Loading...
HomeMy WebLinkAbout2568 STATE ST; ; CB050497; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 04-05-2005 Electrical Permit Permit No: CB050497 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Reference #: 2568 STATE ST CBAD ELEC 2031012800 Status: Lot#: 0 Applied: Entered By: Plan Approved: Issued: Project Title: CASO RES-UPGRADE TO(2)200AMP Inspect Area: 3 PHASE METERS FOR POTTERY KILNS(WORKSHOP =SUITE Applicant: Electric Issue Fee Single Phase per AMP Three Phase per AMP Three Phase 480 Per AMP Remodel/Alteration per AMP Remodel Fee Temporary Service Fee Test Meter Fee Other Electrical Fees Additional Fees TOTAL PERMIT FEES 0 300 0 0 Owner: CABOANAM 1485 LYCOMING ST #302 SAN DIEGO CA 92154 ISSUED 02/16/2005 LSM 04/05/2005 04/05/2005 $10.00 $0.00 $150.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $160.00 Total Fees: $160.00 Total Payments To Date: $0.00 Balance Due: $160.00 5382 04/05/05 0002 01 CGP Inspector: FINAL APPROVAL / Date: £ -IF -.,_.,_.s Clearance: NOTICE: Please take NOTICE that approval of your project illCludes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Ca~sbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any f x in fwhi v rvi I ivn N Tl E imilr hi r whi flimi in rvi I hrwi 02 160-00 FOR OFFICE USE ONLY PERMIT APPLICATION PLAN CHECK No.C/6o-::::,7J<-f£l 1 t CITY OF CARLSBAD BUILDING DEPARTMENT EST. VAL. __________ _ 1635 Fa.,t"aday Ave., Carlsbad, CA 92008 ) 1 PR~T fuft""'fii+ ! !}.; Plan Ck. Deposit ~ Validated By~--~-.,.c....---,c:;;..;c.:_.;;;._ ___ _ Date ,.j)/fa ~ =f-t 'iAddress (include Bldg/Suite #) Business Name (at this address) Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units 3,. APPLiCANT . Fax# 1 7 2..2 3 so-- Address City State/Zip Telephone# City State/Zip Telephone under penalty of perjury one of the following declarations: consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is Expiration Date _______ _ Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred atlon, damages as provided for In Section 3706 of the Labor c e, Inter st and attorney's fees. DATE G i reby affirm that I am exempt from the Contractor's License Law for the following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure Is not intended or offered for sale c. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted _with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): _________________________________________________ _ 5. I will provide some of the work, b I have contracted (hired) the following persons to provide the work indicated (i of work): ____________ -tt----,r,--,,..--~----------------------,-11---+-:::c--------------- PROPERTY OWNER SIGNATURE ---1'¥f<.J£J1U..__..!.=-.c..=....::::::...._______________ DA TE --'-I--''-+-'-<--.,._.__ __ _ • OMPLETE:THIS.SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY . Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site 7 D YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. !8~ CO.NSTRUCTION °LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME ______________ _ LENDER'S ADDRESS ________________________ _ ,9.. AP"llCANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit\' of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued b building Official under t rovisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not co ed within 180 d s fro te of such permit or if the building or work authorized by such permit is suspended or abandoned .J at any time after the work is com ion 106.4.4 Uniform Building Code). .? ~ A APPLICANT'S SIGNATURE -+--J'W "'l---+-;,,of:a,,C.......::_ __ __::::!!ll!!!!l:::----------DATc;,,-, l UNSCHEDULED BUILDING INSPECTION DATE INSPECTOR K /? PERMIT# Cl5' c2>7;:)Y:.'17 PLANCHECK# ___ _ JOB ADDRESS .2 S&cf-: ,$"@ ,.c,.. Q<" -' DESCRIPTION __________________ _ CODE DESCRIPTION ACT COMMENTS ///de_~ J,,,5~...__ r-t---f W><)~ City of Carlsbad Bldg Inspection Request For: 07/06/2005 Permit# CB050497 Inspector Assignment: _!Lj:> Title: CABO RES-UPGRADE TO(2)200AMP Description: 3 PHASE METERS FOR POTTERY KILNS(WORKSHOP =SUITE 100) Type: ELEC Sub Type: Job Address: 2568 STATE ST Suite: 100 Location: OWNER CABO ANA M Owner: CABO ANA M Remarks: Total Time: Lot 0 CD Description Act Comment Phone: 6195183890 Inspector: __ __,_;_2-{,5 Requested By: NA Entered By: CHRISTINE 14 Frame/Steel/Bolting/Welding ~ ------------------- 34 Rough Electric _J.i.f_~~~------~,------------ ____3-} ______ ft ok ~ Me.Lee ;:.?fMQ! !