HomeMy WebLinkAbout2825 STATE ST; 101; CBC2018-0435; Permit(city of
Carlsbad
Commercial Permit
Print Date: 05/06/2019
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
Description:
Applicant:
2825 State St, 101
BLOG-Commercial
2032940100
$68,974.33
B
HANDEL'S ICE CREAM: 1,483 SF T.I.
Owner:
Work Class: Tenant Improvement
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Plan Check#:
FRANK WRIGHT
1152 E 7Th St
COOWNER SATTERLY RUSSELL L & SATTERLY
SUSAN L
Ontario, CA 91764-1006
310-750-8939
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
2825 State St
CARLSBAD, CA 92011
ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL
MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL
PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL
S61473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-COMMERCIAL
Total Fees: $1,031.60 Total Payments To Date: $1,031.60
Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Final
Inspection:
Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES ff APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Permit No: CBC2018-0435
Closed -Finaled
07/31/2018
10/24/2018
TFraz
4/9/2019 11:16:53AM
$0.00
$490.17
$343.12
$60.00
$45.00
$71.00
$3.00
$19.31
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-6D2-2700 I 760-6D2-8560 f I www.carlsbadca.gov
...
' I
Ccicyof
Carlsbad
COMMERCIAL
BUILDING PERMIT
APPLICATION
B-2
Plan Check (B[i9-CJ8-6L/:3)
Est. Value itJ lo z; 9 f'-/, 33
PC Deposit --~------
Date If 3J / /8=
JobAddress rl,8?.S' $11\Tt-'-'· ff /Dl Suite:_,,;;z_.._APN: ?.,z:,7:,-'2-<j'(-D/
Tenant Name: \\to,\DGL'S \Ct-G~~ CT/Project#: _________ Lot#: ___ _
Fire Sprinklers: yes /(i[i} Air Conditioning: ~/no
BRIEF DESCRIPTION OF WORK: T6r-lf\-N:C .:X:t::'f'l~oVE.1Al51'-l, J:O Co('LSTµ,cT /' \C6-Ci26A-1-\ SI~
\ n\-e.-1o-r-{-.-c.wit ,1 ~l-€chicct l '-I.WI b,"' 6c-l--lA1" I c.""1-1,uol2-K,
D Addition/New: ___________ .New SF and Use, ___________ New SF and Use,
____ Deck SF, Patio Cover SF (not including flatwork)
® Tenant Improvement: I Lt It,?, SF,
_____ SF,
Existing Use __ P.::,,:c_ ___ Proposed Use---"-----
Existing Use Proposed Use _____ _
0 Pool/Spa: _____ SF Additional Gas or Electrical Features? ____________ _
D Solar: ___ KW, __ Modules, ___ Mounted, Tilt: Yes/ No, RMA: Yes/ No, Panel Upgrade: Yes/ No
D Plumbing/Mechanical/Electrical Only: _________________________ _
□ Other: ____________________________________ _
APPLICANT (PRIMARY) PROP,j:~TY OWNER
Name: Ff':MJl< IJ2td,6ff NarKii'_SS_=:ia__.,......,.ri=~=-----~~
Address: \\5::L e=-. "'J l"tt-6T Address: 3.:£"'2..c:>7k&it\A. sf--~ -f£ D'1
City: ()cltM< 0 State: CA-Zip: q r71,ij City: Sa~ "D\~'7 Q State:CA-Zip: 17..lo(o
Phone: '3!Q 75:? f!li3J Phone: r_;Jto..Q\ ..:Z.17 -3]WO
Email: fiorjl,4-0g>z.@Q,MAtl.(e>M. Email: ________________ _
DESIGN PROFESSIONAL CONTRACTOR BUSINESS C Tl
Name: I \q;_ K P.,6t_£.1 Name: 1{sj;.;f{;,8: ~ ~Gl,,~ L ifT
Address: '-fl'ba3 \½,<>)tloft:llz.. 11,L.vo ~ 3a.Address: 19 2c, A.(u;;....-.;:r;;: S~
City: l(W),IIIIJ,t.~ State: CP.. Zip: 902.(pD Citv:Qc,.;nS1d-e. State: C)\-Zip:zt:>Slf
Phone: "3t,0-L{33-'-l,02.o Phone: O(b6,)q"70-3':{j'"o/
Email:_____________ Email: · C .SloWC::.i~C l. TVT-<:: c,,11
Architect State License: I! · 'l..'2..w·'2..."t-State License: fol '$taO~( Bus. Li'cimse: I Z '-12 'rt/ab
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law
{Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he/she is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}).
1635 Faraday Ave Carlsbad, CA 92008
B-2
Ph: 760-602-2719 Fax: 760-602-8558
Page 1 of 2
Email: Building@carlsbadca.gov
Rev. 06/18
\
......
( OPTION A): WORKERS'COMPENSATION DECLARATION:
I hearby affirm under penalty of perjury one of the following declarations:
□ I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued.
g{have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, fo_r thE;!,
~y"'':"orkers' Ct?'rrs~o11LU!~carrzr{4d policy nun:iber are: lnsuranc Com any Name: •
Polley No. l G, -Expiration Date: 1 ·
□ Certificate of Exemption: I certify that in the performance of the work for which this permit is issu'ed, I shall not employ any·person in any manner so as to be come
subject to the workers' compensation Laws of California. WARNING: Failure to secu orkers compens.-tipn coverage Is unlawful, and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition t~ the cost of 110~ensaiion, damages as provided fo~ in Section 3706 of the Labor Cd'de, •'
interestandattorney'sfees. / l // · · ;_ L.,,.J h ~
CONTRACTOR SIGNATURE: { 7 ~y' 7/ l'j{AGENT DATE:~
( OPTION B ): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the foll.owing reason:
□ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an oWner of ProJ)eit:y who builds or improves thereon, and who does such woi-k
himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, .the building or improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of s~le). • , ·
□ I, as owner of the property, am exclusively contracting with licensed contractors to ~onstruct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
□ I am exempt under Section ________ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No
2. I (have/ have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/
contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the followlng persons to provide the work indicated (include name/ address/ phone/ type of work):
OWNER SIGNATURE: __________________ □AGENT DATE: _____ _
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name: ______________________ _ Lender's Address: ______________________ _
ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes ~o .
