HomeMy WebLinkAbout1650 SAINT JAMES CT; ; CB972837; PermitB U I L D I N G P E R M I T Permit No: CB972837
Pro1ect No: A970359 3
Development No :
10/30/97 11 :44
Page 1 of 1
Job Address : 1650 ST. JAMES CT Suit 0 :
Permit Type: RESIDENTAL ADD/ALT
Parcel No: 205-060-61-00 Lot#:
Valuation : 41 ,266
Occupancy Group: ReferencP#:
Description : RAD 439 SF, 2ND STORY ABOVE
: GARAGE
Appl/Ownr :
k** Fees
Fees:
Adjustments:
Total Fees :
Fee description
Building Permit
Plan Check
Strong Motion Fee
* BUILDING TOTAL
WILLIAM
En ter "Y" for Plum 1ng I ssue
Enter "Y" for Electric Issue
Enter "Y" for Remodel
A ELECTRICAL TOTAL
Enter 'Y' for Mechanical
760
CITY OF CARLSBAD
Constructi on Type : NEW
Status: ISSUED
Applied : 09/29/97
Apr/Issue : 10/30/97
Entered By: JM
434-0147
.00
236.00
387 .00
Ext fee Data
363 .00
236 .00
4 .00
603.00
N
10 .00 y
10 .00 y
20.00
N
2075 Las Pal.mas Dr., Carlsbad, CA 92009 (619) 438-1161
FOR OFFICE USE ONLY ✓L/-351 r
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
2075 Las Palmas Dr., Carlsbad CA 92009
(760) 438-1161
PLAN CHECK No.flZ837
EST. VAL. i"/ C, 7
Validated By~~~~-hr::o.--l-;,;---.....,---
Date; ______ ----'!:t..!:::::..J,:.4,-...ll:----':._-
1. PROJ~T INFORMATION
L_?.~O S"T.. er:
Address (include Bldg/Suite #I Business Name (at this address)
Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units
9639 09/29/97 0001 01 02
Assessor's Parpel # &r ce lsfv J'i &£cf,f(,ru
Existing Use
/./3 9
Description of Work SO. FT. #of Stories
2. CONTACT PERSON (If different from applicant)
Name Address City State/Zip Telephone# Fax#
3 . APPLICANT O Contractor O Agent for Contractor (iKSwner O Agent for Owner
Name Address City State/Zip Telephone #
4. PROPE'(RTY OWNER .• 1 '6,11 (;;::,,vi:~ :-v c:r
Name Address City State/Zip Telephone #
6. CONTAACTQR • COMPANY NAME
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged
exemption. Any vio ation f Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001).
o "KG" e .,,-,-,,r,.,..,e
Name Address City State/Zip Telephone#
State License # _________ _ License Class _________ _ City Business License # _______ _
Designer Name Address City State/Zip Telephone
State License # _________ _
8. WORKERS' COMPENSATION
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
O I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
O I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are:
Insurance Company _____________________ Policy No. ___________ _ Expiration Date _______ _
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100) OR LESS)
O CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to eecure workers' compensation coverage Is unlawful. and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100,0001, In addition to the cost of compensation. damages as provided for In Section 3706 of the Labor code, interest and attorney's fees.
SIGNATURE.:---:==:::::::-:::-=----===-----=;-:----:;;---:;:;---------:---:-::=:;;;::-DATE --====-:====:
7. OWNER-BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
O I, as owner of the property or my employees with wages as their sole compensation. will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion. the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
u3"' I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(sl licensed
pursuant to the Contractor's License Law).
0 I am exempt under Section ______ Business and Professions Code for this reason:
1. I personally plan_ to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted with the 0following pirson (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
fl ~ ~ D e+-Pv-M1A@1)
4. I plan to provide portions of the work, but I have hired the following person to coordinate. supervise and provide the major work (include name / address / phone
number/ contractors license number):. ______________________________________________ _
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work):. ______________ -:-,,------fl;;ff::----::-------------------+----.------------
PROPERTY OWNER SIGNATURE __ ...;li\/:....;:.....,42 ...... ,.....,_,._:. ___ ,c..A""""'fO:..;:;--W.J<S.,.,,e,,,:....,,_· ,..________ DA TE _ ____.o/LC....7 ..:...2. ... 9'-'/'--'c,,.__..7'---
COMPLETE HIS SECTION FOR NON-RESJDEN77AL BUILDING PERMITS OftL Y
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Accou11t Act? 0 YES O NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES O NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
8. !iONSTRUCTION LENDING AGEt.lCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(il Civil Code).
