HomeMy WebLinkAbout2717 WILSON ST; ; CBR2019-2546; PermitBuilding Permit Finaled Residential Permit Print Date: 04/23/2021 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: 2717 WILSON ST, CARLSBAD, CA 92008-1530 BLDG-Residential Work Class: 1561302100 Track#: $113,680.69 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Alteration (city of Carlsbad Permit No: CBR2019-2546 Status: Applied: Issued: Finaled Close Out: Inspector: Final Inspection: Closed -Fina led 09/13/2019 04/23/2020 TAlva 04/23/2021 Description: VEIGA: 1,925 SF REMODEL (RECONFIGURE EXISTING LIVING SPACE)// REMOVE FLAT ROOF AND REPLACE W/ PITCHED ROC Applicant: CARLOS ARCHITECTS INC 3327 ADAMS ST CARLSBAD, CA 92008-2502 (760) 579-3996 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Property Owner: PAHL ARCHIE W JR FAMILY 2717 WILSON ST CARLSBAD, CA 92008 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL REFUND 561473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $3,896.53 Total Payments To Date: $3,896.53 Balance Due: AMOUNT $675.70 $2,861.05 $66.00 $92.00 $182.00 $0.00 $5.00 $14.78 $0.00 Please take NOTICE that approval of your project includes the 11 lmposition" of fees1 dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction. '1 You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov {cicyof Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 PC Deposit --------- Date _'9~-~J·3_,_-_._{q __ JobAddress___;'t-:c......::7c....::l_....,...;...__VJ__:_\L.:=--9<-0_~-'--.. ..:.......:.T' ___ suite: ___ APN: (!'(p -,_o · t.l -oo CT/Project#:, _________________ Lot#:. ___ _ Fire Sprinklers: yes/€:) Air Conditioning: ~ no Electrical Panel Upgrade:@no BRIEF DESCRIPTION OF WORK: I I '\2S" ~ Y1-e'M°'1~ "fl) 6)(.1-;,,"t ~G-'Z.' □ Addition/New: _____ Living SF, ____ Deck SF, ____ Patio SF, ____ Garage SF Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __ WRemodel: \ ,c.:r 2. r SF of affected area Is the area a conversion or change of use? YesE) □ Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _ □ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground , Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes/ No D Reroof: _____________________________________ _ D Plumbing/Mechanical/Electrical Only: ________________________ _ D Other:------------------------------------ DESIGN PROFESSIONAL Name: '-5/Jc ~ ('fU.O'!Nf Address: ________________ _ City: _______ State: ___ .Zip: ___ _ Phone: _________________ _ Email:----------,=-~=,..,...,....,.,..._ ___ _ Architect State License: _,C"""_.,,,e:..,.ffle..=._.._ ... 'f-~---- CONTRACTOR BUSINESS Name: ±~Q Address: __________________ _ City: ________ State: ___ .Zip: ______ _ Phone: ___________________ _ Email: ___________________ _ State License: ______ Bus. License: ______ _ {Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.S by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Page 1 of 2 Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: □ I have and wilt maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. □ I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: ______________________ _ Policy No. ______________ Expiration Date: _________ _ 0 Certificate of Exemption: t certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage ls unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONTRACTOR SIGNATURE: □AGENT DATE: ---------------------------------- ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's license Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 l, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's license Law). 0 I am exempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 Yes O No 2. r (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted {hired) the following persons to provide the work indicated {include name/ address/ phone/ type of work): OWNER SIGNATURE: ___________________ □AGENT DATE: _____ _ CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: ______________________ Lender's Address: _____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes O No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes O No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I Al50 AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARl5BADAGAINST All LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CllY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over S'O' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Co ire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of sue r the building o ork authorized by such permit is suspended or abandoned at anytime after the work is commenced for a period of 180 days (Section 1 . Uniform Building Cod::·[::;.. ___ _ APPLICANT SIGNATURE: 1635 Faraday Ave Carlsbad, CA 92008 8-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of2 DATE: _1 ___ ~.L..1-'-~-.. __,__I_J't.__ Email: Building@carlsbadca.gov Rev. 06/18 Permit Type: BLDG-Residential Work Class: Alteration Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Friday, April 23, 2021 Application Date: 09/13/2019 Owner: TRUST PAHL ARCHIE W JR FAMILY Issue Date: 04/23/2020 Subdivision: WILSONIA TRACT Expiration Date: 09/13/2021 IVR Number: 21744 Addrnss: 2717 WILSON ST CARLSBAD, CA 92008-1530 Inspection No. COMMENTS April 23, 2021: Inspection Status Primary Inspector 1. No NSFD Final/building deficiencies. 2. Final structural, electrical, plumbing, and mechanical work, per structural and architectural plans and design specifications-approved. 3. Verified final third-party special for/deputy inspector reports-approved. 4. Waste management Final receipts, documentation Verified and filed in city records-Approved. April 23, 2021: 1. No NSFD Final/building deficiencies. 2. Final structural, electrical, plumbing, and mechanical work, per structural and architectura I plans and design specifications-approved. 3. Verified final third-party special for/deputy inspector reports-approved. 4. Waste management Final receipts, documentation Verified and filed in city records-Approved. April 23, 2021: 1. No NSFD Final/buildfng deficiencies. 2. Final structural, electrical, plumbing, and mechanical work, per structural and architectural plans and design specifications-approved. 3. Verified final third-party special for/deputy inspector reports-approved. 4. Waste management Final receipts, documentation Verified and filed in city records-Approved. April 23, 2021: 1. No NSFD Final/building deficiencies. 2. Final structural, electrical, plumbing, and mechanical work, per structural and architectural plans and design specifications-approved. 3. Verified final third-party special for/deputy inspector reports-approved. 4. Waste management Final receipts, documentation Verified and filed in city records-Approved. Reinspection Inspection Passed Yes Yes Yes Yes Page 18 of 18 Permit Type: Work Class: Status: Scheduled Date BLDG-Residential Alteration Closed -Finaled Actual Inspection Type Start Date BLDG-Structural Final BLDG-Electrical Final Friday, April 23, 2021 Application Date: 09/13/2019 Owrn?r: TRUST PAHL ARCHIE W JR FAMILY Issue Date: 04/23/2020 Subdivision: WILSONIA TRACT Expiration Date: 09/13/2021 Address: 2717 WILSON ST IVR Number: 21744 CARLSBAD, CA 92008-1530 Inspection No. Inspection Status Primary Inspector Reinspection Inspection April 16, 2021 1. Building-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural scope of work per structural plans and detail specifications -not ready. 3. Inform Enrique, contractor representative, waste management documentation and mandatory energy forms signatures required, and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. 