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes /J..No
rs the facillty to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes )(No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLfss° THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE CJTY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF
THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations overS'O' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized
by such permit is not commenced within 180 days troy, thjdclfe of such permit or if the building or work authorized by such permit is suspended or abandoned at any time
after the work is commenced for a period of 1,:l daYf(Se,1orfl06.4.4 Uniform Building Code).
APPLICANT SIGNATURE: , u1, ~;' , DATE, 7-:s, -\e
1635 Faraday Ave Carlsbad, CA 92008
B-2'
Ph: 760-602-2719 Fax: 760-602-8558
Page 2 of 2
Email: Building@carlsbadca.gov
Rev. 06/18
PERMIT INSPECTION HISTORY REPORT (CBC2018-0435)
Permit Type; BLDG-Commercial Application Date: 07/31/2018 Owner:
Work Class: Tenant Improvement Issue Date: 10/24/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 10/07/2019 Address:
Scheduled
Date
Actual
Start Date
03115/2019 03/15/2019
03(18/2019 03(1812019
04/01/2019 04/01/2019
04/09/2019 04/09/2019
May 06, 2019
IVR Number: 12888
Inspection Type Inspection No.
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLOG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
BLDG-33 Service
Change/Upgrade
086181-2019
Checklist Item
BLDG-Building Deficiency
BLOG-33 Service
ChangelUpgrade
086329-2019
BLDG-Final
Inspection
BLDG-Final
Inspection
Checklist Item
BLDG-Building Deficiency
087455-2019
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
088247-2019
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Inspection Status Primary Inspector
COMMENTS
Need to check for daylighting requirements
Passed Tim Frazee
COMMENTS
Passed Tim Frazee
COMMENTS
Partial Pass Tim Frazee
COMMENTS
Need some final paperwork
Need exterior light at entrance door
Passed Tim Frazee
COMMENTS
Need some final paperwork
Received B-52 need Title 24 and recycling
Need exterior light at entrance door
Exterior lights installed 419119
COOWNER SATTERLY RUSSELL L
& SATTERLY SUSAN L
TOWN OF CARLSBAD AMENDED
2825 State St, 101
Carlsbad, CA 92008-1631
Re inspection Complete
Passed
Yes
Yes
Yes
No
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Relnspection Incomplete
Passed
Yes
Yes
Yes
Yes
Yes
Complete
Passed
Yes
Yes
Yes
Yes
Yes
Page 3 of 3
PERMIT INSPECTION HISTORY REPORT (CBC2018-0435)
Pcm1it Type: BLDG-Commercial Application Date: 07/31/2018 Owner:
Work Class: Tenant Improvement Issue Date: 10/24/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 10/07/2019 Address:
Scheduled
Date
01/03/2019
Actual
Start Date
01/03/2019
01/07/2019 01/07/2019
01/22/2019 01/22/2019
02/11/2019 02111/2019
02/20/2019 02/2012019
02/26/2019 02/26/2019
May 06, 2019
IVR Number: 12888
Inspection Type Inspection No.
BLDG-11
Foundatlon/Ftg/Pier
s (Rebar)
080352-2019
Checklist Item
BLOG-Building Deficiency
BLDG-84 Rough
Combo(14,24,34,44)
080351-2019
Checklist Item
BLDG-BuHding Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
BLDG-84 Rough
Combo(14,24,34,44)
080617-2019
Checklist Item
BLDG-44
Rough-Ducts-Dampers
BLDG-17 Interior
LathfDrywall
081720-2019
Checklist Item
BLDG-Building Deficiency
BLDG-12 SteelfBond 083488-2019
Beam
Checklist Item
BLOG-Building Deficiency
BLDG-66 Grout 084111-2019
Checklist Item
BLDG-Building Deficiency
BLDG-34 Rough
Electrical
084614-2019
Checklist Item
BLDG-Building Deficiency
BLDG-85 T-Bar,
Ceiling Grids,
Overhead
084615-2019
Inspection Status Primary Inspector
Passed Tim Frazee
COMMENTS
Rebar in four (4) footings OK 01/03/19
Partial Pass Tim Frazee
COMMENTS
Partial Pass Tlm Frazee
COMMENTS
line sets for four(4) split units and
condensate rough (4)
Partial Pass Paul Burnette
COMMENTS
Passed Tlm Frazee
COMMENTS
Passed Tim Frazee
COMMENTS
Trash enclosure OK to grout 2/20/19
Partial Pass Tim Frazee
COMMENTS
Rough electrical in walls
Need to check for daylighting requirements
Partial Pass Tim Frazee
COOWNER SATTERLY RUSSELL L
& SATTERLY SUSAN L
TOWN OF CARLSBAD AMENDED
2825 State St, 101
Carlsbad, CA 92008-1631
Reinspection Complete
Complete
Passed
Yes
Reinspection Incomplete
Passed
No
No
No
No
No
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
No
Complete
Passed
No
Complete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Relnspection Incomplete
Page2of3
PERMIT INSPECTION HISTORY REPORT (CBC2018-0435)
Permit Type: BLDG-Commercial Application Date: 07/31/2018 Owner: COOWNER SATTERLY RUSSELL L
& SATTERLY SUSAN L
Work Class: Tenant Improvement Issue Date: 10/24/2018 Subdivision: TOWN OF CARLSBAD AMENDED
Status: Closed -Finaled Expiration Date: 10/07/2019 Address: 2825 State St, 101
Carlsbad, CA 92008-1631
tVR Number: 12888
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
11/28/2018 BLDG-21 077299-2018 Cancelled Tim Frazee Reinspection Complete
Underground/Underf
loor Plumblng
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial D1/'N see plans Yes
11/08/2018 11/08/2018 BLDG-14 075554-2018 Partial Pass Paul Burnette Reinspection Incomplete
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
11/2012018 11/20/2018 BLDG-21 076573-2018 Partial Pass Tim Frazee Reinspectlon Incomplete
Underground/Underf
loor Plumbing
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Partial DV'N see plans Yes
11/27/2018 11/27/2018 BLDG-31 076978-2018 Passed Tim Frazee Complete
Underground/Condu
it -Wiring
Checklist Item COMMENTS Passed
BLDG-Building Deficiency UG for floor boxes 11/27/18 Yes
11/30/2018 11/30(2018 BLDG-21 077491-2018 Partial Pass Tim Frazee Reinspection Incomplete
Underground/Underf
loor Plumblng
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial D1/W see plans Yes
12/03/2018 12/03/2018 BLDG-21 077647-2018 Passed Tim Frazee Complete
Underground/Underf
loor Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial DVW see plans Yes
Grease Interceptor OK 12/03/18
12/27/2018 12/27/2018 BLDG-24 079924-2018 Passed Tim Frazee Complete
Rough/Topout
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-34 Rough 079923-2018 Partial Pass Tim Frazee Reinspection Incomplete
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Rough electrical in walls Yes
May 06, 2019 Page 1 of 3
✓• EsG1I
A SAFEbuilfCompany
DATE: 10/4/2018
JURISDICTION: Carlsbad
□ APPLICANT
□ JURIS.
PLAN CHECK#.: PC2018-0033
PROJECT ADDRESS: 2825 State St.
SET: II
PROJECT NAME: Retail Space / Subdivision Tenant Improvement
□
□
□
□
□
~
□
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did adv:7·se the pplicant that the plan check has been completed.
Person contacted: /Js::., Telephone#:
Date contacted: (by:~ ) Email:
Mail Telephone Fax In Person
0 REMARKS:
By: Jason Pasiut
EsGil
9/27/2018
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
✓• EsG1I
DATE: 8/10/2018
JURISDICTION: Carlsbad
□ APPLICANT
□ JURIS.
PLAN CHECK#.: CBC2018-0435
PROJECT ADDRESS: 2825 State St. #1
SET: I
PROJECT NAME: Handle's Ice Cream Tenant Improvement
□
□
□
□
□
~
□
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Framk Wright
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Telephone#: 310-750-8939 Person contacted: Frank Wri~\
Date contacted: ~~ (by~ ) Email: fwright082@gmail.com
Mail Telephone Fax In Person
REMARKS:
By: Jason Pasiut
EsGil
8/2/2018
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad CBC2018-0435
8/10/2018
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK#.: CBC2018-0435
OCCUPANCY: B
TYPE OF CONSTRUCTION: V-B
ALLOWABLE FLOOR AREA: within
SPRINKLERS?: NO
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 7/31/2018
DATE INITIAL PLAN REVIEW
COMPLETED: 8/10/2018
FOREWORD (PLEASE READ):
JURISDICTION: Carlsbad
USE: Ice Cream Shop
ACTUAL AREA: 1,483sf
STORIES: 1
HEIGHT: unchanged
OCCUPANT LOAD: 34
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 8/2/2018
PLAN REVIEWER: Jason Pasiut
This plan review is limited to the technical requirements contained in the California version of
the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy conservation, noise attenuation and access for
the disabled. This plan review is based on regulations enforced by the Building Department.
You may have other corrections based on laws and ordinances enforced by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
---·----···
Carlsbad CBC2018-0435
8/10/2018
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one
of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-
2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and
Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake
Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of
plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City
Planning, Engineering and Fire Departments until review by EsGil is complete.
• PLANS
1. Please update the following sheets / notes / details:
a) The as-built floor plan shows the new restroom being installed under
permit application CBC2018-0033 implying that this bathroom will also be
constructed under this permit application. Please clarify.
b) Door note 3 on sheet A5 to state 34" to 44". 11 B-404.2.7.
c) Door #2 is shown on the door schedule to be a 3-0 x 7-0 door, yet the
floor plan shows a double leaf door. Show this door to be in compliance
with the accessibility and egress requirements of CBC 11 B-404.2.2.
2. Please provide engineer justification / design for the new opening being cut into
the existing CMU wall for the Sunday refrigerator.
• MECHANICAL/ ELECTRICAL/ PLUMBING
3. Please show GFCI protected receptacles within 6" of all sinks. CEC210.8.
4. New mechanical equipment is also being installed under permit application
CBC2018-0033. Please clarify which permit application will cover which HVAC
system and show all details on appropriate plans for the following:
a) Show on the plans how the installation of new mechanical equipment on
the roof will meet the seismic design requirements of ASCE 13.2.1
general design, 13.4 anchorage, and applicable section of 13.6 unless
exempted by 13.1.4.
b) Show on the plans that the existing structural framing is sufficient to
support the weight of the new RTU being installed. CMC 303.8.
Carlsbad CBC2018-0435
8/10/2018
5. Please consult with the City of Carlsbad Wastewater Division as to whether they
require a grease interceptor and sample box. Show all details on the plumbing
plans if required.
6. Each business establishment required shall have a gravity grease interceptor
which shall serve that establishment. Please verify with the City of Carlsbad to
determine whether a common gravity grease interceptor is approved.
7. Please show on the plumbing plan that the drainage piping is vented by means
of one or more vent pipes with an aggregate cross-sectional area that is not less
than that of the sewer pipe. CPC 904.1.
8. Show clean outs at all hand sinks per plumbing note 19 sheet P1, and the mop
sink within the dish line area. CPC 707.
9. Describe the method of compliance for temperature limitations for the following
fixture types: private lavatories (120 degrees), public use lavatories and bidets,
(limited to 110 degrees) and (bathtubs and showers (120 degrees)). Note: The
water heater thermostat may not be used for compliance with this Code section.
CPC 408.3, 409.4, 410.3, 421.2, and Energy Standards 11 0(C)3.
