Loading...
HomeMy WebLinkAbout1351 SPARROW RD; ; CB950074; PermitB U I L D I N G P E R M I T 05/15/95 07:51 Pacre ·1 ot 1 Job Address: 1351 SPARROW RD Suite: Permit Type : SINGLE FAMILY DWLNG -DETACHED Parcel No: 215-640-30-00 Lot#: 33 Valuation : 182,148 Construction Type: VN Occupancy Group: k3/Ml Description: 2087 SF+ : GREYSTONE Reference#: 605 SF GARAG~ PLAN 1 PHASE III CT90-15 Permit No: CB950074 Project No : A9500079 Development No: Status : Applied: Ar,.)r/Issue: Appl/Ownr : GREYSTONE HOMES , INC . 495 EAST RINCON #115 CORONA, CA 9 1 718 909 Entered By: 273-9494 ISSUED 09/14/94 l) 3/15/9 5 DC > CB941011 Plan Check Number Fees Required *** F ~ Collected & Credits Fees : AdJustments: Total Fees . Fee description Building Permit Plan Check Strong Motion Fee Enter Number of EDU' Enter "Y" to Autoce le Enter "Y" to Autoc le Payoff Fee for CFD * BUILDING TOTAL Enter "Y" for Plumbinq Fach Plumbinq Fixtur Each Building Sewer Earh Install/Repair Water Line Each Water Heater and/or ~ent Gas Piping System Each Vacuum Breaker * PLUMBING TOTAL Enter 'Y" for Electric Issue Fee > Single Phase Per AMP > * ELECTRICAL TOTAL Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts/Heat Pumps > Each Install Fireplace > Each Exhaust Fan > A MECHANICAL TOTAL PLDA D > 200 1 1 4 .22 CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 7 .00 15.00 7 .00 7. l10 7.00 7.00 .25 9.00 6.50 6.50 .00 350.00 12,402.14 Ext fee Data 930.00 605,00 18.00 2400.00 3315.00 540.00 4666.14 12474.14 20.00 84.00 15.lJO 7.00 7. 0 O 7.00 14.00 154.00 10.00 50.00 60 .0U 15.00 9.00 6 .50 2D.!JI) 57.00 7 .00 y y y y y L 1875 05/15/95 0001 01 02 C-PRMT 12402-14• CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB950074 FOR 09/18/95 DESCRIPTION: 2087 SF+ 605 SF GARAGE PLAN 1 GREYSTONE PHASE III TYPE: SFD JOB ADDRESS: 1351 SPARROW RD APPLICANT: GREYSTONE HOMES, INC, CONTRACTOR: OWNER: PHONE: PHONE: PHONE: INSPECTOR AREA PY PLANCK# CB941011 OCC GRP R3/Ml CONSTR. TYPE VN STE: LOT: 33 909 273-9494 REMARKS: MW/LON SPECIAL INSTRUCT: INSPECTOR --f~r:H-------- TOTAL TIME: CD 19 29 39 49 LVL DESCRIPTION ACT COMMENTS ST Final structural PL Final Plumbing EL Final Electrical ME Final Mechanical ~------- ------------------------------------------------------ ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 090695 Final Combo PA PY 082895 Final Combo NR PY 072795 Gas/Test/Repairs AP TP 071795 Exterior Lath/Drywall AP PY 070595 Interior Lath/Drywall AP PY 070595 Exterior Lath/Drywall NR PY 062995 Insulation AP PY 062795 Frame/Steel/Bolting/Welding AP PY 062795 Rough/Ducts/Dampers co PY 062795 Rough/Topout AP PY 062795 Rough Electric AP PY 062195 Roof/Reroof AP PY 062195 Shear Panels/HD's AP PY 062095 Roof/Reroof NR PY 062095 Shear Panels/HD's NR PY 052695 Ftg/Foundation/Piers AP PY 052395 Underground/Under Floor NR PY 052295 Underground/Under Floor AP TP FINAL BUILDING INSPECTION ~ DEPT: BUILDING ENGINEERING FIRE PLANNING U/M ~ PLAN CHECK#: CB950074 DATE: 08/28/95 PERMIT#: CB950074 PERMIT TYPE: SFD PROJECT NAME: 2087 SF+ 605 SF GARAGE PLAN 1 GREYSTONE PHASE III ADDRESS: 1351 SPARROW RD LOT# 33 • CONTACT PERSON/PHONE#: RS/JERRY/431-8356 SEWER DIST: WATER DIST: ======================-=====----============================================= ~~~PECTEm11:5< INSPECTED BY: INSPECTED BY: DATE u-/ L" . /./ INSPECTED: 9-rr5/v APPROVED _v DISAPPROVED DATE INSPECTED: DATE INSPECTED: APPROVED DISAPPROVED APPROVED DISAPPROVED =====~=n==============================x=========================•============ COMMENTS: .. BUILDING INSPECTION DEPT: BUILDING PLANNING U/M WATER PLAN CHECK#: CB950 4 PERMIT#: CB950074 PROJECT NAME: 2087 SF+ 605 SF GARAGE PLAN 1 GREYSTONE PHASE III ADDRESS: 1351 SPARROW RD LOT# 33 CONTACT PERSON/PHONE#: RS/JERRY/431-8356 SEWER DIST: WATER DIST: DATE: 08/28/95 PERMIT TYPE: SFD ===============================---=========================================== ;~~PECTEDa,,¢,1: INSPECTED BY: INSPECTED BY: DATE a ,/l_u INSPECTED: 7 -J-r,°5' APPROVED DATE INSPECTED: DATE INSPECTED: APPROVED APPROVED ,_,,,,.,, DISAPPROVED DISAPPROVED DISAPPROVED ~==========================-======-===========~===================T✓========= COMMENTS: DEPT: BUILDING ENGINEERING PLAN CHECK#: CB950074 PERMIT#: CB950074 FIRE PROJECT NAME : 2087 SF+ 605 SF GARAGE PLAN 1 GREYSTONE PHASE III ADDRESS : 1351 SPARROW RD LOT# 33 CONTACT PERSON/PHONE#: RS/JERRY/431-8356 SEWER DIST: WATER DIST: /M WATER DATE: 08/28/95 PERMIT TYPE: SFD ~~~;;;=~~======~:::::::==;~:;~;-:::::: 7 ::A::::~== INSPECTED DATE BY: __________ INSPECTED: ___ APPROVED DISAPPROVED INSPECTED BY: DATE INSPECTED: APPROVED DISAPPROVED -==-=~------==------------=-=-=-=-----=-----------=--------===-=-=-=--------- COMMENTS: DEPT: BUILDING FINA~NG INSPECTION ENGINEERING V PLANNING U/M PLAN CHECK#: CB950074 PERMIT#: CB950074 PROJECT NAME: 2087 SF+ 605 SF GARAGE PLAN 1 GREYSTONE PHASE III ADDRESS: 1351 SPARROW RO LOT# 33 CONTACT PERSON/PHONE#: RS/JERRY/431-8356 SEWER DIST: WATER DIST: WATER DATE: 08/28/95 PERMIT TYPE: SFO =======================================~-~============= ~=============== INSPECTED DATE A BY: f"' · ~~;A INSPECTED: Iv]'✓ APPROVED _ DISAPPROVED _ INSPECTED BY: INSPECTED BY: DATE INSPECTED: DATE INSPECTED: APPROVED DISAPPROVED APPROVED DISAPPROVED =====•===========•========~=z=~========•======••••=•==============s===z====== COMMENTS: