HomeMy WebLinkAbout2742 STATE ST; ; CBCA2020-0009; PermitBuilding Permit Finaled
(City of
Carlsbad
Commercial Associated Permit
Print Date: 10/22/2020
Job Address:
PermitType:
2742 STATE ST, CARLSBAD, CA 92008-1628
BLDG-Associated Permit Commercial Work Class: Addition
Parcel#:
Valuation:
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
2031811900
$2,215,171.88
Project Title: STATE STREET COMMONS
Track#:
Lot#:
Project#: DEV2019-0048
Plan#:
Construction Type:
Orig. Plan Check#: PC2019-0066
Plan Check#:
Permit No: CBCA2020-0009
Status: Closed -Finaled
Applied: 02/10/2020
Issued: 02/24/2020
Finaled Close Out: 05/14/2020
Inspector:
Final Inspection:
MColl
10/22/2020
Description: STATE STREET COMMONS: MODIFY EXISTING 3 STRUCTURES (2742A, 2742B, AND 2745) INTO ONE BUILDING// 19,038 SF
REBUILD/IMPROVEMENTS AND 4,945 NEW OFFICE WITH 5,200 SF PATIO COVERS
Property Owner:
STATE STREET COMMONS, LLC
2659 STATE ST, # 100
CARLSBAD, CA 92008-1627
(619) 840-7721
FEE
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES-outside CFD
SB1473 GREEN BUILDING STATE STANDARDS FEE
SDCWA SYSTEM CAPACITY 2" Displacement
SWPPP INSPECTION FEE TIER 1-Medium BLDG
SWPPP PLAN REVIEW FEE TIER 1-MEDIUM
WATER METER FEE 2" Displacement (P)
WATER SERVICE CONNECTION 2" DISPLACEMENT (P)
WATER TREATMENT CAPACITY 2" Displacement
Total Fees: $67,615.33 Total Payments To Date:
Building Division
$67,615.33 Balance Due:
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
AMOUNT
$5,953.84
$4,167.69
$1,510.00
$175.00
$178.00
$18,134.80
$89.00
$16,963.00
$246.00
$55.00
$378.00
$19,295.00
$470.00
$0.00
Page 1 of 1
Permit Type:
Work Class:
Status:
Scheduled
Date
10/22/2020
BLDG-Associated Permit Commerc Application Date: 02/10/2020
Addition Issue Date:
Closed -Finaled Expiration Date:
IVR Number:
Actual Inspection Type Inspection No.
Start Date
10/22/2020 BLDG-Final Inspection
Checklist Item
141673-2020
COMMENTS
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
02/24/2020
03/29/2021
24753
Inspection
Status
Passed
Thursday, October 22, 2020
Owner: STATE STREET COMMONS, LLC
Subdivision: SEASIDE LANDS
Address: 2742 STATE ST
CARLSBAD, CA 92008-1628
Primary Inspector
Chris Renfro
Reinspection
Passed
Yes
Yes
Yes
Yes
Yes
Inspection
Complete
Page 8 of 8
Permit Type: BLDG-Associated Permit Commerc
Work Class: Addition
Application Date: 02/10/2020 Owner: STATE STREET COMMONS, LLC
Issue Date: 02/24/2020 Subdivision: SEASIDE LANDS
Status:
Scheduled
Date
08/31/2020
09/30/2020
10/13/2020
10/16/2020
10/20/2020
Closed -Finaled Expiration Date: 03/29/2021
IVR Number: 24753
Address: 2742 STATE ST
CARLSBAD, CA 92008-1628
Actual Inspection Type
Start Date
08/31/2020 BLDG-17 Interior
Lath/Drywall
Checklist Item
Inspection No.
136995-2020
COMMENTS
Inspection
Status
Primary Inspector
Partlal Pass Paul Burnette
BLDG-Building Deficiency
BLDG-24 Rough/Topout 136997-2020 Partlal Pass Paul Burnette
Checklist Item
BLDG-Building Deficiency
COMMENTS
Underground waste line for grease
interceptor connection. And 4" laterals to
main. OK to backfill
09/30/2020 BLDG-23 139662-2020 Passed Chris Renfro
Gas/Test/Repairs
Checklist Item COMMENTS
BLDG-Building Deficiency
10/13/2020 BLDG-Fire Final
Checklist Item
140707-2020
COMMENTS
Failed Adalmlra Maldonado
FIRE-Building Final 10/1312020
1. Provide access to fire extinguisher
south side
2. Label fire riser room 2" 1/2" stroke on
door
3. Label backflow with address sign,
provide lock and breakaway lock
4. Provide sign in elevator room "no
combustible storage
10/1612020 BLDG-Fire Final
Checklist Item
141227-2020
COMMENTS
Passed Adalmlra Maldonado
FIRE-Building Final 10/13/2020
1. Provide access to fire extinguisher
south side
2. Label fire riser room 2" 1/2" stroke on
door
3. Label backflow with address sign,
provide lock and breakaway lock
4. Provide sign in elevator room "no
combustible storage
10/20/2020 BLDG-Final Inspection
Checklist item
141325-2020
COMMENTS
Partial Pass Chris Renfro
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Partial pass on Final Inspection, handrails
on exterior ramps pending.
