPV ~ $200,000 D Nonresidential ' □ New construction □ Alterations: □ BPV ~ $200,000 or additions~ 1,000 square feet □ BPV ~ $1,000,000 □ ~ 2,000 sq. ft. new roof addition Checkllat Item Complete Sectlon(a) Note&: A high-rise residential building is 4 or more stories, including a Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use 2A, 3A, 18, 2B, 4A 38,4A NIA NIA All residential additions and alterations 1A, 4A 4A 1-2 family dwellings and townhouses with attached garages only *Multi-family dwellings only where interior finishes are removed 1A, 4A* 18, 4A* and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed 18, 28, 38, 48 and 5 18,5 18, 28, 5 Building alterations of~ 75% existing gross floor area 28,5 18 also applies if BPV ~ $200,000 Check the appropriate boxes, e)(plain all not applicable and exception Items, and provide supporting calw ations and documentatton as necessary. 1. Energy Efficiency Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for more information when completing this section. A D Residential addition or alteration :2: $60,000 building permit valuation. See CMC section 18.30.190. Year Built Single-family Requirements □ Before 1978 Select one: □ Duct sealing □ Attic insulation □Cool roof □ 1978 and later Select one: □ Lighting package □ Water heating Package 0 Between 1978 and 1991 □ 1992 and later □ NIA. _________ _ □ Exception: Home energy score i! 7 (attach certification) Multi-family Requirements □ Attic insulation Select one: □ Duct sealino □ Attic insulation □Cool roof Select one: □ Lighting package □ Water heating package B. D Nonresidential* new construction or alterations :2: $200,000 building permit valuation, or additions :2: 1,000 square feet □ NIA Updated 8/15/2019 2 City of Carlsbad Climate Action Plan Consistency Checklist See CMC 18.21.155 and CALGreen Appendix AS, Division AS.2-Energy Efficiency. A5.203.1.1 Choose one: D .1 Outdoor lighting D .2 Warehouse dock seal doors D .3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended) D N/A ________ _ D .4 Daylight design PAFs D .5 Exhaust air heat recovery AS.203.1.2.1 Choose one as applicable: D .95 Energy budget D .90 Energy budget D N/A A5.211.1** D On-site renewable energy D N/A AS.211.3** D Green power (if offered by local utility provider, 50% minimum renewable sources) D N/A A5.212.1 D Elevators and escalators D N/A A5.213.1 D Steel framing D N/A • lndudes hotels/motels and high-rise residential buildings •• For alterations~ $1,000,000 BPV and affecting> 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with CMC 18.30.130 instead. 2. Photovoltaic Systems A. 0 Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (28 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(8) (high-rise residential) or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #cl.LI. Calculated kWdc* sheets if necessary) Total System Size: kWdc = (CF Ax.572) / 1,000 + (1.15 x #d.u.) *Formula calculation where CFA = conditional floor area, #du = number of dwellings per plan type If proposed system size is less than calculated size, please explain. Exception D D D D kWdc B. D Nonresidential new construction or alterations ~$1,000,000 BPV and affecting ~75% existing floor area, or addition that increases roof area by ~2,000 square feet Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: D Gross Floor Area (GFA) Method GFA: D If< 10,000s.f. Enter: 5 kWdc Min. System Size: D If 2! 1 0,000s.f. calculate: 15 kWdc x (GFA/10,000) ** kWdc **Round building size factor to nearest tenth, and round system size to nearest whole number. □ Time-Dependent Valuation Method Updated 8/15/20 19 3 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:••• ______ x .80= Min. system size: _____ kWdc ***Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A D Residential and hotel/motel new construction Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. D For systems serving individual dwelling units choose one: D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) D Heat pump water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1 (c) 14 (low-rise residential) D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors 0 Exception: D For systems serving multiple dwelling units, install a central water-heating system with all of the following: D Gas or propane water heating system D Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low- rise residential) D Solar water heating system that is either: D .20 solar savings fraction D .15 solar savings fraction, plus drain water heat recovery □Exception: B. D Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. O Water heating system derives at least 40% of its energy from one of the following (attach documentation): D Solar-thermal D Photovoltaics D Recovered energy □Water heating system is (choose one): 0 Heat pump water heater 0 Electric resistance water heater(s) □Solar water heating system with .40 solar savings fraction 0 Exception: Updated 8/15/2019 4 City of Carlsbad Climate Action Plan Consistency Checklist 4. Electric Vehicle Charging A D Residential New construction and major alterations* Please refer to Carlsbad Ordinance CMC section 18.21.140 when com letin this section. One and two-family residential dwelling or townhouse with attached garage: Done EVSE Ready parking space required D Exception : □Multi-family residential· D Exception · Total Parking Spaces EVSE Spaces Proposed Capable I Ready I I I Calculations: Total EVSE spaces = . 10 x Total parking (rounded up to nearest whole number) EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other-Total EVSE spaces -EVSE Installed (EVSE other may be "Capable," "Ready" or "Installed.') Installed I Total I *Major alterations are: (1) for one and two-family dwellings and townhouses wth attached garages, alterations have a building permit valuation ~ $60,000 or indude an electrical service panel upgrade; (2) for multifamily dwellings (three units or more wlhout attached garages), alterations have a building permit valuation ~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. B D Nonresidential new construction (includes hotels/motels) 0 Exception · Total Parking Spaces EVSE Spaces Proposed Capable I Ready I Installed I Total 10 2 I 5 I 1 I 8 Calculation: Refer to the table below: Total Number of Parkinq Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces -0-9 1 1 10-25 2 1 26-50 4 2 □ 51-75 6 3 □ 76-100 9 5 -101-150 12 6 151-200 17 9 201 and over 10 percent of total 50 percent of Required EV Spaces Updated 8/15/2019 5 City of Carlsbad Climate Action Plan Consistency Checklist 5. D Transportation Demand Management (TOM): Nonresidential ONLY An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TOM plan. If TOM is applicable to your permit, staff will contact the applicant to develop a site-specific TOM plan based on the permit details. Acknowledgment: Employee ADT Estimation for Various Commercial Uses Emp ADTfor first 1,000 s.f. EmpADT/ 1000 s.f.1 Office (all)2 20 Restaurant 11 Retai'3 8 Industrial 4 Manufacturing 4 Warehousin 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 1 ()lhEdition 13 11 4.5 3.5 3 1 2 For all office uses, use SANDAG rate of 20 ADT/1,000 sf to calculate employee ADT 3 Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. 8,334 sf/ 1,000 x 4.5 + 8 = 46 Em lo ee ADT I acknowledge that the plans submitted ma e subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a TOM plan and und tand that an roved TOM plan is a condition of permit issuance. Date: 4/13/2020 Person other than Applicant to be co Name (Printed): __________________ _ Phone Number: _____ _ Email Address: ___________________ _ Updated 8/15/2019 6