LENDER'S NAME LENDER'S ADDRESS. ________________________ _
9, APPLICANT CERTIFICATION
I certify that I have read the application and state that the above information Is correct and that the Information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall oxpire by limitation and become null and void if the building or
work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended
or abandoned et any time after the work is mmenced f a perio of 180 days (Section 106.4.4 Uniform Building Code). / /
APPLICANT'S SIGNATURE --• • DATE z: Lk-7' _9 +
WHITE: File YELLOW: Applicant PINK: Finance
PERMIT# CB972837
DESCRIPTION: RAD 439
GARAGE
TYPE: RAD
JOB ADDRESS: 1650
APPLICANT: GANELIN
CONTRACTOR:
OWNER:
CITY OF CARLSBAD
INSPECTION REQUEST
FOR 12/12/97
SF, 2ND STORY ABOVE
ST. JAMES CT
WILLIAM PHONE:
PHONE:
PHONE:
INSPECTOR AREA PY
PLANCK# CB972837
OCC GRP
CONSTR. TYPE NEW
STE: LOT:
760 434-0147
REMARKS: C/GARTH/ AM PLEASE
SPECIAL INSTRUCT:
INSPECTOR / -~,,_ ________ _
TOTAL TIME:
CD LVL DESCRIPTION
19 ST Final Structural
29 PL Final Plumbing
39 EL Final Electrical
49 ME Final Mechanical
ACT COMMENTS
M ~:=-U Q J,,Jr:a.k,_ cJ} ,,y,o >
-i;_
***** INSPECTION HISTORY*****
DATE DESCRIPTION
120197 Interior Lath/Drywall
120197 Gas/Test/Repairs
112697 Frame/Steel/Bolting/Welding
112697 Insulation
112497 Frame/Steel/Bolting/Welding
112497 Rough Electric
111997 Frame/Steel/Bolting/Welding
111997 Shear Panels/HD's
111797 Roof/Reroof
111797 Shear Panels/HD's
111497 Roof/Reroof
111497 Roof/Reroof
111497 Shear Panels/HD's
110697 Ftg/Foundation/Piers
110497 Ftg/Foundation/Piers
ACT
AP
AP
AP
AP
PA
AP
NR
AP
AP
NR
PA
PA
NR
AP
PA
INSP
PY
PY
PY
PY
PY
PY
PY
PY
PY
PY
PY
PY
PY
PY
PY
COMMENTS
BLOCK & NAIL ROOF SHEATH LESS
LESS THAN 24" WIDE
NEED PLAN REVISION
EsGil Corporation
Proftssional Puur. fll.!vi,w 'Enginurs
DATE: 10/28/97
JURISDICTION: Carlsbad
PLAN CHECK NO.: 97-2837
PROJECT ADDRESS: 1650 St James Ct.
PROJECT NAME: Ganelin Residential Addition
SET: II
□ APPLICANT
,eJURIS.
□ PLAN REVIEWER
□ FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
■ The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
■ Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by: ) Fax#:
Mail Telephone Fax In Person
■ REMARKS: Note on the plans that smoke detectors will be provided inside all existing bed
rms, on each floor level and in the hall serving the exisiting bed rms.
By: Chuck Mendenhall
Esgil Corporation
□ GA □ CM □ EJ □ PC 10/24/97
Enclosures:
trnsmtl.dot
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (619) 560-1468 ♦ Fax (619) 560-1576
..
DATE: 10/9/97
JURISDICTION: Carlsbad
PLAN CHECK NO.: 97-2837
EsGil Corporation
Professional Plan !l{,vi,w 'Enginurs
SET:I
PROJECT ADDRESS: 1650 St. James Ct.
