HomeMy WebLinkAbout2717 WILSON ST; ; CBR2019-2546; PermitBuilding Permit Finaled
Residential Permit
Print Date: 04/23/2021
Job Address:
Permit Type:
Parcel#:
Valuation:
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition:
Sprinkled:
Project Title:
2717 WILSON ST, CARLSBAD, CA 92008-1530
BLDG-Residential Work Class:
1561302100 Track#:
$113,680.69 Lot#:
Project#:
Plan#:
Construction Type:
Orig. Plan Check#:
Plan Check#:
Alteration
(city of
Carlsbad
Permit No: CBR2019-2546
Status:
Applied:
Issued:
Finaled Close Out:
Inspector:
Final Inspection:
Closed -Fina led
09/13/2019
04/23/2020
TAlva
04/23/2021
Description: VEIGA: 1,925 SF REMODEL (RECONFIGURE EXISTING LIVING SPACE)// REMOVE FLAT ROOF AND REPLACE W/ PITCHED ROC
Applicant:
CARLOS ARCHITECTS INC
3327 ADAMS ST
CARLSBAD, CA 92008-2502
(760) 579-3996
FEE
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Property Owner:
PAHL ARCHIE W JR FAMILY
2717 WILSON ST
CARLSBAD, CA 92008
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
REFUND
561473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
Total Fees: $3,896.53 Total Payments To Date: $3,896.53 Balance Due:
AMOUNT
$675.70
$2,861.05
$66.00
$92.00
$182.00
$0.00
$5.00
$14.78
$0.00
Please take NOTICE that approval of your project includes the 11 lmposition" of fees1 dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction. '1 You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
{cicyof
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
PC Deposit ---------
Date _'9~-~J·3_,_-_._{q __
JobAddress___;'t-:c......::7c....::l_....,...;...__VJ__:_\L.:=--9<-0_~-'--.. ..:.......:.T' ___ suite: ___ APN: (!'(p -,_o · t.l -oo
CT/Project#:, _________________ Lot#:. ___ _
Fire Sprinklers: yes/€:) Air Conditioning: ~ no Electrical Panel Upgrade:@no
BRIEF DESCRIPTION OF WORK: I I '\2S" ~ Y1-e'M°'1~ "fl) 6)(.1-;,,"t ~G-'Z.'
□ Addition/New: _____ Living SF, ____ Deck SF, ____ Patio SF, ____ Garage SF
Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __
WRemodel: \ ,c.:r 2. r SF of affected area Is the area a conversion or change of use? YesE)
□ Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _
□ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground , Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No
Panel Upgrade: Yes/ No
D Reroof: _____________________________________ _
D Plumbing/Mechanical/Electrical Only: ________________________ _
D Other:------------------------------------
DESIGN PROFESSIONAL
Name: '-5/Jc ~ ('fU.O'!Nf
Address: ________________ _
City: _______ State: ___ .Zip: ___ _
Phone: _________________ _
Email:----------,=-~=,..,...,....,.,..._ ___ _
Architect State License: _,C"""_.,,,e:..,.ffle..=._.._ ... 'f-~----
CONTRACTOR BUSINESS
Name: ±~Q
Address: __________________ _
City: ________ State: ___ .Zip: ______ _
Phone: ___________________ _
Email: ___________________ _
State License: ______ Bus. License: ______ _
{Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law
{Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.S by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}).
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
B-1 Page 1 of 2 Rev. 06/18
( OPTION A): WORKERS'COMPENSATION DECLARATION:
I hearby affirm under penalty of perjury one of the following declarations:
□ I have and wilt maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued.
□ I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: Insurance Company Name: ______________________ _
Policy No. ______________ Expiration Date: _________ _
0 Certificate of Exemption: t certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage ls unlawful, and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
interest and attorney's fees.
CONTRACTOR SIGNATURE: □AGENT DATE: ----------------------------------
( OPTION B ): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's license Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work
himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 l, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's license Law).
0 I am exempt under Section ________ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 Yes O No
2. r (have/ have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/
contractors' license number):
5. I will provide some of the work, but I have contracted {hired) the following persons to provide the work indicated {include name/ address/ phone/ type of work):
OWNER SIGNATURE: ___________________ □AGENT DATE: _____ _
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name: ______________________ Lender's Address: _____________________ _
ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes O No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes O No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I Al50 AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE CITY OF CARl5BADAGAINST All LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CllY IN CONSEQUENCE OF
THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over S'O' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Co ire by limitation and become null and void if the building or work authorized
by such permit is not commenced within 180 days from the date of sue r the building o ork authorized by such permit is suspended or abandoned at anytime
after the work is commenced for a period of 180 days (Section 1 . Uniform Building Cod::·[::;.. ___ _
APPLICANT SIGNATURE:
1635 Faraday Ave Carlsbad, CA 92008
8-1
Ph: 760-602-2719 Fax: 760-602-8558
Page 2 of2
DATE: _1 ___ ~.L..1-'-~-.. __,__I_J't.__
Email: Building@carlsbadca.gov
Rev. 06/18
Permit Type: BLDG-Residential
Work Class: Alteration
Status:
Scheduled
Date
Closed -Finaled
Actual Inspection Type
Start Date
Checklist Item
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Friday, April 23, 2021
Application Date: 09/13/2019 Owner: TRUST PAHL ARCHIE W JR FAMILY
Issue Date: 04/23/2020 Subdivision: WILSONIA TRACT
Expiration Date: 09/13/2021
IVR Number: 21744
Addrnss: 2717 WILSON ST
CARLSBAD, CA 92008-1530
Inspection No.
COMMENTS
April 23, 2021:
Inspection
Status
Primary Inspector
1. No NSFD Final/building deficiencies.
2. Final structural, electrical, plumbing, and
mechanical work, per structural and
architectural plans and design
specifications-approved.
3. Verified final third-party special
for/deputy inspector reports-approved.
4. Waste management Final receipts,
documentation Verified and filed in city
records-Approved.
April 23, 2021:
1. No NSFD Final/building deficiencies.
2. Final structural, electrical, plumbing, and
mechanical work, per structural and
architectura I plans and design
specifications-approved.
3. Verified final third-party special
for/deputy inspector reports-approved.
4. Waste management Final receipts,
documentation Verified and filed in city
records-Approved.
April 23, 2021:
1. No NSFD Final/buildfng deficiencies.
2. Final structural, electrical, plumbing, and
mechanical work, per structural and
architectural plans and design
specifications-approved.
3. Verified final third-party special
for/deputy inspector reports-approved.
4. Waste management Final receipts,
documentation Verified and filed in city
records-Approved.
April 23, 2021:
1. No NSFD Final/building deficiencies.
2. Final structural, electrical, plumbing, and
mechanical work, per structural and
architectural plans and design
specifications-approved.
3. Verified final third-party special
for/deputy inspector reports-approved.
4. Waste management Final receipts,
documentation Verified and filed in city
records-Approved.
Reinspection Inspection
Passed
Yes
Yes
Yes
Yes
Page 18 of 18
Permit Type:
Work Class:
Status:
Scheduled
Date
BLDG-Residential
Alteration
Closed -Finaled
Actual Inspection Type
Start Date
BLDG-Structural Final
BLDG-Electrical Final
Friday, April 23, 2021
Application Date: 09/13/2019 Owrn?r: TRUST PAHL ARCHIE W JR FAMILY
Issue Date: 04/23/2020 Subdivision: WILSONIA TRACT
Expiration Date: 09/13/2021 Address: 2717 WILSON ST
IVR Number: 21744 CARLSBAD, CA 92008-1530
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
April 16, 2021
1. Building-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural scope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique, contractor
representative, waste management
documentation and mandatory energy
forms signatures required, and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
4. Final third-party special/deputy inspector
reports. and any structural observation
reports, or surveyor or civil engineering
final reports required at final inspection.
April 16, 2021:
1. Building-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural scope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique, contractor
representative, waste management
documentation and mandatory energy
forms signatures required, and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
No
No
Page 17 of 18
Permit Type: BLDG-Residential Application Date: 09/13/2019 Owner: TRUST PAHL ARCHIE W JR FAMILY
Work Class: Alteration Issue Date: 04/23/2020 Subdi;vision: WILSONIA TRACT
Status; Closed -Finaled Expiration Date: 09/13/2021 Addrnss: 2717 WILSON ST
IVR Number: 21744 CARLSBAD, CA 92008-1530
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
Friday, April 23, 2021
Status
COMMENTS
April 16, 2021:
1. Buildirg-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural scope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique, contractor
representative, waste management
documentation and mandatory energy
forms signatures required, and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
4. Final third-party special/deputy inspector
reports, and any structural observation
reports, or surveyor or civil engineering
final reports required at final inspection.
April 16, 2021:
1. Building-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural scope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique, contractor
representative, waste management
documentation and mandatory energy
forms signatures required, and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
April 16, 2021:
1. Building-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural scope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique, contractor
representative, waste management
documentation and mandatory energy
forms signatures required, and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
Passed
No
No
No
Pago 16 of 18
Permit Type: BLDG-Residential
Work Class: Alteration
Status:
Scheduled
Date
04/23/2021
Closed -Finaled
Actual Inspection Type
Start Date
BLDG-Structural Final
BLDG-Electrical Final
04/23/2021 BLDG-Final Inspection
Friday, April 23, 2021
Application Date: 09/13/2019 Owner: TRUST PAHL ARCHIE W JR FAMILY
Issue Date: 04/23/2020
Expiration Date: 09/13/2021
IVR Number: 21744
Subdivision: WILSONIA TRACT
Addrnss: 2717 WILSON ST
CARLSBAD, CA 92008-1530
Inspection No.
April 16, 2021:
Inspection
Status
Primary Inspector
1. Building-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural scope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique, contractor
representative, waste management
documentation and mandatory energy
forms signatures required, and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
4. Final third-party special/deputy inspector
reports, and any structural observation
reports, or surveyor or civil engineering
final reports required at final inspection.
April 16, 2021
1. Building-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural s~ope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique, contractor
representative, waste management
documentation and mandatory energy
forms signatures required, and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
155711-2021 Cancelled Tim Kersch
Reinspection Inspection
No
No
Relnspection Incomplete
Page 15 of 18
Permit Type: BLDG-Residential
Work Class: Alteration
Status: Closed -Finaled
Application Date: 09/13/2019 Own.,,: TRUST PAHL ARCHIE W JR FAMILY
Issue Date: 04/23/2020
Expiration Date: 09/13/2021
IVR Number: 21744
Subdivision: WILSONIA TRACT
Address: 2717 WILSON ST
CARLSBAD, CA 92008-1530
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reinspectlon Inspection
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
Friday, April 23, 2021
COMMENTS
April 16, 2021
1. Building-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural scope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique, contractor
representative, waste management
documentation and mandatory energy
forms signatures required, and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
4. Final third-party special/deputy inspector
reports, and any structural observation
reports, or surveyor or civil engineering
final reports required at final inspection.
April 16, 2021:
1. Building-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural scope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique, contractor
representative, waste management
documentation and mandatory energy
forms signatures required, and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
April 16, 2021:
1. Building-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural scope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique. contractor
representative, waste management
documentation and mandatory energy
forms signatures required, and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
Passed
No
No
No
Page 14 of 18
Permit Type: BLDG-Residential
Work Class: Alteration
Status:
Scheduled
Date
04/21/2021
Closed -Finaled
Actual Inspection Type
Start Date
BLDG-Structural Final
BLDG-Electrical Final
BLDG-Final Inspection
Friday, April 23, 2021
Application Date: 09/1312019 Owm,r: TRUST PAHL ARCHIE W JR FAMILY
Issue Date: 04/2312020 Subdivision: WILSONIA TRACT
Expiration Date: 0911312021
IVR Number: 21744
Address: 2717 WILSON ST
CARLSBAD, CA 92008-1530
Inspection No.
April 16, 2021:
Inspection
Status
Primary Inspector
1. Building-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural scope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique, contractor
representative, waste management
documentation and mandatory energy
forms signatures required, and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
4. Final third-party special/deputy inspector
reports. and any structural observation
reports, or surveyor or civil engineering
final reports required at final inspection.
April 16, 2021:
1. Building-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural scope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique, contractor
representative, waste management
documentation and mandatory energy
forms signatures required, and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
155592-2021 Cancelled Tim Kersch
Reinspection Inspection
No
No
Reinspection Incomplete
Page 13 of 18
Permit Type: BLDG-Residential
Work Class: Alteration
Status; Closed -Fina led
Application Date: 09/13/2019
Issue Date: 04/23/2020
Expiration Date: 09/13/2021
IVR Number: 21744
Owner: TRUST PAHL ARCHIE W JR FAMILY
Subdivision: WILSONIA TRACT
Addrnss: 2717 WILSON ST
CARLSBAD, CA 92008-1530
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Fina I
BLDG-Mechanical Final
Friday, April 23, 2021
COMMENTS
April 16, 2021:
1. Building-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural scope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique, contractor
representative, waste management
documentation and mandatory energy
forms signatures required, and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
4. Final third-party special/deputy inspector
reports, and any structural observation
reports, or surveyor or civil engineering
final reports required at final inspection.
April 16, 2021
1. Building-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural scope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique, contractor
representative, waste management
documentation and mandatory energy
forms signatures required. and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
April 16, 2021:
1. Building-new single-family dwelling
deficiencies.
2. Mechanical electrical plumbing and
structural scope of work per structural
plans and detail specifications -not ready.
3. Inform Enrique, contractor
representative, waste management
documentation and mandatory energy
forms signatures required, and all new
single family dwelling work per
architectural and structural plans need to
be completed prior final inspection.
Passed
No
No
No
Page 12 of 18
Permit Type: BLDG-Residential
Work Class: Alteration
Status: Closed -Finaled
Application Date: 09/13/2019 Owner: TRUST PAHL ARCHIE W JR FAMILY
Issue Date: 04/23/2020 Subdivision: WILSONIA TRACT
Expiration Date: 09/13/2021
IVR Number: 21744
Address: 2717 WILSON ST
CARLSBAD, CA 92008-1530
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
March 11, 2021: (virtual inspection).
***Building deficiencies***
1. Relocated existing electrical main
service panel to new garage area new
electrical Panel Upgrade requires:
a) grounding rods, with continuous electro
grounding conductor wire, not installed-not
approved.
b) Cold water grounding bond wire and
clamp, not installed.
c) New electrical ground wire, not landed
on bus bar, inside new electrical main
service panel.
d) no SDGE work order on site to be
verified for new location and height
requirements for new electrical main
service panel.
e) additional corrections may follow.
March 15, 2021:
No Building/panel upgrade deficiencies
1. Relocated existing electrical main
service panel to new garage area new
electrical Panel Upgrade requires:
a) grounding rods, with continuous electro
grounding conductor wire
installed-approved.
b) Cold water grounding bond wire and
clamp installed.
c) New electrical ground wire, landed on
bus bar, inside new 200 amp. electrical
main service panel.
d) SDGE work order on site and verified
for new location and height requirements
for new 200 amp. electrical main service
panel.
e) no additional corrections.
f) released new to 200 amp. panel upgrade
to SDGE.
04/16/2021 04116/2021 BLDG-Final Inspection 155115-2021 Failed Tony Alvarado
Friday, April 23, 2021
Passed
No
Yes
Reinspection Incomplete
Page 11 of 18
Permit Type: BLDG-Residential
Work Class: Alteration
Status:
Scheduled
Date
Closed -Finaled
Actual Inspection Type
Start Date
Checklist Item
Application Date: 09/13/2019 Owner: TRUST PAHL ARCHIE W JR FAMILY
Issue Date: 04/23/2020 Subdivision: WILSONIA TRACT
Expiration Date: 09/13/2021
IVR Number: 21744
Inspection No.
COMMENTS
Inspection
Status
Addrnss: 2717 WILSON ST
CARLSBAD, CA 92008-1530
Primary Inspector Reinspection Inspection
Passed
BLDG·Building Deficiency March 11, 2021: (virtual inspection).
