Loading...
HomeMy WebLinkAboutDWG 332-8L; RP 92-10; FISH HOUSE VERA CRUZ; L1-L9PROJECT OWNER: MR. REX BUTLER LOCATION MAP CITY OF OCEANSIDE VICINITY MAP JI RAILROAD . -GRAND AVE. -- -- --SITE -... \ d ~ t;:; t;:; 1--1--:j r w w ~ uJ w w "' I= ~ "' t;; t;; 0 V, V) <( . - Ill w ~ :z z V, ti: 0 0 w __J t;; > V) V) "' .. w i:5 "' j V) <( w w.. 0 :,: w.. ~ 0 UJ "' ~ -OAK AVE. - . - -- CARLSBAD FISH HOUSE, INC. 41 7 CARLSBAD VILLAGE DRIVE CARLSBAD, CALIFORNIA 92008 (619) 434-6777 f,!OT TO SCALE C.ITY OF VISTA - CITY OF SAN MARCOS '--\.'--_,-.,____, ...---- CITY OF ENCINITAS -- "' ' --\ ~ I" CARLSBAD VILLAGE DRIVE I-'\ I/ w w > w c2 I= 0 Vl 0 <;J !=1 :z i:5 o._ "' 0 <( ii: :i: - ~ NO SCALE ., 'E .......-1~ - (r • • • ~j -ti SHEET INDEX - SHEET TITLE SHEET Nn TITLE SHEET L-1 IRRIGATION PLAN L·2 PLANTING PLAN L-3 PLANTING AND IRRIGATION DETAILS L-4 PLANTING AND IRRIGATION DETAILS L-5 PLANTING AND IRRIGATION GENERAL NOTES L-6 PLANTING AND IRRIGATION SPECIFICATIONS L-7 PLANTING AND IRRIGATION SPECIFICATIONS L-8 PLANTING AND IRmGATION SPECIFICATIONS L"9 I HEREBY DECLARE THAT I AM THE LICENSED DESIGNER OF WORK FOR Ti-1IS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANlJARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS ANO SPECIFICATIONS BY THE CITY OF CARLSBAD IS CONFINED TO REVIEW ONLY AND DOES NOT RELIEVE ME, AS THE LICENSED DESIGNER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. THESE PLANS HAVE BEEN PREPARED IN SUBSTANTIAL, CONFORMANCE WITH THE APPROVED LANDSCAPE CONCEPT PLAN, WATER CONSERVATION PLAN, FIRE PROTECTION PLAN, AND ALL CONDITIONS OF Af:eRQVAL RELATED TO LANDSCAPING. " Jjif !-.· . "'"' 0· 2c, ~a . GENERAL NOTES APPROVED 1. THE CONTRACTOR MUST NOTIFY THE CITY PLAN CHECK CONSULTANT (619-438- 1161) EXT. 4221 72 HOURS (THREE WORKING DAYS), PrHOR TO STARTING CONSTRUCTION. 2. THE LANDSCAPE OR IRRIGATION CONTRACTOR IS TO VERIFY EXISTING P.SJ. AT JOB SITE PRIOR TO INSTALLING LANDSCAPE IRRIGATION SYSTEM. VERIFICATION SI-IALL BE MADE WITH THE APPROPRIATE WATER DISTRICT. 3. 4 . ALL REDUCED PRESSURE BACKFLOW PREVENTER$ SHALL BE TESTED AFTER INSTALLATION, RELOCATION, OR REPAIRS BY A CITY APPROVED CERTIFIED TESTER. CALL 438-0218 FOR A LIST OF CITY APPROVED CERTIFIED TESTERS. DEVELOPER/OWNER IS RESPONSIBLE FOR SUPPL YING A COPY OF THE TEST RESULTS TO THE CITY DEPARTMENT OF UTILITIES AND MAINTENANCE, 405 OAK STREET. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING BUILDING AND PLUMBING PERMITS PRIOR TO COMMENCING WALL CONSTRUCTION AND IRRIGATION, RESPECTIVELY 5. IRRIGATION SYSTEMS FOR INDIVIDUAL PARCELS SHALL HAVE POINTS OF CONNECTION FOR THE SYSTEM BETWEEN THE WATER METER AND WATER SERVICE RISER INTO BUILDING AND AHEAD OF ANY WATER REGULATING DEVICE INSTALLED FOR BUILDING. ae a us 6/25/U3 --------------------,..-----------------....;;..;_;,_ design group Lin~"'' 11chillc111e ■ mi11nqen111111nning -· 4 2~2 ~•rdiri slri!I. soil" -· -- car,i,t caljarnil 91008 pi\o,e@llllU·!l!i "AS BUIL T 11 Tl1LE_________ DATE REV!EVED BY1 I I . 5/tl.{..<,(. ~ ~/1/Lt3 DATE APPROVED FOR PLANTING AND IRRIGA1'ION ONI_,Y, INCLUDING PRECISE LOCATION OF' PLANTING AREAS. \ I ENGINEERING PLANUiECKER INSPECTOR DATE i ~---+---+-----------+-----+----j~·----+----lfsHml1 CITY OF CARLSBAD J SHEET9l Lb::1J PLANNING DEPARTMENT I 9 _J_ -·---+---+----------------+---+----t--+----1 ::==='-'=============:',.;::=~ 1---+-----+-----------------t-----t---+----+--·- 1---+---------t------------------t-----t---+-----·<------,I FISH HOUSE VERA CRUZ JIT~ SHEET "-p~..,.._~9-2~""-'1{1-'--,'W:_'7._.' ~~·~,,.___ .. ~-~-7-/-93 .'l ASSiJ-sfANT,IPLANNl,';;;N=G-!:./:::::'.:::ll]R=E=C=T=□=R====::;-;::::==D=A=T=E=::- DATE INl'!lAL ,--EN<llNF.F.R OF WORK REVISION DESCRIPTION lE BY· PROJECT NO. DRAWING NO. l--0_11_n:_~1_NI_TI_AL--+_O_A_n:_~I_Nl_ll_AL----t D SY:--~ OTHER APPROVAL CITY APPROVAL ',fl) BY, RP 92-10 332-BL w > -a: C w ~ ...J ...J -> C ~ en ...J a: ~ • ·- ~ \/ / / PROPOSED BUILDING 12" 'll1L \111' -1 '~ / / -- / / / // IRR.4.,i,11oi--l a:>f..J'TROL.L~( 1..Jfa.LL.:~ ~C-iWT). Ff.:::•Vli?IS, I lo ✓ Ci}fLJ,,T Ci,.J>4fFc.-ro J..FPR"v'is Loc~11c f..l I - -, ,- J_: t4 L,,_ ______ _ • ~ ! 111 ~l~0. ~Llm/;jJ;; I i \ ' ',. IRRIGATION LEGEND F 3/4 ····- SYMBOL 0 ~ e;i _,,.,,, .. [:RPEfl --•••••• '-· -__J ,---~ CD 0 @ ® ~ (§] IRsl @ POC I I. l .. L..J. SYMBOL GALLONS P~R MINUTe 2/3 1/Z 1/3 1/4 EST SST ADJ. MANUFACTURER DESCRIPllON MODEL NO. RAD PSI F 3.14 I 213 L & A.AINalRD SHRUB POP UP 1806 10·LA W/PCS 10' 30 1. 75 -· ·-······-·-., ....•. .-.. iORO I NElli:clM DRIP TIJBING TLDL-9-12 30 _g GPM ---·-· .. ------ -~~'"" ",. -·····--·-~ .. I I -~~ . I -1---·-~ ~ ...... ,_ -~~,H•,••=-- -..... ,., ... ~--·••"-~ -·-·~---·· -~--~•-----~ --.. ""'-~ •---- MANUFACTURER DESCRIPTION MODEL NO. REMARKS DETAIL Kl NG BROS_ INC_ BALL VALVE WL T--BALL VAL VE LINE S1Z~ B/ L-4 HARDIE 6 STATION CONTROLLER TCs61N INTERIOR INSTALLATION c;; I L-4 HARDIE REMOTo CCNTROL VALVE 700-_75', ,00-1· $121;; PE;R PLAN A/ l,.-4 ANY LATERAL LINE TYPE 1120 PVC PIPE CLASS 200 SIZE PER PLAN, BURY 12" DEEP FEBCC REDUCED PRESSURE BACKFLOW ASSEMBLY 11/4" 82SY-BV-S E/L-4 ANY MAIN PRESSURE LINE. SCHEDULE 40 SIZE PER PLAN, BURY 18" DEl=P, BURY 24" BB.OW PAVED !,UR'"•" • ANY MAIN PRESSURE LINE. SCHEDULE K COPPER SIZE Pm PLAN, BURY 18" DEEP ANY PVC SLEEVE. SCH 40 (2X DIAMETER OF THE LATERAL) TORO I NETIFIM 120 MESH DISC FILTER W / VALVE DFVO75-120 SEE PLAN FOR LOCATIONS, I/ L-4 PLACE IN ROUNa VALVE BOX TORO I NETIFIM INLINE PRESSURE REGULATOR PAV CONTRACTOR TO SELECT I/ L-4 BASED UPON CIRCUIT GPM AND REQUIRED PSI TORO/ NETIFIM FLUSH VALVE 11 GALLON) TL050MFV H/ l,.-4 TORO I NETIFIM AIRi VACUUM RELIEF VALVE TLAVRV SEE PLAN FOf, LOCATIONS, PLACE IN ROUND VALVE BOX, PHDVIDE 4' D AMETE~1 LOOP TORO I NETIFIM TREE WATERING LOOP TLDL 9·12 PER EACH TREE. WILKINS PRESSURE REGULATOR 11/4" 5t::O SERIES SET 0) 65 PSI E/L-4 s"EE Pl.AN FOrl LOCATION RAINBIRD RAIN SENSOR DEVICE RAIN CHECK RAINBIRD QUICK COUPLER VALVE 44 RC 0/ L-4 POINI OF CONNECTION 1120 PVC PPE ,7!;,ASS 200 11 .,.., HEADE:R UE F J.ICfl~I !"\DID /ILL PPE TO BE 3/ 4" J/L-4 1 '---~ ,,_ -STATION I.D. NUMBER -t-~--+-(o~(-. __ GPM 12" ~ -TECHLINE TUBE SPACING -J ii ii ------VALVE SIZE ~ ~(--INSTALLATION DIRECTION OF TECH LINE EMITTER TUBING I I I I : I I . 1/2 1/3 1/4 _60 .40 _,ai2_ __ • - ..... ~,·-·· .... ,J.,~ DETAIL Fil.-,~, -,-~ C/L-4,JIL-4 -~~"·"·~·-.. ·- / / / t I / • • ---~a;:).ie i -·1 ... ---------........ L~ .... 12" .;rJ] ftt, ·"' 111 fflt,, ~lk llilTES; I. Trll:PE SIJJ.U BE fm FIIT'.NGS CR CONNEGTIOtlS TO Oll-lER F/-clUTIES BElWEEH THE METER 1-JW 1H;:; PJCKFLO'ff .ASStJ.(BLY. 1. TIE BAGl'fl_OW ASSDlmX MUST BE lil5TA)lil) A MINIMUIJ CF _SIX IIJL'HcS (b') I/IJ HOT TD EXCEED A wll:UUU Of mo fill (2') FROM TH[ IIElrn EXCFPI iHERE THIS WOUL'l Rl'QU:R[ lht ::~/(:i(f-U)','1 /-::;58-(~LY lO 81: 11\ST/-J.lED 1)1 Tl!F. -P~ELC l'.iGl!T--OF-WA'I". IN WHICH CASE, THE I?.ACKr~c,w A...%DfBLY MUST ·ti:: 1:1srAll£lJ A HAXB,11,JU OF TWO fEl'T (2') lllSlDE THE PPCH"ifff [IMF.. n-:F. p.,i,,C/<f-lOW /,SSFJml.l Wt:t HO':, lH·1.l.l1:..;'.,t }J-jr' cm.ct.11.lSfNlCE'.i SI:. ltlsr.11.llD !)j TH~ PUBLIC PJC,fT--{)f-WA'r'. . 3. Trf'[ K P.\RD DR TrFE L HIRD C()?PER OR !R,!.SS WE]J sou:ER Joli/rs OR 1HCsfADED fl1TiNGS uusr r,, USE) P.F.1WW1 n;. llmJl AND THE B\CKFLOW ASSEJJ8L_Y, 4. PR[CEDIIIG TIIE 111:irnrn OIIE SHlff Off VN.Vf., t,CllHEtno11 WUST of W.Dc Y~TH A COFFrn CR B_'\I:";$ fJStR TD A C()PP'11 OR f;AAIS oo· ~;xm. ·sHvr Off '//l_Vf. IMY B, PRECEDED ~( A c: .. rER cR 511AS!i !ll'PLE lilD/0R A eR,'-5 I_/WII. R'.'.ic)\ U11sr Df. Of o\!•r1Clcll )J)l{;iH 11\\1 lllf. [;(J!f)!j or TIIE ll\CKFLOW "'3SfJJfJLY IS lWF'~YE lliCHES (It) 10 r,,l~Tr-·c!X IHt>.ES (JI,) IWIE GR1'DE 111 AH N!S\ IIOT SUBJECT TO FlCODING. ' F•)llO's·,:1G lHE IIUIHR 1110 ,HUT Off VJ.LI'[. lHE COlil'ECTICII ~UST B, WDE WITH A IX:PPER CR El1J.SS w· rr...o0w fO A COFFER OR BPASS PJcER TO A C()PPER OR 6R/-SS 9c· EJBDW. s:·t::-[Ff \IAI..Yf. U,W !:E FOU.OY,TD P.Y A COPFi:R CR CRiS::3 llll'l-'ll.E'. AND/OR A PRASS UN!Ctl. kr.::'"E.R 1.1lJS'r !l~ Of SiJr!-lCIDri LE.NG'tH 1r1,1 lH£ 13()rJ'()).( Of' Im; 11/,[;J<Fl,(J'/!' J..S'.,F}..(fll.'( IS rm'rt: lliCHES (:/) TO IHIFIY-SIX INCHES (3?) !BOYE ,~.m, 1:11)1 /REA 1101 SUS.:ECT 11) FlOOclliG. 6. IF EN;KFWW ASSrnBLY IS 10 f.E !IIST'11ED O!I A SLOPE '!'!Ti A l~RIZONT!l TO l'ERllC.\L R.A]O or ,:I OR Gf.EA8l. A TWO FOOT (?.') HIG!I RETIIHIIJG Will MUSf BE EUil! SUFROIJIIDl'IG rn::: ,'-.SS812l':' ON fr-IRE£ :IDE;S 'ili'll'.-! THE OPE-UNG otl T}i[ C,OYftl S1DE OF THE SLOPE. TK:T<E l,,IJS'f G::: A µpn,11.rJ TWO FOOT (.?.') HORl7.0fili!t Cl [_,!JWJCE 5F.Ti\".:J:Jl n-:[ PHJJ!llNG WN 1.. 1/:0 le[ ,)rnUJ'! ASS[J.<elY_ ASSWBLY WUST BE L0OmJ nl AN IJifA IIOT SIJBJ,CT fO n_DCOlliJ. - 7. OHLY REDUCED ~P-[SSURE PRIUC:PL.£ 8-ACKF;_C'/f PRF.Vf.Nl",011 ASSEMBUES 'rlllliC\I f-L,!,,VE tEE:N AITR.CTl"ED BY TI-!E STATE OF CNJFURll!A DEPARTMENT CF HEN.TI-I SUNICSS Nm lNi.l.SB-'ID )~UIW':IPM .. WXITR 1"-ISTP.ICT \'ml Fl':: USFD Oil W,&Jrn SEJ'l.1C'2:: 'ltTHIN ·rnr: SE.k'\1CE N'D. OF TI-ff U$.l.S2)D l,IU\llC:PJ,l_ WATER DISTRlCT. ft ,_ 'I'• ..'.."L' not w . ___ ,, ______ ----- ,·,· .,, ?-~./ aeda~us desl1n IIDDP i.a· ltlllltflt• --·-1111 liilij 11111!. iii I 1 2'' rn1n1rnurn Jf3" n-1 ox1 rn um ~-'.::..,' required on 2H or smaller . ..... ...... DATE INITIAL . . - ' 6/25/93 SCALE: 1/B",-1'-0" FEET, I HAS BUIL TN APPROVED FOR PLANTING ! AND i IRRIGATION ONLY, i I INCLUDING PRECISE TITLE DATt LOCATION OF PLANTING . REVIE',/ED BY, AREAS. I INSPECTOR DATt [IT] CITY OF CARLSBAD SHIEETS 2 PLANNING DEPARTMENT !!:) FISH HOUSE VERA CRUZ I //1RRIGATION PLAN . APPRn~~4'& ff 11r1... · _'. ASSlSTANT .PLANNING DIR£CT□R 7-/-93; DAlr--· DATE INITIAL DATE INITIAL OWN BY: PROJECT NO. DRAWING NO. I I CHKD BY: 1nlol ......... ENGINEER OF WORK REVISION DESCRIPTION OTHtR APPROVAL CITY APPROVAL RV',/D BY• RP 92-10 332-BL ll•fllll••ml . . w > -~ ~ ...J ...J -> \ j en ..J 5 to N B FELT EXPANSION JOINT FINISH SURFACE'--- CONCRETE BASE ' J 1,. 1 " I 10 " RIVER ROCK SEATWALL PROPOSED BUILDING . . . .. '"'x~ .. y :\7>_.Xy . " . ---·~---.--,.1!;;:·; ... x ,> / x> -' . '1<. ,,. 1 " -----::.~ RED BRICK CAP #3 BAR CONT. IN TOP OF WALL BOND BEAM #3 BARS VERT. @ 32" o.c. LOCAL RIVER ROCKS SET W/IN EXPOSED MORTAR 2 • #3 BARS CONT. @ 3" ABOVE BOTTOM OF CONC. FOOTING FINISH GRADE COMPACTED SUBGRAGE c___ ___ CONCRETE FTG. TO REACH 2000 PSI AT 28 DAYS. ., I / I Co to / ,,. ---1-;,<4 iea,wa:t:> Hi:J.r~ 7?, / FJ?'Avi tc,.. E:R.1 r+:: . P£v'1>kt A.L1tj / fL..6-~l 1J1-1q P.;.,r,::-.v, ~IC,!