Loading...
HomeMy WebLinkAbout2742 STATE ST; A; PC2019-0066; PermitPERMIT REPORT Print Date: 07/14/2021 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms; Bathrooms: 2742 STATE ST, # A, BLDG-Plan Check 2031811900 $0.00 Project Title: STATE STREET COMMONS Plan Check Permit CARLSBAD, CA 92008-1628 Work Class: Track#: Lot#: Project#: Plan#: Construction Type: Orig. Plan Check #: Plan Check#: Commercial DEV2019-0048 itc· · -f '-1tyo Carlsbad Permit No: PC2019-0066 Status: Closed -Finaled Applied: 10/01/2019 Issued: 02/24/2020 Fina led Close Out: 07/14/2021 Inspector: Final Inspection: Description: STATE STREET COMMONS: MODIFY EXISTING 3 STRUCTURES (2742A, 2742B, AND 2745) INTO ONE BUILDING// 19,038 SF REBUILD/IMPROVEMENTS AND 4,945 NEW OFFICE WITH 5,200 SF PATIO COVERS FEE FIRE A-2 & A-3 Occupancies -Tl MANUAL BLDG PLAN CHECK FEE PARKING IN-LIEU FEES Total Fees: $81,308.00 Building Division Property Owner: STATE STREET COMMONS, LLC 2659 STATE ST, # 100 CARLSBAD, CA 92008-1627 (619) 840-7721 Total Payments To Date: $81,308.00 CoApplicant: C2 BUILDING GROUP 107 S CEDROS AVE, # STE 220 SOLANA BEACH, CA 92075-1994 (858) 232-0213 Balance Due: AMOUNT $628.00 $2,000.00 $78,680.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov Plan Check Est. Value (_ City of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 PC Deposit ________ _ Date --1'\o..,_,,_/.:...,l/,_,i'-9,___ Suite: ___ APN: 2.DJ -IK I -1 'f · 00 JobAddress "2.7i/2-Z7S2 S·hth: Sfn,,,t Tenant Name: Stat, S-h:ec+ lnmrYbN LLG CT/Project#:. _________ Lot#: ___ _ Occupancy: 8 A -2 i ~ Addition/New: _ __,_,....,._.._--\--=-"----New SF and Use, -~J _________ New SF and Use, ____ Deck SF, ~ 200 Patio Cover SF (not including flatwork) D Tenant Improvement: _____ SF, _____ SF, Existing Use ______ Proposed Use _____ _ Existing Use Proposed Use ------ 0 Pool/Spa: _____ SF Additional Gas or Electrical Features? ------------ D Solar: ___ KW, __ Modules, ___ Mounted, Tilt: Yes/ No, RMA: Yes/ No, Panel Upgrade: Yes/ No D Plumbing/Mechanical/Electrical Only: -------------------------- ~ Other: _~I 'l..,..1-03~f6~~--~-~ APPLICANT (PRIMARY) Name: Er re-' Col e:vn,a h Address: 3,;jj He:nr:a" Ave City: ~: ~~o State: Ce-Zip: '1 2 Io'( Phone: (jf_pfJ 71/io-loSl/e Email: _jO>j @, Uc,,ICJ?W.rard,. lg m DESIGN PROFESSIONAL Name: 6 Colen-i,,."' An,hd:c,t- Address: 50/L/ tle.r:m4h Ave. City: S!ln bie~ 0 State: c,,. Zip: q2, ol./ Phone: ( ~ o c) 71/4 -I,, Cl le ------- PROPERTY OWNER Name: J ±t11f:c Stre.< t Co Wl(Y'lon ( Address: Zler:-1 S:h.:ite S'trre t # loo City: Gt;~~~ . State: Co., Zip: c:rzooK Phone: (l.l -7 Z Email: br-e:n@, Ak;141nYes±rru:-nl:c ("C/n CONTRACTOR BUSINESS Name: CZ Rulla&.[ Address: / 0 7 5. (e.,/ r-QJ A;ye. 5 u i 1-f 2 2 () City: Jclo~ ~~~b State: Cd\ Zip: '12o]s Phone: (f -=_L __ -OZ j 3 Email: Jo~h@, CZSD.wrn • I Email: .j t<'j@ 3Lple Wl0""'i'ch ,;.,,m Architect State License: _(_'?~S:~J~(o ...... j ____ _ State License: B/i''1D L/08'{) Bus. License: ~2ol 'f 022/p/., (Sec. 7031.S Business and Professions Code: Any City or County which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's license Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she ls exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 B-2 Ph: 760-602-2719 Fax: 760-602-8558 Page 1 of 2 Email: Building@carlsbadca.gov Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: □ I have and will maintain a certificate of consent to self~insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is Issued. □ Certificate of Exemption: I certify that In the performance of the work for which this permit is issued, l shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful, and shall subject an employer to criminal penalties and clvll fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code, Interest and attorney's fees. CONTRACTOR SIGNATURE: __ 117...,_v-+--~----------i)UAGENT DATE: __.:,./_o,_/_l 11-/.._/ "f.,__ ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: □ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner~builder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's license Law). D I am exempt under Section ________ ,Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D Yes D No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (Include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: □AGENT DATE: _____ _ ---------------------- CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civll Code). lender's Name: ______________________ lender's Address: _____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25S33 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D Yes IJl"No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D Yes )t No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes )( No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. t ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST AU LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories In height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 ys (Section '741 Uniform Building Code). APPLICANT SIGNATURE: --'---'--::+-~-------------DATE: Io/, / 11 1635 Faraday Ave Carlsbad, CA 92008 B-2 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 ( City of Carlsbad SPECIAL INSPECTION AGREEMENT B-45 Development Services REC E f VE' ~uilding Division ... ~ ~ Faraday Avenue JAN 2 I 160-602-2719 2020 www.carlsbadca.gov CITY OF-~ ,. ,, In accordance with Chapter 17 of the California Building Code the following mu,s'sf!Shf-ddrli requires special inspection, structural observation and construction material testing. Project/Permit: _pc Z.O I Cf-DO¼ __ Project Address: 27'-IZ -27<;Z Sfp k Sme ± A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder □. (If you checked as owner-builder you must also complete Section B of this agreement.) Name:(Pleaseprint) 6~ ....... . cf:, )el/h<'lvi Mailing Address: .35:1t.f(Fira4:ern1cu,, Ave. I S~n Pie90 I {,,,,_ crz.i°o'f Email:....~vt' j e..j_(,t>lg'"tl'lll 1-\t,trch ...co~-----Phone: ftos:-7:I.IR..:JR.r....,l/p.,.__ I am: □Property Owner □Property Owner's Agent of Record ~Architect of Record □Engineer of Record State of California Registration Number C 3 s· 7 '1 / Expiration Date: I I 3 I / 2./ I t AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of :::~:~~~~pections teBon th~•:~·~~:~ required by the Cali=~~~~ ~~ldz?c;i• 71J20_ B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder / owner-builder. Contractor's Company Name: __ c.c__z._~&J~-' -"-~---l,.j_'_~,___y,___f2-f>_J~P _____ Please check If you are Owner-Builder □ Name: (Pleaseprint) ___ _,.p:f ____ ~--------~-------~S=[~M~A.~~~----- (Flrst) (M.I.) (Last) Mailing Address: 107 s. CE-Df'.-V'.)_M~c-~_2_7-0 / Si,•LA:rJ,I\ &~~~ Cl\ °l2V7S, Email: PT(? C.:Z....6D vtM.. Phone:._'?._s_· _3_._2,_S_S_-~/_5_~_5 __ State of California Contractor's License Number:__,f,.,.__-_<J ....... 9wk<-L...,/'-'SLb,.,· ___ Expiration Date: (,ff /3a / 2D z.o I • I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have in-place procedures for exercising control within our (the contractor"s) organization, for the method and frequency of reporting and the distribution of the reports; and • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. • I will provide a final report/ letter In compliance with CBC Section 1704.1.2 prior to requesting final inspection. Signature_· __ ?C"-·,-.,_. ~. 1--· _· ~---...,-,.___-__ · ___________ Date: ~ ......---· 0 t / t 7 / 7,:-0z._O • I-~~---- B-45 Page 1 of 1 Rev. 08/11 DATE: JAN.28,2020 JURISDICTION: CARLSBAD PLAN CHECK#.: PC2019-0066 ✓• EsG1I A S.A.FEbwlt Cornpc111y SET: III PROJECT ADDRESS: 2742 · 2752 STATE STREET PROJECT NAME: STATE STREET COMMONS* □/4PUCANT I JURIS. l2sJ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: l2sJ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Greg Coleman, AIA Telephone#: 805-746-6516 Date contacted: t/gofU:i,by~ Email: greg@gcolemanarch.com Mail Telephone Fax In Person 0 REMARKS: By: ALI SADRE, S.E. Enclosures: EsGil 1/21 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: DEC. 10, 2019 JURISDICTION: CARLSBAD PLAN CHECK#.: PC2019-0066 ✓• EsG1I A SAFEbui!fCompany SET: II PROJECT ADDRESS: 2742 -2752 STATE STREET PROJECT NAME: STATE STREET COMMONS* □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. PLEASE SEE BELOW D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Greg Coleman, AIA Telephone#: 805-746-6516 ~ ate conta : 12.-!H'\ (by1c'-) Email: greg@gcolemanarch.com ~Mail Fax In Person ~ REMARKS: Pie e see attached for remining items from previous list. By: ALI SADRE, S.E. Enclosures: EsGil 11/27 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 • . d"ARLSBAD PC2019-0066 DEC. 10, 2019 GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring J:oll/SJ. corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. PLANS 3. Please specify the total floor area of the 1st level= 16,683, on Sheet G1 .3. 4. Please indicate the actual versus allowable area, per floor, i.e.: [B Actual/ B Allowable) + [A Actual/ A Allowable) S1 .0. Repeat this for the entire building as well. What is presented, on Sheet G1 .3, is incorrect. It does not include covered outdoor areas. Also, the values used are not consistent. 5. Revise the stairs by gridline #12, to show 44" min. clear width, serving an occupant load (OL) of 82, which is over 50. What is shown on the floor plans and Sht. A6.1 is incorrect. The total OL shall be used to determine the required width of the stairs, in case one stair is blocked due to fire. See the IBC illustrated handbook. Sec. 1011.2. 6. Please call out the glazing on Sht. A2.0, near grid points D-3, C-6, etc. 7. On Sheet A2.0, label the doors to the restroom and to the storage room. 8. Please fill in the blank wall designations on Sheet A2.0, near grid point D-11. Similarly, on Sht. A2.2, near grid point D-11 (3-locaitons) for walls & glazing. FIRE BARRIERS 9. Structural members supporting a horizontal fire barrier must have the same fire-rating as the separation. Section 707.5.1. This means all the beams. columns and walls supporting the floor above shall be one hour rated between BIA2. Revise the designations on Sheet G 1.4 for rated walls. floors & rated elements. 10. Provide details on plans for the fire-rated construction. Include floor/ceiling assemblies, column and beam assemblies, etc. Be sure to list with each detail the basis of approval (U.L. listing #, ICC research report, etc.). Please cross reference the rated assemblies on floor plans, section plans, etc. STRUCTURAL ······--··-···--- - <!KRLSBAD PC2019-0066 pEC. 10, 2019 11. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: a) The building pad was prepared in accordance with the soils report, b) The utility trenches have been properly backfilled and compacted, and c) The foundation excavations comply with the intent of the soils report." 12. City Policy requires that their Special Inspection Agreement Form be completed, signed and returned for this project. This Form is available at the building department. MISCELLANEOUS 13. Please see attached for any remaining P/M/E items. 14. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact ALI SADRE, S.E. at EsGil. Thank you. PLUMBING AND MECHANICAL COMMENTS PLAN REVIEWER: Connor Reuss SET: II PLUMBING (2016 CALIFORNIA PLUMBING CODE) 15. To ensure the grease interceptors will be sized properly, please provided estimated DFU for each. Note: Approval by Authority Having Jurisdiction is required if grease interceptors are to be shared by different business establishments. CPC 1014.3.4.21 Regarding the middle building and barrel roofed building, provide documentation from the Building Official allowing the x2 establishments to share a common grease interceptor. CPC 1014.3.4.2 16. On sheet P2.3, specify why portions of the roofs is not equipped with primary and overflow storm drains. I Please address the following: a) Architectural plans do not show the gutters or leaders for the bridge and right-hand building (on sheet A2.4). b) Mechanical equipment typical sit flat per manufacture's specification yet sheet A2.4 shows the right-hand building sloped. Please address. c) The mechanical well screen on the right-hand building is enclosed. It appears storm water will be trapped. Please address. d) Please see mechanical comment below regarding the roof hatch/guard rail. . ;.!iRLSBAD PC2019-0066 DEC. 10, 2019 . MECHANICAL (2016 CALIFORNIA MECHANICAL CODE) 17. Buildings of more than 15' in height shall have an inside means of access that meets the design requirements of CMC 304.3.1.1. Please provide City approval for use of an outside ladder is required. I Please address the following: a) The roof hatch shown on sheet A2.4 required a 42" guard rail since it is within 10' of the roof edge. Note: Due to the current storm water design (i.e. since the roof is shown to drain toward this side of the roof), a parapet cannot be used (i.e. it will trap of the water on the roof). Please address. b) Please specify how the barrel roof mechanical units will be able to be accessed. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Connor Reuss at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. DATE: OCT. 14,2019 JURISDICTION: CARLSBAD PLAN CHECK#.: PC2019-0066 ✓• EsG1I A SAFEbuilfCompany SET: I PROJECT ADDRESS: 2742 -2752 STATE STREET PROJECT NAME: STATE STREET COMMONS* □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Greg Coleman, AIA Telephone#: 805-746-6516 iS.Date--con · ~ -(L.1 ~1(by:'.fb ) Email: greg@gcolemanarch.com Mail Telephone ax In Person REMARKS: *Due to th very extensive renovations of these three existing buildings, affecting their roof framing, floo · , a 10n and their lateral force resisting systems, they are considered as new for the purpose of plan review. [This is a w_c1rm shell, the T.I. work will be under a separate permit]. By: ALI SADRE, S.E. Enclosures: EsGil 10/03 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 ·--->'·----.. -· CARLSBAD PC2019-0066 OCT. 14, 2019 GENERAL PLAN CORRECTION LIST JURISDICTION: CARLSBAD PLAN CHECK#.: PC2019-0066 PROJECT ADDRESS: 2742 -2752 STATE STREET CONSTRUCTION = V-B; STORIES = V-B; SPRINKLERS = YES; OCCUPANCY = B/A2 AREAS: 1sT FLOOR= 11,092; 2ND = 7,946; PATIOS= 5,200-S.F.; DATE PLAN RECEIVED BY ESGIL: 10/03 REVIEWED BY: ALI SADRE, S.E. FOREWOR (PLEASE READ): DATE REVIEW COMPLETED: OCT. 14,2019 This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring Tif'1!J. corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. 3. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? D Yes D No PLANS ·---·-.. ·--~,,-·-·· CARLSBAD PC2019-0066 OCT. 14,2019 4. Please specify the total floor area of the 1st floor= ... ; 2nd floor= ... on the plans. 5. Please note the total floor area of the covered patios including that under the 2nd floor between buildings B & C. on plans. Also, add this to the total building areas on the cover sheet of the plans. See Sec. 202 for the definition of floor areas. 6. Please indicate the floor areas for the future B occupancies as well as A2 occupancies on the cover sheet of the plans (including covered patios, i.e., for A2). 7. Please show that the total actual areas do not exceed the total allowable floor areas, per floor and in total (for both levels), including the covered patios. This should be presented as the sum of the ratios of each occupancy: B (actual area)/ (allowed area) + A2 (actual area)/ (allowed area) s 1.0. TBL 506.2. 8. Guards (Section 1015): a) Shall be detailed showing adequacy of connections to resist the horizontal force prescribed in Section 1607.8.1. Please show structural connection details for the guardrails on plans with supporting calculations. 9. Please provide notes on the plans to show the suspended ceilings in Seismic Design Categories D, E & F comply with ASCE 7-10 Sec. 13.5.6.2.2 as follows: a) All ceilings shall use a Heavy Duty T-bar grid system. b) The width of the perimeter supporting closure angle shall be not less than 2 inches. c) In each orthogonal horizontal direction, one end of the ceiling grid shall be attached to the closure angle. d) The other end in each horizontal direction shall have a¾" clearance from the wall and shall rest upon and be free to slide on a closure angle or a listed assembly. e) Ceiling areas over 1,000 ft.2 must have horizontal restraint wires (typically restraint would consist of four 12 gauge wires splayed 90° to each other and sloped 45° to the horizontal, spaced 12" o.c.). f) Ceiling areas over 2500 ft.2 must have seismic separation joints or full height partitions. g) Ceilings without rigid bracing must have 2" oversize trim rings for sprinklers and other ceiling penetrations. 10. Show, or note, that an additional sign shall also be posted in a conspicuous place at each entrance to off street parking facilities, or immediately adjacent to and visible from each stall or space. Section 11 B-502.8.2. The sign shall be ~17" x 22" with lettering not S1" in height. The required wording is as follows. "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or SPECIAL license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ______ or by telephoning ______ " The word Special is left out of the sign verbiage. See detail 11/G1.3. 11. Specify on the plans that portable fire extinguishers will be installed in the building in accordance with Section 906. CARLSBAD PC2019-0066 OCT. 14, 2019 12. Note on plans: "All egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort." Section 1010.1.9. In lieu of the above, in a Group B occupancy (or Group A occupancies having an occupant load of 300 or less), you may note on the plans "Provide a sign on or near the exit door, reading THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED." This signage is only allowed at the main exit. Section 1010.1.9.3. 13. Each door in a means of egress from an occupancy of Group A having an occupant load of 50 or more shall not be provided with a latch or lock unless it is panic hardware. Section 1010.1.10. 14. All doors within the exit path to a public way from an occupancy of Group A having an occupant load of 50 or more shall not be provided with latches or locks unless they are equipped with panic hardware. Sections 1010.1.10 and 1010.2. 15. When additional doors are provided for egress purposes, they also shall conform to the requirements of Section 1010 (width, swing, hardware, etc.). Section 1010.1. 16. Where is door D19 called out on the plans, as per Sheet A5.0, door schedule. Also, complete the door info. on door schedule. 17. Please identify all tempered glazing on Sheet A5.3 for windows within 24" of doors and within 18" of floors. Sec. 2406.4. 18. Please note where window W15, as per schedule, on Sht. A5.3, is referenced on plans. 19. Please cross reference all the interior partitions to the details on the plans. Include stud size and spacing, gage, span, shot pins diameter, spacing at ends and corners, embedment, penetrations, ICC approval#, etc., on the plans. 20. Revise the stair width to show 44" min. clear width for each stair serving an occupant load of 79 people, which is over 50. See the IBC illustrative guide. Sec. 1011.2. 21. Specify the roof slope for all areas & note class A roofing materials on Sht. A2.4. City Policy. FIRE BARRIERS 22. A one-hour fire barrier separation is required between A & B occupancies. Table 508.4. 