Reinspection Inspection
Relnspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Complete
Passed
Yes
Relnspectlon Incomplete
Passed
No
Complete
Passed
Yes
Reinspectlon Incomplete
Passed
No
Yes
Yes
Yes
Yes
Thursday, October 22, 2020 Page 7 of 8
,-" "'"*•*""'~ , -i':!~"0*'.;--',*v•j yxry; ::§:Jp~ ,tfjj::§-i5*",' f0 n~ *•::-:
' ' PERMIT lNSPECTlON"'"etScltORY fcitia{CJII::A2120.:ooo,t:+;;f~~ 0
£'"
Permit Type:
Work Class:
Status:
Scheduled
Date
08/07/2020
08/14/2020
08/18/2020
08/20/2020
BLDG-Associated Permit Commerc Application Date: 02/10/2020 Owner: STATE STREET COMMONS, LLC
Addition Issue Date: 02/24/2020 Subdivision: SEASIDE LANDS
Closed -Finaled Expiration Date: 03/29/2021 Address: 27 42 STATE ST
IVR Number: 24753 CARLSBAD, CA 92008-1628
Actual Inspection Type Inspection No. Inspection Primary Inspector
Start Date Status
Checklist Item
BLDG-Building Deficiency
BLDG·14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG•44
Rough-Ducts-Dampers
COMMENTS
Partial pass on driveway ceiling, OK to
cover pending fire sprinkler
08/07/2020 BLDG-11 135044-2020 Partial Pass Chris Renfro
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item
BLDG-Building Deficiency
COMMENTS
Partial pass on CMU foundation wall for
trash enclosure, & (3) light pole bases, ok
to pour
08/14/2020 BLDG-18 Exterior
Lath/Drywall
135866-2020 Partial Pass Tony Alvarado
Checklist Item COMMENTS
BLDG-Building Deficiency April 14, 2020:
1. Building A, Exterior stucco lath areas-
(only) -approved.
BLDG-83 Roof Sheatlng, 135865-2020
Exterior Shear (13, 15)
Checklist Item COMMENTS
BLDG-13 Shear Panels-HD (ok April 14, 2020:
Partial Pass Tony Alvarado
to wrap) 1. Chimney-fireplace (appliance) area only,
exterior shearwall nailing-approved.
08/18/2020 BLDG-18 Exterior
Lath/Drywall
135928-2020 Partial Pass Chris Renfro
Checklist Item COMMENTS
BLDG-Building Deficiency Partial pass
08/20/2020 BLDG-18 Exterior
Lath/Drywall
136297-2020 Partial Pass Chris Renfro
Checklist Item COMMENTS
BLDG-Building Deficiency Partial pass on building "c"
BLDG-34 Rough
Electrical
136232-2020 Partial Pass Chris Renfro
Checklist Item
BLDG-Building Deficiency
COMMENTS
Rough electrical inspection on. Front high
ceiling entryway.
Reinspection
Passed
No
Yes
Yes
Yes
Yes
Inspection
Relnspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Relnspectlon Incomplete
Passed
Yes
Reinspectlon Incomplete
Passed
Yes
Relnspection Incomplete
Passed
Yes
Thursday, October 22, 2020 Page 6 of 8
Permit Type:
Work Class:
Status:
Scheduled
Date
07/13/2020
07/20/2020
07/22/2020
07/27/2020
08/04/2020
BLDG-Associated Permit Commerc Application Date: 02/10/2020 Owner: STATE STREET COMMONS, LLC
Addition Issue Date: 02/24/2020 Subdivision: SEASIDE LANDS
Closed -Finaled Expiration Date: 03/29/2021 Address: 2742 STATE ST
IVR Number: 24753 CARLSBAD, CA 92008-1628
Actual
Start Date
Inspection Type
BLDG-15 Roof/ReRoof
(Patio)
Checklist Item
Inspection No, Inspection Primary Inspector
Status
132150-2020 Partial Pass Chris Renfro
COMMENTS
BLDG-Building Deficiency Partial pass roof nailing on Building "A", OK
to build crickets
07/13/2020 BLDG-11
F o u ndatlo n/Ftg/P lers
(Rebar)
Checklist Item
132565-2020 Partial Pass Chris Renfro
COMMENTS
BLDG-Building Deficiency Partial pass. See plans for areas
inspected. CMU Wall FTG for Building C
front patio
07/20/2020 BLDG-13 Shear
Panels/HD (ok to wrap)
Checklist Item
133374-2020 Partial Pass Chris Renfro
COMMENTS
BLDG-Building Deficiency Shear panel nailing on building C
BLDG-34 Rough
Electrical
Checklist Item
133252-2020
COMMENTS
Failed Chris Renfro
BLDG-Building Deficiency Not ready
07122/2020 BLDG-11
Foundation/Ftg/Plers
(Rebar)
Checklist Item
133552-2020 Failed Chris Renfro
COMMENTS
BLDG-Building Deficiency Not ready
BLDG-34 Rough
Electrlcal
Checklist Item
133553-2020 Partial Pass Chris Renfro
COMMENTS
BLDG-Building Deficiency Rough electrical inspection on main panel
and switchgear. Grounding and bonding
verified.