PROJECT NAME: Ganelin Residential Addition
D FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department
staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
■ The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
■ The applicant's copy of the check list has been sent to:
Bill Ganelin
1650 St James Ct, Carlsbad, CA 92008
■ Esgil Corporation staff did not advise the applicant (except by mail) that the plan check has
been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted: (by: )
Mail Telephone Fax In Person
0 REMARKS:
By: Chuck Mendenhall
Esgil Corporation
0 GA O CM O EJ O PC 10/2/97
Telephone#:
Fax#:
Enclosures: Energy Forms
trnsmtl.dot
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (619) 560-1468 ♦ Fax (619) 560-1576
..
Carlsbad 97-2837
10/9/97
GENERAL PLAN CORRECTION LIST
JURISDICTION: Carlsbad
PROJECT ADDRESS: 1650 St. James Ct.
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 10/2/97
REVIEWED BY: Chuck Mendenhall
FOREWORD (PLEASE READ):
PLAN CHECK NO.: 97-2837
DATE REVIEW COMPLETED:
10/9/97
This plan review is limited to the technical requirements contained in the Uniform Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and disabled access. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
1. Please make all corrections on the original tracings, as requested in the correction list.
Submit two sets of plans for residential project. For expeditious processing, corrected
sets can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City
of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (619)
438-1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by EsGil
Corporation is complete.
2. To facilitate rechecking, please identify, next to each item, the sheet of the plans
upon which each correction on this sheet has been made and return this sheet
with the revised plans.
3. Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and
Carlsbad 97-2837
10/9/97
where they are located on the plans. Have changes been made not resulting from this
list?
□ Yes □ No
4. Revise note #4 on the cover sheet to indicate 1994 UBC, UMC, UPC and 1993 NEC as
the governing codes.
5. The engineer assuming design responsibility must sign and seal the structural part of the
plans ..
6. Specify on the plans the floor and roof sheathing thickness and type.
7. Specify the roof covering and the exterior siding you intend to use.
8. Detail on the roof framing plan the framing around the dormers.
9. How do you intend to heat the addition. The heating system must be capable of
providing 70° F 3' above the floor per UBC 310.11
10. Note on the plans that smoke detectors will be provided inside all existing bed rms, on
each floor level and in the hall providing access to the bed rms. UBC 310.9.1.2.
11. Submit energy compliance documentation to show that you will comply with the State
energy standards. See the attached energy form CF-1 R and the prescriptive
requirements.
12. Show on the plans the required wall, floor and roof insulation values.
13. Note on the plans that all new windows must be dual glazed per the State energy
standards.
14. The new beam above the garage must be designed for combined floor and roof loads.
The T J beam calc's are for floor loads only.
15. Note on the foundation plan that the hold down anchors must be tied in place prior to
foundation inspection.
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to
perform the plan review for your project. If you have any questions regarding these plan
review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you.
Certificate of Compliance: Residential
Project TIiie
Project Addreaa
Documentation Author Telephone
Compliance Method (Package, Poinl System or Computer) Cllm■teZone
GENERAL INFORMATION
Total Conditioned Floor Area: ____ ft2
Building Type: Single Family Addition
(check one or more) Multi-Family Existing-Plus-Addition
Front Orientation: North I East I South/ West/ All Orientations
(Input orientation in degrees and cirde one.)
· Number of Dwelling Units:
Floor Construction Type: Slab / Raised Floor (circle one or both)
BUILDING SHELL INSULATION
Component Insulation
Type R-Value
Wall ............ ..
Wall ............. .
Roof ........... ..
Roof ........... ..
Floor ........... :.
Floor ........... ..
Slab Edge .. ..
FENESTRATION
Construction
Assembly
U-Value
Location/Comments
(attic, to garage, typical, etc.)
Shading Devices
(Page 1 of 2) CF-1R
Date
Building Permit #
Plan Check/ Date
Field Check/ Dale
Enforcemenl Agency Use Only
Fenestration
Orientation
Area
(sf)
Fenestration
U-Value
Interior
(roller blind, etc.)