•**Building deficiencies*""
No
03/15/2021 03/15/2021 BLDG-33 Service
Change/Upgrade
Friday, April 23, 2021
1. Relocated existing electrical main
service panel to new garage area new
electrical Panel Upgrade requires:
a) grounding rods, with continuous electro
grounding conductor wire, not installed•not
approved.
b) Cold water grounding bond wire and
clamp, not installed.
c) New electrical ground wire, not landed
on bus bar, inside new electrical main
service panel.
d) no SDGE work order on site to be
verified for new location and height
requirements for new electrical main
seivice panel.
e) additional corrections may follow.
152706-2021 Passed Tony Alvarado Complete
Page 10 of 18
Permit Type: BLDG-Residential
Work Class: Alteration
Status:
Scheduled
Date
Closed -Finaled
Actual Inspection Type
Start Date
Checklist Item
Application Date: 09/13/2019 Owner: TRUST PAHL ARCHIE W JR FAMILY
Issue Date: 04/23/2020 Subdivision: WILSONIA TRACT
Expiration Date: 09/13/2021
IVR Number:
Inspection No.
COMMENTS
21744
Inspection
Status
Address: 2717 WILSON ST
CARLSBAD, CA 92008-1530
Primary Inspector Reinspection Inspection
Passed
BLDG-Building Deficiency January 25, 2021: (virtual inspection).
"No pool deficiencies".
Yes
02/04/2021 02/04/2021 BLDG-16 lnsulatlon
Checklist Item
1. lnsulation/title-24 wall, ceilings and
perimeter foam insulation at all wall
penetration/openings, scope of
work-approved.
2. All rough framing combination minor
corrections addressed for the following:
a) missing plumbing
bracing/strapping-approved.
b) exterior wall sole plate-anchor bolts
missing at three locations-approved.
c) truss metal clip connectors missing in a
few locations, scope of work, scope of
rough combination work per
architectural/structural engineer's plan and
design specifications-approved.
149776-2021
COMMENTS
Passed Tony Alvarado
BLDG-Building Deficiency February 4, 2021: (virtual inspection).
"No Building deficiencies".
02/09/2021 02109/2021 BLDG~17 Interior
Lath/Drywall
Checklist Item
1. lnsulation/title-24 wall, ceilings and
perimeter foam insulation at all wall
penetration/openings, scope of
work-approved.
2. All rough framing combination minor
corrections addressed for the following:
a) missing plumbing
bracing/strapping-approved .
b) exterior wall sole plate-anchor bolts
missing at three locations-approved.
c) truss metal clip connectors missing in a
few locations, scope of work, scope of
rough combination work per
architectural/structural engineer's plan and
design specifications-approved.
150136-2021 Passed Tony Alvarado
COMMENTS
BLDG-Building Deficiency February 9, 2021: (virtual inspection).
03/11/2021 03/11/2021 BLDG-33 Service
Change/Upgrade
Friday, April 23, 2021
--------·---------------
1. Interior drywall type and drywall nailing
pattern, scope of work-approved.
152504-2021 Falled Tony Alvarado
Complete
Passed
Yes
Complete
Passed
Yes
Reinspection Incomplete
Page 9 of 18
Permit Type: BLDG-Residential
Work Class: Alteration
Application Date: 09/13/2019 Own,,r: TRUST PAHL ARCHIE W JR FAMILY
Status:
Scheduled
Date
12/16/2020
01/2812021
02/03/2021
Issue Date: 04/23/2020
Closed -Finaled Expiration Date: 09/13/2021
IVR Number: 21744
Subdivision: WILSONIA TRACT
Addrnss: 2717 WILSON ST
CARLSBAD, CA 92008-1530
Actua I Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency November 6, 2020: Partial roof sheathing Yes
nailing inspection.
1. Roof sheathing type/nailing pattern, roof
dwelling house area (only) -dry in due to
rain event -approved.
12/1612020 BLDG-14 146330-2020 Partial Pass Tony Alvarado Reinspection Incomplete
Frame/Steel/Bolling/We
ldlng (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency November 6, 2020: Partial roof sheathing Yes
nailing inspection.
1. Roof sheathing type/nailing pattern, roof
dwelling house area (only) -dry in due to
rain event -approved.
BLDG-Building Deficiency December 16th, 2020: Yes
1. Exterior shearwall nailing pattern not
correct, shearwall,nails missing, A-35
metal clips missing nails, missing A-35
hardware clips in some areas, (2) qty.
holddowns missing at existing wall, lower
level remodel rear house wall area.
2. Contractor Enrique will fix few areas
that need to be addressed, and next
inspection will be verifying redo shear
wall/hold downs work by virtual
inspection.
3. OK to continue stucco lath paper and
roof felt paper, to dry-in structure.
01/28/2021 BLOG-84 Rough 149342-2021 Partial Pass Tony Alvarado Re inspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
02/03/2021 BLDG-16 Insulation 149773-2021 Passed Tony Alvarado Complete
Friday, April 23, 2021 Page 8 of 18
Permit Type: BLDG-Residential
Work Class: Alteration
Status: Closed -Finaled
Application Date: 09/13/2019 Owner: TRUST PAHL ARCHIE W JR FAMILY
Issue Date: 04/23/2020 Subdivision: WILSONIA TRACT
Expiration Date: 09/13/2021
IVR Number: 21744
Address: 2717 WILSON ST
CARLSBAD, CA 92008-1530
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
10/27/2020
11/06/2020
BLDG-Building Deficiency October 9, 2020:
1. Rear elevation patio footings and slab
steel reinforcement, per engineered plans,
details and specifications-approved.
2. Verified deputy inspectors report for
Dowling into existing slab -approved.
10/27/2020 BLDG-11 141925-2020 Passed Tony Alvarado
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
October 27th, 2020:
1. Footings steel reinforcement rebar,
attached open lattice patio structure, per
structural engineer plans and detail
specifications-approved .
September 24, 2020: (Failed).
Spoke to project superintendent Enrique -
Certification required prior to concrete pour
are still not provided at time of footing slab
inspection.
Informed and discussed with geotechnical
engineer second time, to verify city
requirements prior to footing/slab Final
inspection sign-offs.
Scope of work for foundation/slab footing
reinforcement steel work -pending
approval items:
1. height certification form required-per a
civil engineer/surveyor, (prior to concrete
pour).
2. Property line setbacks to proposed
footing/foundation forms for new garage
structure-per a civil engineer/surveyor,
(Prior to concrete pour).
3. Pad certification per soils engineer foI
footing Bottoms and slab/foundation , (Prior
to concrete pour).
11/06/2020 BLDG-14 143139-2020 Partial Pass Tony Alvarado
Frame/Steel/Bolting/We
!ding (Decks)
Checklist Item
BLDG-Building Deficiency
COMMENTS
November 6, 2020: Partial roof sheathing
nailing inspection.
1. Roof sheathing type/nailing pattern, roof
dwelling house area (only) -dry in due to
rain event-approved.
BLDG-15 Roof/ReRoof
(Patio)
143138-2020 Partial Pass Tony Alvarado
Friday, April 23, 2021
-------···---···-----·
Yes
Complete
Passed
Yes
No
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Page 7 of 18
Permit Type: BLDG-Residential
Work Class: Alteration
Status: Closed -Finaled
Application Date: 09/13/2019 Own1>r: TRUST PAHL ARCHIE W JR FAMILY
Issue Date: 04/23/2020 Subdivision: WILSONIA TRACT
Expiration Date: 09/13/2021
IVR Number: 21744
Address: 2717 WILSON ST
CARLSBAD, CA 92008-1530
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
Friday, April 23, 2021
COMMENTS
September 18, 2020:
Scope of work for foundation/slab footing
reinforcement steel work -pending
approval items:
1. height certification form required-per a
civil engineer/surveyor, (prior to concrete
pour).
2. Property line setbacks to proposed
footing/foundation forms for new garage
structure-per a civil engineer/surveyor,
(Prior to concrete pour).
3. Pad certification per soils engineer for
footing Bottoms and slab/foundation , (Prior
to concrete pour).
September 21, 2020: (Failed).
Scope of work for foundation/slab footing
reinforcement steel work -pending
approval items:
1. height certification form required-per a
civil engineer/surveyor, (prior to concrete
pour).
2. Property line setbacks to proposed
footing/foundation forms for new garage
structure-per a civil engineer/surveyor,
(Prior to concrete pour).