23. Doors and fire shutters in fire barriers shall comply with Table 716.5: FIRE BARRIER RATING hours MINIMUM OPENING PROTECTION ASSEMBLY hours 1 ¾ 24. Structural members supporting a horizontal fire barrier must have the same fire-resistive rating as the separation. Section 707.5.1. 25. Steel electrical outlet boxes at fire barrier walls shall not exceed sixteen square inches, shall not exceed 100 sq in per 100 sq ft of wall, and shall be separated by a horizontal distance of twenty-four inches when on opposite sides of a wall. Section 714.3.2. CARLSBAD PC2019-0066 OCT. 14, 2019 26. Ducts penetrating fire barriers at occupancy separations must have fire dampers. Section 717.5.2. On a key plan show the location of A & B occupancies with details & references for the rated construction on plans. 27. 28. 29. 30. 31. 32. 33. a) In CA, Section 717.5.2 was modified for Group A occupancies, to require smoke dampers in addition to fire dampers. Provide details on the plans for the fire-resistive construction. Include floor/ceiling assemblies, wall assemblies, column and beam assemblies, etc. Be sure to list with each detail the basis of approval (U.L. listing number, ICC research report, etc.). Detail how fire-resistive wall construction will be maintained at built-in wall fixtures and behind mailboxes, fire extinguisher cabinets, electric panels exceeding 16 square inches in area, etc. Section 714.3.2. Detail on the plans how fire-resistive wall and ceiling protection will be maintained at all duct penetrations, such as at fans and vents. Section 717. Fire dampers shall be installed per Section 717.5 at all duct and air transfer openings of: a) Fire barriers. Smoke dampers shall be installed per Sec. 717.5 at all duct and air transfer openings of: a) In California, Section 717.5.2 was modified for Group A occupancies, to state that duct openings in fire barriers shall also be provided with smoke dampers. If smoke dampers are required, the plans shall show the locations of the smoke detectors listed in the options of Section 717.3.3.2 of the CBC. Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor-ceilings and roof-ceilings shall be protected as required in CBC Section 714." CITY POLICY 34. For plans submitted to the City on or after 4/12/19, the following Electric Vehicle requirements apply, per Carlsbad ordinance: Non-residential: Carlsbad amended the California Green Code, as follows. The California Green Code provisions apply to new buildings and to alterations (if the alteration shows parking spaces being added). Please show step- by-step how the project complies with the following City Policy: • "EVSE capable": 1" raceway terminating into an adequately sized (amperes) panel and an enclosure (parking end) the location identified on the building plans. If common use parking is available at least one capable space is required. • "EVSE ready": Panel capability, 40A 2 pole breaker, 1" raceway, No. 8 conductors installed to the anticipated charger location. • "EVSE installed": Panel capability, 40A 2 pole breaker (per space), 1" raceway (per space), electrical vehicle charging equipment and No. 8 conductors installed to the charger location. TABLE 5 106 5 3 3 ... TOTAL NUMBER OF NUMBER OF REQUIRED EV NUMBER OF REQUIRED ACTUAL PARKING SPACES EVSE INSTALLED SPACES SPACES 0-9 1 1 10-25 2 1 26-50 4 2 -----------· -··--···. . .... ·--..... . CARLSBAD PC2019-0066 OCT. 14, 2019 51-75 76-100 101-150 151-200 6 3 9 5 12 6 17 9 201 and over 10 percent of total1 50 percent of required EVSE Installed spaces' 1. Calculation for EV spaces and EVSE Installed spaces shall be rounded up to the nearest whole number. The "Number of Required EVSE Installed Spaces" column in the table will require a completed EV charging station design. The "Number of Required EV Spaces" column in the table may be "capable", "ready", or "installed." (See definitions). Accessibility to comply with CBC Table 11B-228.3.2.1 and space design of 11 B-812.6 is required. STRUCTURAL 35. The City Policy requires a soils report for this project. Please reflect the report information on Sheet S1 .0. Section 1803.5.11. 36. Specify on the foundation plan or structural specifications sheet the soil classification, the soils expansion index and the design bearing capacity of the foundation. Sections 107.2 and 1603.1.6. 37. Note on plans that surface water will drain away from building. The grade shall fall a minimum of 5% within the first 10 feet (2% for impervious surfaces). Section 1804.4. 38. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing th at: a) The building pad was prepared in accordance with the soils report, b) The utility trenches have been properly backfilled and compacted, and c) The foundation excavations comply with the intent of the soils report." 39. Provide a letter from the soils engineer confirming that the foundation/ grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soil report are properly incorporated into the plans. This only applies to the expanded foot print of the building. 40. Please complete the blank bubble on detail 2/SD1. 41. City Policy requires that their Special Inspection Agreement Form be completed, signed and returned for this project. This Form is available at the building department. 42. Please provide a legend on Sheet S4.0 for the cross hatched area, by stairs. 43. All the details, as referenced on 14, 15 & 16/SD4 are incorrect. 44. Please specify where detail 1 0/SD4 is called out on the plans. 45. Please note where details 1 & 12/SD5 are referenced on plans. 46. Please indicate where details 8 & 9/SD6 are cross referenced on plans. CARLSBAD PC2019-0066 OCT. 14,2019 47. Please note where details 4 & 16/SD7 are called out on the plans. 48. On detail 6/SD3, please specify the diameter of the shot pins into the wall. Also, add them to the list of items requiring Special Inspection on Sheet S1 .1. 49. Please add the design live loads for the stairs on Sheet S1 .0. 50. Please show drag ties to the SMF on gridline "B''. I.e., add ref. to Sheet S4.0, of elevation 1/SD2. 51. Please show the interaction between the CMU wall and the new Frame Column near grid point A-13, on Sheet S4.0. 52. Please specify the R, 0, p & Cd factors for the SMF's on Sheet S1 .0. Similarly, for the cantilevered column elements, at patio cover supports. 53. The connection of the Steel Frame to the Column Base shall be designed to transmit forces to the foundation per CBC. Column base elements include anchor bolts, base plate welds, and any elements that transfer shear, moment, or tension to the foundation: AISC 341-D1-4a(2). a. The seismic loads to be transferred to the foundation interface shall be based upon the seismic load combinations of ASCE 7-10, Section 12.4.3.2. b. Design of concrete elements at the Column Base, including anchor rod embedment and reinforcement steel, shall be in accordance with CBC, Chapter 19. c. Grade beams shall be provided with ductile detailing per ACI 318, Sections 18. 7 & 18.13. 54. Seismic Load Effect i,iiii■I■ b) Seismic load effect, E. The seismic load effect, E, should be computed in accordance with the following equation set forth in ASCE7-10, Section 12.4.2: E =pQE + 0.2SosD c) Maximum seismic load effect, Em. The maximum seismic load effect, Em, should be computed in accordance with the following equation set forth in ASCE7-10, Section 12.4.3 to be used in the special seismic load combinations of Section 12.4.3.2 Em = OoOE + 0 .2SosO MISCELLANEOUS 55. Please remove the "NOT FOR CONSTRUCTION" stamp on the plans. 56. Please see attached for P/M/E items. 57. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact ALI SADRE, S.E. at EsGil. Thank you. CARLSBAD PC2019-0066 OCT. 14,2019 PLUMBING AND MECHANICAL COMMENTS PLAN REVIEWER: Connor Reuss SET: I ARCHITECTURAL P&M ITEMS 1. The licensed designer must provide a signature to the plumbing and mechanical plans before the plans can be approved. 2. The statement, "Not for Construction," must be removed from the plans before the plans can be approved. PLUMBING (2016 CALIFORNIA PLUMBING CODE) 3. For the water system, to ensure that the 2" water line that serves all x2 buildings is properly sized, please provide estimated WSFU for each building. 4. Please show the required 2% slope of the underground vents. 5. To ensure the grease interceptors will be sized properly, please provided estimated DFU for each. Note: Approval by Authority Having Jurisdiction is required if grease interceptors are to be shared by different business establishments. CPC 1014.3.4.2 6. Overflow roof drains shall terminate in an area where they will be readily visible and will not cause damage to the building. If the roof drain terminates through a wall, the overflow drain shall terminate 12" minimum above the roof drain. It appears on sheet P2.1 they are both terminating at 12" AFF. Policy 84-35. Note: Specify why the primary storm drain system is not connected to the public storm water system. 7. On sheet P2.3, specify why portions of the roofs is not equipped with primary and overflow storm drains. MECHANICAL (2016 CALIFORNIA MECHANICAL CODE) 8. On sheet M2.3, it appears PHP-1 & PHP-2 are on the portion of the building where the 2nd floor patio that has no roof to place the units on. Please review with the architect. 9. Buildings of more than 15' in height shall have an inside means of access that meets the design requirements of CMC 304.3.1.1. Please provide City approval for use of an outside ladder is required. 10. Per City of Carlsbad, roof mounted equipment must be screened, and roof penetrations should be minimized. City Policy 80-6. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Connor Reuss at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. CARLSBAD PC2019-0066 OCT. 14, 2019 ELECTRICAL and ENERGY COMMENTS PLAN REVIEWER: Scott Humphrey ARCHITECTURAL PME ITEMS 11. The licensed designer must sign the approved set of the plans. 12. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. 13. Please remove the statement "Not for Construction." ELECTRICAL (2016 CALIFORNIA ELECTRICAL CODE) 14. Provide a single line diagram for the new service. Include the following information: • For fault current mitigation, describe the electrical distribution equipment design as "engineered", "fully rated" or "series rated". Include the AIC specification rating of overcurrent devices throughout the system. 15. Sheet E4.1 -House PNL, the feeder to this PNL is undersized. ENERGY (2016 CALIFORNIA BUILDING ENERGY STANDARDS) 16. Energy is approved. Note: If you have any questions regarding this Electrical, Plumbing, Mechanical, and Energy plan review list please contact Scott Humphrey at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. CARLSBAD PC2019-0066 OCT. 14, 2019 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PREPARED BY: ALI SADRE, S.E. PLAN CHECK#.: PC2019-0066 DATE: OCT. 14, 2019 BUILDING ADDRESS: 2742 -2752 STATE STREET BUILDING OCCUPANCY: B/ A2; V-B/SPR. BUILDING AREA Valuation Reg. PORTION ( Sq. Ft.) Multiplier Mod. blda. areas 19038 104.78 patios 5200 15.41 Air Conditioning 19038 6.47 Fire Sprinklers 24238 4.01 TOTAL VALUE Jurisdiction Code cb By Ordinance 1997 UBC Boildi ng Permit Fee h,.;,I I 1997 UBC Plan Check Fee VALUE Type of Review: P" Complete Review r Structural Only r Repetitive Fee ,. m Repeats ,, r Other r Hourly EsGil Fee -----1]Hr. @ • Comments: ($) 1,994,802 80,132 123,176 97,194 2,295,304 $3,973.16) Sheet 1 of 1 • State Street Remodel ~ A 27 42 State Street , ,, Carlsbad, CA, 92008 o> 0/;-.J-OC'.I' 0~1 0, 0 ()> V_A Structural Calculations -19141 '<) ;<s < d '-'A :q,,Q 0-1,?, ~ V <)/t--c <'~ '(s> o>--1. ~b,z, :o Qualls Engineering Structural Engineering Services > t--0 Greg Coleman Phone: 805-746-6516 [Y 1( ... ·'.I q -frv\l ,lri, 1 ··'VO(_. · 1 , l/t/,(J(/_; ' Qualls Engineering Structural Engineering Services GOVERNING CODE: CONCRETE: REINFORCING STEEL: STRUCTURAL STEEL: MASONRY: SAWN LUMBER: ENGINEERED WOOD Project: State Street Engineer: _C_G _________ _ DESIGN BASIS 2016 CBC f, = 3,000 psi (MINIMUl>l) ASThl ,-\615, F, = 60 ks1 ,-\SThL-\992, F, = 50 ksi ("\V" SK-\PES ONLY) Sheet 1/37 Job#: 19141 Date: 9 /27 /19 ,\SThl ,\36, F, = 36 ksi (STRUCTURAL PL-\TES, ,-\NGLES, CHANNELS) ,-\STM A500, GR C, F, = 50 ksi (STRUCTUIL-\L HSS TUBES) f m = 2,000 psi (MINfolU~l) D< JUGL-\S FIR L-\RCI I, ALL< JW,\BLE STRESS DESIGN PER 2016 CBC BOISE C-\SC-\DE OR EQUI\'.-\LENT BC! WOOD "I' JOISTS -ICC-ESR 1336 PROJECT SCOPE Project consists of a proposed approximately 3,300 square foot quonset remodel, and a 21,000 square foot two-story mixed-use remodel, located at 2742 State Street, Carlsbad, CA 92008. The proposed structures are primarily constructed utilizing metal stud construction with a metal joist framed roof, wood framed floor, and typical slab on grade with turned down footings. There has not been a soils report provided for this project. Therefore, the foundation design will be based on minimum soils values per 2016 CBC chapter 18. ' \ Qualls Engineering Structural Engineering Services Design Loads: Pitched Roof: Dead Load ( DL ) Roofing 1 /2" Plywood Truss Framing Insulation 1 /2" Gyp. Bd. Mech./Elec. J\lisc. DLI = Live Load ( LL ) Project: Engineer: 5.0 psf 1.8 psf -1-.0 psf 0.5 psf 2.2 psf 0.5 psf 1.0 psf 15.0 psf State Street Floor: Dead Load ( DL) Flooring 2" Gypcrete 3/4" Plywood Framing Insulation 5/8" Gyp. Bd. Mech./Elec. Misc. DLI = Sheet: 2 Job#: 19141 Date: 1.0 psf 18.0 psf '.U psf 2.0 psf 0.5 psf 3.0 psf 1.5 psf 1.7 psf 30.0 psf LL I = ____ __,_ 20.0 psf (Reducible) Live Load ( LL ) Walls: I DL +LL = Stud Walls Exterior \Valls Interior \Valls Allowable Soils Bearing Pressure: 35.0 psf Deck: 15.0 psf "'.U psf LL I = 65.0 psf IDL +LI .= 95.0 psf Dead Load ( DL) Dex-O-Tex 2.5 psf 3/4" Plywood 2.3 psf Framing 2.9 psf Stucco 10.0 psf Misc. 2.3 psf DLI = 20.0 psf ASBP =1,500 psf @ 12 inches below lowest adjacent finished grade. Seismic: Site Class: D Ss = 1.1 56 s, = (l.-1--1-3 Occupancy Category II Fa = 1.037 Fv = 1.558 Response Importance i\.fod. Factor Factor, I R 1.00 6.5 Wind Load: (ASD) Basic Wind Speed: Exposure: Importance Factor J\f\VFRS 110 mph C 1.00 P = (0.6) Lambda x K.,, x I x P,311 P = 13.7 psf Components & Cladding p = (0.6) Lambda X K /.l X I X pnct30 P = 2 1.1 psf Lambda = K" = P,30= s~,s = 1.199 s·"' = o.690 Redundancy Factor, rho l.3 1.29 1.0 17.7 27.2 Cs S0s/(R/l) ( LR.r-D ) 0.160 Cs Sos= 0.799 S0 1 = 0.460 Sos/(R./I) (.\SD ) 0.114 ' \ Qualls Engineering Sheet: 3 ----- Structural Engineering Services Project: State Street Job#: 19141 Engineer: --'C=--=G=-------------Date: Lateral A nalysis (Main Building) Level Component Weight (psf) Main Roof 15 Partitions 5 Roof Ext Stud Wall 15 8" CI\-IU Wall 84 G lazing 10 Main J•loor 30 Partitions 10 2nd Floor Canoov 15 Ext Stutl Wall 15 8" CMU Wall 84 G lazinl.!: 10 C, (ASD) W (lbs) V (lbs) 0.114 1,003,431 114,391 Level W, (kips) h, (ft) Roof 384.7 25 2nd Floor 618.8 13.5 ,·. c, X 0.02 25 0.75 Ps 13.7 North-South Level Height (ft) Diaphragm Depth (ft) Roof Peak 25 - Roof 25 I 109 2nd Floor 13.5 162 ~: Direction Governing Load North-South Seismic I 7.7 psf liast-Wcst Seismic I 7.7 psf Tributary Area (ftl Tributary Tributary Weight Length (ft) Height (ft) (lbs) 12,646 189,690 12,646 63,230 384 11.5 66,240 139 16.0 186,816 91 11.5 10,465 8,845 265 350 8,845 88,450 1,097 16,455 214 13.5 43 335 151 13.5 171,234 140 13.5 18,900 "· W,h/ (k-ft) W.h: V. (lbs) I:(W,h/) 9,617 0.54 6 1,218 8,353 0.46 53,173 17,970 k 0.22 1.0 Wind Check V. (psf) - 0.7 I.I 1.8 IWeight (lbs) 384,681 618,750 1,003,431 Area (ftl 12,646 18,787 ,·. Level Roof Peak Roof 2nd Floor v. (psf) 4.8 2.8 7.7 3.6 (w/o CMU) 2.0 (w/o CMU) East-West Height (ft) Diaphragm V. (psf) Depth (ft) 25 -- 25 I 95 0.8 13.5 141 1.2 ,·. 2.0 \ Qualls Engineering Sheet: 4 ---- Structural Engineering Services Project: State Street Job#: 19141 Engineer: ....::C:....:G=---------Date: Lateral Distribution (Main Building) N -S Roof / Diaphragm load (psf) '? ~ Diaphragm load (plf) 3.6 98 Grid Area CMU Load Lenath A 971 24 5,905 40 B 1,061 0 3,852 14.5 E 6,238 58 28,337 58.25 H 313 0 1,136 6.75 L1 2,216 0 8,045 22.5 L2 1,845 34 10,025 15.75 N -S Floor 2.0 120 Grid Area CMU Load Load Above A 0 16.5 1,975 5,905 B 1,097 0 2,185 3,852 0 .6 245 22.5 3,181 0 E 3,167 29.5 9,839 28,337 H 4,158 35 12,472 1,136 L1 646 0 1,287 8,045 L2 590 11.5 2,552 10,025 E -W Roof 3.6 98 Grid Area CMU Load Lenath 5-6.2 3,153 0 11,446 61 .8 9 3,869 0 14,044 28.75 10 3,260 0 11 ,833 25.3 13 2,375 116 20,008 116 E -W Floor 2 0 120 Grid Area CMU Load Load Above 5 1,940 0 3,865 11,446 9 3,867 0 7,703 14,044 10 2,485 0 4,950 11 ,833 13 1,655 116 17,182 20,008 olf 148 266 486 168 358 637 Lenath 40 14.5 29.3 81 25.5 3 2- Moment Frame Moment Frame olf 197 416 109 471 534 3,111 6,288 Moment Frame Moment Frame Moment Frame Moment Frame ~#of co lumns and lbs/ col where applicable olf 185 488 469 172 CMU Wall Lenath plf 42 365 46.5 468 58.8 286 116 321 CMU Wall \ Qualls Engineering Sheet: 5 ----- Structural Engineering Services Project: State Street Job #: 19141 Engineer: _C::;.G..::.... _________ _ Date: Lateral Analysis (Quonset) Tributary Area (ft1 Level Component Weight (psi) Tributary Tributary Weight IWeight Length (ft) Height (ft) (lbs) (lbs) Mech'! Platform 30 l,(X)4 30 120 Ouonsct Roof 5 2 311 11 555 Roof Canony 15 1,340 20 100 78,M,3 Ext Stud Wall 15 83 14.5 18 053 Glazinl! 10 91 17.3 15,724 C, (ASD) W (lbs) V (lbs) V (psi) 0.114 78,663 8,968 1.9 Wind Check Ps 13.7 North-South East-West Level Height (ft) Diaphragm v. (psi) Depth {ft) Level Height (ft) Diaphragm v. (psi) Depth (ft) Roof Peak 22.ll -Roof Peak 17.3 - Roof 22.ll 41 3.7 Roof 17.3 80 1.5 "· 3.7 ,·. 1.5 Direction Governing Load North-South Wind I 3.7 osf East-West Seismic r 1.9 osf Qualls Engineering Structural Engineering Services Project: State Street Engineer: -"C'-"G'----------- Lateral Distribution (Quonset) N-S Roof 37 Grid Area Load LenQth nlf A 464 1,705 3 568 lbs/col D 1,830 6,726 11 611 F.6 1,868 6,866 12 572 J 502 1,845 25.25 73 E-W Roof 1 9 Grid Area Load Lenath olf 1 2,998 5,775 16.5 350 4 1,658 3,193 19.25 166 Sheet: _6~-- Job #: 19141 Date: Qualls Engineering Structural Engineering Services Lateral Analysis N -S Roof -::i 2 '/. 0 '" -::i 2 '/; "'1-('J Project: State Street Engineer: ....:C::...G=----------- -"' ><~ 'ti M N r------......!"~·+--_::__:__11··-·-· ~·-··-· c-i ~ :... t t t t /. "-i--, :e C)=g_ "' Jj -~ =oe-~c~ ;; p ~ ~ -.r~ cc ~ '/4 :.0 ~ '£ "'° .r, /; -::, ::::. ..,: If") ....: ...--: ...::, ~~~ 00~ 0 f: 00 .._, ff"\ .~-('J '" Sheet: 7 ~--- Job #: 19141 Date: Qualls Engineering Structural Engineering Services Lateral Analysis N -S 2nd Floor <'I -,. t ] Jj ~ -"' t :r oc + --:: /. t; :2 r,. -✓• ho 7. £ C"'! ..... = Project: State Street Engineer: _C_G~-------- .,. ·r. ~ ._, .,_ ~ r-e') "' oc "' + I ., . . ,. ~ ._, Sheet: _8=------ J ob#: 19141 Date: Qualls Engineering Structural Engineering Services Lateral Analysis E -W Roof ~-t' StuJ 80' Stud Sheet: _9 ___ _ Project: State Street Engineer: _;C::....G=---------- Job #: 19141 Date: 50' SruJ X 5 968 sf 16' SruJ 16' Stud 33' StuJ J .. , -W' Stud -..