Exterior
(shadescreen, etc.)
Overhang . Framing Type
(yes/no) (metal/wood/vinyl)
Front. .... ( )
Front. .... ( )
Left ....... ( )
Left ....... ( )
Rear ..... ( )
Rear ..... ( )
Right. .... ( )
Right.., .. ( .) .
Skylight ...... .
Skylight ..... ..
THERMAL MASS
Type/Covering
(slab/exposed, tile, etc.)
Ravlsed January 1992
Area
(sf)
Thickness
(inches) Location/Description (khchen. bath, etc.)
Certificate of Compliance: Residential (Page 2 of 2) CF-1R
Project TIiie Date
HVAC SYSTEMS
Note: Input h~dronic or combined hydronic data under Water Heating Systems, except Design Heating Load.
Heating Equipment
Type (furnace, heat
pump, etc.)
Cooling Equipment .
Type (air conditioner,
heat pump, evap. cooling)
Minimum
Efficiency
(AFUE/HSPF)
Minimum
. Efficiency
(SEER)
WATER HEATING SYSTEMS
Water Heater
Type
Distribution
Type
Distribution
Type and
Location
(ducts/attic, etc.)
Duct
Location
(attic, etc.)
Number-
in System
Rated1
Input (kW
or Btu/hr)
Duct or
Piping
A-Value
Duct
A-Value
Tank
Capacity
(gallons)
Thermostat
Type
Thermostat
Type
Energy1
Factor or
Recovery
Efficiency
Configuration
(split or package)
Standby1
Loss(%)
External
Tank
Insulation
A-Value
1. Fer small gas storage (rated input,: 75,000 Btu/hr), aleclrlc resistance and heal pump water healers, list Energy Factor: For large gas storage water heaters (rated input~ 75,000 Btu/hr), list Rated lnpu~ Recovery Efficiency and Standby Loss.
For Instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
SPECIAL FEATURES/REMARKS {Add extra sheets if necessary)
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and pertormance specificalions needed to comply with TIiie 24, Parts 1 and 6, of
the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the
individual with overall design responsibility; When this certificate of compliance is submitted for a single building plan to be built in multiple
orientations, any shading feature that is varied is indicated in the Special Features/Remarl<s section.
Designer or Owner (per Business & Professions Coda)
Name:
litle/Firm:
Address:
Telephone: _______________ _
Lie.#:
(signature)
Enforcement Agency
Name:
Title:
Agency:
(date)
Telephone: _______________ _
(signature/stamp)
RevtHd January 1992
(date)
Documentation Author
Name:
Title/Firm:
Address:
Telephone: _______________ _
(signature) (date)
ENERGY REQUIREMENTS FOR RESIDENTIAL ROOM ADDITIONS -CLIMATE ZONE 7
Floor Area of Room Addition
COMPONENT
INSULATION
Ceiling
Wall
Floor
GLAZING (FENESTRATION)
<100 ft2
R-19
R-13
R-13
U-Value1 0.75
% of added floor area ~so sq. ft.
SHADING
THERMAL MASS
n/a
n/a
SPACE HEATING Note 45
(no electric allowed)
If Gas, efficiency=
If Heat Pump:
Split System, efficiency=
Single Package System, eff.=
SPACE COOLING Note'
If Split System, eff.=
If Single Package, eff.=
WATER HEATING Note'
100-499 ft'
R-30
R-13
R-19
0.75
20% + Removed'
. 663
Req. 4
78%AFUE5
6. 8HSPF5
6. 6HSPF'
10. OSEER'
9. 7SEER5
Note'
500-999 ft'
R-30
R-13
R-19
>1000 ft'
R-30
R-13
R-19
0.75 0.75
20% + Removed' 20%
. 663
Req.'
78%AFUE 5
6. 8HSPF'
6. 6HSPF'
10. OSEER'
9. 7SEER5
Note'
. 663
Req.'