<'.. Al 4''2'l1--]C~-TE:. ~. ',·· ·. '• . •f ,--'.~ ► 1 •. ! --~, . / / / • TRASH ENCLOSURE, i1)"M,.f( ,i1-,,. ) ,,.!.dt.f'-':J/, / / /' •• 'If ., @) • • " I . ._ / ;.~ :,,.,.,.J,i ,..-..11,.i('" c,~., , ..... ,,~~ JrM;r( 4.;,t:,,..u......, f'Y..4 ~-~ ' •• •• ------------•• ___ ....;:~._,,L.---' 6" A.C. PAVING ,I•.,. .,. ... .,. ·-,. ' ' ... -.. -.. .., .., -.. ... . ., .,, I I',-.,.,,.,. .. -.. ... -.. ., FINISH GRADE -..,,,,_,,< ... >,',',',',-LOCAL RIVER ROCKS SET W/IN :-.. .._ .... '-'-., ;--;...;<<-EXPOSED MORTAR. '-.._ '-., =;;,l~e!!!!!E~""'1l:(.,, ,.. ., ,-.,, .... . ............ -.. .._,..,.,..._-'.,,, .. . . ; -·· •..,.,.,,. _, (1) -#3 REBAR CONT., LOCATt AS SHOWN. : . 'f'.",1· ~ ' ,' ,' . -:, --•-. '. .._",/-..> . -··t·· _.._~ ,..,..· ..,."_,.-___ O C ,; ·-._; ·.·-·, ...... ·',',' C N RETE FTG. TO REACH 2000 PSI ' · • .',',' @ 28 DAYS. ... \ \ ~ ~ ~ ~ \ \ ~ ... ... ~ '.,,. ,I' ,I.,.,.,,. .. .,. ',,., ~ ... ... \ ~ ' ... ~ ~ ' ' ~ ~ . ., ,. .,. ,. .,. .• . .,. ,. ,. ., ~ ' . ... .... ~, ~ 8" I Scale· 1 1 /2" ~ 1 '-0" &IVER ROCK CURB ·-Scale: 1 l/Z"=l'-0" aedalus ~eslon group illllrtlll 1111!,hn• lllll•!f•-•1 -----ililiiiiij ilili. iiil DATE INITIAL 11.ill. Cll'1rll II■ ENGINEER OF WORK 111111 hl/llM!ll , l . I . D ··PLANT LEGEND Symbol f----:;:::=::::::-------· Cupaniopsls anacardlodes Carrot Wood Tree • 2 24" eox Std. Trunk 3· Per PIMJ 0 Arecastrum romanzo/1/anum Queen Palm ---·--7''---· Phoenix roebelenli Pigmy Date Palm 2 II Hgt. per brown trunk footage. u I ( \ / ' SHRUBS· \ • Exisling planls '-..;..-/ Aspidistra elatior •·- ED e- 0 0 Casi Iron Plant Grew/a ca/Ira Lavender Starflower Ligularia 1ussilagina 'Aurea Maculata' Leopard Plant Nepro!ep!s corditolla Southern Sword Fern -Osmanthua fragrans Sweet Olive Raphiolepis ind/ca 'Ballerina' India Hawthorn Strelitzia reginae Bird of Paradise .Tradescantia andersoniana SpiderwDrt ~.-Trachelospermum }asminoides 0W Star Jasmine GRQllN □COVER; 5 5 Gal 1 3 15 Gal Espalier 7 1 Gal. 1 0 1 Gal 4 15 Gal Espalier 29 SGal 7 5Gal 9 1 Gal 1 Gal Plan I 2' O.G. ~--···-·--+Pelargonium peltatum 'Ba/can' ~ Ivy Goranium Plant 12" O.C From Flats Color to be 50% pink and 50% red. Phormium tenax rubrum (Dwarf) Dwarf Red Flax Limonium perezil Sea Lavender §]--· SEASONAL ANNUAL COLOR o~-BIM>inopsis spp. No Common Name · 12 1B i•PLANT 12" o.c. 6 1 Gal 1-Gal 4" POTS 1 Gal LAND, ARCH. TO SELECT · AT THE TIME OF PLAN ,.,) . '.o :, .. • . it ~ .,.'r 6/25/93 SCALE: 1/8"=1'-0" FEET APPROVED FOR PLANTING '' AS BUILT'' I AND IRRIGATION ONLY, I INCLUDING PRECISE TITLE DATk • LOCATION OF PLANTING REVIEVED BY, AREAS. ' '1 INSPECTOR DAT!i: CT![] CITY OF CARLSBAD ~u 3 PLANNING DEPARTMENT 9 .. _ FISH HOUSE VERA CRUZ ' ' PLANTING PLAN I /) , ! APPRo,~· ., fJ.IA 1 -/--zt//c,, t, 1/ :♦k.1 , (,. ,, ,,. ,' ,1•~ ~·' 7-I-~ ~L ASSf~ANT PLANNING DIRECTOR DATF- OWN BY: PROJECT NO. DRAWING NO. o ... rr IN\111\L OA'\t INl11AL CHKD BY: REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RV'v/D BY• RP 92-10 332-:IBL -'=- ' ' 2 F:'· ® Q) CD LC EDGE OF PLANTING_/ NOTES 1) ALL GROUND COYER TO BE PLANTED IN A TRIANGULAR GR!O. 2) PLANT ON CENTER SPACING PER PLANTING PLAN. GROUND COVER PLANTING .----111OUFICI'! (TO HEADER) 4" -e• FROM PAVING 0 SUB-SURFACE, PRl;SSURE COMPENSATING TUBING. © !MISSION POINT. © PVC PIPING A FITTINGS. © START CON- NECTION (SEE DETAIL C /L-4 ). (';'\ LINE FLUSHING \::,./ VALVE IN SUMP BOX OFF OF PVC FOOTER. (SEE DETAIL H/L-4 ). @EMISSION POINT SPACING: (SEE PLANS I. LEGEND). TECHLINE DRIP TUBING NOTE: PROVIDE 6" MINIMUM CLEARANCE BETWEEN FILTER AND GRAVEL. TECHLINE DISC FILTER W /REGULATOR IN BOX 0 Tech Line DISC FILTER. ©PVC FEMALE ADAPTER. ©PVCSCH.80 UNION (TxT), 4 PVC MALE ADAPTER. © PVC MAINLINE. (TYP.) © 12" x 18" BOX (LID NOT SHOWN.) (;'\ 3/4" PEA V GRAVEL SUMP. © BRICK SUPPORT (TYP.) 0 PRESSURE REGULATOR ' □i 0 LINE FLUSHING VALVE. 0 9" ROUND BOX WITH LID. © FINISH GRADE. 0 PVC PIPING FROM FOOTER. © 3/4" PEA GRAVEL SUMP: 1 CU. FT IN SAND. 1.5 CU. FT. IN LOAM. 2 CU. FT. IN CLAY. FLUSH VALVE PEDESTAL MOUNT CONTROLLER PER LEGEND----, r--------WAl.L l()UNT CONTROLLER PER LEGEND NOTE: FINAL CONTROLLER LOCATION SIIALL BE PER THE OWNER MD LAND• . . SCAPE ARCHITECT INSTALL PER HANUFACTUR£R INSTRUCT IONS. ANCHOR CONUT TO WAll F-.Y W /GIWI. Pl'E CLAW'S IJStj(I fllSThBIS Al'l'ROl'RIAl"E FOR TYl'E OF WAil. PANT TO l'AlCH ITYP.) D ! .;1-PROVIDE THREADED CONNECTION 0 ENTRY PORT INTO THE CONTROLLER HOUSING. . '( 1~-t.J-----H-120 VOLT WIRE W/IN ELEC. COl,l)UIT @ w w U) ® lff------+--i-IRRIGATION CONTROL WlRE W /IN ELEC. CONDUIT FtNISR GRADE 1' IN TURF AREA, 2" IN GROUND COVER MEA------1 w Q C u = w ~ ,- i! -w w "' . 8 0) u -~ w ~ ~ -w ;,; 2000 PSI CONCRETE BASE PROVIDE SWEEP ELLS 6" CLEM All SIDES----------' CONTROLLER 11-~;i ---~---1,-1-: 1 I I I I I LAWN & SHRUB AREA POP-UP SCII 80 l'VC NlPPl.f:, I.P.NGTII AS l!EQUilll 'll (l) SCI! ~O l'VC TXT Ii LL (1) MAllLEX STI\Cl'T !of.I. SCI! 80 l'VC Nll'Pl.11, Lf,NGTII AS I! EQIJ IIH!IJ (!) MAHI.EX STREET El.I. SCI!. ~o. l'VC SXSXT ·1.rn: on. SXT ELL · PVC IATERAI. I.I NH PER 1,1:GliND @ r.", PRESSURE REGUI.ATOR OPTIONAL.. ~ SEE Pl.AN & LEGEND 0 "Y" STRAINER 0 SHORT BRASS NIPPLE 4 BRASS UNION 6 lliREAOED BRASS RISERS 0 FINISH GRADE @THRUST BLOCK 5 16 TYPE K CDPPE PIPE 1i BRASS 3 1-----.!i:,'t,,0 ~ ' l.lNION , "' @ ;,..,-r~ 8 ;:: •::-t---115 1i• 0 0 RECU:ED PRESSURE BACl<FlOW DEVlCE W/ GATE VALVES & TEST COCKS f£lGHT PER LOCAL CODES ro,a:ETE FCXJJN3 96%COMPACTEC SUBGRAOE PI/C COUPLING TxS• PI/C MAINLINE.SEE LEGEND e 10 MIL PIPE WRAP TYP. 1 • ALL BRASS TO B: TYPE "K" OR "L" HARD BRASS WITH SOLDERED JOINTS OR lH'IEAOEO FITTINGS. REDUCED PRESSURE BACKFLOW (SEE DETAIL ,-t~ , FOR ADDITIONAL INFORMATION) ~----FINISH GRADE ® CD REMJTl:CCMAOI.VALVE. ® VALVEBOX,SIZEASREQUIRED. (i_: PVC, SCH. BO LNION. (4' P'IC, SCH. 80 NIPPLE. (TYP.). ·--· .~ ( 5 PVC, SCH.40 MALE ADAPTER: ,r 6 ' PVC LATERAL LINE, .. 7 . PVC MAINLINE. ( 8 ' PVC, SCH. 40 TEE. ( 9' PVC, SCH. 40 ELL ~ 14 REMOTE CONTROL VALVE ® <i]> @ @ <Bi @ @ @ @ WATI:RPROCFccnECTORS. CONTROL WIRES 'fi/18' PIGTAILS. BRICK OR CONG. SUPPORTS ALLAROUNO. COAPACTEDSL83RADE. FINISH GRADE. 2" IN G.C. & 1" IN LAWN AREAS. 2' MINIMUM. SEE LEGEND OR SPECIFICATIONS. 1 CU. Fr OF PEA GRAVEL • 6" CONCRETE -,.----...c...----+- CURR OR QUICK COUPLER PER LEGEND SET 211 ABOVE FINISH GRADE IN GROUND COVER AREAS AND IN LAWN AREAS SET BELOW GRADE IN ROUND PLASTIC VALVE BOX MARKED (Q.C.) QUICK COUPLER. SIDEWALK @ ■111111 © !E w ~ "' .., . "' : .. "' +• "-: i:: ~ "-w c:, ; '-\ ,· , ... • .' .. •' .. =--~'-BRASS NIPPLE, LENGTH AS REQ'D. BRASS COUPLING CUBIC FOOT CONCRETE TRUST BLOCK BRASS NIPPLE, LENGTH AS REQ'D BRASS NIPPLE, LENGTH AS REQ'D SCH 80 PVC FEMALE ADAPTER SCH 80 PVC NIPPLE, LENGTH AS REQUIRED COMPACTED SUBGRADE 1) ALL BRASS FITTINGS SHALL BE RED BRASS. c::~rr~~==1C-~fll======GAT" OH IIAI.I, VALVli l'l:H 1.1,GllNU ~-l-1---------PVC N!Prl.E, l.l!NG'111 AS RliQ'D ______ UNION ( P'IC ) :·t:a.j r[• ~-;;_1.J.ll,;;;=~---PVC Nil'Pl.l'S, U:NC111 AS r-.--;;;o.....-~,_, r: Rl'QIJI IU'U .:::> i,J. :8? ---r PVC 1'11MAI.I' ADAl•Tl'II, 2 IU'Q'D ~-,,.-----"""-'',---~ ,•vc MA IN I.[ NE 4" MIN. CLCAR ONI' CUBIC HXlT J/4" ROCK --lllt!CK AIWUND VAi.VE l!OX l'lilUMHTl:1, i'OH su1•1•01rr NOT!:: I) Cl.OSI, NI l'l'I.ISS SIIAI.I. MlT Ill' USl'll. 2) C:ATI: OH l!AI.I. Vi\l.VES AHP. NOT TO Ill' l NSTALl.i:IJ WI TII IN I IU<I 1:ATI ON CON· TIIOI. VAi.Vi, l!OXl:S. QUICK COUPLER @ BALL VALVE ® 0 TechLlne EMITTER TUBING, © TechUne TUBING ELBOW. 0 POLYETHYLENE TUBING. 0 TechLlne 3/4" MALE ADAPTER. I APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLAN1'1NG AREAS. 6/25/ 3 '' AS BUILT" TITLE_________ DATE REVIE\JED BY, © PVC TEE (SxSxT)[====~=====~=========~====~======~~::::::::r:::[J[[[[][[[[[I[[[[Tr=_.==~::I~NS:;P;::E:;'.C::T~O::R=:::::==:::::====::-D;:A;:'.T~E=';::-1 .-4 CITY OF CARLSBAD I SH9EETJ. © PVC LATERAL i----t----t-----------------..-+---+---+---+----1 PLANNING DEPARH1ENT HEADER OR t----;---+----------------+---+---+--+----1 FOOTER. 0 FINISH GRADE. r,;\ SEE SPECIFICATIONS \V ANO LEGEND. FISH HOUSE VERA CRUZ PLANTING & IRRIGATION DETAILS /'/ APPROVEQ,,.~ -.,L../,'?PJ' . ASS!STAtfl/PLANNING DIREtT □R ?-l-73 ~ DATE TECHLINE START CONNECTION DATT; INlnAL REVISION DESCRIPTION DATT: INlnAL DATT: INlnAL DWN BY: ---PROJECT NO. CHKD BY: __ _ I DRAWING NO. . 332-BL ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL RVWD BY• RP 92-10 ® ® Q) @ CD ® ® I-..&' ., (2) CINCII TIES, TACK TO STAKES TO PIHlVENT & ' lf... ~--j -SLTl'PING ' I __...--IX4 IU'IJWOUD BHACll I.llNGTII /IS REQUIHEI) / i ....---~----J!1" WJl)r, ELASTIC WEBBING, TIE ONTO BR/ICE / V--TN /IN S-LOOP TO PREVENT DAMAGE '1'0 TIWNK / / -----------(2) 2" OTA. X 8' LONG TIH'/\Tlm I.OIJCEl'OI.E ~ ..... ce:cy·.c .. -•v __ -PINE STAKES FOR 5 GAL. TRE[;S -...j.-ff't-..,.~[~!11 .,,.,, ...._ (2) 2" DIA. X 10' LONG TRl:A'l'ED LODGl'POI.f: . -, lill-V ' I ; "1111 '-::.--imir PINE STAKES' FOR l S CAL. -24" llOX TIU:ES. 111111 "" c'/'. '/ v.;~illl I SET STAKES OUTSIDE ROOTll/11.1 .• rrm~;/~ .~ ~rrM ~'~ NOTES: ~ ~, ~ -I )_TN_S_T_/\L_L_'_l'R_[_[ -T-I T-•S_A_N_D_S_'l_"/\K_E_· S-O_N_I. Y_T_O - 1/ :;//4,;,,:: /2 PROl'l.:I\ LEVEL TO 1101.D 'l'Rl'E Ul'IUGIIT. PRO· l'EH IIEIGIIT IS 6" A80V[: POINT Wlll!RE 'lllli TRl:E WILL SN/IP TO /IN UPnlGIIT POSITION BY l'l'SELI' IF TOP JS PULLED TO ONE STfJE AS Ii' IVINIJ LOADED AND "l'IIEN RliL[,/\Sl'll. 2) 'l'l{l'l!S SUPPLrnD WITH TOl'S TOO l.AHG!i FOR THUNKS lU SUPPO!n' Sil/ILL BE PllUNIJl AS nIRf:CTEU BY LAND. /\RCII. TO IHiDUCr, CROWN Wl' lGIIT OR PRUNl'IJ TO A Nl!II LEADL'IL DO NOT Rl'MOVc L/\TEllALS Al.ONG THUNK. TREE STAKING (5 gal. -24" box) -----~, -FACE OF BUILDING, POST, OR COLUMN -----------------__________ -· SPREAD ON WALL AND SECURE _____ ,----------· _ .--· REMOVENURSERYSTAKE --------------------v------/~-_,..---· 2· MULCH LAYER (SEE PLANTING NOTES) r~/- t 11 J I I 11 ,l II fill'! , II SET ROOTBALL TIGHT TO FOOTING. REMOVE ,-,,, ANY BUILDING MATERIALS THAT MAY BE / UNEARTHED WHEN DIGGING OUT PLANTING / PIT. --4" HIGH WATER RETENTION BASIN ·~~,, II 1 ) _ _,. FINISH GRADE ·:\:I · 11 / _,..,,,..