4. Final third-party special/deputy inspector reports. and any structural observation reports, or surveyor or civil engineering final reports required at final inspection. April 16, 2021: 1. Building-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural scope of work per structural plans and detail specifications -not ready. 3. Inform Enrique, contractor representative, waste management documentation and mandatory energy forms signatures required, and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. No No Page 17 of 18 Permit Type: BLDG-Residential Application Date: 09/13/2019 Owner: TRUST PAHL ARCHIE W JR FAMILY Work Class: Alteration Issue Date: 04/23/2020 Subdi;vision: WILSONIA TRACT Status; Closed -Finaled Expiration Date: 09/13/2021 Addrnss: 2717 WILSON ST IVR Number: 21744 CARLSBAD, CA 92008-1530 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final Friday, April 23, 2021 Status COMMENTS April 16, 2021: 1. Buildirg-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural scope of work per structural plans and detail specifications -not ready. 3. Inform Enrique, contractor representative, waste management documentation and mandatory energy forms signatures required, and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. 4. Final third-party special/deputy inspector reports, and any structural observation reports, or surveyor or civil engineering final reports required at final inspection. April 16, 2021: 1. Building-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural scope of work per structural plans and detail specifications -not ready. 3. Inform Enrique, contractor representative, waste management documentation and mandatory energy forms signatures required, and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. April 16, 2021: 1. Building-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural scope of work per structural plans and detail specifications -not ready. 3. Inform Enrique, contractor representative, waste management documentation and mandatory energy forms signatures required, and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. Passed No No No Pago 16 of 18 Permit Type: BLDG-Residential Work Class: Alteration Status: Scheduled Date 04/23/2021 Closed -Finaled Actual Inspection Type Start Date BLDG-Structural Final BLDG-Electrical Final 04/23/2021 BLDG-Final Inspection Friday, April 23, 2021 Application Date: 09/13/2019 Owner: TRUST PAHL ARCHIE W JR FAMILY Issue Date: 04/23/2020 Expiration Date: 09/13/2021 IVR Number: 21744 Subdivision: WILSONIA TRACT Addrnss: 2717 WILSON ST CARLSBAD, CA 92008-1530 Inspection No. April 16, 2021: Inspection Status Primary Inspector 1. Building-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural scope of work per structural plans and detail specifications -not ready. 3. Inform Enrique, contractor representative, waste management documentation and mandatory energy forms signatures required, and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. 4. Final third-party special/deputy inspector reports, and any structural observation reports, or surveyor or civil engineering final reports required at final inspection. April 16, 2021 1. Building-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural s~ope of work per structural plans and detail specifications -not ready. 3. Inform Enrique, contractor representative, waste management documentation and mandatory energy forms signatures required, and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. 155711-2021 Cancelled Tim Kersch Reinspection Inspection No No Relnspection Incomplete Page 15 of 18 Permit Type: BLDG-Residential Work Class: Alteration Status: Closed -Finaled Application Date: 09/13/2019 Own.,,: TRUST PAHL ARCHIE W JR FAMILY Issue Date: 04/23/2020 Expiration Date: 09/13/2021 IVR Number: 21744 Subdivision: WILSONIA TRACT Address: 2717 WILSON ST CARLSBAD, CA 92008-1530 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspectlon Inspection Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final Friday, April 23, 2021 COMMENTS April 16, 2021 1. Building-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural scope of work per structural plans and detail specifications -not ready. 3. Inform Enrique, contractor representative, waste management documentation and mandatory energy forms signatures required, and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. 4. Final third-party special/deputy inspector reports, and any structural observation reports, or surveyor or civil engineering final reports required at final inspection. April 16, 2021: 1. Building-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural scope of work per structural plans and detail specifications -not ready. 3. Inform Enrique, contractor representative, waste management documentation and mandatory energy forms signatures required, and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. April 16, 2021: 1. Building-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural scope of work per structural plans and detail specifications -not ready. 3. Inform Enrique. contractor representative, waste management documentation and mandatory energy forms signatures required, and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. Passed No No No Page 14 of 18 Permit Type: BLDG-Residential Work Class: Alteration Status: Scheduled Date 04/21/2021 Closed -Finaled Actual Inspection Type Start Date BLDG-Structural Final BLDG-Electrical Final BLDG-Final Inspection Friday, April 23, 2021 Application Date: 09/1312019 Owm,r: TRUST PAHL ARCHIE W JR FAMILY Issue Date: 04/2312020 Subdivision: WILSONIA TRACT Expiration Date: 0911312021 IVR Number: 21744 Address: 2717 WILSON ST CARLSBAD, CA 92008-1530 Inspection No. April 16, 2021: Inspection Status Primary Inspector 1. Building-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural scope of work per structural plans and detail specifications -not ready. 3. Inform Enrique, contractor representative, waste management documentation and mandatory energy forms signatures required, and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. 4. Final third-party special/deputy inspector reports. and any structural observation reports, or surveyor or civil engineering final reports required at final inspection. April 16, 2021: 1. Building-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural scope of work per structural plans and detail specifications -not ready. 3. Inform Enrique, contractor representative, waste management documentation and mandatory energy forms signatures required, and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. 155592-2021 Cancelled Tim Kersch Reinspection Inspection No No Reinspection Incomplete Page 13 of 18 Permit Type: BLDG-Residential Work Class: Alteration Status; Closed -Fina led Application Date: 09/13/2019 Issue Date: 04/23/2020 Expiration Date: 09/13/2021 IVR Number: 21744 Owner: TRUST PAHL ARCHIE W JR FAMILY Subdivision: WILSONIA TRACT Addrnss: 2717 WILSON ST CARLSBAD, CA 92008-1530 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Plumbing Fina I BLDG-Mechanical Final Friday, April 23, 2021 COMMENTS April 16, 2021: 1. Building-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural scope of work per structural plans and detail specifications -not ready. 3. Inform Enrique, contractor representative, waste management documentation and mandatory energy forms signatures required, and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. 4. Final third-party special/deputy inspector reports, and any structural observation reports, or surveyor or civil engineering final reports required at final inspection. April 16, 2021 1. Building-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural scope of work per structural plans and detail specifications -not ready. 