3. Pad certification per soils engineer for
footing Bottoms and slab/foundation , (Prior
to concrete pour).
September 24, 2020: (Failed).
Spoke to project superintendent Enrique -
Certification required prior to concrete pour
are still not provided at time of footing slab
inspection.
Informed and discussed with geotechnical
engineer second time, to verify city
requirements prior to footing/slab Final
inspection sign-offs.
Scope of work for foundation/slab footing
reinforcement steel work -pending
approval items:
1. height certification form required-per a
civil engineer/surveyor, (prior to concrete
pour).
2. Property line setbacks to proposed
footing/foundation forms for new garage
structure-per a civil engineer/surveyor,
(Prior to concrete pour).
3. Pad certification per soils engineer for
footing Bottoms and slab/foundation , (Prior
to concrete pour).
Passed
Yes
No
No
Page 6 of 18
Permit Type: BLDG-Residential
Work Class: Alteration
Status: Closed -Finaled
Scheduled Actual Inspection Type
Date Start Date
10/0912020 10109/2020 BLDG-11
Friday, April 23, 2021
Foundatlon/Ftg/Plers
(Rebar)
Application Date: 09/13/2019 Own<,r: TRUST PAHL ARCHIE W JR FAMILY
lssu~ Date: 04/23/2020 Subdivision: WILSONIA TRACT
Expiration Date: 09/13/2021 Address: 2717 WILSON ST
CARLSBAD, CA 92008-1530 IVR Number: 21744
Inspection No. Inspection Primary Inspector Reinspection Inspection
Status
140565-2020 Partlal Pass Tony Alvarado Relnspection Incomplete
Page 5 of 18
='r:;"-!!Jz3: -l· *d * ~""'-~~t." -z~ ~.::; r~ * "~,: 1 * %~;£~-:?£;;,½! ~ ~
·: .· ., . BE.RMiltlNSPECTION'IUATOR:V fq1;~ft. II ~9::J~j . 50''' ·. ~·
Permit Type: BLDG-Residential
Work Class: Alteration
Status: Closed -Finaled
Application Date: 09/13/2019 Owm,r: TRUST PAHL ARCHIE W JR FAMILY
Issue Date: 04/23/2020
Expiration Date: 09/13/2021
IVR Number: 21744
Subdivision: WILSONIA TRACT
Address: 2717 WILSON ST
CARLSBAD, CA 92008-1530
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
Friday, April 23, 2021
BLDG-11 140248-2020 Cancelled Tony Alvarado
F ou n datlo n/Ftg/Plers
(Robar)
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
September 21, 2020: (Failed).
Scope of work for foundation/slab footing
reinforcement steel work -pending
approval items:
1. height certification form required-per a
civil engineer/surveyor, (prior to concrete
pour).
2. Property line setbacks to proposed
footing/foundation forms for new garage
structure-per a civil engineer/surveyor,
(Prior to concrete pour).
3. Pad certification per soils engineer for
footing Bottoms and slab/foundation , (Prior
to concrete pour).
September 24, 2020: (Failed).
Spoke to project superintendent Enrique -
Certification required prior to concrete pour
are still not provided at time of footing slab
inspection.
Informed and discussed with geotechnical
engineer second time, to verify city
requirements prior to footing/slab Final
inspection sign-offs.
Scope of work for foundation/slab footing
reinforcement steel work -pending
approval items:
1. height certification form required-per a
civil engineer/surveyor, (prior to concrete
pour).
2. Property line setbacks to proposed
footing/foundation forms for new garage
structure-per a civil engineer/surveyor,
(Prior to concrete pour).
3. Pad certification per soils engineer for
footing Bottoms and slab/foundation , (Prior
to concrete pour).
September 18, 2020:
Scope of work for foundation/slab footing
reinforcement steel work -pending
approval items:
1. height certification form required~ per a
civil engineerfsurveyor, (prior to concrete
pour).
2. Property line setbacks to proposed
footing/foundation forms for new garage
structure-per a civil engineer/surveyor,
(Prior to concrete pour).
3. Pad certification per soils engineer for
footing Bottoms and slab/foundation , (Prior
to concrete pour).
Reinspectlon Incomplete
Passed
No
No
Yes
Page 4 of 18
~--* * --,;_-•<-* %:;,, -Vfik=.:,,S. -,⇒=,-/{; = y 0 ">0 * "~ ct=~0 00=0 --~ ~~r '. ' Jgaifmtitlse~attl Rl&T:M' ~tfilli('~fiills'f ! ,,,,,", ~r:i:
Permit Type: BLDG-Residential
Work Class: Alteration
Status; Closed -Finaled
Application Date: 09/13/2019
Issue Date: 04/23/2020
Expiration Date: 09/13/2021
IVR Number: 21744
Own<>r: TRUST PAHL ARCHIE W JR FAMILY
Subdivision: WILSONIA TRACT
Addr,ess: 2717 WILSON ST
CARLSBAD, CA 92008-1530
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reins·pection Inspection
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
10/07/2020 10/07/2020
Friday, April 23, 2021
COMMENTS
September 18, 2020:
Scope of work for foundation/slab footing
reinforcement steel work -pending
approval items:
1. height certification form required-per a
civil engineer/surveyor, (prior to concrete
pour).
2. Property line setbacks to proposed
footing/foundation forms for new garage
structure-per a civil engineer/surveyor,
(Prior to concrete pour).
3. Pad certification per soils engineer for
footing Bottoms and slab/foundation, (Prior
to concrete pour).
September 24, 2020: (Failed).
Spoke to project superintendent Enrique -
Certification required prior to concrete pour
are still not provided at time of footing slab
inspection.
Informed and discussed with geotechnical
engineer second time, to verify city
requirements prior to footing/slab Final
inspection sign-offs.
Scope of work for foundation/slab footing
reinforcement steel work-pending
approval items;
1. height certification form required-per a
civil engineer/surveyor, (prior to concrete
pour).
2. Property line setbacks to proposed
footing/foundation forms for new garage
structure-per a civil engineer/surveyor,
(Prior to concrete pour).
3. Pad certification per soils engineer for
footing Bottoms and slab/foundation , (Prior
to concrete pour).
September 21, 2020: (Failed).
Scope of work for foundation/slab footing
reinforcement steel work -pending
approval items:
1. height certification form required-per a
civil engineer/surveyor, (prior to concrete
pour).
2. Property line setbacks to proposed
footing/foundation forms for new garage
structure-per a civil engineer/surveyor,
(Prior to concrete pour).
3. Pad certification per soils engineer for
footing Bottoms and slab/foundation , (Prior
to concrete pour).
Passed
Yes
No
No
Page 3 of 18
Permit Type: BLDG-Residential
Work Class: Alteration
Status: Closed -Finaled
Application Date: 09/13/2019 Owne•r: TRUST PAHL ARCHIE W JR FAMILY
Issue Date: 04/23/2020
Expiration Date: 09/13/2021
IVR Number: 21744
Subdivision: WILSONIA TRACT
Addmss: 2717 WILSON ST
CARLSBAD, CA 92008-1530.
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
September 21, 2020: (Failed).
Scope of work for foundation/slab footing
reinforcement steel work -pending
approval items:
1. height certification form required-per a
civil engineer/surveyor, (prior to concrete
pour).
2. Property line setbacks to proposed
footing/foundation forms for new garage
structure-per a civil engineer/surveyor,
(Prior to concrete pour).
3. Pad certification per soils engineer for
footing Bottoms and slab/foundation, (Prior
to concrete pour).
September 18, 2020:
Scope of work for foundation/slab footing
reinforcement steel work -pending
approval items:
1. height certification form required-per a
civil engineer/surveyor, (prior to concrete
pour).
2. Property line setbacks to proposed
footing/foundation forms for new garage
structure-per a civil engineer/surveyor,
(Prior to concrete pour).
3. Pad certification per soils engineer for
footing Bottoms and slab/foundation , (Prior
to concrete pour).