• WALK IN COOLER
10. Provide the manufacturer standard plans and installation instructions/listing
information for the cooler walls and refrigeration equipment being proposed.
CMC 935.
a) Show electrical loads and show that the equipment meets UL 471 and 427.
b) Show connection details for corners and roof including fasteners.
c) Show foam thickness and flame-spread information.
11. Show location of indirect drain/ floor sink and detail drain pipe size and required
airgap. CPC418.4.
12. Refrigerated Spaces that are less than 3,000 square feet shall meet the
requirements of the Appliance Efficiency Regulations for walk-in coolers or
freezers contained in the Appliance Efficiency Regulations (California Code of
Regulations, Title 20, Sections 1601 through 1608). Note on the plans whether
this installation meets these requirements. CEC 120.6 (a)
13. Please note or show that all electrical penetrations into the cooler shall be sealed
per section 300-7 of the NEC.
14. Please provide a roof plan showing the location of the new condensing unit.
• END OF REVIEW
Carlsbad CBC2018-0435
8/10/2018
To speed up the review process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number, calculation
page, etc.
Please indicate here if any changes have been made to the plans that are not a result
of corrections from this list. If there are other changes, please briefly describe them
and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate: □ Yes □ No
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite
208, San Diego, California 92123; telephone number of 858/560-1468, to perform the
plan review for your project. If you have any questions regarding these plan review
items, please contact Jason Pasiut at Esgil. Thank you.
Carlsbad CBC2018-0435
8/10/2018
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Jason Pasiut
BUILDING ADDRESS: 2825 State St. #1
BUILDING OCCUPANCY: B
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
1483 46.51
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
---------------
1997 UBC Buildin Permit Fee .... ---------~g----~
1997 UBC Plan Check Fee -~
Type of Review: [2J Complete Review
D Repetitive Fee
,.. Repeats
J
Comments:
D Other
D Hourly
EsGil Fee
PLAN CHECK#.: CBC2018-0435
DATE: 8/10/2018
Reg. VALUE ($)
Mod.
68,974
68,974
D Structural Only
1---------<I Hr. @ *
$296.01 I
Sheet 1 of 1
STRUCTURAL CALCULATIONS
FOR ONE STORY COMMERCIAL PROPERTY
LOCATED AT
2825 ST A TREET
CARLSBW.ffitWJ ORNIA
PREPARED BY
KONSTRO DESIGN & ENGINEERING INC.
1608 Centinela Avenue
Suite 13
Inglewood, California 90302
Phone: 310-216-6944
Fax: 310-216-0091
Email: Konstro2@att.net
KONSTRO · DESIGNS
PH: (310) 216-6944 FAX: (310) 216-0091
JOB#_·...---------------------
oATE: ___ o 9---'--+-\ _o _1 +-/ ,..,;;~----------
JOB ADDRESS: i<tZ5 S']Fy1€ o/1 t2-~e-r ,
C ~L-.S b~ 1 Cft °1'2-Oo,8'
OWNER:· ____________________ _
DRAFTSMAN/ARCHITECT: ____________ _
ROOJ' LOAD:ING CB:n.J:NG LOADING
L.L == -z_.oi/ ,·z.. .,., .. ~-,0 6 .0i/
SBEAT. == ~ • 5f / I 7.... 9 ~~0 ,-.vo ,.0 ,v~
ROOF. -= '21 £1/1 'l... ~ j, ~-<-~ '1-
JiO:tST =:s 2 • "'.a/ /. 2. -~ ~ ~ ~-~ ~ N0~1 ~
INSU. ~ 1 .. 0f/j 1-\ EXPll'EO m
C..e,L ~-b•0~/1-Z.. -~f'TJO-.:ti ,
FLOOR LOADING
L.L = i/
stm FLOOR -2.51/
li'LOORDlG -1.0i/
JOIST . = 5.0i/
CEILDIG = 6.0#/
TO!L'AL W ,:;,. -g; -f./, ~i/ / l--~ CM.~~~-,
SPECDrJ:CMti:ON$ : ~:_ °.F CA_~ .
T017tL.W ·= ii
Concrete * Std. Grade fc' = 2500 psi .
Concrete block * AS.DI c-90 •.-Gl;ade N, non-continuous
iDspection
Mortar * · 'l'ype_ S vi.th 1 part Portland cement, ·
. ½ part lime . & 4 pa.rt;;s sand
Grout * 1 part P9rtland cement, 3 parts sand,
2 part.a pea gravel. m;n;tm.DD fo': 2000 psi * AS'lM ~-615 Grade 40 (#6 and smal.ler)
. Grade .60 (#7 ~ larger)
Struc~a1 · steel * Shapes ASn.f A-36
Bol.ts .