3. Inform Enrique, contractor representative, waste management documentation and mandatory energy forms signatures required. and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. April 16, 2021: 1. Building-new single-family dwelling deficiencies. 2. Mechanical electrical plumbing and structural scope of work per structural plans and detail specifications -not ready. 3. Inform Enrique, contractor representative, waste management documentation and mandatory energy forms signatures required, and all new single family dwelling work per architectural and structural plans need to be completed prior final inspection. Passed No No No Page 12 of 18 Permit Type: BLDG-Residential Work Class: Alteration Status: Closed -Finaled Application Date: 09/13/2019 Owner: TRUST PAHL ARCHIE W JR FAMILY Issue Date: 04/23/2020 Subdivision: WILSONIA TRACT Expiration Date: 09/13/2021 IVR Number: 21744 Address: 2717 WILSON ST CARLSBAD, CA 92008-1530 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS March 11, 2021: (virtual inspection). ***Building deficiencies*** 1. Relocated existing electrical main service panel to new garage area new electrical Panel Upgrade requires: a) grounding rods, with continuous electro grounding conductor wire, not installed-not approved. b) Cold water grounding bond wire and clamp, not installed. c) New electrical ground wire, not landed on bus bar, inside new electrical main service panel. d) no SDGE work order on site to be verified for new location and height requirements for new electrical main service panel. e) additional corrections may follow. March 15, 2021: No Building/panel upgrade deficiencies 1. Relocated existing electrical main service panel to new garage area new electrical Panel Upgrade requires: a) grounding rods, with continuous electro grounding conductor wire installed-approved. b) Cold water grounding bond wire and clamp installed. c) New electrical ground wire, landed on bus bar, inside new 200 amp. electrical main service panel. d) SDGE work order on site and verified for new location and height requirements for new 200 amp. electrical main service panel. e) no additional corrections. f) released new to 200 amp. panel upgrade to SDGE. 04/16/2021 04116/2021 BLDG-Final Inspection 155115-2021 Failed Tony Alvarado Friday, April 23, 2021 Passed No Yes Reinspection Incomplete Page 11 of 18 Permit Type: BLDG-Residential Work Class: Alteration Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item Application Date: 09/13/2019 Owner: TRUST PAHL ARCHIE W JR FAMILY Issue Date: 04/23/2020 Subdivision: WILSONIA TRACT Expiration Date: 09/13/2021 IVR Number: 21744 Inspection No. COMMENTS Inspection Status Addrnss: 2717 WILSON ST CARLSBAD, CA 92008-1530 Primary Inspector Reinspection Inspection Passed BLDG·Building Deficiency March 11, 2021: (virtual inspection). •**Building deficiencies*"" No 03/15/2021 03/15/2021 BLDG-33 Service Change/Upgrade Friday, April 23, 2021 1. Relocated existing electrical main service panel to new garage area new electrical Panel Upgrade requires: a) grounding rods, with continuous electro grounding conductor wire, not installed•not approved. b) Cold water grounding bond wire and clamp, not installed. c) New electrical ground wire, not landed on bus bar, inside new electrical main service panel. d) no SDGE work order on site to be verified for new location and height requirements for new electrical main seivice panel. e) additional corrections may follow. 152706-2021 Passed Tony Alvarado Complete Page 10 of 18 Permit Type: BLDG-Residential Work Class: Alteration Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item Application Date: 09/13/2019 Owner: TRUST PAHL ARCHIE W JR FAMILY Issue Date: 04/23/2020 Subdivision: WILSONIA TRACT Expiration Date: 09/13/2021 IVR Number: Inspection No. COMMENTS 21744 Inspection Status Address: 2717 WILSON ST CARLSBAD, CA 92008-1530 Primary Inspector Reinspection Inspection Passed BLDG-Building Deficiency January 25, 2021: (virtual inspection). "No pool deficiencies". Yes 02/04/2021 02/04/2021 BLDG-16 lnsulatlon Checklist Item 1. lnsulation/title-24 wall, ceilings and perimeter foam insulation at all wall penetration/openings, scope of work-approved. 2. All rough framing combination minor corrections addressed for the following: a) missing plumbing bracing/strapping-approved. b) exterior wall sole plate-anchor bolts missing at three locations-approved. c) truss metal clip connectors missing in a few locations, scope of work, scope of rough combination work per architectural/structural engineer's plan and design specifications-approved. 149776-2021 COMMENTS Passed Tony Alvarado BLDG-Building Deficiency February 4, 2021: (virtual inspection). "No Building deficiencies". 02/09/2021 02109/2021 BLDG~17 Interior Lath/Drywall Checklist Item 1. lnsulation/title-24 wall, ceilings and perimeter foam insulation at all wall penetration/openings, scope of work-approved. 2. All rough framing combination minor corrections addressed for the following: a) missing plumbing bracing/strapping-approved . b) exterior wall sole plate-anchor bolts missing at three locations-approved. c) truss metal clip connectors missing in a few locations, scope of work, scope of rough combination work per architectural/structural engineer's plan and design specifications-approved. 150136-2021 Passed Tony Alvarado COMMENTS BLDG-Building Deficiency February 9, 2021: (virtual inspection). 03/11/2021 03/11/2021 BLDG-33 Service Change/Upgrade Friday, April 23, 2021 --------·--------------- 1. Interior drywall type and drywall nailing pattern, scope of work-approved. 152504-2021 Falled Tony Alvarado Complete Passed Yes Complete Passed Yes Reinspection Incomplete Page 9 of 18 Permit Type: BLDG-Residential Work Class: Alteration Application Date: 09/13/2019 Own,,r: TRUST PAHL ARCHIE W JR FAMILY Status: Scheduled Date 12/16/2020 01/2812021 02/03/2021 Issue Date: 04/23/2020 Closed -Finaled Expiration Date: 09/13/2021 IVR Number: 21744 Subdivision: WILSONIA TRACT Addrnss: 2717 WILSON ST CARLSBAD, CA 92008-1530 Actua I Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency November 6, 2020: Partial roof sheathing Yes nailing inspection. 1. Roof sheathing type/nailing pattern, roof dwelling house area (only) -dry in due to rain event -approved. 12/1612020 BLDG-14 146330-2020 Partial Pass Tony Alvarado Reinspection Incomplete Frame/Steel/Bolling/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency November 6, 2020: Partial roof sheathing Yes nailing inspection. 1. Roof sheathing type/nailing pattern, roof dwelling house area (only) -dry in due to rain event -approved. BLDG-Building Deficiency December 16th, 2020: Yes 1. Exterior shearwall nailing pattern not correct, shearwall,nails missing, A-35 metal clips missing nails, missing A-35 hardware clips in some areas, (2) qty. holddowns missing at existing wall, lower level remodel rear house wall area. 2. Contractor Enrique will fix few areas that need to be addressed, and next inspection will be verifying redo shear wall/hold downs work by virtual inspection. 3. OK to continue stucco lath paper and roof felt paper, to dry-in structure. 01/28/2021 BLOG-84 Rough 149342-2021 Partial Pass Tony Alvarado Re inspection Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 02/03/2021 BLDG-16 Insulation 149773-2021 Passed Tony Alvarado Complete Friday, April 23, 2021 Page 8 of 18 Permit Type: BLDG-Residential Work Class: Alteration Status: Closed -Finaled Application Date: 09/13/2019 Owner: TRUST PAHL ARCHIE W JR FAMILY Issue Date: 04/23/2020 Subdivision: WILSONIA TRACT Expiration Date: 09/13/2021 IVR Number: 21744 Address: 2717 WILSON ST CARLSBAD, CA 92008-1530 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection 10/27/2020 11/06/2020 BLDG-Building Deficiency October 9, 2020: 1. Rear elevation patio footings and slab steel reinforcement, per engineered plans, details and specifications-approved. 