09/24/2020 09/24/2020 BLDG-11
Foundatlon/Ftg/Plers
(Rebar)
139167-2020 Failed Tony Alvarado
Friday, April 23, 2021
Passed
No
Yes
Reinspectlon Incomplete
Page 2 of 18
Building Permit Inspection History Finaled
(city of
Carlsbad
Permit Type:
Work Class:
Status:
Scheduled
Date
08127/2020
09/10/2020
09/18/2020
09/21/2020
BLDG-Residential
Alteration
Closed -Finaled
Actual Inspection Type
Start Date
08127/2020 BLOG-SW-Pre-Con
Checklist Item
Application Date:
Issue Date:
Expiration Date:
IVR Number:
Inspection No.
136920-2020
COMMENTS
09/13/2019
04/23/2020
09/13/2021
21744
Inspection
Status
Owrwr: TRUST PAHL ARCHIE W JR FAMILY
Subdivision: WILSONIA TRACT
Address: 2717 WILSON ST
CARLSBAD, CA 92008-1530
Primary Inspector Reinspection Inspection
Partial Pass Tony Alvarado Relnspectlon Incomplete
Passed
BLDG•Building Deficiency August 27, 2020: Yes
09/10/2020 BLDG-21
Underground/Underflo
or Plumbing
Checklist Item
1. Preconstruction meeting for SWPPS,
BMPs and all erosion control measures in
place and intact at all times of construction.
Spoke to contractor Enrique and informed
regarding stormwater control measures.
2. Discussed with owner/builder and
contractor Henrique regarding letter
architect stating removal of most exterior
load bearing walls, except for two walls at
rear elevation bedroom area.
137660-2020 Passed Tony Alvarado
COMMENTS
BLDG-Building Deficiency September 1 0, 2020:
09/18/2020 BLOG-11
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item
1. Underground waste plumbing lines
under test,-approved.
136697-2020 Partial Pass Tony Alvarado
COMMENTS
BLDG-Building Deficiency September 18, 2020:
09/21/2020 BLOG-11
Foundation/Fig/Piers
(Rebar)
Scope of work. for foundation/slab footing
reinforcement steel work. -pending
approval items:
1. height certification form required-per a
civil engineer/surveyor, (prior to concrete
pour).
2. Property line setbacks to proposed
footing/foundation forms for new garage
structure-per a civil engineer/surveyor,
(Prior to concrete pour).
3. Pad certification per soils engineer for
footing Bottoms and slab/foundation , (Prior
to concrete pour).
138777-2020 Failed Tony Alvarado
Complete
Passed
Yes
Relnspection Incomplete
Passed
Yes
Reinspection Incomplete
Friday, April 23, 2021 Page 1 of 18
✓• EsG1I
A SA.f.Ebuilt'Ccm--,p,>ny
DATE: April 21, 2020
JURISDICTION: CARLSBAD
PLAN CHECK#.: CBR2019-2546 SET: III
PROJECT ADDRESS: 2717 WILSON STREET
PROJECT NAME: SFD REMODEL FOR VEIGA
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone#:
Date contacted: t.{ p_,/ }){) (by[,n) Email:
Mail Telephone Fax In Person
~ REMARKS: Set Ill partial submittal included only sheets 5-2.1 and 5-4.0. These were slip
sheeted onto set II received on 2/21.
By: Abe Doliente (for BD)
EsGil
4/14/20
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
•.
DATE: 3/10/2020
JURISDICTION: CARLSBAD
PLAN CHECK#.: CBR2019-2546
✓• EsG1I
A SAFEbuHfCompany
SET: II
PROJECT ADDRESS: 2717 WILSON STREET
PROJECT NAME: SFD REMODEL FOR VEIGA
□LICANT
/JuRis.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
L8] The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
L8] The applicant's copy of the check list has been sent to:
ANDREW CARLOS
D EsGil staff did not advise the applicant that the plan check has been completed.
L8] EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: ANDREW Telephone#: 760 579 3996
Date contacted: .31Jojao (bydc)) Email: INFO@ANDREWCARLOSARCHITECT.COM
Mail Telephone
0 REMARKS:
By: Bert Domingo
EsGil
Fax In Person
Enclosures:
2/21/2020
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
CARLSBAD CBR2019-2546
3/10/2020
NOTE: The items listed below are from the previous correction list. These
remaining items have not been adequately addressed. The numbers of the items
are from the previous check list and may not necessarily be in sequence. The
notes in bold font are current.
PLANS
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil is complete.
2. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
3. Plans deviating from conventional wood frame construction shall have the
structural portions signed and sealed by the California state licensed engineer or
architect responsible for their preparation, along with structural calculations.
(California Business and Professions Code).
PLUMBING
9. Show water heater size (1 st hour rating), type, and location on plans. Note: For
both new dwellings and additions the Energy Standards (150.0(n)) requires a gas
input rating of 200,000 Btu for both tank and instantaneous gas water heaters.
(Also) Provide a gas piping design for the gas system. Please show the
size of the pipes for each outlet. Also, please show the distance from the
meter for each outlet.
An instantaneous water heater is shown on the plans. Please include a gas
pipe sizing design (isometric or pipe layout) for all gas loads.
10. The gas pipe sizing for a tank type water heater shall be based upon a minimum
199,000 Btu gas input rating. Energy Standards 150.0(n).
CARLSBAD CBR2019-2546
3/10/2020
MISCELLANEOUS
13. Title 24 calculations did not seem to have included the requirements of the new
exterior walls. It seems not submitted with this package.
14. Please show the recommended insulation for the roofs and the walls on the
sections. This will be checked when item 13 is met.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes □ No □
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Bert Domingo at EsGil. Thank you.
DATE: 9/21/2019
JURISDICTION: CARLSBAD
PLAN CHECK#.: CBR2019-2546
✓• EsG1I
A '.)Af-Ebwlt Compan/
SET: I
PROJECT ADDRESS: 2717 WILSON STREET
PROJECT NAME: SFD REMODEL FOR VEIGA
□ APPLICANT
□ JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
ANDREW CARLOS
D EsGil staff did not advise the applicant that the plan check has been completed.
~ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: ANDREW
Date contacted".'~ i cj (bY1 G,) Email:
/ t_ Mail Telephone' ~x In Person
Telephone#: 760 579 3996
INFO@ANDREWCARLOSARCHITECTS.COM
CJ REMARKS: 1
By: Bert Domingo
EsGil
Enclosures:
9/17/2019
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) :560-1468 ♦ Fax (858) 560-1576
CARLSBAD CBR2019-2546
9/21/2019
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: CBR2019-2546 JURISDICTION: CARLSBAD
PROJECT ADDRESS: 2717 WILSON STREET
FLOOR AREA:
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 9/21/2019
FOREWORD (PLEASE READ):
STORIES:
HEIGHT:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 9/17/2019
PLAN REVIEWER: Bert Domingo
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC,
2015 UPC, 2015 UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
CARLSBAD CBR2019-2546
9/21/2019
PLANS
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil is complete.
2. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
3. Plans deviating from conventional wood frame construction shall have the
structural portions signed and sealed by the California state licensed engineer or
architect responsible for their preparation, along with structural calculations.
(California Business and Professions Code).
STRUCTURAL
4. Provide truss details and truss calculations for this project. Specify truss
identification numbers on the plans.
5. Please provide evidence that the engineer-of-record (or architect) has reviewed
the truss calculation package prepared by others (i.e., a "review" stamp on the
truss calculations or a letter). CBC Section 107 .3.4.1.
ELECTRICAL
6. Show on the plan the amperage of the electrical service, the location of the
service panel and the location of any sub-panels. If the service is over 200
amperes, submit a single line diagram, panel schedules, and provide service
load calculations.
7. Note on the plans that receptacle outlet locations will comply with CEC Article
210.52.
CARLSBAD CBR2019-2546
9/21/2019
8. Include on the plans the following specifications for electrical devices installed in
dwellings: CEC Article 210 & 406
a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all
receptacles in a dwelling).
b) Weather resistant type for receptacles installed in damp or wet locations
(outside).
c) Arc-fault protection for all outlets (not just receptacles) located in rooms
described in NEC 210.12(A): Kitchens, laundry areas, family, living,
bedrooms, dining, halls, etc.
d) GFCI protected outlets for locations described in NEC 210.8(A): Laundry
areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors,
within 6' of a sink, etc.