----PlANT FERTILIZER TABLETS, PER PLANTING 1/ roTES. I /~/ AVOID ROOTBALL SETTLING. SEE PLANTING I / / NOTES FOR BACKFILL MIX. • • •' :·:,.,,.,·,' ,·, .··.-\.:-~: -1 -~ A-ANT~.-1 ~~ SHRUB PLANTING --------SET SIIRUB CROWN l" ABOVE P,lNISll GR/\UE ~---2" MULCH LAYER PIJR PL/INTI NG NOTES SCAIUPY SOIL /\LONG SIDl1S AND llOTTOM OF !'LANT! NG PIT. ~--5 GALI.ON 'J\l. 2i" BOX TRHS ,s' A ~-~IJ:,~ -:{n nn PLANTTNl: l'LAN(sl h [;;:;· _ 2" MULCII LAYER (., PLANT cROWN Of TRl]E I" /\BOVE ) "'l\ "J • y-' I' I NI SI I GRADE ) ,.,Q.~ ' " . 0.. ) ~0v' \f 4" IIIGII W/\Tl'll Rl,TllNTION MSIN PLANT ll00TBALI., PRErARE PER PLANT! NG NOTES /f!NISII GRAIJE I ~,,;;;;;:i,::'.:/';:-_l'L/\NT flilt'J'I LI Ztm TAIH,ns l'UR j, :! 4~ j// _ ___.-SCARIFYSOILALONGSIDESANDBOTTOMOF ~ -%ow. Fl-p~~'1/'"'•-PLANTING PIT. -ii:'J.JJ'!rj~ ~-·;.~-rn~ir/ ! ~ ~ ~--""'l,I~ Wl "i, y: 0, ''" ';;·-l!_!f PLANTING NOTES ; '= ,;, ✓v".~ , 11 • PREPARED B/\CKfll.L MIX. PUOUI.~ 6 =-__ -.-::.~._rn·_·'.· .,•.• .. · v-;-;;:;...,, :.. ~ SETTLE BACKFILL l'RJOR m PLANT-f!l yyy " ING "JO AVOIIJ llOOTBALL SETTLING, 15 ~ "'. srn PI./\N'l'JNG NO'I'~S l'Olt BACKFILL z ~ '.1.-•. ¢(:i-• MIX. I ~-; 0 -~· ~ ,-~-----SCARIVi SOIL ALONG SllJES AND JI~·-. J .1111 ~ z .. ,:.~·' .'/ I!!" ~ '. / t~-~: -,! "· !l[ \I~~~= ~---··. ····'•' @ VINE/ESPALIER PLANTING © NOTE• · o'· ;• o, ./.' BOT1\lM 01' PLANTING PIT. USE EXPOXY TIES· ATTACH TO WOOD WITH NAILS ANO TO STUCCO WITH EPOXY CEMENT. -"!,---------~-----' JSEE PLANTNl j r NOTES r NOT!: @ l) PRUNE 11Uol'S AS lllRl:CTl:D BY LANDSCAPE AllCIIITliCT, TREE PLANTING (5-GAL THRU 24" BOX) 6/:5/93 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. 11 AS BUILT 11 TITLE ________ _ REVIE\JED BY• INSPECTOR DA'E : ' ---D-A-J+-E-- .. ~--+----+------------+-----1----1---------l-----l ["SHml5 c ITY o F c ARLSBAD fsJ=1E6ETs I l___b=Qj PLANNING DEPARTMENT L ~=:-....':::==========='-====: FISH HOUSE VERA CRUZ PLANTING & IRRIGATION DETAILS _,,..,·"-;, t----+----+-----------------+-----+---+----+-----.1 DV,1,J°BY: I PROJECT NO. DATE INITIAL DATt INITIAL OATt INITIAL CHKD BY: __ _ REVISION DESCRIPTION B RP 92 10 ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL L':R'-.'V'..c\,/'.'..cD~'---'Y..:,•-=="'-.l ~----···-=--I DRAWING NO. 332-8L -· I ,, Ii II IRRIGATION NOTES 1 . 2. CONTRACTOR SHALL INSTALL IRRIGATION SYSTEMS THAT ARE COMPLETE AND FUNCTIONING IN EVERY WAY. PLANS ARE DIAGRAMMATIC AND APPROXIMATE. PRECISE LOCATION OF HEADS SHALL BE FIELD ADJUSTED TO MEET MINOR VARIATIONS IN PLAN. 3. CONTRACTOR SHALL CHECK AND VERIFY ALL SITE CONDITIONS, UTILITIES, AND SERVICES PRIOR TO TRENCHING. 4. CONTRACTOR SHAU. CHECK AND VERIFY STATIC WATER PRESSURE READING OF 90 PSI AT STREET PRIOR TO BEGINNING OF WORK. NOTIFY LANDSCAPE ARCHITECT OF ANY DISCREPANCY. 5. POINT OF CONNECTION (POC) SHALL BE AT METER. 6. CONTRACTOR SHALL FIELD VERIFY SIZE OF WATER METER BEFORE WORK COMMENCES, MINIMUM SIZE TO BE 1", CONTACT LANDSCAPE ARCHITECT IF METER IS SMALLER THAN 1". 7. SET PRESSURE REGULATOR AT _§Q_ PSI. 8. DIRECT BURIAL CONTROL WIRE SHALL BE 24 VOLT. SINGLE CONDUCTOR SOLID COPPER, PLASTIC INSULATED CABLE RATED FOR DIRECT BURIAL APPLICATIONS, UF, UL APPROVED, 14-GAUGE (MINIMUM) PILOT WIRE, 12-GAUGE (MINIMUM) FOR COMMON GROUND RETURN WIRE. SIZE OF WIRE FOR RUNS OVER 100' LONG SHALL BE PER MANUFACTURER'S SPECS. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR SLEEVES ANO CHASES UNDER PAVING, THROUGH WALLS, ETC. UNLESS OTHERWISE NOTED. SLEEVING SHALL BE MARKED AT EACH END OF FLATWORK OR WALLS BY A PAINT DOT. 1 0. CONTRACTOR SHALL NOTE LOCATIONS OF TREES ON PLANTING PLAN AND SHALL ROUTE IRRIGATION PIPE AND PLACE HEADS TO PREVENT CONFLICTS WITH TREE PLANTING. GROUP VALVES IN BOXES, PARALLEL TO EACH OTHER, IN PLANTING AREAS. LOCATE PIPE ALONG EOOE OF Pl.ANTING AREAS WHEREVER POSSIBLE. 11. FLUSH ALL PIPES CLEAN PRIOR TO INSTALLING SPRINKLER HEADS UNLESS OTHERWISE NOTED. 1 2. ALL HEADS TO BE 2' FROM CURBS AND WALKS, AND 6' FROM BUILDING UON. 13. PROVIDE ANTI DRAIN VALVES OR CORRECT LINE SIZE WHERE FIELD CONDITIONS DEMAND, PER PLANS, AND/OR AS REQUIRED. 14. CONTROL WIRES SHALL BE BUNDLED WITH ELECTRICAL TAPE AT 8'-0" INTERVALS AND BURIED BENEATH MAINLINE WHERE POSSIBLE OR AT THE SAME DEPTH AS MAINLINE ALONG EDGES OF PLANTING AREAS. 1 5. CONTRACTOR SHALL ADJUST ALL IRRIGATION HEADS TO COMPLETELY COVER PLANTING AREAS WHILE AVOIDING WALKS, BUILDINGS, POSTS, COLUMNS, AND WINDOWS. 1 6 . AU. TRENCHES SHAU. BE WETTED ANO RECOMPACTEO TO 90% MINIMUM UNDER FLATWORK AND 85% IN PLANTING AREAS. 1 7. SYSTEM CONTROLLER SHAU. BE CONNECTED TO A RAIN SENSOR SHUTOFF DEVICE, PER PLAN. 18. CONTRACTOR'S MAINTENANCE PERIOD SHALL tlQI BE TERMINATED UNTIL THE FOLLOWING CONDITIONS ARE SATISFIED AND APPROVED BY THE LANDSCAPE ARCHITECT: 19. A. VALVES SHALL BE WIRED TO CONTROLLER IN SAME NUMERICAL SEQUENCE AS INDICATED ON PLANS. B. PROVIDE PLASTIC SEALED DIAGRAMMATIC PLAN OR SYSTEM IDENTIFYING STATION NUMBERS AND AREA THEY WATER; MOUNT INSIDE EACH CONmOO.ER. C CONTRACTOR SHALL MOUNT IRRIGATION SCHEDULING GUIDELINES (PROVIDED) IN A PLASTIC SLE:EVE IN THE CONTROLLER BOX. D. "AS-BIJIL T" DRAWINGS SHALL INCLUDE LOCATIONS OF ALL MAINS, VALVES, SOURCE OF ELECTRICAL POWER FOR CONTROLLER CLOCK, CONTROL WIRE SLEEVES. AND BELOW GRADE HEADS HAVING A R/\.DIUS OF 30'-0" PLUS. LOCATE BY DIMENSIONING FROM TWO FIXED POINTS (ON REPRODUCIBLE MATERIAL). (CONTRACTOR MAY USE A BLUEPRINT OF THE SPRINKLER PLAN AND EDIT IN PERMANENT RED INK FOR THE AS,BUILT DRAWING.) (CHOOSE 1) PROVIDE THE FOLLOWING TOOLS AND MATERIALS AS PART OF THIS CONTRACT: QUANTITY DESCRIPTION 1 EQUIPMENT OPERATION MANUALS AND GUARANTEES. 1 PLASTIC SEALED DIAGRAM OF SYSTEM AREAS. 1 AS-BUILT DRAWINGS. 1 SETS OF AUTOMATIC CONTROLLER KEYS FOR EACH CONTFIOUER. ..1 QUICK COUPLER VALVE KEYS ANU 1 t:ACH HOSE SWIVEL /\ND BIBB ASSEMBLIES. 1 WRENCH FOR DISASSEMBLING EACH TYPE OF SPRINKLER HEAD SUPPLIED. ..1 SCREWDRIVER FOR ADJUSTING EACH TYPE OF SPRINKLER HEAD SUPPLIED. MANUAL VALVE KEYS. HOSE BIBB KEYS. 20. IRRIGATION SYSTEM IS SHOWN DIAGRAMMATICALLY. LOCATE ALL PIPE AND EQUIPMENT WITHIN PLANTING AREAS. GROUP PARALLEL PIPE IN SINGLE TRENCHES WHERE POSSIBLE. 21 . ANY SUBSTITUTION MUST BE APPROVED IN WRITING BY LANDSCAPE ARCHITECT. 22. 23. 24, ALL IRRIGATION MATERIALS AND PROCEDURES SHALL CONFORM TO All LOCAL, MUNICIPAL, AND STATE LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK AND ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE NOTES /\ND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE IRRIGATION CONTRACTOR. IRRIGATION CONTRACTOR SHALL GUARANTEE THE ENTIRE IRRIGATION SYSTEM TO BE FREE OF DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM FINAL ACCEPTANCE BY THE Q',';NER. IRRIGATION CONTRACTOR SHALL MAINTAIN THE SYSTEM FOR A PERIOD OF 30 DAYS ANO SHALL SCHEDULE WATERING AS REQUIRED TO MAINTAIN HEALTHY PLANTS. PLANTING NOTES 1 . 2. LANDSCAPE CONTRACTOR SHALL RECEIVE THE SITE WITHIN PLUS OR MINUS .1 o FEET OF FINISH GRADE U.O.N. THE PLANTING PLANS ARE DIAGRAMMATIC. MINOR ADJUSTMENTS IN PLANT LOCATIONS AND TYPE MAY BE MADE AT THE DISCRETION OF THE LANDSCAPE ARCHITECT. 3. ALL PLANT MATERIAL SHAU. BE SUBJECT TO THE APPROVAL OF THE LANDSCAPE ARCHITECT, OWNER, OR OWNER'S REPRESENTATIVE. AND REPLACED UPON REQUEST BEFORE PLANTING IF JUOOED OF POOR QUALITY. 4. THE LANDSCAPE CONTRACTOR WILL COORDINATE HIS WORK WITH THE OTHER TRADES AND MAINTAIN DRAINAGE DURING CONSTRUCTION. 5. PLANT QUANTITIES AND AREAS SHOWN ON LEGENDS ARE FOR CONTRACTOR'S CONVENIENCE IN ESTIMATING ONLY. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING PLANT MATERIALS TO COVER ALL AREAS AS SHOWN ON PLANS. 6. LANDSCAPE ARCHITECT, OWNER, OR OWNER'S REPRESENTATIVE SHALL APPROVE FINAL PLACEMENT OF ALL TREES, SHRUBS, AND VINES PRIOR TO PLANTING. 7. TREE AND SHRUB PITS 15 GALLONS OR SMALLER SHALL BE TWO TIMES ROOTBALL DIAMETER WIDE ANO EQUAL WITH ROOTB/\LL DEPTH. TREE AND SHRUB PITS FOR 20" BOX AND LARGER SHALL BE 1-1/2 TIMES ROOTBALL DIAMETER WIDE AND EQUAL WITH ROOTBALL DEPTH 8. TREE GUYING SHALL BE DONE AT CONTRACTOR/OWNER DISCRETION (PER DETAIL). CONTRACTOR SHALL BE RESPONSIBLE FOR THE TREE'S STABILITY DURING THE LENGTH OF THE GUARANTEE PERIOD ALL STAKING AND GUYING MATERIALS SHALL BE REMOVED AT THE END OF THE 1-YEAR TREE GUARANTEE PERIOD. 9. NITROLIZED ORGANIC AMENDMENT SHALL BE BUTLER'S MILL ORGANIC LANDSCAPE MIX PLUS. OR APPROVED EQUAL 1 0. PLANTING BACKFILL MIX FOR ALL CONTAINER PLANTS EXCEPT FERNS, AZALEAS, CAMELLIAS, OR AS NOTED IN PLAN (SEE NOTE# 19). ON SITE SOIL NITROLIZED ORGANIC AMENDMENT AGRIFORM 18-18-6 FERTILIZER AGRICULTURAL GYPSUM IRON SULFATE 6 CU. YDS. 4CU. YDS 1 LB. 4 LBS. 1 LB. PLANTING BACKFILL MIX FOR ALL FERNS, AZALEAS, CAMELLIAS SHALL CONSIST OF 1/3 EXISTING SITE: SOIL. 1/3 NITROLIZED ORGANIC AMENDMENT AND 1/3 THOROUGHLY WETTED PEATMOSS, MIXED TO A UNIFORM PLANTING MEDIUM, AND WATERED IN AFTER PLANTING WITH TERRA-SOL OR APPROVED EQUIVALENT WETTING AGENT. 11 . ALL PLANTS 1-GALLON SIZE OR LARGER SHALL RECEIVE /\GRIFORM 21-GRAM 20-10-5 FERTILIZER TABLETS AT THE FOLLOWING RATES: 1-GALLON: ONE 5-GALLON: TWO 15-GALLON: THREE BOXED TREES: ONE PER 112" CALIPER PLACE TABLET 6 8" DEEP AND IN CONTACT WITH ROOTBALL. ' 12. ALL PLANTS INSTALLED FROM FLATS SHALL RECEIVE ONE AGRIFORM 5-GRAM 20-10-5 TABLET EACH, MIXED WITH A HANDFUL OF MULCH AND BACKFILL. 13. BOUG/\INVILLAEAS SHALL BE PLANTED WITH INTACT ROOTBALLS. NO BROKEN ROOTBALLS WILL BE ACCEPTED. 14. AU. PLANTS EXCEPT BOUGAINVlll.AEAS PLANTED FROM CONTAINERS SHALL HAVE THEIR ROOTBALLS SCORED WITH A SHARP TOOL TO A DEPTH OF 1" IN THREE LONGITUDINAL INCISIONS AT LOCI\ TIONS SPACED AROUND THE ROOTBALL BEFORE PLACING PLANT IN PLANTING HOLE. 15. ALL TYING MATERIALS AND MARKING TAPES SHALL BE REMOVED AT THE TIME OF PLANTING. 1 6. STAKES SHALL BE REMOVED FROM VINES, THEN TRAINED TO WALL, POST, OR COLUMN PER PLANTING DETAIL 1 7. CONTRACTOR SHALL VERIFY ALL PLANTING AREA SIZES AND THE EXTENT OF 18. 