WeJding
Plywood
Subject
Roof sheathing
Floor sheathing
Soils
Co1Ullm8 ASD« A-53 Grade B · · * ASTM A_.307 * A11 wel.cling sbaJ l · be done by certified
wel~• using B-60 B1ectrodes
~ Douglas f4' par grading rule #16 WCLJ:B
sizes per· PS20:-70 · ·
Li.gh~ f.,.am;ng, joiata, planks, beams
4" ~-.. lfida Grade #2
Po_sts and beams ovar 4" wide Grade #1
On1eas . noted otharvise on the p:J.ans
* Douglas fir par PS:I-74 with ~ior·glue
* * --r,z~2:'""C(:':t"'_ ...,(~) L':"':::1'."":"'"'",w---&Q--9--C-,i-D-1-..,~-N-fn_,L-_t_N---:-C,~-----.... --• •
* * -~fH.._\....._o_\J'.>_~~ .... L--f~'=----,-11--o .... c-~f .... 5_f2 ______ _
1608 CENTINELA.AVENUE, SUITE 13, INGLEWOOD, CA-90302
BeamChek v2016 licensed to: KONSTRO DESIGNS Reg# 7992-66673
2825 STATE STREET, CARLSBAD, CA ROOF RAFTERS
RR-1
Selection
Date: 9/11/18
I (2) 2x 10 DF-L #2@ 16 in oc Lu= 0.0 Ft
Conditions NOS 2015, Repetitive Use
Min Bearing Area R1 = 0 8 in' R2= 1 0 in' (1 5) DL Defl= 0 38 in
Beam Span 17.0 ft Reaction 1 LL 227# Reaction 2 LL
Beam Wt per ft 0# Reaction 1 TL 487# Reaction 2 TL
Attributes
Actual
Critical
Status
Ratio
Adiustments
Loads
Bm Wt Included 0# MaximumV 621 #
Max Moment 2565'# Max V (Reduced) 585#
TL Max Defl L/240 TL Actual Defl L/378
LL Max Defl L/360 LL Actual Defl L/ >1000
Section /in'\ Shear /in') TL Defl (in) LL Defl
42.78 27.75 0.54 0.16
27.04 4.88 0.85 0.57
OK OK OK OK
63% 18% 63% 28%
Fb 1nsi) Fv (psi) E (psi X mil)
Reference Values 900 180 1.6
Adiusted Values 1139 180 1.6
CF Size Factor 1.100
Cd Duration 1.00 1.00
Cr Repetitive 1.15
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00
Cl Stability 1.0000 Rb= 0.00 Le= 0.00 Ft
Uniform LL: 27 Uniform TL: 46 = A
Point TL
B = 163
C = 163
Distance
10.0
14.0
I Uniform Load A I
Pt loads: I [ID [9 I Al----------=='-------'='----------!6
Fe I rnsi\
625
625
1.00
R1 = 487 R2 = 621
SPAN= 17 FT
Uniform and partial uniform loads are lbs per lineal ft.
Notes EQUIPMENT LOAD
L= 488.0 lbs
P = 488/4 (POINT SUPPORTING THE LOAD)= 122#
------· .... ~------~-.
227#
621 #
BeamChek v2016 licensed to: KONSTRO DESIGNS Reg# 7992-66673
2825 STATE STREET, CARLSBAD, CA HEADER AT OPENING
HDR-1 Date: 9/11 /18
Selection I T 12x 4x 1/4 50 ksi Steel Tube Lateral Support:@ Bearing Points!
Conditions Actual Size is 4 x 12 in.
Min Bearing Length R 1 = 0 5 in R2= 0 5 in (1 0) DL Defl= 0 03 in
Attributes
Actual
Critical
Status
Ratio
Adiustments
Loads
Beam Span
Beam Wt per ft
Bm Wt Included
Max Moment
TL Max Defl
LL Max Defl
Section (in')
21.10
4.12
OK
20%
Ref. Value Fy
Adiusted Values
YP Factor
8.5 ft
25.82 #
219 #
10299 '#
L/ 180
L/240
Shear /in'l
6.00
0.24
OK
4%
Fb (osi)
50000
30000
0.60
Reaction 1 LL 1360 # Reaction 2 LL
Reaction 1 TL 4846# Reaction 2 TL
MaximumV 4846#
Max V (Reduced) N/A
TL Actual Defl L/ >1000
LL Actual Defl L/ >1000
TL Defl linl LL Defl
0.04 0.01
0.57 0.43
OK OK
7% 3%
Fv '"sil E lnsj X mil)
50000 29.0
20000 29.0
0.40
Par Unif LL Par UnifTL Start
6
R1 = 4846
320
H
SPAN= 8.5 FT
H = 552
I= 563
6
R2 = 4846
Uniform and partial uniform loads are lbs per lineal ft.
0
0
1360#
4846#
End
8.5
8.5
BeamChek v2016 licensed to: KONSTRO DESIGNS Reg# 7992-66673
2825 STATE STREET, CARLSBAD, CA HEADER AT 3FT OPENING
Date: 9/11/18 HDR-2
Selection I T 4x 2x 1/4 50 ksi Steel Tube Lateral Support: @ Bearing Pointsl
Conditions Actual Size is 2 x 4 in.
Min Bearing Length R1= 0.5 in. R2= 0.5 in. (1.0) DL Defl= 0.03 in
Beam Span 4.0 ft
Beam Wt per ft 8.81 # Reaction 1 TL 1143 # Reaction 2 TL
Attributes
Actual
Critical
Status
Ratio
Adiustments
Loads
Bm Wt Included
Max Moment
TL Max Defl
Section lin'l
2.35
0.46
OK
19%
Ref. Value Fy
Adiusted Values
YP Factor
6
R1 = 1143
35 # MaximumV 1143 #
1143 '# Max V (Reduced) N/A
L/ 180 TL Actual Defl L/ >1000
Shear lin'l TL Defl /in)
2.00 0.03
0.06 0.27
OK OK
3% 10%
Fb lnsi) Fv (psi) E (psi x mil)
50000 50000 29.0
30000 20000 29.0
0.60 0.40
Par Uni/TL
I= 563
6
R2= 1143
SPAN= 4 FT
Uniform and partial uniform loads are lbs per lineal ft.
--·----·-·-·---
Start
0
1143 #
End
4.0
BeamChek v2016 licensed to: KONSTRO DESIGNS Reg# 7992-66673
2825 STATE STREET, CARLSBAD, CA
P-1
SUPPORTING HDR-1
Prepared by:
Selection
Conditions
[ 3 x 3 x 114 Structural Tube ASTM A500 Grade B
Actual outside dimensions: 3 x 3 inches
Date: 9/11118
Loading is concentric on a primary column member. Maximum Kl/r is 200.
Reaction 4,846 lbs Column Net Area 2.6 in' Fa
Actual Height 8 ft Fy Min Yield Stress 46,000 psi Cc
Unbraced d1 8 ft Weight p/lineal foot 8.81 lbs r
Effective Ht D 1 8 ft K (Buckling Mode) 1.00 Ex mil
kl/r ksi Area (in')
Attributes Actual 87 1.9 2.6
Critical 200 16.8 0.3
Status OK OK OK
Ratio 44% 11% 11%
16.8
111.5
1.1
29
! •' 1!: I ,.,IL:.: L! t Ur\l i..