PLUMBING
9. Show water heater size (1 st hour rating), type, and location on plans. Note: For
both new dwellings and additions the Energy Standards (150.0(n)) requires a gas
input rating of 200,000 Btu for both tank and instantaneous gas water heaters.
(Also) Provide a gas piping design for the gas system.
10. An instantaneous water heater is shown on the plans. Please include a gas
pipe sizing design (isometric or pipe layout) for all gas loads.
a) The gas pipe sizing for a tank type water heater shall be based upon a
minimum 199,000 Btu gas input rating. Energy Standards 150.0(n).
11. Specify on the plans: Water conserving fixtures: New water closets shall use no
more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8
GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 1.8
GPM of flow. CPC Sections 407, 408, 411, 412.
12. Specify on the plans whether the existing house was built before or after 1994.
For additions or improvements to a residence built before 1994, note on the
plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons
of water per flush, urinals that use more than one gallon of water per flush,
showerheads that have a flow capacity of more than 2.5 gallons of water per
minute, and interior faucets that emit more than 2.2 gallons of water per minute)
shall be replaced. Certification of compliance shall be given to the building
inspector prior to final permit approval. California SB407.
CARLSBAD CBR2019-2546
9/21/2019
MISCELLANEOUS
13. Title 24 calculations did not seem to have included the requirements of the new
exterior walls.
14. Please show the recommended insulation for the roofs and the walls on the
sections.
15. R3's:
For the following types of projects, a minimum of one "EVSE (Electric Vehicle Supply
Equipment) ready space" shall be installed:
• New one-and two-family dwellings
• Townhouse style with attached garages
• Major residential renovations (defined as renovations/additions having a
valuation of $60,000 or more)
• Any project with an electrical service upgrade (including upgrades for PV
installation)
The "EVSE ready space" shall have the following: Panel capability, 40A 2 pole breaker,
1" raceway, No. 8 conductors installed to the anticipated charger location.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes □ No □
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Bert Domingo at EsGil. Thank you.
CARLSBAD CBR2019-2546
9/21/2019
/DO NOT PAY-THIS IS NOT AN INVOICE/
VALUATION AND PLAN CHECK FEE
JURISDICTION: CARLSBAD
PREPARED BY: Bert Domingo
BUILDING ADDRESS: 2717 WILSON STREET
BUILDING OCCUPANCY: R 3
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
CTY ESTIMATE
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code CB By Ordinance
1997 USC Building Permit Fee
1997 UBC Plan Check Fee
Type of Review:
D Repetitive Fee
• Repeats
0 Complete Review
D Other
D Hourly
EsGII F••
PLAN CHECK#.: CBR2019-2546
DATE: 9/21/2019
Reg . VALUE ($)
Mod.
113,284
113,284
D Structural Only
$439.241
Comments: In. addition to the above fee, an additional fee of$ is due ( hour@
$ /hr.) for the CalGreen review.
Sheet 1 of 1
□
«~~ ~ C ITY OF
CARLSBAD
PLANNING DIVISION
BUILDING PLAN CHECK
REVIEW CHECKLIST
P-28
DATE: 9/30/19 PROJECT NAME: ROOF/REMODEL
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.Qov
PROJECT ID:
PLAN CHECK NO: CBR2019-2546 SET#: 1 ADDRESS: 2717 WILSON APN: 156-130-21-00
T~i~ ~Ian check review is complete and has been AP~n OVE · by he rJ.ANNING
D1v1s1on.
FEB 2 0 2020 By: ALYSSA BARMAN
Cl )
A Final Inspection by the PLANNING Division is requ·re(f ,CJ Yes , ~ No l
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
This plan check review is NOT COMPLETE. Items missing or--incorrect are listed on
I the attached checklist. Please resubmit amended plans as required.
FEB 2 0 2020
Plan Check Comments have been sent to:
I NFO@ANDREWCARLOSARCH ITECTS.COM en r u -l, • ... • ...., .. o
BUil D'I ~ ~1 c::ic f\J
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING ENGINEERING FIRE PREVENTION
76o-602-4610 760-602-2750 760-602-4665
~ Alyssa Barman
760-602-2709
Alyssa. Bi;!rman~ca rlsbadca. gov
Remarks: 1,925 SF REMODEL TO EXTING DWELLING. REROOFING AND
PATIO COVERS.
REVIEW#:
1 2 3
1:8:1 □ □
1:8:1 □ □
1:8:1 □ □
1:8:1 □ □
1:8:1 □ □
Plan Check No. CBC2019-2546 Address 2717 WILSON ST Date 9/30/19 Review # 1
Planner ALYSSA BARMAN Phone (760) 602-2709
APN: 156-130-21-00
Type of Project & Use: ROOF/REMODEL Net Project Density: DU/AC
Zoning: R-1 General Plan: R-4 Facilities Management Zone: 1
CFD (in/out) #_Date of participation: __ Remaining net dev acres: __
(For non-residential development: Type of land use created by this permit: __ )
Legend: cgJ Item Complete D Item Incomplete -Needs your action
Environmental Review Required: YES □ NO □ TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES □ NO □ TYPE
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval: __
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES D NO 18:t
CA Coastal Commission Authority? YES D NOD
If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive,
Suite 103, San Diego, CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Habitat Management Plan
Data Entry Completed? YES □ NO □
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application
and assess fees in Energov
lnclusionary Housing Fee required: YES D NO D
(Effective date of lnclusionary Housing Ordinance -May 21, 1993.)
Data Entry Completed? YES □ NO □
For construction of inclusionary units, email notification provided to HNS?: YES D NO D
(Email Susan Steinkemp in HNS with project number and contact info)
1:8:] D D Housing Tracking Form (form P-20) completed: YES D NO D N/A D
P-28 Page 2 of 4 07/11
Site Plan:
181 □ □
181 □ □
181 □ □
181 □ □
181 □ □
□□□
181 □ □
□□□
□□□
P-28
Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines,
easements, existing and proposed structures, streets, existing street improvements, right-of-
way width, dimensional setbacks and existing topographical lines (including all side and rear
yard slopes). Provide legal description of property and assessor's parcel number.
City Council Policy 44 -Neighborhood Architectural Design Guidelines
1. Applicability: YES O NO 0
2. Project complies: YES D NOD
Zoning:
1. Setbacks:
Front:
Interior Side:
Street Side:
Rear:
Top of slope:
Required __ Shown
Required Shown
Required __ Shown
Required Shown
Required __ Shown __
2. Accessory structure setbacks:
Front: Required __ Shown __
Interior Side: Required __ Shown
Street Side: Required __ Shown __
Rear: Required __ Shown
Structure separation: Required __ Shown __
3. Lot Coverage: Required 40% Shown
PLEASE UPDATE PLANS TO SHOW LOT COVERAGE CALCULATION. LOT COVERAGE IS
TO BE CALCULATED AS THE TOTAL SQUARE FOOTAGE OF THE FOOTPRINT OF
STRUCTURES (I.E. THE EXISTING RESIDENCE, GARAGE, ACCESSORY DWELLING UNIT,
PROPOSED PATIO COVERS, AND EEXISTING STORAGE) DIVIDED BY THE TOTAL LOT
SIZE.
Lot coverage calculation updated on Sheet T-1
4. Height: Required __ Shown
5. Parking: Spaces Required __ Shown
(breakdown by uses for commercial and industrial projects required)
IN ORDER TO SHOW COMPLIANCE WITH THE CLIMATE ACTION PLAN CONSISTENCY
CHECKLIST, PLEASE SHOW WHERE EVSE READY PARKING SPACE IS TO BE LOCATED.
PLEASE FIND THE ELECTRIC VEHICLE ORDINANCE HERE:
https://www.carlsbadca.gov/services/depts/pw/environment/cap/ordinances.asp
EVSE receptical has been added to the garage -Sheet A2.3
Residential Guest Spaces Required __ Shown __
Additional Comments:
Page 3 of 4 07/11
1. PLEASE PROVIDE RESIDENTIAL BUILDING RECORD OR COPY OF APPROVED
PLANS/PERMITS FOR EXISTING TWO CAR GARAGE AT THE REAR OF THE
PROPERTY AND EXISTING ACCESSORY DWELLING UNIT. OR IF
UNPERMITTED, PLEASE SEE THE BUILDING DEPARTMENT FOR BUILDING
APPLICATIONS. The county building record does not show any permits for the existing ADU and 2-Car
Garage and Storage buildings. These structures will be removed (see A 1.1) and a new 3-car garage will
be constructed to meet parking requirements. See A 1.1 and Floor plan A2. 1.