19. THEIR PLANTING. IF ANY DISCREPANCIES OCCUR, PLEASE BRING THESE TO THE ATTENTION OF THE OWNER AT THE TIME YOUR BID IS SUBMITTED. ALL BOXED TREE PITS ARE TO BE EVALUATED FOR DRAINAGE, TEST PITS SHOULD BE LOCATED THROUGHOUT THE SITE TO SUPPLY A GOOD CROSS SECTION OF THE ENTIRE PROJECT. THE TEST CONSISTS OF DIGGING TEST PITS 1 FOOT WIDE BY 18" DEEP AND FILLING THE PITS TWICE OVER A 48 HOUR PERIOD. IF THE WATER LEVEL HAS NOT MOVED DOWN AT LEAST 1/4' PER HOUR OR MORE. THE SITE SHOULD BE CONSIDERED TO HAVE POOR DRAINAGE CHARACTERISTICS. THE CONTRACTOR IS TO CONTACT THE LANDSCAPE ARCHITECT AND A DRAINAGE PROGRAM WILL BE DEVISED FOR THE SITE'S SPECIFIC CONDITIONS. THE FOLLOWING SHALL BE APPLIED FOR 1,000 SQ FT. OF PLANTING AREA AND TILLED INTO THE SOIL TO A DEPTH OF 6" FOR /\LL LANDSCAPED AREAS WITH A SLOPE OF 3:1 OR LESS. THE CONTRACTOR SHALL USE THE FOLLOWING AMENDMENT SCHEDULE FOR B\QQING PUBP.9SES ONLY, A SOIL TEST SHALL BE MADE AS PART OF THIS CONTRACT ALL BACKFILL AND SOIL AMENDING SHALL BE PER CITY APPROVED SOIL TEST. CONTRACTOR TO SUBMIT TEST RESULTS TO CITY LANDSCAPE CONSUL TANT FOR APPROVAL PRIOR TO AMENDING SOILS. 100 LBS. OF GYPSUM PER 1,000 SQ. FT. 25 LBS. OF AGRIFORM 18-18-6 FERTILIZER PER 1.000 SQ. FT. 10 LIBS OF IRON SULFATE PER 1,000 SQ. FT. 5 CUBIC YARDS OF NITROLIZED ORGANIC AMENDMENT PER 1,000 SQ. FT. 20. NO IRON SULFATE SHALL COME IN CONTACT WITH ANY MASONRY SURFACE OR CONCRETE FLATWORK. 21. SLOPE ALL PLANTING AREAS AWAY FROM BUILDING AT 2% MINIMUM FOR 5 FEET MINIMUM, WHERE APPLICABLE. 22. LAWN AREAS SHALL HAVE A MAXIMUM SLOPE INCLINE OF 4:1, GROUND COVER TO BE 2·1 U.O.N. 23. 24 LANDSCAPE CONTRACTOR SHALL MAINTAIN ALL PLANTINGS FOR A PERIOD OF 30 DAYS, GUARANTEE ALL TREES FOR ONE YEAR, AND SHRUBS FOR NINETY DAYS: GROUND COVERS /\ND LAWN FOR THIRTY DAYS. THE MAINTENANCE PERIOD SHAU. INCLUDE THE FOLLOWING SCOPE Of WORK: A. REQUIRED WATERING TO MAINTAIN HEALTHY PLANTS B. WEEDING AND REMOVAL OF /\NY WEEDS FROM GROUND COVER AREAS. c. D. E F. REPLACEMENT OF ANY DEAD OR DYING OR DAMAGED TREES, SHRUBS, AND (,"l()LND COVER FILLING AND REPLANTING OR ANY LOW AREAS WHICH MAY CAUSE ST ANDING WATER. ADJUSTING OF SPRINKLER HEAD HEIGHTS AND WATERING PATTERNS. FILLING ANO RECOMPACTION OF ERODED AREAS. G WEEKLY REMOVAL OF ALL TRASH, LITTER, CLIPPINGS, AND ALL FOREIGN DEBRIS. H. MOWING AND TRIMMING OF ALL TURF AREAS. TURF IS NOT TO EXCEED 3" IN HEIGHT BEFORE MOWING OPERATIONS. COLLECT GRASS CLIPPINGS DURING MOWING OPERATIONS AND REMOVE FROM SITE. I. AT THIRTY DAYS AFTER PLANTING, ALL PLANTED AREAS FERTILIZE WITH 6 LBS. OF BEST FERTILIZER CO. 16-6-8 OR EQUAL PER 1,000 SQ. FT. 25. PRIOR TO THE END OF THE MAINTENANCE PERIOD, LANDSCAPE CONTRACTOR SHALL CONTACT THE OWNER AND ARRANGE A FINAL WALK THROUGH. OWNER MUST ACCEPT ALL MAINTAINED AREAS IN WRITING PRIOR TO THE END OF THE MAINTENANCE PERIOD. 26. ALL PLANTED AREAS ARE TO HAVE A 3" LAYER OF WALK-ON BARK APPLIED TO THE GROUND SURFACES. ONLY AREAS HAVING A SLOPE CONDITION OR INDICATED AS BEING TURF ARE EXEMPT FROM THIS MULCHING PROGRAM. BARK AVAILABLE @ BUTLERS MILL, PH. 745-1245. DO NOT MOUND MULCH DIRECTLY AROUND PLANT TRUNK, LEAVE AN AREA OF APPROXIMATELY 3' BARE AROUND BASE OF ALL TREES AND SHRUBS. 27. CONTRACTOR SHALL VERIFY LOCATION OF ALL UNDERGROUND UTILITIES ANO SERVICES PRIOR TO ANY DIGGING. CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR AU. DAMAGE CAUSED BY FAILURE TO DO SO. 2 8. BOXED TREES TO BE APPROVED BY O',';NER. 2 9. ANY SUBSTITUTION MUST BE APPROVED IN WRITING BY LANDSCAPE ARCHITECT, 3 0. GROUND COVER IS NOT SHOWN UNDER SHRUBS FOR GRAPHIC CLARITY. GROUND COVERS ARE TO CONllNUE TO DRIPLINE (AT TIME OF PLANTING) OF All. SHRUBS UNLESS OTHERWISE NOTED. 31. PRIOR TO PLANTING, THE IRRIGATION SYSTEM SHALIL BE FULLY OPERATIONAL. ALL PLANTING AREAS SHALL BE THOROUGHLY WATERED IMMEDIATELY AFTER PLANTING AND APPLICATION OF FERTILIZER. 3 2. THE FOLLOWING OUTLINE REPRESENTS REQUIRED SITE OBSERVATION MEETINGS FOR THIS PROJECT. THE FOLLOWING INDIVIDUALS ARE TO A TT END EACH OF THESE MEETINGS. PROJECT LANDSCAPE ARCHITECT, CITY LANDSCAPE INSPECTOR, AND A REPRESENTATIVE OF THE LANDSCAPE CCNTMCTING FIRM. A. TEST OF PRESSURE PIPE; OBSERVE INSTALLATION OF P.O.C., CONTROLLER, TRENCH DEPTHS, BACKFLOW DEVICE AND VALVES. (NO WORK SHALL BE BACKFILLED UNTIL APPROPRIATE INSPECTIONS AND TESTING HAVE BEEN COMPLETED AND APPROVED BY THE CITY). ALSO INSPECTION OF ALL IRRIGATION SLEEVES SH(HJLD TAKE PLACE PRIOR TO PAVING INSTALLATION. 8. FOUR HOUR TEST OF ALL PRESSURE LINES UNDER HYDROSTATIC PRESSURE OF 150 POUNDS PER SQUARE INCH, AND PROVE WATERTIGHT. C IRRIGATION COVERAGE TEST. D. PLACEMENT OF PLANTS PRIOR TO DIGGING PLANT HOLES. E. PRE-MAINTENANCE WALK-THROUGH, INCLUDING COUNT OF ALL PLANTS, IRRIGATION HEADS, VALVES, ETC. 33. LANDSCAPE CONTRACTOR SHALL REMOVE ALL EXISTING VEGETATION, TRASH, CLIPPINGS, ROCK, AND OTHER DEBRIS FROM THE SITE AND DISPOSE OF IT AT AN APPROVED DISPOSAL SITE. ADDITIONALLY, THE CONTRACTOR SHALL RAKE ANO FINE GRADE ALL AREAS TO BE PLANTED PRIOR TO THE COMMENCEMENT OF PLANTING OPERATIONS. 3 4. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR /WY REPAIRS MADE NECESSARY THROUGH THE ACTIONS OR NEGLIGENCE OF HIS OR HER CREW. APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCA 1'ION OF PLANTING AREAS. I 6/25/~3 "AS BUILT'' TITLE________ DATE REVJEVED BY, INSPECTOR DATE ~ ---CITY OF CARLSBAD l---+---+------------------+-----1---+---+----I ~ PLANNING DEPARTMENT f~--t-------+-----------------+---+---t-----+-----1 FISH HOUSE VERA CRUZ PLANTl!'>IQ & IRRIGATION GENERAL NOTES ,.,,.•', APPR"Q-¥,!';D /II~// ?-1.,9:::, _ __,vl/_cc· /." L Y¥-£ l---+----+-----------------+-----+---t-----t--------1 ASSR:'T ANT/PLANNING DIRECTOR DATE PATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION BY: I ~ROJECT ND. 1----CD_A_n:_,._I_N_ITl-'-A_L+-_D_An:~J_l_:_Nl-'-TI_AL----t D BY:~-~ OTHER APPROVAL CITY APPROVAL D BY, RP 92-10 ...;::........., .. , DRAWING Nt). 332-BL fu I ! .I IRRIGATION SPECIFICATIONS PART 1 -GENERAL 1.01 DESCRIPTION A, WORK DISCUSSED IN THIS SECTION INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, AND EQUIPMENT REQUIRED TO COMPLETE WORK INDICATED ON THE DRAWINGS, THE WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE BEST STANDARDS OF PRACTICE RELI\TING TO THE VARIOUS TRADES AND UNDER THE CONTINUOUS SUPERVISION OF A COMPETENT FOREMAN, CAPABLE OF INTERPRETING THE DRAWINGS, NOTES, AND THESE SPECIFICATIONS. B. IRRIGATION AND LANDSCAPE WO!U< MAY BE DONE CONCURRENTLY, HOWEVER, LANDSCAPE WORK MAY NOT START IN ANY SECTION PRIOR TO INSPECTION AND APPR(>VAL OF THE SPRINKLER WORK. C, PRIOR TO EXCAVATION FOR IRRIGATION PIPE, LOCATE ALL ELEC- TRICAL CABLES, CONDUITS, AND ALL UTILITY LINES SO THI\T PRO- PER PRECAUTIONS MAY BE TAKEN NOT TO DAMAGE SUCH IMPROVEMENTS. IN THE EVENT OF A CONFLICT BETWEEN SUCH LINES AND PIPE LOCA- TIONS, PROMPTLY NOTIFY THE LANDSCAPE ARCHITECT WHO SHALL ARRANGE FOR RELOCATION OF ONE OR THE OTHER. FAILURE TO FOLLOW THIS PROCEDURE PLA.CES UPON THE CONTRACTOR THE RESPON- SIBILITY FOR (AT HIS OWN EXPENSE) MAKING ANY AND ALL REPAIRS FOR DAMAGE'RESULTING FROM WORK HEREUNDER. 1.02 SPECIAL CONDITIONS THE GENERAL CONDITIONS ARE A PART OF THIS SECTION AND THE CONTRACT FOR THIS WORK AND APPLY TO THIS SECTION FULLY AS IF REPEATED HERE. 1.03 GENERAL REQUIREMENTS FURNISH AND INSTALL IRRIGATION SYSTEM INCLUDING, ANY INCI- DENTAL WORK NOT SHOWN OR SPECIFIED WHICH CAN REASONABLY BE INFERRED AS PART OF THE WORK, AS NECESSARY TO PROVIDE A COMPLETE AND WORKABLE SYSTEM. 1.04 WORK INCLUDED THE FOLLOWING ITEMS ARE DETERMINED TO BE A PP.RT OF THE IRRI- GATION WORK WHEN APPLICABLE TO THE PLANS. A. P.O.C. CONNECTION OF SYSTEM TO EXISTING WATER MAIN OR METER B. REVIEW OF UTILITY PLANS SHOWING OTHER UNDERGROUND FACILITIES C. TRENCHING AND BACKFILL D, ALL IRRIGATION MATERIAL AND EQUIPMENT INDICATED ON DRAWINGS E. AUTOMATIC CONTROLLER ANO ELECTRICAL CONNECTION F. WATER CONNECTION 1.05 WORK NOT INCLUDED A. ELECTRICAL STUB-OUT B. WATER METER INSTALLATION l.06 A. 1.07 A. 1.08 CODES, RULES, AND SAFETY ORDERS ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES AND REGULATIONS OF THE SAFETY ORDERS OF THE DIVISION OF INDUSTRIAL SAFETY; THE UNIFORM PLUMBING CODE PUBLISHED BY THE WESTERN PLUMBING OFFICIALS' ASSOCIATION; AND OT!lER APPLICABLE LAWS OR REGUL.l\TIONS. NOTHING IN THESE DRAWINGS OR SPECIFICATIONS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. SHOULD THE CONSTRUCTION DOCU- Mf,NTS, OR INSTRUCTION BE AT VARIANCE WITH T!lE AFOREMENTIONED RULES AND REGULATIONS, NOTIFY LANDSCAPE ARCHITECT, AND AWAIT HIS INSTRUCTIONS BEFORE PROCEEDING WITH THE ~10RK AFFECTED. PERMITS AND FEES OBTAIN ALL PERMITS AND PAY REQUIRED FEES TO ANY GOVERNMENTAL AGENCY HAVING JURISDICTION OVER THE WORK. ARRANGE FOR IN- SPECTIONS REQUIRED BY LOCAL ORDINANCES DURING THE COURSE OF CONSTRUCTION AS REQUIRED. ON COMPLETION OF THE WORK, SATISFACTORY EVIDENCE SHALL BE FURNIS!lED TO LANDSCAPE ARCHI- TECT TO SHOW THAT ALL WORK HAS BEEN INSTALLED IN ACCORDANCE WITH THE ORDINANCES AND CODE REQUIREMENTS. APPROVAL A. W!lEREVER THE TERMS "APPROVE," "APPROVAL," OR "APPROVED" ARE USED IN THE SPECIFICATIONS, THEY SHALL MEAN THE APPROVAL OF LANDSCAPE ARCHITECT IN WRITING. 1.09 SCHEDULE OF WORK A. SCHEDULE AND COORDINATE THE ELECTRICAL AND WATER,CONNECTIONS, AND THE PLACEMENT OF MATERIAL AND EQUIPMENT IN A MANNER THAT WILL EFFECT THE EARLIEST COMPLETION OF THE WORK IN CONFOR- MANCE WITH THE CONSTRUCTION PROGRESS SCHEDULE. PART 2 -DELIVERY, STORAGE, AND HANDLING 1.01 NOTIFICATION A. PROVIDE NOTIFICATION OF THE DELIVERY SCHEDULE IN ADVANCE SO MATERIAL MAY BE INSPECTED UPON ARRIVAL AT THE JOB SITE. REMOVE UNACCEPTABLE MATERIAL FROM THE JOB SITE IMMEDIATELY. 2.02 PROTECTION A. PROTECT WORK AND MATERIALS UNDER THIS SECTION FROM DAMAGE DURING CONSTRUCTION AND STOR/\GE. POLYVINYL CHLORIDE (PVC) PIPE AND FITTINGS SHALL BE SHIELDED FROM DIRECT SUNLIGHT. B. ASSUME ALL RESPONSIBILITY FOR DAMAGE TO EXISTING CONSTRUC- TION, AND RESTORE PROPERTY TO ITS ORIGINAL CONDITION SHOULD DAMAGE OCCUR AS A RESULT OF THE WORK OF THIS SECTION. C. HANDLE PLASTIC PIPE AND FITTINGS CAREFULLY AND STORE UNDER COVER TO AVOID 0/\MAGE, BEDS ON WHICH MATERIALS ARE STORED MUST BE FULL LENGTH OF PIPE TO AVOID DAMAGE. ANY PIPE THAT HAS BEEN DAMAGED OR DENTED SHALL NOT BE USED IN THE WORK. PART 3 -MATERIALS 3.01 CONDITION OF DELIVERY A. ALL MATERIALS THROUGHOUT THE SYSTEM SHALL BE NEW AND IN PER- FECT CONDITION. NO DEVIATIONS FROM THE SPECIFICATIONS SHALL BE ALLOWED. THE DECISION OF LANDSCAPE ARCHITECT SHALL BE FINAL IN THE DETERMINATION OF THE QUALITY OF MATERIALS AND EQUIPMENT. FOR ALL MATERIALS AN INVOICE SHALL BE SUBMITTED SHOWING QUANTITIES OF MATERIALS. 