78%AFUE5
6. 8HSPF5
6. 6HSPF'
10. OSEER'
9. 7SEER'
Note'
1. Please note that some metal-frame windows may not satisfy the U-value requirement of
0. 75. For additions and alterations only, dual glazed "greenhouse" windows and
skylights may be assumed to meet this requirement.
2. 20% of added floor area plus the area of any glazing removed because of the addition.
3. A coefficient Of 0.66 will be assumed to be provided when dual glazing is used.
4. If the addition will be on top of existing construction, and:
(a)If the addition has conditioned area below all portions, then no thermal mass is
required.
(b) If the addition will be over non-conditioned area (partially or wholly) in a building
mostly of raised-floor construction (after the addition), then thermal mass is required
in the addition (equal to 5% of the area of the addition that is over non-conditioned
space). This may be provided by showing a 2" concrete slab at hearths, countertops,
etc.
(c)If the addition will be over non-conditioned area in a building mostly of slab-on-
grade construction (after the addition), then no thermal mass is required.
If the addition will be at the ground floor, and:
(a)If the addition will be in a building mostly of raised-floor construction (after the
addition), then thermal mass is required in the addition (equal to 5% of the added
conditioned footprint area). This may be provided by showing a 2" concrete slab at
hearths, countertops, etc.
(b) If the addition will be in a building mostly of slab-on-grade construction (after
the addition), then thermal mass is required in the addition (equal to 20% of the added
conditioned slab-on-grade floor area). This may be provided by covering a portion of
the slab-on-grade with tile, wood, etc.
5. If the existing system will be utilized (if no additional systems are needed to provide
UBC heating requirements), there are no special requirents, other than mandatory
insulation for any extended ducts, etc.
6. If the total number of water heaters increases in the residence, then calculations must
be submitted to show that the entire existing-plus-addition system meets the water
heating energy budget.
Carlsbad 97-2837
10/9/97
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 97-2837
PREPARED BY: Chuck Mendenhall
BUILDING ADDRESS: 1650 St. James Ct.
DATE: 10/9/97
BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VN
BUILDING PORTION BUILDING AREA VALUATION VALUE
(ft. 2) MULTIPLIER ($)
addition 439 citv estimate 41,266
Air Conditionina
Fire Sorinklers
TOTAL VALUE 41,266
■ 1991 UBC Building Permit Fee D Bldg. Permit Fee by ordinance: $ 362.50
■ 1991 UBC Plan Check Fee D Plan Check Fee by ordinance: $ 235.63
Type of Review: ■ Complete Review D Structural Only D Hourly
D Repetitive Fee Applicable D Other:
Esgil Plan Review Fee: $ 188.50
Comments:
Sheet 1 of 1
macvalue.doc 5196
City of Carlsbad
■ 4 ■1·11 ,144 ••• ,. I •24-i=I;;, ,14, I I
BUILDING PLANCHECK CHECKLIST
DATE: J 0-6-j' 7 PLANCHECK NO.: CB 97-2.8 5 7
BUILDINGADDRESS: /,6'[0 .St. ,JC<"'taf Ci,
PROJECT DESCRIPTION: __,(<-"-"---P-'--1.:....-_C>c=.::J_c:.,,cl,:.=-'-• ____________ _
ASSESSOR'S PARCEL NUMBER: 2.0 S-:-06 eJ -6 I EST. VALUE: 4 J 2-b £
ENGINEERING DEPARTMENT
APPROVAL DENIAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build.
A Right-of-Way permit is required prior to
construction of the following improvements:
Please see the attached report of deficiencies
marked with □. Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards. Submit corrected plans and/or
specifications to this office for review.