07/27/2020 BLDG-11
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item
133835-2020 Partial Pass Chris Renfro
COMMENTS
BLDG-Building Deficiency Partial pass on planter walls front areas.
OK to pour
08/04/2020 BLOG-84 Rough
Combo(14,24,34,44)
134556-2020 Partial Pass Chris Renfro
Reinspection Inspection
Relnspectlon Incomplete
Passed
Yes
Reinspectlon Incomplete
Passed
Yes
Re Inspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
No
Re inspection Incomplete
Passed
No
Relnspectlon Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Reinspectlon Incomplete
Thursday, October 22, 2020 Page 5 of 8
Permit Type:
Work Class:
Status:
Scheduled
Date
05/29/2020
06/04/2020
06/12/2020
06/30/2020
07/07/2020
BLDG-Associated Permit Commerc Application Date: 02/10/2020 Owner: STATE STREET COMMONS, LLC
Addition Issue Date: 02/24/2020 Subdivision: SEASIDE LANDS
Closed -Finaled Expiration Date: 03/29/2021 Address: 27 42 STATE ST
IVR Number: 24753 CARLSBAD, CA 92008-1628
Actual Inspection Type Inspection No. Inspection Primary Inspector
Start Date Status
05/28/2020
06/04/2020
06/12/2020
BLDG-11 128739-2020 Partial Pass Chris Renfro
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item COMMENTS
BLDG-Building Deficiency Partial pass. See plans for areas
inspected. Grade beam footing, (2) F2
footings and slab on grade for electrical
room.
BLDG-11 129411-2020 Partial Pass Chris Renfro
Foundatlon/Ftg/Piers
(Rebar)
Checklist Item COMMENTS
BLDG-Building Deficiency Partial pass. See plans for areas
inspected. Grade beam footing, CMU Walt
FTG
BLDG-14 130063-2020 Partial Pass Chris Renfro
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item COMMENTS
BLDG-Building Deficiency Partial pass on elevator shaft equipment
BLDG-16 lnsulatlon
Checklist Item
room. Insulation and Dens -glass OK. OK to
tape and mud
130064-2020
COMMENTS
Partlal Pass Chris Renfro
BLDG-Building Deficiency Partial pass elevator equipment room and
shaft
06/30/2020 BLDG-14 131416-2020 Partial Pass Chris Renfro
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item
BLDG-Building Deficiency
COMMENTS
2nd Story deck nail complete.
BLDG-15 Roof/ReRoof
(Patio)
131568-2020 Partial Pass Chris Renfro
Checklist Item COMMENTS
BLDG-Building Deficiency Partial pass roof nailing on Building "C"
07/07/2020 BLDG-14 132006-2020 Partial Pass Chris Renfro
Frame/Steel/Bolting/We
!ding (Decks)
Checklist Item
BLDG-Building Deficiency
COMMENTS
Reinspection
Reinspectlon
Passed
Yes
Relnspectlon
Passed
Yes
Reinspection
Passed
Yes
Re Inspection
Passed
Yes
Re inspection
Passed
Yes
Reinspectlon
Passed
Yes
Reinspection
Passed
Yes
Inspection
Incomplete
Incomplete
Incomplete
Incomplete
Incomplete
Incomplete
Incomplete
Thursday, October 22, 2020 Page 4 of 8
------------------
Permit Type: BLDG-Associated Permit Commerc
Work Class: Addition
Application Date: 02/10/2020 Owner: STATE STREET COMMONS, LLC
Status:
Scheduled
Date
05/11/2020
0511412020
05/2012020
05/21/2020
05/26/2020
Closed -Finaled
Issue Date: 02/24/2020 Subdivision: SEASIDE LANDS
Expiration Date: 03/29/2021 Address: 2742 STATE ST
CARLSBAD, CA 92008-1628 IVR Number: 24753
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
BLDG-34 Rough
Electrical
Checklist Item
126656-2020 Partial Pass Chris Renfro
COMMENTS
BLDG-Building Deficiency Underground conduit from building a to
building C
05/1112020 BLDG-34 Rough
Electrical
Checklist Item
127102-2020 Partial Pass Chris Renfro
COMMENTS
BLDG-Building Deficiency Underground conduit from building A and
1 0' ground rod at electrical room
05/1412020 BLDG-11
F o u ndatlon/Ftg/P lers
(Rebar)
Checklist Item
127488-2020 Partial Pass Chris Renfro
COMMENTS
BLDG-Building Deficiency See plan for highlighted areas, Partial pass
on ftgs for Bldg CMU wall on rear corner
BLDG-24 Rough/Topout 127487-2020 Partial Pass Chris Renfro
Checklist Item COMMENTS
BLDG-Building Deficiency Underground waste line for grease
interceptor connection. And 4" laterals to
main. OK to backfill
05/2012020 BLDG-21
Underground/U nderflo
or Plumbing
Checklist Item
128095-2020 Partial Pass Chris Renfro