3.02 DESCRIPTION A. PLASTIC PIPING: ALL MAIN LINE PIPE SHALL BE AN APf'ROVED BRAND, CLASS 315 PVC. ALL LATERAL PIPE TO SPRINKLERS SHALL BE CLASS 200, TYPE 1120-1220 POLYVINYL CHLORIDE (PVC) PIPE. ALL PIPE SHALL CONFORM TO ASTM Dl785 AND ASTM D2241. B. PLASTIC FITTINGS: SCHEDULE 40, POLYVINYL CHLORIDE (PVC) STANDARD WEIGHT, AS MANUFACTURED BY SLOANE, LASCO, OR AN APPROVED EQUAL, ASTM D2464, ASTM D2466 1 OR ASTM D2467 AS REQUIRED. C. SOLVENT CEMENT: COMPATIBLE WITH PVC PIPE AND OF PROPER CONSISTENCY. NO MIXING OF SOLVENT WITH THINNER WILL BE ALLOWED. D. PIPE PRIMER: COMPATIBLE WITH PVC PIPE AND OF PROPER CONSIS- TENCY. E. CONTROL WIRES: 24 VOLT SOLID WIRE U.L. APPROVED FOR DIRECT BURI/\[, IN GROUND. BLACK 114 UF DIRECT LEAD AND WHITE 112 UF COMMON GROUND, UN!,ESS NOTED ON PLANS. F. WIRE CONDUIT UNDER PAVEMENT1 ASTM Dl785 2" PVC PIPE, SCH. 40. G. SPRINKLER HEADS: OF THE MANUFACTURE SPECIFIED IN LEGEND ON DRAWINGS, H. RISERS: SCH. BO PVC. I. VALll:E KEYS: FURNISH :TWe ·{2.) .30" GALVANIZED_ KEYS FOR ADJUST- ING REMOTE CONTROL VALVES, J. PLASTIC VALVE BOXES: CARSON, AMETEK, OR APPROVED EQUAL, K. CONTROLLER: OF THE MANUFACTURE SPECIFIED IN LEGEND ON DRI\WINGS. L. M. N. o. CONTROLLER HOUSING: AS DETAILED IN THESE PLANS, SHEET L-4 REMOTE CONTROL VALVES: OF THE MANUFACTURE SPECIFIED IN LEGEND ON DRAWINGS. BACKFLOW PREVENTER ( REDUCED PRESSl.llE ) : OF THE MANUFAC- TURE SPECIFIED IN LEGEND ON DRAWINGS. BRASS PIPE AND FITTINGS: STANDARD WEIGHT, !PS THREADED, CLASS I, 85% RED BRASS. PART 4 -INSTALLATION 4.01 A. B. 4.02 LAYOUT LAYOUT WORK AS ACCURATELY AS POSSIBLE TO THE DRAWINGS. THE DRAWINGS, THOUGH CAREFULLY DRAWN, ARE GE NF.HALI Y DIAGRAMMATIC TO THE EXTENT THAT SWING JOINTS, OFFSETS AND ALL FITTINGS ARE NOT SHOWN. JOB CONDITIONS WILL NOT ALWAYS PERMIT LOCA- TING PIPING, VALVES, AND HEADS WHERE SHOWN. WHEN THIS SITU- ATION OCCURS, IT SHALL BE BROUGHT TO THE LANDSCAPE ARCHITECT'S ATTENTION IMMEDIATELY AND THE RELOCATION DETERMINED IN A JOINT CONFERENCE. THE CONTRAC1'0R WILL BE !If.LO RESPONSIBLE FOR THE RET,OCATING OF ANY ITEMS WITHOUT F'IRST OBTAINING LANDSCAPE ARCHITECT'S APPROVAL. HE SHALL REMOVE AND RELOCATE SUCH ITEMS AT HIS OWN EXPENSE IF SO DIRECTED BY THE LANDSCAPE ARCHITECT. MINOR CHANGES IN LOCATIONS TO THE ABOVE FROM LOCATIONS SHOWN SHALL BE MADE WHEN DIRECTED BY LANDSCAPE ARCHITECT AT NO ADDITIONAL COST TO THE OWNER PROVIDING SUCH CHANGE IS ORDERED BEFORE SUCH ITEMS OF WORK, OR WORK DIRECTLY CONNECTED TO SAME ARE INSTALLED, AND PROVIDING NO ADDITIONAL MATERIALS ARE REQUIRED. EXCAVATING /\ND TRENCHING A. PRIOR TO EXCAVATION LOCATE ALL UTILITIES. SEE NOTE AT THE BEGINNING OF THIS SECTION. PERFORM ALL EXCAVATIONS AS RE- QUIRED FOR THE INSTALLATION OF THE WORK INCLUDED UNDER THIS SECTION, INCLUDING SHORING OF EARTH BiNKS TO PREVENT CAVE-INS. RESTORE ALL SURFACES, EXISTING UNDERGROUND INSTALLATIONS, ETC., DAMAGED OR CUT AS A lli:SULT OF THE EXCAVATIONS, 'l'O THEIR ORIGIN.l\L CONDITION AND IN A MANNER APPROVED BY LANDSCAPE ARCHITECT. B. ALL TRENCHES SHALL BE A MINIMUM OF 12" FROM SIDEWALKS, C. TRENCHES SHALL BE MADE WIDE ENOUGH TO ALLOW A MINIMUM OF 4" BETWEEN PAMLLEL PIPE LINES. MAINTAIN A MINIMUM OF' l" VERTICAL CLEARANCE BETWEEN LINES, TRENCHES FOR PIPE LINES SHALL BE MADE OF SUFFICIENT DEPTrlS TO PROVIDE THE MINIMUM COVER FROM FINISH GRADE AS FOLLOWS: 1. 18" MINIMUM COVER OVER MAIN LINES TO REMOTE CONTROL VALVES. 2. 12" MINIMUM COVER OVER LATERAL LINES TO HEADS, 3. 24" MINIMUM COVER UNDER DRIVEWAYS, PAVED PARRING AREAS ,i ROADS TO BE 30" . D. MAINTAIN ALL WARNING SIGNS, SHORING, BARRICADES, FLARES, AND RED SIGNAL LANTERNS AS REQUIRED BY THE SAFETY ORDERS OF THE DIVISION OF INDUSTRIAL SAFETY AND ANY LOCAL ORDINANCES. E. SLEEVES: BORE UNDER WALKS AND DRIVES TO A DEPTH CONFORMING TO THE BOTTOM OF ADJACENT TRENCHES. ALL SLEEVES ARE TO BE SCH, 80AND INSTALLED AT A MIN, DEPTH AS DESCRIBED IN B. 3-3.4 OF THE CITY OF CARLSBAD LANDSCAPE MANUEL. SLEEVE SIZES ARE TO BE MIN. 2 PIPE DIAMETER SIZES LARGER THAN THE PIPE CARRYING WATER. CONTROLLER WIRES LOCATED UNDER STREETS OR OTHER PERMANENT IMPROVEMENTS SHALL BE INSTALLED IN THE SEPARATE PVC SLEEVES CORRESPONDING TO TYPE OF DEPTH AS SPECIFIED IN 8. 3-3.4, 8, 3-12.1, /IND B 3-12,2 IN THE CITY LANSCAPE MANUEL. 4.03 PIPE LINE ASSEMBLY A. BACKFLOW PREVENTER: INSTALL 12" MINIMUM ABOVE GRADE WITH CONCRETE THRUST BLOCKS. B. REMOTE CONTROL VALVES: INSTALL WHERE SHOWN. GROUP TOGETHER WHERE PRACTICAL. PLACE NO CLOSER THAN 12" ANO PARALLEL TO SIDEWALK, AND HOUSE IN VALVE BOXES WITH TOPS SET TO GRADE. SNAKE WIRES BESIDE PIPE IN COMMON TRENCH, AT A MINIMUM OF l" FROM PIPE. PROVIDE A 36" LOOP OF WIRE AT EACH VALVE. BUNDLE WIRE AT 10 FOOT INTERVALS WITH A 12" LOOP OF ELECTRI- CIAN'S TAPE, ALLOWING FOR EXPANSION. CONTROL WIRE SPLICES SHALL BE ALLOWED ONLY ON RUNS HORE THAN 500' LONG. CRIMP WIRES TOGETHER WITH STA KON fPT-70 CONNECTOR OR APPROVED EQUAL. SEAL CONNECTION WITH APPROVED SEALING COMPOUND. PROVIDE CONDUIT WHERE WIRES RUN UNDER PAVING, C. PLASTIC PIPE AND FITTINGS: PIPE MAY BE ASSEMBLED AND WELDED ON THE SURFACE. SNAKE PIPE FROM SIDE TO SIDE OF TRENCH BOT- TOM TO ALLOW FOR EXPANSION AND CONTRACTION. SOLVENT-WELD PJ,ASTIC PIPE AND FITTINGS, USING SOLVENTS AND METHODS AS RECOMMENDED BY MANUFACTURER OF THE PIPE, EXCEPT WHERE SCREWED CONNECTIONS ARE REQUIRED. PIPE-AND FITTINGS SHALL BE THOR- OUGHLY CLEANED OF DIRT, DUST, AND MOISTURE BEFORE APPLYING SOLVENT. INSTALL PIPE AT TEMPERATURES OVER 40 DEGREES F. IMPORTANT! CLEAN OFF EXCESS SOLVENT. ALL WELDED JOINTS SHALL CURE AT LEAST 15 MINUTES BEFORE MOVING OR HANDLING, AND AT LEAST 24 HOURS BEFORE WATER IS PERMITTED IN THE PIPE. D. PLASTIC TO METAL PIPE CONNECTIONS: MAKE ALL CONNECTIONS BETWEEN PLASTIC PIPE AND METAL PARTS OR PIPE WITH THREADED FITTINGS USING PLASTIC MALE ADAPTERS. APPLY A NON-HARDEN- ING PIPE DOPE OR TEFLON TAPE TO MALE THREADS, TAKE UP WITH LIGHT WRENCH PRESSURE. E. SPRINKLER HEADS: INSTALL 12" FROM SIDEWALK, DRIVEWAYS, OR CURBS. PLACE TOP OF POP-UP IIEADS FLUSH WITH FINISH GRADE. ALL RISERS SHALL BE OF SCHEDULE 80 PVC PIPE. F. PLUGGING PIPE: CAP OR PLUG ALL OPENINGS AS SOON AS LINES HAVE BEEN INSTALLED TO PREVENT THE ENTRANCE OF MATERIALS THAT COULD OBSTRUCT THE PIPE, AND LEAVE IN PLACE UNTIL REMOVAL IS NECESSARY FOR COMPLETION OF INSTALLATION. G. FLUSHING IRRIGATION SYSTEM: THOROUGHLY FLUSH OUT ALL WATER- LINES, THEN INSTALL HEADS, VALVES, AND OTHER HYDRANTS. TEST IN ACCORDANCE WITH THE FOLLOWING GUIDELINES: 5.02 GU'IAANTEE A. ALL WORK SHALL BE GUARANTEED FOR ONE YEAR FROM DATE OF ACCEPTANCE AGAINST ALL DEFECTS IN MATERIAL. EQUIPMENT, AND WORKMANSHIP. GUARANTEE SHAll. ALSO COVER REPAIR OF DAMAGE TO ANY PART OF THE PREMISES, RESULTING FROM LEAKS OR OTHER DEFECT IN MATERIAL. EQUIPMENT, AND WORKMANSHIP TO THE SATISFACTION OF LANDSCAPE ARCHITECT. B. REPAIRS, IF REQUIRED, SHALL BE' DONE PROMPTLY UPON NOTIFICATION BY LANDSCAPE ARCHITECT AT NO COST TO THE OWNER. . -· ---, __ -AND CITY LANDSCAPE INSPECTOR II. 1. 2. REQUEST THE PRESENCE OF LANDSCAPE ARCHITECT~AT LEAST ',\ FORTY-EIGHT (48) HOURS IN ADVANCE OF TESTING. TEST IS TO BE ACCOMPLISHED AT THE EXPENSE OF CONTRACTOR, AND IN 1 THE PRESENCE OF 'fl!E LANDSCAPE ARCHITECT ,;-IF SO DESIRED, / .. OR WITH SUBMITTAL OF RECORDED RESULTS OF\ TEST. _,,/ . .----· _., ~-"" -- CENTER LOAD PIPING WITH SUFFICIENT AMOUNT OF BACKFILL TO PREVENT ARCHING OR SLIPPING UNDER PRESSURE. APPLY CONTINUOUS WATER PRESSURE OF THE NUMBER OF POUNDS PER SQUARE INCH SPECIF'IED ON THE PLANS AT THE POINT OF CONNECTION. (A) PRESSURE LINES TO BE TESTED FOR FOUR HOURS @ 150 PSI (B) LATERAL LINES TO BE TESTED FOR TWO HOURS @ 95 PSI 3. REPAIR LEAKS RESULTING FROM TESTS /\ND RETEST UNTIL SYSTEM MEETS SPECIFIED TESTS. PRESSURE, 4.04 UPON COMPLETION OF TIIEVTESTING, THE CONTRACTOR SHALL COMPLETE ASSEMBLY AND ADJUST SPRINKLER HEADS FOR PROPER DISTRIBUTION. THE CITY LANDSCAPE CONSULTANT WILL REQUIRE THE CONTRACTOR TO PREFORM A COVERAGE TEST,, AUTOMATIC CONTROLLER A. B. INSTALL CONTROLLER AS SHOWN ON THE PLAN, UNLESS OTHERWISE DIRECTED BY THE L/\NDSCAPE ARCHITECT. CONNECT REMOTE CONTROL VALVES TO CONTROLLER IN A SEQUENCE CORRESPONDING TO VALVE STATION NUMBERS AS SHOWN ON THE PLANS. CONTROLLER CHART: PREPARE A Ml\!' DIAGRAM SHOWING LOCATION OF ALL VALVES, LATERAL LINES, AND ROUTE OF THE CONTROL WIRE. IDENTIFY ALL VALVES AS TO SIZE, STATION, NUMBER, AND TYPE OF PLANTING IRRIGATED, I.E., LAWN, SHRUBS, OR GROUND COVER. SUBMIT DIAGRAM TO LANDSCAPE ARCHITECT FOR APPROVAL, PRIOR TO FINAL INSPECTION. LAMINATE AND MOUNT NEXT TO CONTROLLER. CONTRACTOR TO ALSO FILL OUT CIRCUIT DIAGRAM WITHIN CONTROLLER BOX. 4.05 BACKFILL AND COMPACTING A. AFTER SYSTEM IS OPERATING, AND REQUIRED TESTS AND INSPECTIONS HAVE BEEN MADE, BACKFILL EXCAVATIONS AND TRENCHES WITH CLEAN SOIL, FREE FROM RUBBISH. B. BACKFILL FOR ALL TRENCHES, REGARDLESS OF THE TYPE OF PIPE COVERED, SHALL BE COMPACTED TO 85¼ DENSITY. PART 5 -JOB COMPLETION 5.01 "AS-BUILT" IRRIGATION DRAWINGS LANDSCAPE CONTRACTOR TO A. ')PREPARE AN "AS-BUILT" DRAW! SHOW DEVIATIONS F'llOM THE BI TION AFFECTING THE MAIN LIN VALVES ANO SPRINKLER HEADS. TO LANDSCAPE ARCHITECT BF.FD NG ON A REPRODUCIBLE SEPIA WHICH SHALL D DOCUMENTS MADE DURING CONSTRUC- E PIPE, CONTROLLER LOCATIONS, THE DRAWINGS SHALL BE OF.LIVERED RE FINAL ACCEPTANCE OF WORK. APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. -'. ~ 7 . .,. 11 AS BUIL T 11 TITLE REVIE\JED BY> INSPECTOR CITY OF CARLSBAD PLANNING DEPARTMENT FISH HOUSE VERA CRUZ 6/25/93 DATE DATE 1 sH~:Ts I PLANTING & IRRIGATION SPECIFICATIONS --,-.. APP~S~--" f? !.L /1~ A 7./-73 "✓ ,,,,. ,.• ,, .. ' ,'.' ASSTI_T ANT/PLANNING DIRECTOR DATE ~~--DWN BY: PROJECT NO. DRAWING NO. DATE INITIAL DATE INl11AL DATE INl11AL CHKD BY: ___ ENGINEER OF WORK REVISION DESCRIPTION OHJER APPROVAL CITY APPROVAL RV\JD BY> RP 92-10 332-SL -- PLANTING SPECIFICATIONS PART 1 -GENERAL 1.01 SCOPE OF WORK A. ·woRK DISCUSSED IN THIS SECTION INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, AND EQUIPMENT REQUIRED TO COMPLETE WORK INDICATED ON THE DRAWINGS. THE WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE BEST STANDARDS OF PRACTICE RELATING TO THE VARIOUS TRADES AND UNDER THE CONTINUOUS SUPERVISION OF A COMPETENT FOREMAN, CAPABL!> OF INTERPRETING THE DRAWINGS, NOTES, AND THESE SPECIFICATIONS. B. IRRIGATION AND LANDSCAPE WORK MAY Bl> DON!> CONCURRENTLY, IIOW- !