• L..::._ T·-· ~- 1 • .• - 116'C\IL' ~~-,======~~~E!±~~ "'- 33' Glass 11,446 lbs (.\SD) 185 plf 60' Stud 14,044 lbs ( \SD) 1,003 plf Ii' Stud ~----~A-c=±=-1'--L 3i' Srud ___ ..,. ""-, 18' Glass ]".. __ L.J... _ _.... __ • 11,833 lbs (.\SD) 469 plf ~0,008 lbs (.\SD) I ,~ plf 40' Class Qualls Engineering Structural Engineering Services Lateral Analysis E-W 2nd Floor -11' (;la,,; Project: State Street Engineer: --'C'-G-'----------- Sheet: -=-1-=-0 __ _ Job#: 19141 Date: 116' C\ll ' 5,-"'5 lb, (.\SI)) 350 pit" 3.193 lb, 3.865 lb, + I 1.-1-1<, lb, 7 .'03 lb,+ I -1,IJ-1-1 lb, -1.950 lb,+ I 1.833 lb, I"' .182 lb,+ 20.008 lb, ( \SD) ( \SI)) 166 pl f 365 pl f ( \SD) (.\SD) ( \SI)) 621 plf 286plf 321 pit Qualls Engineering Structural Engineering Services Project: Sheet: ....;1:;..;;1_,_/ __ Job #: )q / l/ I Engineer: ____..["""b..__ ______ _ Date: Shearwall Design Levd: ......... fvV-£.""-'f ______ _ Direction: N-5 V psf (Unit Shear): ___ psf lw = _____________ ft Grid.line: --=E'----- A, ([rib. Area) = ----------------ft2 F, (Lateral Load) = ________________ lbs Vp1r(Unit Lateral Load) = '-f~t plf H:W Adjustment (Yp1,x h/2w) = plf Overturning Force _ OK by inspection Lw = _;d_ ft Uplift = __ lf.....,?6'-1_1--'-S.,_)-_,'-"'6-'---'(1-'--) 1_1 ...:;,5.,_)!=S1J.._J _-_'1,.,_. -"-g"'-g __ lbs -r Grid.line: --'-'-H __ _ lw = _____________ ft A, ([rib. Area) = ________________ ft2 F, (Lateral Load) = ________________ lbs V p1r(Unit Lateral Load) = /~~ plf H:W Adjusonem (Yp1r x h/2w) = plf Overturning Force _ O K by inspection L.. = _o__ ft Uplift = _/. ...... 1_'_5_)_-= _ _,_l, 1~5~'k _______ lbs (,14•1.-r1) Grid.line: L I ----lw = _____________ ft A, ([rib. Area) = ________________ ft2 F, (Lateral Load) = ________________ lbs Vp1r(Unit Lateral Load) = J S$ plf H:W Adjustment (Yp1rx h/2w) = plf Overturning Force _ OK by inspection L.. = 11 25 ft Uplift= JSJ/ 5) -' / lbs Grid.line: L Z-lw = _____________ ft A, ([rib. Area) = ________________ ft2 F, (Lateral Load) = ________________ lbs Vp1r(Unit Lateral Load)= {,37 plf H:W Adjustment (Yp1rx h/2w) = ____________ plf Overturning Fo rce _ OK by inspection L-. =Di.ft Uplift = () 7(1 5) -. 6(15 ) (7, IS)( I'!~:. t C/C/'f lbs -CZ "l SW Type: ......... ("'-[ __ Vall= 53CJ plf HD Type: ~ Dul/ T.u= 565 lbs SW Type: ~6£~- V,11 = __ 3~S-=-O __ plf HDType: 1-, J:1 T,.11= j,075 ) lbs SW Type: _Y=-l __ V L.~ If all = -~~-L.!.~--p HDType: HDu!.f T,n= ½ ,$65 i SW Type: _3_[ __ V,u = 710 HD Type: H Vr;I/ lbs plf T,11 = q 5JC) lbs I Qualls Engineering Structural Engineering Services Project: S-¾±c $f /afJ~ Sheet: 12 ---- job#: 1qN/ Engineer: _f'_._(7'---------Date: 1/z../(8 Shearwall Design Direction: N-S ..,r,o-fl J ,evel: ----'4?=-'-( __ _ V p,f (Unit Shear): ___ psf lw = _____________ ft Gridline: _'I=--- A, (f rib. Area) = _________________ ft2 F, (Lateral Load) = _________________ lbs Vpt;(Unit Lateral Load)= 7's plf H:W Adjustment (Vp1;x h/2w) = plf Overturning Force L O K by inspection L-. = 2 S ) ft Uplift = _______________ lbs Gridline: F. 6 lw = _____________ fr A, (f rib. Area) = _________________ ft2 F, (Lateral Load) = _________________ lbs Vp1r(Unit Lateral Load) = S77 plf H:W Adjustment (Vp1rx h/2w) = plf Overturning Force _ O K by inspection L-. =_6_ft Uplift = S7Z(3S)-.6(ISpsf,(LY.NjJ.J1-,6(1S)/3[d6Jlbs -z 2 ? = 7 tY-17 lw = _____________ fr Gridline: __..I)-'-, ..... 6 __ A, (frib. Area) = -----------------ft2 F. (Lateral Load) = _________________ lbs Vr1r(Unit Lateral Load)= 1/M plf H:W Adjustment (Vp1rx h/2w) = plf Overturning Force .l..L OK by inspection I.,.. = 2:12.i ft Uplift = _______________ lbs Gridline: __ E __ lw = _____________ ft A, (frib. Area) = -----------------ft2 F, (Lateral Load) = _________________ lbs Vp1r (Unit Lateral Load)= Lf7J plf H:W Adjustment (Vp1rx h/2w) = plf Overturning Force _ O K by inspection L-. = 2.t.7.5 ft Uplift = __ ,._,,/,,'""'3'"""5=$ __________ 1bs SW Type: ~6_£ __ v.u= JS£'.? plf HD Type: ___ _ T.u= _____ lbs SWType: 3E V,11 = 7/0 plf I-ID Type: ... )IJ fl T,11 = lf,53S lbs SW Type: ~6 E~_ V,11= '3.50 plf HD Type: ___ _ T,11= _____ lbs SW Type: ~3,c_;;;_E __ V,11 = 7/{) plf HD T ype: J-/ PU2 T,11 = 4r1JO lbs Qualls Engineering Sttuctural Engineering Services Sheer: 13 Project: .S1q1'= ..5-te.L,-l Job#: 9/11/ Engineer: I Dare: C/ /2 7/IC/ Sh 11 D . 7 rd 'r 1/\:-r earwa es1gn Level: -----4----~-~!.1'.L~--- D irection: N-5 Vp,f (Unit Shear): ___ psf Griclline: _..;..H __ _ lw = _____________ ft A, (frib. Area) = -----------------ft2 F, (Lateral Load) = _________________ lbs SW Type: .-3'"""[ __ Vr1r(Unit Lateral I ,oad) = 534 plf V.u= J/Q plf 11:W Adjustment (Vp1rx h/2w) = plf HD Type: t± PUS Overturning Force _ OK by inspection T,11 = SJ/iS lbs L,.. = _ll_ ft Uplift = 53Y{l3,s)-.6('1f.S)( I )t~:v-.6(1S;(11)(22 lbs 4"' t i: -z. Griclline: -~P~-- --YJ, 7t I,.,= _____________ ft A, (rrib. Area) = _________________ ft2 I\ (Lateral Load) = _________________ lbs SW Type: 3E MIN Vp1r(Unit Lateral Load)= Ii t plf V,u = 710 plf H:W Adjustment (Vp1rx h/2w) = plf I ID Type: P Q(,I l1/ Overrurning Force _ OK by inspection T,11= '1./125 lbs L,. = _I_/ ft Uplift = _,6~(~2 ~, ~)_-~, {~( ..... IS~)(-=--'J ~l -~· 6~(_S=X~z ..... 2,1-=· __ lbs 4"" -;-- Grid.line: ___ _ I,.,= _____________ ft A, (frib. Area) = _________________ ft2 F, (Lateral Load) = _________________ lbs SW Type: Yp1r(Unit Lateral Load)= _______________ plf V.11 = plf H:W Adjustment (Vp1rx h/2w) = ____________ plf HD Type: Overturning Force _ OK by inspection T.11 = lbs L,. = __ ft Uplift = _______________ lbs Grid.line: ___ _ I,.,= _____________ ft A, (frib. Area)= _________________ ft2 F, 0~ateral Load) = _________________ lbs SWT}pe: Vp1r (l.init Lateral Load)= _______________ plf V,11 = plf H:W Adjustment (Vp1rx h/2w) = ____________ plf HD Type: Overturning Force _ OK by inspection T,11 = lbs L,. = __ ft Uplift = _______________ lbs Qualls Engineering Structural E ngineering Services Project: 5-/qie 5~rec,i Sheet _1_4-/~-- Job#: AP/ Date: Engineer: (,,(;, -~-------- Shearwall Design Level: ___.P_..oa""-t......._ ___ _ Direction: [ -V Vp,f (Unit Shear): ___ psf Gridline: 5 ~ ft, L lw = ____________ _ ft A, (f rib. Area) = ft2 F, (Lateral Load) = ________________ _ lbs Vp1t(Unit Lateral Load) = ----~)JS _________ _ plf H:W Adjustment (Vp1rx h /2w) = ___________ _ plf Overturning Force _ OK by inspection Lw = ..i2. ft Uplift= JS(! 5') -J SJ 50 'P 75) C> lbs 2 Gridline: __ I) __ _ lw = ____________ _ ft A, (f rib. Area) = ft2 F, (Lateral Load) = ________________ _ lbs Vp1f(Unit Lateral Load)= _____ ../~'g~,6~--------plf H:W Adjustment (Vp1rx h/2w) = ___________ _ plf Overturning Force _ O K by inspection Lw = ..11_ ft uplift = ~l/8~8~, ~11-s _-~· 6~!~2-X.......,.so~)~( 2==-?>.,..._) __ _ ( <n-rr,, ...,. ,; ) -"i' lbs -.61 5)1 '(:,):: l1S rt Gridline: -~/0~-- t\, (f rib. Area) = -=r: lw = ____________ _ F, (Lateral Load) = ________________ _ Vp1r(Unit Lateral Load)= -------'L/...,_1,(4 ________ _ H:W Adjustment (Vp1rx h/2w) = ___________ _ Overturning Force _ OK by inspection ft ft2 lbs plf plf L.. = lb c; ft uplift = -~"'J.'--4-/_1,_i::_-..:..,• , ..... r ..... 1...,,).,_1_'-'-l --"'!!,_Su.;_:::_l.4=.3::...:S:c..c'f __ lbs r,,,,J,-,r,-,, ) ? ''2., Gridline: ___ _ lw = ____________ _ ft A, (f rib. Area) = ft2 F, (Lateral Load) = ________________ _ lbs V p1r (Unit Lateral Load) = _____ l 7~2 ________ _ plf H:W Adjustment (Vp1rx h/2w) = ___________ _ plf Overturning Force ~OK by inspection k. = _,.,__ ft Uplift= ______________ _ lbs SW Type: 6[ V.u= ]SQ plf HD Type: Nont:._ T.u= /,A() lbs SWType:~~£~- V.n= 5:() plf HD Type: Hf){)l Ta11= ;,.07S I lbs SW Type: '>:. v.u = 5~i1 plf HD Type: '1:),t_1 T.11 = ·1 s~s lbs SW Type: C/IV v.11 = plf HD Type: Ta11= lbs ' Qualls Engineering Structural Engineering Services Project: 5-fof& 51 ru-f Shearwall D esign D irection: L hi Grid.line: ___ _ Engineer: I ,eve!: 7/" fla?r Vp,f (Unit Shear): ___ psf lw = _____________ ft A, (Trib. Area) = _________________ ft2 F, (I ,ateraJ I ,oad) = _________________ lbs Yp1,(Unit Lateral Load)= :zSO plf H:W Adjustment (Vp1,x h/2w) = plf Overturning Force _ O K by inspection L.. =~ft Uplift = ~;0(13,S); '-1,7'25 lbs Gridline: __ L~j __ lw = _____________ ft A, (T'rib. Area) = _________________ fc2 F, (Lateral Load)= _________________ lbs V pl• (Unit Lateral Load) = /J.i plf 1:-1 :\V Adjustment (Vp1rx h/2w) = plf O verturning Force _ OK by inspection L., = J115.. ft Uplift = --'l-"'66"--'(_,_/3,_,_,_,__5),_.::____..'24;7.,,._,-'-'l.fl _______ lbs Grid.line: 5 -=----lw = _____________ fr A, (frib. Arca) = ft2 F, (Lateral Load) = _________________ lbs Yp1r(U nit Lateral Load)= ____ 's.c.u..J..~c; _________ plf H:W Adjustment (Vp1rx h/2w) = plf Overturning Force _ OK by inspection L-,. =~ft Uplift = --"'-'.3-"'6..LS_.__( ....... l"z~S)'------'-'' 6"-'('-'-\5,<.J.)C.,..( 2.=5._.)..._{'1:.;..2.....,_) _::::----'7__,.0"-"')'---_ lbs 'l. Gridline: __ rf __ lw = _____________ ft A, (Irib. Area) = _________________ ft2 F, (] .ateral Load) = _________________ lbs Yp11 (Unit J .ateral Load) = 'f/J plf H:W Adjustment (Vp1rx h/2w) = plf Overturning Force _ OK by inspection L.. =~fr Uplift = l/63(1).7) -.6(1S'Xt3,5Jf~)-3,'iq~ 2. lbs Sheet: 15 ---- Job#: 19/Y/ Date: q /l l /11 SW Type: __,6 ...... £"---- V ,u = 10 plf HD Type: ~ [)t)S T,u= 5,6lfS lbs SW Type: ----'-"-6..1::f __ Y:,u= 350 plf HD Type: tf [)(12.. T.11 = '.J,07$ lbs SW Type: ~£ V.11 = S30 plf HD Type: Naac. T,11 = 6M lbs SW Type: ----J~c.::.f __ V.11 = S30 plf HD Type: HPu ~ T,11 = ll,56$ ' lbs Qualls Engineering Structural Engineering Services Project: 5-fcfft,_ 9f1t:l'f Sheet: 16 ---- Job #: FJ!f.// Engineer: ___._&"'----------Date: Shearwall Design Level: Z '0 f l02t Direction: E. -W V psf (Unit Shear): ____ psf Grid.line: --'-}-"-0 __ _ lw = ______________ ft A, (f rib. Area) = __________________ ft2 F, (Lateral Load) = _________________ lbs Yp1f(Unit Lateral I ,oad) = ZZ6 plf H:W Adjustment CVr1rx h/2w) = plf Overturning Force k = 5~.7S ft Uplift = Grid.line: -~3 __ _ OK by inspection 2gt(1),S) -.6(15)/13.S)l5t.75)-= 2Cf 2. -r lbs lw = ______________ ft A, (frib. Area) = __________________ ft2 F, (Lateral Load) = _________________ lbs Vp1r(Unit Lateral Load) = '~2 I plf H:WAdjustmcnt (Vp1r x h/2w) = _____________ plf Overturning Force _LoK by inspection Lu = M_ ft Uplift = _______________ lbs Gridline: ___ _ lw = ______________ ft A, ([rib. Area) = __________________ fr2 F, (Lateral Load) = _________________ lbs Vr1r(Unit Lateral Load)= _______________ plf H:W Adjustment (Vp1rx h /2w) = _____________ plf Overturning Force _ OK by inspeccion 1--. = __ ft Uplift= ________________ lbs Grid.line: ___ _ lw = ______________ fr A, ([rib. Area)= __________________ ft2 F, (Lateral Load) = _________________ lbs Vp1f(Uni t Lateral Load)= _______________ plf H:W Adjustment (Vp1,x h/2w) = _____________ plf Overturning Force _ O K by inspection L. = __ ft Uplift = _______________ lbs SW Type: .... £....,Ee;___ Ya11= 35(2 plf HD Type: None, T.u = _ __./iM......_ ___ lbs SWTypc: ()AU V.11 = ______ plf HD Type: ___ _ T ,u = ______ lbs SW Type: v.11 = plf HO Type: T.11 = lbs SW Type: V.11= plf HO Type: T.u= lbs Qualls Engineering Structural Engineering Services Column Drifts Frame Condition 8 = VV/(12EI) Allowable drift = 2% Load based on R =6.5 1 Building Grid Load Ckios/con A 3.94 Main B 2.47 L1 3.11 L2 6.29 Quonset A 0.57 R 3 4.5 3 3 2.5 Adj. Load Ckios/col) 8.54 3.57 6.74 13.63 1.48 Sheet: 17 ---- Project: State Street Job #: 19141 Engineer: --=C=--=G=-----------Date: Cantilever Condition V > 8 = VL3/(3EI) Height (ft) I (in4) Type 6a (in) 6 (in) 24.33 1,750 Moment Frame 5.84 0.35 18.33 475 Moment Frame 4.40 0.23 13.67 48 Moment Frame 3.28 1.77 11 .67 48 Moment Frame 2.80 2.22 11 .00 15 Cant Col 2.64 2.55 OK! Qualls Engineering Stmcnual Engineering Services Prn1ec.: ___ i \:9Je. S +_r_<~t~t __ _ Engineer: C Gi ----- Sheer: _1_8~/~-- Joh ti. I 01 ~ I Date: V ertical Design Level. R 'OD r D = \ S j)Sf L,t cc:: ~-0-p~r l.l . = ---psf Member: _R;_\s::;._-_\'-------- ~ I t t " Z..l1 v 1 1 R: -~ ~" 6 lbs RI(--= 30~6 lbs Member: p..-,,..., ":>- ---., I j ' t t -" J :, \I 1 1 R· ~ I c;-9 ~o lbs R R -:; \ S:-9 &u lbs '\1ember: R \~ ~ ,,-----~(')' f ~t " 21. 2;' \' 1 1 R, -\\1.':'.)C> lbs Rk :c. I\ 2.9a lbs Member: ______ _ ·f t }-- R1. = lbs R R:::: lbs \V,= 19 h. r ' s -t-2 o i '?. ~ 1 r l r-: \'\-':= P,= P~= Vm .. = __ 1 _~ 9 ~ lbs J\[mu = ------1:._1 C::, 7 ° ft -lbs I,,~·.i = I O 3 6 in-1 W1= ~9.t;;;'/?,.(ls:-.+?u) -867 ~(F W 2= P1 = P:= V,n., = ______ lbs i\1m.~, = ______ ft-lbs In.,.fu = _______ in-1 W:= ,-.,-g 2 i / 2 ( I ;-4 :> c) -I ''l : 7 P ( J: W:= P,= P1= \',n:,,~ = :\Im.u = l "'i" = \'\'1= \'\':= P,= Pi= \' max = 1\1,,,., = (,..~·" = lbs ft-lbs in-I lbs ft-lbs m4 l'st': ~'/ ~ X l~ _ _y J l.. v ,: = I -s ~ 6 ..r a.,s .\.l,u = -~U__!__k__ ft-lbs I = __ \'2....ClO __ i.11-1 V,::= ______ lbs M,11= ______ ft-lbs I = _______ i.n-1 Use: ,,. / ! y ~ '2-. '2-.S 1 , ., I l?. "" I V.u= lbs M,11= ft-lbs I= 1rr• -'If--l>,1 l I l.. ~ I _,. e Use: V,:i= lhs M.u = ft-lbs != U1'1 Qualls Engineering Strucnual Engineering Services Sheet: 19/ Project: S.\-q l...e 3~d:: Job#: I j 14\ Engineer: CC, D:ite: Vertical Design Level: f I D OY D1.= Member: f J -\ ~ 2. (, r-' \t 1 1 R.L = \ 3 6' {; lbs RR= \ ; (: € lbs Member: D ,T-1 ~ \ ,---- t t ~ 2. 1 \t 1 1 R, = l :s 8'o lbs RR= \ 1 ?o lbs M ember: RS-( ~l.j\ t 1' 1£ 1._ 1 ' L, 1 1 R1. = ~y I lbs RR = s-<; l lbs Member: t t 1£ 1 \t 1 R1.= lbs RR= lbs ] 0 psf Ln = ___ psf LL = _£_t,.._ psf W 1= ! 6 '/1 2. ( 3. 0 + 6 f ) \'<':= -1'2--7fl!=- P1= P:= \Tm.a.., = I '.s 6 6" lbs blm.ix = l s 3 g ft-lbs I,L'i'J = ~6 £-' in' \'(',= 12 /I 2 ( 2. O + I 't) .:>):: \ 2-0 p (_(::: \'(,':= P,= P:= Vm,, = \3fo lbs t--fm,.,, = 79'£~ ft-lbs l rc~'d = lr] in• \'<',= 1 t;,'/, 2 C, r ....1-201 -1,7/'C.(- \'(,':= P1= P2= \' ffi~'( = s-y I lbs l\f,...,. = :?Io g ft-lbs l,c~'d = '2... ~ J? in-' \'(,',= W:= P1= P:= \' ma., = lbs l\lm,. = ft-lbs I,e,fJ = in' Use: t b Is(\ S 0 l~l r lbs V,u= M,11= I 1 0 ro f1-lb~ I = 1'2..lr' in' Use: I 6' l'sC I ~ Cl V,n= I~ 7 r lbs M.u= 11 o ro ft-lbs I = 1i.1r in1 Use: 16 ,. 8(1 90 V,u= ,.~1 r-lbs M,u= , 3 or~ ft-lbs I = l"Llt°" in' L'se: V,11 = lbs M,11= ft-lbs I= in1 Qualls Engineering Structural Engineering Services Sheet: 20; P rojecr: Sb\~ H~ ~d Job#: l ~ly I Eng111ce,·: c~ Date: V crtical Design Level: \: \ 0 0'1 D1 = __ 1...c.O_ psf L:1= ___ psf LL c--_i;_.r--_psf t, I 3. ·; r \t 1 ,.., ,., ~(.) 'l RL = .;, lbs RR= 61 0 lbs Member: r::-~ 2... I r.,I ,--1 lv 1 t, I g, \t 1 'l R: = Lt ~ io lbs RR= 2-753 lbs I,, 23.'2. .{ \t 1 'l R1 = 11:iro lb s RH= 'l 20 r D lbs Member: ,,,,.-------l•)~ t t i, '2.':\,1..r'_J,- 1 1 R, = 2 /7 t D lb s lbs \'m:\,. = (\S-] lbs i\1m." = \ 5 '.s IL, ft-lbs I,c~ .i == 3 >~ in" \Y./ I= g I/ 2 ( ::. (J -+ 6 ( ) =-. ' 4 p l i=- \'(! ,= P1~ f< ( r-~ 1) 1:2 ::-b I s-7 1t P:= VmH = LjS-lO lbs 1'1ma., = 2..~~60 fr-lbs r,~q•J = 80 ~ in 1 V.i1= \O~C!o lbs M,u = ~l'?6i., ft-lbs I = I I g l-i in4 l,se: '1 I / ' 2-1 1 (; I/ 1 L V.11= lo6L.o lbs M,11= .,,-;:6.t., ft-lbs I = 11 I g L, in• Wi= '.{., lf:1,-\-\".),(/z.')(1o.i.6r) : 12..(0 f(F 1&2~ l'lj:- V.,,._ = ______ lbs i\lm,. = ___ _ lrcfJ = ____ _ \Y.h= P1= P2= ft-lbs in' Vma., = _______ lbs l\lm,., = ______ ft-lbs l..,,t'J = ______ in4 Use: 'N I Yl ~g C c. :.. 1-/ ~ V,11 = lbs M,11= ft-lbs I= m• V,11= ____ _ tb s M.n = _____ ft-lbs I ~ ______ m4 ) Qualls Engineering Stmcmral Engineering Services Sheer: 21 ; Pro1cct: __ll(A t (. ,.q rut Job#: 13 1" I Engtnccer: C Dare: V crtlcaJ Design Level: ;::. \ O o V -'-::.....::......:...._ ___ _ 1c D· = ---==-psf L,( = ______ psf LL = 6 t" psf M ember: f 13 -S w l i:" L\:>, I l,,,J, L0 53~;r,; ~ 3g ';' \t 1 1 R· = ~ s-7 10 lbs RH = '$$"710 lbs Member: _,__F_B=-·-6=------ ,,,,-----!,j I -t R1.= ~ S-2 0 lbs Rn ::: 1, C-1 0 lbs Member: F ls · 7 ,. t ~ 1 ~' .r ' 1 R1.= '2.. '7 ·' 5 r-o lbs RH -'2. 3 6 S"O lbs Member: .t ts -8 3 3, .r· t \t 1 \t 1 R1 = 3 ~ b 4 O lbs R~ = __ '1_~ 6 (I!_ lbs \'m.-u. = lbs V,11= _____ lbs tvl.,.., = ft-lbs M,11 = _____ ft-lbs ln:y'u = in• I = ______ m• ,+ /I r [ I' t (, \'\', = 7 ; ?... c 1 o + 6 r) \ , c ~ t r -·, g ~ p L r- ,v2= P1= r~= \1,na, -= :VI,,,..,= l,cy'u = lbs ft-lbs in~ V,11= lbs M,n = ft-lbs I = m• w,= ,...1' 2.+-7/2 )(?.o +-6r\ -1z10 Pt F \'{'~= P1= p ~.::. Vm:u= _____ lbs i\lm,. = ______ ft-lbs l,.,JJ = ____ _ Use: "-JI t...X i _~( C-::. ?/s·') V,u= ----lbs M,n = ______ ft-lbs T= ______ m• ,x,, = c '2, · 1 2 ~ 2 1 r-·, 2. ') c s o +-6 r-) ::: 2... o 1 ~ r c i:- ,x12= P1= P2= "''"·"= ______ lbs ft-lbs lwy'~ = ______ m1 I/. \ L' se: \iJ \ 4 )( I C' ~ C C -l J V,11 = ____ lbs M,,1= _____ ft-lbs I = ______ tn• Qualls E ngineering Structural Engineering Services Pro1m: Sf g t-,e_ ~ t 'rt e C Engineer. ( G, ---=------- Sheer: _2_2_,_/ __ Joh# I 5 lli \ D:ite: V crtical Design Level: ~ I OOY D1 = s. o psf L·.·< = G S----psf LL = psf Membe r: F g ?> ---'--.:.:........::=----- F _,v, -t v ,, \( '1 H.1 = -'2. O ~jQ__ lbs R" :--.c "'2.o 6~o lbs Member: --'-~-:-l's:=---:-l~O=----- f' I ---::_1 v 2.o \( ,, '1 RL = 5 '2-I .f"o lbs R R::: s 2. I !:'"o lbs Member: F\3\ I -1,) I t t v '2 6 \( ,, '1 R,:.: ~ r-10 l!.>~ R,{ = 2 0 ~0 lbs Member: F (S I 2. v ,, I&' 1' RL = ll 100 lb~ RR= I I I & o lbs W1='Z.1.rh.C'?.0 +6.r)+lo 1 1r -117 2 f CF \X':= P1= P:= Vm"' = i'vlm,. = l «y·J = l 'sc:: 'v.J 14X 61 lbs V,n= fr-lbs M,11 = m• I= 1'" ~e..f.::ru(a e, W1 = lJ 2. . i;;-'/? ( '?. o +-6 1) -:. 2 0 I g P (.. f= \'<'2= P1= ~ ( I<'. G:; 1 x '2 :;: I I u 1 O 'I< Z :. '2 '2 u. () # CC -s/ g ~) - lbs ft-lbs in• Use:W\4 X-;"~ ((.-.:.1/f') Vma.~ = lbs V .i1 = _____ lbs Mnu., = ft-lbs M,11 = _____ ft-lbs I,.~·J = in• I = ------in• ~ t l Y'hrrc. c.. W1=1.'.?./2('2..o+1oo)f l 0°il.r--1~10 Pli:- W:= P,= P:= \.7 m:,x = t\'l,n.u = ln:~·d = lbs Va11= _____ lbs fr-lbs M,u = fr-lbs in~ r = ______ m' * .s ~" -Yl.L V (' .. IC. w,= (s-oh. ~ 7·12 ')CI r-t ?o)--+-1oi1 \ + & /1 ?.( 20+100) I 2 2 k Pt i:. W:= r;; oh .. c , ~ 4-2 o > + 1 o')(, r .-~ 1, 2-c , J -1-1 o J ) 11 o 6 r c. r-- P1= P2= \'ma..:= ____ _ l\1max = _____ _ lbs ft-lbs '"'-f'J = ------in• Use. 'v-.} V..:1= M,11= I = * ~('p ~ 'i. {1 () .f I ,~ I R" . )'A lbs ft-lbs U1' t Y' {..If C. C. Qualls Engineering Sheer· 23L Structural Engineering Services Proje..:t: g~'1\e ..Sh•fRt Job #: I 9 \4 I Engincn: CC, Dare: V crtical Design Level: Fl ooY D ; = 3o psf L1\ = psf LL = 6 (-psf :Member: E g I :S. s-+'2.0) -t J O 3 I' l F-'2... f/2 (..I t..J1 \~',= -------f \'\':= t P1= 3 1/2 P:= Use: )( \ 6 v r L I, '2. o· v V,na, = ~o3o lbs V.u= ( 0 6 <, O lbs '1 1 R, = l/010 lbs Mm,x = 2 '2. '2. I S' ft-lbs M,i= ?.736£, ft-lbs R,\ = ~ o ,0 lbs I ,.9·J = i '2.. ' in4 l = ii 9~ m• Member: \'</1 = W2= t t P1= P:= Use: I, \l,r.:u = lbs V,11= lbs '1 'I R, = lbs NI,,..,, = ft-lbs M,11= ft-lbs R,l = lbs lrc~'d = in4 I = in·' Member: \V1= \V/:= t t P,= P:= Use: I, \'max = lbs V,u= lbs 'I '1 Ri. =: lbs l\.lmu = ft-lbs M,u= ft-lbs R;t = lbs l,c~'d = in' l = in' Mc1nbcr: \'\",= W2= f t P,= " -~ •~t~: 1-;- ,f I, \,..m,, = lbs V,u = lhs 'I R1 = lbs ~fm,s = _ ft-lbs M .,11 = ft-lbs RR = lbs Irc~·J = tn 1 I= Ul-1 Qualls Engineering Structural Engineering Services Project: State Street Engineer: CG ------------ Glazing Calculations Colwnn (E} C,MIJ ~ALL - PER PLAN (E) SLAB ON i,AADE ~ t Wind = 21.1 psf (ASD) May use 0.7W for deflection checks 21.1 psf * 0. 