COMMENTS
BLDG-Building Deficiency Partial pass on Building "A" underground
waste and grease interceptor line tie-in
05/21/2020 BLDG-66 Grout
Checklist Item
128182-2020
COMMENTS
Partial Pass Chris Renfro
BLDG-Building Deficiency Partial pass first Lift. OK to grout
05/2612020 BLDG-11
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item
128424-2020
COMMENTS
BLDG-Building Deficiency
BLDG-66 Grout
Checklist Item
128425-2020
COMMENTS
Partlal Pass Chris Renfro
Partlal Pass Chris Renfro
BLDG-Building Deficiency Partial pass second lift. OK the grout
Re Inspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Re inspection Incomplete
Passed
Yes
Reinspectlon Incomplete
Passed
Yes
Reinspectlon Incomplete
Passed
Yes
Re inspection Incomplete
Passed
Yes
Relnspection Incomplete
Passed
Yes
Relnspection Incomplete
Passed
Yes
Thursday, October 22, 2020 Page 3 of 8
-----------···-·-···
~ "< ~ ' ' ~ F ;;' 7" £_'" " ~ ~ ~ =~ 5
~-~~-; ~~';;°'~:"
PERMIT INSPECTION HISTORY for (CBCA2.O2O-OOO9}: .. _ •.
Permit Type: BLDG-Associated Permit Commerc Application Date: 02/10/2020 Owner: STATE STREET COMMONS, LLC
Work Class: Addition Issue Date: 02/24/2020 Subdivision: SEASIDE LANDS
Status: Closed -Finaled Expiration Date: 03/29/2021 Address: 2742 STATE ST
IVR Number: 24753 CARLSBAD, CA 92008-1628
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
BLDG-24 Rough/Topout 124970-2020 Falled Chris Renfro Relnspectlon Incomplete
Checklist Item COMMENTS Passed
BLDG•Building Deficiency Not ready No
04121/2020 04/2112020 BLDG-11 125134-2020 Partial Pass Chris Renfro Relnspectlon Incomplete
04/23/2020
05/05/2020
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item
BLDG•Building Deficiency
COMMENTS
Partial pass on ftgs for Bldg "C", Front right
side pier flg, ok to pour
BLDG-24 Rough/Topout 125133-2020 Partial Pass Chris Renfro
Checklist Item
BLDG·Building Deficiency
COMMENTS
Underground waste line for grease
interceptor connection. OK to backfill
04/23/2020 BLDG-11 125442-2020 Partial Pass Chris Renfro
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item
BLDG-Building Deficiency
COMMENTS
See plan for highlighted areas, Partial pass
on ttgs for Bldg "C"; driveway pier figs,
05/05/2020 BLDG-11 126475-2020 Partial Pass Chris Renfro
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item
BLDG-Building Deficiency
COMMENTS
See plan for highlighted areas, Partial pass
on ftgs for Bldg "A" rear area electrical
room only. Need UFER or ground wire
installed.
BLDG-21
Underground/Underflo
or Plumbing
126640-2020 Partial Pass Chris Renfro
Checklist Item
BLDG-Building Deficiency
COMMENTS
Partial pass on 4 inch waste line to grease
interceptor and 3 inch vent pipe. OK to
backfill
05/06/2020 05/0612020 BLDG-11 126655-2020 Partial Pass Chris Renfro
Thursday, October 22, 2020
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item
BLDG-Building Deficiency
COMMENTS
See plan for highlighted areas, Partial pass
on ftgs for Bldg "A" (4) 12 ftgs and (2) 12.5
ftgs. UFER Verified matches plans.
Passed
Yes
Reinspectlon Incomplete
Passed
Yes
Reinspectlon Incomplete
Passed
Yes
Relnspection Incomplete
Passed
Yes
Reinspectlon Incomplete
Passed
Yes
Reinspectlon Incomplete
Passed
Yes
Page 2 of 8
Building Permit Inspection History Finaled
{city of
Carlsbad
Permit Type: BLDG-Associated Permit Commerc
Work Class: Addition
Application Date: 02/10/2020 Owner: STATE STREET COMMONS, LLC
Status:
Scheduled
Date
03/2512020
03/31/2020
04/01/2020
04102/2020
Issue Date: 02/24/2020 Subdivision: SEASIDE LANDS
Closed -Finaled Expiration Date: 03/29/2021
IVR Number: 24753
Address: 2742 STATE ST
CARLSBAD, CA 92008-1628
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector
Status
05/21/2020 BLDG-66 Grout
Checklist Item
128344-2020
COMMENTS
Cancelled Chris Renfro
BLDG-Building Deficiency Partial pass first Lift. OK to grout
03/25/2020 BLDG-22 Sewer/Water
Service
123322-2020 Partial Pass Michael Collins
Checklist Item
BLDG-Building Deficiency
COMMENTS
Prelim 6" sewer POC within rear easement,
see card for additional notes.