>Vl>R, LANDSCAPl> WORK MAY NOT START IN ANY Sl>CTION PRIOR TO INSPl>CTION AND APPROVAL OF THE SPRINKLER WORK. C. PRIOR TO EXCAVATION FOR PLANTING OR PLACING OF STAKES, LOCATE ALL ELECTRICAL CABL!>S, CONDUITS, SPRINKLl>R VALVES, AND ALL UTILITY LINES SO THAT PROPER PRECAUTIONS MAY BE TAKl>N NOT TO DAMAGE SUCH IMPROVEMENTS. IN THE EVENT OF A CONFLICT BETWEEN SUCH LINES AND PLANT LOCATIONS, PROMPTLY NOTIFY LANDSCAPE ARCHITECT WHO SHALL ARRANGE FOR RELATION FOR ONE OR THE OTHER. FAILURE TO FOLLOW THIS PROCEDURE PLACES UPON THE CONTRACTOR THE RESPONSIBLITY FOR (AT HIS OWN EXPENSE) MAKING ANY AND ALL REPAIRS FOR DAMAGE RESULTING FROM WORK HEREUNDER. 1.02 SUBMITTALS A. CERTIFICATIONS OF CONFORMANCE OR COMPLIANCE: IN ADDITION TO ANY OTHER CERTIFICATES SPECIFIED, THE CONTRACTOR SHALL FURNISH A CERTIFICATE WITH EACH DELIVERY OF BULK MATERIAL STATING THE SOURCE; QUANTITY; TYPE OF MATERIAL, AND THAT THE MATERIAL CONFORMS TO THE SPECIFICATION REQUIREMENT. FOR BULK DELIVERED ORGANIC FERTILIZER, THE CERTIFICATE SHALL ALSO STATE THE VOLUME, NET WEIGHT, PERCENT OF NITROGl>N, PERCENT OF PHOSPHORIC ACID, AND THAT SLUDGE 15 PROPERLY PROCESSED AND WILL NOT BURN OR OTHERWISE DAMAGE PLANTS, OR PLANT ROOTS. FOR OTHER FERTILIZERS AND SOIL CONDITIONERS IN CONTAINERS, A SIMII,AR CERTIFICATE OR INVOICE SHALL BE FURNISHED STATING TOTAL QUANTITIES BY WEIGHTS AND VOLUME FOR EACH MATERIAL. THESE CERTIFICATES SHALL BE SUBMITTED TO THE LANDSCAPE ARCHITECT PRIOR TO THE START OF THE MAINTENANCE PERIOD IF REQUIRED BY OWNER. AFTER THE SOIL HAS BEEN PREPARED AS CALLEO FOR IN THE SECTION ON SOIL PREPARATION, TllE IRRIGATION SYSTEM HAS BEEN INSTALLED AND TESTED, AND CONDITIONS ARE FAVORABLE TO PLANT, THE LANDSCAPE CONTRACTOR SHALL REQUEST APPROVAL TO START PLANTING FROM THE LANDSCAPE ARCHITECT. B. CERTIFIED LABORATORY TEST REPORT$: SUBMIT FOR APPROVAL, CERTIFIED COPIES OF THE REPORTS OF TESTS LISTED BELOW ANO REQUIRED IN REFERENCED PUBLICATIONS FOR THE FOLLOWING MATE- RIALS: 1. AGRICULTURE SUITABILITY SOIL TESTS WILL BE MADE BY THE CONTRACTOR AFTER ROUGH GRADING IS COMPLETED AND CONTRAC- TOR SHALL ADJUST SOIL AMENDMENTS AND CONTRACT SUM ACCORD- INGLY. PART 2 -DELIVERY, STORAGE AND HANDLING 2.01 DELIVERY A. PROVIDE NOTIFICATION OF THE DELIVERY SCHEDULE IN ADVANCE SO MATERIAL MAY BE INSPECTED UPON ARRIVAL AT THE JOB SITE. REMOVE UNACCEPTABLE MATERIAL FROM THE JOB SITE IMMEDIATELY. B. PROTECT PLANTS DURING DELIVERY TO PREVENT DAMAGE TO THE ROOT BALLS OR DESICCATION OF LEAVES. PROTECT TREES DURING TRANS- PORT BY TYING IN THE BRANCHES ANO COVERING ALL EXPOSED BRANCHES. C. DELIVER PESTICIDES AND SOIL FUMIGANTS TO THE SITE IN THE ORI- GINAL UNOPENED CONTAINERS. CONTAINERS THAT DO NOT HAVE A LEGIBLE LABEL THAT IDENTIFIES THE ENVIRONMENTAL PROTECTION AGENCY REGISTRATION NUMBER AND THE MANUFACTUER'S REGISTERED USES WILL BE REJECTED. 2.02 A. B. c. 2.03 A. B. 2.04 A. STORAGE STORE AND PROTECT PLANTS NOT INSTALLED ON THE DAY OF ARRIVAL AT THE SITE AS FOLLOWS: 1. OUTSIDE STORAGE SHALL BE PROTECTED FROM THE WIND, 2. KEEP PLANTS, INCLUDING THOSE IN CONTAINERS, IN A MOIST CONDITION BY WATERING WITH FINE MIST SPRAY, 3. SEPARATE PLANTS TO PREVENT "DAMPING OFF." KEEP GYPSUM AND FERTILIZER IN DRY STORAGE AND AWAY FROM CONTAMINANTS. DO NOT STORE SOIL STERILANT AND HERBICIDES WITH ANY OTHER LANDSCAPE MATERIALS. STORE IN AN APPROVED, LOCKED, SEPARATE STRUCTURE OR VEHICLE. HANDLING PLANTS: TAKE CARE TO AVOID DAMAGING PLANTS BEING MOVED FROM THE NURSERY OR STORAGE AREA TO THE PLANTING SITE. l!ANDLE ALL PLANTS CAREFULLY TO AVOID CRACKING OR BREAKING THE ROOT BALL. DO NOT HANDLE PLANTS BY THE TRUNK OR STEM. REMOVE DAM/\GED PLANTS OR PLANTS WITH BROKEN OR CRACKED ROOT BALLS FROM THE SITE. SPECIMEN PLANTS SHALL BE PLANTED, MULCHED, GUYED, AND IN A BASIN AND FERTILIZED WITHIN 48 HOURS AFTER REMOVAL FROM PRE- VIOUS LOCATION. JOB CONDITIONS PLANTING CONDITIONS: PLANTING SHALL NOT BE DONE WHEN THE GROUND IS MUDDY OR lN AN UNSATISFACTORY CONDITION FOR PLANT- ING. 2. 0 5 A, GUARANTEE WORK SHALL BE SUBJECT TO THE TERMS OF THE CLAUSE ENTITLED "WARRANTY OF CONSTRUCTION" OF THE GENERAL PROVISIONS, EXCEPT THAT PLANT MATERIAL SHALL BE GUARANTEED THROUGH THE PLANT MAINTENANCE PERIOD (SEE 5.03). ALL PLANTINGS SHALL BE GUARANTEED FOR AS LONG AS THE CONTRACTOR IS MAINTAINING THE LI\NDSCAPING, WITH THE EXCEPTIOfl THAT BOXED TREES SHALL BE GUARANTEED FOR ONE YEAR. ANY MATERIAL THAT IS NOT GROWING PROPERLY DURING THIS PERIOD SHALL BE REPLACED BY THE LAND- SCAPE CONTRACTOR WITHIN SEVEN (7) DAYS AFTER THE RECEIPT OF A WRITTEN NOTICE BY THE LANDSCAPE ARCHITECT. ALL PLANT MATERIALS SHALL BE GUARANTl>ED FOR THE ORIGINAL PERIOD, START- ING FROM THE DATE OF REPLACEMEN'r. THE CONTRACTOR'S GUARANTEE MAY BE EXTENDED BY THE LANDSCAPE ARCHITECT IN CASf.S WHERE PJ,ANTS ARE SLOW TO ESTABLISH. IF THE CONTRACTOR FAILS TO MAKE REPLACEMENTS WITHIN THE TIME LIMIT, THE OWNER l'IJW REPLACE THEM AT THE CONTRACTOR'S EXPf,NSE AFTER DULY NOTIFYING HIM. PART 3 -PRODUCTS 3.01 PLANTS A. PLANT MATERIAL SHALL BE FURNISHED IN THE QUANTITIES AND/OR SPACING AS SHOWN, OR NOTED FOR EACH LOCATION, AND SHALL BE OF THE SPECIES, KINDS, SIZES, ETC., AS SYMBOLIZED AND/OR DESCRIBED IN THE "LIST OF PLANT MATERIALS" AS INDICATED ON THE DRAWINGS. PLANT NAMES INDICATED OR LISTED IN THE "LIST OF PLANT MATERIALS" ON THE DRAWINGS CONFORM TO "'STANDARD PLANT NAMES" ESTABLISHED BY THE AMERICAN JOINT COMMITTEE ON HORTICULTURAL NOMENCLATURE, EXCEPT FOR NAMES NOT COVERED HEREIN, Tl!E ESTABLISHED CUSTOM OF THE NURSERY IS FOLLOWED. B. PLANTING STOCK: PLANTING STOCK SHALL BE WELL-BRANCHED AND WELL-FORMED, SOUND, VIGOROUS, HEALTHY, AND FREE FROM DISEASE, SUNSCALE, WINDBURN, ABRJ\SION, ANO HARMFUL INSECTS OR INSf.CT EGGS, AND SHALL HAVE HEALTHY, NORMAL, AND UNBROKEN ROOT SYS- TEMS AND NOT ROOT BOUND. Dl>CIDUOUS TREES ANO SHRUBS SHALL BE SYMMETRICALLY DEVELOPED, OF UNIFORM HABIT OF GROWTH, WITH STRAIGHT BOLES OR STEMS AND FREE FROM OBJECTIONABLE DISFIG- UREMENTS. EVERGREEN TREES AND SHRUBS SHALL HAVE WELL DEVEL- OPED SYMMETRICAL TOPS WITH TYPICAL SPREAD OF BRANCHES FOR F:ACH PARTICULAR SPECIES OR VJ\RIETY. GROUND COVERS AND VINES SHALL .. BE VIGOROUS, HAVE THE NUMBE!f-7illD LllNGTH bF-RUNNERS·; AND CLUMP SIZE SPECIFIED, AND BE THE PROPER AGE FOR THE GRADE OF PLANTS SPECIFIED. ONLY VINES AND GROUND COVER PLANTS WELL ESTABLISHED IN REMOVAB!,E CONTAINERS, INTEGRAL CONTAINERS, OR FORME:D HOMOGENEOUS SOIL SECTIONS SHALL BE USED. PLANTS SHALL NOT BE PRUNED PRIOR TO DELIVERY, EXCEPT AS AUTHOR! ZED BY THE I,ANDSCAPE ARCHITECT, OR HIS REPRESENTA- TIVE. IN NO CASE SHALL TREES Bl> TOPPED BEFORE DELIVERY. C, SIZES OF PLANTS: SHALL BE AS STATED IN THE PLANT LIST. CONTAINER s·rocK (1 GALLON, 5 GALLON, ANO 15 GALLON) SHALL HAVE BEEN GROWN IN CONTAINERS FOR A PERIOD OF TIME SUFFICIENT TO DEVELOP ROOT GROWTH SUFFICIENT TO HOLD THE SOIL BALL TO- GETHER TO THE SIDE AND BOTTOM OF THE CONTAINER IN WHICH IT WAS DELIVERED. THE HEIGHT AND SPREAD OF ALL PLANT MATERIAL SHALL BE MEASURED WITH BRANCHES IN THEIR NORMAL POSITION; AND SHALL BE AS INDICATED ON THE DRAWINGS. THE CALIPER OF ALL TREES SHALL BE MEASURED 2 '-0" ABOVE THE SURF/\CE OF THE GROUND. WHERE CALIPER OR OTHER DIMENSIONS OF ANY PLANT MATERIALS ARE OMITTED FROM THE "LIS'r OF PLANT MATERIALS," IT SHALL BE AVERAGE STOCK FOR TYPE LISTED. D. PLANT MATERIAL: PLANT MATERIAL SHALL BE NURSERY GROWN, UN- LESS OTHERWISE INDICATED. 1. GROUND COVER PLANTS SHALL BE WELL ROOTED CUTTINGS GROWN IN FLATS AND SHALL REMAIN IN THOSE FLATS UNTIL PLANTED. E. SUBSTITUTIONS: FOR THE INDICA~'ED PLANT MATERIALS WILL BE PERMITTED, PROVIDED THE SUBSTITUTE MATERIALS ARE APPROVED F. 3.02 A. B. IN ADVANCE BY THE LANDSCAPE ARCHITECT, AND THE SUBSTITUTIONS ARE MADE AT NO ADDITIONAL CHARGE TO THE OWNER. EXCEPT FOR TIIE VARIATIONS SO AUTHORIZED, l\l .. L SUBSTITUTE PLANT MI\TEJHALS SHALL CON!'ORM TO TllE REQUIREMENTS OF THESE SPECIFICATIONS. IF ACCBPTED SUBSTITUTE MATERIALS ARE OF LESS VALUE THI\N THOSE INDICATED OR SPECIFIED, THE CON'rRACT PRICE WILL BE ADJUSTBD IN ACCORDANCE WITH THE PROVISIONS OF THE CONTRACT. APPROVAL: ALL PLANT MATERIALS SHALL BE SUBJECT TO THE IN- SPECTION AND APPROVAL OF THE LANDSCAPE ARCHITECT, OR BIS REPRESENTATIVE, BEFORE PLANTING. CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF EACH PLANT MATERIAJ, DELIVERY. ALL PLANTS SUPPLIED TO THE PROJECT (WHETHER PLANTED OR NOT) ARE SUBJECT TO REJECTION BY THE LANDSCAPE ARCHITECT. PLANTS NOT APPROVED SHALL BE REMOVED FROM SITE IMMEDIATELY AND REl?LACED WITH SUITAB!,E PLANTS. THE LANDSCAPE ARCHITECT MI\Y REJECT ENTIRE LOT OF PLANTS REPRESENTED BY DEFECTIVE SAMPLES. SEED & SOD SEED FOR LAWNS: AFTER THE IRRIGATION HAS BEEN TESTED FOR COVERAGE, SOIL PREPPED, AND FINISH GRADED, THE LAWN AREAS MAY BE SEEDED, AS CALLED FOR ON THE PLANS. ALL SEEDS SHALL BE BROUGHT TO THE SITE APPROPRIATELY LABELED AS TO SPECIES AND QUANTITIES. ALL SEED SHALL BE APPLIED AT THE RATE CALLEO FOR ON THE PLANS. SEED SHALL BE APPLIED AT AN EVEN RATE BY A MECHANICAL SPREADER AS APPROVED BY THE LANDSCAPE ARCHITECT. SEED FOR HYDROSEEDING: ALL SEED IS TO BE DELIVERED TO THE JOB SITE, UNMIXED, IN SEPARATE SEALED CONTAINl>RS. EACH SEALED CONTAINER Wil,L BEI\R THE SEED SUPPLIERS' TAGS WHICH SHALL INDICATE THE CONTAINER WEIGHT, SEED TYPE, AND SEED PURITY, AND SEED GERMINI\TION. AT,L SEED SHALL BE LABELED ACCORDING TO STATE AND FEDERAL SEED LAWS. A SAMPLE OF EACH SEED TYPE WILL BE DRAWN BEFORE SEF.DING TO ASSURE THAT SEED SPECIFICATIONS HAVE BEEN MET. PLANT NAMES INDICATED OR LISTED IN THE "LIST OF PLANT MATERIALS" ON THE DRAWINGS MUST CONFORM TO "STANDARD PLANT NAMES" ESTABLISl!ED BY THE AMERICAN JOINT COMMITTEE ON HORITCULTURAL NOMENCLATURE. WHEN NAMES ARE NOT COVERED THEREIN, THE ESTABLISHED CUSTOM OF THE NURS.ERY IS FOLLOWED. 1. PLANT LIST1 AS INDICATED ON DRAWINGS. 2. SI\MPLES, TESTS, AND INSPECTIONS: SOURCE OF MATERIAL SHALL BE FURNISHED IF REQUESTED BY THE OWNER OR LANDSCAPE ARCHI- TECT. 3. MULCH FOR HYDROSEEDING: EACH PACKAGE OF CELLULOSE SHALL SHOW AIR-DRY WEIGHT. FIBER WEIGHT SHALL BE EQUIVALENT TO TEN PERCENT MOISTURE AS BASED ON THE TECHNICAL ASSOCI- ATION OF PULP AND PAPER INDUSTRY STANDARDS FOR AIR-DRY CELLULOSE. 4. SLURRY FOR HYDROSEEDING: NO GROWTH INHIBITING MATERIAL SHALL BE PERMITTED IN THE HYDROSEED SLURRY. 