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE
P-28 Page 4 of 4 07111
✓• EsG1I
DATE: 9/21/2019
JURISDICTION: CARLSBAD
PLAN CHECK#.: CBR2019-2546
PROJECT ADDRESS: 2717 WILSON STREET
PROJECT NAME: SFD REMODEL FOR VEIGA
SET: I
D APPLICANT
D JURIS.
R r-,_. F= ' i D
FEB 2 0 2020
D The plans transmitted herewith have been corrected where n~tessary and sub t Rtially comply
with the jurisdiction's codes. Lu .i : , ' ' 1
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at Es Gil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person .
~ The applicant's copy of the check list has been sent to:
ANDREW CARLOS
D Es Gil staff did not advise the applicant that the plan check has been completed .
~ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted : ANDREW Telephone#: 760 579 3996
Date contacted: (by: ) Email: INFO@ANDREWCARLOSARCHITECTS.COM
Mail Telephone
0 REMARKS:
By: Bert Domingo
EsGil
Fax In Person
Enclosures:
9/17/2019
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
J
C cifyof
Carlsbad
PURPOSE
CLIMATE ACTION PLAN
CONSISTENCY CHECKLIST
8-50
Development Services
Building Division
1635 Faraday Avenue
(760) 602-2719
www.carlsbadca.gov
This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance
requirements apply to their projects. The completed checklist must be included in the build ing permit application. It may be
necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate
full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach
to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as
specified by the ordinances.
NOTE: The following type of permits are not required to fill out this form
❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool
A If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance,
an explanation must be provided to the satisfaction of the Building Official.
A Details on CAP ordinance requirements are available on the city's website.
A A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be
completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and
download the latest form.
Project Name/Building
Permit No.:
Property Address/APN:
Applicant Name/Co.:
Applicant Address:
Contact Phone:
_V_E"_l_~_A-_vl_~_, ~_(:_.c.,u_C._~--BP No.: C6~a~ R :}__~<-/lo
I S"c, I !,O -Z. \ o o
Z 7 l 7 IN\L c;o,u -e.:r:
~ ,.. sr.::r 2,_ -7 ! s1 Contact Email:
Contact information of person completing this checklist (if different than above):
Name:
Company
name/address:
AN'-D~ ~L.uscontactPhone:
~kVLL0~ ,ArtCH-l'tt.:C(~ntactEmail: ,~?<?_Qvtd.V.P~cCjvlo ~
QV'C.1A11-a:..+-, Co~
Applicant Signature: -_.,;;;;;;;;;;;;;;;;;;;;; ... iiiiiiiiii~Ci=:::::~~~----Date:
B-50 Page 1 of 6 Revised 08/19
City of Carlsbad Climate Action Plan Consistency Checklist
Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project.
For alterations and additions to existing buildings, attach Building Permit Valuation worksheet.
Building Permit Valuation (BPV) from worksheet: $ J , cl]). Su 3 • 7-S ,-
~esidential
□ New construction
~ Additions and alterations:
□ BPV < $60,000
□ BPV ~ $60,000
□ Electrical service panel upgrade only
~ BPV ~ $200,000
D Nonresidential
□ New construction
□ Alterations:
□ BPV ~ $200,000 or additions~ 1,000
square feet
□ BPV ~ $1 ,000,000
□ ~ 2,000 sq. ft. new roof addition
1. Energy Efficiency
A high-rise residential building is 4 or more stories, including a
Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor
area is residential use
2A, 3A, 18, 28,
4A 38,4A
N/A N/A All residential additions and alterations
1A, 4A 4A 1-2 family dwellings and townhouses with attached garages
only
*Multi-family dwellings only where interior finishes are removed
1A, 4A* 18, 4A* and significant site work and upgrades to structural and
mechanical, electrical, and/or plumbing systems are proposed
1 B, 28, 38, 48 and 5
18, 5
18,28,5 Building alterations of~ 75% existing gross floor area
28, 5 1 B also applies if BPV ~ $200,000
Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for
more information when completing this section.
A )Qr Residential addition or alteration ?; $60,000 building permit valuation.
/' See CMC section 18.30.190.
Year Built Single-family Requirements
)(' Before 1978 Select one:
Kl"Duct sealinq ~tic insulation ' (:ool roof
D 1978 and later Select one:
D Lighting package D Water heating Package
D Between 1978 and 1991
□ 1992 and later
D N/A _________ _
D Exception: Home energy score <! 7
(attach certification)
Multi-family Requirements
D Attic insulation
Select one:
D Duct sealinq D Attic insulation D Cool roof
Select one:
D Lighting package D Water heating package
B. D Nonresidential* new construction or alterations?; $200,000 building permit valuation,
or additions ?; 1,000 square feet □ N/A
Updated 8/ I 5/20 19
L
2
City of Carlsbad Climate Action Plan Consistency Checklist
See CMC 18.21.155 and CALGreen Appendix AS, Division AS.2-Energy Efficiency.
A5.203.1.1 Choose one: D .1 Outdoor lighting D .2 Warehouse dock seal doors
D .3 Restaurant seNice water heating (comply with California Energy Code section 140.5, as amended) D N/A. _________ _
D .4 Daylight design PAFs D .5 Exhaust air heat recovery
A5.203.1.2.1
Choose one as applicable: D .95 Energy budget D .90 Energy budget D N/A
A5.211.1 ..
D On-s~e renewable energy D N/A
A5.21 1.3**
D Green power (if offered by local utility provider, 50% minimum renewable sources) D N/A
A5.212.1
D Elevators and escalators D N/A
A5.213.1
D Steel framing D N/A
* Includes hotels/motels and high-rise residential buildings
** For alterations;,; $1,000,000 BPV and affecting > 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply
with CMC 18.30.130 instead.
2. Photovoltaic Systems
A. D Residential new construction (for low-rise residential building permit applications submitted after 1/1 /20). Refer to 2019 California
Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic
requirement (28 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(8)
(high-rise residential) or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PV offset option is selected.
Floor Plan ID (use additional CFA #d.u. Calculated kWdc*
sheets if necessary)
Total System Size:
kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.)
*Formula calculation where CFA = conditional floor area, #du = number of dwellings per plan type
If proposed system size is less than calculated size, please explain.
Exception
D
D
D
D
kWdc
8. D Nonresidential new construction or alterations ~$1 ,000,000 8PV and affecting ~75% existing floor area, or addition that increases roof
area by ~2,000 square feet Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to
high-rise residential and hotel/motel buildings.
Choose one of the following methods:
□ Gross Floor Area (GFA) Method
GFA:
D If< 1O,OOOs.f. Enter: 5 kWdc
Min. System Size:
D If;?: 1O,OOOs.f. calculate: 15 kWdc x (GFA/1O,OOO) **
kWdc
**Round building size factor to nearest tenth, and round system size to nearest whole number.
□ Time-Dependent Valuation Method
Updated 8/15/20 19 3
City of Carlsbad Climate Action Plan Consistency Checklist
Annual TDV Energy use:*** ______ x .80= Min. system size: _____ kWdc
***Attach calculation documentation using modeling software approved by the California Energy Commission.
3. Water Heating
A. D Residential and hotel/motel new construction
Please refer to CMC sections 18.30.1 50 and 18.30.170 when completing this section.
D For systems serving individual dwelling units choose one:
D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise
residential only)
D Heat pump water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise
residential hotel/motel) or CA Energy Code section 150.1(c) 14 (low-rise residential)
D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher
D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors
D Exception:
D For systems serving multiple dwelling units, install a central water-heating system with all of the fo llowing:
D Gas or propane water heating system
D Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low-
rise residential)
D Solar water heating system that is either:
D .20 solar savings fraction
D .15 solar savings fraction, plus drain water heat recovery
D Exception:
B. D Nonresidential new construction
Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section.