03/31/2020 BLDG-24 Rough/Topout 123615-2020 Partlal Pass Chris Renfro
Checklist Item
BLDG-Building Deficiency
COMMENTS
Underground plumbing for 6 inch line and 4
inch branch lines. Missing one branch line
per plans.
04/01/2020 BLDG-24 Rough/Topout 123827-2020 Partial Pass Chris Renfro
Checklist Item
BLDG-Building Deficiency
COMMENTS
Underground plumbing for 6 inch line and 4
inch branch lines. Missing one branch line
per plans.
04102/2020 BLDG-11 123902-2020 Partial Pass Chris Renfro
Foundation/Ftg/Plers
(Rebar)
Checklist Item
BLDG-Building Deficiency
COMMENTS
Partial pass on ftgs for Bldg "B", See Plans
highlighted
Reinspection Inspection
Reinspectlon Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Relnspectlon Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
04/03/2020 04/03/2020 BLDG-11 124063-2020 Partial Pass Chris Renfro Re inspection Incomplete
F OU n dation/Ftg/P lers
(Rebar)
Checklist Item
BLDG-Building Deficiency
COMMENTS
Partial pass on remaining ftgs for Bldg "B",
See Plans highlighted
04117/2020 04/17/2020 BLDG-11 124969-2020 Partlal Pass Chris Renfro
Thursday, October 22, 2020
Foundatlon/Ftg/Plers
(Robar)
Checklist Item
BLDG-Buildlng Deficiency
COMMENTS
Partial pass on ftgs for Bldg "C", See Plans
highlighted
Passed
Yes
Reinspection Incomplete
Passed
Yes
Page 1 of 8
.... j ~ ..
City of Carlsbad
JUL 2 0 2020
Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Surveying
BUILDING DIVISION
INSPECTION REPORT PAGE __ _ OF
CTE JOB NO. 10-15483T
PROJECT NAME _S_ta_te_St_re_e_t _______ _
ADDRESS 2742 State Street
Carlsbad, 92008
ARCHITECT ....:G:c......::.C..:..ol...::e..:..m..:..a..:..n _________ _
ENGINEER ....:B_r...:.;la_n...::Q;.:.u..:..al--'ls _________ _
CONTRACTOR C2SD, BTC Framing.
OTHER Ell (858)964-8570
INSPECTION DATE -'-0_7/_2_0/_2_0 ________ _
PLAN FILE/OTHER
BLDG. PERMIT/OTHER CBCA2020-0009
REPORT NO.
INSPECTION MATERIAL IDENTIFICATION
0 CONCRETE CONC. MIX NO. & lb/in2
0 REINF. STEEL GROUT MIX NO. & lb/ln2
0 MASONRY MORT AR TYPE & lb/ln2
0 P.T. CONCRETE REINF. STEEL GR./SIZE
0 FIELD WELDING STRUCTURAL STEEL
0 SHOP WELDING HIGH-STRENGTH SOLT
0 BATCH PLANT
EXP. ANCHOR
MASONRY BLOCK
OTHER D
~ OTHER Shear-walls
MATERIAL SAMPLING
0 CONCRETE O MORTAR O GROUT O FIREPROOFING O MASONRY BLOCK
0 REINFORCING STEEL O STRUCTURAL STEEL O BOLTS O OTHER
INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
PLEASE NOTE ANY RE-INSPECTION, TESTING OR OTHER PROJECT ISSUES.
Inspection and observation continues for:
Building 2. All Shearwalls, Stair Case and Roofing Completed, Verified 1/2" Structural Stamped Sheathing secured in place with
Approved TYP 1" Zinc #8 Strong Point self drilling screws, Sill anchors and Holdowns, TYP Walls Schedule, 3/12, 4/12, 6/12, Straps,
clips in place per approved drawings. Very clean work.
Work continues at Building 3, approx 85% completed,
Haxton Masonry, Delivery commenced for CMU Walls, verified Aeinforcment secured in place, #5 verts @16" OC, double jamb bars at
all corners, Specmix Type S 1800 psi mortar, foundations was blown with compressed air removing all debris, Mason has a copy of the
wall decorative pattern and Placement scheduled.
approved drawing,
Report emailed to eli @c2sd.com
Certification of Compliance: All work, unless oth
PRINTED NAME Desmond King.
CERTIFICATION NO. San Diego #1169 ---.:~---------
1441 Montiel Road, Suite 115 I Escondido, CA 92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net
-·~
RECORD CQP~ity of Carlsbad
Construction Testing & Engineering, Inc. JUL 2 0 2020
Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil En~ui'Lo1,~e;e~v1s10N
INSPECTION REPORT
PROJECT NAME _S_ta_te_S_tre_e_t _______ _
ADDRESS 2742 State Street
Carlsbad, 92008
ARCHITECT ...;G:......:..C.:...ol..::.em~an"-----------
ENGINEER _B_ri_a_n _Q_u_al_ls _________ _
CONTRACTOR C2SD, BTC Framing.