7 = 14.Spsf See Enercalc printouts (next three pages) (N) 1>LAWl6 ~LL FER ARC,H Header Sheet: 24 ----- Job #: 19141 Date: \ ' ~ \_·~ (E) ~LL FOOTIN<; PER PLAN 'Qualls Engineering 4403 Manchester Ave, Suite 203 25 Printed 27 SEP 2019 11 34AM Steel Column File. C:ll.Jsefs\Fiy\Dropbox\Pr~ts\2019J0-1\191◄1-1\CAI.CUL-1\Enercalc\191◄1_State_Slreet -CG.EC6 . SOO-e c . ENERCALC, INC. 1983·2019, Build:12.19.8.30 . ,.,,.,. DESCRIPTION: Main Glazing Column Code References Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : ASCE 7-10 General Information Steel Section Name : HSS8x3x1/4 Load Resistance Factor • Overall Column Height 22.25 ft Top & Bottom Fixity Top Pinned, Bottom Fixed Analysis Method : Steel Stress Grade Fy : Steel Yield Brace condition for deflection (buckling) along columns : E : Elastic Bending Modulus Applied Loads 50 ksi 29,000.0 ksi Column self weight included : 384.590 lbs· Dead Load Factor AXIAL LOADS ... Roof: Axial Load at 22.250 ft, D = 1. 769, LR = 2.359 k Glazing Wall: Axial Load at 22.250 ft, D = 0.9830 k BENDING LOADS ... Wind: Lat. Point Load at 11.125 ft creating Mx-x, W = 3.846 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio = Load Combination 0.4390 : 1 +1 .20D+0.50Lr+W Location of max.above base At maximum location values are . Pu 0.9. Pn Mu-x 0.9 • Mn-x: Mu-y 0.9. Mn-y: PASS Maximum Shear Stress Ratio= Load Combination Location of max.above base At maximum location values are .. Vu : Applied Vn • Phi : Allowable 0.0 ft 4.943 k 36.904 k -16.045 k-ft 43.125 k-ft 0.0 k-ft 21.375 k-ft 0.03454 : 1 + 1. 20D+O. 50Lr+W 0.0 ft 2.644 k 76.551 k X-X (width) axis: Unbraced Length for buckling ABOUT Y-Y Axis = 22.25 It, K = 0.80 Y-Y (depth) axis: Fully braced against buckling ABOUT X-X Axis Service loads entered Load Factors will be applied for calculations Maximum Load Reactions .. Top along X-X Bottom along X-X Top along Y-Y Bottom along Y-Y Maximum Load Deflections ... Along Y-Y in at for load combination : Along X-X in at for load combination : k k k k ft above base ft above base 'Qualls Engineering 4403 Manchester Ave, Suite 203 26 Printed 27 SEP 20 I 9 11 34AM Steel Beam File• C:\Users\Fry\Dropbox\Pr~ts\2019J0-1\19141--1\CAI.CUL-1\Enercalc\19141_State_Slreet -CG.EC6 . Soltwarec . ENERCALC, INC. 1983-2019, Build:12.19.8.30 . , .. , ... DESCRIPTION: HSS Glazing Beam CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-10 Material Properties Analysis Method: Load Resistance Factor Design Beam Bracing : Completely Unbraced Bending Axis : Minor Axis Bending W 0 .148 W14x22 Span = 9 . 750 rt Fy: Steel Yield : E: Modulus: 50.0 ksi 29,000.0 ksi . . Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self wei(lht NOT internally calculated and added Uniform Load: W = 0.01480 ksf, Tributary Width= 10.0 ft. (Wind) DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Mu : Applied Mn • Phi : Allowable Load Combination Location of maximum on span Span If where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Overall Maximum Deflections Load Combination Span WOnly Vertical Reactions Load Combination Support 1 Overall MAXimum 0.722 Overall MINimum 0.325 +0.60W 0.433 +0.450W 0.325 WOnly 0.722 0.107: 1 W14x22 Maximum Shear Stress Ratio = Section used for this span Vu : Applied Max."." Defl 0.1489 Support 2 0.722 0.325 0.433 0.325 0.722 1. 759 k-ft 16.463 k-ft WOnly 4.875ft Span # 1 0.149 in Ratio= 0.000 in Ratio= 0.089 in Ratio= 0.000 in Ratio = Location in Span 4.903 Vn • Phi : Allowable Load Combination Location of maximum on span Span # where maximum occurs 785 >=360. 0 <360.0 1309 >=240. 0 <240.0 Load Combination Support notation : Far lelt is #1 Design OK 0.007: 1 W14x22 0.7215 k 100.50 k WOnly 0.000 ft Span # 1 Max. "+" Den Location in Span 0.0000 0.000 Values in KIPS 'Qualls Engineering 4403 Manchester Ave, Suite 203 27 Printed 27 SEP 20 19 11 34AM Steel Beam File = C:\Users\F ry\Dropbox\J'r~ts\2019JO-1119141-1\CALCUL -1\Enercalcl 1914 l_Siate_Street -CG.EC6 . Sdtware c ENERCALC, INC. 1983-2019, Build:12.19.8.30 . , ..... . DESCRIPTION: HSS Glazing Header CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-10 Material Properties Analysis Method : Load Resistance Factor Design Beam Bracing : Beam is Fully Braced against lateral-torsional buckling Bending Axis : Major Axis Bending WO 08288 HSS8x3x1/4 Span = 9 .750 ft Fy : Steel Yield: E: Modulus: 50.0 ksi 29,000.0 ksi -. Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weiQht NOT internally calculated and added Uniform Load: W = 0.01480 ksf, Tributary Width= 5.60 ft, (Wind) DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Mu : Applied Mn • Phi : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Overall Maximum Deflections Load Combination Span WOnly 1 Vertical Reactions Load Combination Support 1 Overall MAXimum 0.404 Overall MINimum 0.182 +0.60W 0.242 +0.450W 0,182 WOnly 0.404 0.023: 1 HSS8x3x1/4 0.985 k-ft 43.125 k-ft WOnly 4.875ft Span# 1 Maximum Shear Stress Ratio = Section used for this span Vu : Applied Max."." Defl 0.0164 Support 2 0.404 0.182 0.242 0.182 0.404 0.016 in Ratio = 0.000 in Ratio= 0.010 in Ratio= 0.000 in Ratio= Location in Span 4.903 Vn * Phi : Allowable Load Combination Location of maximum on span Span # where maximum occurs 7, 115 >=360. 0 <360.0 11858 >=240. 0 <240.0 Load Combination Support notation : Far left is #1 Design OK 0.004 : 1 HSS8x3x1/4 0.4040 k 91 .861 k WOnly 0.000 fl Span# 1 Max. "+ Defl Location in Span 0.0000 0.000 Values in KIPS Qualls Engineering Structun.l Engineering Services Canopy Beams I l (CANT.) (N) H554x4x% 5TL. COL. See E nercalc printouts (next 3 sheets) Project: State Street Engineer: ....:C::....G:::...._ _______ _ 14'-7" Sheet: 28 ---- Job#: 19141 Date: Trib Beam (N) H~ 5Ti Edge Beam 'Qualls Engineering 4403 Manchester Ave, Suite 203 29 Printed 27 SEP 2019 12 OSPM Steel Beam File= C:\Users\Fry\Dropbox\Projects\2019J0-1\191◄1--1\CAI.CUL-1\Ene«:alc\191◄1_State_Sneet • CG.EC6 . Software c . ENERCALC, INC. 1983-2019, Build:12.19.8.30 . 1,11'· • DESCRIPTION: Canopy Edge Beam CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-10 Material Properties Analysis Method: Load Resistance Factor Design Beam Bracing : Beam is Fully Braced against lateral-torsional buckling Bending Axis : Major Axis Bending Fy : Steel Yield : E: Modulus: 50.0 ksi 29,000.0 ksi • • .-------------.----------"D:..,,(.::.Oc..:.1_,:6.:::8.::.8.._,)0/='Lr'-'-(O.::.•,o,2ce,2.::.5 .::.0 ),__ _______ 0...-------------.,v HSS 1 2x4x5/16 Spa n = 14 .50 ft HSS12x4x5/16 Span = 11 .60 ft HSS 12x4x5/16 Span= 14.580 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weiqht NOT internally calculated and added Loads on all spans ... Uniform Load on ALL spans: D = 0.0150, Lr = 0.020 ksf, Tributary Width = 11.250 ft DESIGN SUMMARY Maximum Bending Stress Ratio = 0.504: 1 Section used for this span HSS 12x4x5/16 Mu : Applied 59.133 k-ft Maximum Shear Stress Ratio = Section used for this span Vu : Applied Mn• Phi : Allowable 117.375 k-ft Load Combination + 1.20D+ 1.60Lr +0.50L + 1.60H Location of maximum on span 14.500ft Span # where maximum occurs Span # 1 Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Overall Maximum Deflections 0.975 in -0.064 in 1.706 in -0.112 in Ratio= Ratio = Ratio= Ratio= Load Combination Span Max."." Den Location in Span +D+Lr+H 1 1.7062 0.000 2 0.0000 0.000 +D+lr+H 3 0.0992 7.290 Vn • Phi : Allowable Load Combination Location of maximum on span Span # where maximum occurs 356>=240. 2, 178 >=240. 204 >=180. 1245 >=180. Load Combination +D+Lr+H Vertical Reactions Support notation: Far left is #1 Load Combination Support 1 Support 2 Support 3 Support 4 Overall MAXimum 11.597 1 .523 2.898 Overall MINimum 2.982 0.392 0.745 +D+H 4.970 0.653 1.242 +D+L+H 4.970 0.653 1.242 +D+Lr+H 11.597 1.523 2.898 +D+S+H 4.970 0.653 1.242 +D+O. 750Lr+0.750L +H 9.940 1.305 2.484 +D+O. 750L +0. 750S+H 4.970 0.653 1.242 +D+0.60W+H 4.970 0.653 1.242 +D+0.70E+H 4.970 0.653 1.242 +D+O. 750Lr +0. 750L +0.450W+H 9.940 1.305 2.484 +D+O. 750L +0. 750S+0.450W +H 4.970 0.653 1.242 +D+0.750L +0. 750S+0.5250E +H 4.970 0.653 1.242 +0.60D+0.60W+O GOH 2.982 0.392 0.745 +0.600+0. 70E +0.60H 2.982 0.392 0.745 DOnly 4.970 0.653 1.242 Design OK 0.048: 1 HSS 12x4x5/16 8.411 k 174.850 k + 1.20D+ 1.60Lr+0.50L+ 1.60H 14.500 ft Span # 1 Max."+" Deft Location in Span 0.0000 0.000 -0.1118 4.563 0.0000 4.563 Values in KIPS 'Qualls Engineering 4403 Manchester Ave. Suite 203 30 Printed 27 SEP 2019 12 10PM Steel Beam File• C:\Users\Fry\Dropbox\Pr~ts\2019J0-1\191◄1-1\CALCUL-1\Enercalc\191◄1_State_Slreet -CG.ECG . Salware c . I ENERCALC, INC. 1983-2019, Build:12.19.8.30 . ···•··· DESCRIPTION: Canopy Trib Beam CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-10 Material Properties Analysis Method: Load Resistance Factor Design Beam Bracing : Beam is Fully Braced against lateral-torsional buckling Bending Axis : Major Axis Bending D 0.195 Lr 0.26 HSS 12x4x5/16 Span= 22.580 rt F y : Steel Yield : E: Modulus: 50.0 ksi 29,000.0 ksi . . . Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weiqht calculated and added to loadinq Uniform Load : D = 0.0150, Lr = 0.020 ksf. Tributary Width = 13.0 ft, (Canopy) DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Mu : Applied Mn• Phi : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Overall Maximum Deflections Load Combination Span +D+Lr 1 Vertical Reactions Load Combination Support 1 Overall MAXimum 5.496 Overall MINimum 1.537 DOnly 2.561 +O+Lr 5.496 +0+0.750Lr 4.763 +0.600 1.537 Lr Only 2.935 0.374: 1 HSS12x4x5/16 43.861 k-ft 117.375 k-ft + 1.200+ l .60Lr 11.290ft Span # 1 Maximum Shear Stress Ratio = Section used for this span Vu: Applied Max."-" Den 0.6850 Support 2 5.496 1.537 2.561 5.496 4.763 1.537 2 935 0.366 in Ratio= 0.000 in Ratio = 0.685 in Ratio= 0.000 in Ratio= Location in Span 11.355 Vn • Phi : Allowable Load Combination Location of maximum on span Span # where maximum occurs 740 >=240. 0 <240.0 396 >=180. 0 <180.0 Load Combination Support notation : Far left is #1 Design OK 0.044: 1 HSS12x4x5/16 7.770 k 174.850 k + 1.20D+ l .60Lr 0.000 ft Span If 1 Max. • +" Dell Location in Span 0.0000 0.000 Values in KIPS 'Qualls Engineering 4403 Manchester Ave, Suite 203 31 Printed 27 SEP 2019 12 12PM Steel Beam File 2 C:\Users\F ry\Dropbox\Projects\2019J0-1 \19141 •-1\CALCUL -1\Enercalc\ 19141_State_Slreet • CG. EC6 . Software c ENERCALC, INC. 1983-2019, Build:12.19.8.30 . ,.,, ... DESCRIPTION: Cant Beam CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-10 Material Properties Analysis Method: Load Resistance Factor Design Beam Bracing : Completely Unbraced Bending Axis : Major Axis Bending 0 (0.3) Lr(0.4) . F y : Steel Yield : E: Modulus: 50.0 ksi 29,000.0 ksi • ~~J,.._~--HSS 12x6x15/8 Span= 6.~o n Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weiqht NOT internally calculated and added Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 20.0 ft, (Canopy) DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Mu : Applied Mn * Phi : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Overall Maximum Deflections Load Combination +D+Lr Vertical Reactions Load Combination Overall MAXimum Overall MINimum D Only +D+Lr +D+0.750Lr +0.60D Lr Only Span Support 1 4.550 1.170 1.950 4.550 3.900 1.170 2.600 0.082: 1 HSS12x6x5/8 21.125 k-ft 258.000 k-ft + 1.20D+ 1.60Lr 0.000ft Span# 1 Maximum Shear Stress Ratio = Section used for this span Vu : Applied Max."." Defl 0.0289 Support 2 0.017 in Ratio= 0.000 in Ratio= 0.029 in Ratio= 0.000 in Ratio= Location in Span 6.500 Vn * Phi : Allowable Load Combination Location of maximum on span Span # where maximum occurs 9,433 >=240. 0 <240.0 5391 >=180. 0 <180.0 Load Combination Support notation : Far lelt is #1 Design OK 0.020: 1 HSS 12x6x5/8 6.50 k 321 .803 k + 1.20D+ 1.60Lr 0.000 ft Span# 1 Max."+" Dell 0.0000 Values in KIPS Location in Span 0.000 Qualls Engineering Structural Engineering Services Project: State Street Engineer: ...;::C:....::G:__ _____ _ Canopy Beams CV f--6'-6" -i L l lll lll ll V "--(------ CantBeam_/ D+L Gravity load = (1 Spsf + 20pst)(20ft) = 700plf P = 700plf(6.Sft) = 4,SSOlbs M = 4,550lbs(3.25ft) = 14,788 ft-lbs 0.6D+0.7E P = 0.6(15pst)(20ft)(6.5) = 1,170 lbs M(dead) = 1, 170lbs(3.25ft) = 3,803 ft-lbs V = 0.114(15pst)(421ft2)/4 columns= 180lbs M(seismic) = 180lbs(11ft) = 1,980 ft-lb s ~M = 3,803 + 1,980 = 5,783 ft-lbs See Enercalc printout for pole footing design. T 0 I Sheet: 32 --- Job #: 19141 Date: 'tlualls Engineering \ 4403 Manchester Ave, Suite 203 33 Printed 27 SEP 20 19 I 25PM Pole Footing Embedded in Soil File= C:\Users\Fry\Dropbox\Prqectsl2019J0-1119141--1\CALCUL-1\Enercalc\19141_Slale_Slreel • CG.EC6 . .. ,, ... DESCRIPTION: Pole Footing Code References Calculations per IBC 2015 1807.3, CBC 2016, ASCE 7-10 Load Combinations Used : ASCE 7-10 General Information Pole Footing Shape Pole Footing Width ............ . Rectangular 36.0 in Calculate Min. Depth for Allowable Pressures No Lateral Restraint at Ground Surface Sdlwarec . ENERCALC, INC. 1983-2019, Build:12.19.8.30 . • Allow Passive ................. . Max Passive .................. . 250.0 pcf 1,500.0 psi Point Load Controlling Values Governing Load Combination : +D+Lr Lateral Load Moment NO Ground Surface Restraint Pressures at 1/3 Depth Actual Allowable Minimum Required Depth Footing Base Area Maximum Soil Pressure A lied Loads Lateral Concentrated Load (kl D: Dead Load Lr : Roof Live L : Live S: Snow W:Wind E : Earthquake H : Lateral Earth Load distance above ground surface 0.5760 k 0.7680 k k k k 0.0 k k 11.0 ft Load Combination Results Load Combination DOnly +D+Lr +D+0.750Lr +0.600 1.344 k 14.784 k-ft 446.851 psi 447.935 psi 5.50 It 9.0 1t·2 0.5056 ksf Lateral Distributed Loads (kin TOP of Load above ground surface BOTTOM of Load above ground surface Forces Ill> GrOIJ'ld Sooace Loads -(k) Momens -(ft-k) 0.576 6.336 1.344 1.152 0.346 14.784 12.672 3.802 kilt kilt kilt kilt kilt kilt kilt ft rt Soil Surface Vertical Load (k) 1.950 k 2.60 k k k k k k Required Oeph-(11) 4.00 5.50 5.13 3.38 Prffilft 311/3 Oeph Soil Increase Actual . (psi) Alow-(psl) Fac!Or 327.4 328.1 1.000 446.9 447.9 1.000 421.5 423.4 1.000 271.3 273.4 1.000 • ' Qualls Engineering Structutal Engineering Services Stud Checks Project: State Street Engineer: --"C'-"G'-------- Sheet: -=3'---'4'-------- J ob#: 19141 Date: Controlling conditions are along grid H (high axial load, and wind) and grid 5 (tall framing with wind) Grid H: ASD floor load = 30psf + 65psf = 95psf Axial load= (95psf)(44.58ft/2)(16/12)ft = 2,823 lbs/stud Moment (Wind)= (21.1psf)(16/12)ft(13.Sft)' / 8 = 641 ft-lbs Use 600S162-54@ 16" o.c. -see SSMA table on next page (3,330lbs allowable) Grid 5: For deflection, code allows 0.7 of ASD wind forces (fable 1604.3, note f) 21.1psf(0.7) = 14.Spsf Limiting stud height for 600S162-54@ 16" o.c. is 23'-9" for 15psf (L/240) Studs are 19'-8" tall at vaulted portion, so studs OK 20 psf Lateral Load 3IOl1G ml1ff --Wal '= T 331111 501111 331111 501111 331111 501111 331111 501111 33 43 54 .. 33 43 54 .. 33 43 54 .. 33 43 54 .. 12 1.16 1.89 3.36 4.46 0.91 1.53 2.17 3.80 1.23 1.99 3.55 4.76 1.55 2.56 4.49 6.01 8 16 0.90 1.62 3.11 4.21 0.67 1.28 2.54 3.56 0.98 1.72 3.30 4.50 1.27 2.27 4.20 5.72 24 0.43' 1.11' 2.64 3.72 0.241 0.81' 2.11 3.10 0.50' 1.21 2.82 4.01 0.74 4 1.71 3.65 5.18 12 0.90 1.57 2.91 3.92 0.68 1.26 2.43 3.37 0.97 1.68 3.12 4.23 1.25 2.19 3.94 5.34 9 16 0.60' 1.26 2.62 3.62 0.411 0.97' 2.16 3.08 0.67' 1.36 2.82 3.92 0.92 1.85 3.60 5.00 24 0,69 I 2.08' 3.06 0.44' 1.661 2.55' 0.13 I 0.781 2.27' 3.34 0.32' 1.21 • 2.97 4.37 12 0.64 ' 1.25 2.45 3.37 0.46' 0.99 ' 2.07 2.91 0.71 ' 1.36 2.67 3.66 0.95 1.82 3.38 4.65 10 16 0.32 ' 0.91 ' 2.14' 3.03 0.16 I 0.66 ' 1.77 ' 2.59 0.38' 1.01' 2.34 3.32 0.59' 1.43' 3.00 4.27 24 0.29 ' 1.561 2.43 I 1.22 ' 2.011 0.38 ' 1.74 l 2.69' 0.74' 2.32' 3.58 ' 12 0.181 0.67 ' 1.62' 2.33 • 0.48' 1.36 I 2.02' 0.24 ' 0.76' 1.81 ' 2.58' 0.41 1 1.11' 2.32' 3.32 12 16 0.30 1 1.29' 1.971 0.131 1.04 ' 1.671 0.381 1.45' 2.20' 0.69' 1.921 2.91' 24 -0.70 I 1.351 0.481 1.062 0.84 1 1.55' 1.21 I 2.19 I 12 0.22 2 1.00' 1.54 ' 0.82 ' 1.31' 0.29 ' 1.14 I 1.73' 0.54 1 1.49 ' 2.281 14 16 0.682 1.201 0.50 1 0.97' 0.79' 1.36' 0.121 1.10' 1.88 ' 24 0.13 1 0.60 1 0.39' 0.21' 0.73 ' 0.43 1 1.18' 12 0.57' 0.98 1 0.42 1 0.801 0.66' 1.121 0.12 I 0.91 1 1.531 16 16 0.26' 0.66 1 0.131 0.491 0.34 1 0.77 1 0.54 1 1.15' 24 0.111 -0.19' 0.50 1 20 psf Lateral Load 4008137 4008112 .,.. IRl1G Wd = T 331111 501111 33kal 50kal 331111 501111 331111 501111 33 43 54 ea 33 43 54 .. 33 43 54 .. 33 43 54 .. 