( CHECK!D BY ·li= DATE ill JOB ;,·! SUilJECT
~ ! ,
1---~===:-~========::.===r====(:)=t:,=,..,,~---\i=\.,=f-.l-._.=~=======================j:=-_-_=_-_-~-_-_-_-_-_-_-_-_-_->,11-------·-_-i
! ?
1 ·-f4s s_-...._M_;_;:&'---__,C __ o""-'-'ti,__c._• _ __;'t:....;l'rf::t::.....:__,___'>_..........,_6::\..A---'--"' __ i--'--''1:f-----~>~~----____ i ___ _
i ---------------------------j------r 1 ~) l --· \? z 1-t, 2: 4 (, 4 (_ :\½) L-_\_) ____________ J_W_f" __
h 2... 4 8" 4 ~ J )OU--0 -::,. 1 · g ~ ~ '2 ',..l:, "'5$-,.1'!
.l -=-1.. , 2-u _?:::t-i-"--
11 ~------1----------,--------------------------n
u --r---,
j ---------1-----~
'.--------------------------------~-----
a ~•---.
---------------·---------------------»
ii l--------------------------------------ti------
~ -------------------------------------« _____ _,
I -,----------------------------------------u------
1! I' ----------------------------~----
.,
:] --------------------------------------3------
---------------------------------------~ '!
1--------------------------------------ij------~ l
______________________________________ il _____ _
II __________ 5 ____ _
·i
-----·-----'-------------~------
--------------------------------------1-----I n i'. ;---------------------------------------!!------:'
! ·1 f:
U t --------------------------------------------· i !' ; ' ~ 1--------------------------------------0------! q
\-,.------;
u
J ~ :1---------------------------------------,
ij ---------------------'-------------------~------~ n 1! • J ,i ---,,------~ i • 1 _,_,._~-------'-------------------------------~---~-e:r.:-.!-
50.0117
16'-2 518"
, I t I I
I 3·.9 117 2'-10' I "'-0117 I 5'-81/Z t 5'-0117 I
13'-T I 4'-0117 I 7-0
""'AWNING / OVE~ TO REMAIN
t ,.._7117 I 15·.n 117 15'-9117
50-0117
I 4·-4117 i
FLOOI< PLAN DIMENSIONS
SCALE: V4" = T.0-
: I :;4, l ;~•lL:..' L: t ;! :.,! t\ I~ ~
• :l I• , ' I! •. ,.
' ,·.:.::. : : !~
--........-.~·•-.,. -=:=r-'"-•"•· r« •-~ ;,:=.-~c.•~~-•-,-· _....,, ..:•~ .. -·-·• -i tHH;:10 ,,i i u:,T;; }l JDS
~~--=-..J) lL a •'-'!'.' e~ ... , .... =w j__ {2-.o of--L..o<Ai)
---~--.:.-.,.,. ·--•.--._., .. -✓•~:.->-.................. -. -r---✓----·---.,..--.-,;..,.,.,... •-::~-=-~™ i; SU!l.JECi . i!
:I
·--------------I
b,:.r.:-"'.'.jf H I v.;: 1'(J_C7 /. '?c-i1:--) t t f x 1 °hdi.J + . • ,,..--_ ~-
1 _______ ± !4'5-~ 75f:{:f1--'f&9't3<J0)/7-S :::. __ 8'4j•b ~/1 ---!---·:
1---··--:-----~---\._) r")~c,r V\N\t ·
j __ ~ vJ L 2 $'1tt:• I~. y._ 5'0 z '2. '2--3~;v~~ ~ Z-'2.·1 t<--\f-> ,--~~
I 2. 2 ; ____ _
'
------------------------·--· ~ -----=-----------------------3:----,-
f",'1-\.-0W ~~ S ~1><1.-~'\~ ''N ~~4L. ~ __ rf ____ ! ~
a
---------------------------11----· I:
\N , n+ ~ ~~ ~ Dc~4rJ ED 'T O
~----
-------------~ __ :-f __ f'rtA--_ __....5=~'------fZ-0-~----~----
----------------------------":----
~r__~_:__--------~--
,1
' ---,::.•. :-----··----------------···-·----------------------! ~
1-------------------f----
1 ~ , ____________________________ , ___ _
l ,11 i i----------------------------;:u-----
----------------------------~----
)! ___ _ ,----------------------------~
i. ~----~ ii
i ~ ;-~----
f b
r . -----------------------------~----
~ ~----------------· --··-·-~--_..,...·--
.. ,
~ ~ ~----------------------------~----
K ~ ,·-----------------------------'i-z ----~ ------------~----···--·· ..
I
....
OFFICE USE ONLY SAN DIEGO REGIONAL
HAZARDOUS MATERIALS
QUESTIONNAIRE
RECORD ID # __________________ I
PLAN CHECK # _________________ I
BP DATE
Business Name lc5--c Business Contact Telephone#
Project Address Zip Code
Mailing Address Zip Code
Project Contact LD-7so-~
The following questions represent t facility's activities, NOT the specific project description.
PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San
Diego}: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled,
applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal.
Occupancy Rating: Facility's Square Footage (including proposed project):
13. Corrosives 1. Explosive or Blasting Agents
2. Compressed Gases
5. Organic Peroxides 9. Water Reactives
6. Oxidizers 1 O. Cryogenics 14. Other Health Hazards
3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These.
4. Flammable Solids 8. Unstable Reactives 12. Radioactives
PART 11: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH -HAZARDOUS MATERIALS DIVISION !HMO): If the answer to any of the
questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, San Diego, CA 92123.
Call (858) 505-6700 prior to the issuance of a building permit.
FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy:
1.
2.
3.
4.
5.
6.
7.
8.
YES NO
D D D D D D
D D D
D
D
D D D D D
(for new construction or remodeling projects)
Is your business listed on the reverse side of this form? (check all that apply).