By: Date:
By: _________ Date:
By: ________ Date:
\ FOR OFFICIAL USE ONLY
GINEERING AU'l"HORIZATION TO ISSUE BUILDING PERMIT:
By: ~ Date: lo (,
ENGINEERING DEPT. CONTACT PERSON
Name: David Rick
City of Carlsbad
Dedication Application
Dedication Checklist
Improvement Application
Improvement Checklist
Address: 2075 Las Pal mas Dr., Carlsbad, CA 92009
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
Right-of-Way Permit Application
Right-of-Way Permit Submittal Checklist
and Information Sheet
Sewer Fee Information Sheet
Phone: (619) 438-1161, ext. 4324
CFD INFORMATION
Parcel Map No:
Lots:
Recordation:
Carlsbad Tract:
\lt.ASPALMAS\SYS\LIBRARY\ENGI\NOBO\DOCS\CHKL§T)Bujldfnp Plancl!otl Ckl§I APQQQ] Fonn PR doc ,.
A-4
"'""""2075 Las Palmas Dr.• Carlsbad, CA 92009-1576 • (619) 438-1161 • FAX (619) 438-0894
~~ND✓
□
□
□ □ □
□ □ □
BUILDING PLANCHECK CHECKLIST
SITE PLAN
1. Provide a fully dimensioned site plan drawn to scale. Show:
A. North Arrow D. Property Lines
B. Existing & Proposed Structures E. Easements
C. Existing Street Improvements F. Right-of-Way Width & Adjacent Streets
G. Driveway widths
2. Show on site plan:
A. Drainage Patterns
1. Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course.
2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building."
B. Existing & Proposed Slopes and Topography
3. Include on title sheet:
A. Site address
B. Assessor's Parcel Number
C. Legal Description
For commercial/industrial buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
DISCRETIONARY APPROVAL COMPLIANCE
4a. Project does not comply with the following Engineering Conditions of approval for Project No. ________________________ _
4b. All conditions are in compliance. Date: __________ _
~S~~S\SYS'J..IBRARV\ENG\WORD\OOCS\CHKLST\Bulklillg Plancheck Cklsl BP0001 Fonn OR.doe 2
--------------··.
1 ST✓
□
□
□
□ □
□ □
BUILDING PLANCHECK CHECKLIST
DEDICATION REQUIREMENTS
5. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $ ______ , pursuant to Carlsbad
Municipal Code Section 18.40.030.
Dedication required as follows: __________________ _
Dedication required. Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 ½" x 11" plat map
and submit with a title report. All easement documents must be approved and
signed by owner(s) prior to issuance of Building Permit. Attached please find an
application form and submittal checklist for the dedication process. Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person. Applications will not be accept by mail or fax.
Dedication completed by: ___________ _ Date: ____ _
IMPROVEMENT REQUIREMENTS
6a. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $, _______ , pursuant to Carlsbad Municipal Code
Section 18.40.040.
Public improvements required as follows: ______________ _
Attached please find an application form and submittal checklist for the public
improvement requirements. A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process. The completed application form and the requirements on the
checklist must be submitted in person. Applications by mail or fax are not
accepted. Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit.
Improvement Plans signed by: ------'-------Date: ____ _
6b. Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or
current grant deed on the property and processing fee of$. ________ so
we may prepare the necessary Future Improvement Agreement. This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit.
Future public improvements required as follows:
\\l.ASPALMAS\SYS\L!BRARY\ENG\WORDIDOCS\CHKLST\Building Plancheck CIils\ BP0001 Fo,m DR.doc
Rev 913197 3
0 0
0 0
0 0
0 0
0 0
0 0
0
0
0
0
0
0
0
BUILDING PLANCHECK CHECKLIST
6c. Enclosed please find your Future Improvement Agreement. Please return
agreement signed and notarized to the Engineering Department.
Future Improvement Agreement completed by:
Date:
6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective
improvements found adjacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11.06.030 of the Municipal Code.
7a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export). Write
"No Grading" on plot plan if none is required.
7b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached. NOTE: The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit.
Grading Inspector sign off by: Date: -----------
7c. Graded Pad Certification required. (Note: Pad certification may be required even
if a grading permit is not required.)
7d. No Grading Permit required.
7e. If grading is not required, write "No Grading" on plot plan.
MISCELLANEOUS PERMITS
8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are
not limited to: street improvements, tree trimming, driveway construction, tieing
into public storm drain, sewer and water utilities.