OTHER Ell (858)964-8570
INSPECTION DATE ...;;0_7/ __ 1_0/_2_0 ________ _
PLAN FILE/OTHER
INSPECTION
D CONCRETE
D REINF. STEEL
D MASONRY
D P.T. CONCRETE
D FIELD WELDING
D SHOP WELDING
D BATCH PLANT
D EXP. ANCHOR
PAGE OF
CTE JOB NO. 10-15483T
REPORT NO.
MATERIAL IDENTIFICATION
CONG, MIX NO. & lb/in2
GROUT MIX NO. & lb/ln2
MORT AR TYPE & lb/ln2
REINF. STEEL GR/SIZE
STRUCTURAL STEEL
HIGH-STRENGTH BOLT
MASONRY BLOCK
OTHER
BLDG. PERMIT/OTHER CBCA2020-0009 ~ OTHER Simpsons XP, Shearwalls
MATERIAL SAMPLING
0 CONCRETE O MORTAR O GROUT O FIREPROOFING O MASONRY BLOCK
0 REINFORCING STEEL O STRUCTURAL STEEL O BOLTS O OTHER
INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
PLEASE NOTE ANY RE-INSPECTION TESTING, OR OTHER PROJECT ISSUES.
Inspection and observation continues for:
Building 1 Shearwalls Completed, Verified 1/2" Structural Stamped Sheathing secured in place with Approved TYP 1" Zinc #8 Strong
Point self drilling screws, Sill anchors and Holdowns, TYP Walls Schedule, 3/12, 4/12, 6/12, Straps, clips in place per approved drawings.
Work continues at Building 2 and 3, approx 85% completed,
Roof Nailing Completed All buildings, 1,2 and 3. Structural Stamped Sheathing secured in place, All nails driven flush/ staggered into
framing, (8d: 4 and 6@12"), Sheathing Staggared and perpendicular to supports, expansion joints approx 1 /8" at all edges in place.
Verified strap, clips per plan. very clean work.
Building 3. CMU wall Ftgs, verified Reinforcment secured in place, (5)#5 Cont Bottom, #5 verts @16" OC, double Jamb bars at all
corners, #4 90' dowels@12" OC, note: 3" dobies being placed for clearance and excess dirt / debris will be removed prior to concrete
placement, scheduled for 7 /14/20 TBD
approved drawing,
Report emailed to eli@c2sd.com
Certification of Compliance: All work, unless oth
PRINTED NAME Desmond King.
CERTIFICATION NO. San Diego #1169 __ ......;; _________ _
1441 Montiel Road, Suite 115 I Escondido, CA 92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net
City of Carlsbad
Construction Testing & Engineering, Inc. MAY 2 7 2020
Inspection I Testing I Geotechnlcal I Envlronmental & Construction Engineerln~LJif~'IDI~,~
INSPECTION REPORT
RECORD COPY
PROJECTNAME _S_ta_te_S_t_re_e_t _______ _
ADDRESS 2742 State Street
Carlsbad, 92008
ARCHITECT _G_Co.:..:l.:..:em--"--an _________ _
ENGINEER _B_ri_a_n _Oc_u_al_ls _________ _
CONTRACTOR _C_2_S_D __________ _
OTHER Ell (858)964-8570
INSPECTION DATE ...::0..:.5/:..::2..:.6/:..::2..::...0 ________ _
PLAN FILE/OTHER
BLDG. PERMIT/OTHER CBCA2020-0009
INSPECTION
□ CONCRETE
□ REINF. STEEL
□ MASONRY
□ P.T. CONCRETE
□ FIELD WELDING
□ SHOP WELDING
□ BATCH PLANT
□ EXP. ANCHOR
□ OTHER
MATERIAL SAMPLING
PAGE ___ OF
CTE JOB NO. 10-15483T
REPORT NO.
MATERIAL IDENTIFICATION
CONC. MIX NO. & lb/in2
GROUT MIX NO. & lb/in2 Astm A615/G60
MORTAR TYPE & lb/in2
REINF. STEEL GR/SIZE
STRUCTURAL STEEL
HIGH-STRENGTH BOLT
MASONRY BLOCK
OTHER
0 CONCRETE 0 MORTAR ~ GROUT 0 FIREPROOFING O MASONRY BLOCK
0 REINFORCING STEEL 0 STRUCTURALSTEEL 0 BOLTS O OTHER
INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER PROJECT ISSUES.
ln~pection and observation continues for CMU block placement Building C grid L thru K@13.
HAXTON Masonry, TYP 3/8" joints there after, struck tight and conceived, Specmix Type S, 1800psi on site mortar In use.
Second Lift to full height (24'0")
with clean-outs at 16"OC, TYP #S's. Verts @16" OC, Horiz@24" OC, 90'hooks at double jamb bars.Cleanuouts vacuumed and closed.