3.09 A. B. 1. LOAMEX IS A BLEND OF ORGANIC FRACTION TO SUPPLY SEVERAL BREAKDOWN RATES AND A PORTION OF INORGANIC AMENDMENTS THAT RESIST FURTHER BREAKDOWN. 2. THE MIX SHALL ALSO CONTAIN A LONG LASTING FORM OF IRON (G.U.49) AND A NON-IONIC WETTING AGENT, AVAILABLE FROM BUTLER'S MILL, INC., LOCATED IN SAN DIEGO. TREE STAKING AND GUYING MATERIAL STAKES: SHALL BE 10' LODGEPOLE STAKES POINTED ON ONE END. TREE TIES: SHALL BE CINCH TIE OR APPROVED EQUAL. C. SOD FOR LAWNS: SOD SHALL BE AS INDICATED ON THE PLANS. THE SOURCE OF THE SOD SHALL BE SUBJECT TO APPROVAL OF THE LANDSCAPE ARCHITECT. '!.'HE LANDSCAPE CONTRACTOR SHALL TAKE PRECAUTIONS c. ANCHORS: SHALL BE DUCKBILL (TM) PRODUCT OF APPROPRIATE SIZE AS RECOMMENDED BY MANUFACTURER (FORESIGHT INDUSTRIES, INC., P.O. BOX 4067, CHEYENNE, WY 82003). 3.03 A. ,3. 04 3.05 A. B. C. D. E. ].06 A. B. C. 3.07 3.C18 IN THE HANDLING AND TEMPORARY STORAGE OF THE SOD. TOPSOIL WHERE NEW TOPSOIL IS CALLED FOR, PROVIDE NEW TOPSOIL AND/OR MODIFY EXISTING TOPSOIL TO SUPPLY THE FOLLOWING COMPOSITIONS REQUIREMENTS: PH BETWEEN 6 AND 7.6, CONTAINING FROM 5 TO 20 PERCENT ORGANIC MATTER AS DETERMINED BY THE ORGANIC CARBON 6A, CHEMICAL ANALYSIS METl!OD DESCRIBED IN USDA SOIL SURVEY INVESTIGATION REPORT NO. 1. MAXIMUM PARTICLE SIZE. 3/4-INCH. WITH MAXIMUM 3 PERCENT RETAINED ON 1/4-INCH SCREEN. SOLUBLE SALTS SHALL NOT EXCEED 600 PPM. OTHER COMPONENTS SHALL BE WITHIN THE FOLLOWING PERCENTAGES: PH ADJUSTERS: SILT CLAY SAND 25-50 10-30 20-35 1. GYPSUM: COMMERCIALLY PACKAGED, FREE FLOWING GYPSUM CON- TAINING NOT LESS THAN 95 PERCENT, BY VOLUME, OF CALCIUM SULPHATE AS ACTIVE INGREDIENT. SOIL CONDITIONERS USE INDIVIDUALLY OR IN COMBINATION AS REQUIRED TO MEET SPECI- FIED REQUIREMENTS FOR TOPSOIL. PEAT: SPHAGNUM MOSS PEAT, HYPNUM MOSS PEAT, REED-SEDGE PEAT, AND PEAT HUMUS, EXCEPT AS OTHERWISE SPECIFIED HEREIN. PEAT SHALL BP, DI.CRlVED FROM A FRESHWATER S I1'E, SHREDDED AND GRANU- LATED TO PASS A ~-INCH MESH SCREEN AND CONDITIONED IN STORAGE PILES FOR AT LEAST SIX MONTHS PRIOR TO USE. MANURE: COMMERCIALLY STERILIZED AND SACKED STEER MANURE CONTAINING MAXIMUM 25 PERCENT BY VOLUME OF STRAW, SAWDUST, OTHER BEDDING MATERIALS FREE OF STONES, STICKS, SOIL, AND TOXIC MATERIALS HARMFUL TO PLANTS; WELL COMPOSTED AND SCREENED •ro PASS THROUGH A 1/4-INCH SIEVE. NITROLIZED WOOD DERIVATIVES: GROUND BARK, SAWDUST, OR OTHER WOOD WASTE MATERIAL FREE OF STONES, STICKS, AND TOXIC SUBSTANCES HARMFUL TO PLANTS, STABILIZED WITH NITROGEN AND HAVING THE FOLLOWING PROPERTIES: PARTICLE SIZE: MINIMUM PERCENT BY WEIGHT PASSING: NO. 4 MESH SCREEN 95 NO. 8 MESH SCREEN BO NITROGEN CONTENT: MINIMUM PERCENT BASED ON DRY WEIGHl': REDWOOD SAWDUST 0.5 FIR SAWDUST O. 7 FIR OR PINE BARK l.O COMPOSTED ORGANIC WASTE: CHEMICALLY TREATED AND COMPOSTED ORGANIC WASTES SUCH AS RICE HULLS, SPENT COFFEE BEANS, SLUDGE, PEAT AND WOOD WASTES. FERTILIZER AND SOIL CONDITIONER: ORGANIC MATERIALS (EXCLUD- ING HUMAN WASTES) CONTAINING TIIE FOLLOWING MINIMUM PERCENTAGES, BY WEIGHT, BY PLANT FOOD NUTRIENTS, AND HUMUS. FERTILIZER 5% NITROGEN 3% PHOSPHATE 1% POTASH 50% HUMUS 15% HUMIC ACIDS FERTILIZER: COMPLETE COMMERCIAL, GRANULAR FERTILIZER CON- TAINING THE FOLLOWING MINIMUM PERCENTAGES, BY WEIGHT, OF PLANT FOOD NUTRIENT$: 18\ AVArLllBLE NITROGEN 18% AVAILABLE PHOSPHOROUS 6\ AVAILABLE POTASSIUM 1.8\ SULFUR 1. 5% IRON FERTILIZER PLANTING TABLETS: TIGHTLY COMPRESSED FERTILIZER CHIPS FORMING A TABLET THAT IS INSOLUBLE IN WATER, IS DESIGNED TO PROVIDE A CONTINUOUS RELEI\SE OF NUTRIENTS FOR AT LEAST 24 MONTHS AND CONTAINS THE FOLLOWING MINIMUM PERCENTAGES, BY WEIGHT, OF PLANT FOOD NUTRIENTS: 20% AVAILABLE NITROGEN 10% AVAILABLE PHOSPHORUS 5\ AVAILABLE POTASSIUM PLANTING TABLETS SHALL WEIGH APPROXIMATELY 21 GRAMS EACH FOR TREES AND SHRUBS AND 5 GRAMS EACH FOR GROUND COVER PLANTS. IRON CHELATE$: CONTAINING 10 PERCENT IRON AS METALLIC, MULCH D. GUYING WIRE: SHALL BE 19 ZINC-COATED WIRE. E. HOSE CHAFING GUARDS: SHALL BE 2-PLY REINFORCED RUBBER OR PLI\STIC l!OSE, ~" or 3/4" fJ, TO COVER WIRE AT ALL POINTS OF CONTACT WITH TREE. F, TURNBUCKLES: AS REQUIRED, GALVANIZED 3" MINIMUM LENGTHWISE DIMENSION. 3.10 PESTICIDES AND CHEMICAL CONTROLS SHALL BE USED IN THEIR APPROPRIATE APPLICATIONS WITH STRICT ADHERENCE TO MANUFACTURERS SPECIFICATIONS & INSTRUCTIONS, A. BROADLE/\F WEED CONTROL SHALL BE WEED B. GONE, OR OTHER 2-4-D BASED PRODUCTS. B. PRE-EMERGENCE APPLICATIONS: EPTAM, TREFLAN, SURFLAN OR RONSTAR. C. POST-EMERGENCE APPLICATION: ROUNDUP. D. INSECT CONTROL SHALL BE SPECTRACIDE, MALATHION-SO, DIAZINON OR AS DEEMED APPROPRIATE BY THE LANDSCAPE ARCHITECT. E, FUNGUS CONTROL SHALL Bl> DACONIL OR BORDOIL. F. ALTERNATIVE PRODUCTS MAY BE USED IF APPROVED IN WRITING BY THE LANDSCAPE ARCHITECT. J.11 PLANTING SOIL MIXTURE MIXTURE SHALL BE THOROUGHLY MIXED TO THE PROPORTIONS GIVEN ON THE PLANS • PART 4 -EXECUTION 4.01 PREPARATION OF PLANTING BEDS A. AFTER ALL TRENCHES IN PLANTING AREAS HAVE BEEN SOAKED AND COMPACTED, AND ALL AREAS WITH SLOPES OF LESS THAN 4:1 HAVE BEEN ROUGH GRADED, THESE AREAS SHALL BE CROSS-RIPPED OR TILLED & AMENDED, PER PI,ANS, TO A DEPTH OF 6"". REMOVE STONES & DEBRIS LARGER THAN 2)i INCHES IN DIAMETER. B. TURF AREAS: ALL AREAS TO BE PLANTED WITH TURF SHALL BE THROUGHLY TILLED & AMENDED, PER PLANS, TO MINIMUM DEPTH OF 6 INCHES BY SCARIFYING, DISKING, HARROWING, OR OTHER APPROVED METHODS:--REMOVE PERRIS AND ·sToNEs LARGEii'-rliiitt-6NE INCH IN ANY DIMENSION REMAINING ON SURFACE AFTER TILLAGE. ADD AND TILL IN ALL SOIL AMENDMENTS, AS CALLED FOR IN PLANS, TD A DEPTH OF 6'" • C. SLOPES: THE LANDSCAPE CONTRACTOR WILL RECEIVE ALL SLOPES AT FINISH GRADE. ALL SLOPES SHALL BE INSPECTED BY THE LANDSCAPE ARCHITECT PRIOR TO HYDROSEEDING TO INSURE THAT D, 4.02 A. THEY ARE FREE OF EROSION, GULLIES, WEEDS, OR OTHER DELETERIOUS MATERIALS TO PROVIDE A SEED BED TYPICAL TO GRADED SLOPES IN THAT REGION. SLOPES SHALL NOT BE DISTURBED IN A MANNER WHICH CHANGES THE SOIL COMPACTION ESTABLISHED BY THE SOIL ENGINEERS. IN PARTICULAR, SLOPES SHALL NOT BE MADE MORE PERMEABLE TO WATER, THUS CREATING AN UNSTABLE SURFACE AREA. SOIL TREATMENT: APPLY THE FOLLOWING SOIL TRl>ATMENTS TO THE AREAS LISTED BELOW FOR EACH TREATMENT. FOR APPLICATION, SEE PARAGRAPH "APPLICATION OF PESTICIDES'' IN THIS SPECIFICATION. 1. SELl>CTIVE-COMBINAl'ION WEED CONTROL: 6 WEEKS RESIDUAL (MAXIMUM) . PRE-EMERGl>NCE CONTROL -ALL PLANTED AREAS, EXCEPT SEEDED AREI\S, TWICE, ONCE 14 DAYS MINIMUM AFTER GROUND COVER rs PLANTED, AND ONCE AT END OF MAINTENANCE PERIOD. 2. POST-EMERGENCE CONTROL -ALL PLANTED AREAS -AT ALL TIMES AS REQUIRED. 3. PEST AND DISEASE CONTROL -AT ALL TIMES AS REQUIRED. FINAL GRADING AFTER COMPLETION OF ALL SOIL CONDITIONING, TILLING AND SOIL TREATING, CORRECT IRREGULARITIES IN FINISHED SURFACES TO ELIMINATE DEPRESSIONS. REMOVE /\LL DEBRIS AND STONES LARGER THAN ONE INCH REMAINING ON Tl!E SURFACE. PROTECT FINISHED AREAS FROM DAMI\GE DUE TO VEHICULAR OR PEDESTRIAN TRAFFIC. 6/2 i/93 ,----------------------------------....;;;.,;_;;;;...,:..=;;.., APPROVED f7 OR PLANTING AND IRRIGATION ONIJY, INCl,Ul)lNG PRECISE LOCATION OF PLAN'l'ING AREAS. 11 AS BUIL T'1 TITLE ________ _ REVIE\,/ED BY, INSPECTOR DAT~ i SHALL BE 3" LAYER OF GROUND AND SHREDDED FIR BARK LIGHTWEIGHT SOIL FOR PLANTERS A SOIL MIXTURE OF THE FOLLOWING COMPOSITION SHALL BE USED 1-------+--!~----------+-------+---l---l----l ~ ;::==~=========:::'...:::===~ CITY OF CARLSBAD PLANNING DEPARTMENT SHIEETS ![} FOR IMPORT SOIL TO FJ:LL RAISED PLANTERS /\NO POTS. SOIL SHALL BE PREMIXED BY MACHINE BLENDER PRIOR TO DELIVERY TO SITE, 9 PARTS BY VOLUME -LOAMEX OR EQUAL l PART BY VOLUME WASHED PLASTER SAND 2 CU. FT. PER CU. YD. OF MIX PERLITE 10 POUNDS PER CU. YD. OF MIX MICRO-MAX. PLUS OR EQUAL (MICRO-NUTRIENT COMPLEX) 10 POUNDS PER CU. YD. OF MIX 18-6-8 FERTILIZER ·----;---t--------------,---------+---+---+----+-----t DATE INITIAL DATE INITIAL ·---~-----< ENGINE£R OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL FISH HOUSE VERA CRUZ i PLANTING & IRRIGATION SPECIFICAT10Js APPROVED./4.:_ , /[J ()_, .. tJ ASSIST~T Pl...1-NNING DIRECTOR -' OWN BY: . CHKD BY: __ _ RV\JD BY• PROJECT NO. RP 92-10 DRAWINI~ NO. 332-8L PLANTING SPECIFICATIONS, CONTINUED B, DEEP WATERING AND LEACHING: AFTER SOIL CONDITIONING AND FINAL GRADING IS COMPLETE, COMPACT AND LEACH PLANTING AREAS BY HEAVY WATERING TO A MINIMUM DEPTH OF 12 INCHES. 4.03 SEEDING & SODDING A, WEED CONTROL: PRIOR TO ANY SEEDING, IRRIGATE ALL PLANTING AREAS FOR APPROXIMATELY TWO (2) WEEKS TO ENCOURAGE WEED SEED GERMINATION, ALLOW WEEDS TO GROW UNTIL THEY REACH A MAXIMUM HEIGHT OF TWO TO THREE [2 TO 3) INCHES AND THEN THOROUGHLY SPRAY WITH THE FOLLOWING CONTACT HERBICIDES: 1. FOR PERENNIAL WEEDS SUCH AS MORNING GLORY AND BERMUDA, SPRAY WITH "ROUND UP." 2. FOR ANNUAL WEEDS AND GRASSES, SPRAY WITH PHYTAR 560 OR "WEED BOOMER," IN WET SOILS, SPRAY WITH "WEED OIL." 3. REMOVE ALL WEEDS PRIOR TO SEEDING. DO NOT ALLOW THE USAGE OF ANY PRE-EMERGENCE HERBICIDES OR "DOWPON" FOR WEED CONTROL. B. BROADCAST LAWN SEEDING: ALL SEED NOT DRILLED INTO THE SOIL MUST BE MULCHED WITH ONE-HALF (~) CUBIC YARD OF FINELY SCREENED MULCH OR TOP DRESSING PER 1,000 SQUARE FEET AFTER SEEDING. D. 4.04 A. THE SEED SHALL BE KEPT MOIST AT ALL TIMES THROUGH FREQUENT LIGHT WATERINGS. TUE SEED SHALL NOT BE WATERED TO THE POINT OF PUDDLING. AS THE ROOTS REACH DEEPER INTO THE SOIL, THE TIME BETWEEN WATERINGS SHALL BE EXTENDED. AREAS SHALL BE PROTECTED FROM TRAFFIC UNTIL AFTER THE FIRST MOWING. NEW LAWNS SHALL NOT BE MOWED SHORTER THAN 2\j INCHES. GRASS SHALL BE CUT WITH A SHARP REEL TYPE MOWER, 2. 3. 