Right-of-Way permit required for:
~.S~~S\SYS\LIBRARV\ENG\WORO\OOCSICHKLST\Bulldir-.g Plancheok Cklst BP0001 Form OR.doc 4
1st✓
□
□ □ □
□ □
□
□ □ □
BUILDING PLANCHECK CHECKLIST
9. A SEWER PERMIT is required concurrent with the building permit issuance. The
fee is noted in the fees section on the following page.
10. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension 153, for
assistance.
Industrial Waste permit accepted by:
Date:
11. NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit. The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas. Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first.
12. □ i;r.;"quired fees are attached ii" N~ fees required
13. Additional Comments:
\'LASPALMAS\SYSILl8RARY\ENGIWORDIOOCSICHKLST'8uildlng Plancheck Ckl:sl 8P0001 Form DR.doc
Rev. 913/97 5
□□
rµ□ □
\
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST . ~-
Plan Check Nf?·pCB °I l ,;J, B~ 0 Address lb ~o 1 ✓ JAdif J Uq!f_
Planner x;:% 7,, ~ V\.., Phone (619) 438-1161 , extension L/ s .:2.8
APN: ')--o ') -D(..o · /o I
Type of Project and Use: zfl--: Project Density: ______ ..,.... __
Zoning: ~-I General Plan: /[CM Facilities Management Zone:_,./ __ _
CFD fin/l;Rrll ~ __ ,Date of participation: ____ Remaining net dev acres: __ _
Circl~
lFor non-residential development: Type of land used created by
this permit: ____________________ )
Legend: ~ Item Complete (QJ Item Incomplete -Needs your action
Environmental Review Re_q_u_ir-ed_: -Y-ES-~~~NO J2_ TYPE
DATE OF COMPLETION: /
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES NO TYPE ----
APPROVAL/RESO. NO. _____ DATE ___ _
PROJECT NO. _______ _
OTHER RELATED CASES: __________________ _
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval: _______________________ _
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES
CA Coastal Commission Authority? YES
If California Coastal Commission Authority: Contact them at -3111
200, San Diego CA 92108-1725; (619) 521-8036
Determine status (Coastal Permit Required or Exempt):
Camino Del Rio North, Suite
Coastal Permit Determination Form already completed? YES NO
If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log #:
Follow-Up Actions:
1) Stamp Building Plans as uExempt" or "Coastal Permit Required" (at minimum
Floor Plans).
2) Complete Coastal Permit Determination Log as needed.
t1;D □
!
□
□
lnclusionary Housing Fee required: YES N~
!Effective date of lnclusionary Housing Ordinance -May 21, 1993.) .,/.._.,.._
Data Entry Completed? YES NO
(Enter CB#; UACT; NEXT12; Construct housing Y/N; Enter Fee Amount (See fee schedule for amount): Return)
Site Plan:
1. Provide a fully dimensional site plan drawn to scale. Show: North arrow,
property lines, easements, existing and proposed structures, streets, existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines.
2. Provide legal description of property and assessor's parcel number.
Zoning:
1. Setbacks:
Front:
Interior Side: ?r'/J,1 I : . Required Shown '7V
Required __ :_']'--•---Shown ==~=(=,)==' ===== ' Street Side: Required Shown -------Rear: Required I '--1 1 Shown __ 2L...,/c......:..'-/_' __
~□ □ 2. Accessory structure setbacks:
Front:
----
oa-c,;ired Shown
~□□
Qi □□
qb □ □
Interior Side:
Street Sid ·
Rear·
ructure separation:
3. Lot Coverage:
4. Height:
------Required _____ _
Required _____ _
Required ______ _
Required _____ _
Required _k_<fi .... ~_;.::.o __
Required -~~=L_=·c...,,:.3_0_' _
5. Parking: Spaces Required _ __.:,;;;;-:::.._ __ _
Guest Spaces Required ___ ---___ _
-------Shown -------Shown -------Shown -------Shown -------
Shown ~l-~_O__,_o/c_D __
~( Shown """'IQ ---',::c__""------
Shown -------
Shown -------
D O O Additional Comments _______________________ _
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTE
---------------... ··-··•···