Superior Mix #67-123, 3000psl, exceeds required 2500psi. Concrete was pumped I today debris free cells, mechanically vibrated, approx
2" Keyway and Verts In place for Final Lift. (27'6")
Ticket#. 196528. Air. 63' Temp. 75'@50 minsConcrete ticket attached
Block placement continues with Grout Scheduled for Final Lift Wednesday 2/27/20 @930am
approved drawing, S2,
Report emailed to eli@c2sd.com
Certification of Compliance: All work, unless oth
PRINTED NAME ...:D:..:e.:::sm.:.:.o:::.n.::d~K.::.:in~g~. -~=1-::::::::::. ___ _
CERTIFICATION NO. San Diego #1169 --~----------
1441 Montiel Road, Suite 115 I Escondido, CA 92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net
Construction Testing & Engineering, Inc.
Inspection I Testing I Geotechnlcal I En~ronmenlal & Construction Engineering I CMI Engineering I Surveying
REPORT OF COMPRESSION TESTING
PROJECT: State Street Commons
-----------------
PROJECT ADDRESS: 2742 State Street, Carlsbad
CONTRACTOR: C2SD
SUBCONTRACTOF ________________ _
SUPPLIER: Superior
MIX DESCRIPTION: 3000, exceeds required 2500
MIX NUMBER: 67-123 ''-"--------------------
SLUMP: 6" +
TYPE CEMENT: ______ WATER ADDED: gal.
CONCRETE TEMP: 73 AMB. TEMP: 68
PROJECT NO.: 10-15483T
ARCHITECT:
ENGINEER: Brian Qualls
BUILDING PERMIT NO.: CBCA2020-0009
PLACEMENT DATE: 05·26·20 ----------
DATE REC'D IN LAB:
TICKET NUMBER: _________ _
TRUCK NUMBER: -----------
TIME IN MIXER: 54 MINUTES
ADMIXTURE: 1/2 bag Grout aid
TEST SCHEDLUE: ________________ AIR CONTENT: __________ _
LOCATION OF PLACEMENT: Building C, Second Lift, L thru H@13
REQUIRED STRENGTH (f c): 2500 PSl@28 DAYS DESIGN STRENGTH: 2500 PSI -------
FIELD UNIT WEIGHT: ______ pcf DRY UNIT WEIGHT: pcf
SAMPLES MADE BY: Desmond King SET NUMBER: ----LOAD: ____ _
LABORATORY COMPRESSION DATA
AGE LAB NO. DATE TESTED DIMENSIONS TEST AREA MAX LOAD COMPRESSIVE FRACTURE
(in.) (in.2) (lbf.) STRENGTH (psi) TYPE
---
DAYS A --
DAYS B
DAYS C -
DAYS D ---
DAYS E --.. --
DAYS F --~ --
DAYS G
Notes: Samples at Supers office
Construction Testing & Engineering, Inc.
City of Carlsbad
MAY 2 7 2020
Inspection I Testing I Geotechnlcal I Environmental & Construction Engineering I Civil E'\!l'-"lllU>l~·VISION
INSPECTION REPORT
RECORD COPY
PROJECT NAME State Street -=~----------
ADDRESS 2742 State Street
Carlsbad, 92008
INSPECTION
□ CONCRETE
0 REINF. STEEL
PAGE ___ OF
GTE JOB NO. 10-15483T
REPORT NO.
MATERIAL IDENTIFICATION
CONG. MIX NO. & lb/in2
GROUT MIX NO. & lb/in2 Astm A615/G60
ARCHITECT _::G::_C.::O:::l.::em=anc_ _________ _ 0 MASONRY MORTAR TYPE & lb/in2
ENGINEER Brian Qualls '-----'-----==----------0 P.T. CONCRETE REINF. STEEL GR/SIZE
CONT RAC TOR -=C~2~S~D __________ _ □ FIELD WELDING STRUCTURAL STEEL
OTHER Ell (858)964-8570 0 SHOP WELDING HIGH-STRENGTH BOLT
INSPECTION DATE .:::0::::Si.::2.:.:1I.::2.::0 ________ _
PLAN FILE/OTHER
BLDG. PERMIT/OTHER
0 BATCH PLANT
□
I;,]
EXP.ANCHOR
MASONRY BLOCK
OTHER
CBCA2020-0009 OTHER Simpsons XP
MATERIAL SAMPLING
□ CONCRETE O MORTAR ~ GROUT □ FIREPROOFING □ MASONRY BLOCK
□ REINFORCING STEEL □ STRUCTURAL STEEL □ BOLTS □ OTHER
INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER PROJECT ISSUES.
Inspection and observation continues for CMU block placement Building C grid L thru K@13.
HAXTON Masonry, TYP 3/8" joints there after, struck tight and conceived, Specmix Type S, 1800psi on site mortar in use.