2. Verified deputy inspectors report for Dowling into existing slab -approved. 10/27/2020 BLDG-11 141925-2020 Passed Tony Alvarado Foundatlon/Ftg/Plers (Rebar) Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS October 27th, 2020: 1. Footings steel reinforcement rebar, attached open lattice patio structure, per structural engineer plans and detail specifications-approved . September 24, 2020: (Failed). Spoke to project superintendent Enrique - Certification required prior to concrete pour are still not provided at time of footing slab inspection. Informed and discussed with geotechnical engineer second time, to verify city requirements prior to footing/slab Final inspection sign-offs. Scope of work for foundation/slab footing reinforcement steel work -pending approval items: 1. height certification form required-per a civil engineer/surveyor, (prior to concrete pour). 2. Property line setbacks to proposed footing/foundation forms for new garage structure-per a civil engineer/surveyor, (Prior to concrete pour). 3. Pad certification per soils engineer foI footing Bottoms and slab/foundation , (Prior to concrete pour). 11/06/2020 BLDG-14 143139-2020 Partial Pass Tony Alvarado Frame/Steel/Bolting/We !ding (Decks) Checklist Item BLDG-Building Deficiency COMMENTS November 6, 2020: Partial roof sheathing nailing inspection. 1. Roof sheathing type/nailing pattern, roof dwelling house area (only) -dry in due to rain event-approved. BLDG-15 Roof/ReRoof (Patio) 143138-2020 Partial Pass Tony Alvarado Friday, April 23, 2021 -------···---···-----· Yes Complete Passed Yes No Reinspection Incomplete Passed Yes Reinspection Incomplete Page 7 of 18 Permit Type: BLDG-Residential Work Class: Alteration Status: Closed -Finaled Application Date: 09/13/2019 Own1>r: TRUST PAHL ARCHIE W JR FAMILY Issue Date: 04/23/2020 Subdivision: WILSONIA TRACT Expiration Date: 09/13/2021 IVR Number: 21744 Address: 2717 WILSON ST CARLSBAD, CA 92008-1530 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency Friday, April 23, 2021 COMMENTS September 18, 2020: Scope of work for foundation/slab footing reinforcement steel work -pending approval items: 1. height certification form required-per a civil engineer/surveyor, (prior to concrete pour). 2. Property line setbacks to proposed footing/foundation forms for new garage structure-per a civil engineer/surveyor, (Prior to concrete pour). 3. Pad certification per soils engineer for footing Bottoms and slab/foundation , (Prior to concrete pour). September 21, 2020: (Failed). Scope of work for foundation/slab footing reinforcement steel work -pending approval items: 1. height certification form required-per a civil engineer/surveyor, (prior to concrete pour). 2. Property line setbacks to proposed footing/foundation forms for new garage structure-per a civil engineer/surveyor, (Prior to concrete pour). 3. Pad certification per soils engineer for footing Bottoms and slab/foundation , (Prior to concrete pour). September 24, 2020: (Failed). Spoke to project superintendent Enrique - Certification required prior to concrete pour are still not provided at time of footing slab inspection. Informed and discussed with geotechnical engineer second time, to verify city requirements prior to footing/slab Final inspection sign-offs. Scope of work for foundation/slab footing reinforcement steel work -pending approval items: 1. height certification form required-per a civil engineer/surveyor, (prior to concrete pour). 2. Property line setbacks to proposed footing/foundation forms for new garage structure-per a civil engineer/surveyor, (Prior to concrete pour). 3. Pad certification per soils engineer for footing Bottoms and slab/foundation , (Prior to concrete pour). Passed Yes No No Page 6 of 18 Permit Type: BLDG-Residential Work Class: Alteration Status: Closed -Finaled Scheduled Actual Inspection Type Date Start Date 10/0912020 10109/2020 BLDG-11 Friday, April 23, 2021 Foundatlon/Ftg/Plers (Rebar) Application Date: 09/13/2019 Own<,r: TRUST PAHL ARCHIE W JR FAMILY lssu~ Date: 04/23/2020 Subdivision: WILSONIA TRACT Expiration Date: 09/13/2021 Address: 2717 WILSON ST CARLSBAD, CA 92008-1530 IVR Number: 21744 Inspection No. Inspection Primary Inspector Reinspection Inspection Status 140565-2020 Partlal Pass Tony Alvarado Relnspection Incomplete Page 5 of 18 ='r:;"-!!Jz3: -l· *d * ~""'-~~t." -z~ ~.::; r~ * "~,: 1 * %~;£~-:?£;;,½! ~ ~ ·: .· ., . BE.RMiltlNSPECTION'IUATOR:V fq1;~ft. II ~9::J~j . 50''' ·. ~· Permit Type: BLDG-Residential Work Class: Alteration Status: Closed -Finaled Application Date: 09/13/2019 Owm,r: TRUST PAHL ARCHIE W JR FAMILY Issue Date: 04/23/2020 Expiration Date: 09/13/2021 IVR Number: 21744 Subdivision: WILSONIA TRACT Address: 2717 WILSON ST CARLSBAD, CA 92008-1530 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Friday, April 23, 2021 BLDG-11 140248-2020 Cancelled Tony Alvarado F ou n datlo n/Ftg/Plers (Robar) Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS September 21, 2020: (Failed). Scope of work for foundation/slab footing reinforcement steel work -pending approval items: 1. height certification form required-per a civil engineer/surveyor, (prior to concrete pour). 2. Property line setbacks to proposed footing/foundation forms for new garage structure-per a civil engineer/surveyor, (Prior to concrete pour). 3. Pad certification per soils engineer for footing Bottoms and slab/foundation , (Prior to concrete pour). September 24, 2020: (Failed). Spoke to project superintendent Enrique - Certification required prior to concrete pour are still not provided at time of footing slab inspection. Informed and discussed with geotechnical engineer second time, to verify city requirements prior to footing/slab Final inspection sign-offs. Scope of work for foundation/slab footing reinforcement steel work -pending approval items: 1. height certification form required-per a civil engineer/surveyor, (prior to concrete pour). 2. Property line setbacks to proposed footing/foundation forms for new garage structure-per a civil engineer/surveyor, (Prior to concrete pour). 3. Pad certification per soils engineer for footing Bottoms and slab/foundation , (Prior to concrete pour). September 18, 2020: Scope of work for foundation/slab footing reinforcement steel work -pending approval items: 1. height certification form required~ per a civil engineerfsurveyor, (prior to concrete pour). 2. Property line setbacks to proposed footing/foundation forms for new garage structure-per a civil engineer/surveyor, (Prior to concrete pour). 3. Pad certification per soils engineer for footing Bottoms and slab/foundation , (Prior to concrete pour). Reinspectlon Incomplete Passed No No Yes Page 4 of 18 ~--* * --,;_-•<-* %:;,, -Vfik=.:,,S. -,⇒=,-/{; = y 0 ">0 * "~ ct=~0 00=0 --~ ~~r '. ' Jgaifmtitlse~attl Rl&T:M' ~tfilli('~fiills'f ! ,,,,,", ~r:i: Permit Type: BLDG-Residential Work Class: Alteration Status; Closed -Finaled Application Date: 09/13/2019 Issue Date: 04/23/2020 Expiration Date: 09/13/2021 IVR Number: 21744 Own<>r: TRUST PAHL ARCHIE W JR FAMILY Subdivision: WILSONIA TRACT Addr,ess: 2717 WILSON ST CARLSBAD, CA 92008-1530 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reins·pection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency 10/07/2020 10/07/2020 Friday, April 23, 2021 COMMENTS September 18, 2020: Scope of work for foundation/slab footing reinforcement steel work -pending approval items: 1. height certification form required-per a civil engineer/surveyor, (prior to concrete pour). 