4. SUPERVISION: ALL HYOROSEEDlNG IS SUBJECT TO APPROVA E LANDSCAPE ARCHITECT OR HIS REPRESENTATIVE, AND IF NECESSARY, BE RELOCATED AS DIRECTED AS CONTRACT, THE LANDSCAPE ARCHITECT OR HI VE SHALL SUPERVISE THE HYDROSEEDING. PPLICATION: A SLURRY OF FERTIL AND WOOD OR FIBER SHALL BE AGITATED R, SEED, PROVIDE A UNIFORM MIX, D SHALL BE HYDRAULICALL . RAYED ON THE THE MATERIAL '"EED AND SHALL ALLOW ION OF MOISTURE INTO ·' WHICH HAS NOT BEEN SHALL BE REJECTED. SOIL TO PROVI OMPLETE, EVEN COVE SHOULD BE UNIFO IMPREGNATED WIT PENETRATION OF RA LL AND PERCO THE UNDERLYING SOIL. LURRY MI APPLIED WITHIN 8 HOUR MIX PREPLANTING FERTILIZEROMli OR CHIP TYPE, UNIFORM I COMR SUITABLE FOR APPLICAT WITH BE AN ORGANIC, PELLETED ITION, FREE-FLOWING, ROVED EQUIPMENT, AND ORIGINAL CONTAINERS, MENT OF GUARANTEED DELIVERED TO THE SIT UNOPEN · EACH BEARING FACTURER'S S ANALYSIS AND SHA CONTAIN FERTILIZ· AS RECOMMENDED BY AGRICULTURA ITABILITY SOIL TEST TILIZER MAY -PPLIED WITH THE HYDROSE GUARANTEE CONTRAC ( 3 0) ALL HYDROSEEDING SHALL BE GUARA AS TO GROWTH AND HEALTH FOR A PERIO AFTER FINAL ACCEPTANCE BY THE LANDSCAP FER- l'EC D AREAS THAT FAIL TO GROW SHALL BE RESEEDED U TION OF THE LANDSCAPE ARCHITECT. THE CONTRACTO JECT TO THIRTY (30) DAY MAINTENANCE OF THE RESEEDED J\S. ING: SODDING SHALL BE DONE IN ACCORDANCE EClFICATIONS FOR SODDING. SOD SHALL BEL THE TIME IT WAS CUT AT THE SOD THAT !!AS DRIED OUT OR BEEN D WIT!! ALTERNAT. TS IN A MANNER THAT AN .. EVEN-, SMOOTH SURFACE ON A PRE SOD BED THAT R EXCESSIVELY ORY NOR WET. LON D so !ALL BE AT RIGHT ANGLES TO SLOPES OR FLOW UNDS OR SLOPED AREAS, SOD SHALL BE LAID START! • AFTER BEING LAID, SOD SHALL BE ROLLED N ALM , ROLLER DRUM, AND LIGHTLY TOP-DRESSED lE SEAMS, D, TO PRODUCE A SMOOTH FINISH. EDIATELY AFTER RO, SHALL BE WATERED AT A SUFFICIENT TO INSURE THO ING OF THE SOIL DEPTH OF AT LEAST FOUR INCHES. HAS RACTOR SHALL TAKE CARE TO CUT BACK ON ERING T THE GROWTH OF FUNGUS. SOD THAT FAILS TO ANO HEALTHY SHALL BE REPLACED BY THE LANDSCAPE CON 111S OWN EXPENSE. PLANTING TREES, SHRUBS, GROUND COVERS, ANO VINES EXCAVATION FOR PLANTING: PRIOR TO EXCAVATING FOR PLANT PITS, THE AREA SHALL CONFORM TO THE LINES AND GRADES SHOWN. VERIFY LOCATION OF UNDERGROUND UTILITIES, REPAIR ANY DAMAGE DONE TO UTILITY LINES SHOWN. IF UTILITY LINES NOT SHOWN ON THE DRAW- INGS ARE ENCOUNTERED, NOTIFY THE CONTRACTING OFFICER IMMEDI- ATELY. IN THE EVENT THAT UNDERGROUND CONSTRUCTION WORK OR OBSTRUCTIONS ARE ENCOUNTERED IN THE PLANTING OPERATION, ALTERNATE LOCATIONS WILL BE DONE AT NO EXTRA COST TO THE OWNER, 1. PLANT PITS: DIG PITS BY ANY METHOD PROVIDED THAT THE 2. PITS HAVE VERTICAL SIDES ANO FLAT BOTTOMS. WHEN P!TS ARE DUG WITH AN AUGER AND THE SIDES OF THE PITS BECOME. GLAZED, SCARIFY THE GLAZED SURFACE. THE MINIMUM ALLOW- ABLE DIMENSIONS OF PLANT PITS SHl,LL BE AS SHOWN IN DETA!LS. IF THE PERCOLATION IS SUCH THAT WATER WILL NOT DRAIN OUT OF THE HOLE OVERNIGHT, THE CONTRACTOR SHALL TAKE CAUTION NOT TO OVERWATER PLANTS. NO TREES 15 GALLONS AND OVER SHALL BE PLANTED IN A HOLE THAT WILL NOT NA~'URALLY DRAIN OVERNIGHT AFTER HAVING BEEN HALF-FILLED WI~'H WATER. TESTS SHALL BE CONDUCTED TO MAKE THIS DETERMINATION AND THE LANDSCAPE ARCHITECT NOTIFIED OF THIS CONDITION PRIOR TO PLANTING. SUBSOIL DRAINAGE FOR PLANT PITS AND BEDS: PROVIDE AS INDICATED, LAY PERFORATED DRAIN PIPE WITH PERFORATIONS DOWN. B. ALL PLANTS SHALL BE SET SO THAT, WHEN SE1'TLED, THEY BEAR THE SAME RELATION TO THE REQUIRED GRADE AS THEY BORE TO THE NATURAL GRADE BEFORE BEING TRANSPLANTED, EACH PLANT SHALL BE PLANTED IN THE CENTER OF THE PIT AND BACKFILLED, UNLESS OTHERWISE SPECIFIED, WITH THE PREPARED SOIL. NO SOIL WILL BE PERMITTED AROUND TRUNKS OR STEMS. ALL BROKEN OR FRAYED ROOTS SHALL BE PROPERLY CUT OFF. USE EXCESS TOPSOIL TO FORM WATERING BASINf AROUND PLANTS. AMEND AS DESCRIBED IN NOTES AND DETAILS. 1. WATER THOROUGHLY WITH A SOLUTION OF VITAMIN B-1 AND WATER PER MANUFACTURER'S SPECIFICATIONS, 2. GROUND COVERS AND VINES: DO NOT REMOVE FROM FLATS AND CONTAINERS UNTIL IMMEDIATELY BEFORE PLANTING. SPACE AT THE INTERVALS INDICATED, SUFFICIENTLY DEEP TO COVER ALL ROOTS. AFTER PLANTING 100 PLANTS, IMMEDIATELY SPRINKLE WITH A SOLUTION OF VITAMIN B-1 AND WATER, PER MANUFAC- TURER'S SPECIFICATIONS, UNTIL ENTIRE AREA IS SOAKED. SMOOTH PLANTING AREAS AFTER PLANTING TO PROVIDE EVEN, SMOOTH FINISH. C. STAKING AND GUYING: 5-GAL THRU 24" BOX 1. STAKING: STAKE ALL V TREES WITH TWO STAKES, DO NOT INJURE THE BALL OR ROOTS. 2. GUYING: GUY BOXED TREES WITH 3 GUYS EVENLY SPACED AROUND EACH TREE AS SHOWN IN DETAILS. D. MULCH!NG: WHEN PLANTING OPERATIONS ARE COMPLETE AND SHRUB AREAS HAVE BEEN RAKED AND DRESSED, MULCH ALL SHRUBS AND GROUND COVER AREA WITH A 3" LAYER OF GROUND FIR BARK, NOTE: MULCH FLATTENED GROUND COVER AREAS PRIOR TO PLANTING GROUND COVER. E. APPLICATION OF PESTICIDES (INC. HERBICIDES & FUNG!CIDES): APPLY ALL HERBICIDES AND OTHER CHEMICALS IN ACCORDANCE WITH EPA LABEL RESTRICTIONS AND RECOMMENDATIONS AND FEDERAL AND STATE LAWS. MAKE DAILY REPORTS TO THE CONTRACTING OFFICER STATING AREAS TO BE TREATED WITH EACH CHEMICAL, THE QUANTITY APPLIED AND SPRAY MIXTURE OF FORMULATION USED. APPLICATION AT EACH SITE SHALL BE UNDER THE SUPERVISION OF A CERTIFIED APPLICATOR. LICENSED BY THE STATE OF CALIFORNIA. , PART 5 -COMPLETION OF CONTRACT 5,01 RESTORATION AND CLEAN-UP A. REMOVE EXCESS WASTE MATERIAL DAILY. WHEN PLANTING IN AN AREA IS COMPLETE, CLEAR THE AREA OF DEBRIS, SPOIL PILES, AND CON- TAINERS. WHERE EXISTING TURF AREAS OR PLANTING BEDS HAVE BEEN SCARRED OR DAMAGED, RESTORE THESE DAMAGED AREAS TO THEIR ORIGINAL CONDITION. KEEP AT LEAST ONE PAVED PEDESTRIAN ROUTE TO EACH BUILDING CLEAN AT ALL TIMES. REMOVE DISUSF.D EQUIPMENT AND IMPLEMENTS OF SERVICE AND LEAVE ENTIRE AREA INVOLVED IN A NEAT ACCEPTABLE CONDITION SUCH AS •ro MEET THE APPROVAL OF THE LANDSCAPE ARCHITECT. 5.02 INSPECTIONS A. THE LANDSCAPE ARCHITECT SHALL MAKE PERIODIC INSPECTIONS DURING THE PLANTING. ANY PLANTS THAT HAVE NOT BEEN HANDLED, SPOTTED OR PLANTED PROPERLY SHALL BE SUBJECT TO REMOVAL BY THE LANDSCAPE ARCHITECT OR HIS REPRESENTATIVE, AND THEY SHALL, IF NECESSARY, BE RELOCATED AS DIRECTED AS PART OF THE CONTRACT. 5.03 MAINTENANCE PERIOD A. DEFINITION: THE MAINTENANCE PERIOD $HALL BEGIN ON THE DATE THAT THE OWNER OR DULY APPOINTED REPRESENTATIVE INSPECTS AND GIVES WRITTEN PROVISIONAL ACCEPTANCE OF THE WORK AND SHALL CONTINUE FOR 30 DAYS FROM TIIAT DATE. THE DATE FOR ACCEPTANCE OF BOXED TREES SHALL BE SET AT 12 MONTHS FROM THAT DATE, B. MAINTENANCE: MAINTAIN ALL PLANTING AREAS IN A VIGOROUS, THRIV- ING CONDITION BY WATERING, CULTIVATING, SPRAYING, WASHING OFF WALKS, AND ANY OTHER NECESSARY OPERATIONS DURING THE ENTIRE PERIOD OF THE INSTALLATION AND UNTIL FINAL ACCEPTANCE BY THE LANDSCAPE ARCHITECT. C. CONTRACTOR SHALL CONTINUOUSLY MAINTAIN ALL AREAS INCLUDED IN THE CONTRACT PURI NG THE PROGRESS OF THE WORK, 'l flROUGII THE ESTABLISHMENT PERIOD, AND UNTIL FINAL ACCEPTANCE OF TflE WORK. D. THE ENTIRE PROJECT SHALL BE SATISFACTORILY MAINTAINED FOR A PERIOD OF THIRTY CALENDAR DAYS, COMMENCING FROM THE TIME ALL ITEMS OF IRRIGATION AND LANDSCAPE PLANTING WORK HAVE BEEN COM- PLETED AS SPECIFIED 'IN THE FOREGOING ARTICLES OF THESE SPECIAL PROVISIONS AND TO THE SATISFACTION OF THE OWNER. E. ESTABLISHMENT WORK INCLUDES ALL MOWING, WATERING, WEEDING, RESEEDING, MULCHING, CULTIVATING, SPRAYING, AND TRIMMING NEC- ESSARY TO BRING THE PLANTED AREAS TO A HEALTHY GROWING CONDI- TION, AND ANY ADDITIONAL WORK NEEDED TO KEEP THE AREAS NEAT, EDGED, AND ATTRJ\CTIVE. F. G. H, WATER GRASS UNTIL ACCEPTANCE OF WORK. THE AREAS SHALL BE KEPT MOIST, BUT NOT GLISTENING WET, UNTIL TIME FOR THE FIRST CUTTING OF GRASS. AFTER FIRST CUTTING, WATER LAWN TO MAINTAIN A THRIVING CONDITION, RESEEDED AREAS THAT DO NOT SHOW PROMPT GERMINATION SHALL BE AGAIN RESEEDED AT TEN DAY INTERVALS. THE CONTRACTOR SHALL MAINTAIN THE LAWN AREAS UNTIL AN EVEN, CLOSE STAND OF GRASS HAS BEEN OBTAINED AND FOR AT LEAST THIRTY DAYS, DURING THE PLANT ESTABLISHMENT PERIOD, ALL PLANTS AND PLANTED AREAS SHALL BE KEPT WELL WEED-FREE AT ALL TIMES. WEEDS, DALLAS AND JOHNSON GRASS, AND BERMUDA GRASS SHALL BE REMOVED AND DISPOSED OF. PAY SPECIAL ATTENTION TO WATERING SLOPES PLANTED IN LAWN ON THE WINDWARD AND/OR SUNNY SIDE SO THAT LAWN WILL BE ADEQUATELY WATERED AT ALL TIMES. THE LAWNS SHOULD BE EDGED WHENEVER NECESSARY. THE GRASS SHALL BE MOWED WITH SHARP AND ADJUSTED MOWERS BEFORE IT EXCEEDS 2" IN HEIGHT. THE GRASS WILL BE CUT TO NOT LESS THAN 11:i", AND K, ANY DAY THE CONTRACTOR FAILS TO ADEQUATELY WATER, REPLACE UNSUITABLE PLANTS, WEED, AND OTHER WORK DETERMINED TO BE NECESSARY BY THE ARCHITECT, WILL NOT BE CREDITED AS PART OF THE ESTABLISHMENT PERIOD. L. DURING THE ESTABLISHMENT PERIOD, ANY PLANT INDICATING WEAKNESS OR PROBABILITY OF DYING, SHALL BE REPLACED BY THE CONTRACTOR AT HIS OWN EXPENSE. M. ALL BASINS AROUND SHRUBS AND TREES SHALL BE MAINTAINED AT A FOUR INCH DEPTH THROUGHOUT ESTABLISHMENT PERIOD, UNLESS OTHERWISE INSTRUCTED BY THE OWNER OR HIS REPRESENTATIVE. N. TREE STAKES WHICH FOR ANY REASON ARE DAMAGED OR RENDERED INADEQUATE FOR SUPPORT SHALL BE REPAIRED AND RESTORED TO THEIR ORIGINAL CONDITION, O. CONSTANT DILIGENCE SHALL BE MAINTAINED TO DETECT THE PRESENCE OF DISEASE, INSECTS, AND/OR RODENT INFESTATIONS AND PROPER PREVENTATIVE OR CONTROL MEASURES TAKEN. P. ALL SHRUBS AND TREES SHALL BE MAINTAINED IN THEIR NATURAL SHAPES. TALL OR SCRAGGLY BRANCHES SHALL BE THINNED OUT WHERE NECESSARY. IN NO CASE SHALL TREES OR SHRUBS BE TRIMMED BY HEADING OR SHEARING, ANY PLANTS SEVERELY PRUNED IN THIS MANNER SHALL BE REMOVED AND REPLACED AT CONTRACTOR'S EXPENSE. Q, ON THE 30TH DAY OF THE ESTABLISHMENT PERIOD, ALL LAWN AREAS SHALL RECEIVE TOP DRESSING OF 10 POUNDS OF 16-8-8 COMMERCIAL FERTILIZER PER 1,000 SQ. FT, R. ON THE BOTH DAY OF THE ESTABLISHMENT PERIOD, ALL LAWN AND GROUND COVER AREAS SHALL RECEIVE TOP DRESSING OF 10 POUNDS OFU-8-8 COMMERCIAL FERTILIZER PER 1,000 SQ, FT, s. T. u. AT COMPLETION OF ESTABLISHMENT PERIOD, ALL AREAS INCLUDED IN THE CONTRACT SHALL BE SUBSTANTIALLY CLEAN AND FREE OF DEBRIS AND SEEDS, ALL PLANT MATERIALS SHALL BE LIVE, HEALTHY, AND FREE OF INFESTATIONS. ANY EROSION OR SLIPPAGE OF SOIL CAUSED BY WATERING SHALL BE REPAIRED BY THE CONTRACTOR AT HIS EXPENSE. ALL WALKS, CURBS, AND GUTTERS SHALL BE KEPT CLEAR OF DEBRIS, MUD, DUST, AND STANDING WATER BY SWEEPING, MOPPING, OR HOSING DOWN AS REQUIRED TO MAINTAIN CLEANLINESS THROUGHOUT. END OF SECTION APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCA1'ION OF PLAN1'ING AREAS. /I AS BUil T11 TITLE ________ _ REVIE\.IED BY• INSPECTOR 6/2 /93 DAT~ i DAT ~ CITY OF CARLSBAD SHtETS ---t-------t-------------_.:.-l---+--l---+---1 L!::!!j PLANNING DEPARTMENT ~~ ~==-===================-==::::: DA TE INITIAL ENGfNE(R Of' WORK REVISION DESCRIPTION FISH HOUSE VERA CRUZ , PLANTING & IRRIGATION SPECIFICATION! /"'"i : [ OWN BY: ' I ~O_A_TE _ __,_I_NI_TI_A_L-+-_D_A...:.Tt=-...1...:l:..:.Nl...:.TI::._A:::.L--1 .CHKD BY: __ _ OTHER APPROVAL CfTY APPROVAL RV~_D _BY•===c..l . ·- PROJECT NO. RP 92-10 7-/-42 i . DATlt I DRAWINIJ NO. . 332-BL