First Lift to full height (12'0") with clean-outs at 16"OC, TYP #S's. Verts @16" OC, Horiz@24" OC , 90'hooks at double jamb bars.
Cleanuouts vacuumed and closed. Passed city inspection.
Superior Mix #67-123, 3000psi, exceeds required 2500psi. Concrete was pumped I today debris free cells, mechanically vibrated, approx
2" Keyway and Verts in place for Second Lift.
-ncket#. 196416 Air. 68' Temp. 73'@54 minsConcrete ticket attached
Block placement continues with Grout Scheduled for Second Lift Tuesady 5/26/20 TBD
Epoxy #5 Dowels, horiz@24"OC into existing wall to full height of 27'0"
3/411 Dia holes with 5.5" embedment, all holes blown out with compressed air, brushed and blow again.
Simpsons XP, batch# N1000036522, exp 7/21/21. Completed per ICC/ ESR 2508
approved drawing, S2,
Report emailed to eli@c2sd.com
PRINTED NAME Desmond King.
CERTIFICATION NO. San Diego #1169 -----"'--------------
1441 Montiel Road, Suite 115 I Escondido, CA 92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-lnc.net
Construction Testing & Engineering, Inc.
Inspection I Testing I Geotechnlcal I Environmental & Construction Englneenng I CMI Engineering I Surveying
REPORT OF COMPRESSION TESTING
PROJECT: State Street Commons -----------
PROJECT ADDRESS: 2742 State Street, Carlsbad
----------
CONTRACTOR: C2SD
SUBCONTRACTOF _________ _
SAMPLE DATA
SUPPLIER: Superior
MIX DESCRIPTION: 3000, exceeds required 2500
MIX NUMBER: 67-123 '-"--------------------
SLUMP: 6" +
TYPE CEMENT: ______ WATER ADDED: gal.
CONCRETE TEMP: 73 AMS. TEMP: 68
PROJECT NO.: 10-15483T
ARCHITECT:
ENGINEER: Brian Qualls
BUILDING PERMIT NO.: CBCA2020-0009
PLACEMENT DATE: 05-21-20 ----------
DATE REC'D IN LAB: ________ _
TICKET NUMBER: _________ _
TRUCK NUMBER: _________ _
TIME IN MIXER: 54 MINUTES
ADMIXTURE: 1/2 bag Grout aid
TEST SCHEDLUE: ________________ AIR CONTENT: __________ _
LOCATION OF PLACEMENT: Building C, first Lift, L thru H@13 --------------------------------
REQUIRED STRENGTH (f c): 2500 PSl@28 DAYS DESIGN STRENGTH: _2_50_0 _____ PSI
FIELD UNIT WEIGHT: ______ pct DRY UNIT WEIGHT: _______ pct
SAMPLES MADE BY: Desmond King SET NUMBER: ___ _ LOAD: ____ _
LABORATORY COMPRESSION DATA
AGE LAB NO. DATE TESTED DIMENSIONS TEST AREA MAX LOAD COMPRESSIVE FRACTURE
(in.) (in.') (lbf.) STRENGTH (psi) TYPE
DAYS A
' -DAYS B ----
DAYS C
DAYS D
DAYS E -
1----. DAYS F --
DAYS G
-
Notes: Samples at Supers office
4[atyof
Carlsbad
form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior
lllulng a building pennit. The City wlll not Issue any building permit without a completed school fee form.
DEV2019-00481 STATE STREET COMMONS
Re•ldentJal Square Feet:
New/Additions: -----------Second Dwelling Unit. -----------Comm e rc I a I Square Feet:
New/Additions: _,4,"'9-"45"---------------
Clty Certification: City of Cambad Buildillll Division Date: 02/10/2020
San Dl~utto Union '1.S. 0.,_tT\ct
684 R,equeza Dr
Encinitas, CA 92024
Phone: {760) 753-6491 Ext 5514
(By Appt. Only)
• San Marcos Unified Sch. District
255 Pico Ave Ste. 100
San Marcos, CA 92069
Phone. (760) 290-2649
Contact Katherine Marcelja
(By Appl.only)
SCHOOL DISTRICT SCHOOL FEE CERTIFICATION
(To be completed by the school district(s))
THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS
FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED.
The undersigned, being duly authorized by the applicable School District, certifies that the developer, bullder,
or owner has satisfied the obllgatlon for school facJllties. This Is to certify that the applicant listed on 1>a9e 1.
has paid all amounts or completed other applfcabfe school mitigation determined by the School Di.strict. 1'he
City may Issue bulldlng permits for this project.
Signature of Authorized School District Officiai:J)f . ~~ O/v-0duPJ {~~
Title: ~~t Date: c9-/J~/~0
Name of School District: CARLSBAD UNIFIED SCHOOL DISTRICT Phone: ']IPQ-~/--CJfD7)
6225 EL CAMINO REAi.
Community & Economita6~09Bullding Division
1635 Faraday Avenue I Carlsbad, CA 92008 I 760-602-2719 I 760-602-8558 tax I bui1ding@carlsbadca.gov