Will your business dispose of Hazardous Substances or Medical Waste in any amount?
Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500
pounds and/or 200 cubic feet?
Will your business store or handle carcinogens/reproductive toxins in any quantity?
Will your business use an existing or install an underground storage tank?
Will your business store or handle Regulated Substances (CalARP)?
Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)?
Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to
or reater than 1,320 allons? California's Above round Petroleum Stora e Act .
□ CalARP Exempt
I
Date Initials
□ CalARP Required
I
Date Initials
0 CalARP Complete
I
Date Initials
PART 111: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES* answer requires a stamp from APCD 10124 Old Grove Road, San
Diego, CA 92131 apcdcomp@sdcounty.ca.gov (858) 586-2650). [*No stamp required if Q1 Yes and Q3 Yes and Q4-Q6 No]. The following questions are intended
to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive
requirements contact APCD. Residences are typically exempt, except -those with more than one building+ on the property: single buildings with more than four
dwelling units; townhomes: condos; mixed-commercial use; deliberate burns; residences forming part of a larger project. rExcludes garages & small outbuildings.]
'(EJ3 NOO 1. !Q Will the project disturb 160 square feet or more of existing building materials?
2. □0 ~ Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition.
3. · ~ (ANSWER ONLY IF QUESTION 1 or 2 1S YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance
Technician?
4. D D (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification
may be required 1 O working days prior to commencing asbestos removal.
5. D ~ Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet
{www.sdapcd.org/info/facts/perrnits.pdf) for typical equipment requiring an APCD permit.
6. D D (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school
bounda
Briefly describe business activities: Briefly describe proposed project
I declare under penalty of perjury that to the best of my knowledge and belief t e responses made herein are true and correct. I I
Name of Owner or Authorized Agent Signature of Owner or Authorized Agent Date
FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: _________________ ---,-_______________ _
BY DATE· / /
EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY
COUNTY-HMO" APCD COUNTY-HMO APCD COUNTY-HMO APCD
*A stamp m this box only exempts businesses from completing or updating a Hazardous Matenals Business Plan. Other permitting requirements may stI11 apply.
HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division
LIST OF BUSINESSES WHICH REQUIRE REVIEW AND APPROVAL FROM THE COUNTY OF SAN DIEGO
DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION
Check all that apply:
AUTOMOTIVE
D Battery Manufacturing/Recycling
D Boat Yard
D Car Wash
D Dealership Maintenance/Painting
D Machine Shop
D Painting
D Radiator Shop
D Rental Yard Equipment
D Repair/Preventive Maintenance
D Spray Booth
D Transportation Services
D Wrecking/Recycling
CHEMICAL HANDLING
D Agricultural supplier/distributor
D Chemical Manufacturer
D Chemical Supplier/Distributor
D Coatings/Adhesive
D Compressed Gas Supplier/Distributor
D Dry Cleaning
D Fiberglass/Resin Application
D Gas Station
O Industrial Laundry
D Laboratory
D Laboratory Supplier/Distributor
0 Oil and Fuel Bulk Supply
D Pesticide Operator/Distributor
CHEMICAL HANDLING
D Photographic Processing
D Pool Supplies/Maintenance
D Printing/Blue Printing
D Road Coatings
D Swimming Pool
D Toxic Gas Handler
0 Toxic Gas Manufacturer
METAL WORKING
0 Anodizing
0 Chemical Milling/Etching
D Finish-Coating/Painting
D Flame Spraying
D Foundry
D Machine Shop-Drilling/Lathes/Mills
D Metal Plating
D Metal Prepping/Chemical Coating
D Precious Metal Recovery
D Sand Blasting/Grinding
D Steel Fabricator D Wrought Iron Manufacturing
AEROSPACE
D Aerospace Industry
D Aircraft Maintenance
D Aircraft Manufacturing
OTHERS AND MISCELLANEOUS
D Asphalt Plant
0 Biotechnology/Research
D Chiropractic Office
D Co-Generation Plant
D Dental Clinic/Office
D Dialysis Center
D Emergency Generator
0 Frozen Food Processing Facility D Hazardous Waste Hauler
D Hospital/Convalescent Home
D Laboratory/Biological Lab
D Medical Clinic/Office
D Nitrous Oxide (NO~) Control System
D Pharmaceuticals
0 Public Utility
D Refrigeration System
D Rock Quarry
D Ship Repair/Construction
D Telecommunications Cell Site
D Veterinary Clinic/Hospital
D Wood/Furniture Manufacturing/Refinishing
ELECTRONICS
D Electronic Assembly/Sub-Assembly
D Electronic Components Manufacturing
D Printed Circuit Board Manufacturing
NOTE: THE ABOVE LIST INCLUDES BUSINESSES, WHICH TYPICALLY USE, STORE, HANDLE, AND DISPOSE OF HAZARDOUS SUBSTANCES.
ANY BUSINESS NOT INCLUDED ON THIS LIST, WHICH HANDLES, USES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE
HAZARDOUS MATERIALS DIVISION (HMO) REVIEW OF BUSINESS PLANS. FOR MORE INFORMATION CALL (858) 505-6880.
LIST OF AIR POLLUTION CONTROL DISTRICT PERMIT CATEGORIES
Businesses, which include any of the following operations or equipment, will require clearance from the Air Pollution Control District.