2. Property line setbacks to proposed footing/foundation forms for new garage structure-per a civil engineer/surveyor, (Prior to concrete pour). 3. Pad certification per soils engineer for footing Bottoms and slab/foundation, (Prior to concrete pour). September 24, 2020: (Failed). Spoke to project superintendent Enrique - Certification required prior to concrete pour are still not provided at time of footing slab inspection. Informed and discussed with geotechnical engineer second time, to verify city requirements prior to footing/slab Final inspection sign-offs. Scope of work for foundation/slab footing reinforcement steel work-pending approval items; 1. height certification form required-per a civil engineer/surveyor, (prior to concrete pour). 2. Property line setbacks to proposed footing/foundation forms for new garage structure-per a civil engineer/surveyor, (Prior to concrete pour). 3. Pad certification per soils engineer for footing Bottoms and slab/foundation , (Prior to concrete pour). September 21, 2020: (Failed). Scope of work for foundation/slab footing reinforcement steel work -pending approval items: 1. height certification form required-per a civil engineer/surveyor, (prior to concrete pour). 2. Property line setbacks to proposed footing/foundation forms for new garage structure-per a civil engineer/surveyor, (Prior to concrete pour). 3. Pad certification per soils engineer for footing Bottoms and slab/foundation , (Prior to concrete pour). Passed Yes No No Page 3 of 18 Permit Type: BLDG-Residential Work Class: Alteration Status: Closed -Finaled Application Date: 09/13/2019 Owne•r: TRUST PAHL ARCHIE W JR FAMILY Issue Date: 04/23/2020 Expiration Date: 09/13/2021 IVR Number: 21744 Subdivision: WILSONIA TRACT Addmss: 2717 WILSON ST CARLSBAD, CA 92008-1530. Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS September 21, 2020: (Failed). Scope of work for foundation/slab footing reinforcement steel work -pending approval items: 1. height certification form required-per a civil engineer/surveyor, (prior to concrete pour). 2. Property line setbacks to proposed footing/foundation forms for new garage structure-per a civil engineer/surveyor, (Prior to concrete pour). 3. Pad certification per soils engineer for footing Bottoms and slab/foundation, (Prior to concrete pour). September 18, 2020: Scope of work for foundation/slab footing reinforcement steel work -pending approval items: 1. height certification form required-per a civil engineer/surveyor, (prior to concrete pour). 2. Property line setbacks to proposed footing/foundation forms for new garage structure-per a civil engineer/surveyor, (Prior to concrete pour). 3. Pad certification per soils engineer for footing Bottoms and slab/foundation , (Prior to concrete pour). 09/24/2020 09/24/2020 BLDG-11 Foundatlon/Ftg/Plers (Rebar) 139167-2020 Failed Tony Alvarado Friday, April 23, 2021 Passed No Yes Reinspectlon Incomplete Page 2 of 18 Building Permit Inspection History Finaled (city of Carlsbad Permit Type: Work Class: Status: Scheduled Date 08127/2020 09/10/2020 09/18/2020 09/21/2020 BLDG-Residential Alteration Closed -Finaled Actual Inspection Type Start Date 08127/2020 BLOG-SW-Pre-Con Checklist Item Application Date: Issue Date: Expiration Date: IVR Number: Inspection No. 136920-2020 COMMENTS 09/13/2019 04/23/2020 09/13/2021 21744 Inspection Status Owrwr: TRUST PAHL ARCHIE W JR FAMILY Subdivision: WILSONIA TRACT Address: 2717 WILSON ST CARLSBAD, CA 92008-1530 Primary Inspector Reinspection Inspection Partial Pass Tony Alvarado Relnspectlon Incomplete Passed BLDG•Building Deficiency August 27, 2020: Yes 09/10/2020 BLDG-21 Underground/Underflo or Plumbing Checklist Item 1. Preconstruction meeting for SWPPS, BMPs and all erosion control measures in place and intact at all times of construction. Spoke to contractor Enrique and informed regarding stormwater control measures. 2. Discussed with owner/builder and contractor Henrique regarding letter architect stating removal of most exterior load bearing walls, except for two walls at rear elevation bedroom area. 137660-2020 Passed Tony Alvarado COMMENTS BLDG-Building Deficiency September 1 0, 2020: 09/18/2020 BLOG-11 Foundatlon/Ftg/Plers (Rebar) Checklist Item 1. Underground waste plumbing lines under test,-approved. 136697-2020 Partial Pass Tony Alvarado COMMENTS BLDG-Building Deficiency September 18, 2020: 09/21/2020 BLOG-11 Foundation/Fig/Piers (Rebar) Scope of work. for foundation/slab footing reinforcement steel work. -pending approval items: 1. height certification form required-per a civil engineer/surveyor, (prior to concrete pour). 2. Property line setbacks to proposed footing/foundation forms for new garage structure-per a civil engineer/surveyor, (Prior to concrete pour). 3. Pad certification per soils engineer for footing Bottoms and slab/foundation , (Prior to concrete pour). 138777-2020 Failed Tony Alvarado Complete Passed Yes Relnspection Incomplete Passed Yes Reinspection Incomplete Friday, April 23, 2021 Page 1 of 18 ✓• EsG1I A SA.f.Ebuilt'Ccm--,p,>ny DATE: April 21, 2020 JURISDICTION: CARLSBAD PLAN CHECK#.: CBR2019-2546 SET: III PROJECT ADDRESS: 2717 WILSON STREET PROJECT NAME: SFD REMODEL FOR VEIGA ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: t.{ p_,/ }){) (by[,n) Email: Mail Telephone Fax In Person ~ REMARKS: Set Ill partial submittal included only sheets 5-2.1 and 5-4.0. These were slip sheeted onto set II received on 2/21. By: Abe Doliente (for BD) EsGil 4/14/20 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 •. DATE: 3/10/2020 JURISDICTION: CARLSBAD PLAN CHECK#.: CBR2019-2546 ✓• EsG1I A SAFEbuHfCompany SET: II PROJECT ADDRESS: 2717 WILSON STREET PROJECT NAME: SFD REMODEL FOR VEIGA □LICANT /JuRis. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. L8] The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. L8] The applicant's copy of the check list has been sent to: ANDREW CARLOS D EsGil staff did not advise the applicant that the plan check has been completed. L8] EsGil staff did advise the applicant that the plan check has been completed. Person contacted: ANDREW Telephone#: 760 579 3996 Date contacted: .31Jojao (bydc)) Email: INFO@ANDREWCARLOSARCHITECT.COM Mail Telephone 0 REMARKS: By: Bert Domingo EsGil Fax In Person Enclosures: 2/21/2020 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 CARLSBAD CBR2019-2546 3/10/2020 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations. (California Business and Professions Code). PLUMBING 9. Show water heater size (1 st hour rating), type, and location on plans. Note: For both new dwellings and additions the Energy Standards (150.0(n)) requires a gas input rating of 200,000 Btu for both tank and instantaneous gas water heaters. (Also) Provide a gas piping design for the gas system. Please show the size of the pipes for each outlet. Also, please show the distance from the meter for each outlet. An instantaneous water heater is shown on the plans. Please include a gas pipe sizing design (isometric or pipe layout) for all gas loads. 10. The gas pipe sizing for a tank type water heater shall be based upon a minimum 199,000 Btu gas input rating. Energy Standards 150.0(n). CARLSBAD CBR2019-2546 3/10/2020 MISCELLANEOUS 13. Title 24 calculations did not seem to have included the requirements of the new exterior walls. It seems not submitted with this package. 14. Please show the recommended insulation for the roofs and the walls on the sections. This will be checked when item 13 is met. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bert Domingo at EsGil. Thank you. DATE: 9/21/2019 JURISDICTION: CARLSBAD PLAN CHECK#.: CBR2019-2546 ✓• EsG1I A '.)Af-Ebwlt Compan/ SET: I PROJECT ADDRESS: 2717 WILSON STREET PROJECT NAME: SFD REMODEL FOR VEIGA □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: ANDREW CARLOS D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: ANDREW Date contacted".'