12 1.06 1.74 3.14 4.41 1.42 2.25 4.04 5.57 1.76 2.88 5.10 6.97 1.93 2.95 5.22 7.06 8 16 0.83 1.50 2.92 4.18 1.17 1.99 3.79 5.31 1.48 2.60 4.82 6.69 1.74 2.77 5.05 6.89 24 0.40' 1.04 2.50 3.72 0.70 1.50 3.32 4.81 0.97 2.06 4.28 6.14 1.35 2.41 4.70 6.55 12 0.84 1.49 2.83 4.07 1.17 1.95 3.64 5.08 1.47 2.53 4.59 6.36 1.75 2.77 5.03 6.90 9 16 0.57 ' 1.20 2.56 3.77 0.87 1.64 3.34 4.76 1.15 2.19 4.25 6.01 1.50 2.54 4.80 6.67 24 -0.67 ' 2.06 3.21 0.331 1.07' 2.78 4.16 0.55' 1.56 3.61 5.35 1.03 2.09 4.36 6.23 12 0.62 ' 1.22 2.49 3.62 0.90 1.64 3.21 4.54 1.18 2.17 4.05 5.69 1.54 2.56 4.76 6.69 10 16 0.31' 0.89' 2.18 3.28 0.57' 1.29 2.87 4.17 0.81 ' 1.78 3.66 5.29 1.24 2.28 4.48 6.40 24 0.301 1.611 2.65' 0.64 1 2.24 1 3.48 0.151 1.07' 2.94 4.54 0.89 1.74 3.94 5.85 12 0.19 I 0.70 1 1.78' 2.67 0.41 ' 1.03 I 2.33 • 3.38 0.61 1 1.44' 2.96 4.31 1.08 2.07 4.10 5.91 12 16 0.32 I 1.42' 2.271 0.62' 1.94' 2.96' 0.20 1 0.991 2.52' 3.84 0.70 ' 1.69 3.72 5.51 24 0.79' 1.58 1 1.25 ' 2.201 0.20 1 1.73 I 3.001 0.99' 3.01 4.76 12 0.25 2 1.15' 1.82 ' 0.50' 1.561 2.351 0.141 0.81 ' 2.01' 3.05' 0.61 ' 1.53 3.34 4.97 14 16 0.79 ' 1.42 2 1.161 1.92' 0.35' 1.57' 2.58' 0.17' 1.08 1 2.88' 4.48 24 0.16' 0.73 ' 0.48 1 1.18 ' 0.79 2 1.76' 0.26' 2.05' 3.59' 12 0.67 2 1.171 0.98' 1.58' 0.32' 1.301 2.101 0.18' 1.00' 2.57' 3.97 16 16 0.32 ' 0.80 2 0.60 ' 1.17 2 0.87' 1.65 1 0.51 ' 2.071 3.43' 24 0.15 ' 0.48 1 0.14 1 0.89 ' 1.192 2.481 20 psf Lateral Load IGOll137 IGOll112 -Wal ~ T 331111 50kal 33kal 50kal 33kal 501111 33 43 54 ea 97 33 43 54 ea 97 33 43 54 ea 17 12 1.42 2.17 3.53 4.77 7.30 2.00 3.02 5.25 7.10 11.06 2.43 3.86 7.01 9.55 15.23 8 16 1.27 2.02 3.40 4.65 7.20 1.82 2.85 5.10 6.95 10.91 2.25 3.66 6.81 9.36 15.04 24 0.97 1.73 3.15 4.40 6.99 1.47 2.53 4.79 6.65 10.61 1.88 3.27 6.42 9.00 14.67 12 1.29 2.04 3.41 4.66 7.21 1.85 2.87 5.11 6.96 10.91 2.26 3.65 6.73 9.25 14.84 9 18 1.10 1.85 3.25 4.50 7.07 1.62 2.66 4.91 6.76 10.72 2.02 3.40 6.48 9.01 14.60 24 0.73 1.48 2.93 4.18 6.80 1.18 2.25 4.51 6.38 10.34 1.56 2.91 5.98 8.54 14.12 12 1.15 1.90 3.28 4.53 7.09 1.67 2.71 4.94 6.79 10.74 2.06 3.41 6.41 8.89 14.37 10 16 0.92 1.67 3.08 4.33 6.92 1.40 2.45 4.69 6.55 10.50 1.77 3.11 6.10 8.59 14.06 24 0.47 1.22 2.69 3.94 6.58 0.86 1.94 4.20 6.06 10.01 1.22 2.51 5.49 8.01 13.47 12 0.82 1.56 2.97 4.21 6.80 1.25 2.28 4.48 6.37 10.29 1.60 2.86 5.63 8.00 13.16 12 16 0.50 1.24 2.68 3.92 6.54 0.88 1.92 4.11 6.00 9.91 1.22 2.44 5.19 7.58 12.72 24 0.63' 2.13 3.36 6.03 0,19 ' 1.24 3.43 5.30 9.18 0.50' 1.66 4.37 6.17 11.86 12 0.46' 1.17 2 59 3.81 6.42 0.79 1.78 • on 5.58 9.63 1.11 2.24 4.71 6.92 11.64 14 16 0.76 ' 2.21 3.42 6.05 0.35 ' 1.33 • Wj) 5.10 9.09 0.64 ' 1.73 4.18 6.38 11.06 24 0.01 ' 1.50' 2 68 1 5.35 0.52 3 4.21 8.09 0.79' 3.19' 5.39 9.97 12 0.76 ' 2.15' 3.33 5.92 0.35' 1.26' 3.03 4.64 8.21 0.62' 1.62 3.76 5.75 9.94 16 16 0.28 ' 1.691 2.84' 5.44 0.75' 2.52' 4.08 7.58 0.101 1.04 1 3.16 • 5.13 9.25 24 0.85' 1.95' 4.56 1 1.60' 3.09 1 6.44' -2.09' 4.03' 8.00 If no note, o'eflectlon mt!t!ts l/7.l0 0eflectlon m~ets l/1.l0 'Deflection meets l/.l40 'Oeflectlon meets l/J60 'Oeflectlon meets l/600 hctlon A'&r!c" lpef 11pef 20pef L/120 U240 L/3IO U240 L/3IO UIOO U240 LIMO UIOO 12 27' 4• 21' 8' 18' 11' 18' 11' 14' 9• 12' 6" 15' 4' 13' 5" 11' 4• 400$137-43 33 18 24' 10' 19' 8' 17' 2' 15'4" 13'5" 11'4" 13' 4' 12' 2· 10' 4' 24 21' 8' 17' 2' 15'0" 12' 7• 11' 9• 9' 11' 10' 10' 10' 8' 9'0' 12 28' 7· 22' 8' 19' 10 17'9" 15'6' 13' 1· 16' 1' 14' 1· 11' 10' 400$182-43 33 16 26' o· 20· 1· 18'0" 16' 1· 14' 1· 11' 10· 14'4' 12'9" 10' g• 24 22' 8' 18'0' 15'9' 13'6" 12' 3' 10'4" 11'9' 11' 2· 9' 5' 12 30' 2' 23' 11' 20' 11' 18'8' 16'4' 13'9' 17'0' 14' 10" 12'8' 400S200-43 33 16 27' 5• 21'9' 19'0' 17' o· 14• 10· 12· 8' 15'4' 13'8' 11' 4' 24 23· 11· 19• o· 18' 7' 14'8' 13· o· 10· 11· 12'7' 11'9' 9' 11' 12 29' 3• 23' 2' 20' 3· 18' 1· 15' 10· 13' 4' 16'6' 14'5' 12' 2· 400S137-54 50 16 26' 7" 21' 1' 18' 5' 16'6' 14' 5' 12' 2' 15'0' 13' 1' 11'0' 24 23' 2· 18' 5• 16' 1' 14• 5• 12'7' 10' 7' 13' 1' 11'5' 9' 8' 12 30' 8' 24'4' 21' 3' 19'0' 16' 7' 14'0' 17' 3' 15' 1· 12' 9' 400$162-54 50 16 27' 10' 22' 1' 19'4' 17'3' 15' 1' 12' 9' 15'8' 13'8' 11' 7' 24 24'4' 19' 4' 16' 10' 16' 1' 13'2' 11' 1' 13'8' 12'0' 10' 1' 12 32' 4' 25' 8' 22· 5• 20' 1' 17'6' 14'9' 18' 3' 15' 11' 13' 5' 400S200-54 50 16 29· 5• 23' 4' 20' 5' 18' 3' 15' 11' 13' 5' 16' 7' 14'6' 12' 2' 24 25' 8' 20· s· 11· 10 15' 11' 13' 11' 11' 9' 14'6' 12' 8' 10'8' 12 31• 3• 24' 10· 21· 8' 19' 4' 16' 11· 14' 3' 17' 7' 15'5' 13'0' 400S137-68 50 16 28' 5• 22· 1· 19' 8' 17' 7• 15'5' 13'0' 16'0' 14'0' 11' 9' 24 24' 10' 19' 8' 17' 2' 1s· 5• 13'5' 11' 4' 14• o· 12' 2' 10'4' 12 32· 10· 26' o· 22· 9• 20'4' 17' 9' 15• o· 18'6' 16' 2' 13' 7' 400S162-66 50 16 29· 10· 23• 8' 20· 8' 18'6' 16'2' 13' 7' 16'9' 14'8' 12'4' 24 26' o· 20· 8' 18' 1' 16'2' 14' 1' 11' 11' 14' 8' 12' 10· 10' 10' 12 34' 8' 27' 8' 24'0' 21'6' 18' 9' 15' 10 19'6' 17' 1' 14'5' 400S200-68 50 16 31' 6' 25• o· 21· 10· 19'6' 17' 1' 14• s· 17'9' 15'6' 13' 1' 24 27' 8' 21' 10· 19' 1' 17' 1' 14' 11' 12' 7' 15'6' 13'6' 11'5' 12 33' 8' 26' 9' 23'4' 19'7' 18' 3' 15• 5• 16' 11"e 16' 7'e 14' o· 550S162-33 33 16 29'4' 24'4" 21' 3' 16' 11•e 16' 7'e 14' o· 14' 8'e 14' 8'e 12· 8'e 24 24'0" 21' 3" 18'6' 13' 10"e 13' 10'e 12' 3"e 12' o·, 12· o·a 11· 1·, 12 36' 8' 29' 1· 25• 5• 22' 9' 19' 10' 16' 9' 20'8' 18' 1' 15' 3' 550S162•43 33 18 33' 4' 26' 5' 23' 1' 20· 8' 18' 1' 15'3" 18' 1· 18'5' 13' 10' 24 29' 1' 23' 1' 20' 2' 17' 1' 15'9' 13' 4' ~4' 10'1 14' 4'1 12' 1• 12 39' 4' 31' 3' 27' 3' 24• 5• 21' 4' 18' o· 22'2' 19'4' 16'4" 550S162-54 50 16 35•9• 28' s· 24'9' 22' 2· 19' 4' 16'4' 20' 2' 17' 7' 14' 10' 24 31' 3' 24' 9' 2r 8" 19' 4' 18' 11' 14' 3' 17' 7• 15'4' 13· o· 12 42'2' 33'6' 29'3' 26' 2' 22' 10' 19' 3• 23'9' 20'9' 17'6' 550S162-68 50 16 38'4' 30' 5' 26' 7' 23' 9· 20' 9' 17' 6' 21' 7' 18' 10' 15' 11' 24 33'6' 26' 7' 23' 3' 20'9' 18' 2' 15' 3' 18' 10· 16'6' 13' 11' 12 33• o· 21· 8' 24' o· 19' 1' 18' 9' 15' 10 16' 6'e 16' 6'e 14' 4' 600$137-33 33 16 28' 7' 24' 11' 21' 10 16' s·e 16' 6'e 14' 4' 14' 4'e 14' 4'1 13' 1·, 24 23' 4' 21' 9' 19' 1' 13' 6'e 13' 6'8 12' 7'1 11· 8'e 11· 8'e 11· 5'e 12 35' 6' 28' 8' 25• o· 20' 6'1 19' 8' 16' 8' 17' 9'e 17' 9'1 15' o· 600$162·33 33 16 30• 9· 28' o· 22· 9· 17' 9'e 17' 9'e 15' o· 15' 5'1 15' 5"e 13' 7'8 24 25' 1' 22' 9' 19' 10 14' s·e 14' 6'1 13' 1·e 12' 7'1 12' 7"1 11' 11·1 12 37' 11' 30' 1' 26' 3• 21' 10"e 20' s·e 17' 4' 18' 11'e 18' 8'e 15' 9'8 ~00S200-33 33 16 32' 10' 27' 4' 23' 10' 18'11'e 18' 8'e 15' 9'1 16' 5'1 16' 5'e 14' 3'e 24 26' 9' 23' 10' 20' 10' 15' 6'e 15' 6'e 13' 9"e 13' 5'e 13' 5"e 12' 6'e 12 37' 8' 29' 11' 26' 2' 22· 11· 20· 5· 17' 3' 19' 10' 18' 6' 15'8' 600S137-43 33 16 34' 3' 27' 2' 23' 9• 19' 10' 18' 6' 15' 8' 17' 2' 16' 10' 14' 2' 24 28' 1' 23' 9' 20' 9' 16' 2' 16'2' 13' 8' 14· 0•1 14' 0'8 12· 5• 12 39' 4' 31' 2' 27' 3' 24' 4' 21' 3· 17' 11' 21' 11' 19' 4' 16'4' 6005162-43 33 16 35' 9• 28' 4• 24' 9' 21' 11· 19'4" 16' 4' 19'0" 17' 7" 14' 10· 24 31' 1· 24' 9' 21' 8' 1711'8 16' 11' 14' 3' 15' 8'e 15' 4'e 12' 11• 12 41'3' 32'9' 28' 7' 25'7" 22' 4' 18' 10' 22' 8' 20' 4' 17' 2' ~005200·43 33 16 37' e· 29· s· 25· o· 22' 8' 20' 4' 17' 2' 19'7'8 18' 5· 15'7' 24 32· o· 25• o· 22· 9• 18' 8'1 11· 9•, 1s· o· 16' 0·1 16' o·, 13• 1·, 12 40' 5• 32• 1· 28' o· 25' 1' 21' 11' 18' 5' 22' 9' 19' 11· 16' 9' 600S137-54 50 16 36' 9' 29' 2· 25' 6' 22' 9' 19' 11' 16' 9' 20' 8' 18' 1' 15' 3' 24 32' 1' 25' 8' 22' 3' 19' 11· 17' 4· 14· 3· 18' 1· 15'9' 13' 4' 12 42· 2· 33· 5· 29'3' W.:' 10· 19' 3· 23' 9' 20' 9' 17' 6' 600S162-54 50 16 38' 4' 30' 5' 26' 7J 0'9' 17' 6' 21' 7' 18' 10' 15' 11' 24 33' 6' 26' 7' 23' 3' 8' 1' 15' 3' 18' 10' 16' 6' 13' 11' 12 44' 4· 35' 2· 30' 9' ~00S200-54 50 16 40• 3• 32• o· 2r 11· 24 35' 2' 27' 11' 24' 5' 12 43' 4• 34' 4• 30' o· 800S137-68 50 16 39' 4' 31' 3' 27' 3' 24 34' 4' 27' 3' 23' 10 12 45' 3· 35' 11' 31' 4· 600$162-68 50 16 41' 1' 32'7' 28' 6' 24 35' 11· 28' 6' 24' 11· ·e • web stiffeners required ar ends. t!l' Table Notes on page ZS. ,. 21· 6' 24· o· 20' 3' 24' 11· 2r 10· 18' 5• 24' 11· 21' 10' 18' 5' 22· 8' 19• 10· 16' s· 21' 10' 19' 1' 16' 1' 19' 10' 17' 4' 14' 7' 26' 10' 23' 5' 19'9' 24'5' 21'4' 18'0" 24• 5• 21'4' 18' o· 22' 2· 19'4' 16'4' 21' 4' 18' 7' 15' 8' 19' 4' 16' 11' 14' 3' 28' o· 24' 6' 20' 8' 25· s· 22'3' 18'9" 25' 6' 22' 3• 18'9' 23' 2· 20' 2· 17' 1' 22' 3' 19' 5' 15· s· 20' 2· 17' 8' 14' 11' 21pef U240 L/3IO ueoo 13'9' 12' 6" 10'6' 11' 11· 11' 4• 9' 7• 9'9' 9•9• 8'4' 14' 10· 13' 1' 11'0' 12· 10· 11· 10· 10· o· 10'6' 10'4' 8'9" 15'9' 13'9' 11' 7' 13' 9' 12'8' 10'7' 11'3'e 10•11· 9' 3' 15' 3' 13'4' 11' 3• 13' 11' 12' 2' 10' 3' 12' 2' 10' 7' 8' 11· 16'0' 14'0' 11'10' 14' 7' 12' 9' 10' 9' 12'9' 11' 1' 9' 4' 16' 11" 14'9' 12'6" 15' 4' 13'5' 11'4" 13'5' 11'9' 9' 11" 18'4' 14' 3' 12· o· 14• 10· 13• o· 10· 11· 13' o· 11'4' 9' 7' 17' 2' 15'0' 12' 8' 15' 7' 13' 7' 11'6' 13'7' 11' 11' 10'0' 18' 1' 15' 10· 13' 4' 16'6' 14• s· 12' 2· 14' 5' 12'7" 10'7' 15' 2'e 15' 2"e 13' O'e 13' 2·e 13' 2·e 11' 9'e 10' 9'e 10' 9'e 10' 4'e 18' 9' 16' 9' 14'2' 16' 3'e 15' 3' 12· 10· 13' 3'e 13' 3'e 11' 3'1 20' 7• 18'0' 15'2' 18'8" 16'4' 13'9' 16'4' 14' 3· 12'0' 22' 1' 19'3' 16' 3' 20'0' 17'6' 14'9' 17'6' 15' 3' 12' 11' 14' 9"e 14' 9'e 13' 4"e 12'10"8 12'10"e 12' 1·e 10' 5'8 10' 5'e 10' 5'e 1S11"e 1S11"e 13'11"e 13' 9'e 13' 9'8 12· 8'e 11' 3"1 11' 3'e 11' O'e 16' 11"e 16' 11'e 14' 7'e 14' 8'e 14' 8'e 13' 3'e 12· o·e 12· o·e 11' 7'e 17'9' 17' 3' 14'6' 15' 5' 15· 5• 13' 2' 12' 7"e 12' 7'1 11' 6'1 19· 3· 11· 11· 15• 2· 17' o·e 16' 4'8 13' 9' 13'11'e 13' 11'e 12' 0•1 20' 3· 18' 10· 15' 11' 17' re 17' 2'8 14· s· 14' 4"• 14' 4't 12' 7't 21' 2' 18' 5' 15' 7' 19' 2· 16'9' 14' 2' 16' g• 14'8' 12' 4' 22' 1' 19' 3' 16' 3' 20·0· 17'6' 14' 9' 17'6' 15' 3' 12' 11' 23' 2' 20' 3' 17' 1· 21' 1· 18'5' 15' 6' 18' 5' 16'1' 13' 7' 22' 8' 19'9' 16'8' 20'7" 18'0" 15' 2' 1s· o· 15'8' 13' 3' 23· 8" 20'8" 17' 5' 21' 6' 18'9" 15' 10 18' 9· 16' 5• 13· 10 r . .,., . .,., 41pef . .,., U240 L/3IO UIOO U240 L/3IO UIIOO U240 L/3IO UIOO U240 L/3IO UIOO 12'7' 11' 9' 9' 11· 11' 7• 11' 2' 9'5' 10' 10' 10' 8" 9'0' 9' 9• 9' 9' 8'4' 10' 10" 10' 8' 9'0' 10' 1· 10' 1' 8'6" 9•5• 9•5• 8' 2· 8'5'• 8' 5"e 7'r 8' 11· 8' 11' 7' 10' 8'3'e 8' 3'e 7' 8" 7'8"• 7'8'e 7' 2'• 8' 11'• 8' 11'• 8' 7"• 13'6' 12' 3' 10' 4" 12'6" 11· 8" 9' 10· 11'9" 11' 2· 9' 5' 10'8" 10'4" 8'9" 11' 9• 11'2' 9' 5• 10' 10· 10'7" 8' 11' 10' 2' 10' 2' 8' 7' 9' 1'e 9' 1·, 7' 11' 9' 7'a 9' 7'• 8' 3' 8' 10'• 8' 10'• 7' 10' 8' 3'e 8' 3'e 7' 8'e 7' s·e 7' 5'e 6' 11'e 14'6' 13'0' 10' 11' 13• s· 12'4' 10· 5• 12'7' 11' 9' 9' 11' 11' 3'e 10' 11' 9'3' 12'7' 11'9' 9' 11' 11'7' 11' 2· 9' s· 10'10'8 10'8'1 9'0' 9' 9'• 9' 9'• 8' 5'• 10' 3'e 10' 3"e 8' 8' 9'6"e 9' 6"e 8' 3'e 8' 10·• 8' 10'1 7' 11'1 7' 11'1 7' 11'1 7' 4'1 14' 5• 12' 7• 10' 7• 13• 9· 11· 11· 10· 1· 13' 1· 11'5' 9· 8' 12' 2' 10' 7' 8' 11' 13' 1· 11· 5• 9· 8" 12· 5• 10· 10· 9· 2· 11' 10' 10'4' 8' 9' 11'0' 9'8' 8'1" 11'5' 10· o· 8' 5' 10' 10· 9'6' 8' o· 10' 4' 9'1" 1· 8" 9' 3' 8'5' 7' 1' 15' 1' 13'2' 11'1' 14'4' 12'6' 10' 7• 13'8' 12'0' 10'1' 12' 9' 11' 1· 9'4' 13• 8' 12· o· 10' 1' 13'0' 11'4' 9' 7• 12· 5• 10· 10· 9· 2· 11'7' 10' 1' 8'6' 12· o· 10'5' 8' 10' 11'4' 9' 11' 8' 5' 10' 10' 9' 8" 8'0' 10'0' 8' 10' 7' 5' 15' 11' 13' 11' 11'9" 15' 1' 13' 3' 11' 2' 14' 6' 12· 8' 10' 8' 13' 5' 11' 9' 9' 11' 14· 5· 12'8" 10· 8" 13' 9• 12·0· 10' 1' 13' 2· 11'6" 9'8' 12' 2' 10' 8' 9'0' 12· 8' 11'0' 9' 4' 12'0' 10' 6' 8' 10' 11'6' 10'0' 8' 5• 10' 6" 9'4' 7' 10' 15• 5• 13' 5' 11'4' 14' 7' 12'9' 10'9' 14• o· 12' 2' 10'4' 13'0' 11' 4' 9'7" 14'0' 12' 2' 10' 4' 13' 3' 11' 7' 9'9' 12' 8' 11' 1' 9'4' 11' 9' 10' 4' 8'8' 12' 2' 10' 8' 9'0" 11'7' 10' 2' 8'7' 11' 1' 9'8" 8'2' 10' 4' 9'0' 7' 7' 16' 2' 14' 1' 11'11' 15' 4' 13' 5• 11'4' 14• 8' 12· 10· 10· 10 13• 1· 11· 11· 10· o· 14' 8' 12' 10' 10' 10 13' 11' 12' 2· 10' 3' 13' 4' 11' 8' 9' 10' 12' 4' 10' 10· 9' 1' 12' 10' 11'2' 9' 5• 12'2' 10' 8' 9'0' 11'8' 10'2' 8'7' 10' 10' 9· 5· 8'0' 17' 1' 14' 11' 12' 7• 16' 2' 14' 2' 11' 11' 15'6' 13' 6' 11· 5• 14· 5• 12' 7' 10' 7' 15' 6' 13'6' 11'5' 14' 9' 12' 10' 10' 10 14' 1' 12' 4' 10' 4• 13' 1· 11· 5• 9'8' 13• 8' 11· 10· 10· o· 12' 10' 11' 3' 9'6' 12' 4' 10'9' 9' 1' 11'5' 10· o· 8'5' 13'10'e 13'10'e 12' 3'! 12'10"e 12'10'e 11' 7'e 12· O'e 12· 0·1 11' 1·e 10' 9'e 10' 9"e 10' 4'e 12· o·e 12· o·e 11· 1·a 11' 1·e 11' 1"e 10' 6'e 10' 5'e 10' 5'e 10' 1'e 9' 3'e 9' 3'e 9' 3'e 9' 9'e 9' 9"e 9'8'e 9' 1·e 9' 1·e 9' 1'e 8' 6'e 8' 6'e 8' 6'e 7' 7'e 7' 7'e 7' 7'e 17' 1' 15'9' 13' 4' 1S10'e 15'0' 12' 8' 14'10"e 14' 4'e 12' 1• 13' 3'1 13' 3'e 11'3'1 14'10'e 14' 4'1 12' 1' 13' 8'e 13' 7'e 11' s·e 12'10"e 12'10"8 11' 0'• 11' 6'1 11' 6'e 10' 2·, 12' 1'e 12' 1·, 10' 7'e 11· 2·1 11· 2·e 10· o·, 10' 8'1 10' 6'e 9' 7'• 9' 4'e 9' 4'e 8' 11'1 19' 4• 16' 11' 14' 3' 13· s· 16' 1' 13' 7' 17' 7' 15'4' 13• o· 16' 4' 14' 3· 12'0' 17'7' 15'4' 13'0' 15· 8' 14' 7' 12'4' 16'0' 14· o· 11' 9' 14· 10· 13· o· 10· 11· 15'4" 13• 5· 11'4' 14' 7' 12'9' 10' 9• 14'0' 12' 2· 10' 3• 12'6"• 11'4' 9'7' 20'9' 18'2' 15'3' 19'9' 17' 3' 14'6' 18' 10' 16' 6' 13' 11 17'6' 15' 3' 12' 11 18' 10' 16' 6' 13' 11' 17' 11· 15' 8' 13' 2' 17' 2' 1s· o· 12' 7' 15' 11' 13' 11' 11' 9' 16' 6' 14• 5• 12'2' 15' 8' 13' 8' 11'6' 15'0' 13' 1' 11'0' 13' 11' 12' 2' 10' 3' 13' 6"e 13' 6'e 12T1 12· 6'e 12· 6'e 11'11'e 11· 8'e 11' 8"e 1r 5'e 10· 5"e 10· 5"e 10· 5"1 11' 8'e 11· 8"e 11· 5'e 10' 10"e 10' 10'8 10' 10"e 10' 1·e 10' 1•e 10' 1·1 9' l'e 9' 1'8 9' 1'8 9' 6'8 9' 6'e 9' 6'e 8' 10'e 8' 10'e 8' 10'e 8' 3'8 8' 3'e 8' 3'e 7' 5'e 7' 5'e 7' 5'8 14' 8'e 14' 6'e 13' 1•1 13' 5'e 13' 5'e 12' 5'1 12' 7'e 12' 7'e 11·11·1 11' 3'1 11'3"e 11' 0•1 12' 7'8 12' 7'111'11't 11· 8'8 11· s·e 11' 3'• 10'11'e 10'11'1 10'10'8 9' 9'e 9' 9'1 9' 9'1 10' 3'a 10' 3'e 10' 3'e 9• 6'1 9' 6'1 9• 6'• 8'11'e 8'11'18'11'1 7' 11'e 7' 11'e 7' 11·1 15' 6'e 15' S'e 13' 9'e 14' 4"e 14' 4'e 13' 1'8 13' 5'e 13' 5'8 12· 6'1 12· o·e 12' o·e 11' 1·1 13' 5'e 13' S'e 12' 6'1 12· 5'e 12' 5'e 11'10"e 11' 7'e 11' 7'e 11' 4'e 10' 4'e 10' 4'e 10' 4'1 10'11"e 10'11"e 10'11'e 10· 1'e 10' 1'e 10' 1'8 9' 6'e 9' 6'e 9' 6'8 8' 6'e 8' 6'e 8' 6"e 16' 2' 16'2' 13' 8' 15' o·e 15• o·, 13' o· 14' 0'e 14' 0'e 12' 5' 12' 7'e 12' 7'1 11' 6'1 14' 0'8 14' O'e 12· 5' 13' o·e 13' 0·1 11' 9'e 12' 2'e 12' 2'e 11' 3'e 10'10"e 10'10"1 10'6'1 11' 6'1 11' 6'e 10'10"8 10' 7'e 10' 7'e 10' 4'e 9' 11'e 9' 11·1 9' 10·1 8' 11'e 8' 11'e 8' 11'e 17' 11'e 16' 11· 14' 3• 16' 7'8 16' 1'e 13' 6' 15' 6'e 15' 4'e 12· 11· 13'11'8 13'11'8 12·0·1 15' 6'e 15' 4'e 12' 11· 14' 4'e 14' 4'e 12' 4'1 13' 5"e 13' 5'e 11' 9"e 12· o·e 12' o·e 1a11·e 12' 8'e 12' 8'e 11' 4'e 11' 9'e 11' 9'8 10' 9'e 11' o·e 11' o·e 10· 3'e 9' 10'8 9' 10'8 9' 6"• 18' s·e 17' 9"e 15' o· 17' 1·1 16'10"e 14' 3' 18' o·e 16' o·e 13'7'e 14' 4'e 14' 4'e 12' 7'1 1s· o·e 16' o·e 13'7'1 14' 10"e 14' 10"e 12' 11"e 13'10"e 13'10"e 12' 4'e 12· s·e 12· 5"e 11· 6'1 13' 1·. 13' 1·, 11·11·, 12' 1·1 12' 1'e 11' 3'1 11' 4"e 11' 4"e 10' 9'1 10' 2'• 10' 2'e 10' 0·1 19' 11' 17' 4' 14' 8' 18' 11' 16' 6' 13' 11' 18' 1' 15' 9' 13' 4• 16'9' 14· 8" 12'4' 18' 1' 15' 9' 13' 4• 17' 2' 15'0' 12' 8' 16'4' 14' 4• 12' 1' 14' 7' 13' 4' 11' 3• 15'4' 13'9' 11' 8' 14' 3· 13' 1· 11·1· 13' 4• 12'6" 10' 7' 11' 11' 11' 8' 9' 10' 20'9' 18' 1· 15' 3· 19'8' 17' 3' 14'6' 18' 10' 16' 6' 13' 11' 17'6" 15'3" 12'11 18' 10' 16' 6' 13' 11· 17' 11' 15' 8' 13'2' 17' 2' 15'0" 12'7' 15' 11' 13' 11' 11' 9• 18'6' 14'5" 12' 2' 15'8' 13'8' 11'6' 14' 8' 13' 1' 11'0" 13' 2'e 12' 2·1 10' 3' 21' 10· 19' 1· 16' 1· 20'9' 18' 1' 15' 3' 19'10' 17'4" 14' 7" 18' 5' 16' 1' 13'7' 19' 10' 17' 4' 14'7' 18' 10· 16' 5' 13' 10' 18' o· 15'9' 13' 3· 16'7" 14' 7' 12' 4' 17' 4• 15' 1' 12' 9' 16' 2' 14'4' 12' 1' 15' 1'e 13'9' 11' 7' 13' 6'1 12' 9'e 10' 9' 21'4' 18'7' 15'8' 20'3' 11· 3· 14· 11· 19' 4" 16' 11' 14' 3' 18' o· 15' 8' 13' 3' 19' 4' 18' 11' 14' 3' 18'5' 18' 1' 13' 7' 17' 7• 15' 4' 12' 11' 16'4' 14' 3' 12· o· 16' 11' 14' 9' 12' 5' 16'1' 14'0' 11'10' 15'4' 13' 5' 11'4' 13' 11' 12' 5' 10· a· 22' 3· 19' 5' 16'5' 21' 2' 16'5' 15'7' 20'2' 11· 8" 14• 11· 18'9' 16' 5' 13' 10' 20' 2· 17' 3· 14· 11· 19' 2· 16' 9' 14'2' 18' 4• 15· o· 13'6" 17' 1' 14' 11· 12' 7' 17'8" 15• s· 13'0" 16'9" 14· 3· 12'4" 16'0' 14'0" 11' 10' 14' 11· 13'0' 11·0· • • Qualls Engineering Structural Engineering Services FOUNDATION DESIGN Allowable Soils Bearing Capacity Building Height Proicct: State Street Engineer: 0Cc.G=------ \j(l(J 2 Use, ~--1-5-=i-n,_h_w-id_e_x ________ _ 18 inch deep footing with 2 # 5 top and bottom Allowable Max Line Load W ma~ = b X :\SHP 1,875 Allowable Max Point Load ]>max = b X 2d X .\SHP 5,625 Spread Footing Design P,n.,x = b~ X ASBP Square Spread Footing Schedule Footing ID Width (ft) Depth (ft) Pmu (lbs) Bar Size F2 2 2 6,000 (, F2.5 2.5 2 9,375 - F3 .1 2 13,500 (, F3.5 ).5 2 18,375 (, F4 -I 2 24,000 6 FS 5 2 37,500 (, F6 6 3 54,000 9 F7 -3 73,500 ') F8 8 3 96,000 9 F9 ') 3 121,500 ') psf stories plf lbs Bar Quantitiy IE.W."" BTMI 3 3 4 5 5 6 5 6 7 7 Sheet: __,3cc7c__ __ Job#: ...:1.;,9.:.14-'-1'---Date· _____ _ ""1n1mum 1mens1ons Width fin'I Denth fin) 15 18 1--~CS 1-: N '\/ Il~<~>N1'1. I-=-: N'I'/~ l". INC·. SPLCI \LIZI1'<J 11' LL\D -.\1ULD -,\SIJLSIOS \ V \ V \ V.FCS-EN VIR() '-.'.\IE '-.'T, \ l '>ERVICES.C<>.\! February 18, 2020 PJ Simas CZ Building Group 107 S Cedros Ave #220 Solana Beach, CA 92075 RE: Asbestos Testing 2742 State Street, Carlsbad, California 92008 Drywall/Joint Compound, Skim Coat/Stucco Dear Mr. Simas; ... ~.-· This report documents the laboratory analytical results of the Asbestos PLM sampling conducted by Bond Mccowan Jr, CSST, working under the direction of Bond L. Mccowan, Sr. CAC. The ten (10) samples of Drywall/Joint Compound and Skim Coat/Stucco were collected on February 13, 2020, and submitted to EMlab P&K in San Diego, California, for processing. A total of twenty-one (21) samples were analyzed, including all layers. The laboratory analytical results of the samples indicate !lQAsbestos Containing Materials (ACM) were detected. Should you have any questions after reviewing the conclusions and recommendations contained within this report, please do not hesitate to contact the undersigned at (619)921-3121. ECS Environmental, Inc. remains available to assist you in any way possible. Sincerely, ECS Environmental, Inc. _....p" __..-.?:?;,,,-·~ ., ~..::,_ C /~,.-..,...--. Bond L. Mccowan, Sr. California Certified Asbestos Consultant Attachments: Table 1 Laboratory Analytical Results Chain of Custody Inspectors Certification 4876 SANTA MONICA AVE. SUITE 172 ~ SAN DIEGO. CA 92107 (0) 1-800-SJi-6'364 (F) 480-719-4465 WWW.ECS-ENVIRONMENTALSERVICF.S.COM Area Tested Type of Material Sample Number(s) Interior Drywall/ Joint 1 Comoound Interior Drywall/Joint 2 Comoound Interior Drywall/Joint 3 Compound Interior Drywall/Joint 4 Compound Drywall/Joint Interior 5 Compound Exterior Skim Coat/Stucco 6 Exterior Skim Coat/Stucco 7 Exterior Skim Coat/Stucco 8 Exterior Skim Coat/Stucco 9 TABLE 1 Asbestos Results 2742 State Street Carlsbad, California 92008 Sample Quantity Locations Building 1 Building 2 Building 2 1100 SF Building 3 Building 3 Building 3 Building 3 Building 2 3800 SF Building 2 Sample Description Compound (White) Drywall (White) Compound (White) Drywall (White) Compound (Beige) Drywall (White) Compound (Beige) Drywall (White) Tape (Cream) Compound (White) Drywall (White) Skim Coat (Light Gray) Stucco (Gray) Skim Coat (Light Gray) Stucco (Grav) Skim Coat (Light Gray) Skim Coat (Light Gray) Stucco (Gray) ND= None Detected CH=Chrysotile CR=Crocidolit A=Amosite N/A=Not Analyzed A/P=Assume Positive ***Contractor shall follow all OSHA regulations with samples less <1% Condition PLM Percent Results Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% Good ND 0% 3 Area Tested Type of Material Sample Number(s) Exterior Skim Coat/Stucco 10 TABLE 1 Asbestos Results 2742 State Street Carlsbad, California 92008 Sample Quantity Locations Building I Sample Description Skim Coat (Light Gray) Stucco (Gray) ND= None Detected CH=Chrysotile CR=Crocidolit A=Amosite N/A=Not Analyzed NP=Assume Positive •••contractor shall follow all OSHA regulations with samples less <1% Condition PLM Percent Results Good ND 0% Good ND 0% 4 .. •:. f' -::: euro ins EMLab P&K Report for: Bond Mccowan ECS Environmental, Inc.: CA 4876 Santa Monica Ave #172 San Diego, CA 92107-2811 Regarding: Approved by: Project: 27 42 State St, Carlsbad, CA EML ID: 2357657 Approved Signatory Michelle Goduti Dates of Analysis: Asbestos PLM: 02-18-2020 Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS.S-1267) NVLAP Lab Code 500034-0 All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received. The results include an inherent uncertainty of measurement associated 'Mth estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results 'Mth >1% asbestos concentration can be provided when requested. Eurofins EMLab P&K ('the Company") shall have no liability to the client or the client's customer 'Mth respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own 'Mllful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability ....;th respect to the Test Results exceed the amount paid to the Company by the client therefor. EMLab P&K, LLC EMLab ID: 2357657, Page 1 of 4 ·---·-·-------------------- Eurofins EMLab P&K 8304 Clairemont Mesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.emlab.com Client: ECS Environmental, Inc.: CA C/O: Bond McCowan Re: 2742 State St, Carlsbad, CA ASBESTOS PLM REPORT Date of Sampling: 02-13-2020 Date of Receipt: 02-18-2020 Date of Report: 02-18-2020 Total Samples Submitted: Total Samples Analyzed: Total Samples with Layer Asbestos Content > 1 %: 10 10 0 Location: 01, Drywall/ Compound Lab ID-Version+: 11233698-l Sample Layers Asbestos Content White Compound ND White Drywall ND Comnnsite Non-Asbestos Content: 1% Glass Fibers Sample Composite Homo11eneitv: Moderate Location: 02, Drywall/ Compound Lab ID-Version+: ll 233699-l Sample Layers Asbestos Content White Compound ND WhiteDrvwall ND Comnnsite Non-Asbestos Content: I% Glass Fibers Samnle Composite Homoeeneitv: Moderate Location: 03, Drywall /Compound Lab ID-Version+: ll233700-l Sample Layers Asbestos Content Beige Comnnund ND White IJrvwall with Brown Paper· ND Composite Non-Asbestos Content: 7% Cellulose I% Glass Fibers Sample Comnn.ite Homoeeneitv: Moderate Location: 04, Drywall / Com pound Lab ID-Version+: 11233701-l Sample Lavers Asbestos Content Cream Taoe ND White Joint Compound ND White Drywall with Brown Paper ND Comnnsite Non-Asbestos Content: 15% Cellulose Samole Comooslte Homoeeneitv: Moderate The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government Eurolins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimwn detection and reporting limit is less than I% unless point counting is perfonned. Floor tile samples may contain large amounts of interl'erence material and it is recormnended that the sample be analyzed by gravimetric }X)int count analysis to lower the detection limit and to aid in asbestos identification :j: A "Version" indicated by -"x" after the Lab ID# with a value greater than l imhcates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2357657, Page 2 of 4 Eurofins EMLab P&K 8304 Clairemont Mesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.emlab.com Client: ECS Environmental, Inc.: CA C/O: Bond McCowan Re: 2742 State St, Carlsbad, CA Date of Sampling: 02-13-2020 Date of Receipt: 02-18-2020 Date of Report: 02-18-2020 ASBESTOS PLM REPORT Location· 05 Drywall /Compound ' Lab ID-Version+: 11233702-1 Sample Layers Asbestos Content Cream Taoe ND White Joint Compound ND White Drvwall with Brown Pimer ND I Comnosite Non-Asbestos Content: 15% Cellulose Sample Composite Homoaeneity: Moderate Location: 06, Skim Coat / Stucco Lab ID-Version+: 11233703-1 Sample Layers Asbestos Content Liclit Gray Skim Coat ND Gray Stucco ND ' Samnle Comnosite Homo2eneitv: Moderate Location· 07 Skim Coat/ Stucco ' LabID-Versiont: 11233704-1 Sample Layers Asbestos Content Light Gray Skim Coat ND Gray Stucco ND Sample Comnosite Homoieneity: Moderate Location· 08, Skim Coat I Stucco Lab ID-Version+: 11233705-1 Sample Layers Asbestos Content Liclit Grav Skim Coat ND Samnle Composite Homo2eneitv: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any "ll"ncy of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected When detected, the minimum detection and reporting limit is less than I% unless point counting is perfonned. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification t A "Version" indicated by -"x" after the Lab ID# with a value greater than l indicates a sample with amended data. The revisionnwnber is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2357657, Page 3 of 4 Eurofins EMLab P&K 8304 Clairemont Mesa Blvd, Suite 103, San Diego, CA 92111 (866) 888-6653 Fax (623) 780-7695 www.emlab.com Client: ECS Environmental, Inc.: CA C/O: Bond Mccowan Re: 2742 State St, Carlsbad, CA ASBESTOS PLM REPORT Location· 09 Skim Coat I Stucco ' Sample Layers Limt Grav Skim Coat Gray Stucco Sample Composite Homoeeneity: Location: 10, Skim Coat / Stucco Sample Layers Limt Gray Skim Coat Gray Stucco Samnle Comnosite Homoi,eneitv: Date of Sampling: 02-13-2020 Date of Receipt: 02-18-2020 Date of Report: 02-18-2020 LabID-Versiont: 11233706-l Asbestos Content ND ND Moderate Lab ID-Version+: 11233707-1 Asbestos Content ND ND Moderate The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal govenunent. Eurofins EMLab P&K reserves the right to chspose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1 % unless point counting is performed. Floor tile samples may contain large arnomtts of interference material and it is reconnnended that the sample be analyzed by gravimetric JX)int count analysis to lower the detection limit and to aid in asbestos identification. t A ffVersion" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision mnnber is reflected by the value of "x", EMLab P&K, LLC EMLab ID: 2357657, Page 4 of 4 CHAIN OF CUSTODY l} EM Lab P&K ..... Fog Rail Snow WM a. . . REQUESTEDIEIMCES ·~. " www.EMLabPK.com ~· ATestAmenca Company None D D D D / CU..dec:kbo ... bllow) ] Lillhl I I ] r Ncrl-Oanbie CIAKlbit Cherry HI, NJ: 1936 Olney A~ Ctuwry HI, MJ 08003' 1•1111-1914 ~ Modelall 11 "J [] $pole Tape l!ioCassele"' Andel-.i. SAS SWab Oller Requests Phoenix.AZ: 1501 Westl<rullendrM!, Phoen~AZ85027'(IOO) &5UI02 IHeaYv "" 0 7 rl Trap Swab w•. M.~ Sol-~ San Bruno, CA: 1150 Bayhl DIM, 1100, San 8runo, CA~• (II&) MM653 l----.....-l-:Bulk=....-1-,......,.-.--~r--r---r--r-,---lt-,--,---,.-, CONTACT IWORMATION ' -I C011'4)111y: EC$ A.dlr• -i S ~ Conlact. l3ond Special lnstnldions: --=---:---:-.; i I tl §!1--:-j ~ 8~ Phone: '600 5\1 l:i3to7 t t t ~.., i ,:... I J PROJECTIWORIIATION TURNAROUNOTIIIECODES(TAT) t I I Q Q Q t t I i .:.<. I I ProjedlO: :nl¾, S+<Ak cs+, LQnsbO-.d, o\-sro-Staud(OEFAULT) Rulhlll9CMl*2""' I.~ ! I i J i i ) l ~ -J J ! i ~-. -ND-Next8UWS&Day ::=-...:: J 1 ! ] Ji}~ -'§ 11 I~ ~ ,.,_ ~ ~ q~ 1 =--~1,~,"° •0 ---... .,.. =.::..z i 1 p I H I h 1 1 1 . H t :z = --~,.. ;;w..::~;;-___ ;.,.., ii I h H u h h i II ~ I o( Or141.\}o,.\\ / C'OfV\polµ\d r1i NIA N A □ □ 0 D D D O D O □ D □ □ 0 □ ~ □ □ ~ 000000000000 □□□0 □□ ~ □□□□□□o □oo □o □□□~□□ ~ 000000000 □□□□□□~□□ ~ 0000000000 □□□□□~□□ ov Skim coo..t / S+tACc.o O O O O O O O O O O O □DO D IZI □ □ n 0000000000000 □□~□□ ~ 000000000000000~0 □ ~ 000000000000000~□□ 10 000000000000000~0 □ 1., ___ ___. ____________ ...___--'--------------□0000 □000000000000 IMIU TVP£COOH Ra.llQIIIIHEO IV DATUTIE 8BYEDIV DATUTIE BC-BloC•Nlle,. ST -5pol'e Trap. Zefon. T-Tape D-IMI I~ () J? ~ A 1S -Anderson Alelgenco, 8unanl ... SW-SWab SO-Soi SAS-Surface~~ P-PollbleWlltll B-U -~ v- CP-Conlad PIiie NP-Non-PolltileW8"" 0-0hr: By submllilg .. Chain of CullOdy, )'Ill 11P' to be bOllld by lie lerms and cmlMons sec bth at ht1D /6r,yw.e;nllb,C0(11§1maiot'HF)ioetemls him! ~l02.002•2012EKabP&K Ooc.'11UllefJl ....... 12hl1 ..... 1ef\O,. PROPERTY FIELD SKETCH Address: ;r74 d-~t-oJ-.e, '5\--1 w\ Sb4.d, c 4 qx,c,<c Drawn by: t!)bV\_d \\,\ C(owo.n Page I of Date:_ ,-.... -, .... ·,·. ., .. --, .. ' ' . "'"\"' -r ..,.,. '\' • ' ' ' , • • ·•· • • .. , • • • , • • ..... , .. -.. , • r • • , ·, • r f •" • , --.. 1 - ' ' ' ' . . . . . N o , I I • I I t :----~----}--:·-·-~•"'••}-·-... ~----:•--··! ... -·-} --~ .. -· .. {-···~ -·· :·-•"'1·----t--·-~ .. -... ~--.. -~.-·-~---~·-· .. :~ ---: _, ____ , ................ •-··-'·-··"· : t t I J : I t t I • t t I O • I I ' , I I I I I I I I I I • I ............. ._ ---~ ................. ••'-••· ..... ·-·----·--........................................ ~--_, . ' I I t j t I I ' ·-., __ .. I I I I f • I I ..... -.:..--t: ..... ---1--~-,,t,,----+~-.i..,.-,,~,--;-,-~,:---:::-=-::";.-:----;\ --~----~---·~---~----~----~----~---~---~~--·-~--·~----!----: -.t... ...... 1 ' ' :-: -.. : . . . ' . ' . --~·---~-·--~----:----~···~ --·~· J o I I . ' ' I • .. __. !• • • • . -:--•-{----~-.. -•:----,---: ........ :•----:---·1····: .... -·-: ---:•--: ' ' ' . ' ' ' . . . ' . ' . ..... i. ............ ~ . . ' -:'fll••·~---~-.. --~--.. -~-~·~·---~····: .. ··!·---~---·:····~ I I I I : .. -... ! ... --. ' . t ..... __ ,. ........ ---♦-... -►• ·-.... .... • • .. .. .... "' ... I I I I • I I -,. .......... ~ ............................ : .... -................ ;-·-.. .. ' ... , ..... ' ' t· --,- o I • • • t I I I I I • I I l I ··~,. .. .. " ·-r ·"'·••·1"···r·-••-"'-•1 I I I f . . ' ' . . ' ' -!•--••~••••:•• : • !• I : .. •: :••-•~•• "\•• t- i , t t I t I f t • I :---·{---·:.. ·:•··•{--··: .½r?!-~o~{-j,,. .. ·:·-·-~·--· .. :··· .. ~· ~ .. -:·-••1--·--~----·:·-·-{• ...... f--··:··--~·-•-{-*••·:----~····~- t f I I t I I I t 1 t l I I I I l I t O 1 I 1 I I o , I • • o t I I , .... ~.---~ ........... J,. ___ .. ~.,. -.... -.. -...... -• J -... -• -... • I,. ............... ., -.......... -........................ -.. --~ .. --., .... -....... -........ ~ ..... ., ' .. -... . I 1 I • • t I t ' t I I I I , t I I I t f l I I I ,. ' ' ·, -... , ..... -.. - ' :-..... ) > --.. ' • ., I• • W: ... -. ' -' . ' :----!-- , .. ' , .. I t I I I I I 1 t t j !-............ ----! ..... ., t • I I • f • I I I i I t I I I I , .... -... -,. ...... ---..... --.. 1 • .... ... .. -........ ",. ..... ., .... -.. ----,. • ---~ ... -"'"' --• ~ -....... -.. ~-......... t • I • • ' I I I o o I ' ' •• •• I • . . --,--. . . ( •·t'"--.. •:---·:. ,. : -.. , ....... i --: ...... : ........ ; ....... : ..... ,_; .... : •.• . ' . ' . ' ' . ' ' ' ' ' --:--.. ~----~·· .. -:-·· ·~----! .. ,. .. -!-• --'!· .. ··! .... --:,-.. ··~· ...... ! .. I I I I f I f t ··-··"----'-..... , .... ,..J .............. ·----:----~--··: -~·--·:··--{··--:· I I I I I I --► --•-►------►-----······---.. ---...... .. -·-- ' ' . .. r --• ·r • • • 1 •·: ·---:•---:-.. . . . ' ' ~~~3~-- ' ' ~ . . ' ....... . ' . ,. 1•-~---! ----~-----·· .... ·····~----,---•---· ~--◄---··-·-••· -' . . I t I t ! . '1/. :o ' ................. ' -.. --..... -... ' . f I o I o .,.I ., ... {"'" ...... ~•-• •:• .... _ ·: ... •• t· • . ' ··-r:-~wtf,~ 1.; .. ,-.. ,. ...... 1 I t I ' ' .. ..-,. ' ' I I I I :·---~----~-· ' ' ·ot : --~·--.. :··-.. :-···: ' ' . ' ·-----◄•-...... lo ~-·-·:····~ -,. ' ' ' . ' ' . . ................ _•"'"1•-----... -............. ·-.. -.. . . . . ' , .. ' . 'I" •• I .... { ......... i ........... : . . . ' . .. -...... -.. ·--.. , ' ' ' , ...... :E ; ..... ~--... ~ ......... ~ ' ' . ................. , . ' ' ' ' ..... ---... --... -.. .. \- ··-~---~---·!· ' ' I f I • t t o t I I f I , • f o f I o I • ,-.. -, " :-•••:·•..,•~••••: ••..,:·•• ~• .. t ••••~-• ~--.. : • :•-.. ·i• ... .,... ,•• r-~-~•• •r••-~•••-~ r •••°'••••T••••1 I I I • I I I I f f I f I I • f I t • t t t t I I I 1 :--·-:--··}-----:----·~---}·-.. ·!·----{-·-·:·-··;'" ........ ;.-•-¼·---:--.. -:-...... : ....... ~·---:----·:--·-~· -·: ... i·--}··-~---·~----;""··· .----:----•: t I I t I t I o I o I o t I • I I I I • I t I t I 1 I • I I o • t I t I I t t • I f I ; .. ~ .. ··~ --~----:--· -~---:----~;----~---·-:··-·~---~----~ .. --·~···~-· .... ! .... ~----'-·-·-:-·-·-~-.. -.......... ~----~--··:-···~-----~ ... -.: I I I 1 I I I I I I t I t t•• -~-•••: .. ••.:..•••~•--•--:••• .... ..,.,. .. !,..,.... I ► ••••• ~ ..... ._..:, ... : ...... -,-........ ~_,..,,.,.:•• ~-•• ,-....... .,, ..... ..:,. "'•:• • ~••-~--• I I t f I I I • I :•••-~•-• :---: ...... ·!• • ~--·: .. 'l•--} ........ ;~ .... "\ ••;•-• • r {-••f •••!---•,{ .... ! • •"\• "'f ..... ;. .... i. t • I o • I :····!··--~----:·--·~--· .... ~ -··: ·--~ .. ·--·t· ··!--· ~--! ·!" ...... 1 ...... -". -·~ -~ ~ I • I : : s : --.. ~ ...... :· .. Loca . n/S . e/U . K tJO Ult mt ey: 1. EXTERIOR 8. 15. 2. 9. 16. 3. 10. 17. 4. 11. 18. 5. 12. 19. 6. 13. 20. 7. 14. 21. . .. ' . ' t -·••' ' . • Hazardous Materials Questionnaire County of San Diego, Department of Environmental Health PO Box 129261, San Diego, CA 92112-9261 (858) 505-6700 (800} 253-9933 www.sdcdeh.org Business Name State Street Commons, LLC Project Address 27 42 State St Applicant Brendan Foote Business Contact Brendan Foote City Carlsbad State CA Applicant E-Mail C\ brendan@fabricinvestments.co one# The following questions represent the facility's activities, NO the specific project description. Plan File# APN# 203-181-19-00 PART I: EIRE DEPARTMENT -HAZARDOUS METERIALS DIVISION: OCCUPANCY CLASSIEICATION:(Not required for projects within the City of San Diego.) Indicate by selecting the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are selected, Applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: D Explosive or Blasting Agents D Compressed Gases D Flammable/Combustible Liquids D Flammable Solids D Organic Peroxides D Oxidizers D Pyrophorics· D Unstable Reactives Facility's Square Footage (including proposed project): D Water Reactives D Corrosives D Cryogenics D Other Health Hazards D Highly Toxic or Toxic Materials D None of These D Radioactives PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION (HMDut the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, in person at 5500 Overland Ave., Suite 110, San Diego, CA 92123, or by phone at(858) 505-6700 prior to issuance of a building permit. FEES ARE REQUIRED. Project Completion Date: 12/3112020 1. 2. 3. 4. 5. 6. 7. 8. YES NO D l!l D l!l D Ii!! D Ii!! D 1B D Ii!! D Ii!! D Is your business listed on the reverse side of this form? (check all that apply). Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, or 200 cubic feet? Will your business handle carcinogens or reproductive toxins in any quantity? Will your business use an existing, or install an underground storage tank? Will your business store or handle Regulated Substances (CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). D D D CalARP Exempt CalARP Required CalARP Complete Review Date: PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): If the answer to Question #1 is 'Yes' and the answer to Question #2 is 'No', the applicant must contact the APCD prior to the issuance of a building or demolition permit. If any answer to Questions #3, #4, or #5 is 'Yes', the applicant must contact the APCD prior to the issuance of a building or demolition permit. If the answer to Question #3 or #4 is 'Yes', the applicant may need to submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation (some residential projects may be exempt from the notification requirements). Contact the APCD at 10124 Old Grove Road, San Diego, CA 92131 or telephone (858) 586-2600 for more information. YES NO l!l D l!l D D Ii!! Will any existing building materials be disturbed as part of this project? (If the answer is 'Yes', an asbestos survey may be required.) Has a survey been performed to determine the presence of asbestos containing materials? Will the project involve handling or disturbance of any asbestos containing materials? 1. 2. 3. 4. 5. D Ii!! D l!l Will the project involve the removal of any load supporting structural member? Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdapcd.org/info/facts/permits.pdf (ANSWER ONLY IF QUESTION 5 IS 'YES') Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? Search the California School Directory at http://www.cde.ca.govlrelsdl for public and private schools or contact the appropriate school district. 6. D Briefly describe business activities: Briefly describe proposed project: Commercial renovation of existing buildings. Project will house 2 restaurants, 1 Adaptive Reuse and renovation of three existing buildings of approx. 20,000 sf. cafe and 1 office tenant. I declare under penalty of perjury that to the best of my knowledge and belief, the responses made herein are true and correct. Ii!!; Fees Acknowledged: l!l Brendan Foote 2/19/2020 Name of Owner or Authorized Agent Date FOR OFFICIAL USE ONLY FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: BY: DATE: ___________ _ EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMO• APCD COUNTY-HMO APCD COUNTY-HMO APCD 2/19/2020 • <:'lo ~o 1'.,,i,,_ 0~ 'YOF 'SI'-~ • A stamp in this box l2lll¥ exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. DEH_HMD_Plan_Check_Queslionnaire v1 .2 (1012015) Printed on: 2/19/2020@ 2:56 PM ( City of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) T ❖ Pool "' If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. "' Details on CAP ordinance requirements are available on the city's website. "' A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. Application Information Project Name/Building Permit No.: s+'1tc .,S' fvet+ [ow,»" W\ S BP No.: Property Address/APN: Z.o3 -IS?l -/'1 -DO Applicant Name/Co.: Applicant Address: Contact Phone: Contact Email: Contact information of person completing this checklist (if different than above): Name: Company name/address: Contact Phone: Contact Email: Applicant Signature: ___ (!J_.._J--+---=eg_c.-_~-----Date:_..;_/ D__.__/_1-1./_,_/ j..,__ __ B-50 Page 1 of 6 Revised 08/19 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet: $ ______ _ \ / Construction Type D Residential □ New construction □ Additions and alterations: □ BPV < $60,000 □ BPV <!: $60,000 □ Electrical service panel upgrade only □ BPV <!: $200,000 / ~onresidential ~ New construction ., □ Alterations: □ BPV <!: $200,000 or additions<!: 1,000 square feet □ BPV <!: $1 ,000,000 □ <!: 2,000 sq. ft. new roof addition Checklist Item I Complete Section(s) I Notes: A high-rise residential building is 4 or more stories, including a Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use 2A, 3A, 1B, 28, 4A 3B,4A NIA NIA All residential additions and alterations 1A, 4A 4A 1-2 family dwellings and townhouses with attached garages only *Multi-family dwellings only where interior finishes are removed 1A, 4A* 1B, 4A* and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed 1 B, 2B, 3B, 4B and 5 1B,5 1B, 2B, 5 Building alterations of<!: 75% existing gross floor area 28,5 1 B also applies if BPV <!: $200,000 Check the appropriate boxes, explain all not applicable and exception ttems, and provide supporting calculations and documentation as necessa,y. 1. Energy Efficiency Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CAL Green) for more information when completing this section. A D Residential addition or alteration 2: $60,000 building pennit valuation. □ NIA _________ _ See CMC section 18.30.190. D Exception: Home energy score ~ 7 (attach certification) Year Built Single-family Requirements Multi-family Requirements D Before 1978 Select one: D Duct sealinQ D Attic insulation D Cool roof D Attic insulation D 1978 and later Select one: D Lighting package D Water heating Package D Between 1978 and 1991 Select one: D Duct sealina D Attic insulation D Cool roof D 1992 and later Select one: D Lighting package D Water heating package B. ~ Nonresidential* new construction or alterations 2: $200,000 building pennit valuation, or additions 2: 1,000 square feet □ NIA Updated 8/15/2019 2 City of Carlsbad Climate Action Plan Consistency Checklist See CMC 18.21.155 and CALGreen Appendix AS, Division AS.2 -Energy Efficiency. A5.203.1.1 Choose one: ™ Outdoor lighting D .2 Warehouse dock seal doors D .3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended) D N/A _________ _ Daylight design PAFs D .5 Exhaust air heat recovery AS.203.1.2.1 Choose one as applicable: '$..95 Energy budget D .90 Energy budget D N/A A5.211 .1** ~On-site renewable energy D N/A AS.211 .3 .. D Green power (if offered by local utility provider, 50% minimum renewable sources) D N/A '( AS.212.1 D Elevators and escalators D NIA ~ AS.213.1 • D Steel framing D NIA • lndudes hotels/motels and high-rise residential buildings .. For alterations;:: $1,000,000 BPV and affecting> 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with CMC 18.30.130 instead. 