D Water heating system derives at least 40% of its energy from one of the following (attach documentation):
D Solar-thermal D Photovoltaics D Recovered energy
D Water heating system is (choose one):
D Heat pump water heater
D Electric resistance water heater(s)
□Solar water heating system with .40 solar savings fraction
D Exception:
Updated 8/15/2019 4
City of Carlsbad Climate Action Plan Consistency Checklist
4. Electric Vehicle Cha in
A. TI Residential New construction and major alterations*
~se refer to Carlsbad Ordinance CMC section 18.21.140 when com letin this section.
Oti and two-family residential dwelling or townhouse with attached garage:
' One EVSE Ready parking space required □Exception :
□ Multi-family residential· □ Exception ·
Total Parking Spaces EVSE Spaces
Proposed Capable I Readv I
I I
Calculations: Total EVSE spaces= .10 x Total parking (rounded up to nearest whole number)
EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest whole number)
EVSE other= Total EVSE spaces -EVSE Installed
(EVSE other may be "Capable," "Ready'' or "Installed.")
Installed Total
*Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation ;:: $60,000
or indude an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit
valuation ;:: $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing
systems are proposed.
B D Nonresidential new construction (includes hotels/motels) □ Exception ·
Total Parking Spaces EVSE Spaces
Proposed Capable I Ready I Installed l Total
I I I
Calculation: Refer to the table below:
Total Number of Parking Spaces provided Number of required EV Soaces Number of reauired EVSE Installed Spaces
□ 0-9 1 1
□ 10-25 2 1
□ 26-50 4 2
□ 51-75 6 3
□ 76-100 9 5
□ 101-150 12 6
□ 151-200 17 9
□ 201 and over 10 percent of total 50 oercent of Reau ired EV Spaces
Updated 8/15/2019 5
City of Carlsbad Cl imate Action Plan Consistency Checklist
5. D Transportation Demand Management (TOM): Nonresidential ONLY
An approved Transportation Demand Management (TDM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT.
City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TDM plan. If TDM is applicable to your
permit, staff will contact the applicant to develop a site-specific TDM plan based on the permit details.
Acknowledgment:
Employee ADT Estimation for Various Commercial Uses
EmpADTfor
first 1,000 s.f.
EmpADTI
1000 s.f.1
Office (all)2 20
Restaurant 11
Retaib 8
Industrial 4
Manufacturing 4
Warehousin 4
1 Unless otherwise noted, rates estimated from /TE Trip
Generation Manual, 10th Edition
13
11
4.5
3.5
3
1
2 For all office uses, use SAN DAG rate of 20 ADT/1 ,000 sf to
calculate employee ADT
3 Retail uses include shopping center, variety store, supermarket,
gyms, pharmacy, etc.
Other commercial uses may be subject to special
consideration
Sample calculations:
Office: 20,450 sf
1. 20,450 sf/ 1000 x 20 = 409 Employee ADT
Retail: 9,334 sf
1. First 1,000 sf = 8 ADT
2. 9,334 sf -1,000 sf= 8,334 sf
3. 8,334 sf / 1,000 x 4.5 + 8 = 46 Em lo ee ADT
I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should
my permit require a TDM plan and understand that an approved TDM plan is a condition of permit issuance.
Applicant Signature: __________________ _ Date: ______ _
Person other than Applicant to be contacted for TDM compliance (if applicable):
Name (Printed): __________________ _ Phone Number: _____ _
Email Address: --------------------
Updated 8/ I 5/20 I 9 6
CARLSBAD CBR2019-2546
9/21/2019
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: CBR2019-2546 JURISDICTION: CARLSBAD
PROJECT ADDRESS: 2717 WILSON STREET
FLOOR AREA:
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 9/21/2019
FOREWORD (PLEASE READ):
STORIES:
HEIGHT:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 9/17/2019
PLAN REVIEWER: Bert Domingo
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC,
2015 UPC, 2015 UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this 11st (or a copy) where each
correction Item has been addressed, I.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up 11st when you submit the revised plans.
CARLSBAD CBR2019-2546
9/21/2019
PLANS
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil is complete.
2. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
3. Plans deviating from conventional wood frame construction shall have the
structural portions signed and sealed by the California state licensed engineer or
architect responsible for their preparation, along with structural calculations.
(California Business and Professions Code).
STRUCTURAL
4. Provide truss details and truss calculations for this project. Specify truss
identification numbers on the plans.
Roof trusses to be a deferred submittal. Refer to sheet T-1 for notes
5. Please provide evidence that the engineer-of-record (or architect) has reviewed
the truss calculation package prepared by others (i.e., a "review" stamp on the
truss calculations or a letter). CBC Section 107.3.4.1.
Roof trusses to be a deferred submittal. A truss review letter shall be provided when truss drawings and
calculations are submitted to the City ELECTRICAL
for review. Refer to sheet T-1 for notes
6. Show on the plan the amperage of the electrical service, the location of the
service panel and the location of any sub-panels. If the service is over 200
amperes, submit a single line diagram, panel schedules, and provide service
load calculations.
A 200Amp panel shall be provided. refer to sheet 2.1 note #10
7. Note on the plans that receptacle outlet locations will comply with CEC Article
210.52.
Note added. refer to sheet 2.3 "Power and Lighting Notes" #19
CARLSBAD CBR2019-2546
9/21/2019
8. Include on the plans the following specifications for electrical devices installed in
dwellings: CEC Article 210 & 406
a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all
receptacles in a dwelling).
b) Weather resistant type for receptacles installed in damp or wet locations
(outside).
c) Arc-fault protection for all outlets (not just receptacles) located in rooms
described in NEC 210.12(A): Kitchens, laundry areas, family, living,
bedrooms, dining, halls, etc.
d) GFCI protected outlets for locations described in NEC 210.8(A): Laundry
areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors,
within 6' of a sink, etc.
Notes updated, refer to sheet A2.3
PLUMBING
9. Show water heater size (1 st hour rating), type, and location on plans. Note: For
both new dwellings and additions the Energy Standards (150.0(n)) requires a gas
input rating of 200,000 Btu for both tank and instantaneous gas water heaters.
(Also) Provide a gas piping design for the gas system.
Notes updated, refer to sheet A2.1 Keynote #5 + A4.0 building section #2
10. An instantaneous water heater is shown on the plans. Please Include a gas
pipe sizing design (Isometric or pipe layout) for all gas loads.
a) The gas pipe sizing for a tank type water heater shall be based upon a
minimum 199,000 Btu gas input rating. Energy Standards 150.0(n).
Gas Diagram added, refer to sheet A2.1
11. Specify on the plans: Water conserving fixtures: New water closets shall use no
more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8
GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 1.8
GPM of flow. CPC Sections 407,408,411,412.
Notes updated, refer to sheet A-1 "Green Building Notes"
12. Specify on the plans whether the existing house was built before or after 1994.
For additions or improvements to a residence built before 1994, note on the
plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons
of water per flush, urinals that use more than one gallon of water per flush,
showerheads that have a flow capacity of more than 2.5 gallons of water per
minute, and interior faucets that emit more than 2.2 gallons of water per minute)
shall be replaced. Certification of compliance shall be given to the building
inspector prior to final permit approval. California SB407.
Notes updated, refer to sheet T1 under "Project Scope"
CARLSBAD CBR2019-2546
9/21/2019
MISCELLANEOUS
13. Title 24 calculations did not seem to have included the requirements of the new
exterior walls.
Calculations updated
14. Please show the recommended insulation for the roofs and the walls on the
sections.
Insulation notes updated. refer to sheet A-4 and sheet A
15. R3's:
For the following types of projects, a minimum of one "EVSE (Electric Vehicle Supply
Equipment) ready space" shall be installed:
• New one-and two-family dwellings
• Townhouse style with attached garages
• Major residential renovations (defined as renovations/additions having a
valuation of $60,000 or more)
• Any project with an electrical service upgrade (including upgrades for PV
installation)
The "EVSE ready space" shall have the following: Panel capability, 40A 2 pole breaker,
1" raceway, No. 8 conductors installed to the anticipated charger location.
EVSE outlet added refer to sheet A2.3
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes liil No □
3-Car garage and entry tower added to scope of work
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Bart Domingo at EsGil. Thank you.