~ i cj (bY1 G,) Email: / t_ Mail Telephone' ~x In Person Telephone#: 760 579 3996 INFO@ANDREWCARLOSARCHITECTS.COM CJ REMARKS: 1 By: Bert Domingo EsGil Enclosures: 9/17/2019 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) :560-1468 ♦ Fax (858) 560-1576 CARLSBAD CBR2019-2546 9/21/2019 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR2019-2546 JURISDICTION: CARLSBAD PROJECT ADDRESS: 2717 WILSON STREET FLOOR AREA: REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 9/21/2019 FOREWORD (PLEASE READ): STORIES: HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 9/17/2019 PLAN REVIEWER: Bert Domingo This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. CARLSBAD CBR2019-2546 9/21/2019 PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations. (California Business and Professions Code). STRUCTURAL 4. Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. 5. Please provide evidence that the engineer-of-record (or architect) has reviewed the truss calculation package prepared by others (i.e., a "review" stamp on the truss calculations or a letter). CBC Section 107 .3.4.1. ELECTRICAL 6. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If the service is over 200 amperes, submit a single line diagram, panel schedules, and provide service load calculations. 7. Note on the plans that receptacle outlet locations will comply with CEC Article 210.52. CARLSBAD CBR2019-2546 9/21/2019 8. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). b) Weather resistant type for receptacles installed in damp or wet locations (outside). c) Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(A): Kitchens, laundry areas, family, living, bedrooms, dining, halls, etc. d) GFCI protected outlets for locations described in NEC 210.8(A): Laundry areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors, within 6' of a sink, etc. PLUMBING 9. Show water heater size (1 st hour rating), type, and location on plans. Note: For both new dwellings and additions the Energy Standards (150.0(n)) requires a gas input rating of 200,000 Btu for both tank and instantaneous gas water heaters. (Also) Provide a gas piping design for the gas system. 10. An instantaneous water heater is shown on the plans. Please include a gas pipe sizing design (isometric or pipe layout) for all gas loads. a) The gas pipe sizing for a tank type water heater shall be based upon a minimum 199,000 Btu gas input rating. Energy Standards 150.0(n). 11. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8 GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 1.8 GPM of flow. CPC Sections 407, 408, 411, 412. 12. Specify on the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California SB407. CARLSBAD CBR2019-2546 9/21/2019 MISCELLANEOUS 13. Title 24 calculations did not seem to have included the requirements of the new exterior walls. 14. Please show the recommended insulation for the roofs and the walls on the sections. 15. R3's: For the following types of projects, a minimum of one "EVSE (Electric Vehicle Supply Equipment) ready space" shall be installed: • New one-and two-family dwellings • Townhouse style with attached garages • Major residential renovations (defined as renovations/additions having a valuation of $60,000 or more) • Any project with an electrical service upgrade (including upgrades for PV installation) The "EVSE ready space" shall have the following: Panel capability, 40A 2 pole breaker, 1" raceway, No. 8 conductors installed to the anticipated charger location. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bert Domingo at EsGil. Thank you. CARLSBAD CBR2019-2546 9/21/2019 /DO NOT PAY-THIS IS NOT AN INVOICE/ VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PREPARED BY: Bert Domingo BUILDING ADDRESS: 2717 WILSON STREET BUILDING OCCUPANCY: R 3 BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier CTY ESTIMATE Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code CB By Ordinance 1997 USC Building Permit Fee 1997 UBC Plan Check Fee Type of Review: D Repetitive Fee • Repeats 0 Complete Review D Other D Hourly EsGII F•• PLAN CHECK#.: CBR2019-2546 DATE: 9/21/2019 Reg . VALUE ($) Mod. 113,284 113,284 D Structural Only $439.241 Comments: In. addition to the above fee, an additional fee of$ is due ( hour@ $ /hr.) for the CalGreen review. Sheet 1 of 1 □ «~~ ~ C ITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK REVIEW CHECKLIST P-28 DATE: 9/30/19 PROJECT NAME: ROOF/REMODEL Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.Qov PROJECT ID: PLAN CHECK NO: CBR2019-2546 SET#: 1 ADDRESS: 2717 WILSON APN: 156-130-21-00 T~i~ ~Ian check review is complete and has been AP~n OVE · by he rJ.ANNING D1v1s1on. FEB 2 0 2020 By: ALYSSA BARMAN Cl ) A Final Inspection by the PLANNING Division is requ·re(f ,CJ Yes , ~ No l You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or--incorrect are listed on I the attached checklist. Please resubmit amended plans as required. FEB 2 0 2020 Plan Check Comments have been sent to: I NFO@ANDREWCARLOSARCH ITECTS.COM en r u -l, • ... • ...., .. o BUil D'I ~ ~1 c::ic f\J For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 76o-602-4610 760-602-2750 760-602-4665 ~ Alyssa Barman 760-602-2709 Alyssa. Bi;!rman~ca rlsbadca. gov Remarks: 1,925 SF REMODEL TO EXTING DWELLING. REROOFING AND PATIO COVERS. REVIEW#: 1 2 3 1:8:1 □ □ 1:8:1 □ □ 1:8:1 □ □ 1:8:1 □ □ 1:8:1 □ □ Plan Check No. CBC2019-2546 Address 2717 WILSON ST Date 9/30/19 Review # 1 Planner ALYSSA BARMAN Phone (760) 602-2709 APN: 156-130-21-00 Type of Project & Use: ROOF/REMODEL Net Project Density: DU/AC Zoning: R-1 General Plan: R-4 Facilities Management Zone: 1 CFD (in/out) #_Date of participation: __ Remaining net dev acres: __ (For non-residential development: Type of land use created by this permit: __ ) Legend: cgJ Item Complete D Item Incomplete -Needs your action Environmental Review Required: YES □ NO □ TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES □ NO □ TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: __ Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES D NO 18:t CA Coastal Commission Authority? YES D NOD If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Habitat Management Plan Data Entry Completed? YES □ NO □ If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Energov lnclusionary Housing Fee required: YES D NO D (Effective date of lnclusionary Housing Ordinance -May 21, 1993.) Data Entry Completed? YES □ NO □ For construction of inclusionary units, email notification provided to HNS?: YES D NO D (Email Susan Steinkemp in HNS with project number and contact info) 1:8:] D D Housing Tracking Form (form P-20) completed: YES D NO D N/A D P-28 Page 2 of 4 07/11 Site Plan: 181 □ □ 181 □ □ 181 □ □ 181 □ □ 181 □ □ □□□ 181 □ □ □□□ □□□ P-28 Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. City Council Policy 44 -Neighborhood Architectural Design Guidelines 1. Applicability: YES O NO 0 2. Project complies: YES D NOD Zoning: 1. Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: Required __ Shown Required Shown Required __ Shown Required Shown Required __ Shown __ 2. Accessory structure setbacks: Front: Required __ Shown __ Interior Side: Required __ Shown Street Side: Required __ Shown __ Rear: Required __ Shown Structure separation: Required __ Shown __ 3. Lot Coverage: Required 40% Shown PLEASE UPDATE PLANS TO SHOW LOT COVERAGE CALCULATION. LOT COVERAGE IS TO BE CALCULATED AS THE TOTAL SQUARE FOOTAGE OF THE FOOTPRINT OF STRUCTURES (I.E. THE EXISTING RESIDENCE, GARAGE, ACCESSORY DWELLING UNIT, PROPOSED PATIO COVERS, AND EEXISTING STORAGE) DIVIDED BY THE TOTAL LOT SIZE. Lot coverage calculation updated on Sheet T-1 4. Height: Required __ Shown 5. Parking: Spaces Required __ Shown (breakdown by uses for commercial and industrial projects required) IN ORDER TO SHOW COMPLIANCE WITH THE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST, PLEASE SHOW WHERE EVSE READY PARKING SPACE IS TO BE LOCATED. PLEASE FIND THE ELECTRIC VEHICLE ORDINANCE HERE: https://www.carlsbadca.gov/services/depts/pw/environment/cap/ordinances.asp EVSE receptical has been added to the garage -Sheet A2.3 Residential Guest Spaces Required __ Shown __ Additional Comments: Page 3 of 4 07/11 1. PLEASE PROVIDE RESIDENTIAL BUILDING RECORD OR COPY OF APPROVED PLANS/PERMITS FOR EXISTING TWO CAR GARAGE AT THE REAR OF THE PROPERTY AND EXISTING ACCESSORY DWELLING UNIT. OR IF UNPERMITTED, PLEASE SEE THE BUILDING DEPARTMENT FOR BUILDING APPLICATIONS. The county building record does not show any permits for the existing ADU and 2-Car Garage and Storage buildings. These structures will be removed (see A 1.1) and a new 3-car garage will be constructed to meet parking requirements. See A 1.1 and Floor plan A2. 1. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE P-28 Page 4 of 4 07111 ✓• EsG1I DATE: 9/21/2019 JURISDICTION: CARLSBAD PLAN CHECK#.: CBR2019-2546 PROJECT ADDRESS: 2717 WILSON STREET PROJECT NAME: SFD REMODEL FOR VEIGA SET: I D APPLICANT D JURIS. R r-,_. F= ' i D FEB 2 0 2020 D The plans transmitted herewith have been corrected where n~tessary and sub t Rtially comply with the jurisdiction's codes. Lu .i : , ' ' 1 D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Es Gil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person . ~ The applicant's copy of the check list has been sent to: ANDREW CARLOS D Es Gil staff did not advise the applicant that the plan check has been completed . ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted : ANDREW Telephone#: 760 579 3996 Date contacted: (by: ) Email: INFO@ANDREWCARLOSARCHITECTS.COM Mail Telephone 0 REMARKS: By: Bert Domingo EsGil Fax In Person Enclosures: 9/17/2019 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 J C cifyof Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST 8-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the build ing permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool A If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. A Details on CAP ordinance requirements are available on the city's website. A A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. Project Name/Building Permit No.: Property Address/APN: Applicant Name/Co.: Applicant Address: Contact Phone: _V_E"_l_~_A-_vl_~_, ~_(:_.c.,u_C._~--BP No.: C6~a~ R :}__~<-/lo I S"c, I !,O -Z. \ o o Z 7 l 7 IN\L c;o,u -e.:r: ~ ,.. sr.::r 2,_ -7 ! s1 Contact Email: Contact information of person completing this checklist (if different than above): Name: Company name/address: AN'-D~ ~L.uscontactPhone: ~kVLL0~ ,ArtCH-l'tt.:C(~ntactEmail: ,~?<?_Qvtd.V.P~cCjvlo ~ QV'C.1A11-a:..+-, Co~ Applicant Signature: -_.,;;;;;;;;;;;;;;;;;;;;; ... iiiiiiiiii~Ci=:::::~~~----Date: B-50 Page 1 of 6 Revised 08/19 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet: $ J , cl]). Su 3 • 7-S ,- ~esidential □ New construction ~ Additions and alterations: □ BPV < $60,000 □ BPV ~ $60,000 □ Electrical service panel upgrade only ~ BPV ~ $200,000 D Nonresidential □ New construction □ Alterations: □ BPV ~ $200,000 or additions~ 1,000 square feet □ BPV ~ $1 ,000,000 □ ~ 2,000 sq. ft. new roof addition 1. Energy Efficiency A high-rise residential building is 4 or more stories, including a Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use 2A, 3A, 18, 28, 4A 38,4A N/A N/A All residential additions and alterations 1A, 4A 4A 1-2 family dwellings and townhouses with attached garages only *Multi-family dwellings only where interior finishes are removed 1A, 4A* 18, 4A* and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed 1 B, 28, 38, 48 and 5 18, 5 18,28,5 Building alterations of~ 75% existing gross floor area 28, 5 1 B also applies if BPV ~ $200,000 Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for more information when completing this section. A )Qr Residential addition or alteration ?; $60,000 building permit valuation. /' See CMC section 18.30.190. Year Built Single-family Requirements )(' Before 1978 Select one: Kl"Duct sealinq ~tic insulation ' (:ool roof D 1978 and later Select one: D Lighting package D Water heating Package D Between 1978 and 1991 □ 1992 and later D N/A _________ _ D Exception: Home energy score <! 7 (attach certification) Multi-family Requirements D Attic insulation Select one: D Duct sealinq D Attic insulation D Cool roof Select one: D Lighting package D Water heating package B. D Nonresidential* new construction or alterations?; $200,000 building permit valuation, or additions ?; 1,000 square feet □ N/A Updated 8/ I 5/20 19 L 2 City of Carlsbad Climate Action Plan Consistency Checklist See CMC 18.21.155 and CALGreen Appendix AS, Division AS.2-Energy Efficiency. A5.203.1.1 Choose one: D .1 Outdoor lighting D .2 Warehouse dock seal doors D .3 Restaurant seNice water heating (comply with California Energy Code section 140.5, as amended) D N/A. _________ _ D .4 Daylight design PAFs D .5 Exhaust air heat recovery A5.203.1.2.1 Choose one as applicable: D .95 Energy budget D .90 Energy budget D N/A A5.211.1 .. D On-s~e renewable energy D N/A A5.21 1.3** D Green power (if offered by local utility provider, 50% minimum renewable sources) D N/A A5.212.1 D Elevators and escalators D N/A A5.213.1 D Steel framing D N/A * Includes hotels/motels and high-rise residential buildings ** For alterations;,; $1,000,000 BPV and affecting > 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with CMC 18.30.130 instead. 2. Photovoltaic Systems A. D Residential new construction (for low-rise residential building permit applications submitted after 1/1 /20). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (28 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(8) (high-rise residential) or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #d.u. Calculated kWdc* sheets if necessary) Total System Size: kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.) *Formula calculation where CFA = conditional floor area, #du = number of dwellings per plan type If proposed system size is less than calculated size, please explain. Exception D D D D kWdc 8. D Nonresidential new construction or alterations ~$1 ,000,000 8PV and affecting ~75% existing floor area, or addition that increases roof area by ~2,000 square feet Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: □ Gross Floor Area (GFA) Method GFA: D If< 1O,OOOs.f. Enter: 5 kWdc Min. System Size: D If;?: 1O,OOOs.f. calculate: 15 kWdc x (GFA/1O,OOO) ** kWdc **Round building size factor to nearest tenth, and round system size to nearest whole number. □ Time-Dependent Valuation Method Updated 8/15/20 19 3 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:*** ______ x .80= Min. system size: _____ kWdc ***Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A. D Residential and hotel/motel new construction Please refer to CMC sections 18.30.1 50 and 18.30.170 when completing this section. D For systems serving individual dwelling units choose one: D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) D Heat pump water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1(c) 14 (low-rise residential) D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors D Exception: D For systems serving multiple dwelling units, install a central water-heating system with all of the fo llowing: D Gas or propane water