2. Photovoltaic Systems ~ A. D Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1 (c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (28 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(8) (high-rise residential) or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #d.u. Calculated kWdc* sheets if necessary) Total System Size: kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.) *Formula calculation where CFA = conditional floor area, #du = number of dwellings per plan type If proposed system size is less than calculated size, please explain. Exception D D D D kWdc 8. ~ Nonresidential new construction or alterations 2!:$1,000,000 8PV and affecting 2!:75% existing floor area, or addition that increases roof ~ area by c!:2,000 square f~l Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and'hotel/motel buildings. Choose one of the following methods: J Gross Floor Area (GFA) MethAd GFA: ,q,o'3 '6 Min. System Size: ~kWdc D If< 10,000s.f. Enter: 5 kWdc Xif <!: 10,000s.f. calculate: 15 kWdc x (GFA/10,000) ** **Round building size factor to nearest tenth, and round system size to nearest whole number. D Time-Dependent Valuation Method Updated 8/15/20 19 3 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:••• _____ _ x .80= Min. system size: ____ _ kWdc ***Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A D Residential and hotel/motel new construction Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. □ For systems serving individual dwelling units choose one: □ Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) □ Heat pump water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1 (c) 14 (low-rise residential) □ Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher □ Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors □ Exception: □ For systems serving multiple dwelling units, install a central water-heating system with all of the following: □ Gas or propane water heating system □ Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low- rise residential) □ Solar water heating system that is either: □ .20 solar savings fraction □ .15 solar savings fraction, plus drain water heat recovery xception: Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. □ Water heating system derives at least 40% of its energy from one of the following (attach documentation): □ Solar-thermal □ Photovoltaics □ Recovered energy □ Water heating system is (choose one): □ Heat pump water heater □ Electric resistance water heater(s) □Solar water heating ystem with .40 solar savings fractio '83: Exception: · l i Updated 8/15/20 I 9 4 City of Carlsbad Climate Action Plan Consistency Checklist • 4. Electric Vehicle Charging A. D Residential New construction and major alterations* Please refer to Carlsbad Ordinance CMC section 18.21.140 when completing this section. □ One and two-family residential dwelling or townhouse with attached garage: □ One EVSE Ready parking space required □ Exception : □ Multi-family residential· □ Exception · Total Parking Spaces EVSE Soaces Proposed Caoable I Readv I Calculations: Total EVSE spaces = .10 x Total parking (rounded up to nearest whole number) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces-EVSE Installed (EVSE other may be ·capable," "Ready" or "Installed.") Installed I Total I *Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building perm~ valuation~ $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation ~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. B 1B) Nonresidential new construction (includes hotels/motels) □ Exception · Total Parking Spaces EVSE Soaces Proposed Capable I Readv I Installed I Total '+ I I I Calculation-Refer to the table below· Total Number of ParkinQ Soaces provided Number of reauired EV Soaces Number of reauired EVSE Installed Spaces D 0-9 1 1 D 10-25 2 1 a 26-50 4 2 D 51-75 6 3 D 76-100 9 5 D 101-150 12 6 D 151-200 17 9 D 201 and over 10 oercent of total 50 oercent of Reouired EV Soaces Updated 8/ I 5/2019 5 City of Carlsbad Climate Action Plan Consistency Checklist . . # 5. 'f& Transportation Demand Management (TOM): Nonresidential ONLY An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TOM plan. If TOM is applicable to your permit, staff will contact the applicant to develop a site-specific TOM plan based on the permit details. Acknowledgment: Employee ADT Estimation for Various Commercial Uses Emp ADTfor first 1,000 s.f. EmpADTI 1000 s.f.1 Office (all)2 20 Restaurant 11 Retail3 8 Industrial 4 Manufacturing 4 Warehousin 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 1()lhEdition 13 11 4.5 3.5 3 1 2 For all office uses, use SANDAG rate of 20 ADT/1,000 sf to calculate employee ADT 3 Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf / 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. 8,334 sf/ 1,000 x 4.5 + 8 = 46 Em lo ee ADT I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should my pennit require a TDM ~?"' und"'1a,,j' lha~approved TDM plan O a condmon of pennit issuance. Ap~icanl SignalUre: -fJ J' c_;,.,-,e:__. Date: I O / I / I 'J Person other than Applicant to be contacted for TDM compliance (if applicable): Name (Printed): 6 ':) { C> f e.ri-,,a "1 Phone Number: 'ii' O) -7 l/1,, --/,,S/ lo Email Address: J re j @3L O I e,W\ "'1,-, a ce:h . l&2 W\ Updated 8/15/2019 6 PERMIT REPORT Revision Permit Print Date: 09/08/2021 Job Address: 2742 STATE ST, # A, CARLSBAD, CA 92008-1628 {city of Carlsbad Permit No: PREV2020-0087 Status: Closed -Finaled Permit Type: BLDG-Permit Revision Work Class: Residential Permit Revisii Parcel#: Valuation: 2031811900 $0.00 Track#: Applied: 06/13/2020 Lot#: Issued: 07/07/2020 Occupancy Group: #of Dwelling Units: Project#: DEV2019-0048 Finaled Close Out: 07/14/2021 Bedrooms: Bathrooms: Project Title: STATE STREET COMMONS Plan#: Construction Type: Orig. Plan Check#: PC2019-0066 Plan Check#: Inspector: Final Inspection: Description: STATE STREET COMMONS: ROOF TOP MECHANICAL REMOVED (WILL BE PART OF Tl INSTEAD)// NEW GAS LINE ADDED IN BU FEE BUILDING PLAN CHECK REVISION ADMIN FEE MANUAL BLDG PLAN CHECK FEE Property Owner: STATE STREET COMMONS, LLC 2659 STATE ST, # 100 CARLSBAD, CA 92008-1627 (619) 840-7721 Total Fees: $147.50 Total Payments To Date: $147.50 Building Division CoApplicant: C2 BUILDING GROUP 107 S CED ROS AVE, # STE 220 SOLANA BEACH, CA 92075-1994 (858) 232-0213 Balance Due: AMOUNT $35.00 $112.50 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov C City of Carlsbad PLAN CHECK REVISION OR DEFERRED SUBMITTAL APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Original Plan Check Number PC2019-0066 Project Address 27 42-2752 State Street Plan Revision Number G S f R . . f S . Removal of rooftop mechanical from the shell submittal to be eneral cope o ev1s1on/De erred ubmrttal: ___________________ _ submitted as part of the tenants Tl submittal and the addition of a gas line to fireplace that was previously shown on the plans CONTACT INFORMATION: Name Greg Coleman Phone 805-7 46-6516 _________ Fax'------------ Address 3594 Herman Ave City San Diego Zip 92104 Email Address greg@gcolemanarch.com Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: Ii] Plans D Calculations D Soils D Energy D Other 2. Describe revisions in detail The roof top mechanical units on Bldgs B and C have been removed and will become part of the tenant Tl A new gas line was added in Bldg A to go to the fireplace shown on the west wall of the building 4. Does this revision, in any way, alter the exterior of the project? D Yes 5. Does this revision add ANY new floor area(s)? D Yes 6. Does this revision affect any fire related issues? D Yes 7. Yes Iii No 0 No Ii] No 3. List page(sJ where each revision is shown M0.2,M0.5, M0.6,MO. 7 ,M2.1,M2.2,M2 .3 P2.1, P5.2 Ii] No Date 6/8/2020 1635 Faraday Avenue. r/sbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov Carlsbad PC2019-0066.Rev3 (PREV2020-0087) 6-17-20 DATE: 6-17-20 JURISDICTION: Carlsbad ✓• EsG1I A SP1F~_built Cornn.-:t('y ~\ ( ,. c/4,PLICANT / JURIS. PLAN CHECK#.: PC2019-0066.Rev3 (PREV2020-0087) ___ SET: I PROJECT ADDRESS: 2742-2752 State Street PROJECT NAME: State Street Commons (plan revision, remove rooftop mechanical units on Buildings B & C and add one gas line to Building A for fire place) C8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: C8J EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. □ Person contacted: Telephone#: Date contacted: l,{f1}2D (b¥fY}) Email: Mail Telephone Fax REMARKS: By: Scott Humphrey EsGil In Person 6-16-20 .·Ji~ V (. · \_ ()JV :r: ) CJ Enclosures: Carlsbad PC2019-0066.Rev3 (PREV2020-0087) 6-17-20 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad (PREV2020-0087) PLAN CHECK#.: PC2019-0066.Rev3 PREPARED BY: Scott Humphrey DATE: 6-17-20 BUILDING ADDRESS: 2742-2752 State Street BUILDING OCCUPANCY: BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance ,--------~,· ~ I Bldg. Permit Fee by Ordinance ! ,.. I Plan Check Fee by Ordinance ,.. ' Type of Review: r Complete Review r Structural Only I Repetitive Fee ! ,.. : Repeats : r , , 1 Other r,, Hourly EsGil Fee , c=:=::]Hr.@* ~ * Based on hourly rate ($) $90.ooJ Sheet 1 of 1 PERMIT REPORT Revision Permit Print Date: 09/08/2021 Job Address: (city of Carlsbad Permit No: PREV2020-0053 Status: Closed -Finaled Permit Type: 2742 STATE ST, # A, BLDG-Permit Revision 2031811900 CARLSBAD, CA 92008-1628 Work Class: Residential Permit Revisi1 Parcel#: Track#: Applied: 04/07/2020 Valuation: $0.00 Lot#: Issued: 06/11/2020 Occupancy Group: #of Dwelling Units: Project#: DEV2019-0048 Fina led Close Out: 07/14/2021 Bedrooms: Bathrooms: Project Title: STATE STREET COMMONS Plan#: Construction Type: Orig. Plan Check#: PC2019-0066 Plan Check#: Inspector: Final Inspection: Description: STATE STREET COMMONS: CHANGE IN ORIENTATIN OF ONE STAIR & THE REDESIGN OF SOME STRUCTURAL ELEMENTS FEE BUILDING PLAN CHECK REVISION ADMIN FEE MANUAL BLDG PLAN CHECK FEE Property Owner: STATE STREET COMMONS, LLC 2659 STATE ST, # 100 CARLSBAD, CA 92008-1627 (619) 840-7721 Total Fees: $560.00 Total Payments To Date: $560.00 Building Division CoApplicant: C2 BUILDING GROUP 107 S CEDROS AVE, # STE 220 SOLANA BEACH, CA 92075-1994 (858) 232-0213 Balance Due: AMOUNT $35.00 $525.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov { Cicyof Carlsbad PLAN CHECK REVISION OR DEFERRED SUBMITTAL APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Original Plan Check Number PC2019-0066 Project Address 2742-2752 State Street Plan Revision Number G IS f R . . ,10 f d S . Change in orientation of one stair and the addition/redesign enera cope o ev1S1on1 e erre ubm1ttal: ___________________ _ of some structural elements CONTACT INFORMATION: Name Greg Coleman Phone 805-7 46-6516 _________ Fax'----------- Address 3594 Herman Ave City San Diego Zip 92104 Email Address greg@gcolemanarch.com Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: Ii] Plans Ii] Calculations D Soils D Energy D Other 2. Describe revisions in detail Structural frame spanning between grid lines 1 & 4 and F & G was change to a moment frame Openings in the north side of the quonset hut were reduced from 2 to 3. Door configurations were adjusted A structural frame was added to the electrical room to aid in pulling the electrical service line The exit point out of the back of Building C was reconfigured at grid lines H & 10 The interior stair at Building C was rotated 90 degrees Steel trellis beams and one post were added to the exterior patio on the west side of Building C The storage closet at grid lines 11 & E was removed The door to the elevator machine room at grid lines H & 11 was moved from interior to exterior 4. Does this revision, in any way, alter the exterior of the project? Ii] Yes 5. Does this revision add ANY new floor area(s)? D Yes 6. Does this revision affect any fire related issues? Ii] Yes 7. Yes D No Ii] No 0 No 3. List page(s) where each revision is shown A 1.2 / A2.0 / S2.0 / S3.0 A 1.2 / A2.0 / S2.0 / S3.0 A1 .2 / A2.0 / S2.0 / S3.0 A 1.2 / A2.0 / S2.0 / S3.0 A 1.2 / A2.0 / S2.0 / S3.0 A1 .2 / A2.0 / A2.2 / S2.0 / S3.0 A1 .2 / A2.0 A1 .2 / A2.0 0 No Date 4/6/2020 1635 Faraday Avenue. Ph: 760-602-2719 Fax: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov DATE: 4-17-2020 JURISDICTION: Carlsbad ✓• EsG1I □ APPLICANT □ JURIS. PLAN CHECK#.: PC2019-0066.Revl (PREV2020-0053) __ SET: I PROJECT ADDRESS: 2742-2752 State Street PROJECT NAME: State Street Commons-Structural Changes D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Greg Coleman Telephone#: 805-746-6516 Date contacted: (by: ) Email: greg@gcolemanarch.com Mail Telephone Fax In Person 0 REMARKS: By: Erich A. Kuchar, P.E. Enclosures: EsGil 4-9-2020 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad PC2019-0066.Revl (PREV2020-0053) 4-17-2020 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK#.: PC2019-0066.Revl (PREV2020-0053) JURISDICTION: Carlsbad OCCUPANCY: B/ A2 TYPE OF CONSTRUCTION: V-B ALLOWABLE FLOOR AREA: SPRINKLERS?: Yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 4-6-2020 DATE INITIAL PLAN REVIEW COMPLETED: 4-17-2020 FOREWORD (PLEASE READ): USE: Buisness ACTUAL AREA: 11,092 sft 1st Floor 7,946 sft 2°d Floor 5,200 sf! Patio STORIES: 1 and 2 stories (Varies) HEIGHT: Varies OCCUPANT LOAD: DATE PLANS RECEIVED BY ESGIL CORPORATION: 4-9-2020 PLAN REVIEWER: Erich A. Kuchar, P.E. This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Unifonn Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad PC2019-0066.Revl (PREV2020-0053) 4-17-2020 GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. STRUCTURAL 2. Provide complete calculations and detailing for the foundation of the new Intermediate Moment Frame. The connection of the Steel Frame to th e Column Base shall be designed to transmit forces to the foundation per CBC. Column base elements include anchor bolts, base plate welds and any elements that transfer shear, moment, or tension to the foundation: AISC 341-D1-4a(2). Please see the next item as well for the required load combinations: a) The seismic loads to be transferred to the foundation interface shall be based upon the seismic load combinations of ASCE 7-10, Section 12.4.3.2. b) Design of concrete elements at the Column Base, including anchor rod embedment and reinforcement steel, shall be in accordance with CBC, Chapter 19. c) Grade beams shall be provided with ductile detailing per ACI 318, Sections 18.7 & 18.13. 3. Seismic Load Effect j.i•Xi=6iW a) Seismic load effect, E. The seismic load effect, E, should be computed in accordance with the following equation set forth in ASCE7-10, Section 12.4.2: E =pQE + 0.2SosD b) Maximum seismic load effect, Em. The maximum seismic load effect, Em, should be computed in accordance with the following equation set forth in ASCE7-10, Section 12.4.3 to be used in the special seismic load combinations of Section 12.4.3.2 Em= OoOE + 0.2SosD INTERMEDIATE MOMENT-RESISTING FRAME REQUIREMENTS 4. The pre-qualified moment connections shall comply the AISC 358, Chapter 2. Carlsbad PC2019-0066.Revl (PREV2020-0053) 4-17-2020 5. The plastic hinge location and their probable maximum moment for pre-qualified connections shall comply with AISC 358, Sections 2.4.2 and 2.4.3. 6. The continuity plates, their thickness and attachment to column, for pre-qualified connections shall comply with AISC 358, Section K1, or tested per Section K2 of AISC 341. AISC 341-E2-6f. 7. The panel zones for pre-qualified connections shall comply with Section J10.6. AISC 341-E2-6e. 8. Bolt holes are not permitted in the protected zones of the pre-qualified connections, unless detailed in accordance with the individual connection, as per AISC 358, Section 2.6. If Bolted connection is shown to be justified show calc for gravity connection using just (2) 1" bolts. For a W18 beam just (2) bolts might now work. Provide justification. 9. Beam-to-Column Connection Requirements. The following requirements should be met for the design of the beam-to-column joints in accordance with AISC 341-E2-6b: a) The connection shall be capable of sustaining an interstory drift angle of at least 0.02 radians. b) The measured flexural resistance of the connection, determined at the column face, shall equal at least 0.80 Mp of the connected beam at an interstory drift angle of 0.02 radians. 10. Required Panel Zone Strength. No additional requirements beyond the specifications, Section J10.6, as per AISC 341-E2-6e. 11. Beam and Column Limitations. The requirements of Section 8.1 shall be satisfied, in addition to the followings: [AISC 341-E2-5a]: a) Width-Thickness Limitations. Beam and column members shall meet the requirements of Section D1 for moderately ductile members, unless otherwise qualified by tests. b) Beam Flanges. Abrupt changes in beam flange area are not permitted in plastic hinge regions, unless otherwise permitted. AISC 341-E2-5b. 12. Continuity Plates. Continuity plates should be provided in accordance with the pre-qualified connection as per Sections K1 or K2. [AISC 341-E2-6f]. 13. Column-Beam Moment Ratio. No additional requirements beyond the Specifications. AISC 341-E2-4. 14. Lateral Bracing of Beams. Both flanges shall be laterally braced directly or indirectly. The unbraced length shall not exceed 0.1 ?ryE/Fy. AISC 341-E2-4a. 15. Column Splices. Column splices shall comply with AISC 341-E2-6g, if complete-joint penetration groove welds are used. When column splices are made with bolts, they shall have a required flexural strength that is at least equal Carlsbad PC2019-0066.Revl (PREV2020-0053) 4-17-2020 to RyFyZx (LRFD) or RyFyZx/1.5(ASD), of the smaller column. The required shear strength of column web splices shall be at least equal to LMpJH (LRFD) or LMpJ1 .5 H (AS □) where LMpc is the sum of nominal plastic flexural strengths of the columns above and below the splice. 16. Not only shall the moment frame be limited in horizontal deflection as stated above, (show in calcs how much deflection is present) but the beam must also be with in code limits for deflection vertically. Provide calc to show vertical deflection using load combos to show code minimums L/180 and L/360 are achieved. ADDITIONAL 17. To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Cloud all edits. 18. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: □ Yes □ No 19. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Erich A. Kuchar, P.E. at Esgil. Thank you. Carlsbad PC2019-0066.Revl (PREV2020-0053) 4-17-2020 [DO NOT PAY-THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad (PREV2020-0053) PLAN CHECK#.: PC2019-0066.Revl PREPARED BY: Erich A. Kuchar, P.E. BUILDING ADDRESS: 2742-2752 State Street BUILDING OCCUPANCY: B/A2 Bl.lLDING AREA PORTION (Sq.Fl) Strucb.11al Revisions Air Corditioring Fire Sprinklers TOTAL VALUE Jurisdiction Code cb ... J llklg, Permit Fte by Ordinance I~ I f\t~.J;'. i Plan Cht<k fee by Ordinance L::~d l '.f!."I Z-~: Valuation Wtiplier By Ordinance Tw,e of Review: r Complete Review Reg. Mod. DATE: 4-17-2020 VALUE r Structural Only r Repetitlvefee -. I ~!'Jl Repeats r Other P' Hourlv EIIGIFee ~Hrs.@* ,, ,, ,, ~ • Based on hourly rate ($) $420.007 Sheet 1 of 1 State Street Remodel 2742 State Street Carls bad, CA, 92008 Structural Calculations -19141 Qualls Engineering Structural Engineering Services ft.