-s£ ~-~ Associated PCRs/CVs Inspection History Date Description Act lnsp Comments ' DATE: 03/31/05 JURISDICTION: Carlsbad PLAN CHECK NO.: 05-0497 EsGil Corporation In q>artnersnip witn government hr (JJuiUing Safety SET:11 PROJECT ADDRESS: 2568 state street ste. 100 PROJECT NAME: UPGRADE ELECTRICAL SERVICE D PLAN REVIEWER D FILE C8] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: C8] Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax#: Mail Telephone Fax In Person □ REMARKS: By: Morteza Beheshti Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 3/24 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 ---.... . .... ·-·-· ···-... EsGil Corporation In <Partnersfiip witfi (jovernment for rJJuifain9 Safety DATE: 03/04/05 JURISDICTION: Carlsbad □A~NT □~ □ PLAN REVIEWER □ FILE PLAN CHECK NO.: 05-0497 SET:I PROJECT ADDRESS: 2568 State st. ste 100 PROJECT NAME: UPGRADE ELECTRICAL SERVICE □ □ □ □ □ ~ □ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: OCEANSIDE ELECTRIC ( :,, H) 302 WISCONSIN AVE. Oceanside, CA 92054 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: (J11--1) '-', H, Telephone#: (760) 722-6880 Date contacted:!, \·1-/-:,5 (by:I'.:.... ) Fax #: Mail ----Telephone....,.. Fax In Person REMARKS: By: Morteza Beheshti Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 2/23 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad 05-0497 03/04/05 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2568 State st. ste 100 DATE PLAN RECEIVED BY ESGIL CORPORATION: 2/23 REVIEWED BY: Morteza Beheshti FOREWORD (PLEASE READ): PLAN CHECK NO.: 05-0497 DATE REVIEW COMPLETED: 03/04/05 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections on the originals and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? □ Yes □ No Carlsbad 05-0497 03/04/05 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 05-0497 PREPARED BY: Morteza Beheshti DATE: 03/04/05 BUILDING ADDRESS: 2568 State st. ste 100 BUILDING OCCUPANCY: NA TYPE OF CONSTRUCTION: NA BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code CB By Ordinance 1994 UBC Building Permit Fee 1994 UBC Plan Check Fee Type of Review: □ Complete Review D Structural Only D Other D Repetitive Fee 3Repeats 0 Hourly 21 Hours• Esgll Plan Review Fee • Based on hourly rate Comments: ELECTRICAL PLAN REVIEW ONLY. ($) $240.001 $102.001 Sheet 1 of 1 macvalue.doc Carlsbad 05-0497 03/04/05 ELECTRICAL CORRECTIONS PLAN REVIEWER: Morteza Beheshti 1. All electrical sheets of the plans are required to be signed by the California licensed engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. Business and Professions Code. • ELECTRICAL (1999 NATIONAL ELECTRICAL CODE) 2. Submit completed plans for a complete review. 3. Submit a completed service and feeder one line diagram for review. NEC 215-5. 4. Show the ampere interrupting capacity (AIC) ratings of the service and sub-service equipment. NEC 110-9 5. Show or note on the plans the method used to limit fault currents to 10,000 amps on branch circuits. NEC 230-208 6. Note on the single line diagram that all service disconnect devices shall be labeled as a "Service Disconnecting Means". NEC 230-?0(b) 7. Please show or identify new loads proposed for the existing equipment. 8. Indicate main service total load demand on the service(s). 9. Please show on the plan the clearance in front of the service(s). NEC 110-26, 230-2. 10. If utilizing a series-rated system, note on plans: "Overcurrent device enclosures will be identified as series-rated and labeled in accordance with NEC 110-22" and "The overcurrent devices shall be AIC rated per manufacturers. labeling of the electrical equipment". 11. Rebar OR ground rods are not acceptable grounding electrodes for commercial applications in the City of Carlsbad. Please describe what the "UFER" ground will be. (footage, conductor material and size, depth in footing.) Note: The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Morteza Beheshti at Esgil Corporation. Thank you.