heating system D Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low- rise residential) D Solar water heating system that is either: D .20 solar savings fraction D .15 solar savings fraction, plus drain water heat recovery D Exception: B. D Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. D Water heating system derives at least 40% of its energy from one of the following (attach documentation): D Solar-thermal D Photovoltaics D Recovered energy D Water heating system is (choose one): D Heat pump water heater D Electric resistance water heater(s) □Solar water heating system with .40 solar savings fraction D Exception: Updated 8/15/2019 4 City of Carlsbad Climate Action Plan Consistency Checklist 4. Electric Vehicle Cha in A. TI Residential New construction and major alterations* ~se refer to Carlsbad Ordinance CMC section 18.21.140 when com letin this section. Oti and two-family residential dwelling or townhouse with attached garage: ' One EVSE Ready parking space required □Exception : □ Multi-family residential· □ Exception · Total Parking Spaces EVSE Spaces Proposed Capable I Readv I I I Calculations: Total EVSE spaces= .10 x Total parking (rounded up to nearest whole number) EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces -EVSE Installed (EVSE other may be "Capable," "Ready'' or "Installed.") Installed Total *Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation ;:: $60,000 or indude an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation ;:: $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. B D Nonresidential new construction (includes hotels/motels) □ Exception · Total Parking Spaces EVSE Spaces Proposed Capable I Ready I Installed l Total I I I Calculation: Refer to the table below: Total Number of Parking Spaces provided Number of required EV Soaces Number of reauired EVSE Installed Spaces □ 0-9 1 1 □ 10-25 2 1 □ 26-50 4 2 □ 51-75 6 3 □ 76-100 9 5 □ 101-150 12 6 □ 151-200 17 9 □ 201 and over 10 percent of total 50 oercent of Reau ired EV Spaces Updated 8/15/2019 5 City of Carlsbad Cl imate Action Plan Consistency Checklist 5. D Transportation Demand Management (TOM): Nonresidential ONLY An approved Transportation Demand Management (TDM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TDM plan. If TDM is applicable to your permit, staff will contact the applicant to develop a site-specific TDM plan based on the permit details. Acknowledgment: Employee ADT Estimation for Various Commercial Uses EmpADTfor first 1,000 s.f. EmpADTI 1000 s.f.1 Office (all)2 20 Restaurant 11 Retaib 8 Industrial 4 Manufacturing 4 Warehousin 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 10th Edition 13 11 4.5 3.5 3 1 2 For all office uses, use SAN DAG rate of 20 ADT/1 ,000 sf to calculate employee ADT 3 Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf = 8 ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. 8,334 sf / 1,000 x 4.5 + 8 = 46 Em lo ee ADT I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a TDM plan and understand that an approved TDM plan is a condition of permit issuance. Applicant Signature: __________________ _ Date: ______ _ Person other than Applicant to be contacted for TDM compliance (if applicable): Name (Printed): __________________ _ Phone Number: _____ _ Email Address: -------------------- Updated 8/ I 5/20 I 9 6 CARLSBAD CBR2019-2546 9/21/2019 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR2019-2546 JURISDICTION: CARLSBAD PROJECT ADDRESS: 2717 WILSON STREET FLOOR AREA: REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 9/21/2019 FOREWORD (PLEASE READ): STORIES: HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 9/17/2019 PLAN REVIEWER: Bert Domingo This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this 11st (or a copy) where each correction Item has been addressed, I.e., plan sheet number, specification section, etc. Be sure to enclose the marked up 11st when you submit the revised plans. CARLSBAD CBR2019-2546 9/21/2019 PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations. (California Business and Professions Code). STRUCTURAL 4. Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. Roof trusses to be a deferred submittal. Refer to sheet T-1 for notes 5. Please provide evidence that the engineer-of-record (or architect) has reviewed the truss calculation package prepared by others (i.e., a "review" stamp on the truss calculations or a letter). CBC Section 107.3.4.1. Roof trusses to be a deferred submittal. A truss review letter shall be provided when truss drawings and calculations are submitted to the City ELECTRICAL for review. Refer to sheet T-1 for notes 6. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If the service is over 200 amperes, submit a single line diagram, panel schedules, and provide service load calculations. A 200Amp panel shall be provided. refer to sheet 2.1 note #10 7. Note on the plans that receptacle outlet locations will comply with CEC Article 210.52. Note added. refer to sheet 2.3 "Power and Lighting Notes" #19 CARLSBAD CBR2019-2546 9/21/2019 8. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). b) Weather resistant type for receptacles installed in damp or wet locations (outside). c) Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(A): Kitchens, laundry areas, family, living, bedrooms, dining, halls, etc. d) GFCI protected outlets for locations described in NEC 210.8(A): Laundry areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors, within 6' of a sink, etc. Notes updated, refer to sheet A2.3 PLUMBING 9. Show water heater size (1 st hour rating), type, and location on plans. Note: For both new dwellings and additions the Energy Standards (150.0(n)) requires a gas input rating of 200,000 Btu for both tank and instantaneous gas water heaters. (Also) Provide a gas piping design for the gas system. Notes updated, refer to sheet A2.1 Keynote #5 + A4.0 building section #2 10. An instantaneous water heater is shown on the plans. Please Include a gas pipe sizing design (Isometric or pipe layout) for all gas loads. a) The gas pipe sizing for a tank type water heater shall be based upon a minimum 199,000 Btu gas input rating. Energy Standards 150.0(n). Gas Diagram added, refer to sheet A2.1 11. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8 GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 1.8 GPM of flow. CPC Sections 407,408,411,412. Notes updated, refer to sheet A-1 "Green Building Notes" 12. Specify on the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California SB407. Notes updated, refer to sheet T1 under "Project Scope" CARLSBAD CBR2019-2546 9/21/2019 MISCELLANEOUS 13. Title 24 calculations did not seem to have included the requirements of the new exterior walls. Calculations updated 14. Please show the recommended insulation for the roofs and the walls on the sections. Insulation notes updated. refer to sheet A-4 and sheet A 15. R3's: For the following types of projects, a minimum of one "EVSE (Electric Vehicle Supply Equipment) ready space" shall be installed: • New one-and two-family dwellings • Townhouse style with attached garages • Major residential renovations (defined as renovations/additions having a valuation of $60,000 or more) • Any project with an electrical service upgrade (including upgrades for PV installation) The "EVSE ready space" shall have the following: Panel capability, 40A 2 pole breaker, 1" raceway, No. 8 conductors installed to the anticipated charger location. EVSE outlet added refer to sheet A2.3 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes liil No □ 3-Car garage and entry tower added to scope of work The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bart Domingo at EsGil. Thank you.