}9-6 >9 -OO(o Co Greg Coleman Phone: 805-7 46-6516 fftv~ ~oon Qualls Engineering Structural Engineering Services Project: State Street Engineer: CG ------------ Correction Responses Correction 2: See added calculations on pages 5-11 for the shear transfer to the foundation. a) See revised calculations that use overstrength-amplified seismic forces. Sheet Job#: 19141 Date: b) Since the loads are amplified by omega, this is sufficient to satisfy the AC! ductility requirements. c) The base connections are analyzed as pinned, and therefore the grade beam has no special requirements between the frame footings. The wall footing that is between the columns is intended only to mitigate differential settlement/ rotation. Correction 3: Vertical seismic effects are included in the load combinations used. The strength combination envelope used encompasses combinations 1.36D+2.SE, 0.74D+2.SE, and 1.2D+1.6L,. The drift combination envelope used encompasses combinations 1.36D+E and 0.74D+E. Correction 4: Per AISC 341 provision E2.2, the intent of these prequalified connections is to distribute the plasticity amongst the beam, panel zone, and column. In our case, the maximum overstrength-amplified moment is 160 k-ft (see page 4 of the calculations), and the elastic capacity of the member is 0.9(50ksi)(57.6in1)/12 = 216 k-ft. Therefore, the connections will not exceed 74% of the elastic capacity, and there is no plasticity to distribute. The specified connections meet the intent of the code. Correction 5: This is not applicable, since we are not using an RBS connection. The probable maximum moment is equal to the moment at the column. Correction 6: This is not applicable, since we are not using an RBS connection. However, the specified continuity plates per detail 3/SD2 are equal to the beam flange, which satisfies the requirements of AISC 341 provision E3.6f.2.a. Correction 7: AISC 341 provision E2.6e states that there are no additional panel zone requirements. Also, we are not using an RBS connection. However, a doubler plate is specified per detail 3/SD2. Correction 8: Per page 1 of the calculations, the expected gravity loading at each beam end is 13 kips (ASD). The shear capacity of the specified erection bolts is 42.4 kips (ASD) per AISC 360 Table 7-1. Correction 9: a) The frame is still elastic at 2% drift (also see response to Correction #4). Therefore, the connection is justified at this rotation. b) See response to Correction #9a. The weld is 70ksi and the beam is S0ksi, so the flange CJP welds are sufficient to transfer the moment. Correction 10: See response to Correction #7. Qualls Engineering Structural Engineering Services Correction 11: Project: State Street Engineer: CG ------------ Sheet: Job#: 19141 Date: a) The specified Wl 8x35 members meet the requirements for moderately ductile members per AISC 341 Table 1-3. b) There are no specified changes in flange area. Correction 12: See response to Correction #6. Correction 13: See response to Correction #4. Correction 14: Detail 21/SD6 specifies full depth web filler and face-mount hangers along the full length of the frame beam. The wood joists are 16" deep with ¾" plywood over that. The frame beam is 18" deep. Therefore, the frame beam is braced against twist of the cross-section and meets the requirements of a moderately ductile braced member per AISC 341 provision D1.2a. Correction 15: This is not applicable, since there are no specified column splices. Correction 16; See added calculation page 1 for the gravity loading of the frame beam. The total deflection is 0.6in (L/822). Qualls Engineering 4403 Manchester Ave, Suite 203 Project Title: State Street Engineer: CG Project ID: 19141 Project Descr: 1/13 Printed· 27 APR :?0:?0, 4:35PM Steel Beam File= C:IUsers'fryDropboxl}>rqects\2019J0-1119141-11C.ALCUL-1119141_State_Street • CG.EC6 Software t ENERCALC, INC. 1983-2019, Build 12.19.12.31 ···•··. DESCRIPTION: F.6 & 1-4 Frame Beam CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-1 0 Load Combination Set : ASCE 7-10 Material Properties Analysis Method : Load Resistance Factor Design Beam Bracing : Beam is Fully Braced against lateral-torsional buckling Bending Axis : Major Axis Bending Fy : Steel Yield : E: Modulus : 50.0 ksi 29,000.0 ksi . . . . .. 0(0 ,0 .105 )41 32) 0(0.105,0) e • j t W18x35 Span -41.50 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.020, Lr= 0.020 ksf, Tributary Width = 11.50 ft, (Deck) Point Load : Lr = 1.320 k @ 13.0 ft, (PHP-1) Point Load : Lr = 1.320 k @ 24.0 ft, (PHP-2) Varying Uniform Load : D= 0.0->0.1050 k/ft, Extent= 0.0 --» 20.750 ft, Trib Width= 1.0 ft, (Wall Above) Varying Uniform Load : O= 0.1050->0.0 k/ft, Extent = 20. 750 --» 41 .50 ft, Trib Width= 1.0 ft, (Wall Above) DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Mu : Applied Mn • Phi : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Overall Maximum Deflections Load Combmabon Span +O+Lr 1 Vertical Reactions Load Combinabon Support 1 Overall MAX1mum 12.881 Overall MINimum 3 954 DOnly 6.589 +O+Lr 12881 +D+0.750Lr 11.308 +0.600 3.954 Lr Only 6.291 0.528 : 1 W18x35 131.730 k-ft 249.375 k-ft +1.200+1.60Lr 0.000ft Span# 1 Maximum Shear Stress Ratio = Section used for this span Vu : Applied Max.·-· Defl 0.6061 Support 2 12.483 3 954 6.589 12 483 11010 3.954 5894 0.301 in Ratio= 0.000 in Ratio= 0.606 in Ratio = 0.000 in Ratio = Location in Span 20.750 Vn • Phi : Allowable Load Combination Location of maximum on span Span# where maximum occurs 1 ,656 >=240. 0 <240.0 822 >=180. 0 <180.0 Load Combination Support notation Far left is #1 Design OK 0.113: 1 W18x35 17.973 k 159.30 k +1 .200+1 .60Lr 0.000 ft Span# 1 Max. • + • Defl Location in Span 0.0000 0.000 Values in KIPS Qualls Engineering Sheet: 2 -"---- Structural Engineering Services Project: State Street Job#: 19141 Engineer: CG --"-'~--------Date: 04/28/20 Lateral Distribution (Quonset) N-S Roof 37 Grid Area Load Lenoth or# Cols A 464 1,705 3 D 1,620 5,953 2 F.6 1,658 6 092 2 J 502 1,845 25.25 plf or#/col 568 2,976 3 046 73 System sscc OMF IMF WSW ~ Wood shcarwall updated to ]Ml' Qualls Engineering Structural Engineering Services Frame Drifts Allowable drift = 2% Load based onR= 6.51 Building Grid Load 'kios/coll A 1.46 Main B 4.00 L1 3.40 L2 6.72 Quonset D 2.98 F.6 3.05 R 3.5 4.5 4.5 2.5 3.5 4.5 Sheet: 3 ~--- Project: State Street Job#: 19141 Engineer: __::cC:..:cGe._ ______ _ Date: 4/02/20 Adj. Load Height (ft) Type Cd 6 (in) 6. (in) lkios/coll 2.71 23.33 OMF 3 3.54 5.60 5.78 25 IMF 4 4.28 6.00 4.91 14 IMF 4 3.01 3.36 17.47 12 sscc 2.5 2.78 2.88 5.53 16 OMF 3 2.60 3.84 4.40 10.5 IMF 4 2.40 2.52 ~ Added IMF Qualls Engineering Sheet: 4 -'----- Structural Engineering Services Project: State Street Job #: 19141 E ngineer: _C_G _________ _ Date: 4/02/20 Frame Strength (Envelope of 1.36O+2.SE and 0.74D+2.SE and 1.2D+1.6L,) Load Case/Load Combination End Offset Location > Load Case ,o, Load Combination ~ Modal Case ~ro.7375 ft fl ft ~-------~ .... I s_rre_ng_th ______ .... __ 11 Max and Min .... H Component I Major lf2 !Ind M3) ShearV2 ldomentM3 Load Case/Load Combination ·I OispJay Location 0 1 Show Max Done [ J-cnd ] [ 40. 7625 length r ◄ 1.5000 <I) V,, = 159 kips j I I! A CD\ [n = 2-1-9 kip-fr fnd Offset Location kip 0 Load Case OJ Load Combination Modal Case l I-End l 10.0000 --ft ~' Slre_ngth ____ ~•] I Maund Min ,. )r Component I Majo( r,12 and M3) ShearV2 b Moment IA3 ,, Display Location l~ Show Max Done [ J-End ] j s.02so fl l ength f 10.5000 ft ¢M,. = 1-19 kip-fr l.lin z 10.434 kip at 9.0250 fl Qualls Engineering Structural Engineering Services Project: State Street Engineer: ..:::Cc=G ______ _ Sheet: -"'----5 __ Job#: 19141 Date: 4/02/20 Frame Baspelates Building Grid Type A OMF Main B IMF L1 IMF L2 sscc Quonset D OMF F.6 IMF Col-to-Plate Weld Combination: 1.36D + 2.5E Fixity Pinned Fixed Fixed Fixed Fixed Pinned QV" = 1.36(3.8)+2.5(4.4 kips)= 16.2 kips Vu (k) 4.0 7.9 6.7 17.5 6.4 16.2 <DV" = 1.392kli(6 sixteenths)(2 sides)(15.5in) = 259 kips DCR = 0.08 --------- Mu (k-ft) Tu (k) 0 0 87 1.5 45 0 210 0 47 7.4 0 0 ~ ;\JJcd I I\11' www.hllti.us Company: Specifier: Address: Phone I Fax: E-Mail: Specifier"s comments: 1 Input data Anchor type and diameter: Effective embedment depth: Material: Proof: Stand-off installation: Anchor plate: Qualls Engineering CG Heavy Hex Head ASTM F 1554 GR. 36 3/4 he,= 12.000 in. ASTM F 1554 Design method ACI 318-11 / CIP eb = 0.000 in. (no stand-off); t = 0. 750 in. ; E = 0 psi; fyk = 35998 psi; YMs = 1.100 Page: Project: Sub-Project I Pos. No.: Date: ,:iis., Profis Anchor 2.6.6 6 State Street 4/29/2020 Profile: I, x ly x t = 20.000 in. x 12.000 in. x 0.750 in.; (Recommended plate thickness: calculated (0.039 in.)) W shape (AISC); (L x W x T x FT)= 17.700 in. x 6.000 in. x 0.300 in. x 0.425 in. Base material: cracked concrete, 4000, fc' = 4000 psi; h = 24.000 in. Reinforcement: tension: condition B, shear: condition B; edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (D.3.3.4.3 (d)) Shear load: yes (D.3.3.5.3 (c)) Geometry [in.) & Loading [lb, in.lb) z: Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan www.hilti.us Company: Specifier: Address: Phone I Fax: E-Mail: Qualls Engineering CG 2 Load case/Resulting anchor forces Load case: Design loads Anchor reactions [lb] Tension force:(+ Tension, -Compression) Anchor Tension force Shear force Shear force x 1 0 4050 4050 2 0 4050 4050 3 0 4050 4050 4 0 4050 4050 max. concrete compressive strain: -[%ol max. concrete compressive stress: -[psiJ resulting tension force in (x/y)=(0.00010.000): 0 [lb] resulting compression force in (x/y)=(0.00010.000): 0 [lb] 3 Tension load 1:115;.1 Profis Anchor 2.6.6 Page: 7 Project: State Street Sub-Project I Pos. No.: Date: 4/2912020 ' y Shear force y 0 0 . X 0 0 Load Nua [lb] Capacity ♦ N, [lb] Utilization PN = Nu.f♦ Nn Status Steel Strength* NIA NIA NIA NIA Pullout Strength* NIA NIA NIA N/A Concrete Breakout Strength** NIA NIA NIA NIA Concrete Side-Face Blowout, direction** NIA NIA NIA NIA * anchor having the highest loading **anchor group (anchors in tension) Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor { c) 2003-2009 Hilti AG, FL-9494 Schaan H1lti is a registered Trademark of HiHi AG, Schaan www.hilti.us Company: Specifier: Qualls Engineering CG ,:i,s., Profis Anchor 2.6.6 Page: 8 Project: State Street Address: Sub•Project I Pos. No.: Phone I Fax: Date: E-Mail: 4 Shear load Load v •• [lb] Capacity ♦ V, [lb] Steel Strength• 4050 Steel failure (with lever arm)* N/A Pryout Strength.. 16200 Concrete edge failure in direction "'"' N/A "'anchor having the highest loading "*anchor group (relevant anchors) 4.1 Steel Strength Vsa = 0.6 Ase,V futa $ Vs1eet~Vua Variables Ase,V (in.2) 0.33 Calculations V., (lb] 11623 Results V.,(lb] 11623 4.2 Pryout Strength ACI 318-11 Eq. (D-29) ACI 318-11 Table D.4.1.1 fu1a [psi] 58000 $ steel t V.,[lb] 0.650 7555 V., [lb] 4050 7555 NIA 163982 NIA Vcpg = kcp [ c::cco) \jl ec,N \jl ed,N 'I' c.N \jl cp,N Nb] tjl Vcpg ~ Vua ACI 318-11 Eq. (D-41) ACI 318-11 Table D.4.1.1 AN, see ACI 318-11, Part D.5.2.1, Fig. RD.5.2.1(b) ANcO = 9 h~1 "'"·" = (1 +~e")s1.o 3 he1 \jl ed,N = 0.7 + 0.3 ( ~;~:) S 1.0 \jl cp.N = MAX(Ca.min, 1.5he1) s 1.0 Cac Cac N, = 16 A a "1: h~3 Variables kcp h91 [in.) ec1,N [in.) 2 12.000 0.000 \jl c,N Cac [in.] k, 1.000 16 Calculations ANc [in.2] ANcO [in.2] \jl ec1 ,N 2385.00 1296.00 1.000 Results Vcpg {lb] $ concrete $ seismic 234260 0.700 1.000 ACI 318-11 Eq. (D-5) ACI 318-11 Eq. (D-8) ACI 318-11 Eq. (D-10) ACI 318-11 Eq. (D-12) ACI 318-11 Eq. (D-7) ec2.N [in.] 0.000 " ' 1.000 I.If ec2,N 1.000 1.000 Input data and results must be checked for agreement with the existing conditions and for p1ausib11ity1 PROFIS Anchor { c} 2003-2009 Hilli AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Ca min [in.] 1, [psi] 4000 \jl ed,N 1.000 ~ V,,, [lb] 163982 412912020 Utilization Pv = Vu.f♦ Vn Status 54 OK NIA NIA 10 OK NIA NIA N, [lb] 1.000 63648 V.,[lb] 16200 www.hilti.us Company: Specifier: Address: Phone I Fax: E-Mail: 5 Warnings Qualls Engineering CG 1:115;.1 Profis Anchor 2.6.6 Page: 9 Project: State Street Sub-Project 1 Pos. No.: Date: 4/29/2020 Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the loading! Input data and results must be checked for agreement with the existing conditions and for plausibility! Condition A applies when supplementary reinforcement is used. The ¢> factor is increased for non-steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength. Refer to your local standard. • Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! • An anchor design approach for structures assigned to Seismic Design Category C, 0, E or Fis given in ACI 318-11 Appendix D, Part 0.3.3.4.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Part 0.3.3.4.3 (b), Part 0.3.3.4.3 (c), or Part 0.3.3.4.3 (d). The connection design (shear) shall satisfy the provisions of Part D.3.3.5.3 (a), Part D.3.3.5.3 (b), or Part D.3.3.5.3 (c). • Part 0.3.3.4.3 (b) / part 0.3.3.5.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Part 0.3.3.4.3 (c) I part 0.3.3.5.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Part D.3.3.4.3 (d) / part D.3.3.5.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension I shear obtained from design load combinations that include E, with E increased by Q0• Fastening meets the design criteria! Input data and results must be checked for agreement with the existing conditions and for plausib1l1ty ! PROF\S Anchor ( c) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan www.hilti.us Company: Specifier: Address: Phone I Fax: E-Mail: 6 Installation data Qualls Engineering CG Anchor plate, steel: ; E = 0 psi; fyk = 35998 psi Profile: W shape (AISC); 17.700 x 6.000 x 0.300 x 0.425 in. Hole diameter in the fixture: dr = 0.813 in. Plate thickness (input): 0.750 in. Recommended plate thickness: calculated (0.039 in.) Drilling method: Hammer drilled Cleaning: No cleaning of the drilled hole is required 0 3 ~ - 1 1.500 Coordinates Anchor In. Anchor 1 2 3 4 X -8.500 8.500 -8.500 8.500 y -4.500 -4.500 4.500 4.500 10.000 c .• C+x C+y y 1:11-;~1 Profis Anchor 2.6.6 Page: 10 Project: State Street Sub-Project I Pos. No.: Date: 4/29/2020 Anchor type and diameter: Heavy Hex Head ASTM F 1554 GR. 36 3/4 Installation torque: - Hole diameter in the base material: -in. Hole depth in the base material: 12.000 in. Minimum thickness of the base material: 13.000 in. 10.000 4 - - 'l. 17.000 1.500 Input data and results must be checked for agreement with the exishng cond1hons and for plausibihtyl PROFIS Anchor ( c) 2003-2009 Hllti AG, FL-9494 Schaan Hilti is a registered Trademark of Hitti AG, Schaan 0 0 "'! ~ 0 0 0 <!l 0 0 --: a, 0 0 0 <!l 0 0 "'! ~ www.hilti.us Company: Specifier: Address: Phone I Fax: E-Mail: Qualls Engineering CG 7 Remarks; Your Cooperation Duties 1:115;.1 Profis Anchor 2.6.6 Page: 11 Project: State Street Sub-Project I Pas. No.: Date: 4/29/2020 Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c) 2003-2009 Hi\ti AG, FL-9494 Schaan Hilli is a registered Trademark of Hilti AG, Schaan Qualls Engineering 4403 Manchester Ave, Su~e 203 Beam ar grid 3.5, G-J 12 Printed: 2 APR 2020. 9.59AM Steel Beam File = C-\Users\Fry'J)ropbox\J>rojectsl2019J0-1119141--1\CAI.CUL-1\SOG&E.ec6 Software I ENERCALC. INC. 1983.2019. Suki 12.19.1231 DESCRIPTION: Rigging Beam CODE REFERENCES Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-10 Material Properties Analysis Method : Load Resistance Factor Design Beam Bracing : Completely Unbraced Bending Axis: Major Axis Bending Fy : Steel Yield : E: Modulus : 50.0 ksi 29,000.0 ksi .. I. JR) D(0.02 L~0~-~1 ~-----~-------~ W 12x14 Span = 9 . 1 70 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Load(s) for Span Number 1 Point Load : L = 8.0 k @ 4.580 ft, (SDG&E Eyelet) Uniform Load : D = 0.020, L = 0.10 ksf, Tributary Width= 1.0 ft, (Roof) DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Mu : Applied Mn • Phi : Allowable Load Combination Location of maximum on span Span # where maximum occur.; Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Overall Maximum Deflections Load Combination Span +D+L 1 Vertical Reactions Load Combination Support 1 Overall MAXimum 4619 Overall MINimum 0.094 DOnly 0.157 +D+L 4 619 +D+0.750L 3.504 +0.60D 0094 L Only 4 463 0.831: 1 W12x14 31.425 k-ft 37.800 k-ft +1.20D+1.60L 4.585ft Span# 1 Maximum Shear Stress Ratio = Section used for this span Vu : Applied Max.•.• Defl 00951 Support2 4 611 0.094 0,157 4.611 3 497 0.094 4 454 0.093 in Ratio = 0.000 in Ratio = 0.095 in Ratio = 0.000 in Ratio = Location in Span 4 585 Vn • Phi : Allowable Load Combination Location of maximum on span Span# where maximum occurs 1, 182 >=240. 0 <240.0 1157 >=180. 0 <180.0 Load Combination Support notation Far left is# 1 Design OK 0.114:1 W12x14 7.329 k 64.260 k +1.20D+1.60L 0.000 ft Span# 1 Max • + • Defl Location in Span 0.0000 0000 Values in KIPS Qualls Engineering 4403 Manchester Ave, Sutte 203 Beam at grid ,\, 10-11 13 Printed: 2 APR 2020, 10:59AM Steel Beam File = C.1Usm\fry\Oropbox'Projects\2019J0-1119141-11CALaJL-1\19141_State_Stleet . CG.EC6 Software I ENERCALC, INC. 1983-2019, Build.12.19.12.31 . ···•··. DESCRIPTION: Lofty Coffee Light Support CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-10 Material Properties Analysis Method : Load Resistance Factor Design Beam Bracing : Completely Unbraced Bending Axis : Major Axis Bending L 01 ( ) • W14x22 Span = 27.170 ft Fy : Steel Yield : E: Modulus : 50.0 ksi 29,000.0 ksi . . . I ) • A lied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : L = 0.10 k/ft, Tributary Width= 1.0 ft, (Lights) DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Mu : Applied Mn • Phi : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Overall Maximum Deflections Load Combination Span +D+L 1 Vertical Reactions Load Combination Support 1 Overall MAx1mum 1659 Overall MIN1mum 0180 DOnly 0300 +O+L 1659 +0+0.750L 1 319 +0600 0 180 L Only 1.359 0.826 : 1 W14x22 17.210 k-ft 20.834 k-ft +1 .200+1.60L 13.585ft Span# 1 Maximum Shear Stress Ratio = Section used for this span Vu : Applied Max.•.• Deft 0.2606 Support 2 1.659 0.180 0300 1.659 1.319 0.180 1.359 0.213 in Ratio= 0.000 in Ratio= 0.261 in Ratio= 0.000 in Ratio= Location in Span 13.663 Vn • Phi : Allowable Load Combination Location of maximum on span Span# where maximum occurs 1,527 >=240. 0 <240.0 1251 >=180. 0 <180.0 Load Combination Support notation : Far left is # 1 Design OK 0.027: 1 W14x22 2.534 k 94.530 k +1.200+1.60L 0.000 ft Span# 1 Max • + • Defl Location in Span 0.0000 0.000 Values in KIPS PERMIT REPORT Revision Permit Print Date: 09/08/2021 Job Address: 2742 STATE ST, # A, CARLSBAD, CA 92008-1628 (City of Carlsbad Permit No: PREV2020-0060 Status: Closed -Finaled Permit Type: BLDG-Permit Revision Work Class: Residential Permit Revisii Parcel#: 2031811900 Track#: Applied: 04/23/2020 Valuation: $0.00 Lot#: Issued: 05/13/2020 Occupancy Group: #of Dwelling Units: Project#: DEV2019-0048 Fina led Close Out: 07/14/2021 Bedrooms: Bathrooms: Project Title: STATE STREET COMMONS Plan#: Construction Type: Orig. Plan Check#: PC2019-0066 Plan Check#: Description: STATE STREET COMMONS: DEFERRED TRUSS (E-REVIEW) FEE BUILDING PLAN CHECK REVISION ADMIN FEE MANUAL BLDG PLAN CHECK FEE Property Owner: STATE STREET COMMONS, LLC 2659 STATE ST, # 100 CARLSBAD, CA 92008-1627 (619) 840-7721 Total Fees: $297.50 Total Payments To Date: $297.50 Building Division Inspector: Final Inspection: CoApplicant: C2 BUILDING GROUP 107 S CEDROS AVE, # STE 220 SOLANA BEACH, CA 92075-1994 (858) 232-0213 Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov AMOUNT $35.00 $262.50 $0.00 Page 1 of 1 APPLICATION MISSING FOR THIS PROJECT 1