CHEMICAL
47 -Organic Gas Sterilizers
32 -Acid Chemical Milling
33 -Can & Coil Manufacturing
44 -Evaporators, Dryers & Stills Processing
Organic Materials
24 -Dry Chemical Mixing & Detergent Spray
Towers
35 -Bulk Dry Chemicals Storage
55 -Chrome Electroplating Tanks
COATINGS & ORGANIC SOLVENTS
27 -Coating & Painting
37 -Plasma Arc & Ceramic Deposition Spray
Booths
38 -Paint, Stain & Ink Mfg
27 -Printing
27 -Polyester Resin/Fiberglass Operations
METALS
18 -Metal Melting Devices
19 -Oil Quenching & Salt Baths
32 -Hot Dip Galvanizing
39 -Precious Metals Refining
ORGANIC COMPOUND MARKETING
{GASOLINE. ETC)
25 -Gasoline & Alcohol Bulk Plants & Terminals
25 -Intermediate Refuelers
26 -Gasoline & Alcohol Fuel Dispensing
COMBUSTION
34 -Piston Internal -Combustion Engines
13 -Boilers & Heaters (1 million BTU/hr or larger)
14 -Incinerators & Crematories
15 -Burn Out Ovens
16 -Core Ovens
20 -Gas Turbines, and Turbine Test Cells & Stands
48 -Landfill and/or Digester Gas Flares
ELECTRONICS
29 -Automated Soldering
42 -Electronic Component Mfg
FOOD
12 -Fish Canneries
12 -Smoke Houses
50 -Coffee Roasters
35 -Bulk Flour & Powered Sugar Storage
SOLVENT USE
28 -Vapor & Cold Degreasing
30 -Solvent & Extract Driers
31 -Dry Cleaning
ROCK AND MINERAL
04 -Hot Asphalt Batch Plants
05 -Rock Drills
06 -Screening Operations
07 -Sand Rock & Aggregate Plants
08 -Concrete Batch, CTB, Concrete Mixers, Mixers
&Silos
1 O -Brick Manufacturing
OTHER
01 -Abrasive Blasting Equipment
03 -Asphalt Roofing Kettles & Tankers
46 -Reverse Osmosis Membrane Mfg
51 -Aqueous Waste Neutralization
11 -Tire Buffers
17 -Brake Debonders
23 -Bulk Grain & Dry Chemical Transfer & Storage
45 -Rubber Mixers
21 -Waste Disposal & Reclamation Units
36 -Grinding Booths & Rooms
40 -Asphalt Pavement Heaters
43 -Ceramic Slip Casting
41 -Perlite Processing
40 -Cooling Towe rs -Registration Only
91 -Fumigation Operations
56 -W\/1/TP (1 million gal/day or larger) & Pump
Station
NOTE: OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITTING AIR CONTAMINANTS MAY REQUIRE AN AIR POLLUTION
CONTROL DISTRICT PERMIT. IF THERE ARE ANY QUESTIONS, CONTACT THE AIR POLLUTION CONTROL DISTRICT AT (858) 586-2600.
\ HM-9171 (08/15) County of San Diego -DEH -Hazardol!s Materials Division
40,
ELISE ROTHSCHILD
Director
,
<n:ountp of ~an 1.lBtego
DEPARTMENT OF ENVIRONMENTAL HEALTH
FOOD AND HOUSING DIVISION
P.O. BOX 129261, SAN DIEGO, CA 92112-9261
Phone: (858) 505-6659 FAX: (858) 505-6824
1 (800) 253-9933
www.sdcdeh.org
PLAN APPROVAL SHEET
DBA: Handel's Ice Cream
SITE: 2825 State Street, Carlsbad, CA 92008
BUSINESS OWNER: LOF HELADEROS. LLC
Plans are approved contingent upon the following:
RECEIVED
OCT 2 4 2018
CITY CH' C/\FU ::;f3/\D
£3UiLDiNG Di\/1S/ON
Arlrf HARBERT
Assistant Director
DATE: 10/24/2018
PC#: 2018-FFPP-
009986
1) Department of Environmental Health IDEffi stamped plans shall be maintained at the jobsite and
available for review at the time of the inspection.
2) Changes to equipment layout, menu, or application must be submitted for approval. Changes made without
approval will make the plan approval null and void.
3) Obtain local Building Department and all applicable agencies permits and approvals PRIOR TO FINAL
INSPECTION AND APPROVAL TO OPERATE BY THIS DEPARTMENT.
4) All food and utensil-related equipment shall be certified to applicable sanitation standards by an ANSI
accredited testing agency.
5) 5-10 business days before completion of 60%-80% of construction, call (858) 505-6660 to schedule a mid-
inspection. In lieu of a plumbing inspection by DER:
a. Floor sinks shall be installed 1/, exposed and equipped with an appropriate grill cover if no access is
provided for cleaning.
b. Drain lines shall slope¼" per foot to gravity, shall not exceed 15' in length and shall terminate a
minimum of I" above the floor sink with a legal air gap. Drain lines shall not intersect walkways or door
ways.
c. No condensate drainage of any kind can drain to the mop sink.
d. The entire floor surface must be sloped to the floor drains approximately 1/8 inch per foot or a four feet
diameter depression that slopes 1:50 (approximately¼ inch per foot).
e. Conduits of all types shall be installed within walls as practicable. When otherwise installed, they shall be
mounted or enclosed in a chase so as to facilitate cleaning.
6) Owners and/or operators must pass an approved and accredited Food Safety Certification course. Proof of
successful completion of this course is to be furnished at the final inspection.
7) At the time when the final inspection is requested, the facility shall have all utilities operational and all
refrigeration shall have an ambient air temperature of 38"F or below and shall be equipped with a thermometer
accurate to+/-2'F in the warmest section of the unit. All equipment is to be in place and functional.
8) Seal all cracks, gaps and crevices in counters, cabinets, around metal flashing, sink backsplashes, around pipes
and conduits with silicone sealant.
9) AN AIR BALANCE REPORT IS REQUIRED IF THE FACILITY HAS VENTILATION HOODS.
10) ANY FOOD PROCESSING AREAS MUST BE COMPLETELY ENCLOSED. OPERABLE
WINDOWS, MOVEABLE WALL PANELS, GARAGE ROLL-UP DOORS, OR OTHER MEANS OF
RENDERING FOOD PROCESSING AREAS NOT FULLY ENCLOSED ARE NOT APPROVED.
11) Be advised, applicable jurisdiction requirements that result in changes to approved plans may require
revisions to the Department of Environmental Health plans.
"Environmental and public health through leadership, partnership and science"